DATA SHEET APEX LT Series TRANSCEIVER MODULES ZALM-301-1 Integrated Transceiver Modules for ZigBee / IEEE 802.15.4 Evaluation Kit available: ZAXM-201-KIT-1 APEX LT MODULE ZALM-301-1 * EmberTM EM260 platform * Integrated IEEE 802.15.4 PHY and MAC * Dedicated network processor * SPI or UART interface to application microcontroller * Handles all ZigBee processing & timing intensive tasks N O T FO R R EC N O EW M M D EN ES D IG ED N DESCRIPTION Apex modules provide a cost-effective RF transceiver solution for 2.4GHz ZigBee and IEEE 802.15.4 data links and wireless networks. The ZALM-301-1 Apex LT module is based on EmberTM EM260 ZigBee network processor. Also onboard are a 100mW Power Amplifier and SPI-based microprocessor interface, providing you with the flexibility to choose an external microprocessor based on your application's needs. The APEX LT provide over 4000 feet of range and is designed to deliver constant RF output power across the 2.1 to 3.6V voltage input, ensuring consistent performance over the entire life of the battery. FEATURES * 1 - 100mW output power, software configured * Designed for EmberZNet networks * Miniature footprint: 1.00" x 1.275" * Integrated PCB trace antenna * Optional MMCX connector for external antenna * 16 RF channels (Channel 16 operates at reduced power levels) * Over 4000 feet of range * Integrated hardware support for Ember InSight Development Environment * Non-intrusive debug interface (SIF) * AES 128 bit encryption * Low power consumption * Constant RF output power over 2.1- 3.6 V voltage range * FCC, IC, and CE certified * RoHS compliant APPLICATIONS Automated Meter Reading * In meter applications * Thermostats * In-home display units Home & Building Automation * Security * HVAC control * Lighting control * Thermostats The information in this document is subject to change without notice, please confirm data is current. Document No: 0003-00-07-00-000 (Issue C) Date Published: April 29, 2010 Industrial Controls * Food processing controls * Traffic Management * Sensor Networks * Asset Management * Barcode reader * Patient Monitoring * Glucose monitor ZALM-300 Series ORDERING INFORMATION Part Number Description ZALM-301-1 Apex Lite 100mW transceiver module PCB Trace Antenna ZALM-301-1-B Apex Lite 100mW transceiver module PCB Trace Antenna Bulk (1 tray) ZALM-301-1C Apex Lite 100mW transceiver MMCX connector installed ZALM-301-1C-B Apex Lite 100mW transceiver MMCX connector installed Bulk (1 tray) Mins/Mults 160 pcs / 160 pcs 32 pcs / 32 pcs 5,120 pcs / 160 pcs N/A N O T FO R R EC N O EW M M D EN ES D IG ED N APEX LT ZALM-301 Order Number Status Not Recommended For New Design Discontinued ZALM-300 Series APEX LT MODULE BLOCK DIAGRAM 24 MHz XTAL PWR Reg ANT Castellation Edge Connector N O T FO R R EC N O EW M M D EN ES D IG ED N Ember EM260 ZigbeeTM SOC Micro processor Radio RF Front End (Renesas PA & Renesas Switch) APEX LT EVALUATION KIT CEL provides Apex Evaluation Kits to assist users in evaluating Apex and Apex LT modules. The key components of the Apex Evaluation Kit are the interface board and the CEL's Apex radio module. Apex LT module combines an Ember EM260 (Apex LT) transceiver IC with an NEC high gain Power Amplifier and a high performance NEC RFIC switch. The interface board features a serial communication interface, a power management module, peripherals such as potentiometer and accelerometer, and GPIO headers. The Evaluation Kit also contains four AA batteries and two USB cables. For more detail information regarding Apex Evaluation Kit, refer to the Apex Module Evaluation Kit User Guide document. (http:// www.cel.com/pdf/misc/apexseries_ug.pdf) Order Number Description ZAXM-201-KIT-1* Engineering Evaluation Kit * To evaluate the ZALM-301-1 module, please utilize the ZAXM-201-KIT-1 Kit Contents: * Evaluation Boards (2) * ZigBee Modules (2) * USB Cables (2) * AA Batteries (4) * Technical Information CD (1) ZALM-300 Series TABLE OF CONTENTS Introduction and Overview 1 Features.................................................................................................................................................................................................. 1 Applications............................................................................................................................................................................................ 1 Ordering Information............................................................................................................................................................................. 1 Apex LT Module Block Diagram............................................................................................................................................................ 3 Evaluation Kit......................................................................................................................................................................................... 3 N O T FO R R EC N O EW M M D EN ES D IG ED N Description.............................................................................................................................................................................................. System Level Function Apex LT Module Microprocessor........................................................................................................................................................... 5 Antenna................................................................................................................................................................................................... 5 Modes of Operation (TX, RX, Sleep)...................................................................................................................................................... 7 Processor ACTIVE.................................................................................................................................................................................. 7 Processor IDLE....................................................................................................................................................................................... 7 Power Amplifier Regulator Control Line................................................................................................................................................ 8 SIF Interface............................................................................................................................................................................................ 8 Host Protocol Interface Commands...................................................................................................................................................... 8 Electrical Specification Absolute Maximum Ratings................................................................................................................................................................... 9 Recommended (Operating Condition).................................................................................................................................................. 9 DC Characteristics.................................................................................................................................................................................. 9 RF Characteristics.................................................................................................................................................................................. 10 Pin Signal & Interfaces Pin Signals I/O Configuration................................................................................................................................................................ 10 Apex LT I/O Pin Assignment.................................................................................................................................................................. 11 Apex LT Module Dimensions................................................................................................................................................................. 12 PCB Copper Pattern Layout................................................................................................................................................................... 13 PCB Stencil Pattern................................................................................................................................................................................ 13 PCB Keep-Out Areas.............................................................................................................................................................................. 14 Processing 15 Agency Certifications 17 Shipment, Storage & Handling 18 References & Revision History 19 ZALM-300 Series APEX LT MODULE microprocessor APEX LT modules provide a connection to the Ember Serial API over the SPI allowing the application development to be completed on a host microprocessor of your choice. In addition to the SPI signals, two additional signals (nHOST_INT and nWAKE) provide a handshake mechanism. The module provides a slave device with all transactions initiated by the host. Please consult the EM260 datasheet for details on the SPI Protocol including: Physical Interface Configuration SPI Transactions SPI Protocol Timing Parameters & Waveforms Data Formatting SPI Commands & Responses Handling Resets and Power Cycling Transaction Examples N O T FO R R EC N O EW M M D EN ES D IG ED N * * * * * * * TOP VIEW ANTENNA APEX and APEX LT modules include an integrated PCB trace antenna. An optional MMCX connector can be specified, enabling connection to a 50-ohm external antenna of the user's choice. See Ordering Information. TOP VIEW TOP VIEW The PCB antenna employs an F-Antenna topology that is compact and supports an omni-directional radiation pattern.To maximize antenna efficiency, an adequate ground plane must be provided on the host PCB. If positioned correctly, the ground plane on the host board under the module can contribute significantly to antenna performance. The position of the module on the host board and overall design of the product enclosure contribute to antenna performance. Poor design effects radiation patterns and can result in reflection, diffraction, and/or scattering of the transmitted signal. Measured radiation patterns of these modules are available from California Eastern Labs and can be used to benchmark design performance. Here are some design guidelines to help ensure antenna performance: * * * * * Never place the ground plane or route copper traces directly underneath the antenna portion of the module. Never place the antenna close to metallic objects. In the overall design, ensure that wiring and other components are not placed near the antenna. Do not place the antenna in a metallic or metallized plastic enclosure. Keep plastic enclosures 1 cm or more from the antenna in any direction. ZALM-300 Series ANTENNA (Continued) Orientation of EUT Peak Gain was in the Horizontal Position. The receiver antenna was in the Horizontal Position. Frequency = 2405 MHz Frequency = 2440 MHz 90 5 0 -5 -10 -15 -20 -25 -30 120 120 30 150 5 0 -5 -10 -15 -20 -25 -30 60 30 N O T FO R R EC N O EW M M D EN ES D IG ED N 150 90 60 180 0 330 210 240 180 0 210 330 300 240 270 Vertical Polarization Gain (dBi) min: -26.1 max: -7.3 Vertical Polarization Gain (dBi) avg: -14.7 min: -24.7 max: +1.8 avg: -2.7 Frequency = 2480 MHz 90 120 150 5 0 -5 -10 -15 -20 -25 -30 60 30 180 0 210 330 240 300 270 Vertical Polarization Gain (dBi) min: -22.1 max: -8.7 avg: -13.9 Horizontal Polarization Gain (dBi) min: -15.2 max: +1.4 avg: -3.1 max: -9.6 avg: -14.8 Horizontal Polarization Gain (dBi) min: -8.1 max: +0.4 avg: -3.4 Horizontal Polarization Gain (dBi) min: -8.9 300 270 ZALM-300 Series MODES OF OPERATION The Apex LT supports three power modes: Processor ACTIVE, processor IDLE, and DEEP SLEEP. Processor ACTIVE In this mode all operations are running normally. Processor IDLE N O T FO R R EC N O EW M M D EN ES D IG ED N While in idle mode, code execution halts until any interrupt occurs. All modules of the EM260 including the radio continue to operate normally. The EmberZNet stack automatically invokes idle as appropriate. Deep Sleep To achieve the lowest power consumption, the module can be set in DEEP SLEEP mode. In this mode most of the functionalities of the modules are turned off with the exception of the critical functions such as GPIO pads and RAM that is powered by the high voltage supply (DCC_PADS). The module can be taken out of DEEP SLEEP in 3 ways: * Configuring the sleep timer to generate an interrupt after some periods of time. * Issuing external interrupt signal. * Issuing commands through the SIF interface. In DEEP SLEEP the current consumption of the module will drop to 5.0A (5.5A with optional 32.768kHz oscillator enabled). For more detail information on modes of operation refer to Ember EM260 datasheet available at Ember's website (www.ember.com) ZALM-300 Series POWER AMPLIFIER REGULATOR CONTROL LINE The APEX LT module includes a separate 1.8V regulator for a power amplifier bias that enables consistent module output performance over the wide 2.1 - 3.6 V voltage range. To prevent excessive sleep currents, this regulator should be disabled when the module is in sleep mode. An external pull up resistor option is provided on each module (R6) that allows the regulator to be constantly enabled. This option increases the sleep current of the module to a point well above the specified values. SPECIFICATIONS -- VPA_EN (APEX LT) Min Regulator enable voltage 0.95 Typ Max Unit V N O T FO R R EC N O EW M M D EN ES D IG ED N Parameter Regulator disable voltage 0.4 V Enable line current (VEN = 0) 0.1 A Enable line current (VEN = VDD) 10 A Turn on Time 250 sec On the APEX LT module the VPA_EN control must be provided by the host microprocessor. In normal operation, the VPA_ EN line must be set high. It must be set low when the module is put into sleep mode in conjunction with putting the EM260 into deep sleep. Upon module wake-up, a 250 sec turn-on time must be provided prior to any transmission, allowing the module's regulator to settle. Note that this 250sec requirement applies only to the external power amplifier, the wake-up time for the EM260 is separate from this value. If the application does not put the module to sleep or if sleep current is not an issue, the power amplifier regulator may be permanently enabled by tying the control line high. In this setup, the sleep current will increase by 80A over the 5A Standby Current figure provided in Electrical Specifications. SIF INTERFACE The APEX LT module provide access to the SIF module programming and debug interface. Consult the EM260 datasheet for further details on the following SIF features: * Production Testing * Firmware Download * Product Control and Characterization HOST PROTOCOL INTERFACE COMMANDS For information on Host Protocol Interface Commands and for other software-related documents refer to Ember's website: http://www.ember.com/products_documentation.html ZALM-300 Series ABSOLUTE MAXIMUM RATINGS Rating Power Supply Voltage Voltage on Any Digital Pin RF Input Power Storage Temperature Range Value Unit 3.6 Vdc VDD + 0.3, Max 3.6 Vdc +10 dBm -45 to 125 C N O T FO R R EC N O EW M M D EN ES D IG ED N Note: Exceeding the maximum ratings may cause permanent damage to the module or devices. RECOMMENDED (OPERATING CONDITIONS) Characteristic Power Supply Voltage (VDD) Input Frequency Ambient Temperature Range Min Max Unit 2.1 3.6 V 2405 2480 MHz -40 Typ 85 C Logic Input Low Voltage 0 25 20% VDD V Logic Input High Voltage 80% VDD VDD V DC CHARACTERISTICS (@ 25C, VDD = 3.3V unless otherwise noted) Parameter Min Typ Max Unit 0.2 x VDD V Logic Input Low 0 Logic Input High 0.8 x VDD VDD V Logic Output Low 0 0.18 x VDD V Logic Output High 0.82 x VDD VDD V Power Consumption Transmit Mode (100mW output): APEX LT 170 mA 37 mA Receive Mode: APEX LT Standby Mode: 10mW 5 A 100mW 5 A ZALM-300 Series RF CHARACTERISTICS (@ 25C, VDD = 3.3V unless otherwise noted) Parameter Min Typ Max Unit General Charcteristics RF Frequency Range 2400 RF Data Rate 2483.5 MHz 250 kbps Nominal Output Power 20 dBm Programmable Output Power Range 32 Error Vector Magnitude 15 Transmitter dB % N O T FO R R EC N O EW M M D EN ES D IG ED N 35 Receiver Receiver Sensitivity (1% PER) - normal mode -92 -96 dBm Receiver Sensitivity (1% PER) - boost mode* -93 -97 dBm Saturation (Maximum Input Level) (1% PER) 0 dBm 30 dB 40 dB 30 dB 802.15.4 Adjacent Channel Rejection: APEX LT 802.15.4 Alternate Channel Rejection 802.11 g Rejection (10 MHz): APEX LT *Boost Mode is an optional software-selectable high performance mode designed to increase receiver sensitivity. Note: Refer to Ember EM260 datasheet for additional details. PIN SIGNALS I/O PORT CONFIGURATION The APEX LT module has a 28 edge I/O interfaces for connection to the user's host board. Figure 1 shows the layout of the 28 edge castellations. PIN 19 PIN 10 PIN 28 PIN 1 Figure 1 (Top View) ZALM-300 Series APEX LT I/O pin assignments Pin # Name Type Description 1 GROUND GND Ground 2 GROUND GND Ground 3 GROUND GND Ground 4 GROUND GND 5 VDD PI Power Supply Input 6 nRESET DI Reset, active low 7 MOSI DI SPI Data, Master Out/Slave In (from Host to APEX LT) 8 MISO DO SPI Data, Master In/Slave Out (from APEX LT to Host) 9 SCLK DI SPI Clock (from Host to APEX LT) 10 VPA_EN DI APEX LT Enable, active high (see section of "Power Amplifier Regulator Control Line") 11 nRTS DO UART RTS 12 nSSEL_INT/nCTS DI SPI Slave Select (from Host to APEX LT)/UART CTS 13 PTI_EN DO PTI Frame signal 14 PTI_DATA DO PTI Data signal 15 TXD DO UART TXD 16 nHOST_INT/RXD DO/DI 17 nWAKE DI 18 GROUND GND N O T FO R R EC N O EW M M D EN ES D IG ED N Ground Host Interrupt Signal (from APEX LT to Host) or UART RXD Wake Interrupt Signal (from host to APEX LT) Ground 19 SIF_CLK DI SIF Interface clock 20 SIF_MISO DO SIF Interface master in/slave out 21 SIF_MOSI DI SIF Interface master out/slave in 22 nSIF_LOAD DI/DO 23 SDBG DO Spare Debug Signal 24 LINK_ACTIVITY DO Link and Activity signal 25 GROUND GND Ground 26 GROUND GND Ground 27 GROUND GND Ground 28 GROUND GND Ground SIF Interface load strobe Unused I/O pins should be left unconnected and the pin state set via the Host Protocol. DI = Digital Input PI = Power Input DO = Digital Output GND = Ground AI = Analog Input AO = Analog Output ZALM-300 Series DIMENSIONS: ZALM-301-1 Apex LT PiN 11: nRTS nSSEL_INT/nCTS PTI_EN PTI_DATA TXD nHOST_INT/RXD 0.195 MAX nWAKE PiN 18: GROUND Dimensions in inches. Tolerances = +/-0.005" unless otherwise noted. PiN 19: SIF_CLK PiN 10: VPA_EN SCLK SIF_MOSI MISO N O T FO R R EC N O EW M M D EN ES D IG ED N SIF_MISO 1.275 0.909 nSIF_LOAD RF Shield MOSI SDBG nRESET LINK_ACTIVITY VDD GROUND GROUND GROUND GROUND GROUND GROUND PiN 28: GROUND PiN 1: GROUND 0.062 1.000 PCB Trace Antenna TOP ViEW DIMENSIONS: ZALM-301-1C Apex LT with Optional MMCX Connector 1.275 0.909 PiN 19: SIF_CLK RF Shield SIF_MISO SCLK SIF_MOSI MISO nSIF_LOAD MOSI SDBG nRESET LINK_ACTIVITY VDD GROUND GROUND GROUND GROUND GROUND GROUND PiN 1: GROUND J2 J2 0.410 0.205 MAX Overall Height w/MMCX Connector PiN 11: nRTS PiN 10: VPA_EN PiN 28: GROUND 0.062 nSSEL_INT/nCTS PTI_EN PTI_DATA TXD nHOST_INT/RXD 0.195 MAX nWAKE PiN 18: GROUND Dimensions in inches. Tolerances = +/-0.005" unless otherwise noted. 1.000 Optional MMCX Connector for external antenna TOP ViEW ZALM-300 Series PCB COPPER PATTERN LAYOUT: Apex LT Dimensions in inches. Tolerances = +/-0.005" unless otherwise noted. 0.040 0.100 Pitch Typ 0.125 Typ 28 Pads 0.040 N O T FO R R EC N O EW M M D EN ES D IG ED N 0.025 0.970 0.070 Typ 28 Pads 0.090 0.050 28 PIN 1 0.240 0.025 0.850 Recommended Host PCB Board Edge PCB PASTE STENCIL PATTERN: Apex LT Dimensions in inches. Tolerances = +/-0.005" unless otherwise noted. 0.065 0.100 Pitch Typ 0.100 Typ 28 Pads 0.065 0.070 Typ 28 Pads 28 PIN 1 0.900 ZALM-300 Series PCB Keep-out areas: Apex LT Dimensions in inches. Tolerances = +/-0.005" unless otherwise noted. 1.275 N O T FO R R EC N O EW M M D EN ES D IG ED N Component Keep Out Area: No components within 0.100 inches of module Edge of Host PCB 0.190 Recommended overhang for PCB Antenna = 0.230 0.315 0.050 If module does not overhang edge of host PCB, no components, copper or traces are allowed in this area 1.000 1.200 If optional MMCX connector is specified, edge of host board must be notched as shown For optimum antenna performance, the APEX LT modules should be mounted with the PCB trace antenna overhanging the edge of the host board. To further improve performance, a ground plane may be placed on the host board under the module, up to the PCB edge. The installation of an uninterrupted ground plane on a layer directly beneath the module will also allow you to run traces under this layer. CEL can provide assistance with your PCB layout. ZALM-300 Series PROCESSING Recommended Reflow Profile Parameters Values 3/sec max Minimum Soak Temperature 150C Maximum Soak Temperature 200C Soak Time 60-120 sec TLiquidus 217C Time above TL 60-150 sec Tpeak 260 + 0C Time within 5 of Tpeak 20-30 sec Time from 25 to Tpeak 8 min max Ramp down rate 6C/sec max N O T FO R R EC N O EW M M D EN ES D IG ED N Ramp up rate (from Tsoakmax to Tpeak) Achieve the brightest possible solder fillets with a good shape and low contact angle. Pb-Free Soldering Paste Use of "No Clean" soldering paste is strongly recommended, as it does not require cleaning after the soldering process. Note: The quality of the solder joints on the castellations (`half vias') where they contact the host board should meet the appropriate IPC specification. See IPC-A-610-D Acceptability of Electronic Assemblies, section 8.2.4 Castellated Terminations. Cleaning In general, cleaning the populated modules is strongly discouraged. Residuals under the module cannot be easily removed with any cleaning process. * Cleaning with water can lead to capillary effects where water is absorbed into the gap between the host board and the module. The combination of soldering flux residuals and encapsulated water could lead to short circuits between neighboring pads. Water could also damage any stickers or labels. * Cleaning with alcohol or a similar organic solvent will likely flood soldering flux residuals into the two housings, which is not accessible for post-washing inspection. The solvent could also damage any stickers or labels. * Ultrasonic cleaning could damage the module permanently. The best approach is to consider using a "no clean" soldering paste and eliminate the post-soldering cleaning step. Optical Inspection After soldering the Module to the host board, consider optical inspection to check the following: * Proper alignment and centering of the module over the pads. * Proper solder joints on all pads. * Excessive solder or contacts to neighboring pads, or vias. ZALM-300 Series PROCESSING (Continued) Repeating Reflow Soldering Only a single reflow soldering process is encouraged for host boards. Wave Soldering If a wave soldering process is required on the host boards due to the presence of leaded components, only a single wave soldering process is encouraged. N O T FO R R EC N O EW M M D EN ES D IG ED N Hand Soldering Hand soldering is possible. Use a soldering iron temperature setting equivalent to 350C, follow IPC recommendations/ reference document IPC-7711. Rework The Apex LT Module can be unsoldered from the host board. Use of a hot air re-work tool and hot plate for pre-heating from underneath is recommended. Avoid overheating. !Warning Never attempt a rework on the module itself, e.g. replacing individual components. Such actions will terminate warranty coverage. Additional Grounding Attempts to improve module or system grounding by soldering braids, wires, or cables onto the module RF shield cover is done at the customers own risk. The numerous ground pins at the module perimeter should be sufficient for optimum immunity to external RF interference. ZALM-300 Series AGENCY CERTIFICATIONS FCC Part 15.247 Module Certified (Mobile) The APEX LT modules comply with Part 15 of the Federal Communications Commission rules and regulations. To meet the FCC Certification requirements, the user must meet these regulations: * The text on the FCC ID label provided with the module must be placed on the outside of the final product. * The modules may only use the antennas that have been tested and approved with these modules: -- The on-board PCB trace antenna N O T FO R R EC N O EW M M D EN ES D IG ED N -- Nearson S131CL-5-RMM-2450S antenna. To meet the Section 15.209 emission requirements in the restricted frequency bands of Section 15.205, the transceiver transmitter power for the APEX LT (EM260) module needs to be reduced from the typical maximum setting on the upper two channels (2475 MHz and 2480 MHz). Maximum values are TBD. Per Section 2.109, the APEX LT module has been certified by the FCC for use with other products without additional certification. Any modifications to this product may violate the rules of the Federal Communications Commission and make operation of the product unlawful. Per Sections 15.107 and 15.109, the user's end product must be tested for unintentional radiators compliance. Per Section 47 C.F.R. Sec.15.105(b), the APEX LT modules is certified as mobile devices for the FCC radiation exposure limits set forth for an uncontrolled environment. The antennas used with these modules must be installed to provide a separation distance of at least 8 inches (20cm) from all persons. If the module is to be used in a handheld application, the user is responsible for passing additional FCC part 2.1091 rules (SAR) and FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields, OET Bulletin and Supplement C. IC Certification -- Canada The APEX LT module is IC certified. The labeling requirements for Industry Canada are similar to those of the FCC. A visible label on the outside of the final product must display the IC labeling. The user is responsible for the end product to comply with IC ICES-003 (Unintentional radiators). CE Certification -- Europe The APEX module is CE certified. The CE marking must be affixed legibly and indelibly to a visible location on the user's product. FCC Approved Antennas * Integrated PCB trace antenna * Nearson S131CL-5-RMM-2450S - A 2.4GHz Dipole antenna with a 5 inch cable and a right angle MMCX connector. ZALM-300 Series SHIPMENT, HANDLING, AND STORAGE Shipment The Apex LT Module is delivered in trays of 32. Each package consist of 5 trays and therefore the total module quantity per package is 160. Handling The Apex LT Module is designed and packaged to be processed in an automated assembly line. N O T FO R R EC N O EW M M D EN ES D IG ED N !Warning The Apex LT Module contain a highly sensitive electronic circuitry. Handling without proper ESD protection may destroy or damage the module permanently. !Warning According to JEDEC ISP, the Apex LT Module is moisture sensitive devices. Appropriate handling instructions and precautions are summarized in Section 2.1. Read carefully to prevent permanent damage due to moisture intake. Moisture Sensitivity Level (MSL) MSL 3, per J-STD-033 ZALM-300 Series REFERENCES & REViSION HISTORY References Reference Documents Apex Module Evaluation Kit User Guide Ember EM260 Datasheet (June 29, 2007) Revision History Changes to Current Version N O T FO R R EC N O EW M M D EN ES D IG ED N Previous Versions 0002/3-00-07-00-000 (Issue A) May 7, 2008 Initial preliminary datasheet. 0003-00-07-00-000 (Issue B) January 22, 2009 Datasheet Unification for ZigBee product line 0003-00-07-00-000 (Issue C) April 29, 2010 The following corrections/changes were made: On page 11, the module height was changed from 0.162" to 0.195". On page 6, the deep sleep mode current consumption was changed to 5.0A. Disclaimer * The information in this document is current as of the published date. The information is subject to change without notice. For actual design-in, refer to the latest publications of CEL data sheets or data books, etc., for the most up-to-date specifications of CEL products. Not all products and/or types are available in every country. Please check with an CEL sales representative for availability and additional information. * No part of this document may be copied or reproduced in any form or by any means without the prior written consent of CEL. CEL assumes no responsibility for any errors that may appear in this document. * CEL does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from the use of CEL products listed in this document or any other liability arising from the use of such products. No license, express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of CEL or others. * Descriptions of circuits, software and other related information in this document are provided for illustrative purposes in semiconductor product operation and application examples. The incorporation of these circuits, software and information in the design of a customer's *equipment shall be done under the full responsibility of the customer. CEL assumes no responsibility for any losses incurred by customers or third parties arising from the use of these circuits, software and information. * While CEL endeavors to enhance the quality, reliability and safety of CEL products, customers agree and acknowledge that the possibility of defects thereof cannot be eliminated entirely. To minimize risks of damage to property or injury (including death) to persons arising from defects in CEL products, customers must incorporate sufficient safety measures in their design, such as redundancy, fire-containment and anti-failure features. Page N/A N/A 6, 11