Power
supplies
Low Voltage Products & Systems 12.A
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12
Signal converters
Index
General information ..................................................................................................................12.1
Analog signal converters ....................................... 12.3 – 12.26
Features and benefits ..........................................................................................................12.3
Application, approvals and marks ........................................................................................12.4
Overview ....................................................................................................................12.5 - 12.6
Ordering details .......................................................................................................12.7 - 12.10
Approximate dimensions....................................................................................................12.11
Technical data ........................................................................................................12.12 - 12.24
Technical diagrams, connection diagrams, approximate dimensions .................................. 12.25
Signal data converters ......................................... 12.27 – 12.44
General information ............................................................................................................12.27
Overview ............................................................................................................................12.28
Ordering details table ......................................................................................................... 12.29
Benefits and advantages....................................................................................................12.30
Ordering details .................................................................................................................12.31
Approximate dimensions........................................................................................12.32 - 12.34
Technical data ........................................................................................................12.35 - 12.44
12 - Signal and data converters
Power
supplies
12.B Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12
Notes
Signal converters
Low Voltage Products & Systems 12.1
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Signal and data converters
Signal and data
Converters
Nowadays various types of data transmis-
sion and interfaces are used in control
processes. Nearly every process includes
a control system that receives data either
by means of analog signals or by data
transmission. The data is then evaluated
and the appropriate parameters are set.
A reliable process control essentially de-
pends on the faultless, untroubled and se-
cure transmission and processing of these
analog signals. There may however, arise
numerous problems which can disturb or
even block an ideal process sequence.
ABB’s range of analog signal converters
are ideally suited when existing electrical
or physical values have to be converted
into proportional standard signals or relay
threshold signals.
The serial data converters from ABB allow
the establishment of a communication
between units with different communication
standards.
In order to assure the process continuity,
existing systems consistently have to be
updated or connected to new devices. If
the communication standard of the exist-
ing system and the connected device are
different, serial data converters make the
establishment of the communication pos-
sible.
Besides the conversion of signals, analog
signal converters and serial data converters
are suited for the amplication, ltering or
separation of analog signals.
Signal converters
12.2 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Signal converters
Low Voltage Products & Systems 12.3
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Analog signal converters
Analog signal
Converters
CC-E range
Universally congurable devices and single-function
devices
Adjustment and operating elements on the front
side
Safe operation by electrical 3-way isolation
Unambiguous and clear connecting terminal mark-
ings
Conversion, measurement and separation of
Standard signals (0-5 V, 0-10 V, 0-20 mA, 4-20 mA)
Temperature signals of RTD sensors (PT 100)
Thermocouple signals (types J and K)
Current measurement signals (0-5 A, 0-20 A AC/
DC)
Characteristics of single-function devices
No adjustment or balancing necessary.
Characteristics of universal devices
The required input and output ranges can be con-
gured by means of directly accessible DIP switches
positioned on the side
Gain adjustment of ±5 % by means of an adjust-
ment potentiometer on the front-side
Offset adjustment of ±5 % by means of adjustment
potentiometers on the front-side
Product range for analog signal processing
CC-U range
8 different standard signal outputs on one device
Input and output side universally congurable
Also available with 2 threshold relay outputs
Adjustment and operating elements on the front
side
Safe operation by electrical 3-way isolation
Plug-in connecting terminals, unambiguously and
clearly marked
Conversion, measurement and separation of
Standard signals
Signals of RTD sensors (PT10, PT100, PT1000)
Thermocouple signals
TRMS values of currents and voltages
Characteristics
The required input and output ranges can be
congured for all devices by means of directly ac-
cessible DIP switches positioned on the side.
Due to the wide input range of the gain and offset
stages all input signals between the minimum
and the maximum input value can be universally
converted to all common output signals.
Devices for DC or AC (50/60 Hz) supply available.
Signal converters
12.4 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Analog signal converters
Application, approvals and marks
Nearly every process includes a control system that receives data
by means of analog signals and then evaluates the data and sets the respective
parameters correspondingly.
When transmitting analog signals numerous problems may arise which can disturb
or even block an ideal behavior of the process.
Below we have listed some processing problems together with the
respective solutions to solve these problems:
Signal conversion
Sometimes the available signals cannot be processed by the controller or the actua-
tor. In this case, signal converters are required to convert the input signal (or different
input signals) to the desired output signal.
Signal amplification
If long lines or high burdens have to be operated, it may be necessary to amplify the
signal. CC analog signal converters require only low input power and provide high
output power.
Thus, there are no restrictions for the converter's position on the line, i.e. it can be
used
for signal refreshing a at the end of the line (low input power)
or for signal amplication b at the beginning of the line
(high output power).
Signal filtering
Particularly on long lines or in rough industrial environments the signals are exposed
to high electromagnetic interferences. The frequency of the coupled interference
signals may be in the range of the common mains frequency (50 Hz) or even much
higher (in case of frequency converters). According to the specic requirements,
analog signal converters are available which provide reliable suppression of those
interferences by means of an input low-pass lter.
Applications for analog signal processing and correct solu-
tion using CC-E and CC-U converters
Signal separation
Protection against overvoltage
The increased use of micro-electronics make controls much more sensitive against
overvoltages, resulting from lightning discharges or switching processes. Suppres-
sion diodes are incorporated in the input of the CC analog signal converters which
enable the converters to arrest overvoltages with low energy level (resulting from
switching processes) by themselves. The products furthermore provide electrical
isolation between input, output and supply circuit for protection of the controller
connected to the output.
Protection against ground loops
If components are used which refer to ground, the measuring signals can be falsi-
ed by a so-called ground loop. In this case, certain parts of the signal are trans-
mitted via earth and not via the analog transmission line, thus causing incorrect
evaluation of the signal. The electrical isolation between the input and the output
disconnects these ground loops and thus enables correct signal transmission.
J existing
G existing for some devices
j pending
Approvals
CC-E/STD
CC-E I/I
CC-U/STD
CC-U/STDR
CC-E/RTD
CC-U/RTD
CC-U/RTDR
CC-E/TC
CC-U/TC
CC-U/TCR
CC-E/I
CC-E IAC/ILPO
CC-U/I
CC-U/V
AUL 508, CAN/CSA C22.2 No.14 JJJJJJJJJJJJJJ
AUL 1604 (Class I, Div 2, hazardous loca-
tions), CAN/CSA C22.2 No.213 GJGJGJGJJ
KCB scheme JJJ
ECCC JJJ
Marks
aCE JJJJJJJJJJJJJJ
bC-Tick JJJJJJJJJJJJJJ
0-10 V0-10 V
100 m 0-20 mA 100 m 4-20 mA
2CDC 282 013 F0206
Controller
e.g. AC500
Measuring sensor
Actuator
1.
Analog signal converter
(e.g. CC-E or CC-U)
2.
Analog signal converter
(e.g. CC-E or CC-U)
Signal converters
Low Voltage Products & Systems 12.5
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Analog signal converters
Overview
CC-E/STD analog signal converter with 3-way electrical isolation
• 2 universally congurable devices (type CC-E/STD)
• 2x10 single-function devices
•"Plug and Work", no adjustment of single-function devices required
Loop-powered current/current isolator without external power supply for analog current signals of 0-20 mA and 4-20 mA
• Electrical isolation between input and output
• Very low internal voltage drop 2.5 V
• Available with one or two independent channels
• Width only 18 mm (1 and 2 channels)
CC-U/STD universal signal converter with 3-way electrical isolation
• More than 120 congurations possible
• Congurable output signal response on input voltage signal interruption (low fail safe / high fail safe)
• Adjustment and operating elements on the front
• Short-circuit proof signal outputs
• Plug-i connecting terminals for inputs, outputs and supply
• Very fast signal transmission enables use in control systems
CC-U/STDR universal signal converter for standard signals, with 2 threshold relay outputs and with 3-way electrical isolation
• Standard signal converter with 7 setting ranges
• 2 threshold relay outputs with one c/o contact each (threshold and respective hysteresis can be adjusted independently from each other)
• Open-circuit or closed-circuit principle congurable by means of a DIP switch
• 2 yellow LEDs for clear status indication of the output relays
• Plug-in connecting terminals for inputs, outputs and supply
CC-E/RTD temperature signal converter for RTD sensors, linearized with 3-way electrical isolation
• 2 universally congurable devices (type CC-E/RTD)
• 2x12 single-function devices
• Plug and Work", no adjustment of single-function devices required
• Temperature signal converter for PT100 sensors
• 2- or 3-wire connection
CC-U/RTD universal signal converter for PT10, PT100, PT1000 temperature sensors
(acc. to IEC 751 and JIS C 16041), linearized with 3-way electrical isolation
• Congurable output signal response on input signal interruption (low / high fail safe)
• Adjustment and operating elements on the front-side
• Short-circuit proof signal outputs
• Plug-in connecting terminals for inputs, outputs and supply
• 2- or 3-wire connection
CC-U/RTDR universal signal converter for temperature and resistance signals,
with 2 threshold relay outputs and 3-way electrical isolation
• Temperature signal converter for PT100 signals (5 ranges up to 800 °C) and variable resistances from 0-380 q
• 2 threshold relay outputs with one c/o contact each (threshold and respective hysteresis can be adjusted independently from each other)
• Open-circuit or closed-circuit principle congurable by means of a DIP switch
• 2 yellow LEDs for clear status indication of the output relays
• Plug-in connecting terminals for inputs, outputs and supply
• 2- or 3-wire connection
Signal converters
12.6 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Analog signal converters
Overview
CC-E/TC analog signal converter for thermocouple signals of the types J and K with 3-way electrical isolation
• 2 universally congurable devices (type CC-E/TC)
• 2x6 single-function devices
•"Plug and Work", no adjustment of single-function devices required
• Temperature signal converter for thermo-couples of the types K, J, T, S, E, N, R, B
• Continuously adjustable voltage signal input 0-10 mV and 0-50 mV
• Differential temperature meas. possible 1)
• Congurable output signal response on input signal interruption (low fail safe / high fail safe)
• Adjustment and operating elements on the front-side
• Short-circuit proof signal outputs
• Plug-in connecting terminals for inputs, outputs and supply
CC-U/TC universal signal converter for thermocouples with 3-way electrical isolation
CC-U/TCR universal signal converter for thermocouples, with 2 threshold relay outputs and 3-way electrical isolation
• Temperature signal converter for thermocouples of the types K, J, T, S
• 2 threshold relay outputs with one change-over contact each (threshold and respective hysteresis can be adjusted independently from each other)
• Open-circuit or closed-circuit principle congurable by means of a DIP switch
• 2 yellow LEDs for clear status indication of the output relays
• Plug-in connecting terminals for inputs, outputs and supply
CC-E/I measuring converter for current signals 0-5 A, 0-20 A, AC/DC with 3-way electrical isolation
• 2 universally congurable devices (type CC-E/I)
• 2x6 single-function devices
•"Plug and Work", no adjustment of single-function devices required
CC-E IAC/ILPO measuring converter without auxiliary power for sinusoidal currents 0-1 A, 0-5 A, output 4-20 mA
• Measuring converter for sinusoidal currents (0-1 A, 0-5 A)
• Measuring range selection by front-face sliding switch
• 4-20 mA output current in proportion to input current
• no additional power supply required
CC-U/I universal measuring converter for RMS values of 0-1 A and 0-5 A, with 3-way electrical isolation
• RMS converter for current signals up to 1 A and up to 5 A of any wave form (DC, DC with superimposed AC components, pure sinusoidal, triangular, phase-angle
controlled, etc. in a measuring range of 0-600 Hz)
• Adjustment and operating elements on the front
• Short-circuit proof signal outputs
• Plug-in connecting terminals for inputs, outputs and supply
CC-U/V universal measuring converter for RMS values of 0-600 V, with 3-way electrical isolation
• RMS converter for voltage signals up to 600 V of any wave form (DC, DC with superimposed AC components, pure sinusoidal, triangular, phase-angle controlled, etc.
in a measuring range of 0-600 Hz)
• Adjustment and operating elements on the front
• Short-circuit proof signal outputs
• Plug-in connecting terminals for inputs, outputs and supply
Signal converters
Low Voltage Products & Systems 12.7
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Standard signal converter
Ordering details
1) 1604 Class I, Div.2 (universal device)
2) CC-E-I/I-1 has 1 channel, CC-E-I/I-1 has 2 channels
3) 3-way electrical isolation
4) with relay output
Description
Standard signal converters of the CC-E range are designed to convert all kind of input standard signals (V, mA) into output standard
signals (V, mA).
Standard signal converters
Supply
voltage
range
Input
signal
Output
signal Type Catalog
number
Weight
(1 pce)
kg (lb)
24 V DC
0-5 V, 0-10 V
0-20 mA,
4-20 mA
0-5 V, 0-10 V
0-20 mA,
4-20 mA
CC-E/STD1) 3) 1SVR011700R0000 0.088 (0.194)
0-10 V 0-10 V CC-E V/V 1SVR011710R2100 0.083 (0.183)
0-20 mA CC-E V/I 1SVR011711R1600 0.084 (0.185)
4-20 mA CC-E V/I 1SVR011712R1700 0.084 (0.187)
0-20 mA 0-10 V CC-E I/V 1SVR011713R1000 0.082 (0.181)
0-20 mA CC-E I/I 1SVR011714R1100 0.084 (0.187)
4-20 mA CC-E I/I 1SVR011715R1200 0.084 (0.185)
4-20 mA 0-10 V CC-E I/V 1SVR011716R1300 0.084 (0.185)
0-20 mA CC-E I/I 1SVR011717R1400
4-20 mA CC-E I/I 1SVR011718R2500 0.084 (0.187)
-10...+10 V -10...+10 V CC-E V/V 1SVR011719R2600 0.082 (0.181)
110-240 V AC 0-5 V, 0-10 V
0-20 mA, 4-20 mA
0-5 V, 0-10 V
0-20 mA, 4-20 mA CC-E/STD 3) 1SVR011705R2100 0.090 (0.198)
0-10 V 0-10 V CC-E V/V 1SVR011720R2300 0.096 (0.212)
0-20 mA CC-E V/I 1SVR011721R1000 0.087 (0.192)
4-20 mA CC-E V/I 1SVR011722R1100 0.091 (0.200)
0-20 mA 0-10 V CC-E V/V 1SVR011723R1200 0.091 (0.200)
0-20 mA CC-E V/I 1SVR011724R1300 0.088 (0.194)
4-20 mA CC-E V/I 1SVR011725R1400
4-20 mA 0-10 V CC-E V/V 1SVR011726R1500 0.096 (0.212)
0-20 mA CC-E V/I 1SVR011727R1600 0.087 (0.192)
4-20 mA CC-E V/I 1SVR011728R2700 0.088 (0.194)
loop powered -10...+10 V -10...+10 V CC-E V/V 1SVR011729R2000 0.086 (0.190)
0-20 mA, 4-20 mA 0-20 mA, 4-20 mA CC-E I/I-12) 1SVR010200R1600 0.038 (0.084)
CC-E I/I-22) 1SVR010201R0300 0.044 (0.097)
24-48 V DC,
110-240 V AC,
100-300 V DC,
24 V AC
refer to table refer to table
2 c/o CC-U/STD 1SVR040000R1700 0.125 (0.276)
1SVR040001R0400 0.126 (0.278)
CC-U/STDR4) 1SVR040010R0000 0.142 (0.313)
1SVR040011R2500
CC-E/I
CC-E V/V
CC-E I/I-2
CC-U/STD
Signal converters
12.8 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABBInc.•888-385-1221•www.abb.us/lowvoltage
12 12
Temperature signal converters
Ordering details
CC-E/RTD
RTD Converters
Supply
voltage
range
Input
signal
Output
signal Type Catalog
number
Weight
(1 pce)
kg(lb)
24VDC refertotable 0-10V,0-20mA,
4-20mA CC-E/RTD1)
1SVR011701R2500
0.091 (0.200)
PT100
0...100 °C 0-10V CC-ERTD/V 1SVR011730R2500 0.084(0.185)
0-20mA CC-ERTD/I 1SVR011731R1200 0.086 (0.190)
4-20mA CC-ERTD/I 1SVR011732R1300
PT100
-50...+50°C 0-10V CC-ERTD/V 1SVR011733R1400 0.083(0.183)
0-20mA CC-ERTD/I 1SVR011734R1500 0.084(0.185)
4-20mA CC-ERTD/I 1SVR011735R1600 0.084(0.187)
PT100
0...300°C 0-10V CC-ERTD/V 1SVR011736R1700 0.084(0.185)
0-20mA CC-ERTD/I 1SVR011737R1000 0.084(0.187)
4-20mA CC-ERTD/I 1SVR011738R2100 0.101
PT100
-50...+250°C 0-10V CC-ERTD/V 1SVR011739R2200 0.084(0.185)
0-20mA CC-ERTD/I 1SVR011740R0700 0.084(0.187)
4-20mA CC-ERTD/I 1SVR011741R2400
110-240VAC refertotable 0-10V,0-20mA,
4-20mA CC-E/RTD 1SVR011706R2200 0.093(0.205)
PT100
0...100 °C 0-10V CC-ERTD/V 1SVR011788R2400 0.086 (0.190)
0-20mA CC-ERTD/I 1SVR011789R2500 0.088 (0.194)
4-20mA CC-ERTD/I 1SVR011790R2200 0.089 (0.196)
PT100
-50...+50°C 0-10V CC-ERTD/V 1SVR011791R1700 0.087(0.192)
0-20mA CC-ERTD/I 1SVR011792R1000 0.089 (0.196)
4-20mA CC-ERTD/I 1SVR011793R1100
PT100
0...300°C 0-10V CC-ERTD/V 1SVR011794R1200 0.087(0.192)
0-20mA CC-ERTD/I 1SVR011795R1300 0.089 (0.196)
4-20mA CC-ERTD/I 1SVR011796R1400
PT100
-50...+250°C 0-10V CC-ERTD/V 1SVR011797R1500 0.086 (0.190)
0-20mA CC-ERTD/I 1SVR011798R2600 0.089 (0.196)
4-20mA CC-ERTD/I 1SVR011799R2700 0.088 (0.194)
24-48VDC,
100-300VDC,
110-240VAC,
24 V AC
refertotable refertotable
2c/o CC-U/RTD 1SVR040002R0500 0.126(0.278)
1SVR040003R0600 0.128 (0.282)
CC-U/RTDR
3)
1SVR040012R2600 0.146(0.322)
1SVR040013R2700 0.148(0.326)
CC-U/RTD
1)1604ClassI,Div.2(universaldevice)
2)CC-E-i/i-1has1channel;CC-E-1/1-1has2channels
3)withrelayoutput
Signal converters
Low Voltage Products & Systems 12.9
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Thermocouple converters
Ordering details
CC-E TC
Thermocouple converters
Supply
voltage
range
Input
signal
Output
signal Type Catalog
number
Weight
(1 pce)
kg (lb)
24 V DC thermocouple types
J and K
0-10 V, 0-20 mA,
4-20 mA CC-E/TC1) 1SVR011702R2600 0.089 (0.196)
type J
0...600 °C 0-10 V CC-E TC/V 1SVR011750R0100 0.087 (0.192)
0-20 mA CC-E TC/I 1SVR011751R2600 0.084 (0.187)
4-20 mA CC-E TC/I 1SVR011752R2700 0.102
type K
0...1000 °C 0-10 V CC-E TC/V 1SVR011753R2000 0.084 (0.185)
0-20 mA CC-E TC/I 1SVR011754R2100
4-20 mA CC-E TC/I 1SVR011755R2200 0.086 (0.190)
110-240 V AC thermocouple
types J and K
0-10 V, 0-20 mA,
4-20 mA CC-E/TC 1SVR011707R2300 0.088 (0.194)
type J
0...600 °C 0-10 V CC-E TC/V 1SVR011760R0300 0.084 (0.187)
0-20 mA CC-E TC/I 1SVR011761R2000 0.088 (0.194)
4-20 mA CC-E TC/I 1SVR011762R2100 0.1 (0.220)
type K
0...1000 °C 0-10 V CC-E TC/V 1SVR011763R2200 0.086 (0.190)
0-20 mA CC-E TC/I 1SVR011764R2300 0.088 (0.194)
4-20 mA CC-E TC/I 1SVR011765R2400 0.086 (0.190)
24-48 V DC,
100-300 V DC,
110-240 V AC,
24 V AC
refer to table refer to table
2 c/o CC-U/TC 1SVR040004R0700 0.130 (0.287)
1SVR040005R0000 0.128 (0.282)
CC-U/TCR 1) 1SVR040014R2000 0.145 (0.320)
1SVR040015R2100
1) with relay output
Signal converters
12.10 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Measuring converters
Ordering details
Measuring converters
Supply
voltage
range
Input
signal
Output
signal Type Catalog
number
Weight
(1 pce)
kg (lb)
24 V DC
0-5 A,
0-20 A, AC/DC
0-10 V, 0-20 mA,
4-20 mA CC-E/I 1) 1SVR011703R2700 0.096 (0.212)
0-5 A,
0-20 A, AC
0-10 V CC-E IAC/V 1) 1SVR011770R0500 0.090 (0.198)
0-20 mA CC-E IAC/I 1) 1SVR011771R2200 0.092 (0.203)
4-20 mA CC-E IAC/I 1) 1SVR011772R2300
0-10 V CC-E IDC/V 1) 1SVR011773R2400 0.092 (0.207)
0-20 mA CC-E IDC/I 1) 1SVR011774R2500 0.091 (0.200)
4-20 mA CC-E IDC/I 1) 1SVR011775R2600 0.093 (0.205)
110-240 V AC
0-5 A,
0-20 A, AC/DC
0-10 V, 0-20 mA,
4-20 mA CC-E/I 1) 1SVR011708R0400 0.099 (0.218)
0-5 A,
0-20 A, AC
0-10 V CC-E IAC/V 1) 1SVR011780R1100 0.092 (0.203)
0-20 mA CC-E IAC/I 1) 1SVR011781R0600 0.092 (0.207)
4-20 mA CC-E IAC/I 1) 1SVR011782R0700 0.095 (0.209)
0-10 V CC-E IDC/V 1) 1SVR011783R0000 0.093 (0.205)
0-20 mA CC-E IDC/I 1) 1SVR011784R0100 0.095 (0.209)
4-20 mA CC-E IDC/I 1) 1SVR011785R1100
250 V AC 0-1 A, 0-5 A, AC 4-20 mA
CC-E IAC/ILPO
2) 1SVR010203R0500 0.052 (0.115)
24-48 V DC,
100-300 V DC,
110-240 V AC,
24 V AC
refer to table refer to table
CC-U/I 3)
1SVR040006R0100 0.128 (0.282)
1SVR040007R0200 0.127 (0.280)
CC-U/V 4) 1SVR040008R1300 0.128 (0.282)
1SVR040009R1400
CC-E IAC/ILPO
CC-U/I
5) with relay output
6) for sinusoidal currents
7) for current RMS values
8) for voltage RMS values
Signal converters
Low Voltage Products & Systems 12.11
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Analog signal converters
Accessories
Approximate dimensions
Accessories
For type Width in mm
Type Catalog number Pkg
qty
Weight
(1 pce)
g (oz)
CC-U 22.5 ADP.01 1SVR430029R0100 118.4 (0.65)
CC-U MAR.01 1SVR366017R0100 10 0.19 (0.007)
CC-U 22.5 COV.01 1SVR430005R0100 15.2 (0.18)
2CDC 252 187 F0005
4,5
62,5
60
10 11,5
22,5
.177”
2.46”
2.36”
.394”
.886”
.453”
2CDC 252 185 F0005
22,5
68,5
7
3,5
.886”
2.70 ”
.138”
.275”
front-to-back
size 107
ADP.01
20
3A11
8
.315”
.787”
2CDC 252 186 F0005
MAR.01 Sealable cover - COV.01
Approximate dimensions
Signal converters
12.12 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Analog signal converters
Technical data
812 43 567
0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V
0...10 V
0...20 mA
4...20 mA
0...5 V
0...10 V
0...20 mA
4...20 mA
Input Output Switch
ON
Legend
OFF
CC-E/STD, CC-E x/x (universal devices)
DIP switch settings
*) Detection of input voltage signal interruptions:
If the input signal circuit is interrupted, the output signal chang-
es to the adjusted minimum value (low fail safe) or maximum
value (high fail safe).
If "No fail safe" is congured, input signal interruptions are
not detected.
43215876
0...8 V
0...20 mA
4...20 mA
10...50 mA
20...4 mA
20...0 mA
0...50 mV
0...100 mV
0...250 mV
0...500 mV
0...1 V
0...5 V
-10...+10 V
0...125 mV
1...5 V
0...10 V
2... 10 V
-11...+11 V
10...0 V
100...0 mV
0...1 mA
-55...+55 mA
3...4
2...4
4...5
0...1
4...5
4...2
A...D
4...5
0...1
7...9
3...4
5...7
0
3...4
7...9
2
2...4
0
2
4...5
A...D
4...6
3
3
4
1
4
3
C
5
1
8
3
6
0
3
8
2
3
0
2
5
B
5
6
4
0
0
D
D
0
0
B...F
5...7
3...4
-
-
-
-
-
-
B...F
Switch 1
Input
2.5...7.5 V
3.33...9.99 V
High fail safe *)
Gain Coarse
Type
Potentiometer
0...2.5 V
-22.5...+22.5 mV
-0.45...+0.45 mA
Low faile safe *)
No fail safe *)
12 4356
-10...-2 V
-5...-1 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...800 µA
0...8 mA
0...400 µA
125...625 µA
166...833 µA
2...10 mA
100...500 µA
0...666 µA
0...16 mA
0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...8 V
0...4 V
Switch 2
Output
1.25...6.25 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
0...0.5 mA
0...13.33 mA
2.5...12.5 mA
3.33...16.66 mA
0.2...1 mA
OFF
Legend
no inuence
ON
CC-U/STD
DIP switch settings Adjustment range
Burden
R M 1.0 kq
Burden
R m 500 q
supply
Wiring instruction
Pot.
G
H
J
Burden
R M 4.7 kq
Burden
R m 600 q
supply
+ 2.5 V
Wiring instruction
OUT [%]
IN [%]
SW1.4 = +100 %
SW1.5 = +50 %
100
90
80
70
60
50
40
30
20
10
10 20 30 40 50 60 70 80 90 100
1
Offset remote poti
SW1.6 = +22.5 %
Gain
“gain-coarse”
und
“gain-ne”
Signal converters
Low Voltage Products & Systems 12.13
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
CC-U/STDR with relay output
DIP switch settings
Function diagrams
OFF
Legend
no inuence
ON
12 4356
0...0 V
0...5 V
0...1 V
-10...+10 V
1...5 V
0...20 mA
4...20 mA
Switch
Input
Output
Closed-circuit principle
Open-circuit principle
Wiring instruction
Value R1
Value R2
Threshold Hysteresis
supply
Switching points of the output relay depending on the input range,
configuration open-circuit principle
OUT
11-14
11-12
21-24
21-22
R1
R2
IN [%]
100
90
80
70
60
50
40
30
20
10
0
Hysteresis R1
5-50 % of
threshold
value R1
Threshold value R1
2-100 %
of input range
Threshold value R2
2-100 %
of input range
Hysteresis R2
5-50 % of
threshold
value R2
Actual value
Switching points
21-24
21-22
11-14
11-12
R2
R1
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Temperature
Closed-circuit principle
21-24
21-22
11-14
11-12
R2
R1
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Temperature
Open-circuit principle
OFF
Legend
no inuence
ON
12 4356
0...300 °C
0...100 °C
0...500 °C
-50...+50 °C
-50...+250 °C
-50...+450 °C
High fail safe
Low fail safe
0...10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
0-10 V
0-20 mA
4-20 mA
Input Output Switch
CC-E/RTD
DIP switch settings
J
H
G
Burden
R M 1.0 kq
Burden
R m 500 q
Wiring instruction
CC-E IAC/ILPO
Wiring instruction
Analog signal converters
Technical data
Signal converters
12.14 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Analog signal converters
Technical data
*) Detection of input signal interruptions:
If the input signal circuit is interrupted,
the output signal changes to the ad-
justed minimum value (low fail safe) or
maximum value (high fail safe).
CC-U/RTD
DIP switch settings
Wiring instruction
OFF
Legend
no inuence
ON
12 4356124356
PT10
PT100
PT1000
0...500 °C
0...550 °C
0...600 °C
0...650 °C
0...700 °C
0...750 °C
0...800 °C
0...850 °C
0...50 °C
0...60 °C
0...70 °C
0...80 °C
0...90 °C
0...100 °C
0...200 °C
0...400 °C
0...300 °C
0...500 °C
0...10 °C
0...20 °C
0...30 °C
0...40 °C
0...50 °C
0...60 °C
F
E
D
C
B
A
9
8
F
E
B
A
9
8
3
1
2
0
8
3
2
1
0
0
-
-
Type Range
Switch 1 Switch 2Input
Low fail safe *)
High fail safe *)
Gain
Coarse
12 4356
-10...-2 V
-5...-1 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...800 µA
0...8 mA
0...400 µA
125...625 µA
166...833 µA
2...10 mA
100...500 µA
0...666 µA
0...16 mA
0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...8 V
0...4 V
Switch 3
Output
1.25...6.25 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
0...0.5 mA
0...13.33 mA
2.5...12.5 mA
3.33...16.66 mA
0.2...1 mA
Wiring instruction
J
H
G
Burden
R M 4.7 kq
Burden
R m 600 q
supply
Resistance of PT10, PT100 and PT1000 sensors depending on the temperature
PT1000
PT100
PT10
Resistance [q]
Temperature [°C]
Characteristic curves
CC-E I/I-2CC-E I/I-1
100 q m RL m 500 q
UL
C
D
F
E
IN
IN
OUT
OUT
Channel 1
input
0-20 mA or
4-20 mA
Channel 1
output
0-20 mA or
4-20 mA
100 q m RL m 500 q
100 q m RL m 500 q
UL
UL
C
D
F
E
A
B
H
G
IN
IN
IN
IN
OUT
OUT
OUT
OUT
Channel 1
input
0-20 mA or
4-20 mA
Channel 2
input
0-20 mA or
4-20 mA
Channel 1
output
0-20 mA or
4-20 mA
Chanel 2
output
0-20 mA or
4-20 mA
CC-E I/I-1 and CC-E I/I-2
Signal converters
Low Voltage Products & Systems 12.15
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
CC-U/RTDR with relay output
DIP switch settings
OFF
Legend
no inuence
ON
12 4356
0...100 °C
0...200 °C
0...400 °C
0...600 °C
0...800 °C
Switch
Input PT100
Output
Closed-circuit principle
Open-circuit principle
Wiring instruction
u
G
J
H
KM
B (22)
C (21)
A (24)
E (12)
F (11)
D (14)
R1
R2
Value R1
Value R2
Threshold Hysteresis
supply
Switching points of the output relay depending on the input range,
configuration open-circuit principle
OUT
11-14
11-12
21-24
21-22
R1
R2
100
90
80
70
60
50
40
30
20
10
0
IN [%]
800
700
600
500
400
300
200
100
50 100 150 200 250 300 350 400
Resistance [q]
Temperature u [°C]
Hysteresis R1
5-50 % of
threshold
value R1
Threshold value R1
2-100 %
of input range
Threshold value R2
2-100 %
of input range
Hysteresis R2
5-50 % of
threshold
value R2
Actual value
Switching points
Function diagrams
21-24
21-22
11-14
11-12
R2
R1
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Temperature
Closed-circuit principle
21-24
21-22
11-14
11-12
R2
R1
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Temperature
Open-circuit principle
Wiring instruction CC-E/TC and CC-E/I
Burden
R M 1.0 kq
Burden
R m 500 q
supply
DIP switch settings CC-E/TC
OFF
Legend
no inuence
ON
12 4356
TC-J:
0...600 °C
TC-K:
0...1000 °C
High fail safe
Low fail safe
0...10 V
0...20 mA
4...20 mA
0...10 V
0...20 mA
4...20 mA
Input Output Switch
CC-E/TC, CC-E/I
DIP switch settings CC-E/I
ON
Legend
OFF
12 4356
I - DC
I - AC
I - AC
I - DC
I - AC
I - DC
0...10 V
0...20 mA
4...20 mA
Input Output Switch
Select input range by terminals
Input range 5 A
Connected lines
Used terminals
Terminal marking
Input range 20 A
Connected lines
Used terminals
Terminal marking
Input range selection - CC-E/I
Analog signal converters
Technical data
Signal converters
12.16 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
CC-U/I
DIP switch settings
OFF
Legend
no inuence
ON
12 4356
-10...-2 V
-5...-1 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...800 µA
0...8 mA
0...400 µA
125...625 µA
166...833 µA
2...10 mA
100...500 µA
0...666 µA
0...16 mA
0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...8 V
0...4 V
Switch
Output
1.25...6.25 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
0...0.5 mA
0...13.33 mA
2.5...12.5 mA
3.33...16.66 mA
0.2...1 mA
CC-U/V
DIP switch settings
OFF
Legend
no inuence
ON
12 4356
-10...-2 V
-5...-1 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...800 µA
0...8 mA
0...400 µA
125...625 µA
166...833 µA
2...10 mA
100...500 µA
0...666 µA
0...16 mA
0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...8 V
0...4 V
Switch
Output
1.25...6.25 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
0...0.5 mA
0...13.33 mA
2.5...12.5 mA
3.33...16.66 mA
0.2...1 mA
Wiring instruction
Burden
R M 4.7 kq
Burden
R m 600 q
supply
Wiring instruction
Burden
R M 4.7 kq
Burden
R m 600 q
supply
0...100 V
0...150 V
0...250 V
0...300 V
0...400 V
0...600 V
0...450 V
0...550 V
1
2
3
4
5
8
6
7
Switch
position
Selecting input range by
front-face rotary switch
Input range selection
JHG
JHG
5 A1
AC
5 A1
AC
Select input range by terminals
Input range 1 A
Connected lines
Used terminals
Terminal marking
Input range 5 A
Connected lines
Used terminals
Terminal marking
Input range selection
RMS measurement and conversion of a phase-angle controlled voltage signal L1 = 230 V
U(t) [V]
INUeff [V]
OUT [%]
0 50 100
300
0
-300
Offset w20 %
Gain w15 %
resulting
RMS value
operating angle
Example of application
RMS measurement and conversion of a current signal
I(t) [A]
IN [%]
OUT [%]
0 50 100
t
5
4
3
2
1
0
-1
-2
-3
-4
-5
Offset w20 %
Gain w15 %
resulting
RMS value
Example of application
Analog signal converters
Technical data
Signal converters
Low Voltage Products & Systems 12.17
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
*) Detection of input signal
interruptions:
If the input signal circuit is inter-
rupted, the output signal changes to
the adjusted minimum value
(low fail safe) or maximum value
(high fail safe).
CC-U/TC
DIP switch settings
12 4356
-10...-2 V
-5...-1 V
-8...0 V
-4...0 V
0...1 mA
0...20 mA
4...20 mA
0...10 mA
0...800 µA
0...8 mA
0...400 µA
125...625 µA
166...833 µA
2...10 mA
100...500 µA
0...666 µA
0...16 mA
0...5 V
0...10 V
1...5 V
2...10 V
-10...+10 V
-5...+5 V
-10...0 V
-5...0 V
0...8 V
0...4 V
Switch 3
Output
1.25...6.25 V
0...6.66 V
-10...+3.33 V
-5...+1.66 V
-7.5...+2.5 V
-3.75...+1.25 V
1.66...8.33 V
-6.66...+6.66 V
-3.33...+3.33 V
0...0.5 mA
0...13.33 mA
2.5...12.5 mA
3.33...16.66 mA
0.2...1 mA
OFF
Legend
no inuence
ON
12 4356124356
R
B
mV
N
K
J
T
S
E
0-100...900 °C
0-250...1350 °C
0-100...750 °C
0-100...400 °C
-150-0...400 °C
0-250...1550 °C
0-100...700 °C
0-200...1000 °C
0-100...650 °C
0-200...1300 °C
0-250...1350 °C
0-450...1700 °C
0-700...1750 °C
0-2...10 mV
0-10...50 mV
Type Range
Switch 1 Switch 2Input
Low fail safe *)
High fail safe *)
1)
Wiring instruction
without cold-junction compensation:
switch SW2.2 = OFF
Burden
R M 4.7 kq
Burden
R m 600 q
supply
Thermocouple voltages depending on the temperature
Typ T
Typ N
Typ K
Typ J
Typ E
Typ R
Typ S
Typ B
-250
-200
-150
-100
-50
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
1150
1200
1250
1300
1350
1400
1450
1500
1550
1600
1650
1700
1750
1800
80000
75000
70000
65000
60000
55000
50000
45000
40000
35000
30000
25000
20000
15000
10000
5000
0
-5000
-10000
-15000
Temperatur [°C]
Thermoelement-Spannung [µV]
Characteristic curve
Analog signal converters
Technical data
Signal converters
12.18 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Switching points of the output relay depending on the input range,
configuration open-circuit principle
Typ T
Typ J
Typ K
Typ S
IN [%]
100
0OUT
11-14
11-12
21-24
21-22
R1
R2
7000
6500
6000
5500
5000
4500
4000
3500
3000
2500
2000
1500
1000
500
0
-500
-1000
-1500
-275
-175
-75
25
125
225
325
425
525
625
725
825
925
1025
1125
1225
1325
1425
1525
1625
1725
1825
Temperature [°C]
Thermocouple voltage [µV]
Threshold value
R2 = 400 °C
Release hysteresis
Threshold value
R1 = 1000 °C
Release hysteresis
Switching points
CC-U/TCR with relay output
DIP switch settings
OFF
Legend
no inuence
ON
12 4356
S
J
K
T
0...240 °C
0...480 °C
0...1200 °C
0...250 °C
0...500 °C
0...1350 °C
-150...+120 °C
0...220 °C
0...400 °C
0...210 °C
0...380 °C
0...860 °C
0...1550 °C
Type Range
SwitchInput
Output
Closed-circuit principle
Open-circuit principle
Wiring instruction
Value R1
Value R2
Threshold Hysteresis
supply
Function diagrams
21-24
21-22
11-14
11-12
R2
R1
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Temperature
Closed-circuit principle
21-24
21-22
11-14
11-12
R2
R1
R1 Threshold value
R1 Hysteresis
R2 Hysteresis
R2 Threshold value
Temperature
Open-circuit principle
Analog signal converters
Technical data
Signal converters
Low Voltage Products & Systems 12.19
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Type CC-E/STD CC-E/RTD 3) CC-E/TC
Input circuits - Analog inputs J-G-H Current Voltage Temperature sensors Thermocouples
(IEC 584-1 and 2)
Input signal Standard signals PT100 TC.K, TC.J
Rated input range 0...20 mA /
4...20 mA
0...5 V /
0...10 V /
-10...+10 V
-50...+500 °C
TC.K: 0...1000 °C,
TC.J: 0...600 °C
Limitation of input signals +55 mA ± 11 V
Inuence of line resistance -< 0.01 %/q< 0.5 % / 100 q
Gain adjustment range ± 5 % (universal devices)
Offset adjustment range ± 5 % (universal devices)
Input impedance 50 q1 Mq- -
Suppression at 50 Hz - - > 35 dB
Common-mode rejection - 100 dB
Output circuits - Analog outputs D-F, A-C Current Voltage
Output signal 0-20 mA, 4-20 mA 0-5 V, 0-10 V
Output burden 500 q 1.0 Kq
Accuracy 1) ± 0.5 % of full-scale
Residual ripple < 0.5 %
Response time 200 µs 10 ms
Transmission frequency 2 kHz 80 Hz 2 Hz (up to -3 dB)
Reaction to input circuit interruption High fail safe: Output voltage > 115 % of measuring range
2)
Low fail safe: Output voltage < -0.6 V, output current =
0 mA
Supply circuits K-M DC versions AC versions
Supply voltage 24 V DC 110-240 V AC - 50/60 Hz
Supply voltage tolerance -15...+15 % -15...+10 %
Power consumption 1.5 W typ. 1.5 VA typ.
Indication of operational states
Rated control supply voltage USU: green LED
General data
Ambient temperature range operation / storage 0...+60 °C / -20...+80 °C
Temperature coefcient ± 500 ppm/°C
Degree of protection (DIN 40050) IP20
Mounting position ventilation slots on top and bottom
Mounting DIN rail (IEC/EN 60715), snap-on mounting
Electrical connection
Wire size rigid 0.2-4 mm2 (24-12 AWG)
ne-strand with(out) wire end ferrule
0.2-
2.5 mm2 (24-14 AWG)
Stripping length 7 mm (0.28 inch)
Tightening torque 0.5 Nm (4.4 lb.in)
Electromagnetic compatibility
Interference immunity EN 61000-6-2
electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
electromagnetic eld
(HF radiation resistance)
IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)
powerful impulses (Surge) IEC/EN 61000-4-5 ±2 kV / ±1 kV
HF line emission IEC/EN 61000-4-6 10 V
Interference emission EN 61000-6-4 Class B
Isolation data
Test voltage between all isolated circuits 2.5 kV AC
Rated insulation voltage - - -
1) Includes non-linearity and factory setting, inuenced by supply voltage and output load.
2) Only -/RTD and -/TC: Single-function devices respond with Low fail safe to input signal interruptions.
3) When connecting a 2-wire sensor, the terminals J and H have to be jumpered.
Analog signal converters
Technical data
Signal converters
12.20 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Type CC-E I/I
Input circuits - Analog inputs Current
Input current IIN 0-20 mA, 4-20 mA
Min. input current < 100 µA
Max. input current 50 mA1) (VIN < 18 V)
Input voltage UIN < 2.5 V + (IIN x RL)
Input voltage drop Ui< 2.5 V (20 mA, RL = 0 q)
Max. input voltage 18 V1) (IIN < 50 mA)
Output circuits
Output current IOUT 0-20 mA, 4-20 mA
Output load RL0-500 q
Output voltage UOUT IOUT x RL
Residual ripple < 20 mVpp (500 q, 20 mA)
Response time (0-100 %) < 15 ms (0-500 q, 20 mA),
< 5 ms (500 q, 20 mA, 25 °C)
Accuracy 0.1 % of full-scale (20 mA)
Load inuence (0-500 q) 0.05 % / 100 q,
-0.1 % / 100 q (25 °C)
General data
Width of the enclosure 18 mm
Weight 1 channel approx. 0.037 kg (0.082 (0.181) lb)
2 channel approx. 0.044 (0.097) kg (0.097 lb)
Mounting position any
Degree of protection enclosure / terminals IP20 / IP20
Ambient temperature range operation / storage -25...+60 °C / -40...+85 °C
Temperature coefcient < 50 ppm / °C
Mounting DIN rail (IEC/EN 60715)
Electrical connection
Wire size rigid 0.2-4 mm2 (24-12 AWG)
ne-strand with(out) wire end ferrule
0.2-
2.5 mm2 (24-14 AWG)
Stripping length 7 mm (0,28 inch)
Tightening torque 0.5 Nm (4.4 lb.in)
Standards
Product standard EN 50178
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Electromagnetic compatibility
Interference immunity EN 61000-6-2
electrostatic discharge (ESD) EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
electromagnetic eld (HF radiation resistance) EN 61000-4-3 10 V/m
fast transients (Burst) EN 61000-4-4 Level 3 (±2 kV / 5 kH)
powerful impulses (Surge) EN 61000-4-5 ±2 kV / ±1 kV
HF line emission EN 61000-4-6 10 V
magnetisches Feld EN 61000-4-8 30 A/m
Interference emission EN 61000-6-4
Radiated noise EN 55011 Class B
Operational reliability (EN 68-2-6) 4 g
Mechanical resistance (EN 68-2-6) 10 g
Environmental testing (IEC 68-2-30 Db) 24 h cycle, 55 °C, 93 % rel., 96 h
Isolation data
Insulation voltage input / output 500 Veff / 50 Hz
Insulation voltage between channels 5 kVeff / 50 Hz
(device with 2 channels)
Pollution category 2
Overvoltage category II
1) The input parameters have to be limited to the indicated maximum values.
Analog signal converters
Technical data
Signal converters
Low Voltage Products & Systems 12.21
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Type CC-U/STD CC-U/RTD 3) CC-U/TC
Input circuits - Analog inputs J-G-H
Current Voltage
Po-
tentio-
meter
Temperature sensors Thermocouples
(IEC 584-1 and 2)
Input signal 0-20 mA
4-20 mA
10-50
mA
0-1 mA
0-100
mV
0-1 V
0-5 V
1-5 V
0-10 V
2-10 V
± 10 V
470 q -
1 Mq 2)
PT10, PT100, PT1000
(IEL 751 and JICC 1604)
TC.K
TC.T
TC.E
TC.R
TC.J
TC.S
TC.N
TC.B
Limitation of input signals ± 55 mA ± 11 V - -
Rated input range
---
Max. temperature adjust-
able:
6-60 °C for PT1000
50-500 °C for PT100
500-850 °C for PT10
refer to temperature specs.
of individual thermocouples
Inuence of line resistance --- 0.015 °C/q< 0.01 % / 100 q
Gain adjustment range
(universal devices)
0.9-
110 mA
45 mV -
22 V - see DIP switch settings
Offset adjustment range (universal devices) -137.5...+62.5 % ± 5 % ± 10 %
Input impedance for different ranges - -
without detection of inp ut signal interruption
51 q6 Mq3 Gq- -
with detection of input signal interruption
51 q3.5 Mq9.5 Gq- -
Suppression at 50 Hz - - - - > 40 dB
Common-mode rejection - - - 120 dB 105 dB
Output circuits - Analog outputs
D-F, A-C Current Voltage
Output signal 0-20 mA, 4-20 mA 0-5 V, 1-5 V, 0-10 V, 2-10 V, ± 10 V
Output burden 600 q 4.7 Kq
Accuracy 1) ±0.1 % of full-scale ±0.2 % of full-scale ±0.1 % of full-scale
Residual ripple - < 0.15 % -
Response time 200 µs 10 ms 200 ms
Transmission frequency 1 kHz 80 Hz 2 Hz (to -3 dB)
Supply circuits K-M
Rated supply voltage 24-48 V DC 110-240 V AC
Supply voltage range 24-48 V DC / 24 V AC 110-240 V AC / 100-300 V DC
Supply voltage tolerance DC: -15...+15 % AC: -15...+10 %
Rated frequency 0 Hz or 50/60 Hz
Power consumption 2 W at 24 V DC 4.5 VA at 230 V AC
Indication of operational states
Supply voltage U: green LED
General data
Ambient temperature range operation / storage -20...+60 °C / -40...+80 °C
Temperature coefcient ±150 ppm/°C ±250 ppm/°C ±200 ppm/°C at min. offset
±400 ppm/°C at max. offset
Mounting position any
Mounting DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter
Electrical connection
Wire size rigid plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
ne-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
Stripping length 7 mm (0.28 inch)
Tightening torque 0.4 Nm (3.5 ib.in)
Electromagnetic compatibility
Interference immunity EN 61000-6-2
electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
electromagnetic eld (HF radiation resistance) IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)
powerful impulses (Surge) IEC/EN 61000-4-5 2 kV / 1 kV
HF line emission IEC/EN 61000-4-6 10 V
Interference emission
EN 61000-6-4 Class B
Isolation data
Isolation test (between all isolated circuits) 1.5 kV
Test voltage (between all isolated circuits) 1.5 kV / 50 Hz
1) Includes non-linearity and factory setting, inuenced by supply voltage and output load.
2) Detection of an input signal break (fail safe) and resistance > 10 kq results in a linearity of 0,2 %.
3) When connecting a 2-wire sensor, the terminals J and H have to be jumpered.
Analog signal converters
Technical data
Signal converters
12.22 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Type CC-U/STDR CC-U/RTDR 1) CC-U/TCR
Input circuits - Analog inputs J-H Current Voltage Temperature sensors Thermocouples
(IEC 584-1 and 2)
Measuring signal / input range 0-20 mA
4-20 mA
0-1 V /
1-5 V
0-10 /
±10 V
PT100 TC.K, TC.J
TC.T, TC.S
Input resistance approx.
50 q
approx. 1,5
Mq
Adjustable threshold 2-100 % of selected input range
Adjustable hysteresis 5-50 % of threshold
Repeat accuracy (constant parameters) ±0.5 % of full-scale
Output circuits - Relay outputs E-D-F, B-C-A Relay, 2 c/o contacts
Rated switching voltage 250 V AC
Rated switching current AC12 (resistive) 230 V 4 A
AC15 (inductive) 230 V 3 A
DC12 (resistive) 24 V 4 A
DC13 (inductive) 24 V 2 A
AC rating
(UL 508)
Utilization category (Control Circuit Rating Code) B 300
max. rated operational voltage 300 V AC
max. continuous thermal current at B 300 5 A
max. making/breaking apparent power at B 300 3600/360 VA
Minimum switching voltage 12 V
Minimum switching current / power 10 mA / 0.6 VA (W)
Response time 10 ms
Mechanical lifetime 30 x 106 switching cycles
Electrical lifetime at AC12, 230 V, 4 A 0.1 Mio. switching cycles
Supply circuits K-M
Rated supply voltage 24-48 V DC 110-240 V AC
Supply voltage range 24-48 V DC / 24 V AC 110-240 V AC / 100-300 V DC
Supply voltage tolerance DC: -15...+15 % AC: -15...+10 %
Rated frequency 0 Hz or 50/60 Hz
Power consumption 2 W at 24 V DC 4.5 VA at 230 V AC
Indication of operational states
Supply voltage U: green LED
1st / 2nd output relay energized R1: yellow LED / R2: yellow LED
General data
Ambient temperature range operation / storage -20...+60 °C / -40...+80 °C
Temperature coefcient ±300 ppm/°C
Mounting position any
Mounting DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter
Electrical connection
Wire size rigid plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
ne-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
Stripping length 7 mm (0.28 inch)
Tightening torque 0.4 Nm (3.5 ib.in)
Electromagnetic compatibility
Interference immunity EN 61000-6-2
electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
electromagnetic eld (HF radiation resistance) IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)
powerful impulses (Surge) IEC/EN 61000-4-5 ±2 kV / ±1 kV
HF line emission IEC/EN 61000-4-6 10 V
Interference emission EN 61000-6-4 Class B
Isolation data
Insulation voltage (between all isolated circuits) 2.5 kV
Test voltage (between all isolated circuits) 2.5 kV
1) When connecting a 2-wire sensor, the terminals J and H have to be jumpered.
Analog signal converters
Technical data
Signal converters
Low Voltage Products & Systems 12.23
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Type CC-E/I CC-E IAC/ILPO
Input circuits - Analog inputs
J-G-H C-D
AC current DC current 2 meas. ranges selectable
Rated input range 0-5 A / 0-20 A 0-5 A / 0-20 A
0-1 A / 0-5 A / sinusoidal
Measuring frequency 50/60 Hz
Overload capacity of inputs input range 1 10 x INom (50 A) for max. 1 s 10 x INom (50 A) for max. 2 s
input range 2 10 x INom (200 A) for max. 1 s 10 x INom (200 A) for max. 2 s
Gain adjustment range ±5 % (universal devices) -
Offset adjustment range ±5 % (universal devices) -
Input impedance / resistance 5A : 65 mq20 A : 2.5 mq5 mq
Output circuits - Analog outputs D-F
Current
A-C
Voltage
F-E
passive current output in proportion
to input current
Output signal 0-20 mA / 4-20 mA 0-10 V 4-20 mA
Output burden / load
500 q 1.0 q
12 V DC: 150 q,
24 V DC: 750 q
30 V DC: 1050 q
Accuracy 1) ± 2 % of full-scale
Offset adjustment range ±5 % (universal device) ± 5 %
Gain adjustment range ±5 % (universal device) ± 20 %
Residual ripple < 0.5 %
Response time 0.5 s 0.6 s
Transmission frequency DC or 50/60 Hz AC: 50/60 Hz
Reaction to input circuit interruption Low fail safe: output voltage < 200 mA,
output current < 400 µA -
Supply circuits K-M DC versions AC versions
Supply voltage 24 V DC 110-240 V AC
50/60 Hz 12-30 V DC
Supply voltage tolerance -15...+15 % -15...+10 % -
Power consumption typ 1.5 W typ 1.5 VA -
Indication of operational states
Supply voltage U: green LED -
General data
Ambient temperature range operation / storage 0...+60 °C / -20...+80 °C -20...+60 °C / -40...+80 °C
Temperature coefcient ± 500 ppm/°C 300 ppm/°C
Degree of protection (DIN 40050) IP20
Mounting position ventilation slots on top and bottom
Mounting DIN rail (IEC/EN 60715), snap-on mounting
Electrical connection
Wire size rigid 0.2-4 mm² (24-12 AWG)
ne-strand with(out) wire end ferrule 0.2-2.5 mm² (24-14 AWG)
Stripping length 7 mm (0.28 inch)
Tightening torque 0.5 Nm (4.4 lb.in)
Electromagnetic compatibility
Interference immunity EN 61000-6-2
electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
electromagnetic eld (HF radiation resistance) IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)
powerful impulses (Surge) IEC/EN 61000-4-5 ±2 kV / ±1 kV
HF line emission IEC/EN 61000-4-6 10 V
Interference emission EN 61000-6-4 Class B
Isolation data
Test voltage (between all isolated circuits) 2.5 kV AC
Rated insulation voltage - 250 V AC
1) Includes non-linearity and factory setting, inuenced by supply voltage and output load.
Analog signal converters
Technical data
Signal converters
12.24 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Type CC-U/I CC-U/V
Input circuits - Analog inputs J-G-H any current signals,
RMS measurement
any voltage signals
,
RMS measurement
Rated input range 0-1 A
0-5 A
0-100 V, 0-200 V
0-300 V, 0-400 V
0-500 V, 0-600 V
Measuring frequency 0-600 Hz
Overload capacity of inputs input range 1 10 x INom (10 A) for max. 2 s -
input range 2 10 x INom (50 A) for max. 2 s -
Gain adjustment range ±15 %
Offset adjustment range ±20 %
Input impedance / resistance 1A: 60 mq,
5 A: 12 mq> 800 kq
Output circuits - Analog outputs D-F, A-C Current Voltage
Output signal 0-20 mA, 4-20 mA
0-5 V, 1-5 V, 0-10 V, 2-10 V, ± 10 V
Output load 600 q 4.7 Kq
Accuracy1) ±0.5 % of full-scale
Temperature coefcient ±250 ppm/°C max. ±300 ppm/°C max.
Residual ripple < 0.15 %
Response time 150 ms
Supply circuits K-M
Rated supply voltage 24-48 V DC 110-240 V AC
Supply voltage range 24-48 V DC, 24 V AC 110-240 V AC, 100-300 V DC
Supply voltage tolerance DC: -15...+15 % AC: -15...+10 %
Rated frequency 0 Hz or 50/60 Hz
Power consumption 2 W at 24 V DC 4.5 VA at 230 V AC
Indication of operational states
Supply voltage U: green LED
General data
Ambient temperature range operation / storage -20...+60 °C / -40...+80 °C
Mounting position any
Mounting DIN rail (IEC/EN 60715), snap-on mounting / screw mounting with adapter
Electrical connection
Wire size rigid plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
ne-strand with(out) wire end ferrule plug-connector with screw terminals 0.2-2.5 mm2 (24-12 AWG)
Stripping length 7 mm (0.28 inch)
Tightening torque 0.4 Nm (3.5 lb.in)
Standards
Product standard -
Low Voltage directive 2006/95/EG
EMC directive 2004/108/EG
RoHS directive 2002/95/EG
Electromagnetic compatibility
Interference immunity EN 61000-6-2
electrostatic discharge (ESD) IEC/EN 61000-4-2 Level 3 (±6 kV / ±8 kV)
electromagnetic eld (HF radiation resistance) IEC/EN 61000-4-3 10 V/m
fast transients (Burst) IEC/EN 61000-4-4 Level 3 (±2 kV / 5 kH)
powerful impulses (Surge) IEC/EN 61000-4-5 ±2 kV / ±1 kV
HF line emission IEC/EN 61000-4-6 10 V
Interference emission EN 61000-6-4 Class B
Isolation data
Insulation voltage (between all isolated circuits) 1.5 kV
Test voltage (between all isolated circuits) 1.5 kV / 50 Hz
1) Includes non-linearity and factory setting, inuenced by supply voltage and output load.
Analog signal converters
Technical data
Signal converters
Low Voltage Products & Systems 12.25
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
.039
J
DF
G
M
H
LK
AC
E
B
CC-E/x CC-E IAC/ILPO, CC-E I/I
CC-U/x , CC-U/xR
22.5
0,88 " 18
0.71"
1.0
0.9
0.8
0.7
0.6
0.5
F
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
cos
Dimensional drawings Dimensions in mm and inches
Connection diagram CC-U/x
Width 22.5 mm (0.89 in)
Technical diagrams
Load limit curves CC-U/xxR
Resistive AC load Resistive DC load
Derating curve
Analog signal converters
Technical diagrams, connection diagrams
Approximate dimensions
Signal converters
12.26 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Notes
Signal converters
Low Voltage Products & Systems 12.27
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Serial data converters
Serial data
Converters
In the eld of industrial data transmission, various processes of data transmission and interfaces are
used today. Already existing systems need to
be updated or connected to new devices for continuity of process. When new communication func-
tions are not build-in, ABB propose a range of
converters to be able to use from the standard RS232 or RS485, to the Ethernet open products or the
Optical Fiber.
Ethernet communication is now one of the main features need in open communication, ABB propose
the e-ILPH to connect the serial devices to
the web world.
Signal converters
12.28 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
RS-232 RS-485
RS-232 RS-232
RS-422
RS-422 RS-422
RS-422
RS-232
RS-232 RS-232 RS-232 RS-232
RS-232 RS-232
15 m
max.
1.2 km
max.
15 m
max.
1.2 km
max.
TCP RS-232
RS-485
Modbus / RTUModbus / TCP
Uses
Adaptation
The use of converters allows the connection of two devices using different
interfaces.
To add new equipment to existing installations.
Galvanic Isolation
To protect sensitive equipment it is sometimes necessary to use converters which
allow galvanic isolation.
Type of connection Immunity to noise
RS232 Low
RS422 High
RS485 High
CL High
OF Very high
Ethernet High
To cross a disturbed environment
Some interfaces are more sensitive to noise. Electrically, it is preferable, in
some cases, to change the interface or support.
Multipoint connections
Some equipment is only designed to communicate in RS232 point to point connec-
tion. To communicate with several devices it is then necessary to use converters
RS232 to RS422, RS485, CL or OF to reach multipoint mode.
Type of connection Connection
RS232 Point to point
RS422 12 points
RS485 32 points
CL 5-6 points
OF 32 points
Ethernet Point to point or multipoint
Type of connection Max. distances *
RS232 15m
RS422 1.2km
RS485 1.2km
CL 300-500m
OF 4km
Ethernet 100 m with CAT5 cable
Increase in the transmission and amplification
distances of the signals
Every connection has its own limits, to increase the communication distances you
only have to change the type of link (converter) or amplify the signal
(Repeater) using an ILPH.
* Depending on transmission speed.
Example :
Example :
Line 1
Line 2
Power
Converter Repeater
Example :
Example :
Example :
Noisy
elements
RS-485 2-/4 wires
"World Wide" communication
Communication is more and more used with Ethernet support. The interests are to
have a distant access, to use an already existing network and to upload information
and data on a supervisor or a computer. The conversions from
serial to Ethernet protocol are used to connect local network to Ethernet.
Protocol conversion
Modbus is one of the main protocols used in the industrial networks. The
creation of Modbus/TCP allows an adapted access to the Ethernet network. So, the
conversion between these 2 protocols is necessary.
Example :
Example :
Serial data converters
Overview
Signal converters
Low Voltage Products & Systems 12.29
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
1SNA684234R2000
1SNA684244R0200
1SNA684231R2500
1SNA684233R2700
1SNA684333R2300
1SNA684334R2400
1SNA684202R0100
1SNA684236R2200
1SNA684237R2300
1SNA684238R0400
1SNA684239R0500
1SNA684212R2200
1SNA684232R2600
1SNA684246R0400
1SNA684247R0500
1SNA684248R1600
1SNA684249R1700
1SNA684252R0200
RS232
RS422 /RS485
RS485
RS232 / RS485
RS232
RS422 / RS485
24 V DC
24-48 V DC
110-240 V AC
24-42 V AC/DC
Ethernet
10-34 VDC, 10-24 VAC
RS 232 - EIA-232 / V.24 / V.28
Point-to-point connection
Max. 15 m transmission distance
Rate up to 19.2 kbit/s
Full-duplex
RS 422 - EIA-422 / V.11
Point-to-point connection
(1 Transmitter - 10 Receivers)
Differential voltage transmission
Full-duplex
Up to 1200 m/ 10Mbit/s
Good EMC characteristics
Current loop(TTY)
Point-to-point / multi-point connection
Active or passive current loop
Full-duplex
Up to 1200 m/19.2 kBit/s
Good EMC characteristics
RS 485 - ISO/IEC/EIA-485
Multi-point connection up to 32 units
Differential voltage transmission
Half-duplex on 1 pair
Full-duplex on 2 pairs
Up to 1200 m / 10Mbit/s
Good EMC characteristics
Optical fiber interface
Point-to-point connection
Full-duplex
From 40m up to 4km transmission distance
according to optical ber material (plastic / glass)
and wavelength used up to 10 Mbit/s
Excellent EMC characteristics
Ethernet Interface
Point to point connexion or multipoint connection.
Up to 100m using CAT5 cable without Hub or Switch
10/100 Mbit/s
Good EMC characteristics
In-Ps-Out
In-Ps-Out
Wi
In-Out
In-Ps-Out
In-Ps-Out
In-Out
In-Ps-Out
In-Ps-Out
In-Ps-Out
In-Ps-Out
In-Out
In-Out
In-Ps-Out
In-Ps-Out
In-Ps-Out
In-Ps-Out
In-Ps-Out
Insulation *
Catalog number
* In=Input, Ps=Power supply, Out=Output, Wi=Without insulation
CL
OF-S
OF-P
Serial data converters
Selection table
Signal converters
12.30 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
ILPH RS 232 - 485 / Ethernet
Isolated RS232 or/and RS485 to Ethernet converter
• Triple galvanic isolation
• RS232 on SUBD 9 points or screw connectors
• RS485 on removable screw connectors
• Ethernet 10/100 Mbit/s, RJ45 connector
• Power supply 10-34 VDC et 10-24 VAC
• Possible to have a redundant 10-34 VDC power supply
• Economic with low consumption
• Up to 100m with CAT5 cable without Hub or Switch
• Good EMC characteristics
• Up to 2 Modbus®\TCP Masters
Available modes:
• Modbus®\TCP to Modbus® RTU conversion
• Transparent Client or Server mode
• SMTP mode (Mail send)
Standards: TPC/IP, TELNET, DHCP, FTP
• Specics functions in Modbus® protocol:
• Concentrator (Asynchronous mode) up to 1200 words
• AC31 programming
Modbus® Easy Net mode : this mode could be used to exchange data without a Modbus®/TCP
master. The data are logged in a table and could be distributed to one or all the others e-ILPH
participants on Ethernet.
ILPH RS 232 / RS 422 - 485
RS 232 to RS 422-485 serial link without isolation
• Economic version without isolation
• Baudrate up to 38.4 kbit/s
• Transmission distance up to 1200 m
• RS 485 1 or 2 pair handling
• Usable in "noisy" environments
• 24 V DC power supply
• CE mark
ILPH RS 232 / RS 422 - 485
Galvanic isolated converter for RS 232 to RS 422-485 serial links.
• Galvanic isolation between input/output and output/power supply
• Baudrate up to 38.4 kbit/s
• Transmission distance up to 1200 m
• RS 485 1 or 2 pair handling
• Usable in "noisy" environments
• 24 V DC power supply
• CE mark
ILPH RS 232 / RS 422 - 485
3 way galvanic isolated converter for RS 232 to RS 422-485 serial links.
• 3 way galvanic isolation between power supply and input/output
• RS 485 switch on 2 or 4 wires
• Baudrate up to 38.4 kbit/s
• Transmission distance up to 1200 m
• RS 485 1 or 2 pair handling
• Usable in "noisy" environments
• 24...48 V DC and 115...230 V AC power supply
• CE marking
ILPH RS 232 / RS 232
3 way galvanic isolator between RS 232 serial interface and another
RS 232 serial interface.
• Ensures triple insulation between the 2 serial interfaces and between each and
power supply
• Baudrate up to 19.2 kbit/s (up to 64 kbit/s depending on cable)
• Transmission distance up to 15 m
• Can be used in "noisy" environments
• Power supply from 24...48 V DC and 115...230 V AC CE marking
ILPH RS 422 - 485 / RS 422 - 485
Galvanic isolated connection between an RS 422-485 (1 or 2 pairs) and an RS 422
485 (1 or 2 pairs) serial link. It amplies the signal beyond the 1200 m limit distance of
the RS 422-485 and only needs a minimum of 1.5 character delay time to switch off
the RS 485 drivers.
Galvanic isolation between power supply/output and input/output
• Baudrate up to 500 kbit/s (up to 200 m)
• Transmission distance up to 1200m at 38.4 kbit/s
• Usable in "noisy" environments
• 2/4 wires automatic handling
• 24 V DC power supply
• CE mark
ILPH RS 232 / FO
• 3 way galvanic isolated Converter for RS 232 to optical ber serial link glass (S) or
plastic (P).
• 3 way galvanic isolation between power supply and input/output
• Baud rate up to 115.2 kbit/s
• Available for glass or plastic ber
• Transmission distance up to 4 km
• Usable in "very noisy" environments
• 20...42 V AC/DC and 110...240 V AC/DC power supply
• CE marked
ILPH RS 485 / FO
3 way galvanic isolated converter for RS 485 (1 pair) to optical ber serial link glass
(S) or plastic (P).
3 way galvanic isolation between power supply and input/output
• Baud rate up to 1.5 Mbit/s
• Available for glass ber or plastic ber
• Transmission distance up to 4 km
• Usable in "very noisy" environments
20...42 V AC/DC and 110...240 V AC/DC power supply
• CE marked
Galvanic isolated converter for current loop to RS 422-485 (1 or 2
pairs) serial link.
• Galvanic isolation between power supply/current loop and RS 422-485/current loop
• Active/passive 0...20 mA / 4...20 mA selectable
Positive or negative logic selectable
• Baudrate up to 38.4 kbit/s (up to 2400 m)
Transmission distance up to 2400 m (1200 m RS 485 and 1200 m current loop)
• Usable in "noisy" environments
• 24 V DC power supply
• CE marking
ILPH CL / RS 422 - 485
Galvanic isolated Converter for RS 232 to current loop serial link.
• Galvanic isolation between power supply/current loop and RS 232/current loop
• Active/Passive 0...20 mA / 4...20 mA selectable
Positive or negative logic selectable
• Baudrate up to 38.4 kbit/s
• Transmission distance up to 1200 m
• Usable in "noisy" environments
• 24 V DC power supply
• CE marking
ILPH RS 232 / CL
Serial data converters
Benets and advantages
Signal converters
Low Voltage Products & Systems 12.31
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Description
Type Catalog number
Weight
(1 pce)
kg (lb)
Serial data converter e-ILPH ILPH RS 232-RS 485 /
Ethernet 1SNA684252R0200 0.12 (0.265)
Serial link interface without galvanic isolation ILPH RS 232 /
RS 422-485 1SNA684231R2500 0.1 (0.220)
Serial link interface with galvanic isolation ILPH RS 232 /
RS 422-485 1SNA684233R2700 0.1 (0.220)
Serial link interface 3 way galvanic isolation
ILPH RS 232 / RS 422-485
(24-48 V DC
power supply)
1SNA684333R2300
0.1 (0.220)
ILPH RS 232 / RS 422-485
(115-230 V DC
power supply)
1SNA684334R2400
Serial link interface 3 way galvanic isolation
ILPH RS 232 / RS 232 (24-
48 V DC power supply) 1SNA684234R2000
0.1 (0.220)
ILPH RS 232 / RS 232 (115-
230 V DC power supply) 1SNA684234R0200
Serial link interface with galvanic isolation
ILPH RS 422 - 485 / RS
422 - 485 (24 V DC power
supply)
1SNA684212R2200 0.1 (0.220)
Serial link interface 3 way galvanic isolation
ILPH RS 232 / FO-S (24...42
V AC/DC power supply) 1SNA684236R2200
0.15 (0.331)
ILPH RS 232 / FO-S
(110...240 V AC/DC power
supply)
1SNA684237R2300
ILPH RS 232 / FO-P (24...42
V AC/DC power supply) 1SNA684238R0400
ILPH RS 232 / FO-P
(110...240 V AC/DC power
supply)
1SNA684239R0500
Serial link interface 3 way galvanic isolation
ILPH RS 485 / FO-S (24...42
V AC/DC power supply) 1SNA684246R0400
0.15 (0.331)
ILPH RS 485 / FO-S
(110...240 V AC/DC power
supply)
1SNA684247R0500
ILPH RS 485 / FO-P (24...42
V AC/DC power supply) 1SNA684248R1600
ILPH RS 485 / FO-P
(110...240 V AC/DC power
supply)
1SNA684249R1700
Serial link interface with galvanic isoaltion ILPH BdC /RS 422 - 485
(24 V DC power supply) 1SNA684232R2600 0.1 (0.220)
Serial link interface with galvanic isolation ILPH RS 232 BdC
(24 V DC power supply) 1SNA684202R0100 0.1 (0.220)
Serial data converters
Ordering details
Signal converters
12.32 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
center of rail
ILPH RS 232 - 485 Ethernet
ILPH RS 232 / RS 232
ILPH RS 232 / FO
ILPH RS 232 - 485 Ethernet
(without isolation)
ILPH RS 232 - 485 Ethernet
(isolated)
R
Rt E
center of rail
Conguration of
the jumper
R
E
R
E
RS 485 LINK ON ONE PAIR
R ON/OFF Jumper R in position R ON/OFF
E ON/OFF Jumper E in position E ON/OFF
The Receiver and the Transmitter are activated alternately
(never at the same time) depending on the status of the CTRL
IN signal.
CTRL IN STATUS ACTION ON RS 485
0 logic (+3V ≤ U ≤ +25V) Transmitter active / Receiver inactive
1 logic (-25V ≤ U ≤ -3V) Transmitter inactive /Receiver active
High impedance Transmitter inactive /Receiver active
NOTE : For RS 232 products running the RTS ( REQUEST TO SEND) signal,
connect RTS to CTRL IN. Otherwise, connect M (RxD ILPH) to L (CTRL IN).
RS 485 LINK ON 2 PAIRS
R ON Jumper R in position R ON
E ON/OFF Jumper E in position E ON/OFF
Receiver permanently active
Transmitter controlled by the signal CTRL IN (see table for
Transmitter operation as a function of CTRL IN)
RS 422 LINK ON TWO PAIRS
R ON Jumper R in position R ON
E ON Jumper E in position E ON
The Transmitter and Receiver are both permanently active.
POLARIZATION OF THE RS 422 - RS 485 LINE
The line must always be polarized.
The ILPH is used to polarize the reception channel :
Connection by 1 wire P+ (J1.1) with 5V (J1.4)
Connection by 1 wire P- (J1.2) with 0V (J1.3)
ADAPTING THE RS 422 - RS 485 LINE
The line must always be adapted to the level of t
he reception channel of each subscriber forming the end of the
bus. The ILPH is used to adapt the reception channel by setting
the jumper Rt correctly :
* Line adaptation, Rt = 120 ( general case )
* Line adaptation, Rt = 220
* No line adaptation, Rt =
Rt
Rt
Rt
R
E
R
E
R
E
R
E
Rt
Rt
Rt
RS 485 LINK ON ONE PAIR
R ON/OFF Jumper R in position R ON/OFF
E ON/OFF Jumper E in position E ON/OFF
The Receiver and the Transmitter are activated alternately (never
at the same time) depending on the status of the CTRL IN
signal.
CTRL IN STATUS ACTION ON RS 485
0 logic (+3V U +25V) Transmitter active / Receiver inactive
1 logic (-25V U -3V) Transmitter inactive / Receiver active
High impedance Transmitter inactive / Receiver active
CAUTION : For RS 232 products running the RTS ( REQUEST TO SEND)
signal, connect RTS to CTRL IN. Otherwise, connect M (RxD ILPH) to L
(CTRL IN).
RS 485 LINK ON 2 PAIRS
R ON Jumper R in position R ON
E ON/OFF Jumper E in position E ON/OFF
Receiver permanently active
Transmitter controlled by the signal CTRL IN ( see table for
Transmitter operation as a function of CTRL IN )
RS 422 LINK ON TWO PAIRS
R ON Jumper R in position R ON
E ON Jumper E in position E ON
The Transmitter and Receiver are both permanently active.
POLARIZATION OF THE RS 422 - RS 485 LINE
The line must always be polarized. The ILPH is used to polarize
the reception channel :
Connection by 1 wire P+ (J1.1) with 5V (J1.4)
Connection by 1 wire P- (J1.2) with 0V (J1.3)
ADAPTING THE RS 422 - RS 485 LINE
The line must always be adapted to the level of the reception
channel of each subscriber forming the end of the bus.
The ILPH is used to adapt the reception channel by setting the
jumper Rt correctly :
* Line adaptation, Rt = 120 ( general case )
* Line adaptation, Rt = 220
* No line adaptation, Rt =
R
Rt
E
Conguration of
the jumpers
center of rail
center of rail
Serial data converters
Jumper
Approximate dimensions
Signal converters
Low Voltage Products & Systems 12.33
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
ILPH RS 232 / CL
ILPH RS 485 / FO
ILPH CL / RS 422 - 485
Galvanic isolated converter
for current loop
CONFIGURATION
The various congurations can be selected using the 4 micro-switches located
inside the box.
OPERATING MODE ACTIVE OR PASSIVE
The Current Loop's Transmission and Reception can be independently in active or
passive mode.
Select operating mode using S1 and S2.
S1
Transmission(TxD) ON = Active / OFF = Passive
S2
Reception (RxD) ON = Active / OFF = Passive
SIGNAL LEVEL
Select signal level 4-20 mA or 0-20 mA.
This selection is made using micro-switch S3
S3 ON = 4-20 mA / OFF = 0-20 mA
Caution :
It is not possible to select a 4-20 mA signal when the
Reception is in active mode.
LOGIC LEVEL
Conguration : Positive logic (0 Logic = 20 mA)
or negative logic (1 Logic = 20 mA)
using micro-switch S4
S4 ON = (1 = 20 mA) / OFF = (0 = 20 mA)
ON
OFF
S1 S2 S3 S4
ON
OFF
S1 S2 S3 S4
INT4
S1 S2 S3 S4
ON
OFF
INT4
LINE AMPLIFIER CONFIGURATION
Conguration of ampliers of the RS 422 - RS 485 (Receiver, Transmitter) line pro-
vides greater exibility of use.
The various congurations can be selected using the 2 jumpers
(R INT2, E INT1) located inside the box.
RS 485 LINK ON ONE PAIR
The Receiver and the Transmitter are activated alternately (never at the same time)
depending on the status of the Current Loop Reception signal.
RS 485 LINK ON TWO PAIRS
Receiver permanently active. Transmitter controlled by the Current Loop Reception
signal.
RS 422 LINK ON TWO PAIRS
The Receiver and the Transmitter are both permanently active.
POLARIZATION OF THE RS 422 - RS 485 LINE
The line must always be polarized. The ILPH is used to polarize the reception channel :
Connection by 1 wire P+ (J1.1) with 5 Viso (J1.4)
Connection by 1 wire P- (J1.2) with 0 Viso (J1.3)
ADAPTING THE RS 422 - RS 485 LINE
The line must always be adapted to the level of the reception channel of each sub-
scriber forming the end of the bus. The ILPH is used to adapt the reception channel
by setting the jumper Rt correctly :
POLARIZATION
The polarization can be congured using the INT4 jumper.
Protection ON
Protection OFF, used if power supply at
minimum value (21.6 V).
E
R
E ON/OFF Jumper E in position E ON/OFF
R ON/OFF Jumper R in position R ON/OFF
E
INT2 R ON
INT3 E
ON / OFF
RR ON Jumper R in position R ON
E ON/OFF Jumper E in position E ON/OFF
E
INT2 R ON
INT3 E ON
R ON Jumper R in position R ON
E ON Jumper E in position E ON
Rt
Rt INT1
* Line adaptation, Rt = 120 (Standard)
* No line adaptation, Rt =
Transmission (TxD) active
Transmission(TxD) passive
Reception (RxD) active
Reception (RxD) passive
4...20 mA Signal
0...20 mA Signal
Signal logic 1 = 20 mA
Signal logic 0 = 20 mA
on
off
Legend
INT1 INT2 INT3
Rt E R
INT4
Conguration of
the jumper
Polarization
center of rail
Serial data converters
Jumper, micro-switch
Approximate dimensions
Conguration of
the micro-switches
center of rail
S1 S2 S3 S4
ON
OFF
S1 S2 S3 S4
INT1
INT2
INT3
Signal converters
12.34 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
ILPH RS 232 - 485 Ethernet
(3 way galvanic isolated)
ILPH RS 422 - 485 / RS 422 / - 485
Conguration
of the jumper
center of rail
RS 485 LINK ON ONE PAIR
Set SW1-1, SW1-3, SW1-6, SW1-7 and SW1-8 to
position ON.
The receiver and the transmitter are activated alternate-
ly (never at the same time), depending on the status of
the CTRL IN signal.
CTRL IN STATUS Action on RS 485
0 Logic (3V U + 25V) Transmitter active /
Receiver inactive
1 Logic (-25V U -3V) Transmitter inactive /
Receiver active
High impedance Transmitter inactive /
Receiver active
CAUTION : For RS 232 products running the RTS
signal (REQUEST TO SEND), connect RTS to CTRL IN.
Otherwise, set SW2-1 to position ON.
RS 485 LINK ON TWO PAIRS
Set SW1-1, SW1-3, SW1-7 in position OFF.
Set SW1-6, SW1-8 in position ON.
The receiver is permanently active.
The transmitter is controlled by the signal CTRL IN
(see table for transmitter operation as a fonction of
CTRL IN).
RS 422 LINK ON TWO PAIRS
Set SW1-1, SW1-3, SW1-7 and SW1-8 in position
OFF.
Set SW1-6 in position ON.
Transmitter and receiver are both permanently active.
POLARIZATION OF THE RS 422 - RS 485 LINE
The ILPH is used to polarize the reception channel :
Set SW1-4 and SW1-5 in position ON.
ADAPTING THE RS 422 - RS 485 LINE
The line must always be adapted to the level of the
reception channel of each subscriber forming the end
of the bus.
The ILPH is used to adapt the reception channel by
setting the jumper SW1-2 correctly :
SW1-2 in position ON line adaptation, Rt = 120
(standard)
SW1-2 in position OFF no line adaptation, Rt =
OFF
INT 1
1 2 3 4 1 2 3 4
INT 2
OFF
OFF
INT 4
1 2 3 4 5 6
OFF
INT 3
1 2 3 4
center of rail
Channel 1
Conguration of
the micro-switch
Channel 2
Conguration of
the micro-switch
Baud rate
Conguration
of the micro-switch
INT 1
1 2 3 4
0 0 0 0
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 0
1 1 0 0
1 0 0 0
0 0 0 0
INT 2
1 2 3 4
0 0 0 0
1 1 1 1
1 1 1 0
1 1 0 0
1 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
INT 3
1 2 3 4
X X X 1
X X X 0
X X X 0
X X X 0
X X X 0
X X X 0
X X X 0
X X X 0
X X X 0
X X X 0
INT 4
1 2 3 4 5 6
X X X 1 0 1
X X X 0 0 0
X X X 0 0 0
X X X 0 0 0
X X X 0 0 0
X X X 0 0 0
X X X 0 0 0
X X X 0 0 0
X X X 0 0 0
X X X 0 0 0
Nu = not used
X = zero
1 = contact closed
0 = contact open (aus) (off)
BAUD RATE
FULL DUPLEX
500 Kb/s
187.5 Kb/s
93.75 Kb/s
38.4 Kb/s
19.2 Kb/s
9.6 Kb/s
4.8 Kb/s
2.4 Kb/s
1.2 Kb/s
OFF
1 2 3 4
INT 3
INT 4
INT 3.1
INT 3.2
INT 4.1
INT 4.2
"ON", polarizes the reception
channel Rx2
"ON", polarizes the reception
channel Rx1
RS 422 - RS 485 DRIVERS CONTROL
The RS 422 - RS 485 Drivers Control (transmitters and
receivers) makes the ILPH easy to use. The control of
the 2 channels is completely automatic ; you only have
to congure the baud rate needed.
The minimum turn off delay is about 1.5 character/
time from 27 µs to 10 ms depending on the baud rate
selected.
POLARIZATION OF THE RS 422 - RS 485 CONNEC-
TIONS
The connections must always be polarized. The ILPH is
used to polarize the reception channels :
ADAPTING THE RS 422 - RS 485 CONNECTIONS
The connections must always be adjusted to the level
of the reception channel of each subscriber forming
the end of the bus. The ILPH is used to adjust the
reception channel by setting the micro-switch INT 3.3
and INT 4.3.
BAUD RATE
By using the 8 micro-switches inside the box.
Permits to dene up to 8 transmission speeds and to
select the Full
Duplex operation mode (RS 422 / RS 422) in addition
with the INT 3.4 INT 4.4 and INT 4.5 micro switches.
INT 3.3 and INT
4.3 "ON" 120
set adjustment
Serial data converters
Jumper, micro-switch
Approximate dimensions
OFF
1 2 3 4 5 6
INT 1 INT 2
1 2 3 4 1 2 3 4
OFF OFF
INT 3 INT 4
1 2 3 4 5 6
1 2 3 4
OFF OFF
Signal converters
Low Voltage Products & Systems 12.35
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 - 485 / Ethernet
Power supply 1
Voltage 10...34 V DC, 10...24 V AC
Voltage tolerance -10%, +10%
Consumption 2 W max
Connections coding screw removable connector 0 to 2.5 mm² (22-14 AWG)
Power supply 2
Voltage 10...34 V DC
Voltage tolerance -10%, +10%
Consumption 2 W max
Connections screw connector (AWG 20)
Serial link 1: RS 232 EIA RS 232
Overvoltage protection integrated
Baud rate / Transmission distance max. 115.2 kbits/s / max. 15 m
Connections 2.5 mm² screw connector (AWG 20) or male SubD 9 points
Serial link 2: RS 485 EIA RS 485
Voltage integrated
Line polarization integrated
End line resistance integrated
Baud rate / Transmission distance max. 115.2 kbits/s / max. 1200 m
Connections coding screw removable connector 0 to 2.5 mm² (22-14 AWG)
Ethernet link
Overvoltage protection integrated
Baud rate / Transmission distance 10-100 Mbits/s / max. 100 m without Hub or Switch with CAT5 cable
Connections RJ45 connector
Traffic indication
Voltage 1 yellow LED
Status of signal 3 green LED (RxD, TxD, LINK), 2 amber or green LED (Speed, Activity)
EMC behavior
Electrostatic discharge EN 61000-4-2
Radiated electromagnetic eld EN 61000-4-3
Burst EN 61000-4-4
Surge EN 61000-4-5
Electromagnetic compatibility EN 55022
Other characteristics
Galvanic isolation between serial link / power supply / Ethernet link 750 VDC / 1500 VAC
Conguration of the operating mode using internal switches or/and software (TELNET or HYPERTERMINAL)
Operating temperature 0°C ... +60°C
Storage temperature -20°C ... +70°C
Mounting any required
DIN rail xing (EN 50002) snap-on mounting
Wire size 2.5 mm² / stranded with ferrule, 4 mm² solid
Dimensions (WxDxH) 94 x 22.5 x 100 mm
Weight 120 g
+24V
0V
24V
TXTX
GND
RXRX
B1+
B2-
M
JHG
M
L
K
D
E
A
GNDRX TX
Ethernet
LINK
TXD
RXD
e-ILPH
SPEED
PWR
ACTIVITY
M
L
K
JHG
M
L
K
4
3
2
1
ON
4
3
2
1
ON
5678
K
L
DEA
SubD9
connector
pin 2 = RX
pin 3 = TX
pin 5 = GND
pin 7 = RTS
Serial data converters
Technical data
Signal converters
12.36 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / RS 422 - 485 (without isolation)
Power supply polarized
Voltage 24 V DC
Voltage tolerance 8.5...28 V DC
Supply current 100 mA max
Connections removable screw connectors (AWG 20)
Serial link 1: RS 232 EIA RS 232 C / CCITT V24 V28
Overvoltage protection integrated (transil 8 kV 1.2/50 µs)
Baud rate / Transmission distance max. 38.4 kbits/s / max. 1200 m
Connections 2.5 mm² screw connectors (AWG 20)
Serial link 2: RS 422-485 EIA RS 485 and EIA RS 422 / CCITT V11
Overvoltage protection integrated (transil 8 kV 1.2/50 µs)
Baud rate / Transmission distance max. 38.4 kbits / max. 1200 m
Connections 2.5 mm² screw connectors (AWG 20)
Traffic indication
Voltage 1 yellow LED
Connections 2 green LED (RxD, TxD)
EMC behavior
Electrostatic discharge EN 61000-4-2 level 3 6/8 kV
Radiated electromagnetic eld EN 61000-4-3 level 310 V/m
Burst EN 61000-4-4 level 3 1 kV
Electromagnetic compatibility EN 55022 class B
Other characteristics
Galvanic isolation between serial link / power supply / Ethernet link no
Conguration of the operating mode using internal jumper
Operating temperature 0°C ... +50°C
Storage temperature -25°C ... +80°C
Mounting any required
DIN rail xing (EN 50002) snap-on mounting
Wire size 2.5 mm² / stranded with ferrule, 4 mm² solid
Dimensions (WxDxH) 88 x 22.5 x 100 mm
Weight 100 g
*CAUTION :
When the RTS Signal is not activated,
M terminal (RxD ILPH) has to be con-
nected to L terminal (CTRL IN).
RS 422 - RS 485
SERIAL LINK (2 wires)
Product RS 232
Connector J1
24 V DC
power supply
Product RS 422-RS 485 ** CAUTION :
To be connected to 2 wired RS 485 only (not pos-
sible for 4 wired RS 422).
When the RTS Signal is not activated, M terminal
(RxD ILPH) has to be connected to L terminal
(CTRL IN).
RS 422 - RS 485
SERIAL LINK (4 wires)
Product RS 232
Connector J1
24 V DC
power supply
Product RS 422-RS 485
Serial data converters
Technical data
Signal converters
Low Voltage Products & Systems 12.37
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / RS 422 - 485 (isolated)
Power supply polarized
Voltage 24 V DC
Voltage tolerance 8.5...28 V DC
Supply current 100 mA max
Connections Removable screw connectors (Omniconnect)
Serial link 1: RS 232 EIA RS 232 C / CCITT V24 V28
Overvoltage protection integrated (transil 8 kV 1.2/50µs)
Baud rate / Transmission distance max. 38.4 kbits/s / max. 15 m
Connections 2.5 mm² screw connectors (AWG 20)
Serial link 2: RS 422-485 EIA RS 485 and EIA RS 422 / CCITT V11
Overvoltage protection integrated (transil 8 kV 1.2/50 µs)
Baud rate / Transmission distance max. 38.4 kbits / max. 1200 m
Connections 2.5 mm² screw connectors (AWG 20)
Traffic indication
Voltage 1 yellow LED
Connections 3 green LED (RxD, TxD and CTRL-IN)
EMC behavior
Electrostatic discharge EN 61000-4-2 level 3 6/8 kV
Radiated electromagnetic eld EN 61000-4-3 level 310 V/m
Burst EN 61000-4-4 level 3 1 kV
Electromagnetic compatibility EN 55022 class B
Other characteristics
Galvanic isolation between serial link / power supply / Ethernet link 500 V DC
Conguration of the operating mode using internal jumper
Operating temperature 0°C ... +50°C
Storage temperature -25°C ... +80°C
Mounting any required
DIN rail xing (EN 50002) snap-on mounting
Wire size 2.5 mm² / stranded with ferrule, 4 mm² solid
Dimensions (WxDxH) 88 x 22.5 x 100 mm
Weight 100 g
** CAUTION :
Only to be connected for RS 485 two pairs
(of no use for RS 422 two pairs). If the RTS
signal is not generated, connect M (RxD
ILPH) to L (CTRL IN).
* CAUTION :
If the RTS signal is not generated,
connect M (RxD ILPH) to L (CTRL IN).
RS 422 - RS 485
2 WIRE SERIAL LINKS
RS 422 - RS 485
4 WIRE SERIAL LINKS
Connector J1
24 V DC
power supply
RS 422-RS
485 product
RS 232 product
Connector J1
24 V DC
power supply
RS 422-RS
485 product
RS 232 product
Serial data converters
Technical data
Signal converters
12.38 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / RS 422 - 485 (3 way galvanic isolated)
Power supply Polarization for DC model
Voltage 24...48 V DC 115...230 V AC (50/60 Hz)
Voltage tolerance -15% ... +20% -15% ... +15%
Supply current 24 V DC<110 mA, 48 V DC<55 mA, 115 V AC<40 mA, 230 V DC<26 mA
Supply power ~ 3 W ~ 3 VA
Connections Removable screw connector (Omniconnect)
Serial link 1: RS 232 EA / TIA RS 232 new revision / CCITT V24 V28
Overvoltage protection integrated (transil 8 kV 1.2/50 μs)
Baud rate / Transmission distance max. 19,2 kbits/s / max. 15 m / 2500 pF
Connections 2.5 mm² screw (AWG 20)
Serial link 2: RS 422-485 EIA / TIA RS 232 new revision / CCITT V24 V28
Overvoltage protection integrated (transil 8 kV 1.2/50μs)
Baud rate / Transmission distance max. 19.2 kbits/s / max. 15 m
Connections 2.5 mm² screw (AWG 20)
Traffic indication
Voltage 1 yellow LED
Connections 4 green LED (RxD, RxC/D, TxD, TxC/D)
EMC behavior
Electrostatic discharge EN 61000-4-2 level 3 6/8 kV
Radiated electromagnetic eld EN 61000-4-3 level 3 10 V/m
Burst EN 61000-4-4 level 3 1 kV
Electromagnetic compatibility EN 55022 class B
Other characteristics
Galvanic isolation between RS 232 / Power supply / RSS 422-RS 485
1,5 kV
Conguration of the operating mode No
Operating temperature 0°C ... +50°C
Storage temperature -25°C ... +80°C
Mounting any required
DIN rail xing (EN 50002) snap-on mounting
Wire size 2.5 mm² / stranded with ferrule, 4 mm² solid
Dimensions (WxDxH) 88 x 22,5 x 100 mm
Weight 100 g
RS 422 - RS 485
2 WIRE SERIAL LINK
**CAUTION :
Only to be connected for RS 485 two
pairs (of no use for RS 422 two pairs).
If the RTS signal is not generated, set
SW2-1 in position ON.
*CAUTION :
When the RTS signal is not generated,
set SW2-1 in position ON.
RS 422 - RS 485
4 WIRE SERIAL LINKS
Product RS 232
Connector J1
Power
supply
Product
RS 422 - RS 485
Product RS 232
Connector J1
Power
supply
Product
RS 422 - RS 485
Serial data converters
Technical data
Signal converters
Low Voltage Products & Systems 12.39
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / RS 232
Power supply DC model polarized
Voltage 24...48 V DC 115...230 V AC (50/60Hz)
Voltage tolerance -15%...+20% -15%...+15%
Supply current
24 V DC<155 mA;48 V DC<77 mA;110 V AC<40 mA;230 V DC<26 mA
Supply power ~ 3.15 W ~ 3.15 VA
Connections Removable screw connector (Omniconnect)
Interface 1: RS 232 EIA / TIA RS 232 new revision / CCITT V24 V28
Overvoltage protection integrated (transil 8 kV 1.2/50 µs)
Transmission capacity / Transmission distance max. 19.2 kbits/s / max. 15 m / 2500 pF
Connections 2.5 mm² screw (AWG 20)
Interface 2: RS 232 EIA / TIA RS 232 new revision / CCITT V24 V28
Overvoltage protection integrated (transil 8 kV 1.2/50 µs)
Transmission capacity / Transmission distance max. 19.2 kbits/s / max. 15 m
Connections 2.5 mm² screw (AWG 20)
Traffic indication
Voltage 1 yellow LED
Connections 4 green LED (RxD, RxC/D, TxD, TxC/D)
EMC behavior
Electrostatic discharge EN 61000-4-2 level 3 6/8 kV
Radiated electromagnetic eld EN 61000-4-3 level 3 10 V/m
Burst EN 61000-4-4 level 3 1 kV
Electromagnetic compatibility EN 55022 class B
Other characteristics
Galvanic isolation between serial link / power supply / Ethernet link 1.5 kV
Conguration of the operating mode No
Operating temperature 0°C ... +50°C
Storage temperature -25°C ... +80°C
Mounting any required
DIN rail xing (EN 50002) snap-on mounting
Wire size 2.5 mm² / stranded with ferrule, 4 mm² solid
Dimensions (WxDxH) 88 x 22.5 x 100 mm
Weight 100 g
Connection
not advised according to
EIA/TIA 232E
standard
or
Connection
not advised
according to
EIA/TIA 232E
standard
(to be connected)
Terminal equipment
for ETTD (DTE) data
processing
Data transmission
end equipment
ETCD (DCE)
Serial data converters
Technical data
Signal converters
12.40 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 422 - 485 / RS 422 - 485
Power supply DC model polarized
Voltage 24 V DC
Voltage tolerance +/-15%
Supply current 120 mA max.
Connections Removable screw connector (Omniconnect)
Interface 1: RS 422-485 EIA / RS 485 and EIA RS 422 / CCITT V11
Overvoltage protection integrated (transil 8 kV 1.2/50 µs)
RS 485 data switching Time switching / Time delay transmission/reception 27 µs ...10 ms
Baud rate / Transmission distance from 1.2 to 500 kbits/s / max. 1200 m up to 38.4 kbit/s
Connections 2.5 mm² screw (AWG 20)
Interface 2: RS 422-485 EIA / RS 485 and EIA RS 422 / CCITT V11
Overvoltage protection integrated (transil 8 kV 1.2/50 µs)
RS 485 data switching Time switching / Time delay transmission/reception 27 µs ...10 ms
Baud rate / Transmission distance from 1.2 to 500 kbits/s / max. 1200 m up to 38.4 kbit/s
Connections 2.5 mm² screw (AWG 20)
Traffic indication
Voltage 1 yellow LED
Connections 2 green LED (RxD, TxD, )
EMC behavior
Electrostatic discharge EN 61000-4-2 level 3 6/8 kV
Radiated electromagnetic eld EN 61000-4-3 level 3 10 V/m
Burst EN 61000-4-4 level 3 1 kV
Electromagnetic compatibility EN 55022 class B
Other characteristics
Galvanic isolation between RS 232 / Power supply / RSS 422-RS 485
500 V DC
Conguration of the operating mode using internal DIP switches
Operating temperature 0°C ... +50°C
Storage temperature -25°C ... +80°C
Mounting any required
DIN rail xing (EN 50002) snap-on mounting
Wire size 2.5 mm² / stranded with ferrule, 4 mm² solid
Dimensions (WxDxH) 88 x 22.5 x 100 mm
Weight 100 g
Caution :
The transmission channels of both
RS 422 - RS 485 serial link interfaces always have
to be independently polarized.
RS 422 - RS 485
4 wire serial link
24 V DC
power supply
Connector J1
RS 422 - RS 485
2 wire serial link
24 V DC
power supply
Connector J1
Serial data converters
Technical data
Signal converters
Low Voltage Products & Systems 12.41
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 232 / FO
Power supplies
Supply voltage 24...42 V AC/DC (50/60 Hz) 110...240 V AC/DC (50/60 Hz)
Voltage tolerance -15% ... +10% -15% ... +10%
Connections Omniconnect pluggable connector
Interface 1: RS 232 CCITT V.24/DIN 66020- CCITT V.28 DIN 66259-EIA 232 E
Protection Integrated (transil 8 kV 1.2/50µs)
Max. speed / max. distance Max. 115.2 kbits/s / max. 15 m / 2500 pF
Connections Omniconnect pluggable connector
Fiber optic interface 2 DIN VDE 0888-1
Type of ber / Connections Multimode ber
Glass : ST connector; Plastic : FSMA screw connector
Wave length Glass : 820 nm; Plastic : 655 nm
Max. transmission power Glass : 50/125 µm : -14.4 db/m; Glass : 62.5/125 µm : -14 db/m; Plastic : 980/1000 µm : -8 db/m
Max. reception power Glass : -28 db/m; Plastic : -20 db/m
Max. speed Max. 115.2 kbits/s
Max. distance Glass : 50/125 µm : 3 km; Glass : 62.5/125 µm : 4 km; Plastic : 980/1000 µm : 40 m
Status indication
Power supply / Data exchange 1 green LED / 2 green LEDs (RxD, TxD)
EMC behavior
Electrostatic discharge EN 61000-4-2 Level 3 6/8 kV
Radiated electromagnetic eld EN 61000-4-3 Level 3 10 V/m
Burst EN 61000-4-4 Level 3 1 kV
Electromagnetic compatibility EN 55022 Class B
Other characteristics
Galvanic isolation input / power supply / output 2.5 kV
Operating temperature -20°C ... +60°C
Storage temperature -40°C ... +85°C
Mounting Onto DIN Rail (EN 50002)
Connections 14 AWG (2.5 mm²) ne stranded / 12 AWG (4 mm²) rigid
Dimensions (WxDxH) 105 x 22.5 x 112 mm / 4.13 x 0.89 x 4.41"
Weight 150 g / 0.33 lb
RxD
OV
TxD
OV
~
+
~
-
(L)
(K)
(M)
(J HG)
(E)
(F)(D)
(B)
(C)
(A)
Shielding
FO Sending
FO Receiving
Shielding
Serial data converters
Technical data
Signal converters
12.42 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 485 / FO
Power supplies
Supply voltage 24...42 V AC/DC (50/60 Hz) 110...240 V AC/DC (50/60 Hz)
Voltage tolerance -15% ... +10% -15% ... +10%
Connections Omniconnect pluggable connector
Interface 1: RS 232 ISO / IEC 8482 / DIN 66 259-4; EIA 485
Protection Integrated (transil 8 kV 1.2/50µs)
Max. speed / max. distance Max. 1.5 Mbits/s / max. 1200 m (38.4 kbit/s)
Connections Omniconnect pluggable connector
Fiber optic interface 2 DIN VDE 0888-1
Type of ber / Connections Multimode ber
Glass : ST connector; Plastic : FSMA screw connector
Wave length Glass : 820 nm; Plastic : 655 nm
Max. transmission power Glass : 50/125 µm : -14.4 db/m; Glass : 62.5/125 µm : -14 db/m; Plastic : 980/1000 µm : -8 db/m
Max. reception power Glass : -28 db/m; Plastic : -20 db/m
Max. speed Max. 1.5 Mbits/s
Max. distance Glass : 50/125 µm : 3 km; Glass : 62.5/125 µm : 4 km; Plastic : 980/1000 µm : 40 m
Status indication
Power supply / Data exchange 1 green LED / 2 green LEDs (RxD, TxD)
EMC behavior
Electrostatic discharge EN 61000-4-2 Level 3 6/8 kV
Radiated electromagnetic eld EN 61000-4-3 Level 3 10 V/m
Burst EN 61000-4-4 Level 3 1 kV
Electromagnetic compatibility EN 55022 Class B
Other characteristics
Galvanic isolation input / power supply / output 2.5 kV
Operating temperature -20°C ... +60°C
Storage temperature -40°C ... +85°C
Mounting Onto DIN Rail
Connections 14 AWG (2.5mm²) / ne stranded, 12 AWG (4 mm²) rigid
Dimensions (WxDxH) 105 x 22.5 x 112 mm / 4.13 x 0.89 x 4.41"
Weight 150 g / 0.33 lb
OV
D -
D +
Shielding
FO Sending
FO Receiving
OV
~
-~
+
Shielding
Serial data converters
Technical data
Signal converters
Low Voltage Products & Systems 12.43
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
12 12
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 422 - 485 (for current loop)
Power supply DC model polarized
Voltage 24 V DC
Voltage tolerance +/-10%
Supply current 120 mA max.
Connections Removable screw connector (Omniconnect)
Interface 1: Current loop active/passive 0...20 mA / 4...20 mA, mode is settable
Logic level 0 = 20 mA or 1 = 20 mA, settable
Baud rate / Transmission distance max. 38.4 kbit/s / max. 1200 m
Connections 2.5 mm² screw (AWG 20)
Serial link 2: RS 422/485 EIA RS 485 and EIA RS 422 / CCITT V 11
Overvoltage protection integrated (transil 8 kV 1.2/50 µs)
Baud rate / Transmission distance max. 38.4 kbit/s / max. 1200 m
Connections 2.5 mm² screw (AWG 20)
Traffic indication
Voltage 1 yellow LED
Status of signal 2 green LED (RxD, TxD)
EMC behavior
Electrostatic discharge EN 61000-4-2 level 2 4/4 kV
Radiated electromagnetic eld EN 61000-4-3 level 3 10 V/m
Burst EN 61000-4-4 level 1 0.5 kV
Electromagnetic compatibility EN 55022 class B
Other characteristics
Galvanic isolation between input / output and power supply / output
depending on Current Loop (active/passive); 500 V DC (active) / 2000 V DC (passive)
RS 422-485 power supply 500 V DC
Conguration of the operating mode using internal DIP switches
Operating temperature 0°C ... +50°C
Storage temperature -25°C ... +80°C
Mounting any required
DIN rail xing (EN 50002) snap-on mounting
Wire size 2.5 mm² / stranded with ferrule, 4 mm² solid
Dimensions (WxDxH) 88 x 22.5 x 100 mm
Weight 100 g
RS 422 - RS 485
2 wire serial link
CONNECTIONS
Example of connection with a CL (current
Loop) product, Transmission (TxD) in active
mode and Reception (RxD) in passive mode.
Then, the ILPH must be congured and con-
nected Reception (RxD) in passive mode and
Transmission (TxD) in active mode.
Note : For any other conguration, see sche-
matic diagram or front sticker of the product.
Current Loop
Connector J1
24 V DC
power supply
Note :
The TxD channel of the RS 422 - RS 485
link must be polarized independently too.
RS 422 - RS 485
4 wire serial link
Current Loop
Connector J1
24 V DC
power supply
Serial data converters
Technical data
Signal converters
12.44 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
12 12
Technical data
Data at Ta = 25 °C and rated values, unless otherwise indicated
ILPH RS 223 / CL
Power supply DC model polarized
Voltage 24 V DC
Voltage tolerance +/-10%
Supply current 120 mA max.
Connections Removable screw connector (Omniconnect)
Serial link 2: RS 232 EIA RS 232 C / CCITT V 24 V 28
Logic level integrated (transil 8 kV 1.2/50 µs)
Baud rate / Transmission distance max. 38.4 kbit/s / max. 15 m
Connections 2.5 mm² screw (AWG 20)
BdC serial link 2: RS 422/485 active/passive 0...20 mA / 4...20 mA mode settable
Overvoltage protection 0=20 mA or 1=20 mA settable
Baud rate / Transmission distance max. 38.4 kbit/s / max. 1200 m
Connections 2.5 mm² screw (AWG 20)
Traffic indication
Voltage 1 yellow LED
Status signal 2 green LED (RxD, TxD)
EMC behavior
Electrostatic discharge EN 61000-4-2 level 3 6/8 kV
Radiated electromagnetic eld EN 61000-4-3 level 3 10 V/m
Burst EN 61000-4-4 level 3 1 kV
Electromagnetic compatibility EN 55022 class B
Other characteristics
Galvanic isolation between Current loop / RS 232
depending on current loop (active/passive) 500 V DC (active) / 2000 V DC (passive)
Galvanic isolation between Current loop / power supply
500 V DC (active) / 2000 V DC (passive)
Conguration of the operating mode using internal DIP switches
Operating temperature 0°C ... +50°C
Storage temperature -25°C ... +80°C
Mounting any required
DIN rail xing (EN 50002) snap-on mounting
Wire size 2.5 mm² / stranded with ferrule, 4 mm² solid
Dimensions (WxDxH) 88 x 22.5 x 100 mm
Weight 100 g
Current loop
24 V DC
power
supply
CONNECTIONS
Example of connection with a CL
(Current Loop) product,
Transmission (TxD) in active mode
and Reception (RxD) in passive
mode. Then, the ILPH must be
congured and connected Recep-
tion (RxD) in passive mode and
Transmission (TxD) in active mode.
CAUTION : For any other congu-
ration, see schematic diagram or
front sticker of the product.
Serial data converters
Technical data