Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR Technical Product Specification Intel order number G34153-003 Revision 1.2 October, 2013 Enterprise Platforms and Services Division - Marketing Revision History Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Revision History Date February, 2012 Revision Number 1.0 Modifications Initial release. June, 2012 1.1 Updated thermal management and environmental summary. Updated onboard power connectors information. October, 2013 1.2 Added support for Intel(R) Xeon(R) processor E5-2600 v2 product family Updated memory support tables Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES, SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH, HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS' FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined". Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information. The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/literature. ii Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Table of Contents Table of Contents 1. Introduction .......................................................................................................................... 1 1.1 Chapter Outline ........................................................................................................ 1 1.2 Server Board Use Disclaimer .................................................................................. 1 2. Product Overview ................................................................................................................. 2 2.1 Product Feature Set ................................................................................................. 3 2.1.1 Main Board Connector and Component Layout ...................................................... 5 2.1.2 Main Board Rear I/O Layout .................................................................................... 8 2.1.3 Server Board Mechanical Drawings ...................................................................... 10 3. Functional Architecture ..................................................................................................... 19 3.1 Processor Support ................................................................................................. 20 3.1.1 Processor Socket Assembly .................................................................................. 20 3.1.2 Processor Population Rules .................................................................................. 21 3.1.3 Processor Initialization Error Summary ................................................................. 22 3.2 Processor Functions Overview .............................................................................. 25 3.2.1 Intel(R) QuickPath Interconnect ................................................................................ 26 3.2.2 Integrated Memory Controller (IMC) and Memory Subsystem .............................. 26 3.2.3 Processor Integrated I/O Module (IIO) ................................................................... 32 3.3 Intel(R) C600-A Chipset Functional overview ........................................................... 34 3.3.1 Digital Media Interface (DMI) ................................................................................. 34 3.3.2 PCI Express* Interface .......................................................................................... 34 3.3.3 Serial ATA (SATA) Controller ................................................................................ 34 3.3.4 Serial Attached SCSI (SAS)/SATA (SCU) Controller............................................. 35 3.3.5 AHCI ...................................................................................................................... 35 3.3.6 Rapid Storage Technology .................................................................................... 35 3.3.7 PCI Interface .......................................................................................................... 36 3.3.8 Low Pin Count (LPC) Interface .............................................................................. 36 3.3.9 Serial Peripheral Interface (SPI) ............................................................................ 36 3.3.10 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller) ..... 36 3.3.11 Advanced Programmable Interrupt Controller (APIC) ........................................... 36 3.3.12 Universal Serial Bus (USB) Controllers ................................................................. 36 3.3.13 Gigabit Ethernet Controller .................................................................................... 36 3.3.14 RTC ....................................................................................................................... 37 3.3.15 GPIO ...................................................................................................................... 37 3.3.16 Enhanced Power Management ............................................................................. 37 3.3.17 Manageability ......................................................................................................... 37 3.3.18 System Management Bus (SMBus* 2.0) ............................................................... 37 3.3.19 Integrated NVSRAM controller .............................................................................. 37 3.3.20 Virtualization Technology for Directed I/O (Intel(R) VT-d) ........................................ 38 3.3.21 JTAG Boundary-Scan ............................................................................................ 38 Revision 1.2 Intel order number G34153-003 iii Table of Contents Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 3.3.22 KVM/Serial Over Lan (SOL) Function .................................................................... 38 3.3.23 On-board SAS/SATA Support and Options ........................................................... 38 3.4 PCI Subsystem ...................................................................................................... 39 3.5 Network Interface Controller .................................................................................. 40 3.5.1 Network Interface ................................................................................................... 40 3.6 I/O Module Support (not avaiable for Intel(R) Server Board S2600IP4L and Intel(R) Workstation Board W2600CR2L) ............................................................................................ 41 3.7 SAS ROC Module Support .................................................................................... 42 3.8 HD Audio Support (Intel(R) Workstation Board W2600CR Only) ............................. 43 3.9 USB3.0 Support (Intel(R) Workstation Board W2600CR Only) ................................ 44 3.10 IEEE1394b Support (Intel(R) Workstation Board W2600CR Only) ........................... 45 4. Platform Management Overview ....................................................................................... 46 4.1 Server Management Function Architecture ........................................................... 46 4.1.1 Feature Support ..................................................................................................... 46 4.1.2 Basic and Advanced Features ............................................................................... 48 4.1.3 Integrated BMC Hardware: Emulex* Pilot III .......................................................... 49 4.2 Server Management Functional Specifications ..................................................... 51 4.2.1 BMC Internal Timestamp Clock ............................................................................. 51 4.2.2 System Event Log (SEL) ....................................................................................... 52 4.2.3 Sensor Data Record (SDR) Repository ................................................................. 52 4.2.4 Field Replaceable Unit (FRU) Inventory Device .................................................... 52 4.2.5 BMC Beep Codes .................................................................................................. 52 4.2.6 Diagnostic Interrupt (NMI) Button .......................................................................... 53 4.2.7 BMC Watchdog ...................................................................................................... 53 4.3 Sensor Monitoring .................................................................................................. 54 4.3.1 Overview ................................................................................................................ 54 4.3.2 Core Sensor List for EPSD Platforms Based on Intel(R) Xeon(R) Processor E5 4600/2600/2400/1600/1400 Product Families ...................................................................... 54 4.3.3 BMC System Management Health Monitoring ....................................................... 55 4.3.4 Processor Sensors ................................................................................................ 56 4.4 Thermal and Acoustic Management ...................................................................... 59 4.4.1 Set Throttling Mode ............................................................................................... 60 4.4.2 Altitude ................................................................................................................... 60 4.4.3 Set Fan Profile ....................................................................................................... 60 4.4.4 Fan PWM Offset .................................................................................................... 60 4.4.5 Quiet Fan Idle Mode .............................................................................................. 60 4.4.6 Thermal Sensor Input for Fan Speed Control ........................................................ 61 4.4.7 Power Supply Status\Health Sensors .................................................................... 62 4.4.8 System Event Sensor ............................................................................................ 63 4.5 Platform Management Interface ............................................................................ 64 4.5.1 Channel Management ........................................................................................... 65 iv Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Table of Contents 4.5.2 User Model ............................................................................................................ 65 4.5.3 LAN Interface ......................................................................................................... 65 4.6 BMC Firmware Update .......................................................................................... 75 4.6.1 The BMC firmware release Number ...................................................................... 75 4.6.2 Boot Recovery Mode ............................................................................................. 75 4.6.3 Force Firmware Update Jumper ............................................................................ 76 4.6.4 Fast Firmware Update over USB ........................................................................... 76 4.7 Advanced Management Feature Support .............................................................. 77 4.7.1 Enabling Advanced Management Features ........................................................... 77 4.7.2 Keyboard, Video, Mouse (KVM) Redirection ......................................................... 77 4.7.3 Media Redirection .................................................................................................. 78 4.8 Intel(R) Intelligent Power Node Manager (NM) ......................................................... 80 4.8.1 Overview ................................................................................................................ 80 4.9 EU Lot 6 Mode ....................................................................................................... 81 5. System Security ................................................................................................................. 82 5.1 BIOS Password Protection .................................................................................... 82 5.2 Trusted Platform Module (TPM) Support ............................................................... 84 5.2.1 TPM security BIOS ................................................................................................ 84 5.2.2 Physical Presence ................................................................................................. 85 5.2.3 TPM Security Setup Options ................................................................................. 85 5.3 Intel(R) Trusted Execution Technology ..................................................................... 87 6. Connector/Header Locations and Pin-outs ..................................................................... 88 6.1 Power Connectors ................................................................................................. 88 6.1.1 Main Power Connector .......................................................................................... 88 6.1.2 CPU Power Connectors ......................................................................................... 88 6.1.3 Add-in Card Power Connectors ............................................................................. 88 6.2 Front Panel Header and Connectors ..................................................................... 89 6.2.1 Front Panel Header ............................................................................................... 89 6.2.2 Front Panel USB Connector .................................................................................. 90 6.2.3 Local Control Panel Connector .............................................................................. 90 6.3 On Board Storage Connectors .............................................................................. 90 6.3.1 SATA Connectors: 6Gbps ..................................................................................... 90 6.3.2 Multiport Mini-SAS/SATA Connectors ................................................................... 91 6.3.3 Intel(R) RAID C600 Upgrade Key Connector............................................................ 92 6.3.4 HSBP_I2C Header ................................................................................................. 92 6.3.5 HDD LED Header .................................................................................................. 92 6.3.6 Internal Type- A USB Connector ........................................................................... 92 6.3.7 Internal eUSB SSD Header ................................................................................... 93 6.4 Management and Security Connectors ................................................................. 93 6.4.1 RMM4_Lite Connector ........................................................................................... 93 6.4.2 RMM4_NIC Connector .......................................................................................... 93 Revision 1.2 Intel order number G34153-003 v Table of Contents Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 6.4.3 TPM Connector ...................................................................................................... 94 6.4.4 PMBus* Connector ................................................................................................ 94 6.4.5 Chassis Intrusion Header ...................................................................................... 94 6.4.6 IPMB Connector .................................................................................................... 94 6.5 FAN Connectors .................................................................................................... 94 6.5.1 System FAN Connectors ....................................................................................... 95 6.5.2 CPU FAN Connector ............................................................................................. 95 6.6 Serial Port and Video Connectors ......................................................................... 95 6.6.1 Serial Port A Connector (DB9, for Intel(R) Server Board S2600IP only) .................. 95 6.6.2 Serial Port B Connector ......................................................................................... 96 6.6.3 Video Connector (For Intel(R) Server Board S2600IP only) ..................................... 96 6.6.4 Internal Video header (For Intel(R) Workstation Board W2600CR only) .................. 97 7. Jumper Blocks .................................................................................................................... 98 7.1 BIOS Default and Password Reset Usage Procedure ........................................... 99 7.1.1 Set BIOS to default (Clearing the CMOS) ............................................................. 99 7.1.2 Clearing the Password ........................................................................................... 99 7.2 Force BMC Update Procedure ............................................................................ 100 7.3 BIOS Recovery Jumper ....................................................................................... 100 7.4 ME Force Update Jumper .................................................................................... 101 (R) 8. Intel Light Guided Diagnostics ...................................................................................... 102 8.1 5-volt Stand-by LED ............................................................................................. 102 8.2 Fan Fault LED ...................................................................................................... 102 8.3 CPU Fault LED .................................................................................................... 102 8.4 DIMM Fault LEDs ................................................................................................ 104 8.5 System ID LED, System Status LED and POST Code Diagnostic LEDs ............ 104 8.5.1 System ID LED .................................................................................................... 105 8.5.2 System Status LED .............................................................................................. 106 8.5.3 POST Code Diagnostic LEDs .............................................................................. 107 9. Design and Environmental Specifications ..................................................................... 108 9.1 Products Design Specifications ........................................................................... 108 9.2 MTBF ................................................................................................................... 108 9.3 Server Board Power Requirements ..................................................................... 111 9.3.1 Processor Power Support .................................................................................... 112 9.4 Power Supply Output Requirements ................................................................... 112 9.4.1 Output Power/Currents ........................................................................................ 112 9.4.2 Cross Loading ...................................................................................................... 112 9.4.3 Standby Output .................................................................................................... 113 9.4.4 Voltage Regulation .............................................................................................. 113 9.4.5 Dynamic Loading ................................................................................................. 113 9.4.6 Capacitive Loading .............................................................................................. 114 9.4.7 Grounding ............................................................................................................ 114 vi Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Table of Contents 9.4.8 Closed loop stability ............................................................................................. 114 9.4.9 Residual Voltage Immunity in Standby mode ...................................................... 114 9.4.10 Common Mode Noise .......................................................................................... 114 9.4.11 Soft Starting ......................................................................................................... 115 9.4.12 Zero Load Stability Requirements ....................................................................... 115 9.4.13 Ripple/Noise ........................................................................................................ 115 9.4.14 Timing Requirements ........................................................................................... 115 Appendix A: Integration and Usage Tips .............................................................................. 118 Appendix B: BMC Sensor Tables .......................................................................................... 119 Appendix C: Platform Specific BMC Appendix .................................................................... 140 Introduction......................................................................................................................... 140 Product ID .......................................................................................................................... 140 IPMI Channel ID Assignments ........................................................................................... 140 ACPI S3 Sleep State Support ............................................................................................ 140 Processor Support for Intel(R) Server Board S2600IP .......................................................... 140 Supported Chassis ............................................................................................................. 140 Chassis-specific sensors .................................................................................................... 141 Hot-plug fan support ........................................................................................................... 141 Fan redundancy support .................................................................................................... 141 Fan domain definition ......................................................................................................... 142 HSC Availability .................................................................................................................. 144 Power unit support ............................................................................................................. 145 Redundant Fans only for Intel(R) Server Chassis ................................................................. 145 Fan Fault LED support ....................................................................................................... 145 Memory Throttling support ................................................................................................. 146 Introduction......................................................................................................................... 146 Product ID .......................................................................................................................... 146 IPMI Channel ID Assignments ........................................................................................... 146 ACPI S3 Sleep State Support ............................................................................................ 146 Processor Support for Intel(R) Server Board W2600CR ....................................................... 147 Supported Chassis ............................................................................................................. 147 Chassis-specific sensors .................................................................................................... 147 Hot-plug fan support ........................................................................................................... 147 Fan redundancy support .................................................................................................... 147 Board specific feature ......................................................................................................... 147 Fan domain definition ......................................................................................................... 147 HSC Availability .................................................................................................................. 148 Revision 1.2 Intel order number G34153-003 vii Table of Contents Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Power unit support ............................................................................................................. 148 Redundant Fans only for Intel(R) Server Chassis ................................................................. 148 Fan Fault LED support ....................................................................................................... 148 Memory Throttling support ................................................................................................. 148 Appendix D: POST Code Diagnostic LED Decoder ............................................................. 149 Appendix E: POST Error Messages and Handling .............................................................. 155 Glossary................................................................................................................................... 162 Reference Documents ............................................................................................................ 165 viii Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS List of Figures List of Figures Figure 1. Intel(R) Server Board S2600IP ......................................................................................... 2 Figure 2. Intel(R) Workstation Board W2600CR .............................................................................. 2 Figure 3. Intel(R) Server Board S2600IP Major Components .......................................................... 6 Figure 4. Intel(R) Server Board S2600IP Rear I/O Layout ............................................................... 8 Figure 5. Intel(R) Workstation Board W2600CR Rear I/O Layout .................................................... 9 Figure 6. Mounting Hole Locations (1 of 2) ................................................................................. 10 Figure 7. Mounting Hole Locations (2 of 2) ................................................................................. 11 Figure 8. Major Connector Pin-1 Locations (1 of 3) .................................................................... 12 Figure 9. Major Connector Pin-1 Locations (2 of 3) .................................................................... 13 Figure 10. Major Connector Pin-1 Locations (3 of 3) .................................................................. 14 Figure 11. Primary Side Keep-out Zone ..................................................................................... 16 Figure 12. Primary Side Card-Side Keep-out Zone .................................................................... 17 Figure 13. Second Side Keep-out Zone ...................................................................................... 18 Figure 14. Intel(R) Server Board S2600IP Functional Block Diagram ........................................... 19 Figure 15. Intel(R) Workstation Board W2600CR Functional Block Diagram ................................ 20 Figure 16. Processor Socket Assembly ...................................................................................... 21 Figure 17. Processor Socket ILM ................................................................................................ 21 Figure 18. Integrated Memory Controller Functional Block Diagram .......................................... 26 Figure 19. DIMM Slot Layout ...................................................................................................... 30 Figure 20. External RJ45 NIC Port LED Definition ..................................................................... 41 Figure 21. Supported I/O Module Options .................................................................................. 42 Figure 22. USB3.0 Discrete Host Controller Block Diagram ....................................................... 44 Figure 23. IEEE 1394b Discrete Host Controller Block Diagram ................................................ 45 Figure 24. Integrated BMC Hardware ......................................................................................... 51 Figure 25. High-level Fan Speed Control Process ...................................................................... 61 Figure 26. Setup Utility - TPM Configuration Screen ................................................................. 86 Figure 27. Video Connector Pin-out............................................................................................ 96 Figure 28. Jumper Blocks (J1C3, J1F1, J1F2, J2F3, J2F2) ....................................................... 98 Figure 29. Stand by LED, Fan Fault LED and CPU Fault LED Location .................................. 103 Figure 30. DIMM Fault LED's Location ..................................................................................... 104 Figure 31. Location of System Status, System ID and POST Code Diagnostic LEDs .............. 105 Figure 32. Power Distribution Block Diagram ........................................................................... 111 Figure 33. Differential Noise test setup ..................................................................................... 115 Figure 34. Output Voltage Timing ............................................................................................. 116 Figure 35. Turn On/Off Timing (Power Supply Signals) ............................................................ 117 Figure 36. POST Code Diagnostic LED Decoder ..................................................................... 149 Revision 1.2 Intel order number G34153-003 ix List of Tables Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS List of Tables Table 1. Product Feature Set ........................................................................................................ 3 Table 2. Mixed Processor Configurations Error Summary. ......................................................... 23 Table 3. UDIMM Support Guidelines .......................................................................................... 27 Table 4. RDIMM Support Guidelines .......................................................................................... 28 Table 5. LRDIMM Support Guidelines ........................................................................................ 29 Table 6. DIMM Nomenclature ..................................................................................................... 30 Table 7. Intel(R) RAID C600 Upgrade Key Options ....................................................................... 35 Table 8. Intel(R) Server Board S2600IP/Workstation Board W2600CR PCI Bus Segment Characteristics ...................................................................................................................... 39 Table 9. Supported Intel(R) Integrated RAID Modules................................................................... 43 Table 10. Standard Speaker Channels ....................................................................................... 44 Table 11. Basic and Advanced Features .................................................................................... 48 Table 12. BMC Beep Codes ....................................................................................................... 52 Table 13. NMI Signal Generation and Event Logging ................................................................. 53 Table 14. Supported BMC FW Health Sensor Offsets ................................................................ 56 Table 15. Processor Sensors ...................................................................................................... 56 Table 16. Processor Status Sensor Implementation ................................................................... 56 Table 17. Supported ERR2 Timeout Sensor Offsets .................................................................. 58 Table 18. Supported CATERR Sensor Offsets ........................................................................... 59 Table 19. Support MSID Mismatch Sensor Offsets .................................................................... 59 Table 20. Supported Power Supply Status Sensor Offsets ........................................................ 62 Table 21. Support System Event Sensor Offsets ....................................................................... 63 Table 22. Supported Firmware Update Status Sensor Offsets ................................................... 64 Table 23. Standard Channel Assignments ................................................................................. 65 Table 24. Supported RMCP+ Cipher Suites ............................................................................... 66 Table 25. Supported RMCP+ Payload Types ............................................................................. 66 Table 26. Factory Configured PEF Table Entries ....................................................................... 71 Table 27. Enabling Advanced Management Features ................................................................ 77 Table 28. TSetup Utility - Security Configuration Screen Fields ................................................ 86 Table 29. Main Power Connector Pin-out ................................................................................... 88 Table 30. CPU_1 Power Connector Pin-out ............................................................................... 88 Table 31. CPU_2 Power Connector Pin-out ............................................................................... 88 Table 32. Add-in Slot Power Pin-input ("OPT_12V_PWR") ........................................................ 89 Table 33. Front Panel Header Pin-out ........................................................................................ 89 Table 34. Front Panel USB Connector Pin-out ........................................................................... 90 Table 35. Local Front Panel Connector Pin-out .......................................................................... 90 Table 36. SATA 6Gbps Connector Pin-out ................................................................................. 90 x Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS List of Tables Table 37. Multiport SAS/SATA Connector Pin-out ("SCU_0 (0-3)")............................................ 91 Table 38. Multiport SAS/SATA Connector Pin-out ("SCU_1 (4-7)")............................................ 91 Table 39. Intel(R) RAID C600 Upgrade Key Connector Pin-out .................................................... 92 Table 40. HSBP_I2C Header Pin-out ......................................................................................... 92 Table 41. HDD LED Header Pin-out ........................................................................................... 92 Table 42. Type-A USB Connector Pin-out .................................................................................. 92 Table 43. eUSB SSD Header Pin-out ......................................................................................... 93 Table 44. RMM4_Lite Connector Pin-out .................................................................................... 93 Table 45. RMM4_NIC Connector Pin-out ................................................................................... 93 Table 46. TPM Connector Pin-out .............................................................................................. 94 Table 47. PMBus* Connector Pin-out ......................................................................................... 94 Table 48. Chassis Intrusion Header Pin-out ............................................................................... 94 Table 49. IPMB Connector Pin-out ............................................................................................. 94 Table 50. 6-pin System FAN Connector Pin-out ......................................................................... 95 Table 51. 4-pin System FAN Connector Pin-out ......................................................................... 95 Table 52. CPU FAN Connector Pin-out ...................................................................................... 95 Table 53. Serial Port A Connector Pin-out .................................................................................. 95 Table 54. Serial Port B Connector Pin-out .................................................................................. 96 Table 55. Video Connector Pin-out details ................................................................................. 96 Table 56. Server Board Jumpers (J1C3, J1F1, J1F2, J2F3, J2F2) ............................................ 98 Table 57. System Status LED ................................................................................................... 106 Table 58. POST Code Diagnostic LEDs ................................................................................... 107 Table 59. Server Board Design Specifications ......................................................................... 108 Table 60. Intel(R) Server Board S2600IP MTBF Estimate ........................................................... 109 Table 61. Intel(R) Workstation Board W2600CR MTBF Estimate ................................................ 109 Table 62. Intel(R) Xeon(R) Processor Dual Processor TDP profile ................................................. 112 Table 63. Minimum Load Ratings ............................................................................................. 112 Table 64. Loading Conditions ................................................................................................... 113 Table 65.Voltage Regulation Limits .......................................................................................... 113 Table 66. Transient Load Requirements ................................................................................... 113 Table 67. Capacitive Loading Conditions ................................................................................. 114 Table 68. Ripples and Noise ..................................................................................................... 115 Table 69. Output Voltage Timing .............................................................................................. 116 Table 70. Turn On/Off Timing ................................................................................................... 116 Table 71. Integrated BMC Core Sensors .................................................................................. 121 Table 72. Intel(R) Server Board S2600IP - BMC Channel Assignments ..................................... 140 Table 73. Intel(R) Server Board S2600IP - Chassis-specific Sensors ......................................... 141 Table 74. Intel(R) Server Board S2600IP - Fan Domain Definition .............................................. 142 Table 75. Intel(R) Server Chassis P4208/P4216/P4224/P4308 (UPL) Power support ................ 145 Table 76. Intel(R) Server Chassis R2208/R2216/R2224/R2308/R2312 (BHP) Power support ... 145 Table 77. Intel(R) Workstation Board W2600CR - BMC Channel Assignments .......................... 146 Revision 1.2 Intel order number G34153-003 xi List of Tables Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Table 78. Intel(R) Workstation Board W2600CR - Chassis-specific sensors ............................... 147 Table 79. Intel(R) Workstation Board W2600CR - Fan domain definition .................................... 147 Table 80. Intel(R) Server Chassis P4304 (UPL) Power support .................................................. 148 Table 81. POST Progress Code LED Example ........................................................................ 150 Table 82. POST Progress Codes ............................................................................................. 150 Table 83. MRC Progress Codes ............................................................................................... 152 Table 84. MRC Fatal Error Codes ............................................................................................ 153 Table 85. POST Error Codes and Messages ........................................................................... 155 Table 86. POST Error Beep Codes .......................................................................................... 160 Table 87. Integrated BMC Beep Codes .................................................................................... 161 xii Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS List of Tables Revision 1.2 Intel order number G34153-003 xiii Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 1. Introduction Introduction This Technical Product Specification (TPS) provides board-specific information detailing the features, functionality, and high-level architecture of the Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR. In addition, you can obtain design-level information for a given subsystem by ordering the External Product Specifications (EPS) for the specific subsystem. EPS documents are not publicly available and you must order them through your local Intel representative. 1.1 Chapter Outline This document is divided into the following chapters: 1.2 Chapter 1 - Introduction Chapter 2 - Product Overview Chapter 3 - Functional Architecture Chapter 4 - Platform Management Overview Chapter 5 - System Security Chapter 6 - Connector/Header Locations and Pin-outs Chapter 7 - Jumper Blocks Chapter 8 - Intel(R) Light Guided Diagnostics Chapter 9 - Design and Environmental Specifications Appendix A: Integration and Usage Tips Appendix B: BMC Sensor Tables Appendix C: Platform Specific BMC Appendix Appendix D: POST Code Diagnostic LED Decoder Appendix E: POST Error Messages and Handling Glossary Reference Documents Server Board Use Disclaimer (R) Intel Server Boards contain a number of high-density VLSI (Very-large-scale integration) and power delivery components that require adequate airflow for cooling. Intel ensures through its own chassis development and testing that when Intel(R) server building blocks are used together, the fully integrated system meets the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of the published operating or nonoperating limits. Revision 1.2 Intel order number G34153-003 1 Product Overview 2. Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Product Overview The Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR are Enterprise I/O Rich platforms for Pedestal and Rack Server and workstation market. Figure 1. Intel(R) Server Board S2600IP Figure 2. Intel(R) Workstation Board W2600CR 2 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 2.1 Product Overview Product Feature Set Table 1. Product Feature Set Board Name Processors Intel(R)Server Board S2600IP Support for one or two Intel(R) Xeon(R) E52600 Processor(s) and Intel(R) Xeon(R) E52600 v2 Processor(s) 8 GT/s Intel(R) Quick Path Interconnect (Intel(R) QPI) LGA 2011 Socket Thermal Design Power up to 135 W Intel(R)Workstation Board W2600CR Support for one or two Intel(R) Xeon(R) E52600 Processor(s) and Intel(R) Xeon(R) E52600 v2 Processor(s) 8 GT/s Intel(R) Quick Path Interconnect (Intel(R) QPI) LGA 2011 Socket Thermal Design Power up to 150 W Chipset Intel(R) C600-A chipset with support for optional Intel(R) C600 RAID Upgrade Keys Memory Slots 16 DDR3 DIMMs with 800MT/s, 1067MT/s, 1333MT/s,1600MT/s, *1866MT/s Eight memory channels (four channels for each processor socket) Channels A, B, C, D, E, F, G and H Support for Registered DDR3 Memory (RDIMM), Unbuffered DDR3 memory ((UDIMM) and Load Reduced DDR3 memory (LRDIMM) DDR3 standard I/O voltage of 1.5V and DDR3 Low Voltage of 1.35V Slot 1: PCIe Gen3 x16, connector from first processor. Slot 2: PCIe Gen3 x8, connector from first processor. Slot 3: PCIe Gen3 x16, connector from first processor. Slot 4: PCIe Gen3 x8, connector from second processor. Slot 5: PCIe Gen3 x16, connector from second processor. Slot 6: PCIe Gen3 x8, connector, from second processor Slot 7: PCIe Gen3 x16,connector, from second processor Slot 8: PCIe Gen2 x4 electrical with x8 physical connector, from second processor IOM Connector: I/O Module (optional with Flex Cable*) Notes: The IOM connector is not available for all boards and only supports PCIe Gen1 Speed SM Conn: SAS Module (optional) 6Gbps or 12Gbps SAS ROC module Options Ethernet Intel(R) I350 Quad 1GbE fully integrated GbE MAC and PHY Network Controller On-board storage controllers and options Video Revision 1.2 Intel(R) I350 Dual 1GbE fully integrated GbE MAC and PHY Controller One eUSB 2x5 pin connector to support 2mm low-profile eUSB solid state devices Two 7-pin single port AHCI SATA connectors capable of supporting up to 6 GB/sec Two SCU 4-port mini-SAS connectors capable of supporting up to 3 GB/sec SAS/SATA Intel(R) Integrated RAID module support (Optional) Intel(R) RAID C600 Upgrade Key support providing optional expanded SATA/SAS RAID capabilities Integrated Matrox* G200 2D Video Graphics controller 1 Rear VGA port Integrated Matrox* G200 2D Video Graphics controller 1 Internal VGA connector Intel order number G34153-003 3 Product Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Board Name Intel(R)Server Board S2600IP Intel(R)Workstation Board W2600CR Audio None ALC889 HD Audio (7.1 + S/PDIF Out) I/O 4 Rear USB2.0 1 Rear Serial A 2 Type A USB2.0 Connectors 1 Internal Serial B Server Management Onboard Server Engines* LLC Pilot III* Controller Support for Intel(R) Remote Management Module 4 solutions Intel(R) Light-Guided Diagnostics on field replaceable units Support for Intel(R) System Management Software Support for Intel(R) Intelligent Power Node Manager (Need PMBus*-compliant power supply) Security Intel(R) Trusted Platform Module (TPM) - AXXTPME5 (accessory option) Power-Supply 750W/1200W/1600W Common Redundant Power-Supply with PMBus* Support Suspend to RAM (S3) None Form Factor Custom 14.2'' W x 15.0'' D Chassis Pedestal: P4000L chassis 4 Rear USB2.0 2 Rear USB3.0 2 Type A USB2.0 Connector 1 1394b Connector 1 Internal Serial B Supported Pedestal: P4000L WS chassis 2U Rack: R2000 chassis *1866MT/s is only for Intel(R) Xeon(R) processor E5-2600 v2 product family 4 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 2.1.1 Product Overview Main Board Connector and Component Layout The following figure shows the layout of the server board. Each connector and major component is identified by a number or letter, and a description is given below the figure. Callout A B C D E F G H I J K Description Slot 1, PCI Express* Gen3 RMM4 lite module connector Slot 2, PCI Express* Gen3 TPM Slot 3, PCI Express* Gen3 Slot 4, PCI Express* Gen3 RMM4 Connector Slot 5, PCI Express* Gen3 Battery Slot 6, PCI Express* Gen3 Slot 7, PCI Express* Gen3 Revision 1.2 Callout AD AE AF AG AH AI AJ AK AL AM AN Intel order number G34153-003 Description DIMM C1/C2/D1/D2 System Fan connector 1/2/3/4/5/6 Type A USB connector Type A USB connector ROC Module connector LCP connector Front Panel connector Front Panel USB connector Main Power 4-pin connector MinISAS Port B(4-7) MiniSAS Port A(0-3) 5 Product Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Callout L M N O P Q R S T U V W X Y Z Description Slot 8, PCI Express* Gen2 DIMM E1/E2/F1/F2 Status LED ID LED Diagnostic LED NIC 3/4 (S2600IP only) USB 2/3, NIC 2 USB 0/1, NIC 1 VGA Port (S2600IP only) Serial Port A (S2600IP only) Processor 2 Power connector Processor 2 Fan connector DIMM H2/H1/G2/G1 PMBus* connector Main Power connector Callout AO AP AQ AR AS AT AU AV AW AX AY AZ BA BB BC AA Processor 1 Power connector BD AB AC DIMM B2/B1/A2/A1 Processor 1 Fan connector BE Description SATA Port 1 SATA Port 0 CPLD Update IPMB HDD LED ME FRC UPDT CMOS CLR BIOS RCVRY PASSWD CLR Storage Upgrade Key eUSB SSD HSBP connector Chassis intrusion Serial B connector BMC Force Update I/O Module connector (not available for S2600IP4L) System Fan connector 7 Figure 3. Intel(R) Server Board S2600IP Major Components 6 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Callout A B C D E F G H I J K L M N O P Description Slot 1, PCI Express* Gen3 RMM4 Lite module Slot 2, PCI Express* Gen3 TPM Slot 3, PCI Express* Gen3 Slot 4, PCI Express* Gen3 RMM4 Connector Slot 5, PCI Express* Gen3 Battery Slot 6, PCI Express* Gen3 Slot 7, PCI Express* Gen3 Slot 8, PCI Express* Gen2 DIMM E1/E2/F1/F2 Status LED ID LED Diagnostic LED Revision 1.2 Callout AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT Intel order number G34153-003 Product Overview Description DIMM C1/C2/D1/D2 System Fan connector 1/2/3/4/5/6 Type A USB connector Type A USB connector ROC Module connector LCP connector Front Panel connector Front Panel USB connector Main Power 4-pin connector 1394b connector(W2600CR only) MiniSAS Port B(4-7) MiniSAS Port A(0-3) SATA Port 1 SATA Port 0 CPLD Update IPMB 7 Product Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Callout Q R S T U V W X Y Z AA Description SPDIF connector USB 2/3, NIC 2 USB 0/1, NIC 1 USB3.0 0/1(W2600CR only) HD Audio (W2600CR only) Processor 2 Power connector Front Audio connector Processor 2 Fan connector DIMM H2/H1/G2/G1 PMBus* connector Main Power connector Callout AU AV AW AX AY AZ BA BB BC BD BE AB Processor 1 Power connector BF AC AD DIMM B2/B1/A2/A1 Processor 1 Fan connector BG BH Description HDD LED ME FRC UPDT CMOS CLR BIOS RCVRY PASSWD CLR Storage Upgrade Key eUSB SSD HSBP connector Chassis intrusion Serial B connector BMC Force Update I/O Module connector (not available for W2600CR2L) Internal video connector System Fan connector 7 Figure 3. Intel(R) Workstation Board W2600CR Major Components 2.1.2 Main Board Rear I/O Layout The following drawing shows the layout of the rear I/O components for the server boards. Callout A B C D Description Serial Port A Video Port NIC Port 1, USB Port 0 (bottom) and 1 (top) NIC Port 2, USB Port 2 (bottom) and 3 (top) Callout E F Description NIC Port 3(top) and 4(bottom) Diagnostics LED's G ID LED H Status LED Figure 4. Intel(R) Server Board S2600IP Rear I/O Layout 8 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Callout A B C D Description 7.1 Channel HD Audio Jack Connector USB3.0 Port 0(bottom) and 1(top) NIC Port 1, USB Port 0 (bottom) and 1 (top) NIC Port 2, USB Port 2 (bottom) and 3 (top) Callout E F G Product Overview Description Diagnostics LED's ID LED Status LED Figure 5. Intel(R) Workstation Board W2600CR Rear I/O Layout Revision 1.2 Intel order number G34153-003 9 Product Overview 2.1.3 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Server Board Mechanical Drawings Figure 6. Mounting Hole Locations (1 of 2) 10 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Product Overview Figure 7. Mounting Hole Locations (2 of 2) Revision 1.2 Intel order number G34153-003 11 Product Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Figure 8. Major Connector Pin-1 Locations (1 of 3) 12 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Product Overview Figure 9. Major Connector Pin-1 Locations (2 of 3) Revision 1.2 Intel order number G34153-003 13 Product Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Figure 10. Major Connector Pin-1 Locations (3 of 3) 14 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Revision 1.2 Intel order number G34153-003 Product Overview 15 Product Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Figure 11. Primary Side Keep-out Zone 16 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Product Overview Figure 12. Primary Side Card-Side Keep-out Zone Revision 1.2 Intel order number G34153-003 17 Product Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Figure 13. Second Side Keep-out Zone 18 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 3. Functional Architecture Functional Architecture The architecture and design of the Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR is based on the Intel(R) C600-A chipset. The chipset is designed for systems based on the Intel(R) Xeon(R) Sandy Bridge-EP Processor series in an LGA 2011 Socket with Intel(R) Quick Path Interconnect (Intel(R) QPI) speed at 8GT/s. This chapter provides a high-level description of the functionality associated with each chipset component and the architectural blocks that make up the server boards. Figure 14. Intel(R) Server Board S2600IP Functional Block Diagram Revision 1.2 Intel order number G34153-003 19 Functional Architecture Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Figure 15. Intel(R) Workstation Board W2600CR Functional Block Diagram 3.1 Processor Support The server board includes two Socket-R (LGA2011) processor sockets and can support one or two of the following processors - Intel(R) Xeon(R) processor E5-2600 and E5-2600 v2 product family with a Thermal Design Power (TDP) of up to 150W. Note: The 150w TDP processor is only supported on Intel(R) Workstation Board W2600CR and Intel(R) Server Board S2600IP only supports up to 135W TDP processors. Previous generation Intel(R) Xeon(R) processors are not supported on the Intel server boards described in this document. For a complete updated list of supported processors, please visit the support website. 3.1.1 Processor Socket Assembly Each processor socket of the server board is pre-assembled with an Independent Latching Mechanism (ILM) and Back Plate which allow for secure placement of the processor and processor heat to the server board. The illustration below identifies each sub-assembly component. 20 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Functional Architecture Heat Sink Server Board Independent Latching Mechanism (ILM) Back Plate Figure 16. Processor Socket Assembly 80mm 80mm Figure 17. Processor Socket ILM The square ILM has an 80x80mm heat sink mounting hole pattern and is used on the Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR. Note: Processor Thermal solutions for the Intel(R) Workstation Board W2600CR are NOT the same with Intel(R) Server Board S2600IP when install 150W TDP Processors. 3.1.2 Processor Population Rules Note: Although the server board does support dual-processor configurations consisting of different processors that meet the defined criteria below, Intel does not perform validation testing of this configuration. For optimal system performance in dual-processor configurations, Intel recommends that identical processors be installed. Revision 1.2 Intel order number G34153-003 21 Functional Architecture Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS When using a single processor configuration, the processor must be installed into the processor socket labeled "CPU_1". When two processors are installed, the following population rules apply: 3.1.3 Both processors must be of the same processor family. Both processors must have the same number of cores. Both processors must have the same cache sizes for all levels of processor cache memory. Processors with different core frequencies can be mixed in a system, given the prior rules are met. If this condition is detected, all processor core frequencies are set to the lowest common denominator (highest common speed) and an error is reported. Processors which have different QPI link frequencies may operate together if they are otherwise compatible and if a common link frequency can be selected. The common link frequency would be the highest link frequency that all installed processors can achieve. Processor stepping within a common processor family can be mixed as long as it is listed in the processor specification updates published by Intel Corporation. Processor Initialization Error Summary The following table describes mixed processor conditions and recommended actions for all Intel(R) server boards and Intel server systems designed around the Intel(R) Xeon(R) processor E5-2600 and E52600 v2 product family and Intel(R) C600 chipset product family architecture. The errors fall into one of the following three categories: Fatal: If the system can boot, it pauses at a blank screen with the text "Unrecoverable fatal error found. System will not boot until the error is resolved" and "Press to enter setup", regardless of whether the "Post Error Pause" setup option is enabled or disabled. When the operator presses the key on the keyboard, the error message is displayed on the Error Manager screen, and an error is logged to the System Event Log (SEL) with the POST Error Code. The system cannot boot unless the error is resolved. The user needs to replace the faulty part and restart the system. For Fatal Errors during processor initialization, the System Status LED will be set to a steady Amber color, indicating an unrecoverable system failure condition. Major: If the "Post Error Pause" setup option is enabled, the system goes directly to the Error Manager to display the error, and logs the POST Error Code to SEL. Operator intervention is required to continue booting the system. Otherwise, if "POST Error Pause" is disabled, the system continues to boot and no prompt is given for the error, although the Post Error Code is logged to the Error Manager and in a SEL message. 22 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Functional Architecture Minor: The message is displayed on the screen or on the Error Manager screen, and the POST Error Code is logged to the SEL. The system continues booting in a degraded state. The user may want to replace the erroneous unit. The POST Error Pause option setting in the BIOS setup does not have any effect on this error. Table 2. Mixed Processor Configurations Error Summary. Error Processor family not Identical Severity Fatal System Action The BIOS detects the error condition and responds as follows: Logs the POST Error Code into the System Event Log (SEL). Alerts the BMC to set the System Status LED to steady Amber. Displays "0194: Processor family mismatch detected" message in the Error Manager. Takes Fatal Error action (see above) and will not boot until the fault condition is remedied. Processor model not Identical Fatal The BIOS detects the error condition and responds as follows: Logs the POST Error Code into the System Event Log (SEL). Alerts the BMC to set the System Status LED to steady Amber. Displays "0196: Processor model mismatch detected" message in the Error Manager. Takes Fatal Error action (see above) and will not boot until the fault condition is remedied. Processor cores/threads not identical Fatal The BIOS detects the error condition and responds as follows: Logs the POST Error Code into the SEL. Alerts the BMC to set the System Status LED to steady Amber. Displays "0191: Processor core/thread count mismatch detected" message in the Error Manager. Takes Fatal Error action (see above) and will not boot until the fault condition is remedied. Processor cache not identical Fatal The BIOS detects the error condition and responds as follows: Logs the POST Error Code into the SEL. Alerts the BMC to set the System Status LED to steady Amber. Displays "0192: Processor cache size mismatch detected message in the Error Manager. Takes Fatal Error action (see above) and will not boot until the fault condition is remedied. Revision 1.2 Intel order number G34153-003 23 Functional Architecture Error Processor frequency (speed) not identical Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Severity Fatal System Action The BIOS detects the processor frequency difference, and responds as follows: Adjusts all processor frequencies to the highest common frequency. No error is generated - this is not an error condition. Continues to boot the system successfully. If the frequencies for all processors cannot be adjusted to be the same, then this is an error, and the BIOS responds as follows: Logs the POST Error Code into the SEL. Alerts the BMC to set the System Status LED to steady Amber. Does not disable the processor. Displays "0197: Processor speeds unable to synchronize" message in the Error Manager. Takes Fatal Error action (see above) and will not boot until the fault condition is remedied. Processor Intel(R) QuickPath Interconnect link frequencies not identical Fatal The BIOS detects the QPI link frequencies and responds as follows: Adjusts all QPI interconnect link frequencies to highest common frequency. No error is generated - this is not an error condition. Continues to boot the system successfully. If the link frequencies for all QPI links cannot be adjusted to be the same, then this is an error, and the BIOS responds as follows: Logs the POST Error Code into the SEL. Alerts the BMC to set the System Status LED to steady Amber. Displays "0195: Processor Intel(R) QPI link frequencies unable to synchronize" message in the Error Manager. Does not disable the processor. Takes Fatal Error action (see above) and will not boot until the fault condition is remedied. Processor microcode update missing Minor The BIOS detects the error condition and responds as follows: Logs the POST Error Code into the SEL. Displays "818x: Processor 0x microcode update not found" message in the Error Manager or on the screen. The system continues to boot in a degraded state, regardless of the setting of POST Error Pause in the Setup. Processor microcode update failed Major The BIOS detects the error condition and responds as follows: Logs the POST Error Code into the SEL. Displays "816x: Processor 0x unable to apply microcode update" message in the Error Manager or on the screen. Takes Major Error action. The system may continue to boot in a degraded state, depending on the setting of POST Error Pause in Setup, or may halt with the POST Error Code in the Error Manager waiting for operator intervention. 24 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 3.2 Functional Architecture Processor Functions Overview With the release of the Intel(R) Xeon(R) processor E5-2600 and E5-2600 v2 product family, several key system components, including the CPU, Integrated Memory Controller (IMC), and Integrated IO Module (IIO), have been combined into a single processor package and feature per socket; two Intel(R) QuickPath Interconnect point-to-point links capable of up to 8.0 GT/s, up to 40 lanes of Gen 3 PCI Express* links capable of 8.0 GT/s, and 4 lanes of DMI2/PCI Express* Gen 2 interface with a peak transfer rate of 5.0 GT/s. The processor supports up to 46 bits of physical address space and 48-bit of virtual address space. The following sections will provide an overview of the key processor features and functions that help to define the performance and architecture of the server board. For more comprehensive processor specific information, refer to the Intel(R) Xeon(R) processor E5-2600 and E5-2600 v2 product family documents listed in the Reference Document list. Processor Feature Details: Up to 8 execution cores for Intel(R) Xeon(R) processor E5-2600 product family Up to 12 execution cores for Intel(R) Xeon(R) processor E5-2600 v2 product family Each core supports two threads (Intel(R) Hyper-Threading Technology), up to 16 threads per socket for E5-2600 and 24 threads per socket for E5-2600 v2 46-bit physical addressing and 48-bit virtual addressing 1 GB large page support for server applications A 32-KB instruction and 32-KB data first-level cache (L1) for each core A 256-KB shared instruction/data mid-level (L2) cache for each core Up to 20 MB last level cache (LLC) for E5-2600: up to 2.5 MB per core instruction/data last level cache (LLC), shared among all cores Up to 30 MB last level cache (LLC) for E5-2600 v2: up to 2.5 MB per core instruction/data last level cache (LLC), shared among all cores Supported Technologies: Intel(R) Virtualization Technology (Intel(R) VT) Intel(R) Virtualization Technology for Directed I/O (Intel(R) VT-d) Intel(R) Virtualization Technology "Sandy Bridge" Processor Extensions Intel(R) Trusted Execution Technology (Intel(R) TXT) Intel(R) 64 Architecture Intel(R) Streaming SIMD Extensions 4.1 (Intel(R) SSE4.1) Intel(R) Streaming SIMD Extensions 4.2 (Intel(R) SSE4.2) Intel(R) Advanced Vector Extensions (Intel(R) AVX) Intel(R) Hyper-Threading Technology Execute Disable Bit Intel(R) Turbo Boost Technology Intel(R) Intelligent Power Technology Enhanced Intel(R) SpeedStep Technology Revision 1.2 Intel order number G34153-003 25 Functional Architecture 3.2.1 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Intel(R) QuickPath Interconnect The Intel(R) QuickPath Interconnect is a high speed, packetized, point-to-point interconnect used in the processor. The narrow high-speed links stitch together processors in distributed shared memory and integrated I/O platform architecture. It offers much higher bandwidth with low latency. The Intel(R) QuickPath Interconnect has an efficient architecture allowing more interconnect performance to be achieved in real systems. It has a snoop protocol optimized for low latency and high scalability, as well as packet and lane structures enabling quick completions of transactions. Reliability, availability, and serviceability features (RAS) are built into the architecture. The physical connectivity of each interconnect link is made up of twenty differential signal pairs plus a differential forwarded clock. Each port supports a link pair consisting of two unidirectional links to complete the connection between two components. This supports traffic in both directions simultaneously. To facilitate flexibility and longevity, the interconnect is defined as having five layers: Physical, Link, Routing, Transport, and Protocol. The Intel(R) QuickPath Interconnect includes a cache coherency protocol to keep the distributed memory and caching structures coherent during system operation. It supports both low-latency source snooping and a scalable home snoop behavior. The coherency protocol provides for direct cache-to-cache transfers for optimal latency. 3.2.2 Integrated Memory Controller (IMC) and Memory Subsystem CPU 1 CPU 2 2 DIMMs/Ch 2 DIMMs/Ch Integrated into the processor is a memory controller. Each processor provides four DDR3 channels that support the following: Figure 18. Integrated Memory Controller Functional Block Diagram 26 Unbuffered DDR3 and registered DDR3 DIMMs LR DIMM (Load Reduced DIMM) for buffered memory solutions demanding higher capacity memory subsystems Independent channel mode or lockstep mode Data burst length of eight cycles for all memory organization modes Memory DDR3 data transfer rates of 800, 1066, 1333, 1600 and 1866* MT/s 64-bit wide channels plus 8-bits of ECC support for each channel DDR3 standard I/O Voltage of 1.5 V and DDR3 Low Voltage of 1.35 V 1-Gb, 2-Gb, and 4-Gb DDR3 DRAM technologies supported for these devices: o UDIMM DDR3 - SR x8 and x16 data widths, DR - x8 data width o RDIMM DDR3 - SR,DR, and QR - x4 and x8 data widths o LRDIMM DDR3 - QR - x4 and x8 data widths with direct map or with rank multiplication Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Functional Architecture Up to 8 ranks supported per memory channel, 1, 2 or 4 ranks per DIMM Open with adaptive idle page close timer or closed page policy Per channel memory test and initialization engine can initialize DRAM to all logical zeros with valid ECC (with or without data scrambler) or a predefined test pattern Isochronous access support for Quality of Service (QoS) Minimum memory configuration: independent channel support with 1 DIMM populated Integrated dual SMBus* master controllers Command launch modes of 1n/2n RAS Support: o Rank Level Sparing and Device Tagging o Demand and Patrol Scrubbing o DRAM Single Device Data Correction (SDDC) for any single x4 or x8 DRAM device. Independent channel mode supports x4 SDDC. x8 SDDC requires lockstep mode o Lockstep mode where channels 0 and 1 and channels 2 and 3 are operated in lockstep mode o Data scrambling with address to ease detection of write errors to an incorrect address. o Error reporting from Machine Check Architecture o Read Retry during CRC error handling checks by iMC o Channel mirroring within a socket CPU1 Channel Mirror Pairs (A,B) and (C,D) CPU2 Channel Mirror Pairs (E,F) and (G,H) o Error Containment Recovery Improved Thermal Throttling with dynamic Closed Loop Thermal Throttling (CLTT) Memory thermal monitoring support for DIMM temperature *1866MT/s is only supported for E5-2600 v2 product family 3.2.2.1 Supported Memory Table 3. UDIMM Support Guidelines Ranks Per DIMM and Data Width Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel (DPC)2,3 Memory Capacity Per DIMM1 2 Slots per Channel 1DPC 1.35V 1.5V 1.35V Intel(R) Xeon(R) processor E5-2600 product family SRx8 ECC DRx8 ECC 1GB 2GB 4GB 2GB 4GB 8GB (R) 2DPC 1.5V 1066,1333 1066, 1333 1066 1066, 1333 1066,1333 1066, 1333 1066 1066, 1333 (R) Intel Xeon processor E5-2600 v2 product family 1066, 1333, SRx8 1GB 2GB 4GB 1066,1333 1066, 1333 1066, 1333, 1600 ECC 1600, 1866 1066, 1333, DRx8 2GB 4GB 8GB 1066,1333 1066, 1333 1066, 1333, 1600 ECC 1600,1866 Notes: 1. Supported DRAM Densities are 1Gb, 2Gb and 4Gb. Only 2Gb and 4Gb are validated by Intel. 2. Command Address Timing is 1N for 1DPC and 2N for 2DPC. Revision 1.2 Intel order number G34153-003 27 Functional Architecture Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Supported and Validated Supported but not Validate Table 4. RDIMM Support Guidelines Ranks Per DIMM and Data Width Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel (DPC)2 Memory Capacity Per DIMM1 2 Slots per Channel 1DPC 2DPC 1.35V 1.5V Intel(R) Xeon(R) processor E5-2600 product family 1.35V 1.5V SRx8 1GB 2GB 4GB 1066, 1333 1066, 1333, 1600 1066, 1333 1066, 1333, 1600 DRx8 2GB 4GB 8GB 1066, 1333 1066, 1333, 1600 1066, 1333 1066, 1333, 1600 SRx4 2GB 4GB 8GB 1066, 1333 1066, 1333, 1600 1066, 1333 1066, 1333, 1600 DRx4 4GB 8GB 16GB 1066, 1333 1066, 1333, 1600 1066, 1333 1066, 1333, 1600 QRx4 8GB 16GB 32GB 800 1066 800 800 QRx8 4GB 8GB 16GB 800 1066 800 800 Intel(R) Xeon(R) processor E5-2600 v2 product family SRx8 1GB 2GB 4GB 1066, 1333 1066, 1333, 1600, 1866 1066 1333 1066, 1333, 1600 DRx8 2GB 4GB 8GB 1066, 1333 1066, 1333, 1600, 1866 1066 1333 1066, 1333, 1600 SRx4 2GB 4GB 8GB 1066, 1333 1066, 1333, 1600, 1866 1066 1333 1066, 1333, 1600 DRx4 4GB 8GB 16GB 1066, 1333 1066, 1333, 1600, 1866 1066 1333 1066, 1333, 1600 QRx4 8GB 16GB 32GB 800 1066 800 800 QRx8 4GB 8GB 16GB 800 1066 800 800 Notes: 1. Supported DRAM Densities are 1Gb, 2Gb and 4Gb. Only 2Gb and 4Gb are validated by Intel(R). 2. Command Address Timing is 1N. 3. QR RDIMM are supported but only validated by Intel/PMO in a homogenous environment. The coverage will have limited system level testing, no signal integrity testing, and no interoperability testing the passing QR RDIMMs will be web posted. Supported and Validated Supported but not Validate Supported w/Limited Validation4 28 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Functional Architecture Table 5. LRDIMM Support Guidelines Ranks Per DIMM and Data Width1 Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel (DPC)3,4 2 Slots per Channel 1DPC 2DPC 1.5V 1.35V Memory Capacity Per DIMM2 1.35V 1.5V Intel(R) Xeon(R) processor E5-2600 product family QRx4 (DDP)5 QRx8 (P)5 16GB 32GB 1066 8GB 16GB 1066 (R) 1066, 1333 1066 1066, 1333 1066, 1333 1066 1066, 1333 (R) Intel Xeon processor E5-2600 v2 product family QRx4 16GB 32GB 1066, 1333 1066, 1333 1066, 1333 (DDP)5 QRx8 32GB 64GB 1066 1066 1066 (P)5 Notes: 1. Physical Rank is used to calculate DIMM Capacity. 2. Supported and validated DRAM Densities are 2Gb and 4Gb. 1066, 1333 1066 3. Command Address Timing is 1N. 4. The speeds are estimated targets and will be verified through simulation. 5. DDP - Dual Die Package DRAM stacking. P - Planer monolithic DRAM Die. Supported and Validated 3.2.2.2 Memory Population Rules Note: Although mixed DIMM configurations are supported, Intel only performs platform validation on systems that are configured with identical DIMMs installed. Each processor provides four banks of memory, each capable of supporting up to 2 DIMMs. DIMMs are organized into physical slots on DDR3 memory channels that belong to processor sockets. The memory channels from processor socket 1 are identified as Channel A, B, C and D. The memory channels from processor socket 2 are identified as Channel E, F, G, and H. The silk screened DIMM slot identifiers on the board provide information about the channel, and therefore the processor to which they belong. For example, DIMM_A1 is the first slot on Channel A on processor 1; DIMM_E1 is the first DIMM socket on Channel E on processor 2. The memory slots associated with a given processor are unavailable if the corresponding processor socket is not populated. A processor may be installed without populating the associated memory slots provided a second processor is installed with associated memory. In this case, the memory is shared by the processors. However, the platform suffers performance degradation and latency due to the remote memory. Processor sockets are self-contained and autonomous. However, all memory subsystem support (such as Memory RAS, Error Management,) in the BIOS setup are applied commonly across processor sockets. Revision 1.2 Intel order number G34153-003 29 Functional Architecture Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS On the Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR a total of 16 DIMM slots is provided (2 CPUs - 4 Channels/CPU, 2 DIMMs/Channel). The nomenclature for DIMM sockets is detailed in the following table: Table 6. DIMM Nomenclature (0) Channel A Processor Socket 1 (1) (2) Channel B Channel C (3) Channel D (0) Channel E Processor Socket 2 (1) (2) Channel F Channel G (3) Channel H A1 B1 D1 E1 F1 H1 A2 B2 C1 C2 D2 E2 F2 G1 G2 H2 Figure 19. DIMM Slot Layout The following are generic DIMM population requirements that generally apply to both the Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR. 30 DIMM slots on any memory channel must be filled following the "farthest fill first" rule. A maximum of 8 ranks can be installed on any one channel, counting all ranks in each DIMM on the channel. DIMM types (UDIMM, RDIMM, LRDIMM) must not be mixed within or across processor sockets. Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Functional Architecture Mixing ECC with non-ECC DIMMs (UDIMMs) is not supported within or across processor sockets. Mixing Low Voltage (1.35V) DIMMs with Standard Voltage (1.5V) DIMMs is not supported within or across processor sockets. Mixing DIMMs of different frequencies and latencies is not supported within or across processor sockets. LRDIMM Rank Multiplication Mode and Direct Map Mode must not be mixed within or across processor sockets. Only ECC UDIMMs support Low Voltage 1.35V operation. QR RDIMMs may only be installed in DIMM Slot 1 or 2 on a channel. 2 DPC QR Low Voltage RDIMMs are not supported. In order to install 3 QR LRDIMMs on the same channel, they must be operated with Rank Multiplication as RM = 2. RAS Modes Lockstep, Rank Sparing, and Mirroring are mutually exclusive in this BIOS. Only one operating mode may be selected, and it will be applied to the entire system. If a RAS Mode has been configured, and the memory population will not support it during boot, the system will fall back to Independent Channel Mode and log and display errors Rank Sparing Mode is only possible when all channels that are populated with memory meet the requirement of having at least 2 SR or DR DIMM installed, or at least one QR DIMM installed, on each populated channel. Lockstep or Mirroring Modes require that for any channel pair that is populated with memory, the memory population on both channels of the pair must be identically sized. DIMM population rules require that DIMMs within a channel be populated starting with the BLUE DIMM slot or DIMM farthest from the processor in a "fill-farthest" approach. In addition, when populating a Quad-rank DIMM with a Single- or Dual-rank DIMM in the same channel, the Quad-rank DIMM must be populated farthest from the processor. Note that Quad-rand DIMMs and UDIMMs are not allowed in three slots populated configurations. Intel MRC will check for correct DIMM placement. 3.2.2.3 Publishing System Memory The BIOS displays the "Total Memory" of the system during POST if Display Logo is disabled in the BIOS setup. This is the total size of memory discovered by the BIOS during POST, and is the sum of the individual sizes of installed DDR3 DIMMs in the system. The BIOS displays the "Effective Memory" of the system in the BIOS setup. The term Effective Memory refers to the total size of all DDR3 DIMMs that are active (not disabled) and not used as redundant units. The BIOS provides the total memory of the system in the main page of the BIOS setup. This total is the same as the amount described by the first bullet above. If Quite Boot is disabled, the BIOS displays the total system memory on the diagnostic screen at the end of POST. This total is the same as the amount described by the first bullet above. 3.2.2.4 RAS Features The server board supports the following memory RAS modes: Independent Channel Mode Rank Sparing Mode Revision 1.2 Intel order number G34153-003 31 Functional Architecture Mirrored Channel Mode Lockstep Channel Mode Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Regardless of RAS mode, the requirements for populating within a channel given in the section 3.2.2.2 must be met at all times. Note that support of RAS modes that require matching DIMM population between channels (Mirrored and Lockstep) require that ECC DIMMs be populated. Independent Channel Mode is the only mode that supports non-ECC DIMMs in addition to ECC DIMMs. For RAS modes that require matching populations, the same slot positions across channels must hold the same DIMM type with regards to size and organization. DIMM timings do not have to match but timings will be set to support all DIMMs populated (that is, DIMMs with slower timings will force faster DIMMs to the slower common timing modes). 3.2.2.4.1 Independent Channel Mode Channels can be populated in any order in Independent Channel Mode. All four channels may be populated in any order and have no matching requirements. All channels must run at the same interface frequency but individual channels may run at different DIMM timings (RAS latency, CAS Latency, and so forth). 3.2.2.4.2 Rank Sparing Mode In Rank Sparing Mode, one rank is a spare of the other ranks on the same channel. The spare rank is held in reserve and is not available as system memory. The spare rank must have identical or larger memory capacity than all the other ranks (sparing source ranks) on the same channel. After sparing, the sparing source rank will be lost. 3.2.2.4.3 Mirrored Channel Mode In Mirrored Channel Mode, the memory contents are mirrored between Channel 0 and Channel 2 and also between Channel 1 and Channel 3. As a result of the mirroring, the total physical memory available to the system is half of what is populated. Mirrored Channel Mode requires that Channel 0 and Channel 2, and Channel 1 and Channel 3 must be populated identically with regards to size and organization. DIMM slot populations within a channel do not have to be identical but the same DIMM slot location across Channel 0 and Channel 2 and across Channel 1 and Channel 3 must be populated the same. 3.2.2.4.4 Lockstep Channel Mode In Lockstep Channel Mode, each memory access is a 128-bit data access that spans Channel 0 and Channel 1, and Channel 2 and Channel 3. Lockstep Channel mode is the only RAS mode that allows SDDC for x8 devices. Lockstep Channel Mode requires that Channel 0 and Channel 1, and Channel 2 and Channel 3 must be populated identically with regards to size and organization. DIMM slot populations within a channel do not have to be identical but the same DIMM slot location across Channel 0 and Channel 1 and across Channel 2 and Channel 3 must be populated the same. 3.2.3 Processor Integrated I/O Module (IIO) The processor's integrated I/O module provides features traditionally supported through chipset components. The integrated I/O module provides the following features: 32 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 3.2.3.1 Functional Architecture PCI Express* Interfaces The integrated I/O module incorporates the PCI Express* interface and supports up to 40 lanes of PCI Express*. Following are key attributes of the PCI Express* interface: Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR supports PCI-e slots from two processors: From first processor: Slot 1: PCIe Gen3 x16 connector Slot 2: PCIe Gen3 x8 connector Slot 3: PCIe Gen3 x16 connector From second processor: Slot 4: PCIe Gen3 x8 connector Slot 5: PCIe Gen3 x16 connector Slot 6: PCIe Gen3 x8 connector Slot 7: PCIe Gen3 x16 connector Slot 8: PCIe Gen2 x4 electrical with x8 physical connector. Note: System will have video output on PCIe slots from first processor by default. If need add-in video card output on slots from second processor, please refer System Service guide to change Bios setup. 3.2.3.2 DMI2 Interface to the PCH The platform requires an interface to the legacy Southbridge (PCH) which provides basic legacy functions required for the server platform and operating systems. Since only one PCH is required and allowed for the system, any sockets which do not connect to PCH would use this port as a standard x4 PCI Express* 2.0 interface. 3.2.3.3 Integrated IOAPIC Provides support for PCI Express* devices implementing legacy interrupt messages without interrupt sharing. 3.2.3.4 Non Transparent Bridge PCI Express* non-transparent bridge (NTB) acts as a gateway that enables high performance, low overhead communication between two intelligent subsystems; the local and the remote subsystems. The NTB allows a local processor to independently configure and control the local subsystem, provides isolation of the local host memory domain from the remote host memory domain while enabling status and data exchange between the two domains. 3.2.3.5 4.2.3.1.5 Intel(R)QuickData Technology Used for efficient, high bandwidth data movement between two locations in memory or from memory to I/O. Revision 1.2 Intel order number G34153-003 33 Functional Architecture 3.3 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Intel(R)C600-A Chipset Functional overview The Intel(R) C600-A Chipset in the Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR provide a connection point between various I/O components and Intel(R) Xeon Sandy Bridge-EP processors, which includes the following core platform functions: Digital Media Interface (DMI) PCI Express* Interface Serial ATA (SATA) Controller Serial Attached SCSI (SAS)/SATA Controller AHCI Rapid Storage Technology PCI Interface Low Pin Count (LPC) Interface Serial Peripheral Interface (SPI) Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller) Advanced Programmable Interrupt Controller (APIC) Universal Serial Bus (USB) Controllers Gigabit Ethernet Controller RTC GPIO Enhanced Power Management Intel(R) Active Management Technology (Intel(R) AMT) Manageability System Management Bus (SMBus* 2.0) Integrated NVSRAM controller Virtualization Technology for Directed I/O (Intel(R) VT-d) JTAG Boundary-Scan KVM/Serial Over LAN (SOL) Function 3.3.1 Digital Media Interface (DMI) Digital Media Interface (DMI) is the chip-to-chip connection between the processor and The Intel(R) C600-A Chipset. This high-speed interface integrates advanced priority-based servicing allowing for concurrent traffic and true isochronous transfer capabilities. Base functionality is completely software-transparent, permitting current and legacy software to operate normally. 3.3.2 PCI Express* Interface (R) The Intel C600-A Chipset provides up to 8 PCI Express* Root Ports, supporting the PCI Express* Base Specification, Revision 2.0. Each Root Port x1 lane supports up to 5 Gb/s bandwidth in each direction (10 Gb/s concurrent). PCI Express* Root Ports 1-4 or Ports 5-8 can independently be configured to support four x1s, two x2s, one x2 and two x1s, or one x4 port widths. 3.3.3 Serial ATA (SATA) Controller (R) The Intel C600-A Chipset has two integrated SATA host controllers that support independent DMA operation on up to six ports and supports data transfer rates of up to 6.0 Gb/s (600 MB/s) on up to two 34 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Functional Architecture ports (Port 0 and 1 Only) while all ports support rates up to 3.0 Gb/s (300 MB/s) and up to 1.5 Gb/s (150 MB/s). The SATA controller contains two modes of operation - a legacy mode using I/O space, and an AHCI mode using memory space. Software that uses legacy mode will not have AHCI capabilities. The Intel(R) C600-A Chipset supports the Serial ATA Specification, Revision 3.0. The Intel(R) C600-A Chipset also supports several optional sections of the Serial ATA II: Extensions to Serial ATA 1.0 Specification, Revision 1.0 (AHCI support is required for some elements). 3.3.4 Serial Attached SCSI (SAS)/SATA (SCU) Controller (R) The Intel C600-A Chipset supports up to 8 SAS ports that are compliant with SAS 2.0 Specification and all ports support rates up to 3.0 Gb/s. All 8 ports are also independently configurable and compliant with SATA Gen2 and support data transfer rates of up to 3.0 Gb/s. SAS/SATA controller is only available on specific Intel(R) C600-A Chipset SKUs with optional RAID C600 Upgrade key. Certain SKUs are also limited to support 4 of 8 SAS/SATA ports only. Please refer details below: Note: SAS/SATA (SCU) port 0-3 is by default enabled while port 4-7 is disabled. Table 7. Intel(R) RAID C600 Upgrade Key Options Intel(R)RAID C600 Upgrade Key Options (Product Codes) Default - No option key installed Key Color RKSATA4R5 Black RKSATA8 Blue RKSATA8R5 White RKSAS4 Green RKSAS4R5 Yellow RKSAS8 Orange RKSAS8R5 Purple N/A Description 4 Port SATA with Intel(R) ESRT RAID 0,1,10 and Intel(R) RSTe RAID 0,1,5,10 4 Port SATA with Intel(R) ESRT2 RAID 0,1, 5, 10 and Intel(R) RSTe RAID 0,1,5,10 8 Port SATA with Intel(R) ESRT2 RAID 0,1, 10 and Intel(R) RSTe RAID 0,1,5,10 8 Port SATA with Intel(R) ESRT2 RAID 0,1, 5, 10 and Intel(R) RSTe RAID 0,1,5,10 4 Port SAS with Intel(R) ESRT2 RAID 0,1, 10 and Intel(R) RSTe RAID 0,1,10 4 Port SAS with Intel(R) ESRT2 RAID 0,1, 5, 10 and Intel(R) RSTe RAID 0,1,10 8 Port SAS with Intel(R) ESRT2 RAID 0,1, 10 and Intel(R) RSTe RAID 0,1,10 8 Port SAS with Intel(R) ESRT2 RAID 0,1, 5, 10 and Intel(R) RSTe RAID 0,1,10 Additional information for the on-board RAID features and functionality can be found in the Intel(R) RAID Software User's Guide (Intel Document Number D29305-019). 3.3.5 AHCI (R) The Intel C600-A Chipset provides hardware support for Advanced Host Controller Interface (AHCI), a standardized programming interface for SATA host controllers. Platforms supporting AHCI may take advantage of performance features. AHCI also provides usability enhancements such as Hot-Plug. AHCI requires appropriate software support (for example, an AHCI driver) and for some features, hardware support in the SATA device or additional platform hardware. 3.3.6 Rapid Storage Technology (R) The Intel C600-A Chipset provides support for Intel(R) Rapid Storage Technology, providing both AHCI and integrated RAID functionality. The RAID capability provides high-performance RAID 0, 1, 5 and 10 functionality on the Intel(R) C600-A chipset. Matrix RAID support is provided to allow multiple RAID levels to Revision 1.2 Intel order number G34153-003 35 Functional Architecture Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS be combined on a single set of hard drives, such as RAID 0 and RAID 1 on two disks. Other RAID features include hot-spare support, SMART alerting, and RAID 0 auto replace. 3.3.7 PCI Interface (R) The Intel C600-A chipset PCI interface provides a 33 MHz, Revision 2.3 implementation. The Intel(R) C600-A chipset integrates a PCI arbiter that supports up to four external PCI bus masters in addition to the internal Intel(R) C600-A chipset requests. This allows for combinations of up to four PCI down devices and PCI slots. 3.3.8 Low Pin Count (LPC) Interface (R) The Intel C600-A chipset implements an LPC Interface as described in the LPC 1.1 Specification. The Low Pin Count (LPC) bridge function of the Intel(R) C600-A resides in PCI Device 31: Function 0. In addition to the LPC bridge interface function, D31:F0 contains other functional units including DMA, interrupt controllers, timers, power management, system management, GPIO, and RTC. 3.3.9 Serial Peripheral Interface (SPI) (R) The Intel C600-A chipset implements an SPI Interface as an alternative interface for the BIOS flash device. The SPI flash is required to support Gigabit Ethernet and Intel(R) Active Management Technology. The Intel(R) C600-A chipset supports up to two SPI flash devices with speeds up to 50 MHz. 3.3.10 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller) The DMA controller incorporates the logic of two 82C37 DMA controllers, with seven independently programmable channels. The Intel(R) C600-A chipset supports LPC DMA through the Intel(R) C600-A chipset's DMA controller. The timer/counter block contains three counters that are equivalent in function to those found in one 82C54 programmable interval timer. These three counters are combined to provide the system timer function, and speaker tone. The Intel(R) C600-A chipset provides an ISA-Compatible Programmable Interrupt Controller (PIC) that incorporates the functionality of two 82C59 interrupt controllers. In addition, the Intel(R) C600-A chipset supports a serial interrupt scheme. All of the registers in these modules can be read and restored. This is required to save and restore system state after power has been removed and restored to the platform. 3.3.11 Advanced Programmable Interrupt Controller (APIC) In addition to the standard ISA compatible Programmable Interrupt controller (PIC) described in the previous section, the Intel(R) C600-A incorporates the Advanced Programmable Interrupt Controller (APIC). 3.3.12 Universal Serial Bus (USB) Controllers (R) The Intel C600-A chipset has up to two Enhanced Host Controller Interface (EHCI) host controllers that support USB high-speed signaling. High-speed USB 2.0 allows data transfers up to 480 Mb/s which is 40 times faster than full-speed USB. The Intel(R) C600-A chipset supports up to fourteen USB 2.0 ports. All fourteen ports are high-speed, full-speed, and low-speed capable. 3.3.13 Gigabit Ethernet Controller The Gigabit Ethernet Controller provides a system interface using a PCI function. The controller provides a full memory-mapped or IO mapped interface along with a 64 bit address master support for systems using more than 4 GB of physical memory and DMA (Direct Memory Addressing) mechanisms for high performance data transfers. Its bus master capabilities enable the component to process high-level 36 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Functional Architecture commands and perform multiple operations; this lowers processor utilization by off-loading communication tasks from the processor. Two large configurable transmit and receive FIFOs (up to 20 KB each) help prevent data underruns and overruns while waiting for bus accesses. This enables the integrated LAN controller to transmit data with minimum interframe spacing (IFS). The LAN controller can operate at multiple speeds (10/100/1000 MB/s) and in either full duplex or half duplex mode. In full duplex mode the LAN controller adheres with the IEEE 802.3x Flow Control Specification. Half duplex performance is enhanced by a proprietary collision reduction mechanism. 3.3.14 RTC (R) The Intel C600-A chipset contains a real-time clock with 256 bytes of battery-backed RAM. The real-time clock performs two key functions: keeping track of the time of day and storing system data. The RTC operates on a 32.768 KHz crystal and a 3 V battery. 3.3.15 GPIO Various general purpose inputs and outputs are provided for custom system design. The number of inputs and outputs varies depending on the Intel(R) C600-A chipset configuration. 3.3.16 Enhanced Power Management (R) The Intel C600-A chipset's power management functions include enhanced clock control and various low-power (suspend) states (for example, Suspend-to-RAM and Suspend-to-Disk). A hardware-based thermal management circuit permits software-independent entrance to low-power states. The Intel(R) C600A chipset contains full support for the Advanced Configuration and Power Interface (ACPI) Specification, Revision 4.0a. 3.3.17 Manageability In addition to Intel AMT the Intel(R) C600-A chipset integrates several functions designed to manage the system and lower the total cost of ownership (TCO) of the system. These system management functions are designed to report errors, diagnose the system, and recover from system lockups without the aid of an external microcontroller. 3.3.18 System Management Bus (SMBus* 2.0) (R) The Intel C600-A chipset contains a SMBus* Host interface that allows the processor to communicate with SMBus* slaves. This interface is compatible with most I2C devices. Special I2C commands are implemented. The Intel(R) C600-A chipset's SMBus* host controller provides a mechanism for the processor to initiate communications with SMBus* peripherals (slaves). Also, the Intel(R) C600-A chipset supports slave functionality, including the Host Notify protocol. Hence, the host controller supports eight command protocols of the SMBus* interface (see System Management Bus (SMBus*) Specification, Version 2.0): Quick Command, Send Byte, Receive Byte, Write Byte/Word, Read Byte/Word, Process Call, Block Read/Write, and Host Notify. The Intel(R) C600-A chipset's SMBus* also implements hardware-based Packet Error Checking for data robustness and the Address Resolution Protocol (ARP) to dynamically provide address to all SMBus* devices. 3.3.19 Integrated NVSRAM controller (R) The Intel C600-A chipset has an integrated NVSRAM controller that supports up to 32KB external device. The host processor can read and write data to the NVSRAM component. Revision 1.2 Intel order number G34153-003 37 Functional Architecture 3.3.20 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Virtualization Technology for Directed I/O (Intel(R)VT-d) (R) The Intel C600-A chipset provides hardware support for implementation of Intel(R) Virtualization Technology with Directed I/O (Intel(R) VT-d). Intel VT-d consists of technology components that support the virtualization of platforms based on Intel(R) Architecture Processors. Intel VT-d Technology enables multiple operating systems and applications to run in independent partitions. A partition behaves like a virtual machine (VM) and provides isolation and protection across partitions. Each partition is allocated its own subset of host physical memory. 3.3.21 JTAG Boundary-Scan (R) The Intel C600-A chipset adds the industry standard JTAG interface and enables Boundary-Scan in place of the XOR chains used in previous generations of chipsets. Boundary-Scan can be used to ensure device connectivity during the board manufacturing process. The JTAG interface allows system manufacturers to improve efficiency by using industry available tools to test the Intel(R) C600-A chipset on an assembled board. Since JTAG is a serial interface, it eliminates the need to create probe points for every pin in an XOR chain. This eases pin breakout and trace routing and simplifies the interface between the system and a bed-of-nails tester. 3.3.22 KVM/Serial Over Lan (SOL) Function These functions support redirection of keyboard, mouse, and text screen to a terminal window on a remote console. The keyboard, mouse, and text redirection enables the control of the client machine through the network. Text, mouse, and keyboard redirection allows the remote machine to control and configure the client by entering BIOS setup. The KVM/SOL function emulates a standard PCI serial port and redirects the data from the serial port to the management console using LAN. KVM has additional requirements of internal graphics and SOL may be used when KVM is not supported. 3.3.23 On-board SAS/SATA Support and Options The Intel C600 chipset provides storage support by two integrated controllers: AHCI and SCU. By default the server board will support up to 10 SATA ports: Two white 6Gb/sec SATA ports from the AHCI controller labeled as "SATA_0" and "SATA_1" and two MINISAS 3Gb/sec SATA/SAS ports routed from the SCU controller labeled as "SCU0 (PORT0-3) and "SCU1(PORT4-7). (R) The SCU Port can be configured with the two embedded software RAID options: Intel(R) Embedded Server RAID Technology 2 (ESRT2) based on LSI* MegaRAID SW RAID technology supporting RAID levels 0,1, and 10. (R) Intel Rapid Storage Technology (RSTe) supporting RAID levels 0, 1, 5, and 10. 3.3.23.1 Intel(R)Embedded Server RAID Technology 2 (ESRT2) Features of the embedded software RAID option Intel(R) Embedded Server RAID Technology 2 (ESRT2) include the following: Based on LSI* MegaRAID Software Stack Software RAID with system providing memory and CPU utilization Supported RAID Levels - 0,1,5,10 4 and 8 Port SATA RAID 5 support provided with appropriate Intel(R) RAID C600 Upgrade Key 4 and 8 Port SAS RAID 5 support provided with appropriate Intel(R) RAID C600 Upgrade Key Maximum drive support = 8 Open Source Compliance = Binary Driver (includes Partial Source files) or Open Source 38 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Functional Architecture using MDRAID layer in Linux. OS Support = Windows 7*, Windows 2008*, Windows 2003*, RHEL*, SLES, other Linux* variants using partial source builds. Utilities = Windows* GUI and CLI, Linux GUI and CLI, DOS CLI, and EFI CLI 3.3.23.2 Intel(R)Rapid Storage Technology (RSTe) Features of the embedded software RAID option Intel(R) Rapid Storage Technology (RSTe) include the following: Software RAID with system providing memory and CPU utilization Supported RAID Levels - 0,1,5,10 o 4 Port SATA RAID 5 available standard (no option key required) o 8 Port SATA RAID 5 support provided with appropriate Intel(R) RAID C600 Upgrade Key o No SAS RAID 5 support Maximum drive support = 32 (in arrays with 8 port SAS), 16 (in arrays with 4 port SAS), 128 (JBOD) Open Source Compliance = Yes (uses MDRAID) OS Support = Windows 7*, Windows 2008*, Windows 2003*, RHEL* 6.2 and later, SLES* 11 w/SP2 and later, VMWare* 5.x. Utilities = Windows* GUI and CLI, Linux CLI, DOS CLI, and EFI CLI Uses Matrix Storage Manager for Windows* MDRAID supported in Linux* (does not require a driver) Note: No boot drive support to targets attached through SAS expander card 3.4 PCI Subsystem The primary I/O buses for the Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR are PCI Express* Gen3 with six independent PCI bus segments. The following tables list the characteristics of the PCI bus segments. Table 8. Intel(R) Server Board S2600IP/Workstation Board W2600CR PCI Bus Segment Characteristics Voltage 3.3 V Revision 1.2 x16 Width Speed 32 GB/S Type PCI Express* Gen3 PCI I/O Card Slots X16 PCI Express* Gen3 throughput to Slot1 (x16 mechanically) 3.3 V X8 or none (with mux) 16 GB/S or none PCI Express* Gen3 x8 PCI Express* Gen3 throughput to Slot 2 (x8 mechanically) 3.3 V x16 or x8(with mux) 32 GB/S or 16 GB/S PCI Express* Gen3 x16 PCI Express* Gen3 throughput to Slot 3 (x16 mechanically) Intel order number G34153-003 39 Functional Architecture 3.5 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 3.3 V X8 or none (with mux) 16 GB/S or none PCI Express* Gen3 x8 PCI Express* Gen3 throughput to Slot 4 (x8 mechanically, NonPersistent) 3.3 V x16 or x8(with mux) 32 GB/S or 16 GB/S PCI Express* Gen3 X16 PCI Express* Gen3 throughput to Slot 5 (x16 mechanically, NonPersistent) 3.3 V X8 or none (with mux) 16 GB/S or none PCI Express* Gen3 x8 PCI Express* Gen3 throughput to Slot 6 (x8 mechanically, NonPersistent) 3.3 V x16 or x8(with mux) 32 GB/S or 16 GB/S PCI Express* Gen3 X16 PCI Express* Gen3 throughput to Slot 7 (x16 mechanically, NonPersistent) 3.3 V X4 4 GB/S PCI Express* Gen2 X4 PCI Express* Gen2 throughput to Slot 8 (x8 mechanically, NonPersistent) Network Interface Controller The Intel(R) Server Board S2600IP and Workstation Board S2600CR has a Intel(R) Ethernet Controller I350 GbE Controller. The controller supports PCI Express* PCIe v2.0 (5GT/s and 2.5GT/s). The controller enables four-port or two-port 1000BASE-T implementations using integrated PHY's. The controller supports VMDq, SR-IOV, EEE, and DMA Coalescing. 3.5.1 Network Interface Network connectivity is provided by means of an onboard Intel(R) Ethernet Controller 1350-AM4 providing up to four 10/100/1000 Mb Ethernet ports. On the Intel(R) Server Board S2600IP, four external 10/100/1000 Mb RJ45 Ethernet ports are provided. On the Intel(R) Workstation Board W2600CR, two external 10/100/1000 Mb RJ45 Ethernet ports are provided. Each Ethernet port drives two LEDs located on each network interface connector. The LED at the right of the connector is the link/activity LED and indicates network connection when on, and transmit/receive activity when blinking. The LED at the left of the connector indicates link speed as defined in the following table. 40 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS LED Color Green/Amber (Right) Green (Left) LED State Functional Architecture NIC State Off 10 Mbps Amber 100 Mbps Green 1000 Mbps On Active Connection Blinking Transmit/Receive activity Figure 20. External RJ45 NIC Port LED Definition 3.6 I/O Module Support (not avaiable for Intel(R) Server Board S2600IP4L and Intel(R) Workstation Board W2600CR2L) To broaden the standard on-board feature set, the server board supports the option of adding a single I/O module providing external ports for a variety of networking interfaces. The I/O module attaches to a high density 80-pin connector on the server board labeled "IO_Module". Supported I/O modules include: Revision 1.2 Intel order number G34153-003 41 Functional Architecture Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Product Code and iPN AXX10GBNIAIOM MM# 917905 Description Dual SFP+ port 10GbE IO Module based on Intel(R) 82599 10GbE Ethernet Controller AXX10GBTWLIOM MM# 917907 Dual RJ45 Port, 10GBASE-T IO Module, based on Intel(R) I350 Ethernet chipset AXX1FDRIBIOM MM# 918607 Single Port, FDR speed Infiniband* module, with QSFP connector. AXX4P1GBPWLIOM MM# 917911 Quad Port 1GbE 1o Module based on Intel(R) Ethernet Controller I350 AXXIOMKIT MM# 920852 I/O Module Cable and Brackets Figure 21. Supported I/O Module Options Notes: 1. I/O Module cable and Brackets accessory is necessary to support I/O module on Intel(R) Server Board S2600IP. 2. IOM connector only supports PCIe Gen1 Speed 3.7 SAS ROC Module Support The system provides support for Intel(R) Integrated RAID mezzanine modules that utilize a high density 80-pin connector (labeled "SAS_MOD") on the server board. 42 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Functional Architecture Features of this option include: Does not utilize a PCIe slot SKU options to support full or entry level hardware RAID 4 or 8 port and SAS/SATA or SATA -only ROC options SKU options to support 512MB or 1GB embedded memory Intel designed flash + optional support for super-cap backup (Maintenance Free Back Up) or improved Lithium Polymer battery Table 9. Supported Intel(R) Integrated RAID Modules External Name (R) Description Product Code Intel Integrated RAID Module RMS25CB080 8 Port SAS-2.1, Full HW RAID, 1GB, Mezz Slot RAID Levels 0,1,10, 5, 50, 6, 60 RMS25CB080 Intel(R) Integrated RAID Module RMS25CB040 4 Port SAS-2.1, Full HW RAID, 1GB, Mezz Slot RAID Levels 0,1,10, 5, 50, 6, 60 RMS25CB040 Intel(R) Integrated RAID Module RMT3CB080 8 Port SATA-3, Full HW RAID, 512MB, Mezz Slot RAID Levels 0,1,10, 5, 50, 6, 60 RMT3CB080 Intel(R) Integrated RAID Module RMS25KB080 8 Port SAS-2.1, Entry-level HW RAID, Mezz Slot RAID Levels 0,1,1E RMS25KB080 Intel(R) Integrated RAID Module RMS25KB040 4 Port SAS-2.1, Entry-level HW RAID, Mezz Slot RAID Levels 0,1,1E RMS25KB040 For additional product information, please refer the following Intel(R) document: Intel(R) Integrated RAID Module RMS25PB080, RMS25PB040, RMS25CB080, and RMS25CB040 Hardware User's Guide - Intel Order Number G37519-003. 3.8 HD Audio Support (Intel(R) Workstation Board W2600CR Only) The Intel(R) Workstation Board W2600CR support 7.1 HD Audio through the High Definition Audio Codec Realtek* ALC889. The ALC889 provides ten DAC channels that simultaneously support 7.1 sound playback, plus two channels of independent stereo sound output (multiple streaming) through the front panel stereo outputs. Also supports two channels of S/PDIF In/Out (W2600CR only supports 1 S/PDIF Out port) and two channels of Microphone In (Front/Rear). The ALC889 is driven by the Intel(R) HD Audio Interface (Azalia) from Intel(R) C600-A chipset. Revision 1.2 Intel order number G34153-003 43 Functional Architecture Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Table 10. Standard Speaker Channels Channel name Identifier 1.0 Mono 2.0 Stereo 5.1 Surround 7.1 Surround Front Left SPEAKER_FRONT_LEFT No Yes Yes Yes Front Right SPEAKER_FRONT_RIGHT No Yes Yes Yes Front Center SPEAKER_FRONT_CENTER Yes No Yes Yes Low Frequency (Subwoofer) SPEAKER_LOW_FREQUENCY No No Yes Yes Back Left SPEAKER_BACK_LEFT No No Yes Yes Back Right SPEAKER_BACK_RIGHT No No Yes Yes Side Left SPEAKER_SIDE_LEFT No No No Yes Side Right SPEAKER_SIDE_RIGHT No No No Yes 3.9 USB3.0 Support (Intel(R) Workstation Board W2600CR Only) The Intel(R) Workstation Board W2600CR supports two USB3.0 SuperSpeed* ports, which is required as a standard Workstation feature. The TI 2 port USB3.0 discrete host controller TUSB7320 is used to meet this requirement. The TUSB7320 USB3.0 host controller complies with Universal Serial Bus 3.0 Specification and Intel's eXtensible Host Controller Interface (xHCI). Figure 22. USB3.0 Discrete Host Controller Block Diagram 44 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Functional Architecture 3.10 IEEE1394b Support (Intel(R) Workstation Board W2600CR Only) Intel(R) Workstation Board W2600CR offers one front panel IEEE 1394b port from a discrete controller (Texas Instruments XIO2221).The XIO2221 uses a PCIe x1 Gen 1 upstream interface from Intel(R) C600-A chipset. When connected to 1394b compliant devices, the XIO2221 can transfer data at speeds of up to 800 Mbps. The Intel(R) Workstation Board W2600CR includes an internal 1394b connector that allows for a front panel 1394b cable attach. Figure 23. IEEE 1394b Discrete Host Controller Block Diagram Revision 1.2 Intel order number G34153-003 45 Platform Management Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 4. Platform Management Overview 4.1 Server Management Function Architecture 4.1.1 Feature Support 4.1.1.1 IPMI 2.0 Features The IPMI 2.0 features are as follows: 1. Baseboard management controller (BMC) 2. IPMI Watchdog timer 3. Messaging support, including command bridging and user/session support 4. Chassis device functionality, including power/reset control and BIOS boot flags support 5. Event receiver device: The BMC receives and processes events from other platform subsystems. 6. Field Replaceable Unit (FRU) inventory device functionality: The BMC supports access to system FRU devices using IPMI FRU commands. 7. System Event Log (SEL) device functionality: The BMC supports and provides access to a SEL. 8. Sensor Data Record (SDR) repository device functionality: The BMC supports storage and access of system SDRs. 9. Sensor device and sensor scanning/monitoring: The BMC provides IPMI management of sensors. It polls sensors to monitor and report system health. 10. IPMI interfaces 11. Host interfaces include system management software (SMS) with receive message queue support, and server management mode (SMM) 12. IPMB interface 13. LAN interface that supports the IPMI-over-LAN protocol Remote Management Control Protocol (RMCP, RMCP+) 14. Serial-over-LAN (SOL) 15. ACPI state synchronization: The BMC tracks ACPI state changes that are provided by the BIOS. 16. BMC self test: The BMC performs initialization and run-time self-tests and makes results available to external entities. See also the Intelligent Platform Management Interface Specification Second Generation, Version 2.0. 4.1.1.2 Non IPMI features The BMC supports the following non-IPMI features. This list does not preclude support for future enhancements or additions. 46 In-circuit BMC firmware update Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality. Chassis intrusion detection (dependent on platform support) Basic fan control using Control version 2 SDRs Fan redundancy monitoring and support Power supply redundancy monitoring and support Hot-swap fan support Acoustic management: Support for multiple fan profiles Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Platform Management Overview Signal testing support: The BMC provides test commands for setting and getting platform signal states. The BMC generates diagnostic beep codes for fault conditions. System GUID storage and retrieval Front panel management: The BMC controls the system status LED and chassis ID LED. It supports secure lockout of certain front panel functionality and monitors button presses. The chassis ID LED is turned on using a front panel button or a command. Power state retention Power fault analysis Intel(R) Light-Guided Diagnostics Power unit management: Support for power unit sensor. The BMC handles power-good dropout conditions. DIMM temperature monitoring: New sensors and improved acoustic management using closedloop fan control algorithm taking into account DIMM temperature readings. Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported on embedded NICs). Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported on embedded NICs). Platform environment control interface (PECI) thermal management support E-mail alerting Embedded web server Integrated KVM. Integrated Remote Media Redirection Lightweight Directory Access Protocol (LDAP) support Intel(R) Intelligent Power Node Manager support 4.1.1.3 New Manageability Features (R) Intel S1400/S1600/S2400/S2600 Server Platforms offer a number of changes and additions to the manageability features that are supported on the previous generation of servers. The following is a list of the more significant changes that are common to this generation Integrated BMC based Intel(R) Server boards: Sensor and SEL logging additions/enhancements (for example, additional thermal monitoring capability) SEL Severity Tracking and the Extended SEL Embedded platform debug feature which allows capture of detailed data for later analysis. Provisioning and inventory enhancements: o Inventory data/system information export (partial SMBIOS table) Enhancements to fan speed control. DCMI 1.1 compliance (product-specific). Support for embedded web server UI in Basic Manageability feature set. Enhancements to embedded web server o o o Revision 1.2 Human-readable SEL Additional system configurability Additional system monitoring capability Intel order number G34153-003 47 Platform Management Overview o Enhanced on-line help Enhancements to KVM redirection o Support for higher resolution Support for EU Lot6 compliance Management support for PMBus* rev1.2 compliant power supplies BMC Data Repository (Managed Data Region Feature) Local Control Display Panel System Airflow Monitoring Exit Air Temperature Monitoring Ethernet Controller Thermal Monitoring Global Aggregate Temperature Margin Sensor Memory Thermal Management Power Supply Fan Sensors Energy Star Server Support Smart Ride Through (SmaRT)/ Closed Loop System Throttling (CLST) Power Supply Cold Redundancy Power Supply FW Update Power Supply Compatibility Check BMC FW reliability enhancements: o o 4.1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Redundant BMC boot blocks to avoid possibility of a corrupted boot block resulting in a scenario that prevents a user from updating the BMC. BMC System Management Health Monitoring Basic and Advanced Features The bellowing table lists basic and advanced feature support. Individual features may vary by platform. See the appropriate Platform Specific EPS addendum for more information. Table 11. Basic and Advanced Features Feature IPMI 2.0 Feature Support 48 Basic X Advanced X In-circuit BMC Firmware Update X X FRB 2 X X Chassis Intrusion Detection X X Fan Redundancy Monitoring X X Hot-Swap Fan Support X X Acoustic Management X X Diagnostic Beep Code Support X X Power State Retention X X ARP/DHCP Support X X Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Feature PECI Thermal Management Support Platform Management Overview Basic X Advanced X E-mail Alerting X X Embedded Web Server X X SSH Support X X Integrated KVM X Integrated Remote Media Redirection X Lightweight Directory Access Protocol (LDAP) X X Intel Intelligent Power Node Manager Support X X SMASH CLP X X (R) 4.1.3 Integrated BMC Hardware: Emulex* Pilot III 4.1.3.1 Emulex* Pilot III Baseboard Management Controller Functionality The Integrated BMC is provided by an embedded ARM9 controller and associated peripheral functionality that is required for IPMI-based server management. Firmware usage of these hardware features is platform dependent. The following is a summary of the Integrated BMC management hardware features that comprise the BMC: 400MHz 32-bit ARM9 processor with memory management unit (MMU) Two independent10/100/1000 Ethernet Controllers with Reduced Media Independent Interface (RMII)/ Reduced Gigabit Media Independent Interface (RGMII) support DDR2/3 16-bit interface with up to 800 MHz operation 16 10-bit ADCs Sixteen fan tachometers Eight Pulse Width Modulators (PWM) Chassis intrusion logic JTAG Master Eight I2C interfaces with master-slave and SMBus* timeout support. All interfaces are SMBus* 2.0 compliant. Parallel general-purpose I/O Ports (16 direct, 32 shared) Serial general-purpose I/O Ports (80 in and 80 out) Three UARTs Platform Environmental Control Interface (PECI) Six general-purpose timers Interrupt controller Multiple Serial Peripheral Interface (SPI) flash interfaces NAND/Memory interface Sixteen mailbox registers for communication between the BMC and host LPC ROM interface BMC watchdog timer capability SD/MMC card controller with DMA support LED support with programmable blink rate controls on GPIOs Port 80h snooping capability Secondary Service Processor (SSP), which provides the HW capability of offloading time critical processing tasks from the main ARM core. Emulex* Pilot III contains an integrated SIO, KVMS subsystem and graphics controller with the following features: Revision 1.2 Intel order number G34153-003 49 Platform Management Overview 4.1.3.1.1 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Super I/O (SIO) The BMC integrates a super I/O module with the following features: Keyboard Style/BT interface for BMC support Two Fully Functional Serial Ports, compatible with the 16C550 Serial IRQ Support Up to 16 Shared GPIO available for host processor Programmable Wake-up Event Support Plug and Play Register Set Power Supply Control 4.1.3.1.2 Graphics Controller The graphics controller provides the following features: Integrated Graphics Core with 2D Hardware accelerator High speed Integrated 24-bit RAMDAC DDR-2/3 memory interface with 16Mbytes of memory allocated and reported for graphics memory. 4.1.3.1.3 Remote Keyboard, Video, Mouse, and Storage (KVMS ) The Integrated BMC contains a remote KVMS subsystem with the following features: 50 USB 2.0 interface for Keyboard, Mouse and Remote storage such as CD/DVD ROM and floppy USB 1.1/USB 2.0 interface for PS2 to USB bridging, remote Keyboard and Mouse Hardware Based Video Compression and Redirection Logic Supports both text and Graphics redirection Hardware assisted Video redirection using the Frame Processing Engine Direct interface to the Integrated Graphics Controller registers and Frame buffer Hardware-based encryption engine Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Platform Management Overview Figure 24. Integrated BMC Hardware 4.2 Server Management Functional Specifications 4.2.1 BMC Internal Timestamp Clock The BMC maintains an internal timestamp clock that is used by various BMC subsystems, for example, time stamping SEL entries. As part of BMC initialization after AC power is applied or the BMC is reset, the BMC initializes this internal clock to the value retrieved from the SSB component's RTC from a SMBus* slave read operation. This is the system RTC and is on the battery power well so it maintains the current time even when there is no AC supplied to the system. 4.2.1.1 System Clock Synchronization The BIOS must send the Set SEL Time command with the current system time to the BMC during system Power-on Self Test (POST). Synchronization during very early POST is preferred, so that any SEL entries recorded during system boot can be accurately time stamped. Additionally, during sleep state transitions other than S0 the BIOS will synchronize the time. If the time is modified through an OS interface, then the BMC's time is not synchronized until the next system reboot. Revision 1.2 Intel order number G34153-003 51 Platform Management Overview 4.2.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS System Event Log (SEL) The BMC implements the system event log as specified in the Intelligent Platform Management Interface Specification, Version 2.0. The SEL is accessible regardless of the system power state through the BMC's in-band and out-of-band interfaces. The BMC allocates 95231 bytes (approximately 93 KB) of non-volatile storage space to store system events. The SEL timestamps may not be in order. Up to 3,639 SEL records can be stored at a time. Any command that results in an overflow of the SEL beyond the allocated space is rejected with an "Out of Space" IPMI completion code (C4h). 4.2.3 Sensor Data Record (SDR) Repository The BMC implements the sensor data record (SDR) repository as specified in the Intelligent Platform Management Interface Specification, Version 2.0. The SDR is accessible through the BMC's in-band and out-of-band interfaces regardless of the system power state The BMC allocates 65,519 bytes of nonvolatile storage space for the SDR. 4.2.4 Field Replaceable Unit (FRU) Inventory Device The BMC implements the interface for logical FRU inventory devices as specified in the Intelligent Platform Management Interface Specification, Version 2.0. This functionality provides commands used for accessing and managing the FRU inventory information. These commands can be delivered through all interfaces. The BMC provides FRU device command access to its own FRU device and to the FRU devices throughout the server. The FRU device ID mapping is defined in the Platform Specific Information. The BMC controls the mapping of the FRU device ID to the physical device. 4.2.5 BMC Beep Codes The BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each time the problem is discovered (for example, on each power-up attempt), but are not sounded continuously. Common supported codes are listed in below Table Additional platform-specific beep codes can be found in the appropriate Platform Specific Information. Each digit in the code is represented by a sequence of beeps whose count is equal to the digit. Table 12. BMC Beep Codes 52 Code 1-5-2-1 Reason for Beep No CPUs installed or first CPU socket is empty. Associated Sensors CPU Missing Sensor 1-5-2-4 MSID Mismatch. MSID Mismatch Sensor. 1-5-4-2 Power fault: DC power is unexpectedly lost (power good dropout). Power unit - power unit failure offset. 1-5-4-4 Power control fault (power good assertion timeout). Power unit - soft power control failure offset. 1-5-1-2 VR Watchdog Timer sensor assertion VR Watchdog Timer Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Code 1-5-1-4 4.2.6 Reason for Beep The system does not power on or unexpectedly powers off and a power supply unit (PSU) is present that is an incompatible model with one or more other PSUs in the system Platform Management Overview Associated Sensors PS Status Diagnostic Interrupt (NMI) Button The BMC generates an NMI pulse under certain conditions. The BMC-generated NMI pulse duration is at least 30 ms. Once an NMI has been generated by the BMC, the BMC does not generate another NMI until the system has been reset or powered down. The following actions cause the BMC to generate an NMI pulse: 1. Receiving a Chassis Control command to pulse the diagnostic interrupt. This command does not cause an event to be logged in the SEL. 2. Watchdog timer pre-timeout expiration with NMI/diagnostic interrupt pre-timeout action enabled. The following table shows the behavior regarding NMI signal generation and event logging by the BMC. Table 13. NMI Signal Generation and Event Logging Causal Event Signal Generation NMI Front Panel Diag Interrupt Sensor Event Logging Support Chassis Control command (pulse diagnostic interrupt) X - Front panel diagnostic interrupt button pressed X X Watchdog Timer pre-timeout expiration with NMI/diagnostic interrupt action X X 4.2.7 BMC Watchdog The BMC FW is increasingly called upon to perform system functions that are time-critical in that failure to provide these functions in a timely manner can result in system or component damage. Intel(R) S1400/S1600/S2400/S2600 Server Platforms introduce a BMC watchdog feature to provide a safe-guard against this scenario by providing an automatic recovery mechanism. It also can provide automatic recovery of functionality that has failed due to a fatal FW defect triggered by a rare sequence of events or a BMC hang due to some type of HW glitch (for example, power). This feature is comprised of a set of capabilities whose purpose is to detect misbehaving subsections of BMC firmware, the BMC CPU itself, or HW subsystems of the BMC component, and to take appropriate action to restore proper operation. The action taken is dependent on the nature of the detected failure and may result in a restart of the BMC CPU, one or more BMC HW subsystems, or a restart of malfunctioning FW subsystems. The BMC watchdog feature will only allow up to three resets of the BMC CPU (such as HW reset) or entire FW stack (such as a SW reset) before giving up and remaining in the uBOOT code. This count is cleared upon cycling of power to the BMC or upon continuous operation of the BMC without a watchdog-generated reset occurring for a period of > 30 minutes. The BMC FW logs a SEL event indicating that a watchdog-generated BMC reset (either soft or hard reset) has occurred. This event may be logged after the actual reset has occurred. Refer sensor Revision 1.2 Intel order number G34153-003 53 Platform Management Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS section for details for the related sensor definition. The BMC will also indicate a degraded system status on the Front Panel Status LED after an BMC HW reset or FW stack reset. This state (which follows the state of the associated sensor) will be cleared upon system reset or (AC or DC) power cycle. Note: A reset of the BMC may result in the following system degradations that will require a system reset or power cycle to correct: 1. Timeout value for the rotation period can be set using this parameter; potentially incorrect ACPI Power State reported by the BMC. 2. Reversion of temporary test modes for the BMC (for example, as set through Set SM Signal command) back to normal operational modes. 3. FP status LED and DIMM fault LEDs may not reflect BIOS detected errors. 4.3 4.3.1 Sensor Monitoring Overview The BMC monitors system hardware and reports system health. The information gathered from physical sensors is translated into IPMI sensors as part of the "IPMI Sensor Model". The BMC also reports various system state changes by maintaining virtual sensors that are not specifically tied to physical hardware. This section describes the BMC sensors as well as describing how specific sensor types are modeled. Unless otherwise specified, the term "sensor" refers to the IPMI sensor-model definition of a sensor. 4.3.2 Core Sensor List for EPSD Platforms Based on Intel(R)Xeon(R)Processor E5 4600/2600/2400/1600/1400 Product Families Specific server boards may only implement a sub-set of sensors and/or may include additional sensors. The system-specific details of supported sensors and events are described in the Appendix of this document. The actual sensor name associated with a sensor number may vary between server boards or systems. Sensor Type Codes Sensor table given below lists the sensor identification numbers and information regarding the sensor type, name, supported thresholds, assertion and de-assertion information, and a brief description of the sensor purpose. Refer to the Intelligent Platform Management Interface Specification, Version 2.0 for sensor and event/reading-type table information. Sensor Type The sensor type references the values in the Sensor Type Codes table in the Intelligent Platform Management Interface Specification Second Generation v2.0. It provides a context to interpret the sensor. Event/Reading Type The event/reading type references values from the Event/Reading Type Code Ranges and the Generic Event/Reading Type Code tables in the Intelligent Platform Management Interface Specification Second Generation v2.0. Digital sensors are specific type of discrete sensors that only have two states. Event Thresholds/Triggers The following event thresholds are supported for threshold type sensors: - [u,l][nr,c,nc] upper non-recoverable, upper critical, upper non-critical, lower non-recoverable, lower critical, lower non-critical uc, lc upper critical, lower critical Event triggers are supported event-generating offsets for discrete type sensors. The offsets can be found in the Generic Event/Reading Type Code or Sensor Type Code tables in the Intelligent 54 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Platform Management Overview Platform Management Interface Specification Second Generation, Version 2.0, depending on whether the sensor event/reading type is generic or a sensor-specific response. Assertion/Deassertion Assertion and de-assertion indicators reveal the type of events this sensor generates: - As: Assertion - De: De-assertion Readable Value/Offsets - Readable value indicates the type of value returned for threshold and other nondiscrete type sensors. - Readable offsets indicate the offsets for discrete sensors that are readable by means of the Get Sensor Reading command. Unless otherwise indicated, event triggers are readable. Readable offsets consist of the reading type offsets that do not generate events. Event Data Event data is the data that is included in an event message generated by the associated sensor. For threshold-based sensors, these abbreviations are used: - R: Reading value - T: Threshold value Rearm Sensors The rearm is a request for the event status for a sensor to be rechecked and updated upon a transition between good and bad states. Rearming the sensors can be done manually or automatically. This column indicates the type supported by the sensor. The following abbreviations are used in the comment column to describe a sensor: - A: Auto-rearm - M: Manual rearm - I: Rearm by init agent Default Hysteresis The hysteresis setting applies to all thresholds of the sensor. This column provides the count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis). Criticality Criticality is a classification of the severity and nature of the condition. It also controls the behavior of the front panel status LED. Standby Some sensors operate on standby power. These sensors may be accessed and/or generate events when the main (system) power is off, but AC power is present. 4.3.3 BMC System Management Health Monitoring The BMC tracks the health of each of its IPMI sensors and report failures by providing a "BMC FW Health" sensor of the IPMI 2.0 sensor type Management Subsystem Health with support for the Sensor Failure offset. Only assertions should be logged into the SEL for the Sensor Failure offset. The sensor number of the failed sensor is provided in event data byte 2, as per the IPMI 2.0 Specification. The BMC Firmware Health sensor asserts for any sensor when 10 consecutive sensor errors are read. These are not standard sensor events (that is, threshold crossings or discrete assertions). These are BMC Hardware Access Layer (HAL) errors like I2C NAKs or internal errors while attempting to read a register. If a successful sensor read is completed, the counter resets to zero. IPMI Sensor Characteristics Revision 1.2 Intel order number G34153-003 55 Platform Management Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 1. Event reading type code: 6Fh (Sensor specific) 2. Sensor type code: 28h (Management Subsystem Health) 3. Rearm type: Auto If this sensor is implemented, then the following sensor-specific offsets are supported. Table 14. Supported BMC FW Health Sensor Offsets Offset 04h 4.3.4 Description Sensor failure Event Logging Assertion and deassertion Processor Sensors The BMC provides IPMI sensors for processors and associated components, such as voltage regulators and fans. The sensors are implemented on a per-processor basis. Table 15. Processor Sensors Sensor Name Processor Status Per-Processor Socket Yes Processor presence and fault state Digital Thermal Sensor Yes Relative temperature reading by means of PECI Processor VRD Over-Temperature Indication Yes Discrete sensor that indicates a processor VRD has crossed an upper operating temperature threshold Processor Voltage Yes Threshold sensor that indicates a processor power-good state Processor Thermal Control (Prochot) Yes Percentage of time a processor is throttling due to thermal conditions 4.3.4.1 Description Processor Status Sensors The BMC provides an IPMI sensor of type processor for monitoring status information for each processor slot. If an event state (sensor offset) has been asserted, it remains asserted until one of the following happens: 1. A Rearm Sensor Events command is executed for the processor status sensor. 2. AC or DC power cycle, system reset, or system boot occurs. The BMC provides system status indication to the front panel LEDs for processor fault conditions shown in Table 16. CPU Presence status is not saved across AC power cycles and therefore will not generate a de-assertion after cycling AC power. Table 16. Processor Status Sensor Implementation 56 Offset 0 Internal error (IERR) Processor Status Detected By Not Supported 1 Thermal trip BMC 2 FRB1/BIST failure Not Supported 3 FRB2/Hang in POST failure BIOS1 4 FRB3/Processor startup/initialization failure (CPU fails to start) Not Supported 5 Configuration error (for DMI) BIOS1 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Platform Management Overview Offset 6 Processor Status SM BIOS uncorrectable CPU-complex error Detected By Not Supported 7 Processor presence detected BMC 8 Processor disabled Not Supported 9 Terminator presence detected Not Supported Note: Fault is not reflected in the processor status sensor. 4.3.4.1.1 Processor Presence Upon BMC initialization, which occurs when AC power is applied or the BMC is reset, the processor presence offset is initialized to the deasserted state and then the BMC checks to see if the processor is present and sets the presence offset accordingly. This state is updated at each DC power-on and at system resets. The net effect of this is that there should be one event logged at BMC startup for processor presence for each installed processor, assuming the SDR is configured to generate the event. No additional events for processor presence are expected unless the sensor is manually re-armed using an IPMI command or a processor is removed or inserted. Note that removal and insertion should only occur when AC power is removed from the system so it is not expected that a SEL entry will be seen for this specific occurrence. 4.3.4.2 Processor Population Fault (CPU Missing) Sensor The BMC supports a Processor Population Fault sensor for monitoring for the condition in which processor slots are not populated as required by the platform HW to allow power-on of the system. At BMC startup, the BMC will check for the fault condition and set the sensor state accordingly. The BMC also checks for this fault condition at each attempt to DC power-on the system. At each DC power-on attempt, a beep code is generated if this fault is detected. Please refer Table 9 (BMC Beep Codes) for beep code details. The following steps are used to correct the fault condition and clear the sensor state: 1. AC power down the server. 2. Install the missing processor into the correct slot. 3. AC power on the server. Refer to the applicable platform BMC EPS as to the details of what population rules must be followed. 4.3.4.3 ERR2 Timeout Monitoring The BMC supports an ERR2 Timeout Sensor (1 per CPU) that asserts if a CPU's ERR2 signal has been asserted for longer than a fixed time period (> 90 seconds). ERR[2] is a processor signal that indicates when the IIO (Integrated IO module in the processor) has a fatal error which could not be communicated to the core to trigger SMI. ERR[2] events are fatal error conditions, where the BIOS and OS will attempt to gracefully handle error, but may not be always do so reliably. A continuously asserted ERR2 signal is an indication that the BIOS cannot service the condition that caused the error. This is usually because that condition prevents the BIOS from running. When an ERR2 timeout occurs, the BMC asserts/deasserts the ERR2 Timeout Sensor, and logs a SEL event for that sensor. The default behavior for BMC core firmware is to initiate a system reset upon detection of an ERR2 timeout. The BIOS setup utility provides an option to disable or enable system reset by the BMC for detection of this condition. IPMI Sensor Characteristics Revision 1.2 Intel order number G34153-003 57 Platform Management Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 1. Event reading type code: 03h (Generic - digital discrete) 2. Sensor type code: 07h (Processor) 3. Rearm type: Auto Table 17. Supported ERR2 Timeout Sensor Offsets Offset 01h 4.3.4.4 Description State asserted Event Logging Assertion and deassertion CATERR Sensor and Market Segment ID (MSID) Mismatch The BMC supports a CATERR sensor for monitoring the system CATERR signal. The CATERR signal is defined as having 3 states; high (no event), pulsed low (possibly fatal may be able to recover), and low (fatal). All processors in a system have their CATERR pins tied together. The pin is used as a communication path to signal a catastrophic system event to all CPUs. The BMC has direct access to this aggregate CATERR signal. The BMC only monitors for the "CATERR held low" condition. A pulsed low condition is ignored by the BMC. If a CATERR-low condition is detected, the BMC logs an error message to the SEL against the CATERR sensor and then queries each CPU to determine if it was due to an MSID mismatch condition. An MSID mismatch occurs if a processor is installed into a system board that has incompatible power capabilities. The MSID mismatch condition is indicated in a processor machine check MSR. If PECI is non-functional (it isn't guaranteed in this situation), then MSID mismatch can't be detected in that case. If the CATERR is due to an MSID mismatch, then the BMC will log an additional SEL log against the MSID Mismatch sensor, light the CPU fault LED, emit a beep code, and let the system hang. Please refer Table 9 (BMC Beep Codes) for beep code details. If no MSID mismatch is detected, then the default action after logging the SEL entry is to reset the system. The BIOS setup utility provides an option to disable or enable system reset by the BMC for detection of this condition. 4.3.4.5 CATERR Sensor The BMC supports a CATERR sensor for monitoring the system CATERR signal. The sensor is rearmed on power-on (AC or DC power on transitions). It is not rearmed on system resets in order to avoid multiple SEL events that could occur due to a potential reset loop if the CATERR keeps recurring, which would be the case if the CATERR was due to an MSID mismatch condition. On EPSD boards, the CATERR signal from each CPU are tied together and routed to the BMC as one signal. When the BMC detects that this aggregate CATERR signal has asserted, it can then go through PECI to query each CPU to determine which one was the source of the error and write an OEM code identifying the CPU slot into an event data byte in the SEL entry. If PECI is non-functional (it isn't guaranteed in this situation), then the OEM code should indicate that the source is unknown. Event data byte 2 and byte 3 for CATERR sensor SEL events ED2 - CATERR type. 0: Unknown 1: CATERR 58 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Platform Management Overview 2: CPU Core Error (not supported on EPSD Platforms Based on Intel(R) Xeon(R) Processor E5 4600/2600/2400/1600 Product Families) 3: MSID Mismatch ED3 - CPU bitmap that causes the system CATERR. [0]: CPU0 [1]: CPU1 [2]: CPU2 [3]: CPU3 IPMI Sensor Characteristics 1. Event reading type code: 03h (Digital discrete) 2. Sensor type code: 07h (Processor) 3. Rearm type: Manual The following sensor-specific offsets are supported: Table 18. Supported CATERR Sensor Offsets Offset 01h 4.3.4.6 Description State asserted Event Logging Assertion and deassertion MSID Mismatch Sensor The BMC supports a MSID Mismatch sensor for monitoring for the fault condition that will occur if there is a power rating incompatibility between a baseboard and an a processor The sensor is rearmed on power-on (AC or DC power on transitions). IPMI Sensor Characteristics 1. Event reading type code: 03h (Digital discrete) 2. Sensor type code: 07h (Processor) 3. Rearm type: Manual The following sensor-specific offsets are supported: Table 19. Support MSID Mismatch Sensor Offsets Offset 01h 4.4 Description State asserted Event Logging Assertion and deassertion Thermal and Acoustic Management The Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR offers multiple thermal and acoustic management features to maintain comprehensive thermal protection as well as intelligent fan speed control. The features can be adjusted in BIOS interface with path BIOS > Advanced > System Acoustic and Performance Configuration. Revision 1.2 Intel order number G34153-003 59 Platform Management Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 4.4.1 Set Throttling Mode Select the most appropriate memory thermal throttling mechanism for memory sub-system from [Auto], [DCLTT], [SCLTT] and [SOLTT]. [Auto] - BIOS automatically detect and identify the appropriate thermal throttling mechanism based on DIMM type, airflow input, DIMM sensor availability. [DCLTT] - Dynamic Closed Loop Thermal Throttling: for the SOD DIMM with system airflow input [SCLTT] - Static Close Loop Thermal Throttling: for the SOD DIMM without system airflow input [SOLTT] - Static Open Loop Thermal Throttling: for the DIMMs without sensor on dimm (SOD) The default setting is [Auto]. 4.4.2 Altitude Select the proper altitude that the system is distributed from [300m or less], [301m-900m], [901m-1500m], [Above 1500m] options. Lower altitude selection can lead to potential thermal risk. And higher altitude selection provides better cooling but with undesired acoustic and fan power consumption. If the altitude is known, higher altitude is recommended in order to provide sufficient cooling. The default setting is [301m - 900m]. 4.4.3 Set Fan Profile [Performance] and [Acoustic] fan profiles are available to select. The Acoustic mode offers best acoustic experience and appropriate cooling capability covering mainstream and majority of the add-in cards. Performance mode is designed to provide sufficient cooling capability covering all kinds of add-in cards on the market. The default setting is [Performance] 4.4.4 Fan PWM Offset This feature is reserved for manual adjustment to the minimum fan speed curves. The valid range is from [0 to 100] which stands for 0% to 100% PWM adding to the minimum fan speed. This feature is valid when Quiet Fan Idle Mode is at Enabled state. The default setting is [0]. 4.4.5 Quiet Fan Idle Mode This feature can be [Enabled] or [Disabled]. If enabled, the fan will either stopped or shift to a lower speed when the aggregate sensor temperatures are satisfied indicating the system is at ideal thermal/light loading conditions. When the aggregate sensor temperatures not satisfied, the fan will shift back to normal control curves. If disabled, the fan will never stopped or shift into lower fan speed whatever the aggregate sensor temperatures are satisfied or not. The default setting is [Disabled] Note: 1. The above features may or may not be in effective depends on the actual thermal characters of a specific system. 2. Refer to System TPS for the board in Intel chassis thermal and acoustic management 3. Refer to Fan Control Whitepaper for the board in third party chassis fan speed control customization. 60 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Platform Management Overview 4.4.6 Thermal Sensor Input for Fan Speed Control The BMC uses various IPMI sensors as inputs to FSC. Some of the sensors are actual physical sensor and some are "virtual" sensors derived from calculation. The following IPMI thermal sensors are used as input to the fan speed control: Front Panel Temperature Sensor1 Baseboard Temperature Sensor2 CPU Margin Sensors3,5,6 DIMM Thermal Margin Sensors3,5 Exit Air Temperature Sensor1, 4, 8 PCH Temperature Sensor4,6 On-board Ethernet Controller Temperature Sensors4, 6 Add-In Intel SAS/IO Module Temperature Sensors4, 6 PSU Thermal Sensor4, 9 CPU VR Temperature Sensors4, 7 DIMM VR Temperature Sensors4, 7 iBMC Temperature Sensor4, 7 Global Aggregate Thermal Margin Sensors3, 8 Note: 1. For fan speed control in Intel chassis 2. For fan speed control in 3rd party chassis 3. Temperature margin from throttling threshold 4. Absolute temperature 5. PECI value 6. On-die sensor 7. On-board sensor 8. Virtual sensor 9. Available only when PSU has PMBus* A simplified model is shown as below which gives a high level concept of the fan speed control structure. Figure 25. High-level Fan Speed Control Process Revision 1.2 Intel order number G34153-003 61 Platform Management Overview 4.4.7 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Power Supply Status\Health Sensors The BMC supports one Power Supply Status sensor for each system power supply module. In order to track problems in which the PSU firmware is not operating to full capacity, an additional case (degraded condition if the PSU firmware is not operating to full capacity) is added to the existing Power Supply Status sensor offset definitions. This is handled by assertion of the "configuration error" offset of the PSU status sensor. These sensors are only supported for systems that use PMBus*-compliant power supplies. IPMI Sensor Characteristics 1. Event reading type code: 6Fh (Sensor Specific) 2. Event sensor type code: 08h (Power Supply) 3. Rearm type: Auto The following sensor-specific offsets are supported. Table 20. Supported Power Supply Status Sensor Offsets Offset 00h Description Presence detected - Asserted if power supply module is present. Events are only logged for power supply presence upon changes in the presence state after AC power is applied (no events logged for initial state). Event Logging Assertion and Deassertion 01h Power supply failure detected - Asserted if power supply module has failed. Assertion and Deassertion The following codes for failure modes are put into the SEL Event Data 2 byte: 01h - Output voltage fault 02h - Output power fault 03h - Output over-current fault 04h - Over-temperature fault 05h - Fan fault The SEL Event Data 3 byte will have the contents of the associated PMBus* Status register to allow for showing multiple conditions for the event. For example, Data 3 will have the contents of the VOLTAGE_STATUS register at the time an Output Voltage fault was detected. Refer to the PMBus Specification for details on specific resister contents 62 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Offset 02h Platform Management Overview Description Predictive failure - Asserted if some condition, such as failing fan, has been detected that is likely to lead to a power supply module failure. Event Logging Assertion and Deassertion The following codes for warning modes are put into the SEL Event Data 2 byte: 01h - Output voltage warning 02h - Output power warning 03h - Output over-current warning 04h - Over-temperature warning 05h - Fan warning 06h - Under-voltage warning 07h - Input over-current warning 08h - Input over-power warning The SEL Event Data 3 byte will have the contents of the associated PMBus* Status register to allow for showing multiple conditions for the event. For example, Data 3 will have the contents of the VOLTAGE_STATUS register at the time an Output Voltage Warning was detected. Refer to the PMBus Specification for details on specific resister contents. 03h Power supply AC lost - Asserted if there is no AC power input to power supply module. Assertion and Deassertion 06h Configuration error - The following codes for configuration errors are put into the SEL Event Data 2 byte: 01h - The BMC cannot access the PMBus* device on the PSU but its FRU device is responding. 02h - The PMBUS_REVISION command returns a version number that is not supported (only version 1.1 and 1.2 are supported for platforms covered under this FW EAS). 03h - The PMBus* device does not successfully respond to the PMBUS_REVISION command. 04h - The PSU is incompatible with one or more PSUs that are present in the system. 05h -The PSU FW is operating in a degraded mode (likely due to a failed firmware update). Assertion and Deassertion 4.4.8 System Event Sensor The BMC supports a System Event sensor and logs SEL event for following events. Table 21. Support System Event Sensor Offsets Offset 02h Description OEM code (Undetermined system HW failure) Event Logging Assertion and Deassertion 04h PEF action Assertion only For offset 2, OEM code will be logged in event data byte 2 to indicate the type of failure. Only one value will be supported at this time, but others may be added in the future. The code for this particular fault will be 0x00 (PECI access failure) and all other values reserved. Upon detection of the CPU PECI fault condition, the offset shall assert. It shall deassert upon system power cycle or system reset. Assertion of offset 02h shall contribute a "fatal" condition to the system status as reflected in the Front Panel system status LED. Revision 1.2 Intel order number G34153-003 63 Platform Management Overview 4.4.8.1 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Update Related SEL Logging BMC FW will support a single FW Update Status sensor. This sensor is used to generate SEL events related to update of embedded firmware on the platform. This includes updates to the BMC, BIOS, and ME FW. IPMI Sensor Characteristics 1. Event reading type code: 70h (OEM defined) 2. Sensor type code: 2Bh (Version Change) 3. Rearm type: Auto This sensor is an event-only sensor that is not readable. Event generation is only enabled for assertion events. Since this is an event-only sensor it should be defined by a type-3 SDR as defined in the IPMI 2.0 Specification. Table 22. Supported Firmware Update Status Sensor Offsets Offset Description 00h 01h 02h Update started Update completed successfully Update failure Event Logging Assertion Assertion Assertion Contribution to system health OK OK OK Event Data Bytes Byte 2: [Bits 7:4] Target of update 0000b = BMC 0001b = BIOS 0010b = ME 0011b = EWS (Embedded Web server) All other values reserved [Bits 3:1] Target instance (zero-based) [Bits 0:0] Reserved Byte 3: Reserved Note: All reserved bits must be set to zero. 4.5 Platform Management Interface This chapter describes the supported BMC communication interfaces: 1. Host SMS interface by means of low pin count (LPC)/keyboard controller style (KCS) interface 2. Host SMM interface by means of low pin count (LPC)/keyboard controller style (KCS) interface 3. Intelligent Platform Management Bus (IPMB) I2C interface 4. LAN interface using the IPMI-over-LAN protocols 64 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 4.5.1 Platform Management Overview Channel Management Every messaging interface is assigned an IPMI channel ID by IPMI 2.0. Commands are provided to configure each channel for privilege levels and access modes. Table 23 shows the standard channel assignments: Table 23. Standard Channel Assignments Channel ID Interface Supports Sessions 0 Primary IPMB No 1 LAN 1 Yes 2 LAN 2 Yes 3 LAN3 1 Yes (R) (Provided by the Intel Dedicated Server Management NIC) 4 Reserved Yes 5 USB No 6 Secondary IPMB No 7 SMM No 8 - 0Dh Reserved - 2 - 0Eh Self 0Fh SMS/Receive Message Queue No Notes: 1. Optional hardware supported by the server system. 2. Refers to the actual channel used to send the request. 4.5.2 User Model The BMC supports the IPMI 2.0 user model. 15 user IDs are supported. These 15 users can be assigned to any channel. The following restrictions are placed on user-related operations: 1. User names for User IDs 1 and 2 cannot be changed. These are always "" (Null/blank) and "root" respectively. 2. User 2 ("root") always has the administrator privilege level. 3. All user passwords (including passwords for 1 and 2) may be modified. 4. User IDs 3-15 may be used freely, with the condition that user names are unique. Therefore, no other users can be named "" (Null), "root," or any other existing user name. 4.5.3 LAN Interface The BMC implements both the IPMI 1.5 and IPMI 2.0 messaging models. These provide out-of-band local area network (LAN) communication between the BMC and the network. Run-time determination of LAN channel capabilities can be determined by both standard IPMI defined mechanisms. Revision 1.2 Intel order number G34153-003 65 Platform Management Overview 4.5.3.1 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS IPMI 1.5 Messaging The communication protocol packet format consists of IPMI requests and responses encapsulated in an IPMI session wrapper for authentication, and wrapped in an RMCP packet, which is wrapped in an IP/UDP packet. Although authentication is provided, no encryption is provided, so administrating some settings, such as user passwords, through this interface is not advised. Session establishment commands are IPMI commands that do not require authentication or an associated session. The BMC supports the following authentication types over the LAN interface. 1. None (no authentication) 2. Straight password/key 3. MD5 4.5.3.2 IPMI 2.0 Messaging IPMI 2.0 messaging is built over RMCP+ and has a different session establishment protocol. The session commands are defined by RMCP+ and implemented at the RMCP+ level, not IPMI commands. Authentication is implemented at the RMCP+ level. RMCP+ provides link payload encryption, so it is possible to communicate private/sensitive data (confidentiality). The BMC supports the cipher suites identified in Table 24. Table 24. Supported RMCP+ Cipher Suites ID 01 Authentication Algorithm RAKP-none Integrity Algorithm(s) None Confidentiality Algorithm(s) None 1 RAKP-HMAC-SHA1 None None 2 RAKP-HMAC-SHA1 HMAC-SHA1-96 None 3 RAKP-HMAC-SHA1 HMAC-SHA1-96 AES-CBC-128 6 RAKP-HMAC-MD5 None None 7 RAKP-HMAC-MD5 HMAC-MD5-128 None 8 RAKP-HMAC-MD5 HMAC-MD5-128 AES-CBC-128 11 RAKP-HMAC-MD5 MD5-128 None 12 RAKP-HMAC-MD5 MD5-128 AES-CBC-128 Note: Cipher suite 0 defaults to callback privilege for security purposes. This may be changed by any administrator. For user authentication, the BMC can be configured with `null' user names, whereby password/key lookup is done based on `privilege level only', or with non-null user names, where the key lookup for the session is determined by user name. IPMI 2.0 messaging introduces payload types and payload IDs to allow data types other than IPMI commands to be transferred. IPMI 2.0 serial-over-LAN is implemented as a payload type. Table 25. Supported RMCP+ Payload Types 66 Payload Type 00h Feature IPMI message IANA N/A 01h Serial-over-LAN N/A 02h OEM explicit Intel (343) 10h - 15h Session setup N/A Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 4.5.3.3 Platform Management Overview RMCP/ASF Messaging The BMC supports RMCP ping discovery in which the BMC responds with a pong message to an RMCP/ASF ping request. This is implemented per the Intelligent Platform Management Interface Specification Second Generation v2.0. 4.5.3.4 BMC LAN Channels The BMC supports three RMII/RGMII ports that can be used for communicating with Ethernet devices. Two ports are used for communication with the on-board NICs and one is used for communication with an Ethernet PHY located on an optional add-in card (or equivalent on-board circuitry). 4.5.3.4.1 Baseboard NICs The specific Ethernet controller (NIC) used on a server is platform-specific but all baseboard device options provide support for an NC-SI manageability interface. This provides a sideband high-speed connection for manageability traffic to the BMC while still allowing for a simultaneous host access to the OS if desired. The Network Controller Sideband Interface (NC-SI) is a DMTF industry standard protocol for the side band management LAN interface. This protocol provides a fast multi-drop interface for management traffic. The baseboard NIC(s) are connected to a single BMC RMII/RGMII port that is configured for RMII operation. The NC-SI protocol is used for this connection and provides a 100 Mb/s full-duplex multi-drop interface which allows multiple NICs to be connected to the BMC. The physical layer is based upon RMII, however RMII is a point-to-point bus whereas NC-SI allows 1 master and up to 4 slaves. The logical layer (configuration commands) is incompatible with RMII. Multi-port baseboard NICs on some products will provide support for a dedicated management channel than can be configured to be hidden from the host and only used by the BMC. This mode of operation is configured by a BIOS setup option. 4.5.3.4.2 Dedicated Management Channel An additional LAN channel dedicated to BMC usage and not available to host SW is supported by an optional add-in card. There is only a PHY device present on the add-in card. The BMC has a built-in MAC module that uses the RGMII interface to link with the card's PHY. Therefore, for this dedicated management interface, the PHY and MAC are located in different devices. The PHY on the card connects to the BMC's other RMII/RGMII interface (that is, the one that is not connected to the baseboard NICs). This BMC port is configured for RGMII usage. In addition to the use of an add-in card for a dedicated management channel, on systems that support multiple Ethernet ports on the baseboard, the system BIOS provides a setup option to allow one of these baseboard ports to be dedicated to the BMC for manageability purposes. When this is enabled, that port is hidden from the OS. 4.5.3.4.3 Concurrent Server Management Use of Multiple Ethernet Controllers Provided the HW supports a management link between the BMC and a NIC port, the BMC FW supports concurrent OOB LAN management sessions for the following combination: Two on-board NIC ports One on-board NIC and the optional dedicated add-in management NIC. Two on-board NICs and optional dedicated add-in management NIC. Revision 1.2 Intel order number G34153-003 67 Platform Management Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS All NIC ports must be on different subnets for the above concurrent usage models. MAC addresses are assigned for management NICs from a pool of up to 3 MAC addresses allocated specifically for manageability. The total number of MAC addresses in the pool is dependent on the product HW constraints (for example,a board with 2 NIC ports available for manageability would have a MAC allocation pool of 2 addresses).For these channels, support can be enabled for IPMI-over-LAN and DHCP. For security reasons, embedded LAN channels have the following default settings: IP Address: Static All users disabled IPMI-enabled network interfaces may not be placed on the same subnet. This includes the Intel(R) Dedicated Server Management NIC and either of the BMC's embedded network interfaces. Host-BMC communication over the same physical LAN connection - also known as "loopback" - is not supported. This includes "ping" operations. On baseboards with more than two onboard NIC ports, only the first two ports can be used as BMC LAN channels. The remaining ports have no BMC connectivity. Maximum bandwidth supported by BMC LAN channels are as follows: BMC LAN1 (Baseboard NIC port) ----- 100M (10M in DC off state) BMC LAN 2 (Baseboard NIC port) ----- 100M (10M in DC off state) BMC LAN 3 (Dedicated NIC) ----- 1000M 4.5.3.5 Dedicated Management NIC MAC Address For EPSD Platforms Based on Intel(R) Xeon(R) Processor E5 4600/2600/2400/1600/1400 Product Families each server board has either five or seven MAC addresses assigned to it at the Intel factory. The printed MAC address is assigned to NIC1 on the server board. If the platform has two NIC built into the main board then there will be five MAC addresses assigned as follows: NIC 1 MAC address (for OS usage) NIC 2 MAC address = NIC 1 MAC address + 1 (for OS usage) BMC LAN channel 1 MAC address = NIC1 MAC address + 2 BMC LAN channel 2 MAC address = NIC1 MAC address + 3 BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 4 If the platform has four NIC built into the main board then there will be seven MAC addresses assigned as follows: 68 NIC 1 MAC address (for OS usage) NIC 2 MAC address = NIC 1 MAC address + 1 (for OS usage) NIC 3 MAC address = NIC 1 MAC address + 2 (for OS usage) NIC 4 MAC address = NIC 1 MAC address + 3 (for OS usage) BMC LAN channel 1 MAC address = NIC1 MAC address + 4 BMC LAN channel 2 MAC address = NIC1 MAC address + 5 BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 6. Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 4.5.3.6 Platform Management Overview IPV6 Support In addition to IPv4, Intel(R) S1400/S1600/S2400/S2600 Server Platforms support IPv6 for manageability channels. Configuration of IPv6 is provided by extensions to the IPMI Set and Get LAN Configuration Parameters commands as well as through a Web Console IPv6 configuration web page. The BMC supports IPv4 and IPv6 simultaneously so they are both configured separately and completely independently. For example, IPv4 can be DHCP configured while IPv6 is statically configured or vice versa. 4.5.3.6.1 LAN Failover The BMC FW provides a LAN failover capability such that the failure of the system HW associated with one LAN link will result in traffic being rerouted to an alternate link. This functionality is configurable by IPMI methods as well as by the BMC's Embedded UI, allowing for user to specify the physical LAN links constitute the redundant network paths or physical LAN links constitute different network paths. BMC will support only a all or nothing" approach - that is, all interfaces bonded together, or none are bonded together. The LAN Failover feature applies only to BMC LAN traffic. It bonds all available Ethernet devices but only one is active at a time. When enabled, If the active connection's leash is lost, one of the secondary connections is automatically configured so that it has the same IP address (the next active LAN link will be chosen randomly from the pool of backup LAN links with link status as "UP"). Traffic immediately resumes on the new active connection. The LAN Failover enable/disable command may be sent at any time. After it has been enabled, standard IPMI commands for setting channel configuration that specify a LAN channel other than the first will return an error code. Standard IPMI commands for getting channel configuration will return the cached settings for the inactive channels. 4.5.3.7 BMC IP Address Configuration Enabling the BMC's network interfaces requires using the Set LAN Configuration Parameter command to configure LAN configuration parameter 4, IP Address Source. 4.5.3.8 DHCP BMC Hostname The BMC allows setting a DHCP Hostname. DHCP Hostname can be set regardless of the IP Address source configured on the BMC. But this parameter is only used if the IP Address source is set to DHCP. 4.5.3.9 Address Resolution Protocol (ARP) The BMC can receive and respond to ARP requests on BMC NICs. Gratuitous ARPs are supported, and disabled by default. 4.5.3.10 Virtual Local Area Network (VLAN) The BMC supports VLAN as defined by IPMI 2.0 specifications. VLAN is supported internally by the BMC, not through switches. VLAN provides a way of grouping a set of systems together so that they form a logical network. This feature can be used to set up a management VLAN where only devices which are members of the VLAN will receive packets related to management and members of the VLAN will be isolated from any other network traffic. Please note that VLAN does not change the behavior of the host network setting, it only affects the BMC LAN communication. Revision 1.2 Intel order number G34153-003 69 Platform Management Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS LAN configuration options are now supported (by means of the Set LAN Config Parameters command, parameters 20 and 21) that allow support for 802.1Q VLAN (Layer 2). This allows VLAN headers/packets to be used for IPMI LAN sessions. VLAN ID's are entered and enabled by means of parameter 20 of the Set LAN Config Parameters IPMI command. When a VLAN ID is configured and enabled, the BMC only accepts packets with that VLAN tag/ID. Conversely, all BMC generated LAN packets on the channel include the given VLAN tag/ID. Valid VLAN ID's are 1 through 4094, VLAN ID's of 0 and 4095 are reserved, per the 802.1Q VLAN specification. Only one VLAN can be enabled at any point in time on a LAN channel. If an existing VLAN is enabled, it must first be disabled prior to configuring a new VLAN on the same LAN channel. Parameter 21 (VLAN Priority) of the Set LAN Config Parameters IPMI command is now implemented and a range from 0-7 will be allowed for VLAN Priorities. Please note that bits 3 and 4 of Parameter 21 are considered Reserved bits. Parameter 25 (VLAN Destination Address) of the Set LAN Config Parameters IPMI command is not supported and returns a completion code of 0x80 (parameter not supported) for any read/write of parameter 25. If the BMC IP address source is DHCP, then the following behavior is seen: If the BMC is first configured for DHCP (prior to enabling VLAN), when VLAN is enabled, the BMC performs a discovery on the new VLAN in order to obtain a new BMC IP address. If the BMC is configured for DHCP (before disabling VLAN), when VLAN is disabled, the BMC performs a discovery on the LAN in order to obtain a new BMC IP address. If the BMC IP address source is Static, then the following behavior is seen: If the BMC is first configured for static (prior to enabling VLAN), when VLAN is enabled, the BMC has the same IP address that was configured before. It is left to the management application to configure a different IP address if that is not suitable for VLAN. If the BMC is configure for static (prior to disabling VLAN), when VLAN is disabled, the BMC has the same IP address that was configured before. It is left to the management application to configure a different IP address if that is not suitable for LAN. 4.5.3.11 Secure Shell (SSH) Secure Shell (SSH) connections are supported for one SMASH-CLP session to the BMC. 4.5.3.12 Serial-over-LAN (SOL 2.0) The BMC supports IPMI 2.0 SOL. IPMI 2.0 introduced a standard serial-over-LAN feature. This is implemented as a standard payload type (01h) over RMCP+. Three commands are implemented for SOL 2.0 configuration. 1. "Get SOL 2.0 Configuration Parameters" and "Set SOL 2.0 Configuration Parameters": These commands are used to get and set the values of the SOL configuration parameters. The parameters are implemented on a per-channel basis. 2. "Activating SOL": This command is not accepted by the BMC. It is sent by the BMC when SOL is activated to notify a remote client of the switch to SOL. 3. Activating a SOL session requires an existing IPMI-over-LAN session. If encryption is used, it should be negotiated when the IPMI-over LAN session is established. Intel(R) Server Board S2600IP SOL 70 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Platform Management Overview sessions are supported on serial port A (COM1). Intel(R) Workstation Board S2600IP SOL sessions are supported on serial port B (COM2). 4.5.3.13 Platform Event Filter (PEF) The BMC includes the ability to generate a selectable action, such as a system power-off or reset, when a match occurs to one of a configurable set of events. This capability is called Platform Event Filtering, or PEF. One of the available PEF actions is to trigger the BMC to send a LAN alert to one or more destinations. The BMC supports 20 PEF filters. The first twelve entries in the PEF filter table are pre-configured (but may be changed by the user). The remaining entries are left blank, and may be configured by the user. Table 26. Factory Configured PEF Table Entries Event Filter Number Offset Mask Events 1 Non-critical, critical and nonrecoverable Temperature sensor out of range 2 Non-critical, critical and nonrecoverable Voltage sensor out of range 3 Non-critical, critical and nonrecoverable Fan failure 4 General chassis intrusion Chassis intrusion (security violation) 5 Failure and predictive failure Power supply failure 6 Uncorrectable ECC BIOS 7 POST error BIOS: POST code error 8 FRB2 Watchdog Timer expiration for FRB2 9 Policy Correction Time Node Manager 10 Power down, power cycle, and reset Watchdog timer 11 OEM system boot event System restart (reboot) 12 Drive Failure, Predicted Failure Hot Swap Controller Additionally, the BMC supports the following PEF actions: Power off Power cycle Reset OEM action Alerts The "Diagnostic interrupt" action is not supported. 4.5.3.14 LAN Alerting The BMC supports sending embedded LAN alerts, called SNMP PET (Platform Event traps), and SMTP email alerts. The BMC supports a minimum of four LAN alert destinations. Revision 1.2 Intel order number G34153-003 71 Platform Management Overview 4.5.3.14.1 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS SNMP Platform Event Traps (PETs) This feature enables a target system to send SNMP traps to a designated IP address by means of LAN. These alerts are formatted per the Intelligent Platform Management Interface Specification Second Generation v2.0. A MIB file associated with the traps is provided with the BMC firmware to facilitate interpretation of the traps by external software. The format of the MIB file is covered under RFC 2578. 4.5.3.15 Alert Policy Table Associated with each PEF entry is an alert policy that determines which IPMI channel the alert is to be sent. There is a maximum of 20 alert policy entries. There are no pre-configured entries in the alert policy table because the destination types and alerts may vary by user. Each entry in the alert policy table contains four bytes for a maximum table size of 80 bytes. 4.5.3.15.1 E-mail Alerting The Embedded Email Alerting feature allows the user to receive e-mails alerts indicating issues with the server. This allows e-mail alerting in an OS-absent (for example, Pre-OS and OS-Hung) situation. This feature provides support for sending e-mail by means of SMTP, the Simple Mail Transport Protocol as defined in Internet RC 821. The e-mail alert provides a text string that describes a simple description of the event. SMTP alerting is configured using the embedded web server. 4.5.3.16 SM-CLP (SM-CLP Lite) SMASH refers to Systems Management Architecture for Server Hardware. SMASH is defined by a suite of specifications, managed by the DMTF, that standardize the manageability interfaces for server hardware. CLP refers to Command Line Protocol. SM-CLP is defined by the Server Management Command Line Protocol Specification (SM-CLP) ver1.0, which is part of the SMASH suite of specifications. The specifications and further information on SMASH can be found at the DMTF website (http://www.dmtf.org/). The BMC provides an embedded "lite" version of SM-CLP that is syntax-compatible but not considered fully compliant with the DMTF standards. 4.5.3.17 Embedded Web Server BMC Base manageability provides an embedded web server and an OEM-customizable web GUI which exposes the manageability features of the BMC base feature set. It is supported over all on-board NICs that have management connectivity to the BMC as well as an optional dedicated add-in management NIC. At least two concurrent web sessions from up to two different users is supported. The embedded web user interface shall support the following client web browsers: Microsoft Internet Explorer 7.0* Microsoft Internet Explorer 8.0* Microsoft Internet Explorer 9.0* Mozilla Firefox 3.0* Mozilla Firefox 3.5* Mozilla Firefox 3.6* The embedded web user interface supports strong security (authentication, encryption, and firewall support) since it enables remote server configuration and control. Embedded web server uses ports #80 and #443. The user interface presented by the embedded web user interface 72 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Platform Management Overview shall authenticate the user before allowing a web session to be initiated. Encryption using 128bit SSL is supported. User authentication is based on user id and password. The GUI presented by the embedded web server authenticates the user before allowing a web session to be initiated. It presents all functions to all users but grays-out those functions that the user does not have privilege to execute. (For example, if a user does not have privilege to power control, then the item shall be displayed in grey-out font in that user's UI display). The web GUI also provides a launch point for some of the advanced features, such as KVM and media redirection. These features are grayed out in the GUI unless the system has been updated to support these advanced features. Additional features supported by the web GUI includes: Presents all the Basic features to the users. Power on/off/reset the server and view current power state. Displays BIOS, BMC, ME and SDR version information. Display overall system health. Configuration of various IPMI over LAN parameters for both IPV4 and IPV6 Configuration of alerting (SNMP and SMTP). Display system asset information for the product, board, and chassis. Display of BMC-owned sensors (name, status, current reading, enabled thresholds), including color-code status of sensors. Provides ability to filter sensors based on sensor type (Voltage, Temperature, Fan and Power supply related) Automatic refresh of sensor data with a configurable refresh rate. On-line help. Display/clear SEL (display is in easily understandable human readable format). Supports major industry-standard browsers (Microsoft Internet Explorer* and Mozilla Firefox*). The GUI session automatically times-out after a user-configurable inactivity period. By default, this inactivity period is 30 minutes. Embedded Platform Debug feature - Allow the user to initiate a "diagnostic dump" to a file that can be sent to Intel for debug purposes. Virtual Front Panel. The Virtual Front Panel provides the same functionality as the local front panel. The displayed LEDs match the current state of the local panel LEDs. The displayed buttons (for example,power button) can be used in the same manner as the local buttons. Display of ME sensor data. Only sensors that have associated SDRs loaded will be displayed. Ability to save the SEL to a file. Ability to force HTTPS connectivity for greater security. This is provided through a configuration option in the UI. Display of processor and memory information as is available over IPMI over LAN. Ability to get and set Node Manager (NM) power policies. Display of power consumed by the server. Ability to view and configure VLAN settings. Warn user the reconfiguration of IP address will cause disconnect. Capability to block logins for a period of time after several consecutive failed login attempts. The lock-out period and the number of failed logins that initiates the lock-out period are configurable by the user. Server Power Control - Ability to force into Setup on a reset. Revision 1.2 Intel order number G34153-003 73 Platform Management Overview 4.5.3.18 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Virtual Front Panel Virtual Front Panel is the module present as "Virtual Front Panel" on the left side in the embedded web server when "remote Control" tab is clicked. Main Purpose of the Virtual Front Panel is to provide the front panel functionality virtually. Virutal Front Panel (VFP) will mimic the status LED and Power LED status and Chassis ID alone. It is automatically in sync with BMC every 40 seconds. For any abnormal status LED state, Virtual Front Panel will get the reason behind the abnormal or status LED changes and displayed in VFP side. As Virtual Front Panel uses the chassis control command for power actions. It won't log the Front button press event since Logging the front panel press event for Virtual Front Panel press will mislead the administrator. For Reset from Virtual Front Panel, the reset will be done by a "Chassis control" command. For Reset from Virtual Front Panel, the restart cause will be because of "Chassis control" command. During Power action, Power button/Reset button should not accept the next action until current Power action is complete and the acknowledgment from BMC is received. EWS will provide a valid message during Power action until it completes the current Power action. The VFP does not have any effect on whether the front panel is locked by "Set Front Panel Enables" command. The chassis ID LED provides a visual indication of a system being serviced. The state of the chassis ID LED is affected by the following actions: Toggled by turning the chassis ID button on or off. There is no precedence or lock-out mechanism for the control sources. When a new request arrives, previous requests are terminated. For example, if the chassis ID button is pressed, then the chassis ID LED changes to solid on. If the button is pressed again, then the chassis ID LED turns off. Note that the chassis ID will turn on because of the original chassis ID button press and will reflect in the Virtual Front Panel after VFP sync with BMC. Virtual Front Panel won't reflect the chassis LED software blinking by the software command as there is no mechanism to get the chassis ID Led status. Only Infinite chassis ID ON/OFF by the software command will reflect in EWS during automatic /manual EWS sync up with BMC. Virtual Front Panel help should available for virtual panel module. At present, NMI button in VFP is disabled in Intel(R) S1400/S1600/S2400/S2600 Server Platforms. It can be used in future. 4.5.3.19 Embedded Platform Debug The Embedded Platform Debug feature supports capturing low-level diagnostic data (applicable MSRs, PCI config-space registers, and so on). This feature allows a user to export this data into a file that is retrievable from the embedded web GUI, as well as through host and remote IPMI methods, for the purpose of sending to an Intel engineer for an enhanced debugging capability. The files are compressed, encrypted, and password protected. The file is not meant to be viewable by the end user but rather to provide additional debugging capability to an Intel support engineer. 4.5.3.20 Data Center Management Interface (DCMI) The DCMI Specification is an emerging standard that is targeted to provide a simplified management interface for Internet Portal Data Center (IPDC) customers. It is expected to become a requirement for 74 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Platform Management Overview server platforms which are targeted for IPDCs. DCMI is an IPMI-based standard that builds upon a set of required IPMI standard commands by adding a set of DCMI-specific IPMI OEM commands. Intel(R) S1400/S1600/S2400/S2600 Server Platforms will be implementing the mandatory DCMI features in the BMC firmware (DCMI 1.1 Errata 1 compliance). Please refer to DCMI 1.1 errata 1 spec for details. Only mandatory commands will be supported. No support for optional DCMI commands. Optional power management and SEL roll over feature is not supported. DCMI Asset tag will be independent of baseboard FRU asset Tag. Please refer table DCMI Group Extension Commands for more details on DCMI commands. 4.5.3.21 Lightweight Directory Authentication Protocol (LDAP) The Lightweight Directory Access Protocol (LDAP) is an application protocol supported by the BMC for the purpose of authentication and authorization. The BMC user connects with an LDAP server for login authentication. This is only supported for non-IPMI logins including the embedded web UI and SM-CLP. IPMI users/passwords and sessions are not supported over LDAP. LDAP can be configured (IP address of LDAP server, port, and so on) from the BMC's Embedded Web UI. LDAP authentication and authorization is supported over the any NIC configured for system management. The BMC uses a standard Open LDAP implementation for Linux. Only open LDAP is supported by BMC. Windows and Novel LDAP are not supported. 4.6 BMC Firmware Update 4.6.1 The BMC firmware release Number The BMC firmware releases are numbered as follows: AB.CD.XXX Where: CD is a two digit number starting with 00 for the first release. This is the number returned in minor ID in Get Device ID response. B is major release number (1 for the first major release typically at first production shipment). A is point release indicator (A=0 means this is a regular official release, A=1 means this is a point release for limited distribution). A hex representation of "AB" is returned in major ID in Get Device ID response. XXX is the build number for internal tracking. This number is returned in OEM bytes of Get Device ID response. 4.6.2 Boot Recovery Mode The BMC's boot block supports firmware transfer updates. The Operational Firmware Transfer mode preserves several files in the PIA Linux file system. Boot Recovery mode cannot preserve the files because it does not understand Linux file systems, and treats it as a large binary data section. This means a Boot Recovery update completely replaces the PIA with the factory default version: an empty SEL, a default SDR, and default IPMI configuration and user settings. Boot Recovery mode can successfully complete an update in some situations where the Operational Firmware Transfer mode will fail. If there is an incompatibility or bug in the operational code causing it to crash or hang, only a Boot Recovery Mode Update works. Another example is if the flash layout of the sections changes across an update. Because the operational Firmware Transfer mode tries to preserve Revision 1.2 Intel order number G34153-003 75 Platform Management Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS the contents of the PIA section, in this case, it will corrupt the flash where the old PIA section was. Because the Boot Recovery mode is blindly writing binary data to flash, in this case, it will succeed. There are two ways to enter Boot Recovery mode: The Force Firmware Update jumper is asserted when A/C power is applied. The operational code is corrupt and the boot loader cannot boot. In the Boot Recovery mode, the BMC only responds to the small set of commands listed above. Only the KCS SMS interface is supported; USB-based Fast Firmware Update is not supported. 4.6.3 Force Firmware Update Jumper The Force Firmware Update jumper can be used to put the BMC in Boot Recovery mode for a low-level update. It causes the BMC to abort its normal boot process and stay in the boot loader without executing any Linux code. The jumper is normally in the de-asserted position. The system must be completely powered off (A/C power removed) before the jumper is moved. After power is re-applied and the firmware update is complete, the system must be powered off again and the jumper must be returned to the de-asserted position before normal operation can begin. There is no boot-block-write protection jumper. 4.6.4 Fast Firmware Update over USB The BMC supports a Fast Firmware Update mode in addition to the standard KCS SMS interface. This is a special protocol that goes over the USB connection between the host and the BMC. 76 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 4.7 Platform Management Overview Advanced Management Feature Support This section explains the advanced management features supported by the BMC firmware. 4.7.1 Enabling Advanced Management Features The Advanced management features are to be delivered as part of the BMC FW image. The BMC's baseboard SPI flash contains code/data for both the Basic and Advanced features. An optional add-in card Intel(R) RMM4 lite is used as the activation mechanism. When the BMC FW initializes, it attempts to access the Intel(R) RMM4 lite. If the attempt to access Intel(R) RMM4 lite is successful, then the BMC activates the Advanced features. Advanced manageability features are supported over all NIC ports enabled for server manageability. This includes baseboard NICs as well as the LAN channel provided by the optional Dedicated NIC add-in card. RMM4 is comprised of two boards - RMM4 lite and the optional Dedicated Server Management NIC (DMN). If the optional Dedicated Server Management NIC is not used then the traffic can only go through the onboard Integrated BMC-shared NIC and share network bandwidth with the host system. Table 27. Enabling Advanced Management Features Manageability Hardware Benefits Intel(R) Integrated BMC Comprehensive IPMI based base manageability features Intel(R) Remote Management Module 4 - Lite Package contains one module - 1- Key for advance Manageability features. No dedicated NIC for management Enables KVM and media redirection from the onboard NIC Intel(R) Remote Management Module 4 Package includes 2 modules - 1 - key for advance features 2 - Dedicated NIC (1Gbe) for management Dedicated NIC for management traffic. Higher bandwidth connectivity for KVM and media Redirection with 1Gbe NIC. 4.7.2 Keyboard, Video, Mouse (KVM) Redirection The BMC firmware supports keyboard, video, and mouse redirection (KVM) over LAN. This feature is available remotely from the embedded web server as a Java applet. This feature is only enabled when the Intel(R) RMM4 lite is present. The client system must have a Java Runtime Environment (JRE) version 6.0 or later to run the KVM or media redirection applets. The BMC supports an embedded KVM application (Remote Console) that can be launched from the embedded web server from a remote console. USB1.1 or USB 2.0 based mouse and keyboard redirection are supported. It is also possible to use the KVM-redirection (KVM-r) session concurrently with media-redirection (media-r). This feature allows a user to interactively use the keyboard, video, and mouse (KVM) functions of the remote server as if the user were physically at the managed server. KVM redirection console support the following keyboard layouts: English, Dutch, French, German, Italian, Russian, and Spanish. Revision 1.2 Intel order number G34153-003 77 Platform Management Overview Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS KVM redirection includes a "soft keyboard" function. The "soft keyboard" is used to simulate an entire keyboard that is connected to the remote system. The "soft keyboard" functionality supports the following layouts: English, Dutch, French, German, Italian, Russian, and Spanish. The KVM-redirection feature automatically senses video resolution for best possible screen capture and provides high-performance mouse tracking and synchronization. It allows remote viewing and configuration in pre-boot POST and BIOS setup, once BIOS has initialized video. Other attributes of this feature include: Encryption of the redirected screen, keyboard, and mouse Compression of the redirected screen. Ability to select a mouse configuration based on the OS type. supports user definable keyboard macros. KVM redirection feature supports the following resolutions and refresh rates: 640x480 at 60Hz, 72Hz, 75Hz, 85Hz, 100Hz 800x600 at 60Hz, 72Hz, 75Hz, 85Hz 1024x768 at 60Hx, 72Hz, 75Hz, 85Hz 1280x960 at 60Hz 1280x1024 at 60Hz 1600x1200 at 60Hz 1920x1080 (1080p), 1920x1200 (WUXGA) 1650x1080 (WSXGA+) 4.7.2.1 Force-enter BIOS Setup KVM redirection can present an option to force-enter BIOS Setup. This enables the system to enter F2 setup while booting which is often missed by the time the remote console redirects the video. 4.7.3 Media Redirection The embedded web server provides a Java applet to enable remote media redirection. This may be used in conjunction with the remote KVM feature, or as a standalone applet. The media redirection feature is intended to allow system administrators or users to mount a remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from this device. The following capabilities are supported: The operation of remotely mounted devices is independent of the local devices on the server. Both remote and local devices are useable in parallel. Either IDE (CD-ROM, floppy) or USB devices can be mounted as a remote device to the server. It is possible to boot all supported operating systems from the remotely mounted device and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. See the Tested/supported Operating System List for more information. Media redirection supports redirection for both a virtual CD device and a virtual Floppy/USB device concurrently. The CD device may be either a local CD drive or else an ISO image file; the Floppy/USB device may be either a local Floppy drive, a local USB device, or else a disk image file. 78 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Platform Management Overview The media redirection feature supports multiple encryption algorithms, including RC4 and AES. The actual algorithm that is used is negotiated with the client based on the client's capabilities. A remote media session is maintained even when the server is powered-off (in standby mode). No restart of the remote media session is required during a server reset or power on/off. An BMC reset (for example,due to an BMC reset after BMC FW update) will require the session to be re-established The mounted device is visible to (and useable by) managed system's OS and BIOS in both pre-boot and post-boot states. The mounted device shows up in the BIOS boot order and it is possible to change the BIOS boot order to boot from this remote device. It is possible to install an operating system on a bare metal server (no OS present) using the remotely mounted device. This may also require the use of KVM-r to configure the OS during install. USB storage devices will appear as floppy disks over media redirection. This allows for the installation of device drivers during OS installation. If either a virtual IDE or virtual floppy device is remotely attached during system boot, both the virtual IDE and virtual floppy are presented as bootable devices. It is not possible to present only a single-mounted device type to the system BIOS. Revision 1.2 Intel order number G34153-003 79 Platform Management Overview 4.8 4.8.1 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Intel(R)Intelligent Power Node Manager (NM) Overview Power management deals with requirements to manage processor power consumption and manage power at the platform level to meet critical business needs. Node Manager (NM) is a platform resident technology that enforces power capping and thermal-triggered power capping policies for the platform. These policies are applied by exploiting subsystem knobs (such as processor P and T states) that can be used to control power consumption. NM enables data center power management by exposing an external interface to management software through which platform policies can be specified. It also implements specific data center power management usage models such as power limiting, and thermal monitoring. The NM feature is implemented by a complementary architecture utilizing the ME, BMC, BIOS, and an ACPI-compliant OS. The ME provides the NM policy engine and power control/limiting functions (referred to as Node Manager or NM) while the BMC provides the external LAN link by which external management software can interact with the feature. The BIOS provides system power information utilized by the NM algorithms and also exports ACPI Source Language (ASL) code used by OS-Directed Power Management (OSPM) for negotiating processor P and T state changes for power limiting. PMBus*compliant power supplies provide the capability to monitoring input power consumption, which is necessary to support NM. 4.8.1.1 Hardware Requirements NM is supported only on platforms that have the NM FW functionality loaded and enabled on the Management Engine (ME) in the SSB and that have a BMC present to support the external LAN interface to the ME. NM power limiting features requires a means for the ME to monitor input power consumption for the platform. This capability is generally provided by means of PMBus*-compliant power supplies although an alternative model using a simpler SMBus* power monitoring device is possible (there is potential loss in accuracy and responsiveness using non-PMBus* devices). The NM SmaRT/CLST feature does specifically require PMBus*-compliant power supplies as well as additional hardware on the baseboard. 4.8.1.2 Features NM provides feature support for policy management, monitoring and querying, alerts and notifications, and an external interface protocol. The policy management features implement specific IT goals that can be specified as policy directives for NM. Monitoring and querying features enable tracking of power consumption. Alerts and notifications provide the foundation for automation of power management in the data center management stack. The external interface specifies the protocols that must be supported in this version of NM. 4.8.1.3 ME Firmware Update On server platforms, the ME FW uses a single operational image with a limited-functionality recovery image. In order to upgrade an operational image, a boot to recovery image must be performed. Unlike last generation platforms, the ME FW does not support an IPMI update mechanism except for the case that the system is configured with a dual-ME (redundant) image. In order to conserve flash space, which the ME FW shares with BIOS, EPSD systems only support a single ME image. For this case, ME update is only supported by means of BIOS performing a direct update of the flash component. The recovery image only provides the basic functionality that is required to perform the update; therefore other ME FW features are not functional therefore when the update is in progress. 80 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 4.8.1.4 Platform Management Overview SmaRT/CLST The power supply optimization provided by SmaRT/CLST relies on a platform HW capability as well as ME FW support. When a PMBus*-compliant power supply detects insufficient input voltage, an overcurrent condition, or an over-temperature condition, it will assert the SMBAlert# signal on the power supply SMBus* (that is, the PMBus*). Through the use of external gates, this results in a momentary assertion of the PROCHOT# and MEMHOT# signals to the processors, thereby throttling the processors and memory. The ME FW also sees the SMBAlert# assertion, queries the power supplies to determine the condition causing the assertion, and applies an algorithm to either release or prolong the throttling, based on the situation. System power control modes include: 1. SmaRT: Low AC input voltage event; results in a onetime momentary throttle for each event to the maximum throttle state 2. Electrical Protection CLST: High output energy event; results in a throttling hiccup mode with fixed maximum throttle time and a fix throttle release ramp time. 3. Thermal Protection CLST: High power supply thermal event; results in a throttling hiccup mode with fixed maximum throttle time and a fix throttle release ramp time. When the SMBAlert# signal is asserted, the fans will be gated by HW for a short period (~100ms) to reduce overall power consumption. It is expected that the interruption to the fans will be of short enough duration to avoid false lower threshold crossings for the fan tach sensors; however, this may need to be comprehended by the fan monitoring FW if it does have this side-effect. ME FW will log an event into the SEL to indicate when the system has been throttled by the SmaRT/CLST power management feature. This is dependent on ME FW support for this sensor. Please refer ME FW EPS for SEL log details. 4.8.1.4.1 Dependencies on PMBus*-compliant Power Supply Support The SmaRT/CLST system feature depends on functionality present in the ME NM SKU. This feature requires power supplies that are compliant with the PMBus Specification, Revision 1.2. 4.9 EU Lot 6 Mode The European Union has set forth a stringent standby power consumption target for systems that are used as primary computing devices in office environments. Owing to the fact in office environments, pedestal servers are being used more and more as workstations and that Value servers could make their way into Home servers, this solution is being requested for some pedestal servers. HW support for EU Lot6 will only be available for specific EPSD pedestal products. In order to meet the standby power requirements for EU Lot6 it is necessary to remove power to the BMC, along with other components, when in the S5 state. As this operational mode impacts system feature support, the user has the option of enabling and disabling this mode from the BIOS setup screen utility. BIOS is responsible for enabling/disabling the system hardware for EU Lot6 operation. It notifies the BMC of the current state with the OEM command Set EULot6 Mode. The BMC saves the state in persistent store and uses it to control special EU Lot6 internal processing during boot, sensor monitoring, and so on as needed. Wake-on-LAN (WOL) is not supported in EU Lot6 mode. 4.9.1.1 Impact to System Features The following system features are lost or impacted when EU Lot6 mode is enabled: Increased boot time (~15-20s) when system is DC power cycled. Revision 1.2 Intel order number G34153-003 81 System Security o Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS This is due to the fact that both the BMC and BIOS are booting at the same time when the system is powered on (to S0 state). BIOS will need to allow extra time for the BMC to initialize to the point where it can communicate with BIOS. Note: Even when EU Lot6 is not enabled and the system is AC cycled, this increased boot time is applicable if a user immediately attempts to power the system up (for example, pressing the power button), as in this case both the BMC and BIOS are booting at the same time. No LAN manageability when on standby, and therefore no remote OOB power on by BMC. No support for SOL or KVM for monitoring the entire boot process. o Since BMC is initializing at the same time as BIOS, it will not be possible to have an SOL or KVM session established from the beginning of the system boot. FP status LED will behave differently (it will be off when on standby) rather than showing fault conditions present at the time the system was powered down. No beep code due to uninstalled CPU. No monitoring of any sensors when on standby. No detection/logging of any ThermTrip faults. o These result as the system is shut down by HW so BMC will not be available to detect that they occurred. Sensor monitoring after DC power-on will be delayed by the time it takes BMC to initialize its sensor subsystem (~15 to 20s), possibly losing SEL events or failing to provide correct FP LED status LED indication. Note: This delay occurs on each AC cycle even when EU Lot6 mode is disabled. Chassis intrusion not detected when in standby 5. System Security 5.1 BIOS Password Protection The BIOS uses passwords to prevent unauthorized tampering with the server setup. Passwords can restrict entry to the BIOS Setup, restrict use of the Boot Popup menu, and suppress automatic USB device reordering. 82 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS System Security There is also an option to require a Power On password entry in order to boot the system. If the Power On Password function is enabled in Setup, the BIOS will halt early in POST to request a password before continuing POST. Both Administrator and User passwords are supported by the BIOS. An Administrator password must be installed in order to set the User password. The maximum length of a password is 14 characters. A password can have alphanumeric (a-z, A-Z, 0-9) characters and it is case sensitive. Certain special characters are also allowed, from the following set: !@#$%^&*()-_+=? The Administrator and User passwords must be different from each other. An error message will be displayed if there is an attempt to enter the same password for one as for the other. The use of "Strong Passwords" is encouraged, but not required. In order to meet the criteria for a "Strong Password", the password entered must be at least 8 characters in length, and must include at least one each of alphabetic, numeric, and special characters. If a "weak" password is entered, a popup warning message will be displayed, although the weak password will be accepted. Once set, a password can be cleared by changing it to a null string. This requires the Administrator password, and must be done through BIOS Setup or other explicit means of changing the passwords. Clearing the Administrator password will also clear the User password. Alternatively, the passwords can be cleared by using the Password Clear jumper if necessary. Resetting the BIOS configuration settings to default values (by any method) has no effect on the Administrator and User passwords. Entering the User password allows the user to modify only the System Time and System Date in the Setup Main screen. Other setup fields can be modified only if the Administrator password has been entered. If any password is set, a password is required to enter the BIOS setup. The Administrator has control over all fields in the BIOS setup, including the ability to clear the User password and the Administrator password. It is strongly recommended that at least an Administrator Password be set, since not having set a password gives everyone who boots the system the equivalent of Administrative access. Unless an Administrator password is installed, any User can go into Setup and change BIOS settings at will. In addition to restricting access to most Setup fields to viewing only when a User password is entered, defining a User password imposes restrictions on booting the system. In order to simply boot in the defined boot order, no password is required. However, the F6 Boot popup prompts for a password, and can only be used with the Administrator password. Also, when a User password is defined, it suppresses the USB Reordering that occurs, if enabled, when a new USB boot device is attached to the system. A User is restricted from booting in anything other than the Boot Order defined in the Setup by an Administrator. As a security measure, if a User or Administrator enters an incorrect password three times in a row during the boot sequence, the system is placed into a halt state. A system reset is required to exit out of the halt state. This feature makes it more difficult to guess or break a password. In addition, on the next successful reboot, the Error Manager displays a Major Error code 0048, which also logs a SEL event to alert the authorized user or administrator that a password Revision 1.2 Intel order number G34153-003 83 System Security Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS access failure has occurred. 5.2 Trusted Platform Module (TPM) Support The Trusted Platform Module (TPM) option is a hardware-based security device that addresses the growing concern on boot process integrity and offers better data protection. TPM protects the system start-up process by ensuring it is tamper-free before releasing system control to the operating system. A TPM device provides secured storage to store data, such as security keys and passwords. In addition, a TPM device has encryption and hash functions. The server board implements TPM as per TPM PC Client Specifications revision 1.2 by the Trusted Computing Group (TCG). A TPM device is optionally installed onto a high density 14-pin connector labeled "TPM" on the server board, and is secured from external software attacks and physical theft. A pre-boot environment, such as the BIOS and operating system loader, uses the TPM to collect and store unique measurements from multiple factors within the boot process to create a system fingerprint. This unique fingerprint remains the same unless the pre-boot environment is tampered with. Therefore, it is used to compare to future measurements to verify the integrity of the boot process. After the system BIOS completes the measurement of its boot process, it hands off control to the operating system loader and in turn to the operating system. If the operating system is TPMenabled, it compares the BIOS TPM measurements to those of previous boots to make sure the system was not tampered with before continuing the operating system boot process. Once the operating system is in operation, it optionally uses TPM to provide additional system and data security (for example, Microsoft Vista* supports Bitlocker drive encryption). 5.2.1 TPM security BIOS The BIOS TPM support conforms to the TPM PC Client Implementation Specification for Conventional BIOS and to the TPM Interface Specification, and the Microsoft Windows BitLocker* Requirements. The role of the BIOS for TPM security includes the following: Measures and stores the boot process in the TPM microcontroller to allow a TPM enabled operating system to verify system boot integrity. Produces EFI and legacy interfaces to a TPM-enabled operating system for using TPM. Produces ACPI TPM device and methods to allow a TPM-enabled operating system to send TPM administrative command requests to the BIOS. Verifies operator physical presence. Confirms and executes operating system TPM administrative command requests. Provides BIOS Setup options to change TPM security states and to clear TPM ownership. For additional details, refer to the TCG PC Client Specific Implementation Specification, the TCG PC Client Specific Physical Presence Interface Specification, and the Microsoft BitLocker* 84 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS System Security Requirement documents. 5.2.2 Physical Presence Administrative operations to the TPM require TPM ownership or physical presence indication by the operator to confirm the execution of administrative operations. The BIOS implements the operator presence indication by verifying the setup Administrator password. A TPM administrative sequence invoked from the operating system proceeds as follows: 1. User makes a TPM administrative request through the operating system's security software. 2. The operating system requests the BIOS to execute the TPM administrative command through TPM ACPI methods and then resets the system. 3. The BIOS verifies the physical presence and confirms the command with the operator. 4. The BIOS executes TPM administrative command(s), inhibits BIOS Setup entry and boots directly to the operating system which requested the TPM command(s). 5.2.3 TPM Security Setup Options The BIOS TPM Setup allows the operator to view the current TPM state and to carry out rudimentary TPM administrative operations. Performing TPM administrative options through the BIOS setup requires TPM physical presence verification. Using BIOS TPM Setup, the operator can turn ON or OFF TPM functionality and clear the TPM ownership contents. After the requested TPM BIOS Setup operation is carried out, the option reverts to No Operation. The BIOS TPM Setup also displays the current state of the TPM, whether TPM is enabled or disabled and activated or deactivated. Note that while using TPM, a TPM-enabled operating system or application may change the TPM state independent of the BIOS setup. When an operating system modifies the TPM state, the BIOS Setup displays the updated TPM state. The BIOS Setup TPM Clear option allows the operator to clear the TPM ownership key and allows the operator to take control of the system with TPM. You use this option to clear security settings for a newly initialized system or to clear a system for which the TPM ownership security key was lost. 5.2.3.1 Security Screen To enter the BIOS Setup, press the F2 function key during boot time when the OEM or Intel logo displays. The following message displays on the diagnostics screen and under the Quiet Boot logo screen: Press to enter setup When the Setup is entered, the Main screen displays. The BIOS Setup utility provides the Security screen to enable and set the user and administrative passwords and to lock out the front panel buttons so they cannot be used. The Intel(R) Server Board S5520URT provides TPM settings through the security screen. To access this screen from the Main screen, select the Security option. Revision 1.2 Intel order number G34153-003 85 System Security Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Main Advanced Main Advanced Security Server Management Administrator Password Status User Password Status Set Administrator Password [1234aBcD] Set User Password [1234aBcD] Front Panel Lockout Enabled/Disabled TPM State TPM Administrative Control Boot Options Boot Manager No Operation/Turn On/Turn Off/Clear Ownership Figure 26. Setup Utility - TPM Configuration Screen Table 28. TSetup Utility - Security Configuration Screen Fields Setup Item TPM State* Options Enabled and Activated Enabled and Deactivated Disabled and Activated Disabled and Deactivated Help Text Comments Information only. Shows the current TPM device state. A disabled TPM device will not execute commands that use TPM functions and TPM security operations will not be available. An enabled and deactivated TPM is in the same state as a disabled TPM except setting of TPM ownership is allowed if not present already. An enabled and activated TPM executes all commands that use TPM functions and TPM security operations will be available. TPM Administrative Control** 86 No Operation Turn On Turn Off Clear Ownership [No Operation] - No changes to current state. [Turn On] - Enables and activates TPM. [Turn Off] - Disables and deactivates TPM. Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Setup Item 5.3 Options Help Text [Clear Ownership] - Removes the TPM ownership authentication and returns the TPM to a factory default state. Note: The BIOS setting returns to [No Operation] on every boot cycle by default. System Security Comments Intel(R)Trusted Execution Technology The Intel(R) Xeon(R) Processor E5-4600/2600/2400/1600 Product Families support Intel(R) Trusted Execution Technology (Intel(R) TXT), which is a robust security environment. Designed to help protect against software-based attacks, Intel(R) Trusted Execution Technology integrates new security features and capabilities into the processor, chipset and other platform components. When used in conjunction with Intel(R) Virtualization Technology, Intel(R) Trusted Execution Technology provides hardware-rooted trust for your virtual applications. This hardware-rooted security provides a general-purpose, safer computing environment capable of running a wide variety of operating systems and applications to increase the confidentiality and integrity of sensitive information without compromising the usability of the platform. Intel(R) Trusted Execution Technology requires a computer system with Intel(R) Virtualization Technology enabled (both VT-x and VT-d), an Intel(R) Trusted Execution Technology-enabled processor, chipset and BIOS, Authenticated Code Modules, and an Intel(R) Trusted Execution Technology compatible measured launched environment (MLE). The MLE could consist of a virtual machine monitor, an OS or an application. In addition, Intel(R) Trusted Execution Technology requires the system to include a TPM v1.2, as defined by the Trusted Computing Group TPM PC Client specifications, Revision 1.2. When available, Intel Trusted Execution Technology can be enabled or disabled in the processor by a BIOS Setup option. For general information about Intel(R) TXT, visit the Intel(R) Trusted Execution Technology website, http://www.intel.com/technology/security/. Revision 1.2 Intel order number G34153-003 87 Connector/Header Locations and Pin-outs Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 6. Connector/Header Locations and Pin-outs 6.1 Power Connectors 6.1.1 Main Power Connector Main server board power is supplied by one 12-pin power connector. The connector is labeled as "MAIN PWR" on the left bottom of the server board. The following tables provide the pin-out for "MAIN PWR" connector. Table 29. Main Power Connector Pin-out Pin 1 2 3 4 5 6 7 8 9 10 11 12 6.1.2 Signal name P3V3 P3V3 GND P5V GND P5V GND PWRGD_PS_PWROK_PSU_R1 P5V_STBY_PSU P12V P12V P3V3 Pin 13 14 15 16 17 18 19 20 21 22 23 24 Signal name P3V3 N12V GND FM_PS_EN_PSU_N GND GND GND NC_PS_RES_TP P5V P5V P5V GND CPU Power Connectors On the server board are two white 8-pin CPU power connectors labeled "CPU_1 PWR" and "CPU_2 PWR". The following table provides the pin-out for both connectors. Table 30. CPU_1 Power Connector Pin-out Pin 1 2 3 4 Signal name GND GND GND GND Pin 5 6 7 8 Signal name P12V1 P12V1 P12V3A P12V3A Table 31. CPU_2 Power Connector Pin-out Pin 1 2 3 4 6.1.3 Signal name GND GND GND GND Pin 5 6 7 8 Signal name P12V2 P12V2 P12V3B P12V3B Add-in Card Power Connectors The serve board includes white 2x2-pin power connectors that provide supplemental power to high power PCIe x16 add-in cards (Video or GPGPU) that have power requirements that exceed the maximum power supplied by the riser slot. A cable from this connector may be routed to a matching connector on a riser card designed to support it or directly to the add-in cards that need them. Available power to each of these connectors is limited by the amount of 88 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Connector/Header Locations and Pin-outs power provided by the power supply and the total power draw for the rest of the system. A power budget for the complete system should be performed to determine how much supplemental power is available to support any high power add-in cards. Each connector is labeled as "OPT_12V_PWR" on the server board. The following table provides the pin-out for both connectors. Table 32. Add-in Slot Power Pin-input ("OPT_12V_PWR") Pin 1 2 6.2 Signal Name GND GND Pin 3 4 Signal Name +12V +12V Front Panel Header and Connectors The server board includes several connectors that provide various possible front panel options. This section provides a functional description and pin-out for each connector. 6.2.1 Front Panel Header Included on the left edge of the server board is a 30-pin header consists of a 24-pin SSI compatible front panel header and a 4-pin header to support optional NIC3/4 LEDs. The 24-pin SSI front panel header provides various front panel features including: Power/Sleep Button System ID Button NMI Button NIC Activity LEDs Hard Drive Activity LEDs System Status LED System ID LED The following table provides the pin-out for this 30-pin header. Table 33. Front Panel Header Pin-out Pin 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 Revision 1.2 Signal name P3V3_AUX Key FP_PWR_LED_BUF_N P3V3 LED_HDD_ACTIVITY_N FP_PWR_BTN_N GND FP_RST_BTN_N GND FP_ID_BTN_N PU_FM_SIO_TEMP_SENSOR FP_NMI_BTN_N LED_NIC_LINK2_ACT_FP_N LED_NIC_LINK2_LNKUP_FP_N Pin 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Signal name P3V3_AUX P5V_STBY FP_ID_LED_BUF_N FP_LED_STATUS_GREEN_BUF_N FP_LED_STATUS_AMBER_BUF_N LED_NIC_LINK0_ACT_BUF_N LED_NIC_LINK0_LNKUP_BUF_N SMB_SENSOR_3V3STBY_DATA SMB_SENSOR_3V3STBY_CLK FP_CHASSIS_INTRUSION LED_NIC_LINK1_ACT_BUF_N LED_NIC_LINK1_LNKUP_BUF_N LED_NIC_LINK3_ACT_FP_N LED_NIC_LINK3_LNKUP_FP_N Intel order number G34153-003 89 Connector/Header Locations and Pin-outs 6.2.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Front Panel USB Connector The server board includes a 10-pin connector, that when cabled, can provide up to two USB ports to a front panel. The following table provides the connector pin-out. Table 34. Front Panel USB Connector Pin-out Pin 1 3 5 7 9 6.2.3 Signal Name P5V_USB_FP USB2_P13_F_DN USB2_P13_F_DP GND KEY Pin 2 4 6 8 10 Signal Name P5V_USB_FP USB2_P11_F_DN USB2_P11_F_DP GND NA Local Control Panel Connector The server board includes a 7-pin connector that is used when the system is configured with the Intel Local Control Panel with LCD support. The following table provides the pin-out for this connector. Table 35. Local Front Panel Connector Pin-out Pin 1 3 5 7 6.3 Signal Name SMB_SENSOR_3V3STBY_DATA SMB_SENSOR_3V3STBY_CLK FM_LCP_ENTER_N FM_LCP_RIGHT_N Pin 2 4 6 Signal Name GND P3V3_AUX FM_LCP_LEFT_N On Board Storage Connectors The server board provides connectors for support of several storage device options. This section provides a functional overview and pin-out of each connector. 6.3.1 SATA Connectors: 6Gbps The board includes two white single port SATA only connectors capable of transfer rates of up to 6Gb/s. The following table provides the pin-out for both connectors. Table 36. SATA 6Gbps Connector Pin-out Pin 1 2 3 4 5 6 7 90 Signal Name GND SATA_TX_P SATA_TX_N GND SATA_RX_N SATA_RX_P GND Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 6.3.2 Connector/Header Locations and Pin-outs Multiport Mini-SAS/SATA Connectors The board includes two 40-pin high density multiport mini-SAS/SATA connectors. On the board, these connectors are labeled as "SCU0 port(0-3)" supporting the chipset embedded SCU0 controller, and "SCU1 Port(4-7)", supporting the embedded SCU1 controller. Both connectors can support up to four SATA or SAS ports each. By default, only the connector labeled "SCU0 Port(0-3)" is enabled and has support for up to four SATA ports capable. The connector labeled "SCU1 Port(4-7)" is only enabled when an optional 8-port SAS or SATA Intel(R) RAID C600 Upgrade Key is installed. The following tables provide the pin-out for each connector. Table 37. Multiport SAS/SATA Connector Pin-out ("SCU_0 (0-3)") Pin A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 MTH1 MTH2 MTH3 MTH4 Signal name GROUND SAS0_RX_C_DP SAS0_RX_C_DN GROUND SAS1_RX_C_DP SAS1_RX_C_DN GROUND TP_SAS1_BACKPLANE_TYPE GROUND SGPIO_SAS1_DATAOUT SGPIO_SAS1_DATAIN GROUND SAS2_RX_C_DP SAS2_RX_C_DN GROUND SAS3_RX_C_DP SAS3_RX_C_DN GROUND GROUND GROUND GROUND GROUND Pin B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 MTH5 MTH6 MTH7 MTH8 Signal name GROUND SAS0_TX_C_DP SAS0_TX_C_DN GROUND SAS1_TX_C_DP SAS1_TX_C_DN GROUND SGPIO_SAS1_CLOCK SGPIO_SAS1_LOAD GROUND PD_SAS1_CONTROLLER_TYPE GROUND SAS2_TX_C_DP SAS2_TX_C_DN GROUND SAS3_TX_C_DP SAS3_TX_C_DN GROUND GROUND GROUND GROUND GROUND Table 38. Multiport SAS/SATA Connector Pin-out ("SCU_1 (4-7)") Pin A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 Revision 1.2 Signal name GROUND SAS4_RX_C_DP SAS4_RX_C_DN GROUND SAS5_RX_C_DP SAS5_RX_C_DN GROUND TP_SAS2_BACKPLANE_TYPE GROUND SGPIO_SAS2_DATAOUT SGPIO_SAS2_DATAIN GROUND SAS6_RX_C_DP Pin B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 Signal name GROUND SAS4_TX_C_DP SAS4_TX_C_DN GROUND SAS5_TX_C_DP SAS5_TX_C_DN GROUND SGPIO_SAS2_CLOCK SGPIO_SAS2_LOAD GROUND PD_SAS2_CONTROLLER_TYPE GROUND SAS6_TX_C_DP Intel order number G34153-003 91 Connector/Header Locations and Pin-outs Pin A14 A15 A16 A17 A18 MTH1 MTH2 MTH3 MTH4 6.3.3 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Signal name SAS6_RX_C_DN GROUND SAS7_RX_C_DP SAS7_RX_C_DN GROUND GROUND GROUND GROUND GROUND Pin B14 B15 B16 B17 B18 MTH5 MTH6 MTH7 MTH8 Signal name SAS6_TX_C_DN GROUND SAS7_TX_C_DP SAS7_TX_C_DN GROUND GROUND GROUND GROUND GROUND Intel(R)RAID C600 Upgrade Key Connector The server board provides one connector to support Intel(R) RAID C600 Upgrade Key. The Intel(R) RAID C600 Upgrade Key is a small PCB board that enables different versions of RAID 5 software stack and/or upgrade from SATA to SAS storage functionality. The pin configuration of connector is identical and defined in the following table. Table 39. Intel(R) RAID C600 Upgrade Key Connector Pin-out Pin 1 2 3 4 6.3.4 Signal Name GND FM_PBG_DYN_SKU_KEY GND FM_SSB_SAS_SATA_RAID_KEY HSBP_I2C Header Table 40. HSBP_I2C Header Pin-out Pin 1 2 3 6.3.5 Signal Name SMB_HSBP_3V3STBY_DATA GND SMB_HSBP_3V3STBY_CLK HDD LED Header The server board includes a 2-pin hard drive activity LED header used with some SAS/SATA controller add-in cards. The header has the following pin-out. Table 41. HDD LED Header Pin-out Pin 1 6.3.6 Signal Name LED_HDD_ACT_N Pin 2 Signal Name NA Internal Type- A USB Connector The server board includes two internal Type-A USB connector. The following table provides the pin-out for this connector. Table 42. Type-A USB Connector Pin-out Pin 1 3 92 Signal Name P5V USB2_P2_F_DP Pin 2 4 Signal Name USB2_P2_F_DN GND Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 6.3.7 Connector/Header Locations and Pin-outs Internal eUSB SSD Header The server board includes one 10-pin internal eUSB header with an intended usage of supporting USB SSD devices. The following table provides the pin-out for this connector. Table 43. eUSB SSD Header Pin-out Pin 1 3 5 7 9 6.4 Signal Name 5V USB2_P0_DN USB2_P0_DP GND Key Pin 2 4 6 8 10 Signal Name NC NC NC NC LED_HDD_ACT_ZEPHER_N Management and Security Connectors 6.4.1 RMM4_Lite Connector A 7-pin Intel RMM4 Lite connector is included on the server board to support the optional Intel(R) Remote Management Module 4. There is no support for third-party management cards on this server board. (R) Table 44. RMM4_Lite Connector Pin-out Pin 1 3 5 7 6.4.2 Signal Name P3V3_AUX KEY DO CS_N Pin 2 4 6 8 Signal Name DI CLK GND GND RMM4_NIC Connector Table 45. RMM4_NIC Connector Pin-out Revision 1.2 Pin 1 3 5 7 9 11 13 15 17 19 21 23 Signal Name 3V3_AUX 3V3_AUX GND GND GND GND GND GND GND GND GND GND Pin 2 4 6 8 10 12 14 16 18 20 22 24 Signal Name MDIO MDC TXD_0 TXD_1 TXD_2 TXD_3 TX_CTL RX_CTL RXD_0 RXD_1 RXD_2 RXD_3 25 GND 26 TX_CLK 27 29 GND GND 28 30 RX_CLK PRESENT# Intel order number G34153-003 93 Connector/Header Locations and Pin-outs 6.4.3 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS TPM Connector Table 46. TPM Connector Pin-out Pin 1 3 5 7 9 11 13 6.4.4 Signal Name Key LPC_LAD<0> IRQ_SERIAL P3V3 RST_IBMC_NIC_N_R2 LPC_LAD<3> GND Pin 2 4 6 8 10 12 14 Signal Name LPC_LAD<1> GND LPC_FRAME_N GND CLK_33M_TPM GND LPC_LAD<2> PMBus* Connector Table 47. PMBus* Connector Pin-out Pin 1 2 3 4 5 6.4.5 Signal name SMB_PMBUS_CLK_R SMB_PMBUS_DATA_R IRQ_SML1_PMBUS_ALERT_RC_N GND P3V3 Chassis Intrusion Header The server board includes a 2-pin chassis intrusion header which can be used when the chassis is configured with a chassis intrusion switch. The header has the following pin-out. Table 48. Chassis Intrusion Header Pin-out Header State Pins 1 and 2 closed Pins 1 and 2 open 6.4.6 Description FM_INTRUDER_HDR_N is pulled HIGH. Chassis cover is closed. FM_INTRUDER_HDR_N is pulled LOW. Chassis cover is removed. IPMB Connector Table 49. IPMB Connector Pin-out Pin 1 2 3 4 6.5 Signal Name SMB_IPMB_5VSTBY_DATA GND SMB_IPMB_5VSTBY_CLK P5V_STBY FAN Connectors The server board provides support for nine fans. Seven of them are system cooling fans, two of them are CPU fans. 94 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 6.5.1 Connector/Header Locations and Pin-outs System FAN Connectors The six system cooling fan connectors near the front edge of the board are 6-Pin connectors; the one system cooling fan near edge of the board is a 4-Pin connectors. Following table provides the pin-out for all system fan connectors. Table 50. 6-pin System FAN Connector Pin-out Pin 1 2 3 4 5 6 Signal Name GND 12V TACH PWM PRSNT FAULT Table 51. 4-pin System FAN Connector Pin-out Pin 1 2 3 4 6.5.2 Signal Name GND 12V TACH PWM CPU FAN Connector The two CPU fan connectors are 4-pin fan connectors. Following table provides the pin-out for CPU fan connectors. Table 52. CPU FAN Connector Pin-out Pin 1 2 3 4 6.6 Signal Name GND 12V TACH PWM Serial Port and Video Connectors The server board includes two serial port connectors. 6.6.1 Serial Port A Connector (DB9, for Intel(R) Server Board S2600IP only) Serial-A is an external RJ45 type connector and has the following pin-out configuration. Table 53. Serial Port A Connector Pin-out Pin 1 3 5 7 9 Revision 1.2 Signal Name SPA_DCD SPA_SOUT_N GND SPA_RTS SPA_RI Pin 2 4 6 8 Signal Name SPA_SIN SPA_DTR SPA_DSR SPA_CTS Intel order number G34153-003 95 Connector/Header Locations and Pin-outs 6.6.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Serial Port B Connector Serial-B is an internal 10-pin DH-10 connector and has the following pin-out. Table 54. Serial Port B Connector Pin-out Pin 1 3 5 7 9 6.6.3 Signal Name SPA_DCD SPA_SIN SPA_SOUT_N SPA_DTR GND Pin 2 4 6 8 Signal Name SPA_DSR SPA_RTS SPA_CTS SPA_RI Video Connector (For Intel(R) Server Board S2600IP only) The following table details the pin-out definition of the external VGA connector. Table 55. Video Connector Pin-out details Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Signal Name CRT_RED CRT_GREEN CRT_BLUE N/C GND GND GND GND P5V GND NC CRT_DDCDATA CRT_HSYNC CRT_VSYNC CRT_DDCCLK Figure 27. Video Connector Pin-out 96 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 6.6.4 Connector/Header Locations and Pin-outs Internal Video header (For Intel(R) Workstation Board W2600CR only) Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Signal Name CRT_RED GND CRT_Green GND CRT_Blue GND CRT_VSYNC GND CRT_HSYN Key CRT_DDCDATA VIDEO_IN_USE signal CRT_DDCCLK 5V Note: Intel(R) Corporation server boards support peripheral components and can contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel(R) developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits. Revision 1.2 Intel order number G34153-003 97 Jumper Blocks 7. Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Jumper Blocks The server boards have several 3-pin jumper blocks that you can use to configure, protect, or recover specific features of the server boards. The following symbol identifies Pin 1 on each jumper block on the silkscreen: Figure 28. Jumper Blocks (J1C3, J1F1, J1F2, J2F3, J2F2) Table 56. Server Board Jumpers (J1C3, J1F1, J1F2, J2F3, J2F2) Jumper Name J1F2: BIOS Recovery J1F1: Bios Default (CMOS Clear) J2F2: 98 ME Force Pins System Results 1-2 Pins 1-2 should be connected for normal system operation. (Default) The main system BIOS does not boot with pins 2-3 connected. The system only boots from EFI-bootable recovery media with a recovery BIOS image present. These pins should have a jumper in place for normal system operation. (Default) If pins 2-3 are connected when AC power unplugged, the CMOS settings clear in 5 seconds. Pins 2-3 should not be connected for normal system operation. ME Firmware Force Update Mode - Disabled (Default) 2-3 1-2 2-3 1-2 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Jumper Blocks Jumper Name Pins System Results Update 2-3 1-2 2-3 ME Firmware Force Update Mode - Enabled BMC Firmware Force Update Mode - Disabled (Default) BMC Firmware Force Update Mode - Enabled These pins should have a jumper in place for normal system operation. (Default) To clear administrator and user passwords, power on the system with pins 2-3 connected. The administrator and user passwords clear in 5-10 seconds after power on. Pins 2-3 should not be connected for normal system operation. J1C1: BMC Update Force 1-2 J2F3: Password Clear 2-3 7.1 BIOS Default and Password Reset Usage Procedure The BIOS Default (CMOS Clear) and Password Reset recovery features are designed to achieve the desired operation with minimum system down time. The usage procedure for these two features has changed from previous generation Intel(R) boards. The following procedure outlines the new usage model. 7.1.1 Set BIOS to default (Clearing the CMOS) 1. Power down the server and unplug the AC power cord. 2. Open the server chassis. For instructions, see your server chassis documentation. 3. Move the jumper from the default operating position (covering pins 1 and 2) to the reset/clear position (covering pins 2 and 3). 4. Wait five seconds. 5. Move the jumper back to the default position, covering pins 1 and 2. 6. Close the server chassis and reconnect the AC power cord. 7. Power up the server. The CMOS is now cleared and you can reset it by going into the BIOS setup. Note: Removing AC power before performing the CMOS clear operation causes the system to automatically power up and immediately power down, after the procedure is followed and AC power is re-applied. If this happens, remove the AC power cord again, wait 30 seconds, and reinstall the AC power cord. Power up the system and proceed to the BIOS Setup utility to reset the preferred settings. 7.1.2 Clearing the Password 1. Power down the server. Do not unplug the power cord. 2. Open the chassis. For instructions, see your server chassis documentation. 3. Move the jumper from the default operating position (covering pins 1 and 2) to the password clear position (covering pins 2 and 3). 4. Close the server chassis. 5. Power up the server and then press to enter the BIOS menu to check if the password is cleared. 6. Power down the server. Revision 1.2 Intel order number G34153-003 99 Jumper Blocks Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 7. Open the chassis and move the jumper back to its default position (covering pins 1 and 2). 8. Close the server chassis. 9. Power up the server. The password is now cleared and you can reset it by going into the BIOS setup. 7.2 Force BMC Update Procedure When performing a standard BMC firmware update procedure, the update utility places the BMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event the BMC firmware update process fails due to the BMC not being in the proper update state, the server boards provide a Force BMC Update jumper that forces the BMC into the proper update state. In the event the standard BMC firmware update process fails, complete the following procedure: 1. Power down and remove the AC power cord. 2. Open the server chassis. See your server chassis documentation for instructions. 3. Move the jumper from the default operating position (covering pins 1 and 2) to the enabled position (covering pins 2 and 3). 4. Close the server chassis. 5. Reconnect the AC power cord and power up the server. 6. Perform the BMC firmware update procedure as documented in the BMC firmware update package. After successful completion of the firmware update process, the firmware update utility may generate an error stating the BMC is still in update mode. 7. Power down and remove the AC power cord. 8. Open the server chassis. 9. Move the jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering pins 1 and 2). 10. Close the server chassis. 11. Reconnect the AC power cord and power up the server. Note: When the Force BMC Update jumper is set to the enabled position, normal BMC functionality is disabled. You should never run the server with the Force BMC Update jumper set in this position. You should only use this jumper setting when the standard firmware update process fails. When the server is running normally, this jumper must remain in the default/disabled position. 7.3 BIOS Recovery Jumper The following procedure boots the recovery BIOS and flashes the normal BIOS: 1. Turn off the system power. 2. Move the BIOS recovery jumper to the recovery state. 3. Insert a bootable BIOS recovery media containing the new BIOS image files. 4. Turn on the system power. 100 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Jumper Blocks The BIOS POST screen will appear displaying the progress, and the system will boot to the EFI shell. The EFI shell then executes the Startup.nsh batch file to start the flash update process. The user should then switch off the power and return the recovery jumper to its normal position. The user should not interrupt the BIOS POST on the first boot after recovery. When the flash update completes: 1. Remove the recovery media. 2. Turn off the system power. 3. Restore the jumper to its original position. 4. Turn on the system power. 5. Re-flash any custom blocks, such as user binary or language blocks. The system should now boot using the updated system BIOS. 7.4 ME Force Update Jumper When performing the standard ME force update procedure, the update utility places the ME into an update mode, allowing the ME to load safely onto the flash device. In the unlikely event ME firmware update process fails due to ME not being in the proper update state, the server board provides an Integrated BMC Force Update jumper, which forces the ME into the proper update state. The following procedure should be completed in the event the standard ME firmware update process fails. 1. Power down and remove the AC power cord. 2. Open the server chassis. For instructions, see your server chassis documentation. 3. Move jumper from the default operating position (covering pins 1 and 2) to the enabled position (covering pins 2 and 3). 4. Close the server chassis. 5. Reconnect the AC cord and power up the server. 6. Perform the ME firmware update procedure as documented in the README.TXT file that is included in the given ME firmware update package (same package as BIOS). 7. Power down and remove the AC power cord. 8. Open the server chassis. 9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering pins 1 and 2). 10. Close the server chassis. 11. Reconnect the AC cord and power up the server. Revision 1.2 Intel order number G34153-003 101 Intel(R)Light Guided Diagnostics 8. Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Intel(R)Light Guided Diagnostics Both server boards have several onboard diagnostic LEDs to assist in troubleshooting board-level issues. This section provides a description of the location and function of each LED on the server boards. 8.1 5-volt Stand-by LED Several server management features of these server boards require a 5-V stand-by voltage supplied from the power supply. The features and components that require this voltage must be present when the system is "power-down". The LED is illuminated when AC power is applied to the platform and 5-V standby voltage is supplied to the server board by the power supply. 8.2 Fan Fault LED Fan fault LEDs are present for the two CPU fans and the one rear system fan. The fan fault LEDs illuminate when the corresponding fan has fault. 8.3 CPU Fault LED CPU fault LED should correspond to the socket with the failed or disabled CPU. The CPU LEDs illuminate when CPU failure or Disable. 102 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Intel(R)Light Guided Diagnostics Figure 29. Stand by LED, Fan Fault LED and CPU Fault LED Location Revision 1.2 Intel order number G34153-003 103 Intel(R)Light Guided Diagnostics 8.4 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS DIMM Fault LEDs The server board provide memory fault LED for each DIMM socket. These LEDs are located as shown in the following figure. The DIMM fault LED illuminates when the corresponding DIMM slot has memory installed and a memory error occurs. Figure 30. DIMM Fault LED's Location 8.5 System ID LED, System Status LED and POST Code Diagnostic LEDs The server boards provide LEDs for system ID, system status and POST code. These LEDs are located in the rear I/O area of the server board as shown in the following figure. 104 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Intel(R)Light Guided Diagnostics Figure 31. Location of System Status, System ID and POST Code Diagnostic LEDs LED Name 8.5.1 Description A System Status LED B System ID LED LSB 1 2 3 4 5 6 MSB Post Code Diagnostic LEDs System ID LED You can illuminate the blue System ID LED using either of the following two mechanisms: By pressing the System ID Button on the system front control panel, the ID LED displays a solid blue color until the button is pressed again. By issuing the appropriate hex IPMI "Chassis Identify" value, the ID LED will either blink blue for 15 seconds and turn off or will blink indefinitely until the appropriate hex IPMI Chassis Identify value is issue to turn it off. Revision 1.2 Intel order number G34153-003 105 Intel(R)Light Guided Diagnostics 8.5.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS System Status LED The bi-color (green/amber) System Status LED operates as follows: Table 57. System Status LED Color Green State Solid on Criticality Ok Green ~1 Hz blink Degraded Amber ~1 Hz blink Non-critical 106 Description Indicates that the System Status is `Healthy'. The system is not exhibiting any errors. AC power is present and BMC has booted and manageability functionality is up and running. System degraded: 1. Redundancy loss such as power-supply or fan. Applies only if the associated platform sub-system has redundancy capabilities. 2. Fan warning or failure when the number of fully operational fans is more than minimum number needed to cool the system. 3. Non-critical threshold crossed - Temperature (including HSBP temp), voltage, input power to power supply, output current for main power rail from power supply and Processor Thermal Control (Therm Ctrl) sensors. 4. Power supply predictive failure occurred while redundant power supply configuration was present. 5. Unable to use all of the installed memory (more than 1 DIMM installed). 6. Correctable Errors over a threshold and migrating to a spare DIMM (memory sparing). This indicates that the user no longer has spared DIMMs indicating a redundancy lost condition. Corresponding DIMM LED lit. 7. In mirrored configuration, when memory mirroring takes place and system loses memory redundancy. 8. Battery failure. 9. BMC executing in uBoot. (Indicated by Chassis ID blinking at Blinking at 3Hz). System in degraded state (no manageability). BMC uBoot is running but has not transferred control to BMC Linux. Server will be in this state 68 seconds after BMC reset while it pulls the Linux image into flash 10. BMC booting Linux. (Indicated by Chassis ID solid ON). System in degraded state (no manageability). Control has been passed from BMC uBoot to BMC Linux itself. It will be in this state for ~10-~20 seconds. 11. BMC Watchdog has reset the BMC. 12. Power Unit sensor offset for configuration error is asserted. 13. HDD HSC is off-line or degraded. Non-fatal alarm - system is likely to fail: 1. Critical threshold crossed - Voltage, temperature (including HSBP temp), input power to power supply, output current for main power rail from power supply and PROCHOT (Therm Ctrl) sensors. 2. VRD Hot asserted. 3. Minimum number of fans to cool the system not present or failed 4. Hard drive fault 5. Power Unit Redundancy sensor - Insufficient resources offset (indicates not enough power supplies present). 6. In non-sparing and non-mirroring mode if the threshold of correctable errors is crossed within the window Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Intel(R)Light Guided Diagnostics Color Amber State Solid on Criticality Critical, nonrecoverable Description Fatal alarm - system has failed or shutdown: 1. CPU CATERR signal asserted. 2. MSID mismatch detected (CATERR also asserts for this case). 3. CPU 1 is missing. 4. CPU ThermalTrip. 5. No power good - power fault. 6. DIMM failure when there is only 1 DIMM present and hence no good memory present. 7. Runtime memory uncorrectable error in non-redundant mode 1. 8. DIMM Thermal Trip or equivalent. 9. SSB Thermal Trip or equivalent. 10. CPU ERR2 signal asserted. 11. BMC/Video memory test failed. (Chassis ID shows blue/solid-on for this condition). 12. Both uBoot BMC FW images are bad. (Chassis ID shows blue/solid on for this condition). 13. 13. 240VA fault Off N/A Not ready AC power off 8.5.3 POST Code Diagnostic LEDs During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the given POST code to the POST code diagnostic LED's on the back edge of the server boards. To assist in troubleshooting a system hang during the POST process, you can use the diagnostic LEDs to identify the last POST process executed. Table 58. POST Code Diagnostic LEDs A. Diagnostic LED #7 (MSB LED) E. Diagnostic LED #3 B. Diagnostic LED #6 F. Diagnostic LED #2 C. Diagnostic LED #5 G. Diagnostic LED #1 D. Diagnostic LED #4 H. Diagnostic LED #0 (LSB LED) Revision 1.2 Intel order number G34153-003 107 Design and Environmental Specifications Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 9. Design and Environmental Specifications 9.1 Products Design Specifications The following table defines the Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR operating and non-operating environmental limits. Operation of the Intel(R) Server Board S2600IP and Intel(R) Workstation Board W2600CR at conditions beyond those shown in the following table may cause permanent damage to the system. Exposure to absolute maximum rating conditions for extended periods may affect system reliability. Table 59. Server Board Design Specifications 0C to 55C 1 (32F to 131F) Operating Temperature -40C to 70C (-40F to 158F) Non-Operating Temperature 5% of all nominal voltages DC Voltage Trapezoidal, 35g , 170 inches/sec Shock (Unpackaged) Shock (Packaged) < 20 pounds 36 inches 20 to < 40 pounds 30 inches 40 to < 80 pounds 24 inches 80 to < 100 pounds 18 inches 100 to < 120 pounds 12 inches 120 pounds 9 inches 5 Hz to 500 Hz 3.13 g RMS random Vibration (Unpackaged) Note: 1. Intel Corporation server boards contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel(R) server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel(R) developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits. Disclaimer Note: Intel(R) ensures the unpackaged server board and system meet the shock requirement mentioned above through its own chassis development and system configuration. It is the responsibility of the system integrator to determine the proper shock level of the board and system if the system integrator chooses different system configuration or different chassis. Intel Corporation cannot be held responsible, if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits. 9.2 MTBF The following is the calculated Mean Time Between Failures (MTBF) 30 C (ambient air). These values are derived using a historical failure rate and multiplied by factors for application, electrical and/or thermal stress and for device maturity. You should view MTBF estimates as "reference numbers" only. 108 Calculation Model: Telcordia* Issue 2, method I case 3 Operating Temperature: Server in 30C ambient air Operating Environment: Ground Benign, Controlled Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Design and Environmental Specifications Duty Cycle: 100% Quality Level: II Table 60. Intel(R) Server Board S2600IP MTBF Estimate Assembly Name Failure Rate MTBF Mother Board 4,981.828605 200,730 Integrated Circuits 888.017556 1,126,104 Transistor_Bipolar 142.288706 7,027,965 Transistor_MOSFET 394.540757 2,534,592 Diodes 24.364143 41,043,923 Diodes_LED 30.002406 33,330,661 Resistors 1,134.467959 881,470 Capacitors 379.972284 2,631,771 Cap, Al Elect 741.486991 1,348,641 Inductors 148.990773 6,711,825 Connections 1,213.354514 824,161 Misc 94.901757 10,537,213 Table 61. Intel(R) Workstation Board W2600CR MTBF Estimate Assembly Name Revision 1.2 Failure Rate MTBF Mother Board 5,247.668190 190,561 Integrated Circuits 951.031471 1,051,490 Transistor_Bipolar 147.372000 6,785,549 Transistor_MOSFET 404.110588 2,474,570 Diodes 36.808324 27,167,768 Diodes_LED 30.002406 33,330,661 Resistors 1,204.023273 830,549 Capacitors 413.065171 2,420,925 Cap, Al Elect 770.924084 1,297,145 Inductors 175.282101 5,705,089 Connections 1,216.849949 821,794 Intel order number G34153-003 109 Design and Environmental Specifications Assembly Name Misc 110 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Failure Rate 127.585507 Intel order number G34153-003 MTBF 7,837,881 Revision 1.2 Intel(R)Server Board S5520HC / S5500HCV TPS 9.3 Design and Environmental Specifications Server Board Power Requirements This section provides power supply design guidelines for a system using the Intel(R) Server Board S2600IP and Workstation Board W2600CR including voltage and current specifications, and power supply on/off sequencing characteristics. The following diagram shows the power distribution implemented on these server boards. Figure 32. Power Distribution Block Diagram Revision 1.2 Intel order number G34153-003 111 Appendix A: Integration and Usage Tips 9.3.1 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Processor Power Support The server boards support the Thermal Design Power (TDP) guideline for Intel(R) Xeon(R) processors. The Flexible Motherboard Guidelines (FMB) is followed to determine the suggested thermal and current design values for anticipating future processor needs. The following table provides maximum values for DTS, TDP power and TCASE for the compatible Intel(R) E5-2600 processor family series. Table 62. Intel(R) Xeon(R) Processor Dual Processor TDP profile Max TDP Power Max Tcase ( C) Max DTS ( C) 130W 85C 104.4 for 6 core 100 for 8 core 150W 9.4 67C 84.8 Power Supply Output Requirements This section is for reference purposes only. The intent is to provide guidance to system designers to determine a power supply to use with these server boards. This section specifies the power supply requirements Intel used to develop a power supply for its server system. 9.4.1 Output Power/Currents The following tables define the minimum power and current ratings. The power supply must meet both static and dynamic voltage regulation requirements for all conditions. Table 63. Minimum Load Ratings Parameter 3.3V 5V 12V1 12V2 12V3 12V 5Vstby Min 0.5 0.3 0.7 0.7 1.5 0.0 0.0 Max. 18.0 15.0 24.0 24.0 18.0 0.5 3.0 Peak 28.0 28.0 3.5 Unit A A A A A A A Notes: 1. 2. 3. 4. 9.4.2 Combined continuous power for all output shall not exceed 550W. Peak combined power for all outputs shall not exceed 630W for 20 seconds. Max combined power of 12V1, 12V2, and 12V3 shall not exceed 530W. Max combined power on 3.3V and 5V shall not exceed 120W. Cross Loading The power supply shall maintain voltage regulation limit when operated over the following cross loading conditions. 112 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix A: Integration and Usage Tips Table 64. Loading Conditions 3.3V 5V 12V1 12V2 12V3 -12V 5Vstby Total Power 12V Power 3.3V/5V Power Load1 18 12.1 12 12 11.7 0 0.3 550 428 120 Load2 13.5 15 12 12 11.2 0.5 0.3 549 422 120 Load3 2.5 2 20 20 4.2 0 0.3 550 530 18 Load4 2.5 2 13.1 13.1 18 0 0.3 550 530 18 Load5 0.5 0.3 15 15 6.5 0.5 3 462 438 3 Load6 16 4 1 1 3.5 0 0.3 140 66 73 Load7 16 13 1 1 9 0.5 3 271 132 118 9.4.3 Standby Output The 5VSB output shall be present when an AC input greater than the power supply turn on voltage is applied. 9.4.4 Voltage Regulation The power supply output voltages must stay within the following voltage limits when operating at steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise. These shall be measured at the output connectors. Table 65.Voltage Regulation Limits Parameter +3.3V +5V +12V1 +12V2 +12V3 - 12V +5VSB 9.4.5 Tolerance - 3%/+5% - 4%/+5% - 4%/+5% - 4%/+5% - 4%/+5% - 10%/+10% - 4%/+5% Min +3.20 +4.80 +11.52 +11.52 +11.52 - 13.20 +4.80 Nom +3.30 +5.00 +12.00 +12.00 +12.00 -12.00 +5.00 Max +3.46 +5.25 +12.60 +12.60 +12.60 -10.80 +5.25 Units Vrms Vrms Vrms Vrms Vrms Vrms Vrms Dynamic Loading The output voltages shall remain within limits specified for the step loading and capacitive loading specified in the table below. The load transient repetition rate shall be tested between 50Hz and 5kHz at duty cycles ranging from 10%-90%. The load transient repetition rate is only a test specification. The step load may occur anywhere within the MIN load to the MAX load conditions. Table 66. Transient Load Requirements Output +3.3V +5V 12V1+12V2+12V3 +5VSB Revision 1.2 Step Load Size (See note 2) 6.0A 4.0A 23A 0.5A Load Slew Rate Test capacitive Load 0.5 A/sec 0.5 A/sec 0.5 A/sec 0.5 A/sec 970 F 400 F 2200 F 1,2 20 F Intel order number G34153-003 113 Appendix A: Integration and Usage Tips Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Notes: 9.4.6 1. Step loads on each 12V output may happen simultaneously. 2. 3. The +12V should be tested with 2200F evenly split between the four +12V rails This will be tested over the range of load conditions in section 9.4.2 Capacitive Loading The power supply shall be stable and meet all requirements with the following capacitive loading ranges. Table 67. Capacitive Loading Conditions 9.4.7 Output +3.3V +5V +12V Min 250 400 500 Max 5000 5000 8000 Units F F F -12V +5VSB 1 20 350 350 F F Grounding The output ground of the pins of the power supply provides the output power return path. The output connector ground pins shall be connected to the safety ground (power supply enclosure). This grounding should be well designed to ensure passing the max allowed Common Mode Noise levels. The power supply shall be provided with a reliable protective earth ground. All secondary circuits shall be connected to protective earth ground. Resistance of the ground returns to chassis shall not exceed 1.0 m. This path may be used to carry DC current. 9.4.8 Closed loop stability The power supply shall be unconditionally stable under all line/load/transient load conditions including capacitive load ranges specified in Section 4.6. A minimum of 45 degrees phase margin and -10dB-gain margin is required. The power supply manufacturer shall provide proof of the unit's closed-loop stability with local sensing through the submission of Bode plots. Closed-loop stability must be ensured at the maximum and minimum loads as applicable. 9.4.9 Residual Voltage Immunity in Standby mode The power supply should be immune to any residual voltage placed on its outputs (Typically a leakage voltage through the system from standby output) up to 500mV. There shall be no additional heat generated, nor stressing of any internal components with this voltage applied to any individual or all outputs simultaneously. It also should not trip the protection circuits during turn on. The residual voltage at the power supply outputs for no load condition shall not exceed 100mV when AC voltage is applied and the PSON# signal is de-asserted. 9.4.10 Common Mode Noise The Common Mode noise on any output shall not exceed 350mV pk-pk over the frequency band of 10Hz to 20MHz. The measurement shall be made across a 100 resistor between each of DC outputs, including ground at the DC power connector and chassis ground (power subsystem enclosure). The test set-up shall use a FET probe such as Tektronix model P6046 or equivalent. 114 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS 9.4.11 Appendix A: Integration and Usage Tips Soft Starting The Power Supply shall contain control circuit which provides monotonic soft start for its outputs without overstress of the AC line or any power supply components at any specified AC line or load conditions. 9.4.12 Zero Load Stability Requirements When the power subsystem operates in a no load condition, it does not need to meet the output regulation specification, but it must operate without any tripping of over-voltage or other fault circuitry. When the power subsystem is subsequently loaded, it must begin to regulate and source current without fault. 9.4.13 Ripple/Noise The maximum allowed ripple/noise output of the power supply is defined in the table below. This is measured over a bandwidth of 10Hz to 20MHz at the power supply output connectors. A 10F tantalum capacitor in parallel with a 0.1F ceramic capacitor is placed at the point of measurement. Table 68. Ripples and Noise +3.3V +5V +12V1,2,3 -12V +5VSB 50mVp-p 50mVp-p 120mVp-p 200mVp-p 50mVp-p The test set-up is shown below. VOUT AC HOT POWER SUPPLY V RETURN AC NEUTRAL LOAD 10uF .1uF LOAD MUST BE ISOLATED FROM THE GROUND OF THE POWER SUPPLY AC GROUND GENERAL NOTES: 1. LOAD THE OUTPUT WITH ITS MINIMUM LOAD CURRENT. 2. CONNECT THE PROBES AS SHOWN. 3. REPEAT THE MEASUREMENTS WITH THE MAXIMUM LOAD ON THE OUTPUT. SCOPE SCOPE NOTE: USE A TEKTRONIX 7834 OSCILLOSCOPE WITH 7A13 AND DIFFERENTIAL PROBE P6055 OR EQUIVALENT. Figure 33. Differential Noise test setup Note: When performing this test, the probe clips and capacitors should be located close to the load. 9.4.14 Timing Requirements These are the timing requirements for the power supply operation. The output voltages must rise from 10% to within regulation limits (Tvout_rise) within 2 to 50ms, except for 5VSB - it is allowed to rise from 1 to 25ms. The +3.3V, +5V and +12V1,+12V2 ,+12V3 output voltages should start to rise approximately at the same time. All outputs must rise monotonically. Each output voltage shall reach regulation within 50ms (T vout_on) of each other during turn on of Revision 1.2 Intel order number G34153-003 115 Appendix A: Integration and Usage Tips Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS the power supply. Each output voltage shall fall out of regulation within 400ms (Tvout_off) of each other during turn off. Table 69 shows the timing requirements for the power supply being turned on and off by the AC input, with PSON held low and the PSON signal, with the AC input applied. All timing requirements must be met for the cross loading condition in section TBD. Table 69. Output Voltage Timing Item Tvout_rise Description Output voltage rise time from each main output. Output rise time for the 5Vstby output. All main outputs must be within regulation of each other within this time. All main outputs must leave regulation within this time. Tvout_on T vout_off Min 2 1 Max 50 25 50 Units ms ms ms 400 ms Vout V1 10% Vout V2 V3 V4 Tvout_off Tvout_rise Tvout_on Figure 34. Output Voltage Timing Table 70. Turn On/Off Timing Item Tsb_on_delay T ac_on_delay Tvout_holdup Tpwok_holdup 116 Description Delay from AC being applied to 5VSB being within regulation. Delay from AC being applied to all output voltages being within regulation. Time all output voltages stay within regulation after loss of AC. Tested at 75% of maximum load. Delay from loss of AC to de-assertion of PWOK. Tested at 75% of maximum load. Intel order number G34153-003 MIN MAX 1500 2500 13 12 UNITS ms ms ms ms Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Item Tpson_on_delay T pson_pwok Tpwok_on T pwok_off Tpwok_low Tsb_vout T5VSB_holdup Description Delay from PSON# active to output voltages within regulation limits. Delay from PSON# deactivate to PWOK being deasserted. Delay from output voltages within regulation limits to PWOK asserted at turn on. Delay from PWOK de-asserted to output voltages (3.3V, 5V, 12V, -12V) dropping out of regulation limits. Duration of PWOK being in the de-asserted state during an off/on cycle using AC or the PSON signal. Delay from 5VSB being in regulation to O/Ps being in regulation at AC turn on. Time the 5VSB output voltage stays within regulation after loss of AC. Appendix A: Integration and Usage Tips MIN MAX 5 400 50 100 500 UNITS ms ms ms ms 1 ms 100 10 1000 ms ms 70 AC Input Tvout_holdup Vout Tpwok_low TAC_on_delay Tsb_on_delay Tpwok_on PWOK 5VSB Tpwok_off Tsb_on_delay Tpwok_on Tpwok_off Tpson_pwok Tpwok_holdup T5VSB_holdup Tsb_vout Tpson_on_delay PSON AC turn on/off cycle PSON turn on/off cycle Figure 35. Turn On/Off Timing (Power Supply Signals) Revision 1.2 Intel order number G34153-003 117 Appendix A: Integration and Usage Tips Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix A: Integration and Usage Tips 118 When adding or removing components or peripherals from the server board, AC power must be removed. With AC power plugged into the server board, 5-V standby is still present even though the server board is powered off. This server board supports The Intel(R) Xeon(R) Processor E5-2600 product family and E5-2600 v2 product family with a Thermal Design Power (TDP) of up to and including 135 Watts (TDP of up to 150W only for Workstation board). Previous generations of Intel(R) Xeon(R) processors are not supported. Processors must be installed in order. CPU 1 must be populated for operating the server board. On the back edge of the server board are eight diagnostic LEDs that display a sequence of amber POST codes during the boot process. If the server board hangs during POST, LEDs display the last POST event run before the hang. This server board only supports registered DDR3 DIMMs (RDIMMs) and unbuffered DDR3 DIMMs (UDIMMs). Mixing of RDIMMs and UDIMMs is not supported. For the best performance, the number of DDR3 DIMMs installed should be balanced across both processor sockets and memory channels. For example, a two-DIMM configuration performs better than a one-DIMM configuration. In a two-DIMM configuration, DIMMs should be installed in DIMM sockets A1 and D1. The Intel(R) Remote Management Module 4 (Intel(R) RMM4) connector is not compatible with any previous versions of the Intel(R) Remote Management Module (Product Order Code - AXXRMM, AXXRMM2, and AXXRMM3). Clear the CMOS with AC power cord plugged. Removing the AC power before performing the CMOS clear operation causes the system to automatically power up and immediately power down after the CMOS clear procedure is followed and AC power is re-applied. If this happens, remove the AC power cord, wait 30 seconds, and then reconnect the AC power cord. Power up the system and proceed to the BIOS Setup utility to reset the desired settings. Normal Integrated BMC functionality is disabled with the BMC Force Update jumper set to the "enabled" position (pins 2-3). The server should never be run with the BMC Force Update jumper set in this position and should only be used when the standard firmware update process fails. This jumper should remain in the default (disabled) position (pins 1- 2) when the server is running normally. When performing a normal BIOS update procedure, the BIOS recovery jumper must be set to its default position (pins 1-2). Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables Appendix B: BMC Sensor Tables This appendix lists the sensor identification numbers and information about the sensor type, name, supported thresholds, assertion and de-assertion information, and a brief description of the sensor purpose. See the Intelligent Platform Management Interface Specification, Version 2.0 for sensor and event/reading-type table information. Sensor Type Codes Sensor table given below lists the sensor identification numbers and information regarding the sensor type, name, supported thresholds, assertion and de-assertion information, and a brief description of the sensor purpose. Refer to the Intelligent Platform Management Interface Specification, Version 2.0 for sensor and event/reading-type table information. Sensor Type The sensor type references the values in the Sensor Type Codes table in the Intelligent Platform Management Interface Specification Second Generation v2.0. It provides a context to interpret the sensor. Event/Reading Type The event/reading type references values from the Event/Reading Type Code Ranges and the Generic Event/Reading Type Code tables in the Intelligent Platform Management Interface Specification Second Generation v2.0. Digital sensors are specific type of discrete sensors that only have two states. Event Thresholds/Triggers The following event thresholds are supported for threshold type sensors: - [u,l][nr,c,nc] upper non-recoverable, upper critical, upper non-critical, lower non-recoverable, lower critical, lower non-critical uc, lc upper critical, lower critical Event triggers are supported event-generating offsets for discrete type sensors. The offsets can be found in the Generic Event/Reading Type Code or Sensor Type Code tables in the Intelligent Platform Management Interface Specification Second Generation v2.0, depending on whether the sensor event/reading type is generic or a sensor-specific response. Assertion/Deassertion Assertion and de-assertion indicators reveal the type of events this sensor generates: - As: Assertion - De: De-assertion Readable Value/Offsets - Readable value indicates the type of value returned for threshold and other nondiscrete type sensors. - Readable offsets indicate the offsets for discrete sensors that are readable by means of the Get Sensor Reading command. Unless otherwise indicated, event triggers are readable. Readable offsets consist of the reading type offsets that do not generate events. Event Data Event data is the data that is included in an event message generated by the associated sensor. For threshold-based sensors, these abbreviations are used: - R: Reading value - T: Threshold value Rearm Sensors Revision 1.2 Intel order number G34153-003 119 Appendix B: BMC Sensor Tables Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS The rearm is a request for the event status for a sensor to be rechecked and updated upon a transition between good and bad states. Rearming the sensors can be done manually or automatically. This column indicates the type supported by the sensor. The following abbreviations are used in the comment column to describe a sensor: - A: Auto-rearm - M: Manual rearm - I: Rearm by init agent Default Hysteresis The hysteresis setting applies to all thresholds of the sensor. This column provides the count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis). Criticality Criticality is a classification of the severity and nature of the condition. It also controls the behavior of the front panel status LED. Standby Some sensors operate on standby power. These sensors may be accessed and/or generate events when the main (system) power is off, but AC power is present. 120 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables Note: All sensors listed below may not be present on all platforms. Please check platform EPS section for platform applicability and platform chassis section for chassis specific sensors. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply). Table 71. Integrated BMC Core Sensors Full Sensor Name (Sensor name in SDR) Sensor Platform # Applicability Sensor Type Event/Reading Type Event Offset Triggers 00 - Power down Power Unit Status (Pwr Unit Status) 01h All Power Unit 09h Sensor Specific 6Fh 02 - 240 VA power down 04 - A/C lost Contrib. To System Status OK Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby As and De - Trig Offset A X As and De - Trig Offset M X Fatal OK 05 - Soft power control failure Fatal 06 - Power unit failure Power Unit Redundancy1 (Pwr Unit Redund) 02h Chassisspecific Power Unit Generic 09h 0Bh 00 - Fully Redundant OK 01 - Redundancy lost Degraded 02 - Redundancy degraded Degraded 03 - Non-redundant: sufficient resources. Transition from full redundant state. Degraded 04 - Non-redundant: sufficient resources. Transition from insufficient state. Degraded 05 - Non-redundant: insufficient resources Fatal 06 - Redundant: degraded from fully redundant state. Revision 1.2 Intel order number G34153-003 Degraded 121 Appendix B: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Sensor Platform # Applicability Sensor Type Event/Reading Type Event Offset Triggers 07 - Redundant: Transition from nonredundant state. Contrib. To System Status Degraded Assert/Deassert Readable Value/ Offsets OK As - Degraded Event Data Rearm Standby 00 - Timer expired, status only IPMI Watchdog (IPMI Watchdog) 03h All Watchdog 2 23h Sensor Specific 6Fh 01 - Hard reset 02 - Power down Trig Offset A X 03 - Power cycle 08 - Timer interrupt Physical Security (Physical Scrty) FP Interrupt (FP NMI Diag Int) SMI Timeout (SMI Timeout) System Event Log (System Event Log) System Event (System Event) 04h 05h 06h 07h 08h Chassis Intrusion is chassisspecific Chassis specific All All All Physical Security Sensor Specific 05h 6Fh Critical Interrupt Sensor Specific 13h 6Fh SMI Timeout F3h Digital Discrete 04 - LAN leash lost OK As and De - Trig Offset A X 00 - Front panel NMI/diagnostic interrupt OK As - Trig Offset A - Fatal As and De - Trig Offset A - OK As - Trig Offset A X As and De - Trig Offset A X 01 - State asserted 03h Event Logging Disabled Sensor Specific 10h 6Fh System Event 12h Sensor Specific 6Fh 02 - Undetermined system H/W failure 04 - PEF action Fatal Sensor Specific 6Fh 00 - Power Button 02 - Reset Button OK AS _ Trig Offset A X Degraded As - Trig Offset A - Button Sensor (Button) 09h All Button/Switch 14h BMC Watchdog 0Ah All Mgmt System Health Digital Discrete 28h 03h 122 00 - Chassis intrusion 02 - Log area reset/cleared 01 - State Asserted Intel order number G34153-003 OK As Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Full Sensor Name (Sensor name in SDR) Voltage Regulator Watchdog (VR Watchdog) Fan Redundancy1 (Fan Redundancy) SSB Thermal Trip (SSB Therm Trip) IO Module Presence Sensor Platform # Applicability 0Bh 0Ch (SAS Mod Presence) Revision 1.2 Chassisspecific Voltage 02h Digital Discrete 04h 0Bh Temperature 01h Digital Discrete 03h Digital Discrete 0Eh Platformspecific Module/Board Platformspecific Module/Board 15h 15h Event Offset Triggers Contrib. To System Status 01 - State Asserted Fatal 03h Generic All 0Fh Event/Reading Type Fan 0Dh (IO Mod Presence) SAS Module Presence All Sensor Type Appendix B: BMC Sensor Tables 00 - Fully redundant OK 01 - Redundancy lost Degraded 02 - Redundancy degraded Degraded 03 - Non-redundant: Sufficient resources. Transition from redundant Degraded 04 - Non-redundant: Sufficient resources. Transition from insufficient. Degraded 05 - Non-redundant: insufficient resources. Non-Fatal 06 - Non-Redundant: degraded from fully redundant. Degraded 07 - Redundant degraded from nonredundant Degraded Readable Value/ Offsets Event Data Rearm Standby As and De - Trig Offset M X As and De - Trig Offset A - 01 - State Asserted Fatal As and De - Trig Offset M X 01 - Inserted/Present OK As and De - Trig Offset M - 01 - Inserted/Present OK As and De - Trig Offset M X 08h Digital Discrete Assert/Deassert 08h Intel order number G34153-003 123 Appendix B: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) BMC Firmware Health Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Sensor Platform # Applicability 10h All (BMC FW Health) System Airflow (System Airflow) FW Update Status 11h All 12h All Sensor Type Mgmt Health 28h Event/Reading Type Sensor Specific Event Offset Triggers 04 - Sensor Failure Contrib. To System Status Degraded Assert/Deassert Readable Value/ Offsets As - Trig Offset A X 6Fh Other Units Threshold 0Bh 01h Version Change 2Bh OEM defined x70h Event Data Rearm Standby - - - Analog - - - 00hUpdate started OK As _ Trig Offset A _ OK As and De - Trig Offset M - As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X 01hUpdate completed successfully. 02hUpdate failure IO Module2 Presence (IO Mod2 Presence) Baseboard Temperature 5 Module/Board 14h Platformspecific Temperature Threshold 01h 01h 15h Platformspecific Temperature Threshold 01h 01h 16h Platformspecific Temperature Threshold 01h 01h 17h Platformspecific Temperature Threshold 01h 01h 13h (Platform Specific) Baseboard Temperature 6 (Platform Specific) IO Module2 Temperature (I/O Mod2 Temp) PCI Riser 3 Temperature (PCI Riser 5 Temp) 124 Digital Discrete Platformspecific 15h 01 - Inserted/Present 08h [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] Intel order number G34153-003 nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Full Sensor Name (Sensor name in SDR) PCI Riser 4 Temperature Sensor Platform # Applicability Platformspecific Temperature Threshold 01h 01h 19h Platformspecific Voltage 02h Threshold 01h 1Ah Platformspecific Voltage 02h Threshold 01h 20h Platformspecific Temperature Threshold 01h 01h Temperature Threshold 01h 01h Temperature Threshold 01h 01h (BB +1.05Vccp P3) Baseboard +1.05V Processor4 Vccp (BB +1.05Vccp P4) Baseboard Temperature 1 (Platform Specific) Front Panel Temperature 21h All (Front Panel Temp) SSB Temperature (SSB Temp) Baseboard Temperature 2 22h All 23h Platformspecific Temperature Threshold 01h 01h 24h Platformspecific Temperature Threshold 01h 01h (Platform Specific) Baseboard Temperature 3 (Platform Specific) Revision 1.2 Event/Reading Type 18h (PCI Riser 4 Temp) Baseboard +1.05V Processor3 Vccp Sensor Type Appendix B: BMC Sensor Tables Event Offset Triggers [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] Intel order number G34153-003 Contrib. To System Status nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby As and De Analog R, T A X As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X 125 Appendix B: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Baseboard Temperature 4 Sensor Platform # Applicability Temperature Threshold 01h 01h 26h Platformspecific Temperature Threshold 01h 01h 27h Platformspecific Temperature Threshold 01h 01h 28h Platformspecific Temperature Threshold 01h 01h 29h Chassisspecific Temperature Threshold 01h 01h 2Ah Chassisspecific Temperature Threshold 01h 01h 2Bh Chassisspecific Temperature Threshold 01h 01h 2Ch Platformspecific Temperature Threshold 01h 01h (PCI Riser 1 Temp) IO Riser Temperature (IO Riser Temp) Hot-swap Backplane 1 Temperature Event/Reading Type Platformspecific (I/O Mod Temp) PCI Riser 1 Temperature Sensor Type 25h (Platform Specific) IO Module Temperature Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Event Offset Triggers [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] (HSBP 1 Temp) Hot-swap Backplane 2 Temperature [u,l] [c,nc] (HSBP 2 Temp) Hot-swap Backplane 3 Temperature [u,l] [c,nc] (HSBP 3 Temp) PCI Riser 2 Temperature (PCI Riser 2 Temp) 126 [u,l] [c,nc] Intel order number G34153-003 Contrib. To System Status nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Full Sensor Name (Sensor name in SDR) SAS Module Temperature Sensor Platform # Applicability 2Dh Platformspecific 2Eh Chassis and Platform Specific (SAS Mod Temp) Exit Air Temperature (Exit Air Temp) Network Interface Controller Temperature 2Fh All 30h- 3Fh Chassis and Platform Specific 40h- 4Fh Chassis and Platform Specific Sensor Type Event/Reading Type Temperature Threshold 01h 01h Temperature Threshold 01h 01h Temperature Threshold 01h 01h Fan Threshold 04h 01h Fan Generic 08h Appendix B: BMC Sensor Tables Event Offset Triggers [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] (LAN NIC Temp) Fan Tachometer Sensors (Chassis specific sensor names) Fan Present Sensors (Fan x Present) Power Supply 1 Status 50h (PS1 Status) Power Supply 2 Status (PS2 Status) Revision 1.2 51h Chassisspecific Chassisspecific 04h Power Supply 08h Power Supply 08h Sensor Specific 6Fh Sensor Specific 6Fh [l] [c,nc] Contrib. To System Status nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal2 01 - Device inserted OK 00 - Presence OK 01 - Failure Degraded 02 - Predictive Failure Degraded 03 - A/C lost Degraded 06 - Configuration error OK 00 - Presence OK 01 - Failure Degraded 02 - Predictive Failure Degraded 03 - A/C lost Degraded 06 - Configuration error OK Intel order number G34153-003 Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T M - As and De - Triggered Offset Auto - As and De - Trig Offset A X As and De - Trig Offset A X 127 Appendix B: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Power Supply 1 AC Power Input Sensor Platform # Applicability Event/Reading Type Chassisspecific Other Units Threshold 0Bh 01h 55h Chassisspecific Other Units Threshold 0Bh 01h 58h Chassisspecific Current Threshold 03h 01h 59h Chassisspecific Current Threshold 03h 01h 5Ch Chassisspecific Temperature Threshold 01h 01h 5Dh Chassisspecific (PS2 Power In) Power Supply 1 +12V % of Maximum Current Output Sensor Type 54h (PS1 Power In) Power Supply 2 AC Power Input Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Event Offset Triggers [u] [c,nc] [u] [c,nc] [u] [c,nc] (PS1 Curr Out %) Power Supply 2 +12V % of Maximum Current Output [u] [c,nc] (PS2 Curr Out %) Power Supply 1 Temperature (PS1 Temperature) Power Supply 2 Temperature (PS2 Temperature) Temperature Threshold 01h [u] [c,nc] [u] [c,nc] 00 - Drive Presence Hard Disk Drive 16 - 24 Status (HDD 16 - 24 Status) 128 60h - 68h Chassisspecific Drive Slot 0Dh Sensor Specific 6Fh 01- Drive Fault Contrib. To System Status nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A X As and De - Trig Offset A X OK Degraded 07 - Rebuild/Remap in progress Degraded Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Full Sensor Name (Sensor name in SDR) Sensor Platform # Applicability Sensor Type Event/Reading Type Appendix B: BMC Sensor Tables Event Offset Triggers Contrib. To System Status Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby - Trig Offset As and De - Trig Offset M X As and De - Trig Offset M X As and De - Trig Offset M X As and De - Trig Offset M X 69h - Chassisspecific Microcontroller 16h Discrete 0Ah Processor Sensor Specific 04- transition to Off Line Degraded X 6Bh Processor 1 Status (P1 Status) Processor 2 Status (P2 Status) Processor 3 Status (P3 Status) Processor 4 Status (P4 Status) 70h 71h 72h 73h All All 07h Processor Platformspecific Processor 74h All Processor 2 Thermal Margin (P2 Therm Margin) 75h All Processor 3 Thermal Margin (P3 Therm Margin) 76h Processor 4 Thermal Margin (P4 Therm Margin) 77h 78h Processor Platformspecific Processor 1 Thermal Margin (P1 Therm Margin) Processor 1 Thermal Control % 07h 07h 07h 6Fh Sensor Specific 6Fh Sensor Specific 6Fh Sensor Specific 6Fh Temperature Threshold 01h 01h Temperature Threshold 01h 01h Platformspecific Temperature Threshold 01h 01h Platformspecific Temperature Threshold 01h 01h Temperature Threshold 01h 01h All 01 - Thermal trip 07 - Presence OK 01 - Thermal trip Fatal 07 - Presence OK 01 - Thermal trip Fatal 07 - Presence OK 01 - Thermal trip Fatal 07 - Presence OK - - - Analog R, T A - - - - Analog R, T A - - - - Analog R, T A - - - - Analog R, T A - As and De Analog Trig Offset A - [u] [c,nc] (P1 Therm Ctrl %) Revision 1.2 Fatal Intel order number G34153-003 nc = Degraded c = Nonfatal 129 Appendix B: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Processor 2 Thermal Control % Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Sensor Platform # Applicability Sensor Type Event/Reading Type Temperature Threshold 01h 01h 79h All 7Ah Platformspecific Temperature Threshold 01h 01h 7Bh Platformspecific Temperature Threshold 01h 01h 7Ch All Processor Digital Discrete Event Offset Triggers [u] [c,nc] (P2 Therm Ctrl %) Processor 3 Thermal Control % [u] [c,nc] (P3 Therm Ctrl %) Processor 4 Thermal Control % [u] [c,nc] (P4 Therm Ctrl %) Processor 1 ERR2 Timeout (P1 ERR2) Processor 2 ERR2 Timeout 7Dh All (P2 ERR2) Processor 3 ERR2 Timeout 7Eh (P3 ERR2) Processor 4 ERR2 Timeout 7Fh (P4 ERR2) Catastrophic Error (CATERR) Processor1 MSID Mismatch (P1 MSID Mismatch) 130 80h 81h 07h Processor 07h Platformspecific Processor Platformspecific Processor All All 07h 07h Processor 07h Processor 07h Contrib. To System Status nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal Analog Trig Offset A - As and De Analog Trig Offset A - As and De Analog Trig Offset A - Trig Offset A - 01 - State Asserted fatal As and De - Trig Offset A - 01 - State Asserted fatal As and De - Trig Offset A - 01 - State Asserted fatal As and De - Trig Offset A - 01 - State Asserted fatal As and De - Trig Offset M - 01 - State Asserted fatal As and De - Trig Offset M - 03h Digital Discrete As and De - 03h Digital Discrete Rearm Standby As and De 03h Digital Discrete Event Data fatal 03h Digital Discrete Readable Value/ Offsets 01 - State Asserted 03h Digital Discrete Assert/Deassert 03h Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Full Sensor Name (Sensor name in SDR) Processor Population Fault Sensor Platform # Applicability 82h All (CPU Missing) Processor 1 DTS Thermal Margin (P1 DTS Therm Mgn) Processor 2 DTS Thermal Margin (P2 DTS Therm Mgn) Processor 3 DTS Thermal Margin (P3 DTS Therm Mgn) Processor 4 DTS Thermal Margin (P4 DTS Therm Mgn) Processor2 MSID Mismatch (P2 MSID Mismatch) Processor 1 VRD Temperature 83h All 84h All 85h All 86h All 87h All 90h All (P1 VRD Hot) Processor 2 VRD Temperature 91h All (P2 VRD Hot) Processor 3 VRD Temperature (P3 VRD Hot) Revision 1.2 92h All Sensor Type Processor 07h Event/Reading Type Digital Discrete Threshold 01h 01h Temperature Threshold 01h 01h Temperature Threshold 01h 01h Temperature Threshold 01h 01h Processor Digital Discrete Temperature 01h Temperature 01h Temperature 01h Event Offset Triggers Contrib. To System Status Assert/Deassert Readable Value/ Offsets Event Data 01 - State Asserted Fatal As and De - Trig Offset M - - - - Analog R, T A - - - - Analog R, T A - - - - Analog R, T A - - - - Analog R, T A - 01 - State Asserted fatal As and De - Trig Offset M - 01 - Limit exceeded Non-fatal As and De - Trig Offset M - 01 - Limit exceeded Non-fatal As and De - Trig Offset M - 01 - Limit exceeded Fatal As and De - Trig Offset M - 03h Temperature 07h Appendix B: BMC Sensor Tables 03h Digital Discrete 05h Digital Discrete 05h Digital Discrete 05h Intel order number G34153-003 Rearm Standby 131 Appendix B: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Processor 4 VRD Temperature Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Sensor Platform # Applicability 93h All (P4 VRD Hot) Processor 1 Memory VRD Hot 0-1 (P1 Mem01 VRD Hot) Processor 1 Memory VRD Hot 2-3 (P1 Mem23 VRD Hot) Processor 2 Memory VRD Hot 0-1 (P2 Mem01 VRD Hot) Processor 2 Memory VRD Hot 2-3 (P2 Mem23 VRD Hot) Processor 3 Memory VRD Hot 0-1 (P3 Mem01 VRD Hot) Processor 3 Memory VRD Hot 2-3 (P4 Mem23 VRD Hot) Processor 4 Memory VRD Hot 0-1 (P4 Mem01 VRD Hot) 132 94h 95h 96h 97h All All All All 98h All 99h All 9Ah All Sensor Type Temperature 01h Temperature 01h Temperature 01h Temperature 01h Temperature 01h Temperature 01h Temperature 01h Temperature 01h Event/Reading Type Assert/Deassert Readable Value/ Offsets Event Data Fatal As and De - Trig Offset M - 01 - Limit exceeded Non-fatal As and De - Trig Offset A - 01 - Limit exceeded Non-fatal As and De - Trig Offset A - 01 - Limit exceeded Non-fatal As and De - Trig Offset A - 01 - Limit exceeded Non-fatal As and De - Trig Offset A - Digital Discrete 05h 01 - Limit exceeded Non-fatal As and De - Trig Offset A - Digital Discrete 05h 01 - Limit exceeded Non-fatal As and De - Trig Offset A - 01 - Limit exceeded Non-fatal As and De - Trig Offset A - Digital Discrete Event Offset Triggers Contrib. To System Status 01 - Limit exceeded 05h Digital Discrete 05h Digital Discrete 05h Digital Discrete 05h Digital Discrete 05h Digital Discrete 05h Intel order number G34153-003 Rearm Standby Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Full Sensor Name (Sensor name in SDR) Processor 4 Memory VRD Hot 2-3 (P4 Mem23 VRD Hot) Power Supply 1 Fan Tachometer 1 (PS1 Fan Tach 1) Power Supply 1 Fan Tachometer 2 (PS1 Fan Tach 2) Power Supply 2 Fan Tachometer 1 (PS2 Fan Tach 1) Power Supply 2 Fan Tachometer 2 (PS2 Fan Tach 2) Processor 1 DIMM Aggregate Thermal Margin 1 (P1 DIMM Thrm Mrgn1) Processor 1 DIMM Aggregate Thermal Margin 2 (P1 DIMM Thrm Mrgn2) Processor 2 DIMM Aggregate Thermal Margin 1 (P2 DIMM Thrm Mrgn1) Processor 2 DIMM Aggregate Thermal Margin 2 (P2 DIMM Thrm Mrgn2) Revision 1.2 Sensor Platform # Applicability 9Bh All Sensor Type Temperature 01h A0h Chassisspecific Fan A1h Chassisspecific Fan A4h Chassisspecific Fan A5h Chassisspecific Fan B0h B1h B2h B3h All All All All 04h 04h 04h 04h Temperature Event/Reading Type Digital Discrete Appendix B: BMC Sensor Tables Event Offset Triggers Contrib. To System Status Assert/Deassert Readable Value/ Offsets Event Data 01 - Limit exceeded Non-fatal As and De - Trig Offset A - 01 - State Asserted Non-fatal As and De - Trig Offset M - 01 - State Asserted Non-fatal As and De - Trig Offset M - 01 - State Asserted Non-fatal As and De - Trig Offset M - 01 - State Asserted Non-fatal As and De - Trig Offset M - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - 05h Generic - digital discrete Generic - digital discrete Generic - digital discrete Generic - digital discrete Threshold 01h 01h Temperature Threshold 01h 01h Temperature Threshold 01h 01h Temperature Threshold 01h 01h [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] Intel order number G34153-003 nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal Rearm Standby 133 Appendix B: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Processor 3 DIMM Aggregate Thermal Margin 1 (P3 DIMM Thrm Mrgn1) Processor 3 DIMM Aggregate Thermal Margin 2 (P3 DIMM Thrm Mrgn2) Processor 4 DIMM Aggregate Thermal Margin 1 (P4 DIMM Thrm Mrgn1) Processor 4 DIMM Aggregate Thermal Margin 2 (P4 DIMM Thrm Mrgn2) Fan Tachometer Sensors (Chassis specific sensor names) Processor 1 DIMM Thermal Trip (P1 Mem Thrm Trip) Processor 2 DIMM Thermal Trip (P2 Mem Thrm Trip) Processor 3 DIMM Thermal Trip (P3 Mem Thrm Trip) 134 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Sensor Platform # Applicability Sensor Type Event/Reading Type B4h Platform Specific Temperature Threshold 01h 01h B5h Platform Specific Temperature Threshold 01h 01h B6h Platform Specific Temperature Threshold 01h 01h B7h Platform Specific Temperature Threshold 01h 01h BAh- BFh Chassis and Platform Specific Fan Threshold 04h 01h Memory C0h All Digital Discrete C1h C2h 0Ch All Memory 0Ch All Memory 0Ch 03h Digital Discrete 03h Digital Discrete 03h Event Offset Triggers [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [l] [c,nc] Contrib. To System Status nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal2 Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T M - 0A- Critical overtemperature Fatal As and De - Trig Offset M - 0A- Critical overtemperature Fatal As and De - Trig Offset M - 0A- Critical overtemperature Fatal As and De - Trig Offset M X Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Full Sensor Name (Sensor name in SDR) Sensor Platform # Applicability Sensor Type Processor 4 DIMM Thermal Trip (P4 Mem Thrm Trip) Global Aggregate Temperature Margin 1 (Agg Therm Mrgn 1) Global Aggregate Temperature Margin 2 (Agg Therm Mrgn 2) Global Aggregate Temperature Margin 3 (Agg Therm Mrgn 3) Global Aggregate Temperature Margin 4 (Agg Therm Mrgn 4) Global Aggregate Temperature Margin 5 (Agg Therm Mrgn 5) Global Aggregate Temperature Margin 6 (Agg Therm Mrgn 6) Global Aggregate Temperature Margin 7 (Agg Therm Mrgn 7) Revision 1.2 C3h All Memory 0Ch Event/Reading Type Digital Discrete 03h C8h Platform Specific Temperature Threshold 01h 01h C9h Platform Specific Temperature Threshold 01h 01h CAh Platform Specific Temperature Threshold 01h 01h CBh Platform Specific Temperature Threshold 01h 01h CCh Platform Specific Temperature Threshold 01h 01h CDh Platform Specific Temperature Threshold 01h 01h CEh Platform Specific Temperature Threshold 01h 01h Appendix B: BMC Sensor Tables Event Offset Triggers Contrib. To System Status Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby 0A- Critical overtemperature Fatal As and De - Trig Offset M X - - - Analog R, T A - - - - Analog R, T A - - - - Analog R, T A - - - - Analog R, T A - - - - Analog R, T A - - - - Analog R, T A - - - - Analog R, T A - Intel order number G34153-003 135 Appendix B: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Global Aggregate Temperature Margin 8 (Agg Therm Mrgn 8) Baseboard +12V (BB +12.0V) Baseboard +5V (BB +5.0V) Baseboard +3.3V (BB +3.3V) Baseboard +5V Stand-by Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Sensor Platform # Applicability CFh D0h D1h D2h D3h Platform Specific All D4h D6h (BB +1.05Vccp P2) 136 D7h Threshold 01h 01h Voltage 02h Threshold 01h Threshold 01h All Voltage 02h Threshold 01h All Voltage 02h Threshold 01h All Voltage 02h Threshold 01h All Voltage 02h Threshold 01h (BB +1.05Vccp P1) Baseboard +1.05V Processor2 Vccp Temperature Voltage 02h (BB +3.3V AUX) Baseboard +1.05V Processor1 Vccp Event/Reading Type All (BB +5.0V STBY) Baseboard +3.3V Auxiliary Sensor Type All Voltage 02h Threshold 01h Event Offset Triggers Contrib. To System Status Assert/Deassert Readable Value/ Offsets Event Data - - - Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A X As and De Analog R, T A X As and De Analog R, T A - As and De Analog R, T A - [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] Intel order number G34153-003 nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal Rearm Standby Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Full Sensor Name (Sensor name in SDR) Baseboard +1.5V P1 Memory AB VDDQ Sensor Platform # Applicability D8h All (BB +1.5 P1MEM AB) Baseboard +1.5V P1 Memory CD VDDQ D9h DAh DBh DCh All Voltage 02h Threshold 01h All Voltage 02h Threshold 01h All Voltage 02h Threshold 01h All Voltage 02h Threshold 01h (BB +1.8V AUX) Baseboard +1.1V Stand-by DDh (BB +1.1V STBY) Baseboard CMOS Battery (BB +3.3V Vbat) Revision 1.2 DEh Threshold 01h Threshold 01h (BB +1.5 P2MEM CD) Baseboard +1.8V Aux Voltage 02h Voltage 02h (BB +1.5 P2MEM AB) Baseboard +1.5V P2 Memory CD VDDQ Event/Reading Type All (BB +1.5 P1MEM CD) Baseboard +1.5V P2 Memory AB VDDQ Sensor Type All Voltage 02h Threshold 01h Appendix B: BMC Sensor Tables Event Offset Triggers [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] Intel order number G34153-003 Contrib. To System Status nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - 137 Appendix B: BMC Sensor Tables Full Sensor Name (Sensor name in SDR) Baseboard +1.35V P1 Low Voltage Memory AB VDDQ Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Sensor Platform # Applicability E4h All (BB +1.35 P1LV AB) Baseboard +1.35V P1 Low Voltage Memory CD VDDQ 138 c = Nonfatal nc = Degraded All Threshold 01h E7h All Voltage 02h Threshold 01h EAh Platform Specific Voltage 02h Threshold 01h EBh Platform Specific Voltage 02h Threshold 01h [u,l] [c,nc] Chassisspecific Drive Slot Sensor Specific 00 - Drive Presence OK 01- Drive Fault Degraded E6h (BB +3.3 RSR2 PGD) Hard Disk Drive 1 15 Status [u,l] [c,nc] nc = Degraded Voltage 02h (BB +3.3 RSR1 PGD) Baseboard +3.3V Riser 2 Power Good Threshold 01h Contrib. To System Status Threshold 01h (BB +1.35 P2LV CD) Baseboard +3.3V Riser 1 Power Good Voltage 02h Event Offset Triggers Voltage 02h (BB +1.35 P2LV AB) Baseboard +1.35V P2 Low Voltage Memory CD VDDQ Event/Reading Type All E5h (BB +1.35 P1LV CD) Baseboard +1.35V P2 Low Voltage Memory AB VDDQ Sensor Type F0h - 0Dh [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] [u,l] [c,nc] Intel order number G34153-003 c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal nc = Degraded c = Nonfatal Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De Analog R, T A - As and De - Trig Offset A X Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Full Sensor Name (Sensor name in SDR) (HDD 1 - 15 Status) Sensor Platform # Applicability FEh Sensor Type Appendix B: BMC Sensor Tables Event/Reading Type Event Offset Triggers 6Fh 07 - Rebuild/Remap in progress Contrib. To System Status Assert/Deassert Readable Value/ Offsets Event Data Rearm Standby Degraded Notes: 1. 2. Revision 1.2 Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply). This is only applicable when the system doesn't support redundant fans. When fan redundancy is supported, then the contribution to system state is driven by the fan redundancy sensor. Intel order number G34153-003 139 Appendix C: Platform Specific BMC Appendix Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix C: Platform Specific BMC Appendix Intel(R) Server Board S2600IP Introduction This is an addendum document to BMC core EPS. This document describes platform and chassis specific information. Product ID Bytes 11:12 (product ID) of Get Device ID command response: 55h 00h IPMI Channel ID Assignments The following table provides information on the BMC channel assignments: Table 72. Intel(R) Server Board S2600IP - BMC Channel Assignments Channel ID 0 Primary IPMB Supports Sessions Yes 1 LAN 1 Yes 2 LAN 2 (platform specific) Yes 3 Interface LAN3 1 Yes (Provided by the Intel(R) Dedicated Server Management NIC) 4 Reserved Yes 5 USB No 6 Secondary IPMB No 7 SMM No 8- 0Dh Reserved - 2 - 0Eh Self 0Fh SMS/Receive Message Queue No Notes: 1. Optional HW supported by the server system. 2. Refers to the actual channel used to send the request. ACPI S3 Sleep State Support Not supported. Processor Support for Intel(R)Server Board S2600IP Intel(R) Xeon(R) processor E5-2600 and E5-2600 v2 product family up to 135 Watt Supported Chassis 140 Intel(R) Server Chassis P4208 (UPL with redundant fan 4U) Intel(R) Server Chassis P4216 (UPL with redundant fan 4U) Intel(R) Server Chassis P4224 (UPL with redundant fan 4U) Intel(R) Server Chassis P4308 (UPL with redundant fan 4U) Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix C: Platform Specific BMC Appendix Intel(R) Server Chassis P4XXX (UPL with redundant fan 4U) Intel(R) Server Chassis R2208 (BHP with redundant fan 2U) Intel(R) Server Chassis R2216 (BHP with redundant fan 2U) Intel(R) Server Chassis R2224 (BHP with redundant fan 2U) Intel(R) Server Chassis R2308 (BHP with redundant fan 2U) Intel(R) Server Chassis R2312 (BHP with redundant fan 2U) Chassis-specific sensors Table 73. Intel(R) Server Board S2600IP - Chassis-specific Sensors Intel(R)Server Chassis P4208/P4216/P4224/ P4308/P4XXX (UPL with redundant fan 4U) R2208/R2216/R2224/P 2308/P2312 (BHP with redundant fan 2U) Fan Tachometer Sensors Fan Presence Sensors Fan 1 Present (40h) Physical Security (Chassis intrusion) sensor Physical Scrty (04h) System Fan 1(30h) System Fan 2(31h) FP Interrupt (FP NMI Diag Int) FP NMI Diag Int (05h) Fan 2 Present (41h) NA NA System Fan 3 (32h) Fan 3 Present (42h) NA NA System Fan 4 (33h) Fan 4 Present (43h) NA NA System Fan 5 (34h) Fan 5 Present (44h) NA NA System Fan 1 (30h) Fan 1 Present (40h) Physical Scrty (04h) FP NMI Diag Int (05h) System Fan 2 (31h) Fan 2 Present (41h) NA NA System Fan 3 (32h) Fan 3 Present (42h) NA NA System Fan 4 (33h) Fan 4 Present (43h) NA NA System Fan 5 (34h) Fan 5 Present (44h) NA NA System Fan 6 (35h) Fan 6 Present (45h) NA NA Hot-plug fan support Supported on: Intel(R) Server Chassis P4208 (UPL with redundant fan 4U) Intel(R) Server Chassis P4216 (UPL with redundant fan 4U) Intel(R) Server Chassis P4224 (UPL with redundant fan 4U) Intel(R) Server Chassis P4308 (UPL with redundant fan 4U) Intel(R) Server Chassis P4XXX (UPL with redundant fan 4U) Intel(R) Server Chassis R2208 (BHP with redundant fan 2U) Intel(R) Server Chassis R2216 (BHP with redundant fan 2U) Intel(R) Server Chassis R2224 (BHP with redundant fan 2U) Intel(R) Server Chassis R2308 (BHP with redundant fan 2U) Intel(R) Server Chassis R2312 (BHP with redundant fan 2U) Fan redundancy support Supported on: Intel(R) Server Chassis P4208 (UPL with redundant fan 4U) Intel(R) Server Chassis P4216 (UPL with redundant fan 4U) Intel(R) Server Chassis P4224 (UPL with redundant fan 4U) Revision 1.2 Intel order number G34153-003 141 Appendix C: Platform Specific BMC Appendix Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Intel(R) Server Chassis P4308 (UPL with redundant fan 4U) Intel(R) Server Chassis P4XXX (UPL with redundant fan 4U) Intel(R) Server Chassis R2208 (BHP with redundant fan 2U) Intel(R) Server Chassis R2216 (BHP with redundant fan 2U) Intel(R) Server Chassis R2224 (BHP with redundant fan 2U) Intel(R) Server Chassis R2308 (BHP with redundant fan 2U) Intel(R) Server Chassis R2312 (BHP with redundant fan 2U) Fan domain definition Table 74. Intel(R) Server Board S2600IP - Fan Domain Definition Chassis 0 Major Components Cooled (Temperature sensor number) SSB Temp(22h) BB BMC Temp(23h) BB MEM VR Temp(25h) I/O Mod Temp(26h) HSBP 1 Temp(29h) HSBP 2 Temp(2Ah) SAS Mod Temp(2Dh) Exit Air Temp(2Eh) LAN NIC Temp(2Fh) 1 SSB Temp(22h) BB BMC Temp(23h) BB MEM VR Temp(25h) I/O Mod Temp(26h) HSBP 1 Temp(29h) HSBP 2 Temp(2Ah) SAS Mod Temp(2Dh) Exit Air Temp(2Eh) LAN NIC Temp(2Fh) System Fan 2(31h) 2 BB P2 VR Temp(24h) BB MEM VR Temp(25h) HSBP 1 Temp(29h) HSBP 2 Temp(2Ah) HSBP 3 Temp(2Bh) SAS Mod Temp(2Dh) Exit Air Temp(2Eh) HDD 20 Status(64h) HDD 21 Status(65h) DIMM Thrm Mrgn 2(B1h) DIMM Thrm Mrgn 3(B2h) System Fan 3(32h) 3 BB P2 VR Temp(24h) HSBP 3 Temp(2Bh) Exit Air Temp(2Eh) P1 Therm Margin(74h) System Fan 4(33h) Fan Domain P4208/P4216/P4224/P4 308/P4XXX (UPL with redundant fan 4U) 142 Intel order number G34153-003 Fans (Sensor number) System Fan 1(30h) Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix C: Platform Specific BMC Appendix Chassis Fan Domain Fans (Sensor number) 4 BB P2 VR Temp(24h) HSBP 3 Temp(2Bh) Exit Air Temp(2Eh) PS1 Temperature(5Ch) PS2 Temperature(5Dh) HDD 20 Status(64h) HDD 21 Status(65h) DIMM Thrm Mrgn 1(B0h) DIMM Thrm Mrgn 4(B3h) System Fan 5(34h) 0 SSB Temp(22h) BB BMC Temp(23h) BB MEM VR Temp(25h) I/O Mod Temp(26h) HSBP 1 Temp(29h) HSBP 2 Temp(2Ah) SAS Mod Temp(2Dh) Exit Air Temp(2Eh) LAN NIC Temp(2Fh) System Fan 1(30h) 1 SSB Temp(22h) BB BMC Temp(23h) BB MEM VR Temp(25h) I/O Mod Temp(26h) HSBP 1 Temp(29h) HSBP 2 Temp(2Ah) SAS Mod Temp(2Dh) Exit Air Temp(2Eh) LAN NIC Temp(2Fh) System Fan 2(31h) 2 SSB Temp(22h) BB P2 VR Temp(24h) HSBP 1 Temp(29h) HSBP 2 Temp(2Ah) P1 Therm Margin(74h) P2 Therm Margin(75h) P2 DTS Therm Mgn(84h) DIMM Thrm Mrgn 2(B1h) DIMM Thrm Mrgn 3(B2h) System Fan 3(32h) 3 BB P2 VR Temp(24h) HSBP 1 Temp(29h) HSBP 2 Temp(2Ah) HSBP 3 Temp(2Bh) Exit Air Temp(2Eh) P1 Therm Margin(74h) P2 Therm Margin(75h) System Fan 4(33h) R2208/R2216/R2224/P2 308/P2312 (BHP with redundant fan 2U) Revision 1.2 Major Components Cooled (Temperature sensor number) P2 Therm Margin(75h) DIMM Thrm Mrgn 1(B0h) DIMM Thrm Mrgn 4(B3h) Intel order number G34153-003 143 Appendix C: Platform Specific BMC Appendix Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Chassis Major Components Cooled (Temperature sensor number) DIMM Thrm Mrgn 1(B0h) DIMM Thrm Mrgn 2(B1h) DIMM Thrm Mrgn 3(B2h) DIMM Thrm Mrgn 4(B3h) 4 SSB Temp(22h) BB P2 VR Temp(24h) HSBP 1 Temp(29h) HSBP 2 Temp(2Ah) P1 Therm Margin(74h) P2 Therm Margin(75h) P2 DTS Therm Mgn(84h) DIMM Thrm Mrgn 2(B1h) DIMM Thrm Mrgn 3(B2h) System Fan 5(34h) 5 BB P2 VR Temp(24h) HSBP 1 Temp(29h) HSBP 2 Temp(2Ah) HSBP 3 Temp(2Bh) Exit Air Temp(2Eh) P1 Therm Margin(74h) P2 Therm Margin(75h) DIMM Thrm Mrgn 1(B0h) DIMM Thrm Mrgn 2(B1h) DIMM Thrm Mrgn 3(B2h) DIMM Thrm Mrgn 4(B3h) System Fan 6(35h) Fan Domain Fans (Sensor number) HSC Availability Intel(R) Server Chassis P4208 (UPL) o Intel Server Chassis P4216 (UPL) o Intel Server Chassis P4224 (UPL) Intel Server Chassis P4308 (UPL) Intel Server Chassis R2208 (BHP) Intel Server Chassis R2216 (BHP) Intel Server Chassis R2224 (BHP) 8-bay 2.5" HDD - FXX8X25HSBP (R) Intel Server Chassis R2308 (BHP) o 144 8-bay 2.5" HDD - FXX8X25HSBP (R) o 8-bay 2.5" HDD - FXX8X25HSBP (R) o 8-bay 3.5" HDD - FUP8X35HSBP (R) o 8-bay 2.5" HDD - FXX8X25HSBP (R) o 8-bay 2.5" HDD - FXX8X25HSBP (R) o 8-bay 2.5" HDD - FXX8X25HSBP (R) 8-bay 3.5" HDD - F2U8X35HSBP Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix C: Platform Specific BMC Appendix Intel(R) Server Chassis R2312 (BHP) o 12-bay 3.5" HDD - F2U12X35HSBP Power unit support Intel(R) Server Chassis P4208/P4216/P4224/P4308 (UPL) Table 75. Intel(R) Server Chassis P4208/P4216/P4224/P4308 (UPL) Power support PS Module Number PMBus* Product Name (in product area of the FRU) PSU Redundant Cold Redundant Fans in each PS 750W HS Power Supply Supported DPS-750XB A Supported Supported 1 PS fan 1200W HS Power Supply Supported DPS-1200TB A Supported Supported 2 PS fan Intel(R) Server Chassis R2208/R2216/R2224/R2308/R2312 (BHP) Table 76. Intel(R) Server Chassis R2208/R2216/R2224/R2308/R2312 (BHP) Power support PS Module Number PMBus* Product Name(in product area of the FRU) PSU Redundant Cold Redundant Fans in each PS 750W HS Power Supply Supported FS750HS1-00 Supported Supported 1 PS fan Redundant Fans only for Intel(R)Server Chassis Intel(R) Server Chassis P4208 (UPL with redundant fan 4U) Intel(R) Server Chassis P4216 (UPL with redundant fan 4U) Intel(R) Server Chassis P4224 (UPL with redundant fan 4U) Intel(R) Server Chassis P4308 (UPL with redundant fan 4U) Intel(R) Server Chassis P4XXX (UPL with redundant fan 4U) Intel(R) Server Chassis R2208 (BHP with redundant fan 2U) Intel(R) Server Chassis R2216 (BHP with redundant fan 2U) Intel(R) Server Chassis R2224 (BHP with redundant fan 2U) Intel(R) Server Chassis R2308 (BHP with redundant fan 2U) Intel(R) Server Chassis R2312 (BHP with redundant fan 2U) Fan Fault LED support Fan fault LEDs are available on the baseboard and on the hot-swap redundant fans available on the following chassis: Intel(R) Server Chassis P4208 (UPL with redundant fan 4U) Intel(R) Server Chassis P4216 (UPL with redundant fan 4U) Intel(R) Server Chassis P4224 (UPL with redundant fan 4U) Intel(R) Server Chassis P4308 (UPL with redundant fan 4U) Revision 1.2 Intel order number G34153-003 145 Appendix C: Platform Specific BMC Appendix Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Intel(R) Server Chassis P4XXX (UPL with redundant fan 4U) Intel(R) Server Chassis R2208 (BHP with redundant fan 2U) Intel(R) Server Chassis R2216 (BHP with redundant fan 2U) Intel(R) Server Chassis R2224 (BHP with redundant fan 2U) Intel(R) Server Chassis R2308 (BHP with redundant fan 2U) Intel(R) Server Chassis R2312 (BHP with redundant fan 2U) Memory Throttling support Baseboard supports this feature. Intel(R) Workstation Board W2600CR Introduction This is an addendum document to BMC core EPS. This document describes platform and chassis specific information. Product ID Bytes 11:12 (product ID) of Get Device ID command response: 56h 00h IPMI Channel ID Assignments The following table provides information on the BMC channel assignments: Table 77. Intel(R) Workstation Board W2600CR - BMC Channel Assignments Channel ID 0 Primary IPMB Supports Sessions Yes 1 LAN 1 Yes 2 LAN 2 (platform specific) Yes 3 Interface LAN3 1 Yes (Provided by the Intel(R) Dedicated Server Management NIC) 4 Reserved Yes 5 USB No 6 Secondary IPMB No 7 SMM No 8- 0Dh Reserved - 2 - 0Eh Self 0Fh SMS/Receive Message Queue No Notes: 1. Optional HW supported by the server system. 2. Refers to the actual channel used to send the request. ACPI S3 Sleep State Support Supported 146 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix C: Platform Specific BMC Appendix Processor Support for Intel(R)Server Board W2600CR Intel(R) Xeon(R) processor E5-2600 product family up to 150 Watt Intel(R) Xeon(R) processor E5-2600 v2 product family up to 150 Watt Supported Chassis Intel(R) Server Chassis P4304 (UPL with fixed fan 4U) Chassis-specific sensors Table 78. Intel(R) Workstation Board W2600CR - Chassis-specific sensors Intel(R)Server Chassis Fan Tachometer Sensors P4304 (UPL with fixed fan 4U) System Fan 1(30h) Fan Presene Sensors NA Physical Security (Chassis intrusion) sensor Physical Scrty(04h) FP NMI Diag Int(05h) System Fan 2(31h) NA NA NA Processor 1 Fan (36h) NA NA NA NA NA NA Processor 2 Fan (37h) detected FP Interrupt (FP NMI Diag Int) Hot-plug fan support Not supported. Fan redundancy support Not supported. Board specific feature Board has not supported serial port A, and SOL will only use serial port B. Fan domain definition Table 79. Intel(R) Workstation Board W2600CR - Fan domain definition Chassis 0 Major Components Cooled (Temperature sensor number) SSB Temp(22h) BB BMC Temp(23h) BB MEM VR Temp(25h) I/O Mod Temp(26h) SAS Mod Temp(2Dh) Exit Air Temp(2Eh) LAN NIC Temp(2Fh) DIMM Thrm Mrgn 2(B1h) DIMM Thrm Mrgn 3(B2h) 1 BB P2 VR Temp(24h) BB MEM VR Temp(25h) Exit Air Temp(2Eh) HDD 20 Status(64h) HDD 21 Status(65h) DIMM Thrm Mrgn 1(B0h) Fan Domain P4304 (UPL with fixed fan 4U) Revision 1.2 Intel order number G34153-003 Fans (Sensor number) System Fan 1(30h) System Fan 2(31h) 147 Appendix C: Platform Specific BMC Appendix Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Chassis Major Components Cooled (Temperature sensor number) DIMM Thrm Mrgn 2(B1h) DIMM Thrm Mrgn 3(B2h) DIMM Thrm Mrgn 4(B3h) Fan Domain Fans (Sensor number) 6 Exit Air Temp(2Eh) P1 Therm Margin(74h) Processor 1 Fan(36h) 7 BB P2 VR Temp(24h) Exit Air Temp(2Eh) P2 Therm Margin(75h) Processor 2 Fan(37h) HSC Availability Not supported. Power unit support Intel(R) Server Chassis P4304 (UPL) Table 80. Intel(R) Server Chassis P4304 (UPL) Power support PS Module Number PMBus* Product Name (in product area of the FRU) PSU Redundant Cold Redundant Fans in each PS 750W HS Power Supply Supported DPS-750XB A Supported Supported 1 PS fan 1200W HS Power Supply Supported DPS-1200TB A Supported Supported 2PS fan Redundant Fans only for Intel(R)Server Chassis Not supported. Fan Fault LED support Not supported. Memory Throttling support 148 Baseboard supports this feature. Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPSAppendix D: POST Code Diagnostic LED Decoder Appendix D: POST Code Diagnostic LED Decoder During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the back edge of the server board. To assist in troubleshooting a system hang during the POST process, the Diagnostic LEDs can be used to identify the last POST process that was executed. Each POST code is represented by a sequence of eight amber diagnostic LEDs. The POST codes are divided into two nibbles, an upper nibble and a lower nibble. The upper nibble bits are represented by diagnostic LEDs #4, #5, #6, and #7. The lower nibble bits are represented by diagnostics LEDs #0, #1, #2, and #3. If the bit is set in the upper and lower nibbles, then the corresponding LED is lit. If the bit is clear, then the corresponding LED is off. The diagnostic LED #7 is labeled as "MSB", and the diagnostic LED #0 is labeled as "LSB". Figure 36. POST Code Diagnostic LED Decoder Revision 1.2 Intel order number G34153-003 149 Appendix D: POST Code Diagnostic LED Decoder Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Note: Diagnostic LEDs are best read and decoded when viewing the LEDs from the back of the system Table 81. POST Progress Code LED Example Upper Nibble AMBER LEDs LEDs Status Results MSB LED #7 8h ON 1 LED #6 4h OFF 0 LED #5 2h ON 1 Lower Nibble GREEN LEDs LED #4 1h OFF 0 LED #3 8h ON 1 Ah LED #2 4h ON 1 LED #1 2h OFF 0 LSB LED #0 1h OFF 0 Ch Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are concatenated as ACh The following table provides a list of all POST progress codes. Table 82. POST Progress Codes Checkpoint Diagnostic LED Decoder 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h #7 #6 #5 #4 #3 #2 #1 #0 LED # Description SEC Phase 01h 0 0 0 0 0 0 0 1 First POST code after CPU reset 02h 0 0 0 0 0 0 1 0 Microcode load begin 03h 0 0 0 0 0 0 1 1 CRAM initialization begin 04h 0 0 0 0 0 1 0 0 Pei Cache When Disabled 05h 0 0 0 0 0 1 0 1 SEC Core At Power On Begin. 06h 0 0 0 0 0 1 1 0 Early CPU initialization during Sec Phase. 07h 0 0 0 0 0 1 1 1 Early SB initialization during Sec Phase. 08h 0 0 0 0 1 0 0 0 Early NB initialization during Sec Phase. 09h 0 0 0 0 1 0 0 1 End Of Sec Phase. 0Eh 0 0 0 0 1 1 1 0 Microcode Not Found. 0Fh 0 0 0 0 1 1 1 1 Microcode Not Loaded. PEI Phase 10h 0 0 0 1 0 0 0 0 PEI Core 11h 0 0 0 1 0 0 0 1 CPU PEIM 15h 0 0 0 1 0 1 0 1 NB PEIM 19h 0 0 0 1 1 0 0 1 SB PEIM MRC Process Codes - MRC Progress Code Sequence is executed - See Table 83. PEI Phase continued... 31h 0 0 1 1 0 0 0 1 Memory Installed 32h 0 0 1 1 0 0 1 0 CPU PEIM (Cpu Init) 33h 0 0 1 1 0 0 1 1 CPU PEIM (Cache Init) 34h 0 0 1 1 0 1 0 0 CPU PEIM (BSP Select) 35h 0 0 1 1 0 1 0 1 CPU PEIM (AP Init) 36h 0 0 1 1 0 1 1 0 CPU PEIM (CPU SMM Init) 4Fh 0 1 0 0 1 1 1 1 Dxe IPL started 60h 0 1 1 0 0 0 0 0 DXE Core started 61h 0 1 1 0 0 0 0 1 DXE NVRAM Init 62h 0 1 1 0 0 0 1 0 SB RUN Init DXE Phase 150 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPSAppendix D: POST Code Diagnostic LED Decoder Checkpoint LED # 63h Diagnostic LED Decoder 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h #7 #6 #5 #4 #3 #2 #1 #0 0 1 1 0 0 0 1 1 Dxe CPU Init 68h 0 1 1 0 1 0 0 0 DXE PCI Host Bridge Init Description 69h 0 1 1 0 1 0 0 1 DXE NB Init 6Ah 0 1 1 0 1 0 1 0 DXE NB SMM Init 70h 0 1 1 1 0 0 0 0 DXE SB Init 71h 0 1 1 1 0 0 0 1 DXE SB SMM Init 72h 0 1 1 1 0 0 1 0 DXE SB devices Init 78h 0 1 1 1 1 0 0 0 DXE ACPI Init 79h 0 1 1 1 1 0 0 1 DXE CSM Init 90h 1 0 0 1 0 0 0 0 DXE BDS Started 91h 1 0 0 1 0 0 0 1 DXE BDS connect drivers 92h 1 0 0 1 0 0 1 0 DXE PCI Bus begin 93h 1 0 0 1 0 0 1 1 DXE PCI Bus HPC Init 94h 1 0 0 1 0 1 0 0 DXE PCI Bus enumeration 95h 1 0 0 1 0 1 0 1 DXE PCI Bus resource requested 96h 1 0 0 1 0 1 1 0 DXE PCI Bus assign resource 97h 1 0 0 1 0 1 1 1 DXE CON_OUT connect 98h 1 0 0 1 1 0 0 0 DXE CON_IN connect 99h 1 0 0 1 1 0 0 1 DXE SIO Init 9Ah 1 0 0 1 1 0 1 0 DXE USB start 9Bh 1 0 0 1 1 0 1 1 DXE USB reset 9Ch 1 0 0 1 1 1 0 0 DXE USB detect 9Dh 1 0 0 1 1 1 0 1 DXE USB enable A1h 1 0 1 0 0 0 0 1 DXE IDE begin A2h 1 0 1 0 0 0 1 0 DXE IDE reset A3h 1 0 1 0 0 0 1 1 DXE IDE detect A4h 1 0 1 0 0 1 0 0 DXE IDE enable A5h 1 0 1 0 0 1 0 1 DXE SCSI begin A6h 1 0 1 0 0 1 1 0 DXE SCSI reset A7h 1 0 1 0 0 1 1 1 DXE SCSI detect A8h 1 0 1 0 1 0 0 0 DXE SCSI enable A9h 1 0 1 0 1 0 0 1 DXE verifying SETUP password ABh 1 0 1 0 1 0 1 1 DXE SETUP start ACh 1 0 1 0 1 1 0 0 DXE SETUP input wait ADh 1 0 1 0 1 1 0 1 DXE Ready to Boot AEh 1 0 1 0 1 1 1 0 DXE Legacy Boot AFh 1 0 1 0 1 1 1 1 DXE Exit Boot Services B0h 1 0 1 1 0 0 0 0 RT Set Virtual Address Map Begin B1h 1 0 1 1 0 0 0 1 RT Set Virtual Address Map End Revision 1.2 Intel order number G34153-003 151 Appendix D: POST Code Diagnostic LED Decoder Checkpoint LED # B2h Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Diagnostic LED Decoder 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h #7 #6 #5 #4 #3 #2 #1 #0 Description 1 0 1 1 0 0 1 0 DXE Legacy Option ROM init B3h 1 0 1 1 0 0 1 1 DXE Reset system B4h 1 0 1 1 0 1 0 0 DXE USB Hot plug B5h 1 0 1 1 0 1 0 1 DXE PCI BUS Hot plug B6h 1 0 1 1 0 1 1 0 DXE NVRAM cleanup B7h 1 0 1 1 0 1 1 1 DXE Configuration Reset 00h 0 0 0 0 0 0 0 0 INT19 E0h 1 1 0 1 0 0 0 0 S3 Resume PEIM (S3 started) E1h 1 1 0 1 0 0 0 1 S3 Resume PEIM (S3 boot script) E2h 1 1 0 1 0 0 1 0 S3 Resume PEIM (S3 Video Repost) E3h 1 1 0 1 0 0 1 1 S3 Resume PEIM (S3 OS wake) S3 Resume BIOS Recovery F0h 1 1 1 1 0 0 0 0 PEIM which detected forced Recovery condition F1h 1 1 1 1 0 0 0 1 PEIM which detected User Recovery condition F2h 1 1 1 1 0 0 1 0 Recovery PEIM (Recovery started) F3h 1 1 1 1 0 0 1 1 Recovery PEIM (Capsule found) F4h 1 1 1 1 0 1 0 0 Recovery PEIM (Capsule loaded) POST Memory Initialization MRC Diagnostic Codes There are two types of POST Diagnostic Codes displayed by the MRC during memory initialization; Progress Codes and Fatal Error Codes. The MRC Progress Codes are displays to the Diagnostic LEDs that show the execution point in the MRC operational path at each step. Table 83. MRC Progress Codes Diagnostic LED Decoder 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED #7 #6 #5 #4 #3 #2 #1 #0 MRC Progress Codes Checkpoint B0h B1h B2h B3h B4h 152 1 1 1 1 1 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 1 0 0 1 1 0 0 1 0 1 0 Description Detect DIMM population Set DDR3 frequency Gather remaining SPD data Program registers on the memory controller level Evaluate RAS modes and save rank information Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPSAppendix D: POST Code Diagnostic LED Decoder Diagnostic LED Decoder 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h #7 #6 #5 #4 #3 #2 #1 #0 1 0 1 1 0 1 0 1 1 0 1 1 0 1 1 0 1 0 1 1 0 1 1 1 1 0 1 1 1 0 0 0 1 0 1 1 1 0 0 1 1 0 1 1 1 0 1 0 1 0 1 1 1 0 1 1 1 0 1 1 1 1 0 0 1 0 1 1 1 1 1 1 Checkpoint LED B5h B6h B7h B8h B9h BAh BBh BCh BFh Description Program registers on the channel level Perform the JEDEC defined initialization sequence Train DDR3 ranks Initialize CLTT/OLTT Hardware memory test and init Execute software memory init Program memory map and interleaving Program RAS configuration MRC is done Memory Initialization at the beginning of POST includes multiple functions, including: discovery, channel training, validation that the DIMM population is acceptable and functional, initialization of the IMC and other hardware settings, and initialization of applicable RAS configurations. When a major memory initialization error occurs and prevents the system from booting with data integrity, a beep code is generated, the MRC will display a fatal error code on the diagnostic LEDs, and a system halt command is executed. Fatal MRC error halts do NOT change the state of the System Status LED, and they do NOT get logged as SEL events. The following table lists all MRC fatal errors that are displayed to the Diagnostic LEDs. Table 84. MRC Fatal Error Codes Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble MSB 8h LED #7 Description LSB 4h #6 2h #5 1h #4 8h #3 4h #2 2h #1 1h #0 MRC Fatal Error Codes E8h E9h 1 1 1 0 1 0 0 0 1 1 1 0 1 0 0 1 1 1 1 0 1 0 1 0 1 1 1 0 1 0 1 1 EAh EBh Revision 1.2 No usable memory error 01h = No memory was detected by SPD read, or invalid config that causes no operable memory. 02h = Memory DIMMs on all channels of all sockets are disabled due to hardware memtest error. 3h = No memory installed. All channels are disabled. Memory is locked by Intel Trusted Execution Technology and is inaccessible DDR3 channel training error 01h = Error on read DQ/DQS (Data/Data Strobe) init 02h = Error on Receive Enable 3h = Error on Write Leveling 04h = Error on write DQ/DQS (Data/Data Strobe Memory test failure 01h = Software memtest failure. Intel order number G34153-003 153 Appendix D: POST Code Diagnostic LED Decoder Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble MSB 8h LED #7 4h #6 2h #5 1h #4 8h #3 4h #2 2h #1 1h #0 EDh EFh 154 Description LSB 1 1 1 0 1 1 0 1 1 1 1 0 1 1 1 1 02h = Hardware memtest failed. 03h = Hardware Memtest failure in Lockstep Channel mode requiring a channel to be disabled. This is a fatal error which requires a reset and calling MRC with a different RAS mode to retry. DIMM configuration population error 01h = Different DIMM types (UDIMM, RDIMM, LRDIMM) are detected installed in the system. 02h = Violation of DIMM population rules. 03h = The 3rd DIMM slot cannot be populated when QR DIMMs are installed. 04h = UDIMMs are not supported in the 3rd DIMM slot. 05h = Unsupported DIMM Voltage. Indicates a CLTT table structure error Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix E: POST Error Messages and Handling Appendix E: POST Error Messages and Handling Most error conditions encountered during POST are reported using POST Error Codes. These codes represent specific failures, warnings, or are informational. POST Error Codes may be displayed in the Error Manager display screen, and are always logged to the System Event Log (SEL). Logged events are available to System Management applications, including Remote and Out of Band (OOB) management. There are exception cases in early initialization where system resources are not adequately initialized for handling POST Error Code reporting. These cases are primarily Fatal Error conditions resulting from initialization of processors and memory, and they are handed by a Diagnostic LED display with a system halt. The following table lists the supported POST Error Codes. Each error code is assigned an error type which determines the action the BIOS will take when the error is encountered. Error types include Minor, Major, and Fatal. The BIOS action for each is defined as follows: Minor: The error message is displayed on the screen or on the Error Manager screen, and an error is logged to the SEL. The system continues booting in a degraded state. The user may want to replace the erroneous unit. The POST Error Pause option setting in the BIOS setup does not have any effect on this error. Major: The error message is displayed on the Error Manager screen, and an error is logged to the SEL. The POST Error Pause option setting in the BIOS setup determines whether the system pauses to the Error Manager for this type of error so the user can take immediate corrective action or the system continues booting. Note that for 0048 "Password check failed", the system halts, and then after the next reset/reboot will displays the error code on the Error Manager screen. Fatal: The system halts during post at a blank screen with the text "Unrecoverable fatal error found. System will not boot until the error is resolved" and "Press to enter setup" The POST Error Pause option setting in the BIOS setup does not have any effect with this class of error. When the operator presses the F2 key on the keyboard, the error message is displayed on the Error Manager screen, and an error is logged to the SEL with the error code. The system cannot boot unless the error is resolved. The user needs to replace the faulty part and restart the system. Note: The POST error codes in the following table are common to all current generation Intel server platforms. Features present on a given server board/system will determine which of the listed error codes are supported. Table 85. POST Error Codes and Messages Error Code 0012 System RTC date/time not set Response Major 0048 Password check failed Major 0140 PCI component encountered a PERR error Major Revision 1.2 Error Message Intel order number G34153-003 155 Appendix E: POST Error Messages and Handling Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Error Code 0141 PCI resource conflict Response Major 0146 PCI out of resources error Major 0191 Processor core/thread count mismatch detected Fatal 0192 0194 Processor cache size mismatch detected Processor family mismatch detected Fatal Fatal 0195 Processor Intel(R) QPI link frequencies unable to synchronize Fatal 0196 Processor model mismatch detected Fatal 0197 Processor frequencies unable to synchronize Fatal 5220 BIOS Settings reset to default settings Major 5221 Passwords cleared by jumper Major 5224 Password clear jumper is Set Major 8130 Processor 01 disabled Major 8131 Processor 02 disabled Major 8132 Processor 03 disabled Major 8133 Processor 04 disabled Major 8160 Processor 01 unable to apply microcode update Major 8161 Processor 02 unable to apply microcode update Major 8162 Processor 03 unable to apply microcode update Major 8163 Processor 04 unable to apply microcode update Major 8170 Processor 01 failed Self Test (BIST) Major 8171 Processor 02 failed Self Test (BIST) Major 8172 Processor 03 failed Self Test (BIST) Major 8173 Processor 04 failed Self Test (BIST) Major 8180 Processor 01 microcode update not found Minor 8181 Processor 02 microcode update not found Minor 8182 Processor 03 microcode update not found Minor 8183 Processor 04 microcode update not found Minor 8190 Watchdog timer failed on last boot Major 8198 OS boot watchdog timer failure Major 8300 Baseboard management controller failed self-test Major 8305 Hot Swap Controller failure Major 83A0 Management Engine (ME) failed Selftest Major 83A1 Management Engine (ME) Failed to respond. Major 84F2 Baseboard management controller failed to respond Major 84F3 Baseboard management controller in update mode Major 84F4 Sensor data record empty Major 84FF System event log full Minor 8500 Memory component could not be configured in the selected RAS mode Major 8501 DIMM Population Error Major 8520 DIMM_A1 failed test/initialization Major 8521 DIMM_A2 failed test/initialization Major 8522 DIMM_A3 failed test/initialization Major 8523 DIMM_B1 failed test/initialization Major 8524 DIMM_B2 failed test/initialization Major 8525 DIMM_B3 failed test/initialization Major 8526 DIMM_C1 failed test/initialization Major 156 Error Message Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix E: POST Error Messages and Handling Error Code 8527 Error Message DIMM_C2 failed test/initialization Response Major 8528 DIMM_C3 failed test/initialization Major 8529 DIMM_D1 failed test/initialization Major 852A DIMM_D2 failed test/initialization Major 852B DIMM_D3 failed test/initialization Major 852C DIMM_E1 failed test/initialization Major 852D DIMM_E2 failed test/initialization Major 852E DIMM_E3 failed test/initialization Major 852F DIMM_F1 failed test/initialization Major 8530 DIMM_F2 failed test/initialization Major 8531 DIMM_F3 failed test/initialization Major 8532 DIMM_G1 failed test/initialization Major 8533 DIMM_G2 failed test/initialization Major 8534 DIMM_G3 failed test/initialization Major 8535 DIMM_H1 failed test/initialization Major 8536 DIMM_H2 failed test/initialization Major 8537 DIMM_H3 failed test/initialization Major 8538 DIMM_I1 failed test/initialization Major 8539 DIMM_I2 failed test/initialization Major 853A DIMM_I3 failed test/initialization Major 853B DIMM_J1 failed test/initialization Major 853C DIMM_J2 failed test/initialization Major 853D DIMM_J3 failed test/initialization Major 853E DIMM_K1 failed test/initialization Major 853F (Go to 85C0) DIMM_K2 failed test/initialization Major 8540 DIMM_A1 disabled Major 8541 DIMM_A2 disabled Major 8542 DIMM_A3 disabled Major 8543 DIMM_B1 disabled Major 8544 DIMM_B2 disabled Major 8545 DIMM_B3 disabled Major 8546 DIMM_C1 disabled Major 8547 DIMM_C2 disabled Major 8548 DIMM_C3 disabled Major 8549 DIMM_D1 disabled Major 854A DIMM_D2 disabled Major 854B DIMM_D3 disabled Major 854C DIMM_E1 disabled Major 854D DIMM_E2 disabled Major 854E DIMM_E3 disabled Major 854F DIMM_F1 disabled Major 8550 DIMM_F2 disabled Major 8551 DIMM_F3 disabled Major 8552 DIMM_G1 disabled Major 8553 DIMM_G2 disabled Major Revision 1.2 Intel order number G34153-003 157 Appendix E: POST Error Messages and Handling Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Error Code 8554 DIMM_G3 disabled Response Major 8555 DIMM_H1 disabled Major 8556 DIMM_H2 disabled Major 8557 DIMM_H3 disabled Major 8558 DIMM_I1 disabled Major 8559 DIMM_I2 disabled Major 855A DIMM_I3 disabled Major 855B DIMM_J1 disabled Major 855C DIMM_J2 disabled Major 855D DIMM_J3 disabled Major 855E DIMM_K1 disabled Major 855F (Go to 85D0) DIMM_K2 disabled Major 8560 DIMM_A1 encountered a Serial Presence Detection (SPD) failure Major 8561 DIMM_A2 encountered a Serial Presence Detection (SPD) failure Major 8562 DIMM_A3 encountered a Serial Presence Detection (SPD) failure Major 8563 DIMM_B1 encountered a Serial Presence Detection (SPD) failure Major 8564 DIMM_B2 encountered a Serial Presence Detection (SPD) failure Major 8565 DIMM_B3 encountered a Serial Presence Detection (SPD) failure Major 8566 DIMM_C1 encountered a Serial Presence Detection (SPD) failure Major 8567 DIMM_C2 encountered a Serial Presence Detection (SPD) failure Major 8568 DIMM_C3 encountered a Serial Presence Detection (SPD) failure Major 8569 DIMM_D1 encountered a Serial Presence Detection (SPD) failure Major 856A DIMM_D2 encountered a Serial Presence Detection (SPD) failure Major 856B DIMM_D3 encountered a Serial Presence Detection (SPD) failure Major 856C DIMM_E1 encountered a Serial Presence Detection (SPD) failure Major 856D DIMM_E2 encountered a Serial Presence Detection (SPD) failure Major 856E DIMM_E3 encountered a Serial Presence Detection (SPD) failure Major 856F DIMM_F1 encountered a Serial Presence Detection (SPD) failure Major 8570 DIMM_F2 encountered a Serial Presence Detection (SPD) failure Major 8571 DIMM_F3 encountered a Serial Presence Detection (SPD) failure Major 8572 DIMM_G1 encountered a Serial Presence Detection (SPD) failure Major 8573 DIMM_G2 encountered a Serial Presence Detection (SPD) failure Major 8574 DIMM_G3 encountered a Serial Presence Detection (SPD) failure Major 8575 DIMM_H1 encountered a Serial Presence Detection (SPD) failure Major 8576 DIMM_H2 encountered a Serial Presence Detection (SPD) failure Major 8577 DIMM_H3 encountered a Serial Presence Detection (SPD) failure Major 8578 DIMM_I1 encountered a Serial Presence Detection (SPD) failure Major 8579 DIMM_I2 encountered a Serial Presence Detection (SPD) failure Major 857A DIMM_I3 encountered a Serial Presence Detection (SPD) failure Major 857B DIMM_J1 encountered a Serial Presence Detection (SPD) failure Major 857C DIMM_J2 encountered a Serial Presence Detection (SPD) failure Major 857D DIMM_J3 encountered a Serial Presence Detection (SPD) failure Major 857E DIMM_K1 encountered a Serial Presence Detection (SPD) failure Major 857F (Go to 85E0) DIMM_K2 encountered a Serial Presence Detection (SPD) failure Major 158 Error Message Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix E: POST Error Messages and Handling Error Code 85C0 Error Message DIMM_K3 failed test/initialization Response Major 85C1 DIMM_L1 failed test/initialization Major 85C2 DIMM_L2 failed test/initialization Major 85C3 DIMM_L3 failed test/initialization Major 85C4 DIMM_M1 failed test/initialization Major 85C5 DIMM_M2 failed test/initialization Major 85C6 DIMM_M3 failed test/initialization Major 85C7 DIMM_N1 failed test/initialization Major 85C8 DIMM_N2 failed test/initialization Major 85C9 DIMM_N3 failed test/initialization Major 85CA DIMM_O1 failed test/initialization Major 85CB DIMM_O2 failed test/initialization Major 85CC DIMM_O3 failed test/initialization Major 85CD DIMM_P1 failed test/initialization Major 85CE DIMM_P2 failed test/initialization Major 85CF DIMM_P3 failed test/initialization Major 85D0 DIMM_K3 disabled Major 85D1 DIMM_L1 disabled Major 85D2 DIMM_L2 disabled Major 85D3 DIMM_L3 disabled Major 85D4 DIMM_M1 disabled Major 85D5 DIMM_M2 disabled Major 85D6 DIMM_M3 disabled Major 85D7 DIMM_N1 disabled Major 85D8 DIMM_N2 disabled Major 85D9 DIMM_N3 disabled Major 85DA DIMM_O1 disabled Major 85DB DIMM_O2 disabled Major 85DC DIMM_O3 disabled Major 85DD DIMM_P1 disabled Major 85DE DIMM_P2 disabled Major 85DF DIMM_P3 disabled Major 85E0 DIMM_K3 encountered a Serial Presence Detection (SPD) failure Major 85E1 DIMM_L1 encountered a Serial Presence Detection (SPD) failure Major 85E2 DIMM_L2 encountered a Serial Presence Detection (SPD) failure Major 85E3 DIMM_L3 encountered a Serial Presence Detection (SPD) failure Major 85E4 DIMM_M1 encountered a Serial Presence Detection (SPD) failure Major 85E5 DIMM_M2 encountered a Serial Presence Detection (SPD) failure Major 85E6 DIMM_M3 encountered a Serial Presence Detection (SPD) failure Major 85E7 DIMM_N1 encountered a Serial Presence Detection (SPD) failure Major 85E8 DIMM_N2 encountered a Serial Presence Detection (SPD) failure Major 85E9 DIMM_N3 encountered a Serial Presence Detection (SPD) failure Major 85EA DIMM_O1 encountered a Serial Presence Detection (SPD) failure Major 85EB DIMM_O2 encountered a Serial Presence Detection (SPD) failure Major 85EC DIMM_O3 encountered a Serial Presence Detection (SPD) failure Major Revision 1.2 Intel order number G34153-003 159 Appendix E: POST Error Messages and Handling Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Error Code 85ED Error Message DIMM_P1 encountered a Serial Presence Detection (SPD) failure Response Major 85EE DIMM_P2 encountered a Serial Presence Detection (SPD) failure Major 85EF DIMM_P3 encountered a Serial Presence Detection (SPD) failure Major 8604 POST Reclaim of non-critical NVRAM variables Minor 8605 BIOS Settings are corrupted Major 8606 NVRAM variable space was corrupted and has been reinitialized Major 92A3 Serial port component was not detected Major 92A9 Serial port component encountered a resource conflict error Major A000 TPM device not detected. Minor A001 TPM device missing or not responding. Minor A002 TPM device failure. Minor A003 TPM device failed self test. Minor A100 BIOS ACM Error Major A421 PCI component encountered a SERR error Fatal A5A0 PCI Express* component encountered a PERR error Minor A5A1 PCI Express* component encountered an SERR error Fatal A6A0 DXE Boot Services driver: Not enough memory available to shadow a Legacy Option ROM. Minor POST Error Beep Codes The following table lists the POST error beep codes. Prior to system video initialization, the BIOS uses these beep codes to inform users on error conditions. The beep code is followed by a user-visible code on the POST Progress LEDs Table 86. POST Error Beep Codes Beeps Error Message USB device action POST Progress Code NA 1 long Intel(R) TXT security violation 0xAE, 0xAF 3 Memory error See Tables 28 and 29 2 BIOS Recovery started BIOS Recovery failure NA 1 4 NA Description Short beep sounded whenever a USB device is discovered in POST, or inserted or removed during runtime System halted because Intel(R) Trusted Execution Technology detected a potential violation of system security. System halted because a fatal error related to the memory was detected. Recovery boot has been initiated BIOS recovery has failed. This typically happens so quickly after recovery us initiated that it sounds like a 2-4 beep code. The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each time the problem is discovered, such as on each power-up attempt, but are not sounded continuously. Codes that are common across all Intel server boards and systems that use same generation chipset are listed in the following table. Each digit in the code is represented by a sequence of beeps whose count is equal to the digit. 160 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Appendix E: POST Error Messages and Handling Table 87. Integrated BMC Beep Codes Code 1-5-2-1 Reason for Beep No CPUs installed or first CPU socket is empty. Associated Sensors CPU1 socket is empty, or sockets are populated incorrectly CPU1 must be populated before CPU2. 1-5-2-4 MSID Mismatch 1-5-4-2 Power fault 1-5-4-4 1-5-1-2 Power control fault (power good assertion timeout). VR Watchdog Timer sensor assertion 1-5-1-4 Power Supply Status MSID mismatch occurs if a processor is installed into a system board that has incompatible power capabilities. DC power unexpectedly lost (power good dropout) - Power unit sensors report power unit failure offset Power good assertion timeout - Power unit sensors report soft power control failure offset VR controller DC power on sequence was not completed in time. The system does not power on or unexpectedly powers off and a Power Supply Unit (PSU) is present that is an incompatible model with one or more other PSUs in the system. Revision 1.2 Intel order number G34153-003 161 Glossary Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Glossary This appendix contains important terms used in the preceding chapters. For ease of use, numeric entries are listed first (for example, 82460GX) with alpha entries following (for example, AGP 4x). Acronyms are then entered in their respective place, with non-acronyms following. Term ACPI Advanced Configuration and Power Interface AP Application Processor APIC Advanced Programmable Interrupt Control ASIC Application Specific Integrated Circuit BIOS Basic Input/Output System BIST Built-In Self Test BMC Baseboard Management Controller Bridge Circuitry connecting one computer bus to another, allowing an agent on one to access the other BSP Bootstrap Processor byte 8-bit quantity. CBC Chassis Bridge Controller (A microcontroller connected to one or more other CBCs, together they bridge the IPMB buses of multiple chassis. CEK Common Enabling Kit CHAP Challenge Handshake Authentication Protocol CMOS In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes of memory, which normally resides on the server board. DPC Direct Platform Control EEPROM Electrically Erasable Programmable Read-Only Memory EHCI Enhanced Host Controller Interface EMP Emergency Management Port EPS External Product Specification FMB Flexible Mother Board FMC Flex Management Connector FMM Flex Management Module FRB Fault Resilient Booting FRU Field Replaceable Unit FSB Front Side Bus GB 1024MB GPIO General Purpose I/O GTL Gunning Transceiver Logic HSC Hot-Swap Controller Hz Hertz (1 cycle/second) I2C Inter-Integrated Circuit Bus IA Intel(R) Architecture IBF Input Buffer ICH I/O Controller Hub ICMB Intelligent Chassis Management Bus IERR Internal Error IFB I/O and Firmware Bridge 162 Definition Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Term INTR Interrupt IP Internet Protocol IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface IR Infrared ITP In-Target Probe KB 1024 bytes KCS Keyboard Controller Style LAN Local Area Network LCD Liquid Crystal Display LED Light Emitting Diode LPC Low Pin Count LUN Logical Unit Number MAC Media Access Control MB 1024KB mBMC National Semiconductor(c) PC87431x mini BMC MCH Memory Controller Hub MD2 Message Digest 2 - Hashing Algorithm MD5 Message Digest 5 - Hashing Algorithm - Higher Security ms milliseconds MTTR Memory Tpe Range Register Mux Multiplexor NIC Network Interface Controller NMI Nonmaskable Interrupt OBF Output Buffer OEM Original Equipment Manufacturer Ohm Unit of electrical resistance PEF Platform Event Filtering PEP Platform Event Paging PIA Platform Information Area (This feature configures the firmware for the platform hardware) PLD Programmable Logic Device PMI Platform Management Interrupt POST Power-On Self Test PSMI Power Supply Management Interface PWM Pulse-Width Modulation RAM Random Access Memory RASUM Reliability, Availability, Serviceability, Usability, and Manageability RISC Reduced Instruction Set Computing ROM Read Only Memory RTC Real-Time Clock (Component of ICH peripheral chip on the server board) SDR Sensor Data Record SECC Single Edge Connector Cartridge SEEPROM Serial Electrically Erasable Programmable Read-Only Memory SEL System Event Log SIO Server Input/Output Revision 1.2 Glossary Definition Intel order number G34153-003 163 Glossary Term Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS SMI Definition Server Management Interrupt (SMI is the highest priority nonmaskable interrupt) SMM Server Management Mode SMS Server Management Software SNMP Simple Network Management Protocol TBD To Be Determined TIM Thermal Interface Material UART Universal Asynchronous Receiver/Transmitter UDP User Datagram Protocol UHCI Universal Host Controller Interface UTC Universal time coordinare VID Voltage Identification VRD Voltage Regulator Down Word 16-bit quantity ZIF Zero Insertion Force 164 Intel order number G34153-003 Revision 1.2 Intel(R)Server Board S2600IP and Intel(R)Workstation Board W2600CR TPS Reference Documents Reference Documents See the following document for additional information: BIOS for EPSD Platforms Based on Intel(R) Xeon Processor E5-4600/2600/2400/1600 Product Families External Product Specification EPSD Platforms Based On Intel Xeon(R) Processor E5 4600/2600/2400/1600 Product Families BMC Core Firmware External Product Specification Intel(R) Server System P4000IP/CR Technical Product Specification Intel(R) Server System R2000IP Technical Product Specification Intel(R) Remote Management Module 4 Technical Product Specification Intelligent Platform Management Interface Specification SmaRT and CLST Architecture on "Romley" Systems and Power Supplies Specification (Doc Reference # 461024) Intel Integrated RAID Module RMS25PB080, RMS25PB040, RMS25CB080, and RMS25CB040 Hardware User's Guide Revision 1.2 Intel order number G34153-003 165 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Intel: W2600CR2 S2600IP4