7526J1660 SPECIFICATION CONTROL DRAWING CHEMINAX 75 OHM, AWG 26, 19 STRANDS OF AWG 38, DATA BUS CABLE, OUTER SPACE USE Date 7-24-09 Revision E THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE DESIGNATED. .0190 .039 .003 CONDUCTOR AWG 26, 19 Strands of AWG 38, Silver-Coated Ultra High Strength Copper Alloy DIELECTRIC Radiation-Crosslinked, Modified ETFE Color - Light Blue/White ELECTRICAL CHARACTERISTICS CHARACTERISTIC IMPEDANCE 75 5 ohms, Method C at 1 MHz MUTUAL CAPACITANCE 30.0 pF/ft. (maximum) ATTENUATION 1.5 dB/100 ft. (maximum) at 1 MHz (300 ft. sample length minimum) ADDITIONAL REQUIREMENTS COMPONENT WIRE PRIOR TO CABLING (Test Procedures per SAE AS22759) CROSSLINK PROOF INSULATION (DIELECTRIC) ELONGATION TENSILE STRENGTH INSULATION FLAWS SPARK TEST IMPULSE TEST INSULATION RESISTANCE LOW TEMPERATURE-COLD BEND .095 .005 SHIELD AWG 38, Silver-Coated Copper SHRINKAGE 300 3C for 1 hour, .500 inch mandrel, .375 lb., 2.5 kV dielectric test 50% (minimum) 5000 lbf/in2 (minimum) 3.0 kV (rms) 8.0 kV (peak) 5000 megohms for 1000 ft. (minimum) -65 2C for 4 hours, .500 inch mandrel, .500 lb., 2.5 kV dielectric test 200 3C for 1 hour, .125 inch (maximum) in 12 inches FINISHED CABLE (Test Procedures per NEMA WC 27500, unless otherwise specified) .111 .005 JACKET Radiation-Crosslinked, Modified ETFE BLOCKING CROSSLINKED VERIFICATION FLAMMABILITY (Method B of Spec 1200) JACKET ELONGATION TENSILE STRENGTH JACKET FLAWS SPARK TEST IMPULSE TEST JACKET THICKNESS LOW TEMPERATURE-COLD BEND SHIELD COVERAGE VOLTAGE WITHSTAND (DIELECTRIC) WEIGHT 200C for 6 hours 300 5C for 6 hours, 3.00 inch mandrel 3 seconds (maximum); 3 inch (maximum); no flaming of facial tissue 50% (minimum) 5000 lbf/in2 (minimum) 1.0 kV (rms) 6.0 kV (peak) .008 inch (nominal) -55 5C for 4 hours, 3.00 inch mandrel 90% (minimum) 1500 volts (rms) 11.4 lbs/1000 ft. (maximum) OUTER SPACE REQUIREMENTS RADIATION RESISTANCE Outer jacket color will be white (designated by a "-9" appended to the part number, e.g. 7526J1660-9) unless otherwise specified. Designate outer jacket color with a dash number in accordance with MIL-STD-681. Other codes and suffixes may be added to the part number, as necessary, to capture any additional requirements imposed by the purchase order. VACUUM STABILITY TOTAL MASS LOSS (TML) VOLATILE CONDENSABLE MATERIAL (VCM) WEIGHT LOSS: (Test per Spec 55/) 500 megarads/3.25 inch mandrel 1.0 kV dielectric test 1.00% (maximum) 0.10% (maximum) 0.45% (maximum) Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. Page 1 of 1 The TE logo, Tyco Electronics, Cheminax and Raychem are trademarks. Raychem Wire & Cable 501 Oakside Avenue Redwood City, California 94063-3800 1-800-227-8816 Fax: 1-650-361-6297 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. (c) 2006-2009 Tyco Electronics Corporation. All rights reserved.