IN ORDER TO AVOID ELECTRIC SHOCK OR OTHER POSSIBLE INJURY:
• DO NOT USE THIS PRODUCT FOR HUMAN SAFETY APPLICATIONS.
IT WAS NOT DESIGNED, TESTED OR RECOMMENDED FOR THIS
USE.
• DO NOT USE THIS PRODUCT IN HAZARDOUS LOCATIONS (E.G.
EXPLOSIVE ATMOSPHERES). IT WAS NOT DESIGNED, TESTED OR
RECOMMENDED FOR THIS USE.
• ENSURE THE PRODUCT IS PROPERLY WIRED TO THE CORRECT
POWER SUPLLY FOR THE APPLICATION. REFER TO THE
SPECIFICATIONS AND WIRING DIAGRAMS IN THIS MANUAL.
MODELS COVERED IN THIS MANUAL
E56BAL70UAA01
P51894 Rev 03
Effective: 18 June 2009 Page 1
Installation Instructions
E56 Pancake Style Inductive Proximity Sensor
WARNING
Questions? Call our Sensor Application Engineers at (800) 426-9184.
Note: This installation manual only covers small-diameter
pancake models (with model numbers beginning with
E56A). For the installation manual covering medium- and
large-diameter models, use P51895.
INTRODUCTION
The Cutler-Hammer E56 Pancake Style Inductive Sensor from
Eaton is a top-sensing, solid-state device used to detect metal
targets at range.
The E56 Series is available in three different sizes: small (ø 74
mm), medium (ø 96 mm), and large (ø 152 mm). Connectivity
options include a factory-installed Mini Connector, Micro
Connector or Screw Terminals. The E56 Series meets the
requirements of NEMA Type 4, 4X, 6, 6P, 12 and 13 enclosures.
Each package style is available in either 4-wire DC or 2-wire
AC/DC versions. Additional key features include complementary
outputs (1NO / 1NC) for DC models and two output status LEDs.
The 4-wire DC models also feature Auto-Confi g Outputs, which
automatically set the sensor to the correct output mode (NPN/
sinking or PNP/sourcing) without user intervention.
BASIC OPERATION
Inductive proximity sensors generate a high frequency
oscillating magnetic fi eld in the vicinity of the sensing head.
When a metal object enters this fi eld, it changes the fi eld
loading of the oscillator coil. This change is recognized by a
detector circuit, which then energizes the output.
E56 Series sensors will detect all metals, but primarily steel. The
exact distance at which a target is detected is determined by its
size, thickness and type of metal.
To determine sensing distance with your target, see the Sensing
Field Diagrams on Page 2. These diagrams serve as a reference
point and show where the target will be detected for lateral
(side or slide-by) and axial (head-on) approaches. These curves
must be corrected for smaller-than-standard targets and other
metals. (Standard target sizes are listed Page 2.)
Product Family
E56 E56 Series
Size
A Baseplate: 80 mm
Sensing Head: ø 74 mm
B Baseplate: 110 mm
Sensing Head: ø 96 mm
C Baseplate: 170 mm
Sensing Head: ø 152 mm
Voltage Type
A AC/DC 2-wire
D DC 4-wire
Output Type
L1 N.O. / 1 N.C.
M1 N.O.
N1 N.C.
Sensing Range
40 40 mm
50 50 mm
60 60 mm
70 70 mm
100 100 mm
Shielding
U Unshielded
S Shielded
Output Mode
A Auto-Confi g (NPN/PNP)
N NPN
P PNP
Connection
A01 AC Micro, 3-Pin
B01 AC Mini, 3-Pin
C02 Cable, 2 m
D01 DC Micro, 4-Pin
E01 DC Mini, 4-Pin
Screw Terminals
Note: Not all possible combinations
shown in table are offered as standard.