PGFI Series 30 Amp Multi-Phase Portable Series (Cord) GFCI / ELCI INTRODUCTION The LineGardTM 30 Amp Portable Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. Available with an operating voltage of 120/240 VAC, 3O 120/208 VAC, 3O 240 VAC (certified to CSA 22.2 only) or 3O 208 VAC, 3O 277 VAC (UL 1053 compliant). This product can be integrated during after-market equipment upgrades or used as a stand-alone portable cordset. All units are MADE IN THE USA and are listed per UL 943 and CSA 22.2 No.144. Note that any power cord integrated with this GFCI becomes OSHA compliant for portable power usage in confinded space: OSHA 29 CFR 1926.404 (b)(1)(ii) and OSHA 29 CFR 1926.405 (a)(2)(ii)(G). Additionally, these devices meet NEC requirement 590.6 (a) and (b). FEATURES Specifications Listing Type * Power and fault status indicators * * * * Double insulated user interface Industrial design for rough service Chemical and UV resistant enclosure cULus Listed as a Class A GFCI per UL 943 and CSA 22.2 No. 144 * 30 amp configurations in 120/240 VAC 4-wire, 3O 120/208 VAC 5-wire, 3O 240 VAC 4-wire, 3O 208 VAC 4-wire, 3O 277 VAC 4-wire (UL 1053) Rated Supply Voltage 120/240 VAC, 3O 120/208 VAC, 3O 240 VAC (CSA only), 3O 208 VAC, 3O 277 VAC (UL 1053) Rated Current Up to 30 Amps or rating of wiring device and/or cable Horse Power 1HP @ 120 VAC, 3HP @ 240 VAC Trip Level, Class A * NEMA 4X and 6P wet location rated (indoor / outdoor) * Available in automatic or manual reset configurations* cULus Listed Class A UL 943, UL 1053 CSA 22.2 No. 144 Phase Operating Frequency Reset Type1 Response Time Operating Temperature Operating Voltage Range Let-Go Voltage Open Neutral Protection Grounded Neutral Protection 5mA +/- 1mA Dual voltage and 3 phase 60 Hz Automatic or Manual 25mS max -35C to 66C 85% to 110% of rated VAC 60% of supply voltage Trips upon loss of neutral Trips if ground and neutral touch at load side 1. Manual configuration should be specified if automatic start-up after power restoration of circuit power creates an unsafe condition. 276 PGFI Series - 30 Amp Multi-Phase Portable (Cord) Series http://airpax.sensata.com/ Confined Space Construction Sites Application Opportunities: (NEC 590.6) Commercial Garages (NEC 511.12) Outdoor Signs (NEC 600.10) Fountains & Water Displays (NEC 680.58) Spa & Hot Tubs (NEC 680.40) Marinas & Boat Yards Electrical wet locations Power generators Agricultural equipment Outdoor electrical equipment Cement cutting equipment Portable electric heaters Submersible pumps Pipeline heaters Automotive garages Industrial part washers Outdoor signage De-icing equipment (roof heaters) OSHA 29 CFR 1926.404 (b)(1)(ii), OSHA 29 CFR 1926.405 (a)(2)(ii)(G) (NEC 555.3) Ground Fault / Equipment Leakage RELATED CODES DECISION TABLES PGFI - 4 3 0 9 N 1 Product Type 6 Connector N 1 2 2 Voltage 3 Ampacity 4 Reset Type C 120/240 VAC split O 3 0 Manual A 2' black, 10/4 SEOOW cable 1 Automatic 9 25' black, 10/4 SEOOW cable C 50' black, 10/4 SEOOW cable 30 amps 4 120/208 VAC 3O 7 240 VAC 3O 5 Cable Configuration None 8 208 VAC 3O B 277 VAC 3O *Note: 1. Manual configuration should be specified if automatic power-up, after power restoration of circuit power, could create an unsafe condition. 2. 120/208 VAC 3O configurations use 10/5 SEOOW cable Flying Leads (SEOOW) http://airpax.sensata.com/ PGFI Series - 30 Amp Multi-Phase Portable (Cord) Series 277