Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5339B5 Coax - CATV and MATV Applications For more Information please call 1-800-Belden1 General Description: Surveillance, CATV & MATV Cable, RG6, Rated-CM, 18 AWG solid bare copper, foamed polyolefin core, Duofoil(R)+60% aluminum braid, PVC jacket Physical Characteristics (Overall) Conductor AWG: # Coax AWG Stranding Conductor Material Dia. (mm) 1 18 Solid BC - Bare Copper 1.016 Total Number of Conductors: 1 Insulation Insulation Material: Insulation Material Dia. (mm) Gas-injected FPE - Foam Polyethylene 4.572 Outer Shield Outer Shield Material: Layer # Outer Shield Trade Name Type Outer Shield Material 1 Duofoil(R) 2 Coverage (%) Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100 Braid AL - Aluminum 60 Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Overall Cable Overall Nominal Diameter: 6.756 mm Mechanical Characteristics (Overall) Operating Temperature Range: -40C To +80C UL Temperature Rating: 75C Bulk Cable Weight: 41.670 Kg/Km Max. Recommended Pulling Tension: 302.478 N Min. Bend Radius/Minor Axis: 69.850 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM NEC Articles: 820 CEC/C(UL) Specification: CM EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes RG Type: 6/U Page 1 of 3 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5339B5 Coax - CATV and MATV Applications Series Type: Series 6 Flame Test UL Flame Test: UL1685 UL Loading C(UL) Flame Test: FT1 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) 75 Nom. Inductance: Inductance (H/m) 0.318257 Nom. Capacitance Conductor to Shield: Capacitance (pF/m) 53.4803 Nominal Velocity of Propagation: VP (%) 83 Nominal Delay: Delay (ns/m) 3.97001 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 21.3265 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 29.529 Max. Attenuation: Freq. (MHz) Attenuation (dB/100m) 5 2.65761 55 5.2496 211 10.1055 270 11.4835 300 12.1397 330 12.7631 400 14.1083 450 15.027 550 16.7003 750 19.686 870 21.3265 1000 22.967 Max. Operating Voltage - UL: Voltage 350 V RMS Put Ups and Colors: Item # Putup Ship Weight Color 5339B5 009U1000 1,000 FT 28.000 LB WHITE RG-6/U COAX 5339B5 009U500 500 FT 15.000 LB WHITE RG-6/U COAX 5339B5 0091000 1,000 FT 29.000 LB WHITE RG-6/U COAX 5339B5 009500 500 FT 15.000 LB WHITE RG-6/U COAX 5339B5 010U1000 1,000 FT 28.000 LB BLACK RG-6/U/COAX 5339B5 010500 500 FT 15.000 LB BLACK RG-6/U COAX Revision Number: 1 Notes Item Desc Revision Date: 03-11-2013 (c) 2015 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether Page 2 of 3 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5339B5 Coax - CATV and MATV Applications in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 01-09-2015