Signal converters Index P su owe pp r lie s 12 - Signal and data converters General information...................................................................................................................12.1 Analog signal converters........................................ 12.3 - 12.26 Features and benefits...........................................................................................................12.3 Application, approvals and marks.........................................................................................12.4 Overview.....................................................................................................................12.5 - 12.6 Ordering details........................................................................................................12.7 - 12.10 Approximate dimensions....................................................................................................12.11 Technical data.........................................................................................................12.12 - 12.24 Technical diagrams, connection diagrams, approximate dimensions...................................12.25 Signal data converters.......................................... 12.27 - 12.44 General information.............................................................................................................12.27 Overview.............................................................................................................................12.28 Ordering details table..........................................................................................................12.29 Benefits and advantages....................................................................................................12.30 Ordering details..................................................................................................................12.31 Approximate dimensions........................................................................................12.32 - 12.34 Technical data.........................................................................................................12.35 - 12.44 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12 12.A 1SXU000023C0202 Rev. A r we ies o P pl p su Notes 12 12.B 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Signal and data Converters Signal and data converters Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn al co nv er te rs Nowadays various types of data transmission and interfaces are used in control processes. Nearly every process includes a control system that receives data either by means of analog signals or by data transmission. The data is then evaluated and the appropriate parameters are set. A reliable process control essentially depends on the faultless, untroubled and secure transmission and processing of these analog signals. There may however, arise numerous problems which can disturb or even block an ideal process sequence. The serial data converters from ABB allow the establishment of a communication between units with different communication 12 standards. ABB's range of analog signal converters are ideally suited when existing electrical or physical values have to be converted into proportional standard signals or relay threshold signals. Besides the conversion of signals, analog signal converters and serial data converters are suited for the amplification, filtering or separation of analog signals. In order to assure the process continuity, existing systems consistently have to be updated or connected to new devices. If the communication standard of the existing system and the connected device are different, serial data converters make the establishment of the communication possible. 12.1 1SXU000023C0202 Rev. A rs te er nv a gn Si o lc 12 12.2 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Analog signal converters Si gn al co nv er te rs Product range for analog signal processing CC-U range CC-E range * 8 different standard signal outputs on one device * Universally configurable devices and single-function devices * Input and output side universally configurable Analog signal Converters * Also available with 2 threshold relay outputs Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage * Adjustment and operating elements on the front side * Safe operation by electrical 3-way isolation * Plug-in connecting terminals, unambiguously and clearly m arked Conversion, measurement and separation of * Standard signals * Signals of RTD sensors (PT10, PT100, PT1000) * Thermocouple signals * Adjustment and operating elements on the front side * Safe operation by electrical 3-way isolation * Unambiguous and clear connecting terminal markings Conversion, measurement and separation of * Standard signals (0-5 V, 0-10 V, 0-20 mA, 4-20 mA) * Temperature signals of RTD sensors (PT 100) * Thermocouple signals (types J and K) * Current measurement signals (0-5 A, 0-20 A AC/ DC) * TRMS values of currents and voltages Characteristics of single-function devices Characteristics * No adjustment or balancing necessary. * The required input and output ranges can be configured for all devices by means of directly accessible DIP switches positioned on the side. Characteristics of universal devices * Due to the wide input range of the gain and offset stages all input signals between the minimum and the maximum input value can be universally converted to all common output signals. * Devices for DC or AC (50/60 Hz) supply available. * The required input and output ranges can be configured by means of directly accessible DIP switches positioned on the side * Gain adjustment of 5 % by means of an adjustment potentiometer on the front-side * Offset adjustment of 5 % by means of adjustment potentiometers on the front-side 12.3 1SXU000023C0202 Rev. A 12 rs te er nv na g Si o lc Analog signal converters Application, approvals and marks Applications for analog signal processing and correct solution using CC-E and CC-U converters 0-10 V Nearly every process includes a control system that receives data by means of analog signals and then evaluates the data and sets the respective parameters correspondingly. 0-10 V Controller e.g. AC500 1. Analog signal converter (e.g. CC-E or CC-U) When transmitting analog signals numerous problems may arise which can disturb or even block an ideal behavior of the process. Below we have listed some processing problems together with the respective solutions to solve these problems: 100 m 2. Analog signal converter (e.g. CC-E or CC-U) 0-20 mA 100 m Signal conversion 4-20 mA Actuator Sometimes the available signals cannot be processed by the controller or the actuator. In this case, signal converters are required to convert the input signal (or different input signals) to the desired output signal. Measuring sensor Signal amplification 2CDC 282 013 F0206 If long lines or high burdens have to be operated, it may be necessary to amplify the signal. CC analog signal converters require only low input power and provide high output power. Thus, there are no restrictions for the converter's position on the line, i.e. it can be used Signal separation * for signal refreshing at the end of the line (low input power) Protection against overvoltage The increased use of micro-electronics make controls much more sensitive against overvoltages, resulting from lightning discharges or switching processes. Suppression diodes are incorporated in the input of the CC analog signal converters which enable the converters to arrest overvoltages with low energy level (resulting from switching processes) by themselves. The products furthermore provide electrical isolation between input, output and supply circuit for protection of the controller connected to the output. * or for signal amplification at the beginning of the line (high output power). Signal filtering Protection against ground loops If components are used which refer to ground, the measuring signals can be falsified by a so-called ground loop. In this case, certain parts of the signal are transmitted via earth and not via the analog transmission line, thus causing incorrect evaluation of the signal. The electrical isolation between the input and the output disconnects these ground loops and thus enables correct signal transmission. J J J G J J J J A UL 1604 (Class I, Div 2, hazardous locations), CAN/CSA C22.2 No.213 G K CB scheme J J J E CCC J J J J CC-U/V J UL 508, CAN/CSA C22.2 No.14 CC-U/I CC-E/I J A Approvals CC-E IAC/ILPO CC-U/TCR J CC-U/TC G CC-E/TC CC-U/RTD J CC-U/RTDR CC-E/RTD J CC-U/STD J CC-E I/I CC-U/STDR J existing G existing for some devices j pending CC-E/STD 12 Particularly on long lines or in rough industrial environments the signals are exposed to high electromagnetic interferences. The frequency of the coupled interference signals may be in the range of the common mains frequency (50 Hz) or even much higher (in case of frequency converters). According to the specific requirements, analog signal converters are available which provide reliable suppression of those interferences by means of an input low-pass filter. J J J J J G Marks a CE J J J J J J J J J J J J J J b C-Tick J J J J J J J J J J J J J J 12.4 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Analog signal converters Overview Si gn al co nv er te rs CC-E/STD analog signal converter with 3-way electrical isolation * 2 universally configurable devices (type CC-E/STD) * 2x10 single-function devices *"Plug and Work", no adjustment of single-function devices required Loop-powered current/current isolator without external power supply for analog current signals of 0-20 mA and 4-20 mA * Electrical isolation between input and output * Very low internal voltage drop 2.5 V * Available with one or two independent channels * Width only 18 mm (1 and 2 channels) CC-U/STD universal signal converter with 3-way electrical isolation * More than 120 configurations possible * Configurable output signal response on input voltage signal interruption (low fail safe / high fail safe) * Adjustment and operating elements on the front * Short-circuit proof signal outputs * Plug-i connecting terminals for inputs, outputs and supply * Very fast signal transmission enables use in control systems CC-U/STDR universal signal converter for standard signals, with 2 threshold relay outputs and with 3-way electrical isolation * Standard signal converter with 7 setting ranges * 2 threshold relay outputs with one c/o contact each (threshold and respective hysteresis can be adjusted independently from each other) * Open-circuit or closed-circuit principle configurable by means of a DIP switch * 2 yellow LEDs for clear status indication of the output relays * Plug-in connecting terminals for inputs, outputs and supply 12 CC-E/RTD temperature signal converter for RTD sensors, linearized with 3-way electrical isolation * 2 universally configurable devices (type CC-E/RTD) * 2x12 single-function devices * Plug and Work", no adjustment of single-function devices required * Temperature signal converter for PT100 sensors * 2- or 3-wire connection CC-U/RTD universal signal converter for PT10, PT100, PT1000 temperature sensors (acc. to IEC 751 and JIS C 16041), linearized with 3-way electrical isolation * Configurable output signal response on input signal interruption (low / high fail safe) * Adjustment and operating elements on the front-side * Short-circuit proof signal outputs * Plug-in connecting terminals for inputs, outputs and supply * 2- or 3-wire connection CC-U/RTDR universal signal converter for temperature and resistance signals, with 2 threshold relay outputs and 3-way electrical isolation * Temperature signal converter for PT100 signals (5 ranges up to 800 C) and variable resistances from 0-380 q * 2 threshold relay outputs with one c/o contact each (threshold and respective hysteresis can be adjusted independently from each other) * Open-circuit or closed-circuit principle configurable by means of a DIP switch * 2 yellow LEDs for clear status indication of the output relays * Plug-in connecting terminals for inputs, outputs and supply * 2- or 3-wire connection Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12.5 1SXU000023C0202 Rev. A rs te er nv na g Si o lc Analog signal converters Overview CC-E/TC analog signal converter for thermocouple signals of the types J and K with 3-way electrical isolation * 2 universally configurable devices (type CC-E/TC) * 2x6 single-function devices *"Plug and Work", no adjustment of single-function devices required CC-U/TC universal signal converter for thermocouples with 3-way electrical isolation * Temperature signal converter for thermo-couples of the types K, J, T, S, E, N, R, B * Continuously adjustable voltage signal input 0-10 mV and 0-50 mV * Differential temperature meas. possible 1) * Configurable output signal response on input signal interruption (low fail safe / high fail safe) * Adjustment and operating elements on the front-side * Short-circuit proof signal outputs * Plug-in connecting terminals for inputs, outputs and supply CC-U/TCR universal signal converter for thermocouples, with 2 threshold relay outputs and 3-way electrical isolation * Temperature signal converter for thermocouples of the types K, J, T, S * 2 threshold relay outputs with one change-over contact each (threshold and respective hysteresis can be adjusted independently from each other) * Open-circuit or closed-circuit principle configurable by means of a DIP switch * 2 yellow LEDs for clear status indication of the output relays * Plug-in connecting terminals for inputs, outputs and supply CC-E/I measuring converter for current signals 0-5 A, 0-20 A, AC/DC with 3-way electrical isolation 12 * 2 universally configurable devices (type CC-E/I) * 2x6 single-function devices *"Plug and Work", no adjustment of single-function devices required CC-E IAC/ILPO measuring converter without auxiliary power for sinusoidal currents 0-1 A, 0-5 A, output 4-20 mA * Measuring converter for sinusoidal currents (0-1 A, 0-5 A) * Measuring range selection by front-face sliding switch * 4-20 mA output current in proportion to input current * no additional power supply required CC-U/I universal measuring converter for RMS values of 0-1 A and 0-5 A, with 3-way electrical isolation * RMS converter for current signals up to 1 A and up to 5 A of any wave form (DC, DC with superimposed AC components, pure sinusoidal, triangular, phase-angle controlled, etc. in a measuring range of 0-600 Hz) * Adjustment and operating elements on the front * Short-circuit proof signal outputs * Plug-in connecting terminals for inputs, outputs and supply CC-U/V universal measuring converter for RMS values of 0-600 V, with 3-way electrical isolation * RMS converter for voltage signals up to 600 V of any wave form (DC, DC with superimposed AC components, pure sinusoidal, triangular, phase-angle controlled, etc. in a measuring range of 0-600 Hz) * Adjustment and operating elements on the front * Short-circuit proof signal outputs * Plug-in connecting terminals for inputs, outputs and supply 12.6 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Standard signal converter Ordering details al co nv er te rs Description Standard signal converters of the CC-E range are designed to convert all kind of input standard signals (V, mA) into output standard signals (V, mA). Standard signal converters Supply voltage range 24 V DC CC-E/I Input signal Output signal 0-5 V, 0-10 V 0-5 V, 0-10 V 0-20 mA, 0-20 mA, 4-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA -10...+10 V CC-E V/V 110-240 V AC CC-E I/I-2 loop powered CC-E/STD1) 3) 1SVR011700R0000 0.088 (0.194) CC-E V/V 1SVR011710R2100 0.083 (0.183) CC-E V/I 1SVR011711R1600 0.084 (0.185) 4-20 mA CC-E V/I 1SVR011712R1700 0.084 (0.187) 0-10 V CC-E I/V 1SVR011713R1000 0.082 (0.181) 0-20 mA CC-E I/I 1SVR011714R1100 0.084 (0.187) 4-20 mA CC-E I/I 1SVR011715R1200 0.084 (0.185) 0-10 V CC-E I/V 1SVR011716R1300 0.084 (0.185) 0-20 mA CC-E I/I 1SVR011717R1400 4-20 mA CC-E I/I 1SVR011718R2500 0.084 (0.187) -10...+10 V CC-E V/V 1SVR011719R2600 0.082 (0.181) CC-E/STD 3) 1SVR011705R2100 0.090 (0.198) 0-5 V, 0-10 V 0-20 mA, 4-20 mA 4-20 mA Weight (1 pce) kg (lb) 0-10 V 0-5 V, 0-10 V 0-20 mA Catalog number 0-20 mA 0-20 mA, 4-20 mA 0-10 V Type 0-10 V CC-E V/V 1SVR011720R2300 0.096 (0.212) 0-20 mA CC-E V/I 1SVR011721R1000 0.087 (0.192) 4-20 mA CC-E V/I 1SVR011722R1100 0.091 (0.200) 0-10 V CC-E V/V 1SVR011723R1200 0.091 (0.200) 0-20 mA CC-E V/I 1SVR011724R1300 0.088 (0.194) 4-20 mA CC-E V/I 1SVR011725R1400 0-10 V CC-E V/V 1SVR011726R1500 0.096 (0.212) 0-20 mA CC-E V/I 1SVR011727R1600 0.087 (0.192) 4-20 mA CC-E V/I 1SVR011728R2700 0.088 (0.194) -10...+10 V -10...+10 V CC-E V/V 1SVR011729R2000 0.086 (0.190) 0-20 mA, 4-20 mA 0-20 mA, 4-20 mA CC-E I/I-12) 1SVR010200R1600 0.038 (0.084) CC-E I/I-22) 1SVR010201R0300 0.044 (0.097) CC-U/STD 1SVR040000R1700 0.125 (0.276) 1SVR040001R0400 0.126 (0.278) 1SVR040010R0000 0.142 (0.313) 24-48 V DC, 110-240 V AC, 100-300 V DC, refer to table refer to table 2 c/o 24 V AC CC-U/STDR4) 1SVR040011R2500 CC-U/STD 1) 1604 Class I, Div.2 (universal device) 2) CC-E-I/I-1 has 1 channel, CC-E-I/I-1 3) 3-way electrical isolation 4) with relay output Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage has 2 channels 12.7 1SXU000023C0202 Rev. A 12 rs te er nv na g Si o lc Temperature signal converters Ordering details RTD Converters Supply voltage range Input signal Output signal Type 24 V DC refer to table 0-10 V, 0-20 mA, 4-20 mA CC-E/RTD 1) PT100 0...100 C PT100 -50...+50 C CC-E/RTD PT100 0...300 C PT100 -50...+250 C 110-240 V AC refer to table PT100 0...100 C CC-U/RTD 12 PT100 -50...+50 C PT100 0...300 C PT100 -50...+250 C Catalog number Weight (1 pce) kg (lb) 1SVR011701R2500 0.091 (0.200) 0-10 V CC-E RTD/V 1SVR011730R2500 0.084 (0.185) 0-20 mA CC-E RTD/I 1SVR011731R1200 0.086 (0.190) 4-20 mA CC-E RTD/I 1SVR011732R1300 0-10 V CC-E RTD/V 1SVR011733R1400 0.083 (0.183) 0-20 mA CC-E RTD/I 1SVR011734R1500 0.084 (0.185) 4-20 mA CC-E RTD/I 1SVR011735R1600 0.084 (0.187) 0-10 V CC-E RTD/V 1SVR011736R1700 0.084 (0.185) 0-20 mA CC-E RTD/I 1SVR011737R1000 0.084 (0.187) 4-20 mA CC-E RTD/I 1SVR011738R2100 0.101 0-10 V CC-E RTD/V 1SVR011739R2200 0.084 (0.185) 0-20 mA CC-E RTD/I 1SVR011740R0700 0.084 (0.187) 4-20 mA CC-E RTD/I 1SVR011741R2400 0-10 V, 0-20 mA, 4-20 mA CC-E/RTD 1SVR011706R2200 0.093 (0.205) 0-10 V CC-E RTD/V 1SVR011788R2400 0.086 (0.190) 0-20 mA CC-E RTD/I 1SVR011789R2500 0.088 (0.194) 4-20 mA CC-E RTD/I 1SVR011790R2200 0.089 (0.196) 0-10 V CC-E RTD/V 1SVR011791R1700 0.087 (0.192) 0-20 mA CC-E RTD/I 1SVR011792R1000 0.089 (0.196) 4-20 mA CC-E RTD/I 1SVR011793R1100 0-10 V CC-E RTD/V 1SVR011794R1200 0.087 (0.192) 0-20 mA CC-E RTD/I 1SVR011795R1300 0.089 (0.196) 4-20 mA CC-E RTD/I 1SVR011796R1400 0-10 V CC-E RTD/V 1SVR011797R1500 0.086 (0.190) 0-20 mA CC-E RTD/I 1SVR011798R2600 0.089 (0.196) 4-20 mA CC-E RTD/I 1SVR011799R2700 0.088 (0.194) refer to table 2 c/o CC-U/RTD 1SVR040002R0500 0.126 (0.278) 1SVR040003R0600 0.128 (0.282) 1SVR040012R2600 0.146 (0.322) 1SVR040013R2700 0.148 (0.326) 24-48 V DC, 100-300 V DC, 110-240 V AC, 24 V AC refer to table CC-U/RTDR 3) 1) 1604 Class I, Div.2 (universal device) 2) CC-E-i/i-1 has 1 channel; CC-E-1/1-1 has 2 channels 3) with relay output 12.8 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Thermocouple converters Ordering details al co nv er te rs Thermocouple converters Supply voltage range 24 V DC Output signal Type thermocouple types J and K type J 0...600 C 0-10 V, 0-20 mA, 4-20 mA CC-E/TC1) 1SVR011702R2600 0.089 (0.196) 0-10 V CC-E TC/V 1SVR011750R0100 0.087 (0.192) 0-20 mA CC-E TC/I 1SVR011751R2600 0.084 (0.187) 4-20 mA CC-E TC/I 1SVR011752R2700 0.102 0-10 V CC-E TC/V 1SVR011753R2000 0.084 (0.185) type K 0...1000 C CC-E TC 110-240 V AC Catalog number Weight (1 pce) kg (lb) Input signal 0-20 mA CC-E TC/I 1SVR011754R2100 4-20 mA CC-E TC/I 1SVR011755R2200 0.086 (0.190) thermocouple types J and K 0-10 V, 0-20 mA, 4-20 mA CC-E/TC 1SVR011707R2300 0.088 (0.194) type J 0...600 C 0-10 V CC-E TC/V 1SVR011760R0300 0.084 (0.187) 0-20 mA CC-E TC/I 1SVR011761R2000 0.088 (0.194) 4-20 mA CC-E TC/I 1SVR011762R2100 0.1 (0.220) 0-10 V CC-E TC/V 1SVR011763R2200 0.086 (0.190) 0-20 mA CC-E TC/I 1SVR011764R2300 0.088 (0.194) 4-20 mA CC-E TC/I 1SVR011765R2400 0.086 (0.190) CC-U/TC 1SVR040004R0700 0.130 (0.287) 1SVR040005R0000 0.128 (0.282) CC-U/TCR 1) 1SVR040014R2000 0.145 (0.320) type K 0...1000 C 24-48 V DC, 100-300 V DC, 110-240 V AC, 24 V AC refer to table refer to table 2 c/o 1SVR040015R2100 1) with relay output Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12.9 1SXU000023C0202 Rev. A 12 rs te er nv na g Si o lc Measuring converters Ordering details Measuring converters Supply voltage range 24 V DC CC-E IAC/ILPO Output signal Type 0-5 A, 0-20 A, AC/DC 0-10 V, 0-20 mA, 4-20 mA CC-E/I 1) 1SVR011703R2700 0.096 (0.212) 0-10 V CC-E IAC/V 1) 1SVR011770R0500 0.090 (0.198) 0-20 mA CC-E IAC/I 1) 1SVR011771R2200 4-20 mA CC-E IAC/I 1) 1SVR011772R2300 0-10 V CC-E IDC/V 1) 1SVR011773R2400 0.092 (0.207) 0-20 mA CC-E IDC/I 1) 1SVR011774R2500 0.091 (0.200) 4-20 mA CC-E IDC/I 1) 1SVR011775R2600 0.093 (0.205) 0-10 V, 0-20 mA, 4-20 mA CC-E/I 1) 1SVR011708R0400 0.099 (0.218) 0-10 V CC-E IAC/V 1) 1SVR011780R1100 0.092 (0.203) 0-20 mA CC-E IAC/I 1) 1SVR011781R0600 0.092 (0.207) 4-20 mA CC-E IAC/I 1) 1SVR011782R0700 0.095 (0.209) 0-10 V CC-E IDC/V 1) 1SVR011783R0000 0.093 (0.205) 0-20 mA CC-E IDC/I 1) 1SVR011784R0100 4-20 mA CC-E IDC/I 1) 1SVR011785R1100 4-20 mA CC-E IAC/ILPO 2) 1SVR010203R0500 0.052 (0.115) 1SVR040006R0100 0.128 (0.282) 1SVR040007R0200 0.127 (0.280) 0-5 A, 0-20 A, AC 0-5 A, 0-20 A, AC/DC 110-240 V AC 0-5 A, 0-20 A, AC CC-U/I 12 250 V AC 0-1 A, 0-5 A, AC 24-48 V DC, 100-300 V DC, 110-240 V AC, 24 V AC 5) 6) 7) 8) 12.10 1SXU000023C0202 Rev. A Catalog number Weight (1 pce) kg (lb) Input signal 0.092 (0.203) 0.095 (0.209) CC-U/I 3) refer to table refer to table CC-U/V 4) 1SVR040008R1300 1SVR040009R1400 0.128 (0.282) with relay output for sinusoidal currents for current RMS values for voltage RMS values Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Analog signal converters Accessories Approximate dimensions al co nv er te rs Pkg qty Weight (1 pce) g (oz) 1SVR430029R0100 1 18.4 (0.65) MAR.01 1SVR366017R0100 10 0.19 (0.007) COV.01 1SVR430005R0100 1 5.2 (0.18) For type Width in mm Type CC-U 22.5 ADP.01 CC-U CC-U 22.5 Catalog number 22,5 .886" ADP.01 7 .275" 3,5 .138" 68,5 2.70 " 3A11 20 .787" MAR.01 2CDC 252 186 F0005 60 2.36" 8 .315" 2CDC 252 187 F0005 62,5 2.46" 10 .394" 22,5 .886" 4,5 .177" 11,5 .453" Approximate dimensions 2CDC 252 185 F0005 Accessories front-to-back size 107 Sealable cover - COV.01 12 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12.11 1SXU000023C0202 Rev. A rs te er Analog signal converters Technical data nv o lc na g Si CC-E/STD, CC-E x/x (universal devices) DIP switch settings Input 0...5 V 0...10 V 0...20 mA 4...20 mA Wiring instruction Switch 1 2 3 4 5 6 7 8 Output 0...5 V 0...10 V 0...20 mA 4...20 mA 0...5 V 0...10 V 0...20 mA 4...20 mA 0...5 V 0...10 V 0...20 mA 4...20 mA 0...5 V 0...10 V 0...20 mA 4...20 mA Burden R M 1.0 kq Burden R m 500 q Legend ON OFF supply CC-U/STD DIP switch settings Switch 1 1 2 3 4 5 6 7 8 Input 12 Adjustment range Potentiometer 0...50 mV 0...100 mV 0...250 mV 0...500 mV 0...1 V 0...2.5 V 0...5 V 0...10 V 1...5 V 2... 10 V -10...+10 V 0...125 mV 0...8 V -22.5...+22.5 mV -11...+11 V 2.5...7.5 V 3.33...9.99 V 10...0 V 100...0 mV 0...1 mA 0...20 mA 4...20 mA 10...50 mA 20...4 mA 20...0 mA -0.45...+0.45 mA -55...+55 mA High fail safe *) Low faile safe *) No fail safe *) Gain 0 A...D 4...5 0...1 7...9 3...4 0 5...7 2 7...9 2...4 0 3...4 3...4 B...F 0 5...7 3...4 2 4...5 A...D 2...4 4...5 0...1 4...5 4...2 B...F 4...6 - Coarse Type 0 C 5 1 8 3 0 6 2 8 3 0 3 3 D 0 6 4 2 5 B 3 4 1 4 3 D 5 - *) Detection of input voltage signal interruptions: If the input signal circuit is interrupted, the output signal changes to the adjusted minimum value (low fail safe) or maximum value (high fail safe). If "No fail safe" is configured, input signal interruptions are not detected. Wiring instruction + 2.5 V Output 0...5 V 0...10 V 1...5 V 2...10 V -10...+10 V -5...+5 V -10...0 V -5...0 V 0...6.66 V -10...+3.33 V -5...+1.66 V 0...8 V 0...4 V -10...-2 V -5...-1 V 1.25...6.25 V -7.5...+2.5 V -3.75...+1.25 V 1.66...8.33 V -6.66...+6.66 V -3.33...+3.33 V -8...0 V -4...0 V 0...1 mA 0...20 mA 4...20 mA 0...10 mA 0...0.5 mA 0...13.33 mA 0...666 A 0...16 mA 0...800 A 0...8 mA 0...400 A 2.5...12.5 mA 125...625 A 3.33...16.66 mA 166...833 A 0.2...1 mA 2...10 mA 100...500 A Switch 2 1 2 3 4 5 6 OUT [%] 100 90 80 70 Gain "gain-coarse" und "gain-fine" 60 50 40 30 20 1 10 IN [%] 10 20 30 40 50 60 70 80 90 100 Offset remote poti SW1.6 = +22.5 % SW1.4 = +100 % SW1.5 = +50 % Legend ON OFF no influence G Pot. J Burden R M 4.7 kq H Burden R m 600 q supply 12.12 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Analog signal converters Technical data al co nv er te rs CC-U/STDR with relay output Wiring instruction DIP switch settings Value R1 Switch 1 2 3 4 5 6 Input Threshold Hysteresis Value R2 0...0 V 0...5 V 0...1 V -10...+10 V 1...5 V 0...20 mA 4...20 mA Legend ON OFF no influence Output Closed-circuit principle Open-circuit principle supply Function diagrams Switching points Closed-circuit principle Switching points of the output relay depending on the input range, configuration open-circuit principle R1 Threshold value R1 Hysteresis IN [%] Temperature 100 R2 Threshold value lu e R2 Hysteresis 11-14 R1 11-12 21-24 R2 21-22 Ac tu al va 90 Threshold value R1 2-100 % of input range 80 Hysteresis R1 5-50 % of threshold value R1 70 60 Open-circuit principle 50 R1 Threshold value R1 Hysteresis 40 Threshold value R2 2-100 % of input range Temperature R2 Hysteresis 30 20 R2 Threshold value Hysteresis R2 5-50 % of threshold value R2 10 0 11-14 R1 11-12 21-24 R2 21-22 R1 11-14 11-12 R2 21-24 21-22 12 OUT CC-E/RTD DIP switch settings Input 0...100 C 0...300 C 0...500 C -50...+50 C -50...+250 C -50...+450 C Output Wiring instruction Switch 1 2 3 4 5 6 0...10 V 0-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA 0-10 V 0-20 mA 4-20 mA G Burden R M 1.0 kq H Burden R m 500 q J supply Legend ON OFF no influence High fail safe Low fail safe CC-E IAC/ILPO Wiring instruction Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12.13 1SXU000023C0202 Rev. A rs te er Analog signal converters Technical data nv na g Si o lc CC-U/RTD DIP switch settings Wiring instruction Input Switch 1 Switch 2 Type Range 1 2 3 4 5 6 1 2 3 4 5 6 0...500 C 0...550 C 0...600 C 0...650 C PT10 0...700 C 0...750 C 0...800 C 0...850 C 0...50 C 0...60 C 0...70 C 0...80 C 0...90 C PT100 0...100 C 0...200 C 0...300 C 0...400 C 0...500 C 0...10 C 0...20 C 0...30 C PT1000 0...40 C 0...50 C 0...60 C Low fail safe *) High fail safe *) *) Detection of input signal interruptions: G If the input signal circuit is interrupted, the output signal changes to the adjusted minimum value (low fail safe) or maximum value (high fail safe). Burden R M 4.7 kq J Burden R m 600 q H supply Characteristic curves Resistance of PT10, PT100 and PT1000 sensors depending on the temperature PT1000 Switch 3 1 2 3 4 5 6 0...5 V 0...10 V 1...5 V 2...10 V -10...+10 V -5...+5 V -10...0 V -5...0 V 0...6.66 V -10...+3.33 V -5...+1.66 V 0...8 V 0...4 V -10...-2 V -5...-1 V 1.25...6.25 V -7.5...+2.5 V -3.75...+1.25 V 1.66...8.33 V -6.66...+6.66 V -3.33...+3.33 V -8...0 V -4...0 V 0...1 mA 0...20 mA 4...20 mA 0...10 mA 0...0.5 mA 0...13.33 mA 0...666 A 0...16 mA 0...800 A 0...8 mA 0...400 A 2.5...12.5 mA 125...625 A 3.33...16.66 mA 166...833 A 0.2...1 mA 2...10 mA 100...500 A Legend ON OFF no influence Resistance [q] Output 12 Gain Coarse F E D C B A 9 8 F E B A 9 8 3 2 1 0 8 3 2 1 0 0 - PT100 PT10 Temperature [C] CC-E I/I-1 and CC-E I/I-2 Wiring instruction CC-E I/I-1 CC-E I/I-2 Channel 1 Channel 1 input 0-20 mA or 4-20 mA output 0-20 mA or 4-20 mA IN OUT C F Channel 1 input 0-20 mA or 4-20 mA Channel 1 IN C F D E OUT output 0-20 mA or 4-20 mA UL UL IN D E IN OUT OUT 100 q m RL m 500 q 100 q m RL m 500 q Channel 2 input 0-20 mA or 4-20 mA Chanel 2 IN A H B G OUT output 0-20 mA or 4-20 mA UL IN OUT 100 q m RL m 500 q 12.14 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Analog signal converters Technical data al co nv er te rs CC-U/RTDR with relay output DIP switch settings Wiring instruction Value R1 Switch 1 2 3 4 5 6 Input PT100 G 0...100 C 0...200 C 0...400 C 0...600 C 0...800 C u Legend ON OFF no influence J Threshold E (12) F (11) D (14) R2 B (22) C (21) A (24) Hysteresis H Output R1 Value R2 Closed-circuit principle Open-circuit principle K M supply Switching points Function diagrams Switching points of the output relay depending on the input range, configuration open-circuit principle IN [%] Closed-circuit principle R1 Threshold value R1 Hysteresis 100 Temperature al 90 R2 Hysteresis Threshold value R1 2-100 % of input range 600 500 Ac tu 700 Temperature u [C] va lu e 800 80 R2 Threshold value Hysteresis R1 5-50 % of threshold value R1 70 60 11-14 R1 11-12 21-24 R2 21-22 50 400 300 Threshold value R2 2-100 % of input range 200 30 20 100 Open-circuit principle 40 R1 Threshold value Hysteresis R2 5-50 % of threshold value R2 R1 Hysteresis Temperature 10 R2 Hysteresis R2 Threshold value 0 50 100 150 200 250 300 350 OUT 400 Resistance [q] R1 11-14 11-12 R2 21-24 21-22 12 11-14 R1 11-12 21-24 R2 21-22 CC-E/TC, CC-E/I DIP switch settings CC-E/I DIP switch settings CC-E/TC Input TC-J: 0...600 C TC-K: 0...1000 C Output Switch 1 2 3 4 5 6 0...10 V 0...20 mA 4...20 mA 0...10 V 0...20 mA 4...20 mA High fail safe Low fail safe Input Output I - DC I - AC I - DC I - AC I - DC I - AC 0...20 mA Switch 1 2 3 4 5 6 0...10 V 4...20 mA Legend ON OFF Legend ON OFF no influence Wiring instruction CC-E/TC and CC-E/I Input range selection - CC-E/I Select input range by terminals Burden R M 1.0 kq Burden R m 500 q Input range 5 A Connected lines Used terminals Terminal marking Input range 20 A supply Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Connected lines Used terminals Terminal marking 12.15 1SXU000023C0202 Rev. A rs te er nv na g Si o lc Analog signal converters Technical data CC-U/V DIP switch settings Output Switch 1 2 3 4 5 6 0...5 V 0...10 V 1...5 V 2...10 V -10...+10 V -5...+5 V -10...0 V -5...0 V 0...6.66 V -10...+3.33 V -5...+1.66 V 0...8 V 0...4 V -10...-2 V -5...-1 V 1.25...6.25 V -7.5...+2.5 V -3.75...+1.25 V 1.66...8.33 V -6.66...+6.66 V -3.33...+3.33 V -8...0 V -4...0 V 0...1 mA 0...20 mA 4...20 mA 0...10 mA 0...0.5 mA 0...13.33 mA 0...666 A 0...16 mA 0...800 A 0...8 mA 0...400 A 2.5...12.5 mA 125...625 A 3.33...16.66 mA 166...833 A 0.2...1 mA 2...10 mA 100...500 A Wiring instruction Selecting input range by front-face rotary switch 0...100 V 0...150 V 0...250 V 0...300 V 0...400 V 0...450 V 0...550 V 0...600 V Switch position 1 2 3 4 5 6 7 8 Burden R M 4.7 kq Burden R m 600 q supply Example of application RMS measurement and conversion of a phase-angle controlled voltage signal L1 = 230 V INUeff [V] U(t) [V] resulting RMS value 300 Gain w15 % OUT [%] 0 Legend ON OFF no influence 12 Input range selection 0 50 100 Offset w20 % -300 operating angle CC-U/I DIP switch settings Output Switch 1 2 3 4 5 6 0...5 V 0...10 V 1...5 V 2...10 V -10...+10 V -5...+5 V -10...0 V -5...0 V 0...6.66 V -10...+3.33 V -5...+1.66 V 0...8 V 0...4 V -10...-2 V -5...-1 V 1.25...6.25 V -7.5...+2.5 V -3.75...+1.25 V 1.66...8.33 V -6.66...+6.66 V -3.33...+3.33 V -8...0 V -4...0 V 0...1 mA 0...20 mA 4...20 mA 0...10 mA 0...0.5 mA 0...13.33 mA 0...666 A 0...16 mA 0...800 A 0...8 mA 0...400 A 2.5...12.5 mA 125...625 A 3.33...16.66 mA 166...833 A 0.2...1 mA 2...10 mA 100...500 A Input range selection Wiring instruction Select input range by terminals Burden R M 4.7 kq Input range 1 A Connected lines Used terminals Terminal marking J H 1A 5A G Burden R m 600 q C Input range 5 A Connected lines Used terminals Terminal marking J 5A H 1A G supply C Example of application RMS measurement and conversion of a current signal IN [%] Gain w15 % I(t) [A] 5 4 3 2 1 resulting RMS value 0 -1 Legend ON OFF no influence 12.16 1SXU000023C0202 Rev. A t 0 50 100 OUT [%] -2 -3 Offset w20 % -4 -5 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Analog signal converters Technical data al co nv er te rs CC-U/TC Wiring instruction DIP switch settings Input Switch 1 Switch 2 Range 1 2 3 4 5 6 1 2 3 4 5 6 0-100...900 C K 0-250...1350 C 0-100...750 C J 0-100...400 C T -150-0...400 C S 0-250...1550 C 0-100...700 C E 0-200...1000 C 0-100...650 C N 0-200...1300 C 0-250...1350 C R 0-450...1700 C B 0-700...1750 C 0-2...10 mV mV 0-10...50 mV Low fail safe *) High fail safe *) Switch 3 1 2 3 4 5 6 Output Type 0...5 V 0...10 V 1...5 V 2...10 V -10...+10 V -5...+5 V -10...0 V -5...0 V 0...6.66 V -10...+3.33 V -5...+1.66 V 0...8 V 0...4 V -10...-2 V -5...-1 V 1.25...6.25 V -7.5...+2.5 V -3.75...+1.25 V 1.66...8.33 V -6.66...+6.66 V -3.33...+3.33 V -8...0 V -4...0 V 0...1 mA 0...20 mA 4...20 mA 0...10 mA 0...0.5 mA 0...13.33 mA 0...666 A 0...16 mA 0...800 A 0...8 mA 0...400 A 2.5...12.5 mA 125...625 A 3.33...16.66 mA 166...833 A 0.2...1 mA 2...10 mA 100...500 A Burden R M 4.7 kq Burden R m 600 q supply 1) *) Detection of input signal interruptions: If the input signal circuit is interrupted, the output signal changes to the adjusted minimum value (low fail safe) or maximum value (high fail safe). without cold-junction compensation: switch SW2.2 = OFF Legend ON OFF no influence 12 Characteristic curve Thermocouple voltages depending on the temperature 80000 Typ E 75000 Typ J 70000 65000 60000 Typ K 55000 50000 Typ N Thermoelement-Spannung [V] 45000 40000 35000 30000 25000 Typ R Typ T 20000 Typ S 15000 10000 Typ B 5000 0 -5000 -10000 1800 1750 1700 1650 1600 1550 1500 1450 1400 1350 1300 1250 1200 1150 1100 950 1050 1000 900 850 800 750 700 650 600 550 500 450 400 350 300 250 200 150 0 50 100 -50 -100 -150 -200 -250 -15000 Temperatur [C] Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12.17 1SXU000023C0202 Rev. A rs te er Analog signal converters Technical data nv o lc na g Si CC-U/TCR with relay output DIP switch settings Function diagrams Wiring instruction Closed-circuit principle Type J K T S R1 Threshold value Input Switch Range 1 2 3 4 5 6 0...240 C 0...480 C 0...1200 C 0...250 C 0...500 C 0...1350 C -150...+120 C 0...220 C 0...400 C 0...210 C 0...380 C 0...860 C 0...1550 C Value R1 R1 Hysteresis Temperature R2 Hysteresis R2 Threshold value Threshold Hysteresis 11-14 R1 11-12 21-24 R2 21-22 Value R2 Open-circuit principle R1 Threshold value R1 Hysteresis supply Temperature Output R2 Hysteresis Closed-circuit principle Open-circuit principle R2 Threshold value Legend ON OFF no influence 11-14 R1 11-12 21-24 R2 21-22 Switching points Switching points of the output relay depending on the input range, configuration open-circuit principle IN [%] 12 100 7000 Threshold value R1 = 1000 C Typ J 6500 6000 Thermocouple voltage [V] 5500 5000 Typ K Release hysteresis 4500 4000 3500 Threshold value R2 = 400 C 3000 2500 Typ T Release hysteresis 2000 1500 Typ S 1000 500 0 0 OUT -500 -1000 12.18 1SXU000023C0202 Rev. A R1 R2 21-24 21-22 1825 1725 1625 1525 1425 1325 1225 1125 925 Temperature [C] 1025 825 725 625 525 425 325 25 225 125 -75 -175 -275 -1500 11-14 11-12 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Analog signal converters Technical data Type CC-E/RTD 3) CC-E/STD Input circuits - Analog inputs J-G-H Input signal Rated input range Current Voltage Limitation of input signals Influence of line resistance Gain adjustment range Offset adjustment range Input impedance Suppression at 50 Hz Common-mode rejection 50 Output signal Output burden Accuracy 1) Residual ripple Response time Transmission frequency Reaction to input circuit interruption 200 s 2 kHz er te rs TC.K: 0...1000 C, TC.J: 0...600 C -50...+500 C < 0.01 %/ 5 % (universal devices) 5 % (universal devices) < 0.5 % / 100 - > 35 dB 1 M D-F, A-C nv CC-E/TC PT100 - Output circuits - Analog outputs co Thermocouples (IEC 584-1 and 2) TC.K, TC.J Temperature sensors Standard signals 0...5 V / 0...20 mA / 0...10 V / 4...20 mA -10...+10 V +55 mA 11 V - al 100 dB Current Voltage 0-20 mA, 4-20 mA 0-5 V, 0-10 V 500 1.0 K 0.5 % of full-scale < 0.5 % 10 ms 80 Hz 2 Hz (up to -3 dB) High fail safe: Output voltage > 115 % of measuring range 2) Low fail safe: Output voltage < -0.6 V, output current = 0 mA Supply circuits K-M Supply voltage Supply voltage tolerance Power consumption DC versions AC versions 24 V DC -15...+15 % 1.5 W typ. 110-240 V AC - 50/60 Hz -15...+10 % 1.5 VA typ. Indication of operational states Rated control supply voltage US U: green LED General data Ambient temperature range Temperature coefficient Degree of protection (DIN 40050) Mounting position Mounting operation / storage 0...+60 C / -20...+80 C 500 ppm/C IP20 ventilation slots on top and bottom DIN rail (IEC/EN 60715), snap-on mounting Electrical connection Wire size 0.2-4 mm2 (24-12 AWG) 0.2-2.5 mm2 (24-14 AWG) 7 mm (0.28 inch) 0.5 Nm (4.4 lb.in) rigid fine-strand with(out) wire end ferrule Stripping length Tightening torque Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) electromagnetic field (HF radiation resistance) fast transients (Burst) powerful impulses (Surge) HF line emission Interference emission EN 61000-6-2 Level 3 (6 kV / 8 kV) IEC/EN 61000-4-2 IEC/EN 61000-4-3 10 V/m IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 EN 61000-6-4 Level 3 (2 kV / 5 kH) 2 kV / 1 kV 10 V Class B Isolation data Test voltage between all isolated circuits Rated insulation voltage 1) Includes non-linearity and factory setting, influenced by supply voltage and output load. 2) Only -/RTD and -/TC: Single-function devices respond with Low fail safe to input signal interruptions. 3) When connecting a 2-wire sensor, the terminals J and H have to be jumpered. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage - 2.5 kV AC - - 12.19 1SXU000023C0202 Rev. A 12 rs te er nv na g Si o lc Analog signal converters Technical data Type Input circuits - Analog inputs CC-E I/I Current Input current IIN 0-20 mA, 4-20 mA Min. input current < 100 A Max. input current 50 mA1) (VIN < 18 V) Input voltage UIN < 2.5 V + (IIN x RL) Input voltage drop Ui < 2.5 V (20 mA, RL = 0 ) 18 V1) (IIN < 50 mA) Max. input voltage Output circuits Output current IOUT 0-20 mA, 4-20 mA Output load RL 0-500 Output voltage UOUT IOUT x RL Residual ripple < 20 mVpp (500 , 20 mA) Response time (0-100 %) < 15 ms (0-500 , 20 mA), < 5 ms (500 , 20 mA, 25 C) Accuracy 0.1 % of full-scale (20 mA) Load influence (0-500 ) 0.05 % / 100 , -0.1 % / 100 (25 C) General data Width of the enclosure 18 mm Weight 1 channel approx. 0.037 kg (0.082 (0.181) lb) 2 channel approx. 0.044 (0.097) kg (0.097 lb) Mounting position any Degree of protection enclosure / terminals Ambient temperature range 12 operation / storage Temperature coefficient IP20 / IP20 -25...+60 C / -40...+85 C < 50 ppm / C Mounting DIN rail (IEC/EN 60715) Electrical connection Wire size 0.2-4 mm2 (24-12 AWG) rigid fine-strand with(out) wire end ferrule 0.2-2.5 mm2 (24-14 AWG) Stripping length 7 mm (0,28 inch) Tightening torque 0.5 Nm (4.4 lb.in) Standards Product standard EN 50178 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) EN 61000-6-2 EN 61000-4-2 Level 3 (6 kV / 8 kV) electromagnetic field (HF radiation resistance) EN 61000-4-3 10 V/m fast transients (Burst) EN 61000-4-4 Level 3 (2 kV / 5 kH) powerful impulses (Surge) EN 61000-4-5 2 kV / 1 kV HF line emission EN 61000-4-6 10 V magnetisches Feld EN 61000-4-8 30 A/m Interference emission Radiated noise EN 61000-6-4 EN 55011 Class B Operational reliability (EN 68-2-6) 4g Mechanical resistance (EN 68-2-6) 10 g Environmental testing (IEC 68-2-30 Db) 24 h cycle, 55 C, 93 % rel., 96 h Isolation data Insulation voltage input / output Insulation voltage between channels 500 Veff / 50 Hz 5 kVeff / 50 Hz (device with 2 channels) Pollution category 2 Overvoltage category II 1) The input parameters have to be limited to the indicated maximum values. 12.20 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Analog signal converters Technical data Type Input circuits - Analog inputs CC-U/STD J-G-H Input signal PoCurrent Voltage tentiometer 0-20 mA 0-100 470 mV 4-20 mA 1 M 2) al co nv er te CC-U/RTD 3) CC-U/TC Temperature sensors Thermocouples (IEC 584-1 and 2) PT10, PT100, PT1000 TC.K TC.J (IEL 751 and JICC 1604) TC.T TC.S 10-50 mA 0-1 V TC.E TC.N 0-5 V TC.R TC.B 0-1 mA 1-5 V rs 0-10 V 2-10 V 10 V 55 mA 11 V Limitation of input signals Rated input range - - Max. temperature adjustable: - 6-60 C for PT1000 50-500 C for PT100 Influence of line resistance Gain adjustment range (universal devices) 0.9- 45 mV - - 500-850 C for PT10 0.015 C/ refer to temperature specs. of individual thermocouples < 0.01 % / 100 see DIP switch settings 110 mA 22 V -137.5...+62.5 % 5% 10 % for different ranges 51 6 M 3 G 51 3.5 M 9.5 G > 40 dB 120 dB 105 dB D-F, A-C Current Voltage 0-20 mA, 4-20 mA 0-5 V, 1-5 V, 0-10 V, 2-10 V, 10 V 600 4.7 K 0.1 % of full-scale 0.2 % of full-scale 0.1 % of full-scale < 0.15 % 200 s 10 ms 200 ms 1 kHz 80 Hz 2 Hz (to -3 dB) K-M Offset adjustment range (universal devices) Input impedance without detection of inp ut signal interruption with detection of input signal interruption Suppression at 50 Hz Common-mode rejection Output circuits - Analog outputs Output signal Output burden Accuracy 1) Residual ripple Response time Transmission frequency Supply circuits Rated supply voltage Supply voltage range Supply voltage tolerance Rated frequency Power consumption 24-48 V DC 110-240 V AC 24-48 V DC / 24 V AC 110-240 V AC / 100-300 V DC DC: -15...+15 % AC: -15...+10 % 0 Hz or 50/60 Hz 2 W at 24 V DC 4.5 VA at 230 V AC Indication of operational states Supply voltage U: green LED General data Ambient temperature range Temperature coefficient operation / storage -20...+60 C / -40...+80 C 150 ppm/C Mounting position Mounting 250 ppm/C 200 ppm/C at min. offset 400 ppm/C at max. offset any DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter Electrical connection Wire size rigid fine-strand with(out) wire end ferrule Stripping length Tightening torque plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG) plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG) 7 mm (0.28 inch) 0.4 Nm (3.5 ib.in) Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) electromagnetic field (HF radiation resistance) fast transients (Burst) powerful impulses (Surge) HF line emission Interference emission IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 EN 61000-6-4 EN 61000-6-2 Level 3 (6 kV / 8 kV) 10 V/m Level 3 (2 kV / 5 kH) 2 kV / 1 kV 10 V Class B Isolation data Isolation test (between all isolated circuits) 1.5 kV Test voltage (between all isolated circuits) 1.5 kV / 50 Hz 1) Includes non-linearity and factory setting, influenced by supply voltage and output load. 2) Detection of an input signal break (fail safe) and resistance > 10 kq results in a linearity of w0,2 %. 3) When connecting a 2-wire sensor, the terminals J and H have to be jumpered. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12.21 1SXU000023C0202 Rev. A 12 rs te er Analog signal converters Technical data nv na g Si o lc Type Input circuits - Analog inputs CC-U/STDR J-H Measuring signal / input range CC-U/RTDR 1) CC-U/TCR Current Voltage Temperature sensors Thermocouples (IEC 584-1 and 2) 0-20 mA 0-1 V / 1-5 V PT100 TC.K, TC.J 4-20 mA TC.T, TC.S 0-10 / 10 V Input resistance approx. 50 approx. 1,5 M Adjustable threshold 2-100 % of selected input range Adjustable hysteresis 5-50 % of threshold Repeat accuracy (constant parameters) 0.5 % of full-scale Output circuits - Relay outputs E-D-F, B-C-A Relay, 2 c/o contacts Rated switching voltage Rated switching c urrent 250 V AC AC12 (resistive) 230 V 4A AC15 (inductive) 230 V 3A DC12 (resistive) 24 V 4A DC13 (inductive) 24 V AC rating (UL 508) 2A Utilization category (Control Circuit Rating Code) B 300 max. rated operational voltage 300 V AC max. continuous thermal current at B 300 5A max. making/breaking apparent power at B 300 3600/360 VA Minimum switching voltage 12 V Minimum switching current / power 10 mA / 0.6 VA (W) Response time Mechanical lifetime Electrical lifetime 12 10 ms 30 x 106 switching cycles 0.1 Mio. switching cycles at AC12, 230 V, 4 A Supply circuits K-M Rated supply voltage 24-48 V DC Supply voltage range 24-48 V DC / 24 V AC Supply voltage tolerance 110-240 V AC 110-240 V AC / 100-300 V DC DC: -15...+15 % Rated frequency AC: -15...+10 % 0 Hz or 50/60 Hz Power consumption 2 W at 24 V DC 4.5 VA at 230 V AC Indication of operational states Supply voltage U: green LED 1st / 2nd output relay energized R1: yellow LED / R2: yellow LED General data Ambient temperature range operation / storage -20...+60 C / -40...+80 C Temperature coefficient 300 ppm/C Mounting position any Mounting DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter Electrical connection Wire size rigid plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG) fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG) Stripping length 7 mm (0.28 inch) Tightening torque 0.4 Nm (3.5 ib.in) Electromagnetic compatibility Interference immunity EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 10 V/m fast transients (Burst) IEC/EN 61000-4-4 Level 3 (2 kV / 5 kH) powerful impulses (Surge) IEC/EN 61000-4-5 2 kV / 1 kV HF line emission IEC/EN 61000-4-6 Interference emission EN 61000-6-4 Level 3 (6 kV / 8 kV) 10 V Class B Isolation data Insulation voltage (between all isolated circuits) 2.5 kV Test voltage (between all isolated circuits) 2.5 kV 1) When connecting a 2-wire sensor, the terminals J and H have to be jumpered. 12.22 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Analog signal converters Technical data Type CC-E/I Rated input range co nv er te rs CC-E IAC/ILPO J-G-H Input circuits - Analog inputs al C-D AC current DC current 2 meas. ranges selectable 0-5 A / 0-20 A 0-5 A / 0-20 A 0-1 A / 0-5 A / sinusoidal Measuring frequency 50/60 Hz Overload capacity of inputs input range 1 10 x INom (50 A) for max. 1 s 10 x INom (50 A) for max. 2 s input range 2 10 x INom (200 A) for max. 1 s 10 x INom (200 A) for max. 2 s Gain adjustment range 5 % (universal devices) - Offset adjustment range 5 % (universal devices) - Input impedance / resistance Output circuits - Analog outputs Output signal 5A : 65 m 20 A : 2.5 m 5 m D-F Current A-C Voltage F-E passive current output in proportion to input current 0-20 mA / 4-20 mA 0-10 V 4-20 mA 1.0 12 V DC: 150 , 24 V DC: 750 Output burden / load 500 30 V DC: 1050 Accuracy 1) 2 % of full-scale Offset adjustment range 5 % (universal device) 5% Gain adjustment range 5 % (universal device) 20 % Residual ripple < 0.5 % Response time Transmission frequency Reaction to input circuit interruption Supply circuits K-M Supply voltage Supply voltage tolerance Power consumption 0.5 s 0.6 s DC or 50/60 Hz AC: 50/60 Hz Low fail safe: output voltage < 200 mA, output current < 400 A - DC versions AC versions 24 V DC 110-240 V AC 50/60 Hz 12-30 V DC -15...+15 % -15...+10 % - typ 1.5 W typ 1.5 VA - 12 Indication of operational states Supply voltage U: green LED - 0...+60 C / -20...+80 C -20...+60 C / -40...+80 C General data Ambient temperature range operation / storage Temperature coefficient 500 ppm/C Degree of protection (DIN 40050) 300 ppm/C IP20 Mounting position ventilation slots on top and bottom Mounting DIN rail (IEC/EN 60715), snap-on mounting Electrical connection Wire size rigid 0.2-4 mm (24-12 AWG) fine-strand with(out) wire end ferrule 0.2-2.5 mm (24-14 AWG) Stripping length 7 mm (0.28 inch) Tightening torque 0.5 Nm (4.4 lb.in) Electromagnetic compatibility Interference immunity electrostatic discharge (ESD) EN 61000-6-2 IEC/EN 61000-4-2 Level 3 (6 kV / 8 kV) electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 10 V/m fast transients (Burst) IEC/EN 61000-4-4 Level 3 (2 kV / 5 kH) 2 kV / 1 kV powerful impulses (Surge) IEC/EN 61000-4-5 HF line emission IEC/EN 61000-4-6 Interference emission EN 61000-6-4 10 V Class B Isolation data Test voltage (between all isolated circuits) Rated insulation voltage 1) 2.5 kV AC - 250 V AC Includes non-linearity and factory setting, influenced by supply voltage and output load. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12.23 1SXU000023C0202 Rev. A rs te er Analog signal converters Technical data nv na g Si o lc Type Input circuits - Analog inputs J-G-H Rated input range CC-U/I CC-U/V any current signals, RMS measurement any voltage signals, RMS measurement 0-100 V, 0-200 V 0-1 A 0-300 V, 0-400 V 0-5 A 0-500 V, 0-600 V Measuring frequency 0-600 Hz Overload capacity of inputs input range 1 10 x INom (10 A) for max. 2 s input range 2 10 x INom (50 A) for max. 2 s Gain adjustment range 15 % Offset adjustment range 20 % Input impedance / resistance 1A: 60 m, 5 A: 12 m Output circuits - Analog outputs D-F, A-C Output signal Output load > 800 k Current Voltage 0-20 mA, 4-20 mA 0-5 V, 1-5 V, 0-10 V, 2-10 V, 10 V 600 4.7 K Accuracy1) 0.5 % of full-scale Temperature coefficient 250 ppm/C max. 300 ppm/C max. Residual ripple < 0.15 % Response time 150 ms Supply circuits K-M Rated supply voltage 24-48 V DC 110-240 V AC Supply voltage range 24-48 V DC, 24 V AC 110-240 V AC, 100-300 V DC Supply voltage tolerance DC: -15...+15 % Rated frequency AC: -15...+10 % 0 Hz or 50/60 Hz Power consumption 12 - 2 W at 24 V DC 4.5 VA at 230 V AC Indication of operational states Supply voltage U: green LED General data Ambient temperature range operation / storage -20...+60 C / -40...+80 C Mounting position any Mounting DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter Electrical connection Wire size rigid plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG) fine-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG) Stripping length 7 mm (0.28 inch) Tightening torque 0.4 Nm (3.5 lb.in) Standards Product standard - Low Voltage directive 2006/95/EG EMC directive 2004/108/EG RoHS directive 2002/95/EG Electromagnetic compatibility Interference immunity EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 10 V/m fast transients (Burst) IEC/EN 61000-4-4 Level 3 (2 kV / 5 kH) powerful impulses (Surge) IEC/EN 61000-4-5 2 kV / 1 kV HF line emission IEC/EN 61000-4-6 Interference emission EN 61000-6-4 Level 3 (6 kV / 8 kV) 10 V Class B Isolation data Insulation voltage (between all isolated circuits) Test voltage (between all isolated circuits) 1) 1.5 kV 1.5 kV / 50 Hz Includes non-linearity and factory setting, influenced by supply voltage and output load. 12.24 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Analog signal converters Technical diagrams, connection diagrams Approximate dimensions Technical diagrams Connection diagram CC-U/x Load limit curves CC-U/xxR Width 22.5 mm (0.89 in) Resistive AC load al co nv er te rs Resistive DC load M L K J H G D E F A B C Derating curve 1.0 0.9 0.8 F 0.7 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 12 1.0 cos Dimensional drawings CC-U/x , CC-U/xR CC-E/x Dimensions in mm and inches CC-E IAC/ILPO, CC-E I/I .039 22.5 0,88 " Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 18 0.71" 12.25 1SXU000023C0202 Rev. A rs te er nv Notes na g Si o lc 12 12.26 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Serial data converters Si gn al co nv er te rs Ethernet communication is now one of the main features need in open communication, ABB propose the e-ILPH to connect the serial devices to the web world. Serial data Converters In the field of industrial data transmission, various processes of data transmission and interfaces are used today. Already existing systems need to be updated or connected to new devices for continuity of process. When new communication functions are not build-in, ABB propose a range of converters to be able to use from the standard RS232 or RS485, to the Ethernet open products or the Optical Fiber. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12.27 1SXU000023C0202 Rev. A 12 rs te er Serial data converters Overview nv a gn Si o lc Uses Example : Adaptation The use of converters allows the connection of two devices using different interfaces. To add new equipment to existing installations. RS-232 RS-485 Example : Galvanic Isolation Line 1 To protect sensitive equipment it is sometimes necessary to use converters which allow galvanic isolation. Line 2 To cross a disturbed environment Power Some interfaces are more sensitive to noise. Electrically, it is preferable, in some cases, to change the interface or support. Type of connection Immunity to noise RS232 Low RS422 High RS485 High CL High OF Ethernet Very high High Multipoint connections 12 Noisy elements Example : RS-232 RS-422 Example : Some equipment is only designed to communicate in RS232 point to point connection. To communicate with several devices it is then necessary to use converters RS232 to RS422, RS485, CL or OF to reach multipoint mode. Type of connection Connection RS232 Point to point RS422 12 points RS485 32 points CL 5-6 points OF Ethernet 32 points Point to point or multipoint Increase in the transmission and amplification distances of the signals RS-485 2-/4 wires RS-232 RS-232 Example : Every connection has its own limits, to increase the communication distances you only have to change the type of link (converter) or amplify the signal (Repeater) using an ILPH. Type of connection RS-232 RS-422 Converter RS-232 RS-232 RS-232 Repeater RS-422 RS-422 15 m 1.2 km 1.2 km 15 m max. max. max. max. Max. distances * RS232 15m RS422 1.2km RS485 1.2km CL 300-500m OF Ethernet 4km 100 m with CAT5 cable RS-232 RS-232 * Depending on transmission speed. "World Wide" communication Example : Communication is more and more used with Ethernet support. The interests are to have a distant access, to use an already existing network and to upload information and data on a supervisor or a computer. The conversions from serial to Ethernet protocol are used to connect local network to Ethernet. TCP RS-232 RS-485 Example : Protocol conversion Modbus is one of the main protocols used in the industrial networks. The creation of Modbus/TCP allows an adapted access to the Ethernet network. So, the conversion between these 2 protocols is necessary. 12.28 1SXU000023C0202 Rev. A Modbus / TCP Modbus / RTU Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn RS232 RS422 /RS485 RS485 RS232 / RS485 al co nv er te rs nu mb er VAC 24 log Ca ta Ins ula tio n* 10VD C, 34 VA C/ DC 10- -4 2 VA C 24 40 C 0 -2 11 VD 24 -4 8 C VD 24 Eth ern et OF -P OF -S CL 2/ RS 42 RS 23 2 RS 48 5 Serial data converters Selection table In-Ps-Out 1SNA684234R2000 In-Ps-Out 1SNA684244R0200 Wi 1SNA684231R2500 In-Out 1SNA684233R2700 In-Ps-Out 1SNA684333R2300 In-Ps-Out 1SNA684334R2400 In-Out 1SNA684202R0100 In-Ps-Out 1SNA684236R2200 In-Ps-Out 1SNA684237R2300 In-Ps-Out 1SNA684238R0400 In-Ps-Out 1SNA684239R0500 In-Out 1SNA684212R2200 In-Out 1SNA684232R2600 In-Ps-Out 1SNA684246R0400 In-Ps-Out 1SNA684247R0500 In-Ps-Out 1SNA684248R1600 In-Ps-Out 1SNA684249R1700 In-Ps-Out 1SNA684252R0200 12 * In=Input, Ps=Power supply, Out=Output, Wi=Without insulation RS 232 - EIA-232 / V.24 / V.28 RS 485 - ISO/IEC/EIA-485 Point-to-point connection Max. 15 m transmission distance Rate up to 19.2 kbit/s Full-duplex Multi-point connection up to 32 units Differential voltage transmission Half-duplex on 1 pair Full-duplex on 2 pairs Up to 1200 m / 10Mbit/s Good EMC characteristics RS 422 - EIA-422 / V.11 Point-to-point connection (1 Transmitter - 10 Receivers) Differential voltage transmission Full-duplex Up to 1200 m/ 10Mbit/s Good EMC characteristics Current loop(TTY) Point-to-point / multi-point connection Active or passive current loop Full-duplex Up to 1200 m/19.2 kBit/s Good EMC characteristics Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Optical fiber interface Point-to-point connection Full-duplex From 40m up to 4km transmission distance according to optical fiber material (plastic / glass) and wavelength used up to 10 Mbit/s Excellent EMC characteristics Ethernet Interface Point to point connexion or multipoint connection. Up to 100m using CAT5 cable without Hub or Switch 10/100 Mbit/s Good EMC characteristics 12.29 1SXU000023C0202 Rev. A rs te er nv na g Si o lc Serial data converters Benefits and advantages ILPH RS 232 - 485 / Ethernet ILPH RS 232 / RS 422 - 485 Isolated RS232 or/and RS485 to Ethernet converter RS 232 to RS 422-485 serial link without isolation * Triple galvanic isolation * RS232 on SUBD 9 points or screw connectors * RS485 on removable screw connectors * Ethernet 10/100 Mbit/s, RJ45 connector * Power supply 10-34 VDC et 10-24 VAC * Possible to have a redundant 10-34 VDC power supply * Economic with low consumption * Up to 100m with CAT5 cable without Hub or Switch * Good EMC characteristics * Up to 2 Modbus(R)\TCP Masters Available modes: * Modbus(R)\TCP to Modbus(R) RTU conversion * Transparent Client or Server mode * SMTP mode (Mail send) Standards: TPC/IP, TELNET, DHCP, FTP * Specifics functions in Modbus(R) protocol: * Concentrator (Asynchronous mode) up to 1200 words * AC31 programming Modbus(R) Easy Net mode : this mode could be used to exchange data without a Modbus(R)/TCP master. The data are logged in a table and could be distributed to one or all the others e-ILPH participants on Ethernet. ILPH RS 232 / RS 422 - 485 * 3 way galvanic isolated converter for RS 232 to RS 422-485 serial links. galvanic isolation between power supply and input/output 12 ** 3RSway 485 switch on 2 or 4 wires * Baudrate up to 38.4 kbit/s * Transmission distance up to 1200 m * RS 485 1 or 2 pair handling * Usable in "noisy" environments * 24...48 V DC and 115...230 V AC power supply * CE marking ILPH RS 422 - 485 / RS 422 - 485 Galvanic isolated connection between an RS 422-485 (1 or 2 pairs) and an RS 422 485 (1 or 2 pairs) serial link. It amplifies the signal beyond the 1200 m limit distance of the RS 422-485 and only needs a minimum of 1.5 character delay time to switch off the RS 485 drivers. * Galvanic isolation between power supply/output and input/output * Baudrate up to 500 kbit/s (up to 200 m) * Transmission distance up to 1200m at 38.4 kbit/s * Usable in "noisy" environments * 2/4 wires automatic handling * 24 V DC power supply * CE mark * Economic version without isolation * Baudrate up to 38.4 kbit/s * Transmission distance up to 1200 m * RS 485 1 or 2 pair handling * Usable in "noisy" environments * 24 V DC power supply * CE mark ILPH RS 232 / RS 422 - 485 Galvanic isolated converter for RS 232 to RS 422-485 serial links. * Galvanic isolation between input/output and output/power supply * Baudrate up to 38.4 kbit/s * Transmission distance up to 1200 m * RS 485 1 or 2 pair handling * Usable in "noisy" environments * 24 V DC power supply * CE mark ILPH RS 232 / CL Galvanic isolated Converter for RS 232 to current loop serial link. * Galvanic isolation between power supply/current loop and RS 232/current loop * Active/Passive 0...20 mA / 4...20 mA selectable Positive or negative logic selectable * Baudrate up to 38.4 kbit/s * Transmission distance up to 1200 m * Usable in "noisy" environments * 24 V DC power supply * CE marking ILPH RS 232 / RS 232 3 way galvanic isolator between RS 232 serial interface and another RS 232 serial interface. * Ensures triple insulation between the 2 serial interfaces and between each and power supply * Baudrate up to 19.2 kbit/s (up to 64 kbit/s depending on cable) * Transmission distance up to 15 m * Can be used in "noisy" environments * Power supply from 24...48 V DC and 115...230 V AC CE marking ILPH RS 232 / FO ILPH RS 485 / FO * 3 way galvanic isolated Converter for RS 232 to optical fiber serial link glass (S) or plastic (P). * 3 way galvanic isolation between power supply and input/output * Baud rate up to 115.2 kbit/s * Available for glass or plastic fiber * Transmission distance up to 4 km * Usable in "very noisy" environments * 20...42 V AC/DC and 110...240 V AC/DC power supply * CE marked 3 way galvanic isolated converter for RS 485 (1 pair) to optical fiber serial link glass (S) or plastic (P). ILPH CL / RS 422 - 485 * 3 way galvanic isolation between power supply and input/output * Baud rate up to 1.5 Mbit/s * Available for glass fiber or plastic fiber * Transmission distance up to 4 km * Usable in "very noisy" environments * 20...42 V AC/DC and 110...240 V AC/DC power supply * CE marked 12.30 1SXU000023C0202 Rev. A Galvanic isolated converter for current loop to RS 422-485 (1 or 2 pairs) serial link. * Galvanic isolation between power supply/current loop and RS 422-485/current loop * Active/passive 0...20 mA / 4...20 mA selectable Positive or negative logic selectable * Baudrate up to 38.4 kbit/s (up to 2400 m) Transmission distance up to 2400 m (1200 m RS 485 and 1200 m current loop) * Usable in "noisy" environments * 24 V DC power supply * CE marking Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Serial data converters Ordering details Description Type al Catalog number er te rs Weight (1 pce) kg (lb) ILPH RS 232-RS 485 / Ethernet 1SNA684252R0200 0.12 (0.265) Serial link interface without galvanic isolation ILPH RS 232 / RS 422-485 1SNA684231R2500 0.1 (0.220) Serial link interface with galvanic isolation ILPH RS 232 / RS 422-485 1SNA684233R2700 0.1 (0.220) ILPH RS 232 / RS 422-485 (24-48 V DC power supply) 1SNA684333R2300 ILPH RS 232 / RS 422-485 (115-230 V DC power supply) 1SNA684334R2400 ILPH RS 232 / RS 232 (2448 V DC power supply) 1SNA684234R2000 0.1 (0.220) 0.1 (0.220) Serial link interface 3 way galvanic isolation ILPH RS 232 / RS 232 (115230 V DC power supply) 1SNA684234R0200 ILPH RS 422 - 485 / RS 422 - 485 (24 V DC power supply) 1SNA684212R2200 ILPH RS 232 / FO-S (24...42 V AC/DC power supply) 1SNA684236R2200 ILPH RS 232 / FO-S (110...240 V AC/DC power supply) 1SNA684237R2300 ILPH RS 232 / FO-P (24...42 V AC/DC power supply) 1SNA684238R0400 ILPH RS 232 / FO-P (110...240 V AC/DC power supply) 1SNA684239R0500 ILPH RS 485 / FO-S (24...42 V AC/DC power supply) 1SNA684246R0400 ILPH RS 485 / FO-S (110...240 V AC/DC power supply) 1SNA684247R0500 ILPH RS 485 / FO-P (24...42 V AC/DC power supply) 1SNA684248R1600 ILPH RS 485 / FO-P (110...240 V AC/DC power supply) 1SNA684249R1700 Serial link interface with galvanic isoaltion ILPH BdC /RS 422 - 485 (24 V DC power supply) 1SNA684232R2600 0.1 (0.220) Serial link interface with galvanic isolation ILPH RS 232 BdC (24 V DC power supply) 1SNA684202R0100 0.1 (0.220) Serial link interface with galvanic isolation Serial link interface 3 way galvanic isolation Serial link interface 3 way galvanic isolation ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage nv Serial data converter e-ILPH Serial link interface 3 way galvanic isolation Low Voltage Products & Systems co 0.1 (0.220) 0.15 (0.331) 0.15 (0.331) 12.31 1SXU000023C0202 Rev. A 12 rs te er nv o lc a gn Si ILPH RS 232 - 485 Ethernet Serial data converters Jumper Approximate dimensions ILPH RS 232 - 485 Ethernet (without isolation) ILPH RS 232 - 485 Ethernet (isolated) center of rail center of rail center of rail Rt Configuration of the jumper Rt R Configuration of the jumpers E R E ILPH RS 232 / RS 232 12 RS 485 LINK ON ONE PAIR RS 485 LINK ON ONE PAIR R R ON/OFF Jumper R in position R ON/OFF R R ON/OFF Jumper R in position R ON/OFF E E ON/OFF Jumper E in position E ON/OFF E E ON/OFF Jumper E in position E ON/OFF The Receiver and the Transmitter are activated alternately (never at the same time) depending on the status of the CTRL IN signal. center of rail CTRL IN STATUS ACTION ON RS 485 0 logic (+3V U +25V) 1 logic (-25V U -3V) High impedance Transmitter active / Receiver inactive Transmitter inactive /Receiver active Transmitter inactive /Receiver active NOTE : For RS 232 products running the RTS ( REQUEST TO SEND) signal, connect RTS to CTRL IN. Otherwise, connect M (RxD ILPH) to L (CTRL IN). RS 485 LINK ON 2 PAIRS CAUTION : For RS 232 products running the RTS ( REQUEST TO SEND) signal, connect RTS to CTRL IN. Otherwise, connect M (RxD ILPH) to L (CTRL IN). Jumper R in position R ON RS 485 LINK ON 2 PAIRS Jumper E in position E ON/OFF R R ON Jumper R in position R ON Receiver permanently active E E ON/OFF Jumper E in position E ON/OFF Transmitter controlled by the signal CTRL IN (see table for Transmitter operation as a function of CTRL IN) Receiver permanently active Transmitter controlled by the signal CTRL IN ( see table for Transmitter operation as a function of CTRL IN ) RS 422 LINK ON TWO PAIRS R R ON Jumper R in position R ON E E ON Jumper E in position E ON The Transmitter and Receiver are both permanently active. POLARIZATION OF THE RS 422 - RS 485 LINE The line must always be polarized. The ILPH is used to polarize the reception channel : Connection by 1 wire P+ (J1.1) with 5V (J1.4) Connection by 1 wire P- (J1.2) with 0V (J1.3) ADAPTING THE RS 422 - RS 485 LINE The line must always be adapted to the level of t he reception channel of each subscriber forming the end of the bus. The ILPH is used to adapt the reception channel by setting the jumper Rt correctly : RS 422 LINK ON TWO PAIRS R ON Jumper R in position R ON R E E ON Jumper E in position E ON The Transmitter and Receiver are both permanently active. POLARIZATION OF THE RS 422 - RS 485 LINE The line must always be polarized. The ILPH is used to polarize the reception channel : Connection by 1 wire P+ (J1.1) with 5V (J1.4) Connection by 1 wire P- (J1.2) with 0V (J1.3) ADAPTING THE RS 422 - RS 485 LINE The line must always be adapted to the level of the reception channel of each subscriber forming the end of the bus. The ILPH is used to adapt the reception channel by setting the jumper Rt correctly : Rt * Line adaptation, Rt = 120 ( general case ) Rt * Line adaptation, Rt = 220 Rt * No line adaptation, Rt = Rt * Line adaptation, Rt = 220 Rt * No line adaptation, Rt = Rt 1SXU000023C0202 Rev. A ACTION ON RS 485 Transmitter active / Receiver inactive Transmitter inactive / Receiver active Transmitter inactive / Receiver active E ON/OFF E 12.32 CTRL IN STATUS 0 logic (+3V U +25V) 1 logic (-25V U -3V) High impedance R ON R ILPH RS 232 / FO The Receiver and the Transmitter are activated alternately (never at the same time) depending on the status of the CTRL IN signal. * Line adaptation, Rt = 120 ( general case ) Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Serial data converters Jumper, micro-switch Approximate dimensions ILPH RS 232 / CL ILPH CL / RS 422 - 485 Galvanic isolated converter for current loop Configuration of the micro-switches al co nv er te rs Configuration of the jumper Rt E R INT1 INT2 INT3 S1 S2 S3 S4 Polarization INT4 center of rail CONFIGURATION The various configurations can be selected using the 4 micro-switches located inside the box. center of rail OPERATING MODE ACTIVE OR PASSIVE The Current Loop's Transmission and Reception can be independently in active or passive mode. Select operating mode using S1 and S2. S1 ON S1 S2 S3 S4 S2 OFF Transmission(TxD) ON = Active / OFF = Passive Reception (RxD) ON = Active / OFF = Passive Configuration of amplifiers of the RS 422 - RS 485 (Receiver, Transmitter) line provides greater flexibility of use. The various configurations can be selected using the 2 jumpers (R INT2, E INT1) located inside the box. SIGNAL LEVEL 12 RS 485 LINK ON ONE PAIR INT2 R ON/OFF Jumper R in position R ON/OFF R INT3 E ON/OFF Jumper E in position E ON/OFF E Select signal level 4-20 mA or 0-20 mA. This selection is made using micro-switch S3 S1 S2 S3 S4 ON S3 ON = 4-20 mA / OFF = 0-20 mA OFF Caution : It is not possible to select a 4-20 mA signal when the Reception is in active mode. The Receiver and the Transmitter are activated alternately (never at the same time) depending on the status of the Current Loop Reception signal. RS 485 LINK ON TWO PAIRS R ON Jumper R in position R ON INT2 R ON R E ON/OFF Jumper E in position E ON/OFF INT3 E E ON / OFF Receiver permanently active. Transmitter controlled by the Current Loop Reception signal. RS 422 LINK ON TWO PAIRS LOGIC LEVEL Configuration : LINE AMPLIFIER CONFIGURATION Positive logic or negative logic (0 Logic = 20 mA) (1 Logic = 20 mA) using micro-switch S4 S1 S2 S3 S4 ON S4 ON = (1 = 20 mA) / OFF = (0 = 20 mA) OFF INT2 R ON INT3 E ON E R ON E ON Jumper R in position R ON Jumper E in position E ON The Receiver and the Transmitter are both permanently active. POLARIZATION OF THE RS 422 - RS 485 LINE The line must always be polarized. The ILPH is used to polarize the reception channel : Connection by 1 wire Connection by 1 wire P+ (J1.1) with 5 Viso (J1.4) P- (J1.2) with 0 Viso (J1.3) ADAPTING THE RS 422 - RS 485 LINE ILPH RS 485 / FO The line must always be adapted to the level of the reception channel of each subscriber forming the end of the bus. The ILPH is used to adapt the reception channel by setting the jumper Rt correctly : INT1 * Line adaptation, Rt = 120 (Standard) Rt INT1 * No line adaptation, Rt = Rt ON OFF S1 S2 S3 S4 Legend on off Transmission (TxD) active Transmission(TxD) passive Reception (RxD) active Reception (RxD) passive 4...20 mA Signal 0...20 mA Signal Signal logic 1 = 20 mA Signal logic 0 = 20 mA POLARIZATION The polarization can be configured using the INT4 jumper. INT4 Protection ON Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage INT4 Protection OFF, used if power supply at minimum value (21.6 V). 12.33 1SXU000023C0202 Rev. A rs te er Serial data converters Jumper, micro-switch Approximate dimensions nv na g Si o lc ILPH RS 232 - 485 Ethernet (3 way galvanic isolated) ILPH RS 422 - 485 / RS 422 / - 485 RS 422 - RS 485 DRIVERS CONTROL Channel 2 Configuration of the micro-switch The RS 422 - RS 485 Drivers Control (transmitters and receivers) makes the ILPH easy to use. The control of the 2 channels is completely automatic ; you only have to configure the baud rate needed. INT 3 1 2 3 4 The minimum turn off delay is about 1.5 character/ time from 27 s to 10 ms depending on the baud rate selected. OFF Configuration of the jumper POLARIZATION OF THE RS 422 - RS 485 CONNECTIONS The connections must always be polarized. The ILPH is used to polarize the reception channels : center of rail 1 2 OFF 1 RS 485 LINK ON ONE PAIR Set SW1-1, SW1-3, SW1-6, SW1-7 and SW1-8 to position ON. 12 Action on RS 485 0 Logic (3V U + 25V) Transmitter active / Receiver inactive 1 Logic (-25V U -3V) Transmitter inactive / Receiver active High impedance Transmitter inactive / Receiver active center of rail RS 422 LINK ON TWO PAIRS Set SW1-1, SW1-3, SW1-7 and SW1-8 in position OFF. Set SW1-6 in position ON. Transmitter and receiver are both permanently active. 4 INT 4 3 4 INT 3.1 "ON", polarizes the reception INT 3.2 channel Rx2 5 6 INT 4.1 INT 4.2 "ON", polarizes the reception channel Rx1 ADAPTING THE RS 422 - RS 485 CONNECTIONS Baud rate Configuration of the micro-switch INT 2 INT 1 1 2 3 4 1 2 3 4 OFF The connections must always be adjusted to the level of the reception channel of each subscriber forming the end of the bus. The ILPH is used to adjust the reception channel by setting the micro-switch INT 3.3 and INT 4.3. INT 4 INT 3 Channel 1 Configuration of the micro-switch 1 INT 4 1 2 3 4 5 6 2 3 1 4 2 OFF OFF 3 4 5 6 INT 3.3 and INT 4.3 "ON" 120 set adjustment OFF OFF CAUTION : For RS 232 products running the RTS signal (REQUEST TO SEND), connect RTS to CTRL IN. Otherwise, set SW2-1 to position ON. RS 485 LINK ON TWO PAIRS Set SW1-1, SW1-3, SW1-7 in position OFF. Set SW1-6, SW1-8 in position ON. The receiver is permanently active. The transmitter is controlled by the signal CTRL IN (see table for transmitter operation as a fonction of CTRL IN). 3 OFF The receiver and the transmitter are activated alternately (never at the same time), depending on the status of the CTRL IN signal. CTRL IN STATUS 2 INT 3 BAUD RATE FULL DUPLEX 500 Kb/s 187.5 Kb/s 93.75 Kb/s 38.4 Kb/s 19.2 Kb/s 9.6 Kb/s 4.8 Kb/s 2.4 Kb/s 1.2 Kb/s Nu = not used X = zero INT 1 1234 0000 1111 1111 1111 1111 1111 1110 1100 1000 0000 INT 2 1234 0000 1111 1110 1100 1000 0000 0000 0000 0000 0000 BAUD RATE INT 3 1234 XXX1 XXX0 XXX0 XXX0 XXX0 XXX0 XXX0 XXX0 XXX0 XXX0 INT 4 123456 XXX101 XXX000 XXX000 XXX000 XXX000 XXX000 XXX000 XXX000 XXX000 XXX000 By using the 8 micro-switches inside the box. INT 1 INT 2 1 OFF 2 3 4 1 2 3 4 OFF Permits to define up to 8 transmission speeds and to select the Full Duplex operation mode (RS 422 / RS 422) in addition with the INT 3.4 INT 4.4 and INT 4.5 micro switches. 1 = contact closed 0 = contact open (aus) (off) POLARIZATION OF THE RS 422 - RS 485 LINE The ILPH is used to polarize the reception channel : Set SW1-4 and SW1-5 in position ON. ADAPTING THE RS 422 - RS 485 LINE The line must always be adapted to the level of the reception channel of each subscriber forming the end of the bus. The ILPH is used to adapt the reception channel by setting the jumper SW1-2 correctly : SW1-2 in position ON line adaptation, Rt = 120 (standard) SW1-2 in position OFF no line adaptation, Rt = 12.34 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Serial data converters Technical data al co nv er te rs Technical data Data at Ta = 25 C and rated values, unless otherwise indicated ILPH RS 232 - 485 / Ethernet Power supply 1 Voltage Voltage tolerance Consumption Connections 10...34 V DC, 10...24 V AC -10%, +10% 2 W max coding screw removable connector 0 to 2.5 mm (22-14 AWG) Power supply 2 Voltage Voltage tolerance Consumption Connections Serial link 1: RS 232 Overvoltage protection Baud rate / Transmission distance Connections Serial link 2: RS 485 Voltage Line polarization End line resistance Baud rate / Transmission distance Connections 10...34 V DC -10%, +10% 2 W max screw connector (AWG 20) EIA RS 232 integrated max. 115.2 kbits/s / max. 15 m 2.5 mm screw connector (AWG 20) or male SubD 9 points EIA RS 485 integrated integrated integrated max. 115.2 kbits/s / max. 1200 m coding screw removable connector 0 to 2.5 mm (22-14 AWG) Ethernet link Overvoltage protection Baud rate / Transmission distance Connections integrated 10-100 Mbits/s / max. 100 m without Hub or Switch with CAT5 cable RJ45 connector Traffic indication Voltage Status of signal 12 1 yellow LED 3 green LED (RxD, TxD, LINK), 2 amber or green LED (Speed, Activity) EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Surge Electromagnetic compatibility EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 55022 Other characteristics 750 VDC / 1500 VAC using internal switches or/and software (TELNET or HYPERTERMINAL) 0C ... +60C -20C ... +70C any required snap-on mounting 2.5 mm / stranded with ferrule, 4 mm solid 94 x 22.5 x 100 mm 120 g SubD9 connector GND RX pin 2 = RX TX K pin 3 = TX L M K L M pin 5 = GND J 3 4 5 6 7 K 4 8 TX 3 D 2 GN 1 PW RX R ON M L G 2 H 1 pin 7 = RTS ON Galvanic isolation between serial link / power supply / Ethernet link Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight LIN D D he rn A E D ACTIVITY SPEED et e-ILPH K TX RX Et D E A 0V Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage B2B1+ +24V 24V 12.35 1SXU000023C0202 Rev. A rs te er nv na g Si o lc Serial data converters Technical data Technical data Data at Ta = 25 C and rated values, unless otherwise indicated ILPH RS 232 / RS 422 - 485 (without isolation) Power supply Voltage Voltage tolerance Supply current Connections Serial link 1: RS 232 Overvoltage protection Baud rate / Transmission distance Connections Serial link 2: RS 422-485 Overvoltage protection Baud rate / Transmission distance Connections polarized 24 V DC 8.5...28 V DC 100 mA max removable screw connectors (AWG 20) EIA RS 232 C / CCITT V24 V28 integrated (transil 8 kV 1.2/50 s) max. 38.4 kbits/s / max. 1200 m 2.5 mm screw connectors (AWG 20) EIA RS 485 and EIA RS 422 / CCITT V11 integrated (transil 8 kV 1.2/50 s) max. 38.4 kbits / max. 1200 m 2.5 mm screw connectors (AWG 20) Traffic indication Voltage Connections 1 yellow LED 2 green LED (RxD, TxD) EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility EN 61000-4-2 level 3 6/8 kV EN 61000-4-3 level 310 V/m EN 61000-4-4 level 3 1 kV EN 55022 class B Other characteristics 12 Galvanic isolation between serial link / power supply / Ethernet link Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight no using internal jumper 0C ... +50C -25C ... +80C any required snap-on mounting 2.5 mm / stranded with ferrule, 4 mm solid 88 x 22.5 x 100 mm 100 g RS 422 - RS 485 RS 422 - RS 485 SERIAL LINK (2 wires) Product RS 232 SERIAL LINK (4 wires) Product RS 232 Connector J1 24 V DC power supply Product RS 422-RS 485 *CAUTION : When the RTS Signal is not activated, M terminal (RxD ILPH) has to be connected to L terminal (CTRL IN). 12.36 1SXU000023C0202 Rev. A Connector J1 24 V DC power supply Product RS 422-RS 485 ** CAUTION : To be connected to 2 wired RS 485 only (not possible for 4 wired RS 422). When the RTS Signal is not activated, M terminal (RxD ILPH) has to be connected to L terminal (CTRL IN). Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Serial data converters Technical data al co nv er te rs Technical data Data at Ta = 25 C and rated values, unless otherwise indicated ILPH RS 232 / RS 422 - 485 (isolated) Power supply Voltage Voltage tolerance Supply current Connections Serial link 1: RS 232 Overvoltage protection Baud rate / Transmission distance Connections Serial link 2: RS 422-485 Overvoltage protection Baud rate / Transmission distance Connections polarized 24 V DC 8.5...28 V DC 100 mA max Removable screw connectors (Omniconnect) EIA RS 232 C / CCITT V24 V28 integrated (transil 8 kV 1.2/50s) max. 38.4 kbits/s / max. 15 m 2.5 mm screw connectors (AWG 20) EIA RS 485 and EIA RS 422 / CCITT V11 integrated (transil 8 kV 1.2/50 s) max. 38.4 kbits / max. 1200 m 2.5 mm screw connectors (AWG 20) Traffic indication Voltage Connections 1 yellow LED 3 green LED (RxD, TxD and CTRL-IN) EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility EN 61000-4-2 level 3 6/8 kV EN 61000-4-3 level 310 V/m EN 61000-4-4 level 3 1 kV EN 55022 class B Other characteristics Galvanic isolation between serial link / power supply / Ethernet link Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight 500 V DC using internal jumper 0C ... +50C -25C ... +80C any required snap-on mounting 2.5 mm / stranded with ferrule, 4 mm solid 88 x 22.5 x 100 mm 100 g RS 422 - RS 485 2 WIRE SERIAL LINKS RS 422 - RS 485 4 WIRE SERIAL LINKS RS 232 product RS 232 product Connector J1 Connector J1 24 V DC power supply RS 422-RS 485 product 24 V DC power supply RS 422-RS 485 product * CAUTION : If the RTS signal is not generated, connect M (RxD ILPH) to L (CTRL IN). Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12 ** CAUTION : Only to be connected for RS 485 two pairs (of no use for RS 422 two pairs). If the RTS signal is not generated, connect M (RxD ILPH) to L (CTRL IN). 12.37 1SXU000023C0202 Rev. A rs te er nv na g Si o lc Serial data converters Technical data Technical data Data at Ta = 25 C and rated values, unless otherwise indicated ILPH RS 232 / RS 422 - 485 (3 way galvanic isolated) Power supply Voltage Voltage tolerance Supply current Supply power Connections Serial link 1: RS 232 Overvoltage protection Baud rate / Transmission distance Connections Serial link 2: RS 422-485 Overvoltage protection Baud rate / Transmission distance Connections Polarization for DC model 24...48 V DC 115...230 V AC (50/60 Hz) -15% ... +20% -15% ... +15% 24 V DC<110 mA, 48 V DC<55 mA, 115 V AC<40 mA, 230 V DC<26 mA ~3W ~ 3 VA Removable screw connector (Omniconnect) EA / TIA RS 232 new revision / CCITT V24 V28 integrated (transil 8 kV 1.2/50 s) max. 19,2 kbits/s / max. 15 m / 2500 pF 2.5 mm screw (AWG 20) EIA / TIA RS 232 new revision / CCITT V24 V28 integrated (transil 8 kV 1.2/50s) max. 19.2 kbits/s / max. 15 m 2.5 mm screw (AWG 20) Traffic indication Voltage Connections 1 yellow LED 4 green LED (RxD, RxC/D, TxD, TxC/D) EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility EN 61000-4-2 level 3 6/8 kV EN 61000-4-3 level 3 10 V/m EN 61000-4-4 level 3 1 kV EN 55022 class B Other characteristics 12 Galvanic isolation between RS 232 / Power supply / RSS 422-RS 485 Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight 1,5 kV No 0C ... +50C -25C ... +80C any required snap-on mounting 2.5 mm / stranded with ferrule, 4 mm solid 88 x 22,5 x 100 mm 100 g RS 422 - RS 485 4 WIRE SERIAL LINKS RS 422 - RS 485 2 WIRE SERIAL LINK Product RS 232 Product RS 232 Connector J1 Connector J1 Power supply Power supply Product RS 422 - RS 485 Product RS 422 - RS 485 12.38 1SXU000023C0202 Rev. A *CAUTION : **CAUTION : When the RTS signal is not generated, set SW2-1 in position ON. Only to be connected for RS 485 two pairs (of no use for RS 422 two pairs). If the RTS signal is not generated, set SW2-1 in position ON. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Serial data converters Technical data al co nv er te rs Technical data Data at Ta = 25 C and rated values, unless otherwise indicated ILPH RS 232 / RS 232 Power supply Voltage Voltage tolerance Supply current Supply power Connections Interface 1: RS 232 Overvoltage protection Transmission capacity / Transmission distance Connections Interface 2: RS 232 Overvoltage protection Transmission capacity / Transmission distance Connections DC model polarized 24...48 V DC 115...230 V AC (50/60Hz) -15%...+20% -15%...+15% 24 V DC<155 mA;48 V DC<77 mA;110 V AC<40 mA;230 V DC<26 mA ~ 3.15 W ~ 3.15 VA Removable screw connector (Omniconnect) EIA / TIA RS 232 new revision / CCITT V24 V28 integrated (transil 8 kV 1.2/50 s) max. 19.2 kbits/s / max. 15 m / 2500 pF 2.5 mm screw (AWG 20) EIA / TIA RS 232 new revision / CCITT V24 V28 integrated (transil 8 kV 1.2/50 s) max. 19.2 kbits/s / max. 15 m 2.5 mm screw (AWG 20) Traffic indication Voltage Connections 1 yellow LED 4 green LED (RxD, RxC/D, TxD, TxC/D) EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Galvanic isolation between serial link / power supply / Ethernet link Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight EN 61000-4-2 level 3 6/8 kV EN 61000-4-3 level 3 10 V/m EN 61000-4-4 level 3 1 kV EN 55022 class B 1.5 kV No 0C ... +50C -25C ... +80C any required snap-on mounting 2.5 mm / stranded with ferrule, 4 mm solid 88 x 22.5 x 100 mm 100 g 12 Terminal equipment for ETTD (DTE) data processing (to be connected) Connection not advised according to EIA/TIA 232E standard or Connection not advised according to EIA/TIA 232E standard Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Data transmission end equipment ETCD (DCE) 12.39 1SXU000023C0202 Rev. A rs te er nv na g Si o lc Serial data converters Technical data Technical data Data at Ta = 25 C and rated values, unless otherwise indicated ILPH RS 422 - 485 / RS 422 - 485 Power supply Voltage Voltage tolerance Supply current Connections Interface 1: RS 422-485 Overvoltage protection RS 485 data switching Baud rate / Transmission distance Connections Interface 2: RS 422-485 Overvoltage protection RS 485 data switching Baud rate / Transmission distance Connections DC model polarized 24 V DC +/-15% 120 mA max. Removable screw connector (Omniconnect) EIA / RS 485 and EIA RS 422 / CCITT V11 integrated (transil 8 kV 1.2/50 s) Time switching / Time delay transmission/reception 27 s ...10 ms from 1.2 to 500 kbits/s / max. 1200 m up to 38.4 kbit/s 2.5 mm screw (AWG 20) EIA / RS 485 and EIA RS 422 / CCITT V11 integrated (transil 8 kV 1.2/50 s) Time switching / Time delay transmission/reception 27 s ...10 ms from 1.2 to 500 kbits/s / max. 1200 m up to 38.4 kbit/s 2.5 mm screw (AWG 20) Traffic indication Voltage Connections 1 yellow LED 2 green LED (RxD, TxD, ) EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility EN 61000-4-2 level 3 6/8 kV EN 61000-4-3 level 3 10 V/m EN 61000-4-4 level 3 1 kV EN 55022 class B Other characteristics 12 Galvanic isolation between RS 232 / Power supply / RSS 422-RS 485 Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight 500 V DC using internal DIP switches 0C ... +50C -25C ... +80C any required snap-on mounting 2.5 mm / stranded with ferrule, 4 mm solid 88 x 22.5 x 100 mm 100 g RS 422 - RS 485 4 wire serial link RS 422 - RS 485 2 wire serial link Connector J1 24 V DC power supply Connector J1 24 V DC power supply Caution : The transmission channels of both RS 422 - RS 485 serial link interfaces always have to be independently polarized. 12.40 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Serial data converters Technical data al co nv er te rs Technical data Data at Ta = 25 C and rated values, unless otherwise indicated ILPH RS 232 / FO Power supplies Supply voltage Voltage tolerance Connections Interface 1: RS 232 Protection Max. speed / max. distance Connections Fiber optic interface 2 Type of fiber / Connections Wave length Max. transmission power Max. reception power Max. speed Max. distance Status indication Power supply / Data exchange 24...42 V AC/DC (50/60 Hz) 110...240 V AC/DC (50/60 Hz) -15% ... +10% -15% ... +10% Omniconnect pluggable connector CCITT V.24/DIN 66020- CCITT V.28 DIN 66259-EIA 232 E Integrated (transil 8 kV 1.2/50s) Max. 115.2 kbits/s / max. 15 m / 2500 pF Omniconnect pluggable connector DIN VDE 0888-1 Multimode fiber Glass : ST connector; Plastic : FSMA screw connector Glass : 820 nm; Plastic : 655 nm Glass : 50/125 m : -14.4 db/m; Glass : 62.5/125 m : -14 db/m; Plastic : 980/1000 m : -8 db/m Glass : -28 db/m; Plastic : -20 db/m Max. 115.2 kbits/s Glass : 50/125 m : 3 km; Glass : 62.5/125 m : 4 km; Plastic : 980/1000 m : 40 m 1 green LED / 2 green LEDs (RxD, TxD) EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility EN 61000-4-2 Level 3 6/8 kV EN 61000-4-3 Level 3 10 V/m EN 61000-4-4 Level 3 1 kV EN 55022 Class B Other characteristics Galvanic isolation input / power supply / output Operating temperature Storage temperature Mounting Connections Dimensions (WxDxH) Weight 2.5 kV -20C ... +60C -40C ... +85C Onto DIN Rail (EN 50002) 14 AWG (2.5 mm) fine stranded / 12 AWG (4 mm) rigid 105 x 22.5 x 112 mm / 4.13 x 0.89 x 4.41" 150 g / 0.33 lb 12 (L) (M) TxD Shielding (J H RxD (K) OV G) FO Sending FO Receiving (D) ~(F) OV ~ (E) + Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage (A) (C) Shielding (B) 12.41 1SXU000023C0202 Rev. A rs te er nv na g Si o lc Serial data converters Technical data Technical data Data at Ta = 25 C and rated values, unless otherwise indicated ILPH RS 485 / FO Power supplies Supply voltage Voltage tolerance Connections Interface 1: RS 232 Protection Max. speed / max. distance Connections Fiber optic interface 2 Type of fiber / Connections 1 green LED / 2 green LEDs (RxD, TxD) EN 61000-4-2 Level 3 6/8 kV EN 61000-4-3 Level 3 10 V/m EN 61000-4-4 Level 3 1 kV EN 55022 Class B 2.5 kV -20C ... +60C -40C ... +85C Onto DIN Rail 14 AWG (2.5mm) / fine stranded, 12 AWG (4 mm) rigid 105 x 22.5 x 112 mm / 4.13 x 0.89 x 4.41" 150 g / 0.33 lb D -D + OV Shielding FO Sending 12 Wave length Max. transmission power Max. reception power Max. speed Max. distance Status indication Power supply / Data exchange EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility Other characteristics Galvanic isolation input / power supply / output Operating temperature Storage temperature Mounting Connections Dimensions (WxDxH) Weight 24...42 V AC/DC (50/60 Hz) 110...240 V AC/DC (50/60 Hz) -15% ... +10% -15% ... +10% Omniconnect pluggable connector ISO / IEC 8482 / DIN 66 259-4; EIA 485 Integrated (transil 8 kV 1.2/50s) Max. 1.5 Mbits/s / max. 1200 m (38.4 kbit/s) Omniconnect pluggable connector DIN VDE 0888-1 Multimode fiber Glass : ST connector; Plastic : FSMA screw connector Glass : 820 nm; Plastic : 655 nm Glass : 50/125 m : -14.4 db/m; Glass : 62.5/125 m : -14 db/m; Plastic : 980/1000 m : -8 db/m Glass : -28 db/m; Plastic : -20 db/m Max. 1.5 Mbits/s Glass : 50/125 m : 3 km; Glass : 62.5/125 m : 4 km; Plastic : 980/1000 m : 40 m FO Receiving ~ Shielding OV 12.42 1SXU000023C0202 Rev. A - ~ + Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Si gn Serial data converters Technical data al co nv er te rs Technical data Data at Ta = 25 C and rated values, unless otherwise indicated ILPH RS 422 - 485 (for current loop) Power supply DC model polarized 24 V DC +/-10% 120 mA max. Removable screw connector (Omniconnect) active/passive 0...20 mA / 4...20 mA, mode is settable 0 = 20 mA or 1 = 20 mA, settable max. 38.4 kbit/s / max. 1200 m 2.5 mm screw (AWG 20) EIA RS 485 and EIA RS 422 / CCITT V 11 integrated (transil 8 kV 1.2/50 s) max. 38.4 kbit/s / max. 1200 m 2.5 mm screw (AWG 20) Voltage Voltage tolerance Supply current Connections Interface 1: Current loop Logic level Baud rate / Transmission distance Connections Serial link 2: RS 422/485 Overvoltage protection Baud rate / Transmission distance Connections Traffic indication Voltage Status of signal 1 yellow LED 2 green LED (RxD, TxD) EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility EN 61000-4-2 level 2 4/4 kV EN 61000-4-3 level 3 10 V/m EN 61000-4-4 level 1 0.5 kV EN 55022 class B Other characteristics Galvanic isolation between input / output and power supply / output RS 422-485 power supply Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight depending on Current Loop (active/passive); 500 V DC (active) / 2000 V DC (passive) 500 V DC using internal DIP switches 0C ... +50C -25C ... +80C any required snap-on mounting 2.5 mm / stranded with ferrule, 4 mm solid 88 x 22.5 x 100 mm 100 g 12 RS 422 - RS 485 2 wire serial link RS 422 - RS 485 4 wire serial link CONNECTIONS Current Loop Example of connection with a CL (current Loop) product, Transmission (TxD) in active mode and Reception (RxD) in passive mode. Then, the ILPH must be configured and connected Reception (RxD) in passive mode and Transmission (TxD) in active mode. Note : For any other configuration, see schematic diagram or front sticker of the product. Connector J1 Current Loop 24 V DC power supply Note : The TxD channel of the RS 422 - RS 485 link must be polarized independently too. Connector J1 24 V DC power supply Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 12.43 1SXU000023C0202 Rev. A rs te er nv na g Si o lc Serial data converters Technical data Technical data Data at Ta = 25 C and rated values, unless otherwise indicated ILPH RS 223 / CL Power supply Voltage Voltage tolerance Supply current Connections Serial link 2: RS 232 Logic level Baud rate / Transmission distance Connections BdC serial link 2: RS 422/485 Overvoltage protection Baud rate / Transmission distance Connections DC model polarized 24 V DC +/-10% 120 mA max. Removable screw connector (Omniconnect) EIA RS 232 C / CCITT V 24 V 28 integrated (transil 8 kV 1.2/50 s) max. 38.4 kbit/s / max. 15 m 2.5 mm screw (AWG 20) active/passive 0...20 mA / 4...20 mA mode settable 0=20 mA or 1=20 mA settable max. 38.4 kbit/s / max. 1200 m 2.5 mm screw (AWG 20) Traffic indication Voltage Status signal 1 yellow LED 2 green LED (RxD, TxD) EMC behavior Electrostatic discharge Radiated electromagnetic field Burst Electromagnetic compatibility EN 61000-4-2 level 3 6/8 kV EN 61000-4-3 level 3 10 V/m EN 61000-4-4 level 3 1 kV EN 55022 class B Other characteristics 12 Galvanic isolation between Current loop / RS 232 Galvanic isolation between Current loop / power supply Configuration of the operating mode Operating temperature Storage temperature Mounting DIN rail fixing (EN 50002) Wire size Dimensions (WxDxH) Weight depending on current loop (active/passive) 500 V DC (active) / 2000 V DC (passive) 500 V DC (active) / 2000 V DC (passive) using internal DIP switches 0C ... +50C -25C ... +80C any required snap-on mounting 2.5 mm / stranded with ferrule, 4 mm solid 88 x 22.5 x 100 mm 100 g CONNECTIONS Example of connection with a CL (Current Loop) product, Transmission (TxD) in active mode and Reception (RxD) in passive mode. Then, the ILPH must be configured and connected Reception (RxD) in passive mode and Transmission (TxD) in active mode. 24 V DC power supply CAUTION : For any other configuration, see schematic diagram or front sticker of the product. Current loop 12.44 1SXU000023C0202 Rev. A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage