Intel®
Server Board S2600IP and
Intel® Workstation Board W2600CR
Technical Product Specification
Intel order number G34153-003
Revision 1.2
October, 2013
Enterprise Platforms and Services Division - Marketing
Revision History Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
ii
Revision History
Date
Revision
Number
Modifications
February, 2012
1.0
June, 2012
1.1
October, 2013
1.2
Disclaimers
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,
EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS
GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR
SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR
IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR
INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly,
in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION
CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES,
SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH,
HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS'
FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL
INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR
NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF
THE INTEL PRODUCT OR ANY OF ITS PARTS.
Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not
rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined". Intel reserves
these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from
future changes to them. The information here is subject to change without notice. Do not finalize a design with this
information.
The products described in this document may contain design defects or errors known as errata which may cause the
product to deviate from published specifications. Current characterized errata are available on request.
Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your
product order.
Copies of documents which have an order number and are referenced in this document, or other Intel literature, may
be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/literature.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Table of Contents
Revision 1.2 Intel order number G34153-003
iii
Table of Contents
1. Introduction .......................................................................................................................... 1
1.1 Chapter Outline ........................................................................................................ 1
1.2 Server Board Use Disclaimer .................................................................................. 1
2. Product Overview ................................................................................................................. 2
2.1 Product Feature Set ................................................................................................. 3
2.1.1 Main Board Connector and Component Layout ...................................................... 5
2.1.2 Main Board Rear I/O Layout .................................................................................... 8
2.1.3 Server Board Mechanical Drawings ...................................................................... 10
3. Functional Architecture ..................................................................................................... 19
3.1 Processor Support ................................................................................................. 20
3.1.1 Processor Socket Assembly .................................................................................. 20
3.1.2 Processor Population Rules .................................................................................. 21
3.1.3 Processor Initialization Error Summary ................................................................. 22
3.2 Processor Functions Overview .............................................................................. 25
3.2.1 Intel® QuickPath Interconnect ................................................................................ 26
3.2.2 Integrated Memory Controller (IMC) and Memory Subsystem .............................. 26
3.2.3 Processor Integrated I/O Module (IIO) ................................................................... 32
3.3 Intel® C600-A Chipset Functional overview ........................................................... 34
3.3.1 Digital Media Interface (DMI) ................................................................................. 34
3.3.2 PCI Express* Interface .......................................................................................... 34
3.3.3 Serial ATA (SATA) Controller ................................................................................ 34
3.3.4 Serial Attached SCSI (SAS)/SATA (SCU) Controller ............................................. 35
3.3.5 AHCI ...................................................................................................................... 35
3.3.6 Rapid Storage Technology .................................................................................... 35
3.3.7 PCI Interface .......................................................................................................... 36
3.3.8 Low Pin Count (LPC) Interface .............................................................................. 36
3.3.9 Serial Peripheral Interface (SPI) ............................................................................ 36
3.3.10 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller) ..... 36
3.3.11 Advanced Programmable Interrupt Controller (APIC) ........................................... 36
3.3.12 Universal Serial Bus (USB) Controllers ................................................................. 36
3.3.13 Gigabit Ethernet Controller .................................................................................... 36
3.3.14 RTC ....................................................................................................................... 37
3.3.15 GPIO ...................................................................................................................... 37
3.3.16 Enhanced Power Management ............................................................................. 37
3.3.17 Manageability ......................................................................................................... 37
3.3.18 System Management Bus (SMBus* 2.0) ............................................................... 37
3.3.19 Integrated NVSRAM controller .............................................................................. 37
3.3.20 Virtualization Technology for Directed I/O (Intel® VT-d) ........................................ 38
3.3.21 JTAG Boundary-Scan ............................................................................................ 38
Table of Contents Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
iv
3.3.22 KVM/Serial Over Lan (SOL) Function .................................................................... 38
3.3.23 On-board SAS/SATA Support and Options ........................................................... 38
3.4 PCI Subsystem ...................................................................................................... 39
3.5 Network Interface Controller .................................................................................. 40
3.5.1 Network Interface ................................................................................................... 40
3.6 I/O Module Support (not avaiable for Intel® Server Board S2600IP4L and Intel®
Workstation Board W2600CR2L) ............................................................................................ 41
3.7 SAS ROC Module Support .................................................................................... 42
3.8 HD Audio Support (Intel® Workstation Board W2600CR Only) ............................. 43
3.9 USB3.0 Support (Intel® Workstation Board W2600CR Only) ................................ 44
3.10 IEEE1394b Support (Intel® Workstation Board W2600CR Only) ........................... 45
4. Platform Management Overview ....................................................................................... 46
4.1 Server Management Function Architecture ........................................................... 46
4.1.1 Feature Support ..................................................................................................... 46
4.1.2 Basic and Advanced Features ............................................................................... 48
4.1.3 Integrated BMC Hardware: Emulex* Pilot III .......................................................... 49
4.2 Server Management Functional Specifications ..................................................... 51
4.2.1 BMC Internal Timestamp Clock ............................................................................. 51
4.2.2 System Event Log (SEL) ....................................................................................... 52
4.2.3 Sensor Data Record (SDR) Repository ................................................................. 52
4.2.4 Field Replaceable Unit (FRU) Inventory Device .................................................... 52
4.2.5 BMC Beep Codes .................................................................................................. 52
4.2.6 Diagnostic Interrupt (NMI) Button .......................................................................... 53
4.2.7 BMC Watchdog ...................................................................................................... 53
4.3 Sensor Monitoring .................................................................................................. 54
4.3.1 Overview ................................................................................................................ 54
4.3.2 Core Sensor List for EPSD Platforms Based on Intel® Xeon® Processor E5
4600/2600/2400/1600/1400 Product Families ...................................................................... 54
4.3.3 BMC System Management Health Monitoring ....................................................... 55
4.3.4 Processor Sensors ................................................................................................ 56
4.4 Thermal and Acoustic Management ...................................................................... 59
4.4.1 Set Throttling Mode ............................................................................................... 60
4.4.2 Altitude ................................................................................................................... 60
4.4.3 Set Fan Profile ....................................................................................................... 60
4.4.4 Fan PWM Offset .................................................................................................... 60
4.4.5 Quiet Fan Idle Mode .............................................................................................. 60
4.4.6 Thermal Sensor Input for Fan Speed Control ........................................................ 61
4.4.7 Power Supply Status\Health Sensors .................................................................... 62
4.4.8 System Event Sensor ............................................................................................ 63
4.5 Platform Management Interface ............................................................................ 64
4.5.1 Channel Management ........................................................................................... 65
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Table of Contents
Revision 1.2 Intel order number G34153-003
v
4.5.2 User Model ............................................................................................................ 65
4.5.3 LAN Interface ......................................................................................................... 65
4.6 BMC Firmware Update .......................................................................................... 75
4.6.1 The BMC firmware release Number ...................................................................... 75
4.6.2 Boot Recovery Mode ............................................................................................. 75
4.6.3 Force Firmware Update Jumper ............................................................................ 76
4.6.4 Fast Firmware Update over USB ........................................................................... 76
4.7 Advanced Management Feature Support .............................................................. 77
4.7.1 Enabling Advanced Management Features ........................................................... 77
4.7.2 Keyboard, Video, Mouse (KVM) Redirection ......................................................... 77
4.7.3 Media Redirection .................................................................................................. 78
4.8 Intel® Intelligent Power Node Manager (NM) ......................................................... 80
4.8.1 Overview ................................................................................................................ 80
4.9 EU Lot 6 Mode ....................................................................................................... 81
5. System Security ................................................................................................................. 82
5.1 BIOS Password Protection .................................................................................... 82
5.2 Trusted Platform Module (TPM) Support ............................................................... 84
5.2.1 TPM security BIOS ................................................................................................ 84
5.2.2 Physical Presence ................................................................................................. 85
5.2.3 TPM Security Setup Options ................................................................................. 85
5.3 Intel® Trusted Execution Technology ..................................................................... 87
6. Connector/Header Locations and Pin-outs ..................................................................... 88
6.1 Power Connectors ................................................................................................. 88
6.1.1 Main Power Connector .......................................................................................... 88
6.1.2 CPU Power Connectors ......................................................................................... 88
6.1.3 Add-in Card Power Connectors ............................................................................. 88
6.2 Front Panel Header and Connectors ..................................................................... 89
6.2.1 Front Panel Header ............................................................................................... 89
6.2.2 Front Panel USB Connector .................................................................................. 90
6.2.3 Local Control Panel Connector .............................................................................. 90
6.3 On Board Storage Connectors .............................................................................. 90
6.3.1 SATA Connectors: 6Gbps ..................................................................................... 90
6.3.2 Multiport Mini-SAS/SATA Connectors ................................................................... 91
6.3.3 Intel® RAID C600 Upgrade Key Connector ............................................................ 92
6.3.4 HSBP_I2C Header ................................................................................................. 92
6.3.5 HDD LED Header .................................................................................................. 92
6.3.6 Internal Type- A USB Connector ........................................................................... 92
6.3.7 Internal eUSB SSD Header ................................................................................... 93
6.4 Management and Security Connectors ................................................................. 93
6.4.1 RMM4_Lite Connector ........................................................................................... 93
6.4.2 RMM4_NIC Connector .......................................................................................... 93
Table of Contents Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
vi
6.4.3 TPM Connector ...................................................................................................... 94
6.4.4 PMBus* Connector ................................................................................................ 94
6.4.5 Chassis Intrusion Header ...................................................................................... 94
6.4.6 IPMB Connector .................................................................................................... 94
6.5 FAN Connectors .................................................................................................... 94
6.5.1 System FAN Connectors ....................................................................................... 95
6.5.2 CPU FAN Connector ............................................................................................. 95
6.6 Serial Port and Video Connectors ......................................................................... 95
6.6.1 Serial Port A Connector (DB9, for Intel® Server Board S2600IP only) .................. 95
6.6.2 Serial Port B Connector ......................................................................................... 96
6.6.3 Video Connector (For Intel® Server Board S2600IP only) ..................................... 96
6.6.4 Internal Video header (For Intel® Workstation Board W2600CR only) .................. 97
7. Jumper Blocks .................................................................................................................... 98
7.1 BIOS Default and Password Reset Usage Procedure ........................................... 99
7.1.1 Set BIOS to default (Clearing the CMOS) ............................................................. 99
7.1.2 Clearing the Password ........................................................................................... 99
7.2 Force BMC Update Procedure ............................................................................ 100
7.3 BIOS Recovery Jumper ....................................................................................... 100
7.4 ME Force Update Jumper .................................................................................... 101
8. Intel® Light Guided Diagnostics ...................................................................................... 102
8.1 5-volt Stand-by LED ............................................................................................. 102
8.2 Fan Fault LED ...................................................................................................... 102
8.3 CPU Fault LED .................................................................................................... 102
8.4 DIMM Fault LEDs ................................................................................................ 104
8.5 System ID LED, System Status LED and POST Code Diagnostic LEDs ............ 104
8.5.1 System ID LED .................................................................................................... 105
8.5.2 System Status LED .............................................................................................. 106
8.5.3 POST Code Diagnostic LEDs .............................................................................. 107
9. Design and Environmental Specifications ..................................................................... 108
9.1 Products Design Specifications ........................................................................... 108
9.2 MTBF ................................................................................................................... 108
9.3 Server Board Power Requirements ..................................................................... 111
9.3.1 Processor Power Support .................................................................................... 112
9.4 Power Supply Output Requirements ................................................................... 112
9.4.1 Output Power/Currents ........................................................................................ 112
9.4.2 Cross Loading ...................................................................................................... 112
9.4.3 Standby Output .................................................................................................... 113
9.4.4 Voltage Regulation .............................................................................................. 113
9.4.5 Dynamic Loading ................................................................................................. 113
9.4.6 Capacitive Loading .............................................................................................. 114
9.4.7 Grounding ............................................................................................................ 114
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Table of Contents
Revision 1.2 Intel order number G34153-003
vii
9.4.8 Closed loop stability ............................................................................................. 114
9.4.9 Residual Voltage Immunity in Standby mode ...................................................... 114
9.4.10 Common Mode Noise .......................................................................................... 114
9.4.11 Soft Starting ......................................................................................................... 115
9.4.12 Zero Load Stability Requirements ....................................................................... 115
9.4.13 Ripple/Noise ........................................................................................................ 115
9.4.14 Timing Requirements ........................................................................................... 115
Appendix A: Integration and Usage Tips .............................................................................. 118
Appendix B: BMC Sensor Tables .......................................................................................... 119
Appendix C: Platform Specific BMC Appendix .................................................................... 140
Introduction ......................................................................................................................... 140
Product ID .......................................................................................................................... 140
IPMI Channel ID Assignments ........................................................................................... 140
ACPI S3 Sleep State Support ............................................................................................ 140
Processor Support for Intel® Server Board S2600IP .......................................................... 140
Supported Chassis ............................................................................................................. 140
Chassis-specific sensors .................................................................................................... 141
Hot-plug fan support ........................................................................................................... 141
Fan redundancy support .................................................................................................... 141
Fan domain definition ......................................................................................................... 142
HSC Availability .................................................................................................................. 144
Power unit support ............................................................................................................. 145
Redundant Fans only for Intel® Server Chassis ................................................................. 145
Fan Fault LED support ....................................................................................................... 145
Memory Throttling support ................................................................................................. 146
Introduction ......................................................................................................................... 146
Product ID .......................................................................................................................... 146
IPMI Channel ID Assignments ........................................................................................... 146
ACPI S3 Sleep State Support ............................................................................................ 146
Processor Support for Intel® Server Board W2600CR ....................................................... 147
Supported Chassis ............................................................................................................. 147
Chassis-specific sensors .................................................................................................... 147
Hot-plug fan support ........................................................................................................... 147
Fan redundancy support .................................................................................................... 147
Board specific feature ......................................................................................................... 147
Fan domain definition ......................................................................................................... 147
HSC Availability .................................................................................................................. 148
Table of Contents Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
viii
Power unit support ............................................................................................................. 148
Redundant Fans only for Intel® Server Chassis ................................................................. 148
Fan Fault LED support ....................................................................................................... 148
Memory Throttling support ................................................................................................. 148
Appendix D: POST Code Diagnostic LED Decoder ............................................................. 149
Appendix E: POST Error Messages and Handling .............................................................. 155
Glossary ................................................................................................................................... 162
Reference Documents ............................................................................................................ 165
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS List of Figures
Revision 1.2 Intel order number G34153-003
ix
List of Figures
Figure 1. Intel® Server Board S2600IP ......................................................................................... 2
Figure 2. Intel® Workstation Board W2600CR .............................................................................. 2
Figure 3. Intel® Server Board S2600IP Major Components .......................................................... 6
Figure 4. Intel® Server Board S2600IP Rear I/O Layout ............................................................... 8
Figure 5. Intel® Workstation Board W2600CR Rear I/O Layout .................................................... 9
Figure 6. Mounting Hole Locations (1 of 2) ................................................................................. 10
Figure 7. Mounting Hole Locations (2 of 2) ................................................................................. 11
Figure 8. Major Connector Pin-1 Locations (1 of 3) .................................................................... 12
Figure 9. Major Connector Pin-1 Locations (2 of 3) .................................................................... 13
Figure 10. Major Connector Pin-1 Locations (3 of 3) .................................................................. 14
Figure 11. Primary Side Keep-out Zone ..................................................................................... 16
Figure 12. Primary Side Card-Side Keep-out Zone .................................................................... 17
Figure 13. Second Side Keep-out Zone ...................................................................................... 18
Figure 14. Intel® Server Board S2600IP Functional Block Diagram ........................................... 19
Figure 15. Intel® Workstation Board W2600CR Functional Block Diagram ................................ 20
Figure 16. Processor Socket Assembly ...................................................................................... 21
Figure 17. Processor Socket ILM ................................................................................................ 21
Figure 18. Integrated Memory Controller Functional Block Diagram .......................................... 26
Figure 19. DIMM Slot Layout ...................................................................................................... 30
Figure 20. External RJ45 NIC Port LED Definition ..................................................................... 41
Figure 21. Supported I/O Module Options .................................................................................. 42
Figure 22. USB3.0 Discrete Host Controller Block Diagram ....................................................... 44
Figure 23. IEEE 1394b Discrete Host Controller Block Diagram ................................................ 45
Figure 24. Integrated BMC Hardware ......................................................................................... 51
Figure 25. High-level Fan Speed Control Process ...................................................................... 61
Figure 26. Setup Utility TPM Configuration Screen ................................................................. 86
Figure 27. Video Connector Pin-out ............................................................................................ 96
Figure 28. Jumper Blocks (J1C3, J1F1, J1F2, J2F3, J2F2) ....................................................... 98
Figure 29. Stand by LED, Fan Fault LED and CPU Fault LED Location .................................. 103
Figure 30. DIMM Fault LED’s Location ..................................................................................... 104
Figure 31. Location of System Status, System ID and POST Code Diagnostic LEDs .............. 105
Figure 32. Power Distribution Block Diagram ........................................................................... 111
Figure 33. Differential Noise test setup ..................................................................................... 115
Figure 34. Output Voltage Timing ............................................................................................. 116
Figure 35. Turn On/Off Timing (Power Supply Signals) ............................................................ 117
Figure 36. POST Code Diagnostic LED Decoder ..................................................................... 149
List of Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
x
List of Tables
Table 1. Product Feature Set ........................................................................................................ 3
Table 2. Mixed Processor Configurations Error Summary. ......................................................... 23
Table 3. UDIMM Support Guidelines .......................................................................................... 27
Table 4. RDIMM Support Guidelines .......................................................................................... 28
Table 5. LRDIMM Support Guidelines ........................................................................................ 29
Table 6. DIMM Nomenclature ..................................................................................................... 30
Table 7. Intel® RAID C600 Upgrade Key Options ....................................................................... 35
Table 8. Intel® Server Board S2600IP/Workstation Board W2600CR PCI Bus Segment
Characteristics ...................................................................................................................... 39
Table 9. Supported Intel® Integrated RAID Modules ................................................................... 43
Table 10. Standard Speaker Channels ....................................................................................... 44
Table 11. Basic and Advanced Features .................................................................................... 48
Table 12. BMC Beep Codes ....................................................................................................... 52
Table 13. NMI Signal Generation and Event Logging ................................................................. 53
Table 14. Supported BMC FW Health Sensor Offsets ................................................................ 56
Table 15. Processor Sensors ...................................................................................................... 56
Table 16. Processor Status Sensor Implementation ................................................................... 56
Table 17. Supported ERR2 Timeout Sensor Offsets .................................................................. 58
Table 18. Supported CATERR Sensor Offsets ........................................................................... 59
Table 19. Support MSID Mismatch Sensor Offsets .................................................................... 59
Table 20. Supported Power Supply Status Sensor Offsets ........................................................ 62
Table 21. Support System Event Sensor Offsets ....................................................................... 63
Table 22. Supported Firmware Update Status Sensor Offsets ................................................... 64
Table 23. Standard Channel Assignments ................................................................................. 65
Table 24. Supported RMCP+ Cipher Suites ............................................................................... 66
Table 25. Supported RMCP+ Payload Types ............................................................................. 66
Table 26. Factory Configured PEF Table Entries ....................................................................... 71
Table 27. Enabling Advanced Management Features ................................................................ 77
Table 28. TSetup Utility Security Configuration Screen Fields ................................................ 86
Table 29. Main Power Connector Pin-out ................................................................................... 88
Table 30. CPU_1 Power Connector Pin-out ............................................................................... 88
Table 31. CPU_2 Power Connector Pin-out ............................................................................... 88
Table 32. Add-in Slot Power Pin-input ("OPT_12V_PWR") ........................................................ 89
Table 33. Front Panel Header Pin-out ........................................................................................ 89
Table 34. Front Panel USB Connector Pin-out ........................................................................... 90
Table 35. Local Front Panel Connector Pin-out .......................................................................... 90
Table 36. SATA 6Gbps Connector Pin-out ................................................................................. 90
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS List of Tables
Revision 1.2 Intel order number G34153-003
xi
Table 37. Multiport SAS/SATA Connector Pin-out ("SCU_0 (0-3)") ............................................ 91
Table 38. Multiport SAS/SATA Connector Pin-out ("SCU_1 (4-7)") ............................................ 91
Table 39. Intel® RAID C600 Upgrade Key Connector Pin-out .................................................... 92
Table 40. HSBP_I2C Header Pin-out ......................................................................................... 92
Table 41. HDD LED Header Pin-out ........................................................................................... 92
Table 42. Type-A USB Connector Pin-out .................................................................................. 92
Table 43. eUSB SSD Header Pin-out ......................................................................................... 93
Table 44. RMM4_Lite Connector Pin-out .................................................................................... 93
Table 45. RMM4_NIC Connector Pin-out ................................................................................... 93
Table 46. TPM Connector Pin-out .............................................................................................. 94
Table 47. PMBus* Connector Pin-out ......................................................................................... 94
Table 48. Chassis Intrusion Header Pin-out ............................................................................... 94
Table 49. IPMB Connector Pin-out ............................................................................................. 94
Table 50. 6-pin System FAN Connector Pin-out ......................................................................... 95
Table 51. 4-pin System FAN Connector Pin-out ......................................................................... 95
Table 52. CPU FAN Connector Pin-out ...................................................................................... 95
Table 53. Serial Port A Connector Pin-out .................................................................................. 95
Table 54. Serial Port B Connector Pin-out .................................................................................. 96
Table 55. Video Connector Pin-out details ................................................................................. 96
Table 56. Server Board Jumpers (J1C3, J1F1, J1F2, J 2F3, J2F2) ............................................ 98
Table 57. System Status LED ................................................................................................... 106
Table 58. POST Code Diagnostic LEDs ................................................................................... 107
Table 59. Server Board Design Specifications ......................................................................... 108
Table 60. Intel® Server Board S2600IP MTBF Estimate ........................................................... 109
Table 61. Intel® Workstation Board W2600CR MTBF Estimate ................................................ 109
Table 62. Intel® Xeon® Processor Dual Processor TDP profile ................................................. 112
Table 63. Minimum Load Ratings ............................................................................................. 112
Table 64. Loading Conditions ................................................................................................... 113
Table 65.Voltage Regulation Limits .......................................................................................... 113
Table 66. Transient Load Requirements ................................................................................... 113
Table 67. Capacitive Loading Conditions ................................................................................. 114
Table 68. Ripples and Noise ..................................................................................................... 115
Table 69. Output Voltage Timing .............................................................................................. 116
Table 70. Turn On/Off Timing ................................................................................................... 116
Table 71. Integrated BMC Core Sensors .................................................................................. 121
Table 72. Intel® Server Board S2600IP - BMC Channel Assignments ..................................... 140
Table 73. Intel® Server Board S2600IP - Chassis-specific Sensors ......................................... 141
Table 74. Intel® Server Board S2600IP - Fan Domain Definition .............................................. 142
Table 75. Intel® Server Chassis P4208/P4216/P4224/P4308 (UPL) Power support ................ 145
Table 76. Intel® Server Chassis R2208/R2216/R2224/R2308/R2312 (BHP) Power support ... 145
Table 77. Intel® Workstation Board W2600CR - BMC Channel Assignments .......................... 146
List of Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
xii
Table 78. Intel® Workstation Board W2600CR - Chassis-specific sensors ............................... 147
Table 79. Intel® Workstation Board W2600CR - Fan domain definition .................................... 147
Table 80. Intel® Server Chassis P4304 (UPL) Power support .................................................. 148
Table 81. POST Progress Code LED Example ........................................................................ 150
Table 82. POST Progress Codes ............................................................................................. 150
Table 83. MRC Progress Codes ............................................................................................... 152
Table 84. MRC Fatal Error Codes ............................................................................................ 153
Table 85. POST Error Codes and Messages ........................................................................... 155
Table 86. POST Error Beep Codes .......................................................................................... 160
Table 87. Integrated BMC Beep Codes .................................................................................... 161
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS List of Tables
Revision 1.2 Intel order number G34153-003
xiii
<This page is intentionally left blank.>
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Introduction
Revision 1.2 Intel order number G34153-003 1
1. Introduction
This Technical Product Specification (TPS) provides board-specific information detailing the features,
functionality, and high-level architecture of the Intel® Server Board S2600IP and Intel® Workstation Board
W2600CR.
In addition, you can obtain design-level information for a given subsystem by ordering the External
Product Specifications (EPS) for the specific subsystem. EPS documents are not publicly available and
you must order them through your local Intel representative.
1.1 Chapter Outline
This document is divided into the following chapters:
Chapter 1 Introduction
Chapter 2 Product Overview
Chapter 3 Functional Architecture
Chapter 4 Platform Management Overview
Chapter 5 System Security
Chapter 6 Connector/Header Locations and Pin-outs
Chapter 7 Jumper Blocks
Chapter 8 Intel® Light Guided Diagnostics
Chapter 9 Design and Environmental Specifications
Appendix A: Integration and Usage Tips
Appendix B: BMC Sensor Tables
Appendix C: Platform Specific BMC Appendix
Appendix D: POST Code Diagnostic LED Decoder
Appendix E: POST Error Messages and Handling
Glossary
Reference Documents
1.2 Server Board Use Disclaimer
Intel® Server Boards contain a number of high-density VLSI (Very-large-scale integration) and power
delivery components that require adequate airflow for cooling. Intel ensures through its own chassis
development and testing that when Intel® server building blocks are used together, the fully integrated
system meets the intended thermal requirements of these components. It is the responsibility of the
system integrator who chooses not to use Intel developed server building blocks to consult vendor
datasheets and operating parameters to determine the amount of airflow required for their specific
application and environmental conditions. Intel Corporation cannot be held responsible if components fail
or the server board does not operate correctly when used outside any of the published operating or non-
operating limits.
Product Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
2 Intel order number G34153-003 Revision 1.2
2. Product Overview
The Intel® Server Board S2600IP and Intel® Workstation Board W2600CR are Enterprise I/O Rich
platforms for Pedestal and Rack Server and workstation market.
Figure 1. Intel® Server Board S2600IP
Figure 2. Intel® Workstation Board W2600CR
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Product Overview
Revision 1.2 Intel order number G34153-003 3
2.1 Product Feature Set
Table 1. Product Feature Set
Board Name
Intel®
Server Board S2600IP
Intel®
Workstation Board W2600CR
Processors
Support for one or two Intel® Xeon® E5-
2600 Processor(s) and Intel® Xeon® E5-
2600 v2 Processor(s)
8 GT/s Intel® Quick Path Interconnect
(Intel® QPI)
LGA 2011 Socket
Thermal Design Power up to 135 W
Support for one or two Intel® Xeon® E5-
2600 Processor(s) and Intel® Xeon® E5-
2600 v2 Processor(s)
8 GT/s Intel® Quick Path Interconnect (Intel®
QPI)
LGA 2011 Socket
Thermal Design Power up to 150 W
Chipset
Intel® C600-A chipset with support for optional Intel® C600 RAID Upgrade Keys
Memory
16 DDR3 DIMMs with 800MT/s, 1067MT/s, 1333MT/s,1600MT/s, *1866MT/s
Eight memory channels (four channels for each processor socket)
Channels A, B, C, D, E, F, G and H
Support for Registered DDR3 Memory (RDIMM), Unbuffered DDR3 memory ((UDIMM) and
Load Reduced DDR3 memory (LRDIMM)
DDR3 standard I/O voltage of 1.5V and DDR3 Low Voltage of 1.35V
Slots
Slot 1: PCIe Gen3 x16, connector from first processor.
Slot 2: PCIe Gen3 x8, connector from first processor.
Slot 3: PCIe Gen3 x16, connector from first processor.
Slot 4: PCIe Gen3 x8, connector from second processor.
Slot 5: PCIe Gen3 x16, connector from second processor.
Slot 6: PCIe Gen3 x8, connector, from second processor
Slot 7: PCIe Gen3 x16,connector, from second processor
Slot 8: PCIe Gen2 x4 electrical with x8 physical connector, from second processor
IOM Connector: I/O Module (optional with Flex Cable*)
Notes: The IOM connector is not available for all boards and only supports PCIe Gen1 Speed
SM Conn: SAS Module (optional)
6Gbps or 12Gbps SAS ROC module Options
Ethernet
Intel® I350 Quad 1GbE fully integrated GbE
MAC and PHY Network Controller
Intel® I350 Dual 1GbE fully integrated GbE MAC
and PHY Controller
On-board storage
controllers and
options
One eUSB 2x5 pin connector to support 2mm low-profile eUSB solid state devices
Two 7-pin single port AHCI SATA connectors capable of supporting up to 6 GB/sec
Two SCU 4-port mini-SAS connectors capable of supporting up to 3 GB/sec SAS/SATA
Intel® Integrated RAID module support (Optional)
Intel® RAID C600 Upgrade Key support providing optional expanded SATA/SAS RAID
capabilities
Video
Integrated Matrox* G200 2D Video
Graphics controller
1 Rear VGA port
Integrated Matrox* G200 2D Video
Graphics controller
1 Internal VGA connector
Product Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
4 Intel order number G34153-003 Revision 1.2
Board Name
Intel®
Server Board S2600IP
Intel®
Workstation Board W2600CR
Audio
None
ALC889 HD Audio (7.1 + S/PDIF Out)
I/O
4 Rear USB2.0 1 Rear Serial A
2 Type A USB2.0 Connectors
1 Internal Serial B
4 Rear USB2.0 2 Rear USB3.0
2 Type A USB2.0 Connector
1 1394b Connector
1 Internal Serial B
Server
Management
Onboard Server Engines* LLC Pilot III* Controller
Support for Intel® Remote Management Module 4 solutions
Intel® Light-Guided Diagnostics on field replaceable units
Support for Intel® System Management Software
Support for Intel® Intelligent Power Node Manager (Need PMBus*-compliant power supply)
Security
Intel® Trusted Platform Module (TPM) - AXXTPME5 (accessory option)
Power-Supply
750W/1200W/1600W Common Redundant Power-Supply with PMBus* Support
Suspend to RAM
(S3)
None
Supported
Form Factor
Custom 14.2'' W x 15.0'' D
Chassis
Pedestal: P4000L chassis
2U Rack: R2000 chassis
Pedestal: P4000L WS chassis
*1866MT/s is only for Intel® Xeon® processor E5-2600 v2 product family
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Product Overview
Revision 1.2 Intel order number G34153-003 5
2.1.1 Main Board Connector and Component Layout
The following figure shows the layout of the server board. Each connector and major component is
identified by a number or letter, and a description is given below the figure.
Callout
Description
Callout
Description
A
Slot 1, PCI Express* Gen3
AD
DIMM C1/C2/D1/D2
B
RMM4 lite module connector
AE
System Fan connector 1/2/3/4/5/6
C
Slot 2, PCI Express* Gen3
AF
Type A USB connector
D
TPM
AG
Type A USB connector
E
Slot 3, PCI Express* Gen3
AH
ROC Module connector
F
Slot 4, PCI Express* Gen3
AI
LCP connector
G
RMM4 Connector
AJ
Front Panel connector
H
Slot 5, PCI Express* Gen3
AK
Front Panel USB connector
I
Battery
AL
Main Power 4-pin connector
J
Slot 6, PCI Express* Gen3
AM
MinISAS Port B(4-7)
K
Slot 7, PCI Express* Gen3
AN
MiniSAS Port A(0-3)
Product Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
6 Intel order number G34153-003 Revision 1.2
Callout
Description
Callout
Description
L
Slot 8, PCI Express* Gen2
AO
SATA Port 1
M
DIMM E1/E2/F1/F2
AP
SATA Port 0
N
Status LED
AQ
CPLD Update
O
ID LED
AR
IPMB
P
Diagnostic LED
AS
HDD LED
Q
NIC 3/4 (S2600IP only)
AT
ME FRC UPDT
R
USB 2/3, NIC 2
AU
CMOS CLR
S
USB 0/1, NIC 1
AV
BIOS RCVRY
T
VGA Port (S2600IP only)
AW
PASSWD CLR
U
Serial Port A (S2600IP only)
AX
Storage Upgrade Key
V
Processor 2 Power connector
AY
eUSB SSD
W
Processor 2 Fan connector
AZ
HSBP connector
X
DIMM H2/H1/G2/G1
BA
Chassis intrusion
Y
PMBus* connector
BB
Serial B connector
Z
Main Power connector
BC
BMC Force Update
AA
Processor 1 Power connector
BD
I/O Module connector (not available
for S2600IP4L)
AB
DIMM B2/B1/A2/A1
BE
System Fan connector 7
AC
Processor 1 Fan connector
Figure 3. Intel® Server Board S2600IP Major Components
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Product Overview
Revision 1.2 Intel order number G34153-003 7
Callout
Description
Callout
Description
A
Slot 1, PCI Express* Gen3
AE
DIMM C1/C2/D1/D2
B
RMM4 Lite module
AF
System Fan connector 1/2/3/4/5/6
C
Slot 2, PCI Express* Gen3
AG
Type A USB connector
D
TPM
AH
Type A USB connector
E
Slot 3, PCI Express* Gen3
AI
ROC Module connector
F
Slot 4, PCI Express* Gen3
AJ
LCP connector
G
RMM4 Connector
AK
Front Panel connector
H
Slot 5, PCI Express* Gen3
AL
Front Panel USB connector
I
Battery
AM
Main Power 4-pin connector
J
Slot 6, PCI Express* Gen3
AN
1394b connector(W2600CR only)
K
Slot 7, PCI Express* Gen3
AO
MiniSAS Port B(4-7)
L
Slot 8, PCI Express* Gen2
AP
MiniSAS Port A(0-3)
M
DIMM E1/E2/F1/F2
AQ
SATA Port 1
N
Status LED
AR
SATA Port 0
O
ID LED
AS
CPLD Update
P
Diagnostic LED
AT
IPMB
Product Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
8 Intel order number G34153-003 Revision 1.2
Callout
Description
Callout
Description
Q
SPDIF connector
AU
HDD LED
R
USB 2/3, NIC 2
AV
ME FRC UPDT
S
USB 0/1, NIC 1
AW
CMOS CLR
T
USB3.0 0/1(W2600CR only)
AX
BIOS RCVRY
U
HD Audio (W2600CR only)
AY
PASSWD CLR
V
Processor 2 Power connector
AZ
Storage Upgrade Key
W
Front Audio connector
BA
eUSB SSD
X
Processor 2 Fan connector
BB
HSBP connector
Y
DIMM H2/H1/G2/G1
BC
Chassis intrusion
Z
PMBus* connector
BD
Serial B connector
AA
Main Power connector
BE
BMC Force Update
AB
Processor 1 Power connector
BF
I/O Module connector (not available
for W2600CR2L)
AC
DIMM B2/B1/A2/A1
BG
Internal video connector
AD
Processor 1 Fan connector
BH
System Fan connector 7
Figure 3. Intel® Workstation Board W2600CR Major Components
2.1.2 Main Board Rear I/O Layout
The following drawing shows the layout of the rear I/O components for the server boards.
Callout
Description
Callout
Description
A
Serial Port A
E
NIC Port 3(top) and 4(bottom)
B
Video Port
F
Diagnostics LED’s
C
NIC Port 1, USB Port 0 (bottom) and 1
(top)
G
ID LED
D
NIC Port 2, USB Port 2 (bottom) and 3
(top)
H
Status LED
Figure 4. Intel® Server Board S2600IP Rear I/O Layout
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Product Overview
Revision 1.2 Intel order number G34153-003 9
Callout
Description
Callout
Description
A
7.1 Channel HD Audio Jack Connector
E
Diagnostics LED’s
B
USB3.0 Port 0(bottom) and 1(top)
F
ID LED
C
NIC Port 1, USB Port 0 (bottom) and 1
(top)
G
Status LED
D
NIC Port 2, USB Port 2 (bottom) and 3
(top)
Figure 5. Intel® Workstation Board W2600CR Rear I/O Layout
Product Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
10 Intel order number G34153-003 Revision 1.2
2.1.3 Server Board Mechanical Drawings
Figure 6. Mounting Hole Locations (1 of 2)
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Product Overview
Revision 1.2 Intel order number G34153-003 11
Figure 7. Mounting Hole Locations (2 of 2)
Product Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
12 Intel order number G34153-003 Revision 1.2
Figure 8. Major Connector Pin-1 Locations (1 of 3)
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Product Overview
Revision 1.2 Intel order number G34153-003 13
Figure 9. Major Connector Pin-1 Locations (2 of 3)
Product Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
14 Intel order number G34153-003 Revision 1.2
Figure 10. Major Connector Pin-1 Locations (3 of 3)
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Product Overview
Revision 1.2 Intel order number G34153-003 15
Product Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
16 Intel order number G34153-003 Revision 1.2
Figure 11. Primary Side Keep-out Zone
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Product Overview
Revision 1.2 Intel order number G34153-003 17
Figure 12. Primary Side Card-Side Keep-out Zone
Product Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
18 Intel order number G34153-003 Revision 1.2
Figure 13. Second Side Keep-out Zone
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 19
3. Functional Architecture
The architecture and design of the Intel® Server Board S2600IP and Intel® Workstation Board W2600CR
is based on the Intel® C600-A chipset. The chipset is designed for systems based on the Intel® Xeon®
Sandy Bridge-EP Processor series in an LGA 2011 Socket with Intel® Quick Path Interconnect (Intel® QPI)
speed at 8GT/s.
This chapter provides a high-level description of the functionality associated with each chipset component
and the architectural blocks that make up the server boards.
Figure 14. Intel® Server Board S2600IP Functional Block Diagram
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
20 Intel order number G34153-003 Revision 1.2
Figure 15. Intel® Workstation Board W2600CR Functional Block Diagram
3.1 Processor Support
The server board includes two Socket-R (LGA2011) processor sockets and can support one or two of the
following processors - Intel® Xeon® processor E5-2600 and E5-2600 v2 product family with a Thermal
Design Power (TDP) of up to 150W.
Note: The 150w TDP processor is only supported on Intel® Workstation Board W2600CR and Intel®
Server Board S2600IP only supports up to 135W TDP processors. Previous generation Intel® Xeon®
processors are not supported on the Intel server boards described in this document.
For a complete updated list of supported processors, please visit the support website.
3.1.1 Processor Socket Assembly
Each processor socket of the server board is pre-assembled with an Independent Latching Mechanism
(ILM) and Back Plate which allow for secure placement of the processor and processor heat to the server
board. The illustration below identifies each sub-assembly component.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 21
Figure 16. Processor Socket Assembly
Figure 17. Processor Socket ILM
The square ILM has an 80x80mm heat sink mounting hole pattern and is used on the Intel® Server Board
S2600IP and Intel® Workstation Board W2600CR.
Note: Processor Thermal solutions for the Intel® Workstation Board W2600CR are NOT the same with
Intel® Server Board S2600IP when install 150W TDP Processors.
3.1.2 Processor Population Rules
Note: Although the server board does support dual-processor configurations consisting of different
processors that meet the defined criteria below, Intel does not perform validation testing of this
configuration. For optimal system performance in dual-processor configurations, Intel recommends that
identical processors be installed.
Heat Sink
Server Board
Independent Latching
Mechanism (ILM)
Back Plate
80mm
80mm
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
22 Intel order number G34153-003 Revision 1.2
When using a single processor configuration, the processor must be installed into the processor socket
labeled CPU_1.
When two processors are installed, the following population rules apply:
Both processors must be of the same processor family.
Both processors must have the same number of cores.
Both processors must have the same cache sizes for all levels of processor cache
memory.
Processors with different core frequencies can be mixed in a system, given the prior
rules are met. If this condition is detected, all processor core frequencies are set to the
lowest common denominator (highest common speed) and an error is reported.
Processors which have different QPI link frequencies may operate together if they are
otherwise compatible and if a common link frequency can be selected. The common link
frequency would be the highest link frequency that all installed processors can achieve.
Processor stepping within a common processor family can be mixed as long as it is
listed in the processor specification updates published by Intel Corporation.
3.1.3 Processor Initialization Error Summary
The following table describes mixed processor conditions and recommended actions for all Intel®
server boards and Intel server systems designed around the Intel® Xeon® processor E5-2600 and E5-
2600 v2 product family and Intel® C600 chipset product family architecture. The errors fall into one of
the following three categories:
Fatal: If the system can boot, it pauses at a blank screen with the text “Unrecoverable
fatal error found. System will not boot until the error is resolved” and “Press <F2>
to enter setup”, regardless of whether the “Post Error Pause” setup option is enabled or
disabled.
When the operator presses the <F2> key on the keyboard, the error message is
displayed on the Error Manager screen, and an error is logged to the System Event Log
(SEL) with the POST Error Code.
The system cannot boot unless the error is resolved. The user needs to replace the
faulty part and restart the system.
For Fatal Errors during processor initialization, the System Status LED will be set to a
steady Amber color, indicating an unrecoverable system failure condition.
Major: If the “Post Error Pause” setup option is enabled, the system goes directly to the
Error Manager to display the error, and logs the POST Error Code to SEL. Operator
intervention is required to continue booting the system.
Otherwise, if “POST Error Pause” is disabled, the system continues to boot and no
prompt is given for the error, although the Post Error Code is logged to the Error
Manager and in a SEL message.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 23
Minor: The message is displayed on the screen or on the Error Manager screen, and
the POST Error Code is logged to the SEL. The system continues booting in a degraded
state. The user may want to replace the erroneous unit. The POST Error Pause option
setting in the BIOS setup does not have any effect on this error.
Table 2. Mixed Processor Configurations Error Summary.
Error
Severity
System Action
Processor family not Identical
Fatal
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the System Event Log (SEL).
Alerts the BMC to set the System Status LED to steady Amber.
Displays “0194: Processor family mismatch detected
message in the Error Manager.
Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Processor model not Identical
Fatal
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the System Event Log (SEL).
Alerts the BMC to set the System Status LED to steady Amber.
Displays “0196: Processor model mismatch detected
message in the Error Manager.
Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Processor cores/threads not identical
Fatal
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the SEL.
Alerts the BMC to set the System Status LED to steady Amber.
Displays “0191: Processor core/thread count mismatch
detected” message in the Error Manager.
Takes Fatal Error action (see above) and will not boot until the fault
condition is remedied.
Processor cache not identical
Fatal
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the SEL.
Alerts the BMC to set the System Status LED to steady Amber.
Displays “0192: Processor cache size mismatch detected
message in the Error Manager.
Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
24 Intel order number G34153-003 Revision 1.2
Error
Severity
System Action
Processor frequency (speed) not
identical
Fatal
The BIOS detects the processor frequency difference, and responds
as follows:
Adjusts all processor frequencies to the highest common
frequency.
No error is generated this is not an error condition.
Continues to boot the system successfully.
If the frequencies for all processors cannot be adjusted to be the
same, then this is an error, and the BIOS responds as follows:
Logs the POST Error Code into the SEL.
Alerts the BMC to set the System Status LED to steady Amber.
Does not disable the processor.
Displays “0197: Processor speeds unable to synchronize
message in the Error Manager.
Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Processor Intel® QuickPath
Interconnect link frequencies not
identical
Fatal
The BIOS detects the QPI link frequencies and responds as follows:
Adjusts all QPI interconnect link frequencies to highest common
frequency.
No error is generated this is not an error condition.
Continues to boot the system successfully.
If the link frequencies for all QPI links cannot be adjusted to be the
same, then this is an error, and the BIOS responds as follows:
Logs the POST Error Code into the SEL.
Alerts the BMC to set the System Status LED to steady Amber.
Displays “0195: Processor Intel(R) QPI link frequencies
unable to synchronize” message in the Error Manager.
Does not disable the processor.
Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Processor microcode update missing
Minor
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the SEL.
Displays “818x: Processor 0x microcode update not found
message in the Error Manager or on the screen.
The system continues to boot in a degraded state, regardless of
the setting of POST Error Pause in the Setup.
Processor microcode update failed
Major
The BIOS detects the error condition and responds as follows:
Logs the POST Error Code into the SEL.
Displays “816x: Processor 0x unable to apply microcode
update” message in the Error Manager or on the screen.
Takes Major Error action. The system may continue to boot in a
degraded state, depending on the setting of POST Error Pause in
Setup, or may halt with the POST Error Code in the Error Manager
waiting for operator intervention.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 25
3.2 Processor Functions Overview
With the release of the Intel® Xeon® processor E5-2600 and E5-2600 v2 product family, several
key system components, including the CPU, Integrated Memory Controller (IMC), and
Integrated IO Module (IIO), have been combined into a single processor package and feature
per socket; two Intel® QuickPath Interconnect point-to-point links capable of up to 8.0 GT/s, up to
40 lanes of Gen 3 PCI Express* links capable of 8.0 GT/s, and 4 lanes of DMI2/PCI Express*
Gen 2 interface with a peak transfer rate of 5.0 GT/s. The processor supports up to 46 bits of
physical address space and 48-bit of virtual address space.
The following sections will provide an overview of the key processor features and functions that
help to define the performance and architecture of the server board. For more comprehensive
processor specific information, refer to the Intel® Xeon® processor E5-2600 and E5-2600 v2
product family documents listed in the Reference Document list.
Processor Feature Details:
Up to 8 execution cores for Intel® Xeon® processor E5-2600 product family
Up to 12 execution cores for Intel ® Xeon® processor E5-2600 v2 product family
Each core supports two threads (Intel® Hyper-Threading Technology), up to 16 threads
per socket for E5-2600 and 24 threads per socket for E5-2600 v2
46-bit physical addressing and 48-bit virtual addressing
1 GB large page support for server applications
A 32-KB instruction and 32-KB data first-level cache (L1) for each core
A 256-KB shared instruction/data mid-level (L2) cache for each core
Up to 20 MB last level cache (LLC) for E5-2600: up to 2.5 MB per core instruction/data
last level cache (LLC), shared among all cores
Up to 30 MB last level cache (LLC) for E5-2600 v2: up to 2.5 MB per core
instruction/data last level cache (LLC), shared among all cores
Supported Technologies:
Intel® Virtualization Technology (Intel® VT)
Intel® Virtualization Technology for Directed I/O (Intel® VT-d)
Intel® Virtualization Technology “Sandy Bridge” Processor Extensions
Intel® Trusted Execution Technology (Intel® TXT)
Intel® 64 Architecture
Intel® Streaming SIMD Extensions 4.1 (Intel® SSE4.1)
Intel® Streaming SIMD Extensions 4.2 (Intel® SSE4.2)
Intel® Advanced Vector Extensions (Intel® AVX)
Intel® Hyper-Threading Technology
Execute Disable Bit
Intel® Turbo Boost Technology
Intel® Intelligent Power Technology
Enhanced Intel® SpeedStep Technology
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
26 Intel order number G34153-003 Revision 1.2
3.2.1 Intel® QuickPath Interconnect
The Intel® QuickPath Interconnect is a high speed, packetized, point-to-point interconnect used
in the processor. The narrow high-speed links stitch together processors in distributed shared
memory and integrated I/O platform architecture. It offers much higher bandwidth with low
latency. The Intel® QuickPath Interconnect has an
efficient
architecture
allowing more
interconnect performance to be achieved in real systems. It has a snoop protocol optimized for
low latency and high scalability, as well as packet and lane structures enabling quick
completions of transactions. Reliability, availability, and serviceability features (RAS) are built into
the architecture.
The physical connectivity of each interconnect link is made up of twenty differential signal pairs
plus a differential forwarded clock. Each port supports a link pair consisting of two unidirectional
links to complete the connection between two components. This supports traffic in both
directions simultaneously. To facilitate flexibility and longevity, the interconnect is defined as
having five layers: Physical, Link, Routing, Transport, and Protocol.
The Intel® QuickPath Interconnect includes a cache coherency protocol to keep the distributed
memory and caching structures coherent during system operation. It supports both low-latency
source snooping and a scalable home snoop behavior. The coherency protocol provides for
direct cache-to-cache transfers for optimal latency.
3.2.2 Integrated Memory Controller (IMC) and Memory Subsystem
Integrated into the processor is a memory controller. Each processor provides four DDR3 channels that
support the following:
Unbuffered DDR3 and registered DDR3 DIMMs
LR DIMM (Load Reduced DIMM) for buffered memory solutions demanding higher
capacity memory subsystems
Independent channel mode or lockstep mode
Data burst length of eight cycles for all memory organization modes
Memory DDR3 data transfer rates of 800, 1066, 1333, 1600 and 1866* MT/s
64-bit wide channels plus 8-bits of ECC support for each channel
DDR3 standard I/O Voltage of 1.5 V and DDR3 Low Voltage of 1.35 V
1-Gb, 2-Gb, and 4-Gb DDR3 DRAM technologies supported for these devices:
o UDIMM DDR3 SR x8 and x16 data widths, DR x8 data width
o RDIMM DDR3 SR,DR, and QR x4 and x8 data widths
o LRDIMM DDR3 QR x4 and x8 data widths with direct map or with rank multiplication
CPU 2
CPU 1
2 DIMMs/Ch
2 DIMMs/Ch
Figure 18. Integrated Memory Controller Functional Block Diagram
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 27
Up to 8 ranks supported per memory channel, 1, 2 or 4 ranks per DIMM
Open with adaptive idle page close timer or closed page policy
Per channel memory test and initialization engine can initialize DRAM to all logical zeros
with valid ECC (with or without data scrambler) or a predefined test pattern
Isochronous access support for Quality of Service (QoS)
Minimum memory configuration: independent channel support with 1 DIMM populated
Integrated dual SMBus* master controllers
Command launch modes of 1n/2n
RAS Support:
o Rank Level Sparing and Device Tagging
o Demand and Patrol Scrubbing
o DRAM Single Device Data Correction (SDDC) for any single x4 or x8 DRAM device.
Independent channel mode supports x4 SDDC. x8 SDDC requires lockstep mode
o Lockstep mode where channels 0 and 1 and channels 2 and 3 are operated in
lockstep mode
o Data scrambling with address to ease detection of write errors to an incorrect address.
o Error reporting from Machine Check Architecture
o Read Retry during CRC error handling checks by iMC
o Channel mirroring within a socket
CPU1 Channel Mirror Pairs (A,B) and (C,D)
CPU2 Channel Mirror Pairs (E,F) and (G,H)
o Error Containment Recovery
Improved Thermal Throttling with dynamic Closed Loop Thermal Throttling (CLTT)
Memory thermal monitoring support for DIMM temperature
*1866MT/s is only supported for E5-2600 v2 product family
3.2.2.1 Supported Memory
Table 3. UDIMM Support Guidelines
Ranks Per
DIMM and
Data Width
Memory Capacity Per
DIMM1
Speed (MT/s) and Voltage Validated by
Slot per Channel (SPC) and DIMM Per Channel (DPC)2,3
2 Slots per Channel
1DPC
2DPC
1.35V
1.5V
1.35V
1.5V
Intel® Xeon® processor E5-2600 product family
SRx8
ECC
1GB
2GB
4GB
1066,1333
1066, 1333
1066
1066, 1333
DRx8
ECC
2GB
4GB
8GB
1066,1333
1066, 1333
1066
1066, 1333
Intel® Xeon® processor E5-2600 v2 product family
SRx8
ECC
1GB
2GB
4GB
1066,1333
1066, 1333,
1600, 1866
1066, 1333
1066, 1333, 1600
DRx8
ECC
2GB
4GB
8GB
1066,1333
1066, 1333,
1600,1866
1066, 1333
1066, 1333, 1600
Notes:
1. Supported DRAM Densities are 1Gb, 2Gb and 4Gb. Only 2Gb and 4Gb are validated by Intel.
2. Command Address Timing is 1N for 1DPC and 2N for 2DPC.
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
28 Intel order number G34153-003 Revision 1.2
Supported and Validated
Supported but not Validate
Table 4. RDIMM Support Guidelines
Ranks Per DIMM
and Data Width
Memory Capacity Per DIMM1
Speed (MT/s) and Voltage Validated by
Slot per Channel (SPC) and DIMM Per Channel (DPC)2
2 Slots per Channel
1DPC
2DPC
1.35V
1.5V
1.35V
1.5V
Intel® Xeon® processor E5-2600 product family
SRx8
1GB
2GB
4GB
1066, 1333
1066, 1333, 1600
1066, 1333
1066, 1333, 1600
DRx8
2GB
4GB
8GB
1066, 1333
1066, 1333, 1600
1066, 1333
1066, 1333, 1600
SRx4
2GB
4GB
8GB
1066, 1333
1066, 1333, 1600
1066, 1333
1066, 1333, 1600
DRx4
4GB
8GB
16GB
1066, 1333
1066, 1333, 1600
1066, 1333
1066, 1333, 1600
QRx4
8GB
16GB
32GB
800
1066
800
800
QRx8
4GB
8GB
16GB
800
1066
800
800
Intel® Xeon® processor E5-2600 v2 product family
SRx8
1GB
2GB
4GB
1066, 1333
1066, 1333, 1600,
1866
1066 1333
1066, 1333, 1600
DRx8
2GB
4GB
8GB
1066, 1333
1066, 1333, 1600,
1866
1066 1333
1066, 1333, 1600
SRx4
2GB
4GB
8GB
1066, 1333
1066, 1333, 1600,
1866
1066 1333
1066, 1333, 1600
DRx4
4GB
8GB
16GB
1066, 1333
1066, 1333, 1600,
1866
1066 1333
1066, 1333, 1600
QRx4
8GB
16GB
32GB
800
1066
800
800
QRx8
4GB
8GB
16GB
800
1066
800
800
Notes:
1. Supported DRAM Densities are 1Gb, 2Gb and 4Gb. Only 2Gb and 4Gb are validated by Intel®.
2. Command Address Timing is 1N.
3. QR RDIMM are supported but only validated by Intel/PMO in a homogenous environment. The coverage will
have limited system level testing, no signal integrity testing, and no interoperability testing the passing QR
RDIMMs will be web posted.
Supported and Validated
Supported but not Validate
Supported w/Limited Validation4
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 29
Table 5. LRDIMM Support Guidelines
Ranks
Per
DIMM
and
Data
Width1
Memory Capacity
Per DIMM2
Speed (MT/s) and Voltage Validated by
Slot per Channel (SPC) and DIMM Per Channel (DPC)3,4
2 Slots per Channel
1DPC
2DPC
1.35V
1.5V
1.35V
1.5V
Intel® Xeon® processor E5-2600 product family
QRx4
(DDP)5
16GB
32GB
1066
1066, 1333
1066
1066, 1333
QRx8
(P)5
8GB
16GB
1066
1066, 1333
1066
1066, 1333
Intel® Xeon® processor E5-2600 v2 product family
QRx4
(DDP)5
16GB
32GB
1066, 1333
1066, 1333
1066, 1333
1066, 1333
QRx8
(P)5
32GB
64GB
1066
1066
1066
1066
Notes:
1. Physical Rank is used to calculate DIMM Capacity.
2. Supported and validated DRAM Densities are 2Gb and 4Gb.
3. Command Address Timing is 1N.
4. The speeds are estimated targets and will be verified through simulation.
5. DDP - Dual Die Package DRAM stacking. P Planer monolithic DRAM Die.
Supported and Validated
3.2.2.2 Memory Population Rules
Note: Although mixed DIMM configurations are supported, Intel only performs platform
validation on systems that are configured with identical DIMMs installed.
Each processor provides four banks of memory, each capable of supporting up to 2 DIMMs.
DIMMs are organized into physical slots on DDR3 memory channels that belong to processor
sockets.
The memory channels from processor socket 1 are identified as Channel A, B, C and D. The
memory channels from processor socket 2 are identified as Channel E, F, G, and H.
The silk screened DIMM slot identifiers on the board provide information about the channel, and
therefore the processor to which they belong. For example, DIMM_A1 is the first slot on Channel
A on processor 1; DIMM_E1 is the first DIMM socket on Channel E on processor 2.
The memory slots associated with a given processor are unavailable if the corresponding
processor socket is not populated.
A processor may be installed without populating the associated memory slots provided a second
processor is installed with associated memory. In this case, the memory is shared by the
processors. However, the platform suffers performance degradation and latency due to the
remote memory.
Processor sockets are self-contained and autonomous. However, all memory subsystem support
(such as Memory RAS, Error Management,) in the BIOS setup are applied commonly across
processor sockets.
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
30 Intel order number G34153-003 Revision 1.2
On the Intel® Server Board S2600IP and Intel® Workstation Board W2600CR a total of 16 DIMM slots is
provided (2 CPUs 4 Channels/CPU, 2 DIMMs/Channel). The nomenclature for DIMM sockets is detailed
in the following table:
Table 6. DIMM Nomenclature
Processor Socket 1
Processor Socket 2
(0)
Channel A
(1)
Channel B
(2)
Channel C
(3)
Channel D
(0)
Channel E
(1)
Channel F
(2)
Channel G
(3)
Channel H
A1
A2
B1
B2
C1
C2
D1
D2
E1
E2
F1
F2
G1
G2
H1
H2
Figure 19. DIMM Slot Layout
The following are generic DIMM population requirements that generally apply to both the Intel® Server
Board S2600IP and Intel® Workstation Board W2600CR.
DIMM slots on any memory channel must be filled following the “farthest fill first” rule.
A maximum of 8 ranks can be installed on any one channel, counting all ranks in each DIMM on
the channel.
DIMM types (UDIMM, RDIMM, LRDIMM) must not be mixed within or across processor sockets.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 31
Mixing ECC with non-ECC DIMMs (UDIMMs) is not supported within or across processor sockets.
Mixing Low Voltage (1.35V) DIMMs with Standard Voltage (1.5V) DIMMs is not supported within
or across processor sockets.
Mixing DIMMs of different frequencies and latencies is not supported within or across processor
sockets.
LRDIMM Rank Multiplication Mode and Direct Map Mode must not be mixed within or across
processor sockets.
Only ECC UDIMMs support Low Voltage 1.35V operation.
QR RDIMMs may only be installed in DIMM Slot 1 or 2 on a channel.
2 DPC QR Low Voltage RDIMMs are not supported.
In order to install 3 QR LRDIMMs on the same channel, they must be operated with Rank
Multiplication as RM = 2.
RAS Modes Lockstep, Rank Sparing, and Mirroring are mutually exclusive in this BIOS. Only one
operating mode may be selected, and it will be applied to the entire system.
If a RAS Mode has been configured, and the memory population will not support it during boot,
the system will fall back to Independent Channel Mode and log and display errors
Rank Sparing Mode is only possible when all channels that are populated with memory meet the
requirement of having at least 2 SR or DR DIMM installed, or at least one QR DIMM installed, on
each populated channel.
Lockstep or Mirroring Modes require that for any channel pair that is populated with memory, the
memory population on both channels of the pair must be identically sized.
DIMM population rules require that DIMMs within a channel be populated starting with the BLUE
DIMM slot or DIMM farthest from the processor in a “fill-farthest” approach. In addition, when
populating a Quad-rank DIMM with a Single- or Dual-rank DIMM in the same channel, the
Quad-rank DIMM must be populated farthest from the processor. Note that Quad-rand DIMMs
and UDIMMs are not allowed in three slots populated configurations. Intel MRC will check for
correct DIMM placement.
3.2.2.3 Publishing System Memory
The BIOS displays the “Total Memory” of the system during POST if Display Logo is disabled in
the BIOS setup. This is the total size of memory discovered by the BIOS during POST, and is the
sum of the individual sizes of installed DDR3 DIMMs in the system.
The BIOS displays the “Effective Memory” of the system in the BIOS setup. The term Effective
Memory refers to the total size of all DDR3 DIMMs that are active (not disabled) and not used as
redundant units.
The BIOS provides the total memory of the system in the main page of the BIOS setup. This total
is the same as the amount described by the first bullet above.
If Quite Boot is disabled, the BIOS displays the total system memory on the diagnostic screen at the end
of POST. This total is the same as the amount described by the first bullet above.
3.2.2.4 RAS Features
The server board supports the following memory RAS modes:
Independent Channel Mode
Rank Sparing Mode
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
32 Intel order number G34153-003 Revision 1.2
Mirrored Channel Mode
Lockstep Channel Mode
Regardless of RAS mode, the requirements for populating within a channel given in the section 3.2.2.2
must be met at all times. Note that support of RAS modes that require matching DIMM population
between channels (Mirrored and Lockstep) require that ECC DIMMs be populated. Independent Channel
Mode is the only mode that supports non-ECC DIMMs in addition to ECC DIMMs.
For RAS modes that require matching populations, the same slot positions across channels must hold the
same DIMM type with regards to size and organization. DIMM timings do not have to match but timings
will be set to support all DIMMs populated (that is, DIMMs with slower timings will force faster DIMMs to
the slower common timing modes).
3.2.2.4.1 Independent Channel Mode
Channels can be populated in any order in Independent Channel Mode. All four channels may be
populated in any order and have no matching requirements. All channels must run at the same interface
frequency but individual channels may run at different DIMM timings (RAS latency, CAS Latency, and so
forth).
3.2.2.4.2 Rank Sparing Mode
In Rank Sparing Mode, one rank is a spare of the other ranks on the same channel. The spare rank is
held in reserve and is not available as system memory. The spare rank must have identical or larger
memory capacity than all the other ranks (sparing source ranks) on the same channel. After sparing, the
sparing source rank will be lost.
3.2.2.4.3 Mirrored Channel Mode
In Mirrored Channel Mode, the memory contents are mirrored between Channel 0 and Channel 2
and also between Channel 1 and Channel 3. As a result of the mirroring, the total physical
memory available to the system is half of what is populated. Mirrored Channel Mode requires
that Channel 0 and Channel 2, and Channel 1 and Channel 3 must be populated identically with
regards to size and organization. DIMM slot populations within a channel do not have to be
identical but the same DIMM slot location across Channel 0 and Channel 2 and across Channel
1 and Channel 3 must be populated the same.
3.2.2.4.4 Lockstep Channel Mode
In Lockstep Channel Mode, each memory access is a 128-bit data access that spans Channel 0
and Channel 1, and Channel 2 and Channel 3. Lockstep Channel mode is the only RAS mode
that allows SDDC for x8 devices. Lockstep Channel Mode requires that Channel 0 and Channel
1, and Channel 2 and Channel 3 must be populated identically with regards to size and
organization. DIMM slot populations within a channel do not have to be identical but the same
DIMM slot location across Channel 0 and Channel 1 and across Channel 2 and Channel 3 must
be populated the same.
3.2.3 Processor Integrated I/O Module (IIO)
The processor’s integrated I/O module provides features traditionally supported through chipset
components. The integrated I/O module provides the following features:
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 33
3.2.3.1 PCI Express* Interfaces
The integrated I/O module incorporates the PCI Express* interface and supports up to 40 lanes of
PCI Express*. Following are key attributes of the PCI Express* interface:
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR supports PCI-e slots from two
processors:
From first processor:
Slot 1: PCIe Gen3 x16 connector
Slot 2: PCIe Gen3 x8 connector
Slot 3: PCIe Gen3 x16 connector
From second processor:
Slot 4: PCIe Gen3 x8 connector
Slot 5: PCIe Gen3 x16 connector
Slot 6: PCIe Gen3 x8 connector
Slot 7: PCIe Gen3 x16 connector
Slot 8: PCIe Gen2 x4 electrical with x8 physical connector.
Note: System will have video output on PCIe slots from first processor by default. If need add-in video
card output on slots from second processor, please refer System Service guide to change Bios setup.
3.2.3.2 DMI2 Interface to the PCH
The platform requires an interface to the legacy Southbridge (PCH) which provides basic legacy
functions required for the server platform and operating systems. Since only one PCH is required
and allowed for the system, any sockets which do not connect to PCH would use this port as a
standard x4 PCI Express* 2.0 interface.
3.2.3.3 Integrated IOAPIC
Provides support for PCI Express* devices implementing legacy interrupt messages without interrupt
sharing.
3.2.3.4 Non Transparent Bridge
PCI Express* non-transparent bridge (NTB) acts as a gateway that enables high performance, low
overhead communication between two intelligent subsystems; the local and the remote subsystems.
The NTB allows a local processor to independently configure and control the local subsystem,
provides isolation of the local host memory domain from the remote host memory domain while
enabling status and data exchange between the two domains.
3.2.3.5 4.2.3.1.5 Intel®
QuickData Technology
Used for efficient, high bandwidth data movement between two locations in memory or from
memory to I/O.
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
34 Intel order number G34153-003 Revision 1.2
3.3 Intel®
C600-A Chipset Functional overview
The Intel® C600-A Chipset in the Intel® Server Board S2600IP and Intel® Workstation Board W2600CR
provide a connection point between various I/O components and Intel® Xeon Sandy Bridge-EP
processors, which includes the following core platform functions:
Digital Media Interface (DMI)
PCI Express* Interface
Serial ATA (SATA) Controller
Serial Attached SCSI (SAS)/SATA Controller
AHCI
Rapid Storage Technology
PCI Interface
Low Pin Count (LPC) Interface
Serial Peripheral Interface (SPI)
Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)
Advanced Programmable Interrupt Controller (APIC)
Universal Serial Bus (USB) Controllers
Gigabit Ethernet Controller
RTC
GPIO
Enhanced Power Management
Intel® Active Management Technology (Intel® AMT)
Manageability
System Management Bus (SMBus* 2.0)
Integrated NVSRAM controller
Virtualization Technology for Directed I/O (Intel® VT-d)
JTAG Boundary-Scan
KVM/Serial Over LAN (SOL) Function
3.3.1 Digital Media Interface (DMI)
Digital Media Interface (DMI) is the chip-to-chip connection between the processor and The Intel® C600-A
Chipset. This high-speed interface integrates advanced priority-based servicing allowing for concurrent
traffic and true isochronous transfer capabilities. Base functionality is completely software-transparent,
permitting current and legacy software to operate normally.
3.3.2 PCI Express* Interface
The Intel® C600-A Chipset provides up to 8 PCI Express* Root Ports, supporting the PCI Express* Base
Specification, Revision 2.0. Each Root Port x1 lane supports up to 5 Gb/s bandwidth in each direction (10
Gb/s concurrent). PCI Express* Root Ports 1-4 or Ports 5-8 can independently be configured to support
four x1s, two x2s, one x2 and two x1s, or one x4 port widths.
3.3.3 Serial ATA (SATA) Controller
The Intel® C600-A Chipset has two integrated SATA host controllers that support independent DMA
operation on up to six ports and supports data transfer rates of up to 6.0 Gb/s (600 MB/s) on up to two
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 35
ports (Port 0 and 1 Only) while all ports support rates up to 3.0 Gb/s (300 MB/s) and up to 1.5 Gb/s (150
MB/s). The SATA controller contains two modes of operation a legacy mode using I/O space, and an
AHCI mode using memory space. Software that uses legacy mode will not have AHCI capabilities.
The Intel® C600-A Chipset supports the Serial ATA Specification, Revision 3.0. The Intel® C600-A
Chipset also supports several optional sections of the Serial ATA II: Extensions to Serial ATA 1.0
Specification, Revision 1.0 (AHCI support is required for some elements).
3.3.4 Serial Attached SCSI (SAS)/SATA (SCU) Controller
The Intel® C600-A Chipset supports up to 8 SAS ports that are compliant with SAS 2.0 Specification and
all ports support rates up to 3.0 Gb/s. All 8 ports are also independently configurable and compliant with
SATA Gen2 and support data transfer rates of up to 3.0 Gb/s.
SAS/SATA controller is only available on specific Intel® C600-A Chipset SKUs with optional RAID C600
Upgrade key. Certain SKUs are also limited to support 4 of 8 SAS/SATA ports only. Please refer details
below:
Note: SAS/SATA (SCU) port 0-3 is by default enabled while port 4-7 is disabled.
Table 7. Intel® RAID C600 Upgrade Key Options
Intel®
RAID C600 Upgrade Key Options
(Product Codes)
Key Color
Description
Default No option key installed
N/A
4 Port SATA with Intel® ESRT RAID 0,1,10 and Intel®
RSTe RAID 0,1,5,10
RKSATA4R5
Black
4 Port SATA with Intel® ESRT2 RAID 0,1, 5, 10 and Intel®
RSTe RAID 0,1,5,10
RKSATA8
Blue
8 Port SATA with Intel® ESRT2 RAID 0,1, 10 and Intel®
RSTe RAID 0,1,5,10
RKSATA8R5
White
8 Port SATA with Intel® ESRT2 RAID 0,1, 5, 10 and Intel®
RSTe RAID 0,1,5,10
RKSAS4
Green
4 Port SAS with Intel® ESRT2 RAID 0,1, 10 and Intel®
RSTe RAID 0,1,10
RKSAS4R5
Yellow
4 Port SAS with Intel® ESRT2 RAID 0,1, 5, 10 and Intel®
RSTe RAID 0,1,10
RKSAS8
Orange
8 Port SAS with Intel® ESRT2 RAID 0,1, 10 and Intel®
RSTe RAID 0,1,10
RKSAS8R5
Purple
8 Port SAS with Intel® ESRT2 RAID 0,1, 5, 10 and Intel®
RSTe RAID 0,1,10
Additional information for the on-board RAID features and functionality can be found in the Intel®
RAID Software Users Guide (Intel Document Number D29305-019).
3.3.5 AHCI
The Intel® C600-A Chipset provides hardware support for Advanced Host Controller Interface (AHCI), a
standardized programming interface for SATA host controllers. Platforms supporting AHCI may take
advantage of performance features. AHCI also provides usability enhancements such as Hot-Plug. AHCI
requires appropriate software support (for example, an AHCI driver) and for some features, hardware
support in the SATA device or additional platform hardware.
3.3.6 Rapid Storage Technology
The Intel® C600-A Chipset provides support for Intel® Rapid Storage Technology, providing both AHCI
and integrated RAID functionality. The RAID capability provides high-performance RAID 0, 1, 5 and 10
functionality on the Intel® C600-A chipset. Matrix RAID support is provided to allow multiple RAID levels to
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
36 Intel order number G34153-003 Revision 1.2
be combined on a single set of hard drives, such as RAID 0 and RAID 1 on two disks. Other RAID
features include hot-spare support, SMART alerting, and RAID 0 auto replace.
3.3.7 PCI Interface
The Intel® C600-A chipset PCI interface provides a 33 MHz, Revision 2.3 implementation. The Intel®
C600-A chipset integrates a PCI arbiter that supports up to four external PCI bus masters in addition to
the internal Intel® C600-A chipset requests. This allows for combinations of up to four PCI down devices
and PCI slots.
3.3.8 Low Pin Count (LPC) Interface
The Intel® C600-A chipset implements an LPC Interface as described in the LPC 1.1 Specification. The
Low Pin Count (LPC) bridge function of the Intel® C600-A resides in PCI Device 31: Function 0. In
addition to the LPC bridge interface function, D31:F0 contains other functional units including DMA,
interrupt controllers, timers, power management, system management, GPIO, and RTC.
3.3.9 Serial Peripheral Interface (SPI)
The Intel® C600-A chipset implements an SPI Interface as an alternative interface for the BIOS flash
device. The SPI flash is required to support Gigabit Ethernet and Intel® Active Management Technology.
The Intel® C600-A chipset supports up to two SPI flash devices with speeds up to 50 MHz.
3.3.10 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)
The DMA controller incorporates the logic of two 82C37 DMA controllers, with seven independently
programmable channels. The Intel® C600-A chipset supports LPC DMA through the Intel® C600-A
chipset’s DMA controller.
The timer/counter block contains three counters that are equivalent in function to those found in one
82C54 programmable interval timer. These three counters are combined to provide the system timer
function, and speaker tone.
The Intel® C600-A chipset provides an ISA-Compatible Programmable Interrupt Controller (PIC) that
incorporates the functionality of two 82C59 interrupt controllers. In addition, the Intel® C600-A chipset
supports a serial interrupt scheme.
All of the registers in these modules can be read and restored. This is required to save and restore
system state after power has been removed and restored to the platform.
3.3.11 Advanced Programmable Interrupt Controller (APIC)
In addition to the standard ISA compatible Programmable Interrupt controller (PIC) described in the
previous section, the Intel® C600-A incorporates the Advanced Programmable Interrupt Controller (APIC).
3.3.12 Universal Serial Bus (USB) Controllers
The Intel® C600-A chipset has up to two Enhanced Host Controller Interface (EHCI) host controllers that
support USB high-speed signaling. High-speed USB 2.0 allows data transfers up to 480 Mb/s which is 40
times faster than full-speed USB. The Intel® C600-A chipset supports up to fourteen USB 2.0 ports. All
fourteen ports are high-speed, full-speed, and low-speed capable.
3.3.13 Gigabit Ethernet Controller
The Gigabit Ethernet Controller provides a system interface using a PCI function. The controller provides
a full memory-mapped or IO mapped interface along with a 64 bit address master support for systems
using more than 4 GB of physical memory and DMA (Direct Memory Addressing) mechanisms for high
performance data transfers. Its bus master capabilities enable the component to process high-level
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 37
commands and perform multiple operations; this lowers processor utilization by off-loading
communication tasks from the processor. Two large configurable transmit and receive FIFOs (up to 20 KB
each) help prevent data underruns and overruns while waiting for bus accesses. This enables the
integrated LAN controller to transmit data with minimum interframe spacing (IFS).
The LAN controller can operate at multiple speeds (10/100/1000 MB/s) and in either full duplex or half
duplex mode. In full duplex mode the LAN controller adheres with the IEEE 802.3x Flow Control
Specification. Half duplex performance is enhanced by a proprietary collision reduction mechanism.
3.3.14 RTC
The Intel® C600-A chipset contains a real-time clock with 256 bytes of battery-backed RAM. The real-time
clock performs two key functions: keeping track of the time of day and storing system data. The RTC
operates on a 32.768 KHz crystal and a 3 V battery.
3.3.15 GPIO
Various general purpose inputs and outputs are provided for custom system design. The number of
inputs and outputs varies depending on the Intel® C600-A chipset configuration.
3.3.16 Enhanced Power Management
The Intel® C600-A chipset’s power management functions include enhanced clock control and various
low-power (suspend) states (for example, Suspend-to-RAM and Suspend-to-Disk). A hardware-based
thermal management circuit permits software-independent entrance to low-power states. The Intel® C600-
A chipset contains full support for the Advanced Configuration and Power Interface (ACPI) Specification,
Revision 4.0a.
3.3.17 Manageability
In addition to Intel AMT the Intel® C600-A chipset integrates several functions designed to manage the
system and lower the total cost of ownership (TCO) of the system. These system management functions
are designed to report errors, diagnose the system, and recover from system lockups without the aid of
an external microcontroller.
3.3.18 System Management Bus (SMBus* 2.0)
The Intel® C600-A chipset contains a SMBus* Host interface that allows the processor to communicate
with SMBus* slaves. This interface is compatible with most I2C devices. Special I2C commands are
implemented.
The Intel® C600-A chipset’s SMBus* host controller provides a mechanism for the processor to initiate
communications with SMBus* peripherals (slaves). Also, the Intel® C600-A chipset supports slave
functionality, including the Host Notify protocol. Hence, the host controller supports eight command
protocols of the SMBus* interface (see System Management Bus (SMBus*) Specification, Version 2.0):
Quick Command, Send Byte, Receive Byte, Write Byte/Word, Read Byte/Word, Process Call, Block
Read/Write, and Host Notify.
The Intel® C600-A chipset’s SMBus* also implements hardware-based Packet Error Checking for data
robustness and the Address Resolution Protocol (ARP) to dynamically provide address to all SMBus*
devices.
3.3.19 Integrated NVSRAM controller
The Intel® C600-A chipset has an integrated NVSRAM controller that supports up to 32KB external device.
The host processor can read and write data to the NVSRAM component.
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
38 Intel order number G34153-003 Revision 1.2
3.3.20 Virtualization Technology for Directed I/O (Intel® VT-d)
The Intel® C600-A chipset provides hardware support for implementation of Intel® Virtualization
Technology with Directed I/O (Intel® VT-d). Intel VT-d consists of technology components that support the
virtualization of platforms based on Intel® Architecture Processors. Intel VT-d Technology enables
multiple operating systems and applications to run in independent partitions. A partition behaves like a
virtual machine (VM) and provides isolation and protection across partitions. Each partition is allocated its
own subset of host physical memory.
3.3.21 JTAG Boundary-Scan
The Intel® C600-A chipset adds the industry standard JTAG interface and enables Boundary-Scan in
place of the XOR chains used in previous generations of chipsets. Boundary-Scan can be used to ensure
device connectivity during the board manufacturing process. The JTAG interface allows system
manufacturers to improve efficiency by using industry available tools to test the Intel® C600-A chipset on
an assembled board. Since JTAG is a serial interface, it eliminates the need to create probe points for
every pin in an XOR chain. This eases pin breakout and trace routing and simplifies the interface between
the system and a bed-of-nails tester.
3.3.22 KVM/Serial Over Lan (SOL) Function
These functions support redirection of keyboard, mouse, and text screen to a terminal window on a
remote console. The keyboard, mouse, and text redirection enables the control of the client machine
through the network. Text, mouse, and keyboard redirection allows the remote machine to control and
configure the client by entering BIOS setup. The KVM/SOL function emulates a standard PCI serial port
and redirects the data from the serial port to the management console using LAN. KVM has additional
requirements of internal graphics and SOL may be used when KVM is not supported.
3.3.23 On-board SAS/SATA Support and Options
The Intel® C600 chipset provides storage support by two integrated controllers: AHCI and SCU. By
default the server board will support up to 10 SATA ports: Two white 6Gb/sec SATA ports from the
AHCI controller labeled as “SATA_0” and SATA_1 and two MINISAS 3Gb/sec SATA/SAS ports
routed from the SCU controller labeled as “SCU0 (PORT0-3) and SCU1(PORT4-7).
The SCU Port can be configured with the two embedded software RAID options:
Intel® Embedded Server RAID Technology 2 (ESRT2) based on LSI* MegaRAID SW
RAID technology supporting RAID levels 0,1, and 10.
Intel® Rapid Storage Technology (RSTe) supporting RAID levels 0, 1, 5, and 10.
3.3.23.1 Intel®
Embedded Server RAID Technology 2 (ESRT2)
Features of the embedded software RAID option Intel® Embedded Server RAID Technology 2
(ESRT2) include the following:
Based on LSI* MegaRAID Software Stack
Software RAID with system providing memory and CPU utilization
Supported RAID Levels 0,1,5,10
4 and 8 Port SATA RAID 5 support provided with appropriate Intel® RAID C600
Upgrade Key
4 and 8 Port SAS RAID 5 support provided with appropriate Intel® RAID C600
Upgrade Key
Maximum drive support = 8
Open Source Compliance = Binary Driver (includes Partial Source files) or Open Source
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 39
using MDRAID layer in Linux.
OS Support = Windows 7*, Windows 2008*, Windows 2003*, RHEL*, SLES, other Linux*
variants using partial source builds.
Utilities = Windows* GUI and CLI, Linux GUI and CLI, DOS CLI, and EFI CLI
3.3.23.2 Intel®
Rapid Storage Technology (RSTe)
Features of the embedded software RAID option Intel® Rapid Storage Technology (RSTe)
include the following:
Software RAID with system providing memory and CPU utilization
Supported RAID Levels 0,1,5,10
o 4 Port SATA RAID 5 available standard (no option key required)
o 8 Port SATA RAID 5 support provided with appropriate Intel® RAID C600 Upgrade
Key
o No SAS RAID 5 support
Maximum drive support = 32 (in arrays with 8 port SAS), 16 (in arrays with 4 port SAS),
128 (JBOD)
Open Source Compliance = Yes (uses MDRAID)
OS Support = Windows 7*, Windows 2008*, Windows 2003*, RHEL* 6.2 and later,
SLES* 11 w/SP2 and later, VMWare* 5.x.
Utilities = Windows* GUI and CLI, Linux CLI, DOS CLI, and EFI CLI
Uses Matrix Storage Manager for Windows*
MDRAID supported in Linux* (does not require a driver)
Note: No boot drive support to targets attached through SAS expander card
3.4 PCI Subsystem
The primary I/O buses for the Intel® Server Board S2600IP and Intel® Workstation Board W2600CR are
PCI Express* Gen3 with six independent PCI bus segments. The following tables list the characteristics
of the PCI bus segments.
Table 8. Intel® Server Board S2600IP/Workstation Board W2600CR PCI Bus Segment
Characteristics
Voltage
Width
Speed
Type
PCI I/O Card Slots
3.3 V
x16
32 GB/S
PCI
Express*
Gen3
X16 PCI Express* Gen3 throughput
to Slot1 (x16 mechanically)
3.3 V
X8 or none
(with mux)
16 GB/S or
none
PCI
Express*
Gen3
x8 PCI Express* Gen3 throughput
to Slot 2 (x8 mechanically)
3.3 V
x16 or x8(with
mux)
32 GB/S or
16 GB/S
PCI
Express*
Gen3
x16 PCI Express* Gen3 throughput
to Slot 3 (x16 mechanically)
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
40 Intel order number G34153-003 Revision 1.2
3.3 V
X8 or none
(with mux)
16 GB/S or
none
PCI
Express*
Gen3
x8 PCI Express* Gen3 throughput
to Slot 4 (x8 mechanically, Non-
Persistent)
3.3 V
x16 or x8(with
mux)
32 GB/S or
16 GB/S
PCI
Express*
Gen3
X16 PCI Express* Gen3 throughput
to Slot 5 (x16 mechanically, Non-
Persistent)
3.3 V
X8 or none
(with mux)
16 GB/S or
none
PCI
Express*
Gen3
x8 PCI Express* Gen3 throughput
to Slot 6 (x8 mechanically, Non-
Persistent)
3.3 V
x16 or x8(with
mux)
32 GB/S or
16 GB/S
PCI
Express*
Gen3
X16 PCI Express* Gen3 throughput
to Slot 7 (x16 mechanically, Non-
Persistent)
3.3 V
X4
4 GB/S
PCI
Express*
Gen2
X4 PCI Express* Gen2 throughput
to Slot 8 (x8 mechanically, Non-
Persistent)
3.5 Network Interface Controller
The Intel® Server Board S2600IP and Workstation Board S2600CR has a Intel® Ethernet Controller I350
GbE Controller. The controller supports PCI Express* PCIe v2.0 (5GT/s and 2.5GT/s). The controller
enables four-port or two-port 1000BASE-T implementations using integrated PHY’s. The controller
supports VMDq, SR-IOV, EEE, and DMA Coalescing.
3.5.1 Network Interface
Network connectivity is provided by means of an onboard Intel® Ethernet Controller 1350-AM4 providing
up to four 10/100/1000 Mb Ethernet ports.
On the Intel® Server Board S2600IP, four external 10/100/1000 Mb RJ45 Ethernet ports are provided. On
the Intel® Workstation Board W2600CR, two external 10/100/1000 Mb RJ45 Ethernet ports are provided.
Each Ethernet port drives two LEDs located on each network interface connector. The LED at the right of
the connector is the link/activity LED and indicates network connection when on, and transmit/receive
activity when blinking. The LED at the left of the connector indicates link speed as defined in the following
table.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 41
LED Color
LED State
NIC State
Green/Amber (Right)
Off
10 Mbps
Amber
100 Mbps
Green
1000 Mbps
Green (Left)
On
Active Connection
Blinking
Transmit/Receive activity
Figure 20. External RJ45 NIC Port LED Definition
3.6 I/O Module Support (not avaiable for Intel® Server Board S2600IP4L and
Intel® Workstation Board W2600CR2L)
To broaden the standard on-board feature set, the server board supports the option of adding a single I/O
module providing external ports for a variety of networking interfaces. The I/O module attaches to a high
density 80-pin connector on the server board labeled “IO_Module”.
Supported I/O modules include:
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
42 Intel order number G34153-003 Revision 1.2
Product Code and iPN
Description
AXX10GBNIAIOM
MM# 917905
Dual SFP+ port 10GbE IO Module based on Intel® 82599 10GbE Ethernet Controller
AXX10GBTWLIOM
MM# 917907
Dual RJ45 Port, 10GBASE-T IO Module, based on Intel® I350 Ethernet chipset
AXX1FDRIBIOM
MM# 918607
Single Port, FDR speed Infiniband* module, with QSFP connector.
AXX4P1GBPWLIOM
MM# 917911
Quad Port 1GbE 1o Module based on Intel® Ethernet Controller I350
AXXIOMKIT
MM# 920852
I/O Module Cable and Brackets
Figure 21. Supported I/O Module Options
Notes:
1. I/O Module cable and Brackets accessory is necessary to support I/O module on Intel® Server Board
S2600IP.
2. IOM connector only supports PCIe Gen1 Speed
3.7 SAS ROC Module Support
The system provides support for Intel® Integrated RAID mezzanine modules that utilize a high
density 80-pin connector (labeled “SAS_MOD”) on the server board.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 43
Features of this option include:
Does not utilize a PCIe slot
SKU options to support full or entry level hardware RAID
4 or 8 port and SAS/SATA or SATA only ROC options
SKU options to support 512MB or 1GB embedded memory
Intel designed flash + optional support for super-cap backup (Maintenance Free Back Up) or
improved Lithium Polymer battery
Table 9. Supported Intel® Integrated RAID Modules
External Name
Description
Product Code
Intel® Integrated RAID Module
RMS25CB080
8 Port SAS-2.1, Full HW RAID, 1GB, Mezz Slot
RAID Levels 0,1,10, 5, 50, 6, 60
RMS25CB080
Intel® Integrated RAID Module
RMS25CB040
4 Port SAS-2.1, Full HW RAID, 1GB, Mezz Slot
RAID Levels 0,1,10, 5, 50, 6, 60
RMS25CB040
Intel® Integrated RAID Module
RMT3CB080
8 Port SATA-3, Full HW RAID, 512MB, Mezz
Slot
RAID Levels 0,1,10, 5, 50, 6, 60
RMT3CB080
Intel® Integrated RAID Module
RMS25KB080
8 Port SAS-2.1, Entry-level HW RAID, Mezz Slot
RAID Levels 0,1,1E
RMS25KB080
Intel® Integrated RAID Module
RMS25KB040
4 Port SAS-2.1, Entry-level HW RAID, Mezz Slot
RAID Levels 0,1,1E
RMS25KB040
For additional product information, please refer the following Intel® document:
Intel® Integrated RAID Module RMS25PB080, RMS25PB040, RMS25CB080, and
RMS25CB040 Hardware User’s Guide – Intel Order Number G37519-003.
3.8 HD Audio Support (Intel® Workstation Board W2600CR Only)
The Intel® Workstation Board W2600CR support 7.1 HD Audio through the High Definition Audio Codec
Realtek* ALC889. The ALC889 provides ten DAC channels that simultaneously support 7.1 sound
playback, plus two channels of independent stereo sound output (multiple streaming) through the front
panel stereo outputs. Also supports two channels of S/PDIF In/Out (W2600CR only supports 1 S/PDIF
Out port) and two channels of Microphone In (Front/Rear). The ALC889 is driven by the Intel® HD Audio
Interface (Azalia) from Intel® C600-A chipset.
Functional Architecture Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
44 Intel order number G34153-003 Revision 1.2
Table 10. Standard Speaker Channels
Channel name
Identifier
1.0
Mono
2.0
Stereo
5.1
Surround
7.1
Surround
Front Left
SPEAKER_FRONT_LEFT
No
Yes
Yes
Yes
Front Right
SPEAKER_FRONT_RIGHT
No
Yes
Yes
Yes
Front Center
SPEAKER_FRONT_CENTER
Yes
No
Yes
Yes
Low Frequency (Subwoofer)
SPEAKER_LOW_FREQUENCY
No
No
Yes
Yes
Back Left
SPEAKER_BACK_LEFT
No
No
Yes
Yes
Back Right
SPEAKER_BACK_RIGHT
No
No
Yes
Yes
Side Left
SPEAKER_SIDE_LEFT
No
No
No
Yes
Side Right
SPEAKER_SIDE_RIGHT
No
No
No
Yes
3.9 USB3.0 Support (Intel® Workstation Board W2600CR Only)
The Intel® Workstation Board W2600CR supports two USB3.0 SuperSpeed* ports, which is required as a
standard Workstation feature. The TI 2 port USB3.0 discrete host controller TUSB7320 is used to meet
this requirement. The TUSB7320 USB3.0 host controller complies with Universal Serial Bus 3.0
Specification and Intel’s eXtensible Host Controller Interface (xHCI).
Figure 22. USB3.0 Discrete Host Controller Block Diagram
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Functional Architecture
Revision 1.2 Intel order number G34153-003 45
3.10 IEEE1394b Support (Intel® Workstation Board W2600CR Only)
Intel® Workstation Board W2600CR offers one front panel IEEE 1394b port from a discrete controller
(Texas Instruments XIO2221).The XIO2221 uses a PCIe x1 Gen 1 upstream interface from Intel® C600-A
chipset. When connected to 1394b compliant devices, the XIO2221 can transfer data at speeds of up to
800 Mbps. The Intel® Workstation Board W2600CR includes an internal 1394b connector that allows for a
front panel 1394b cable attach.
Figure 23. IEEE 1394b Discrete Host Controller Block Diagram
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
46 Intel order number G34153-003 Revision 1.2
4. Platform Management Overview
4.1 Server Management Function Architecture
4.1.1 Feature Support
4.1.1.1 IPMI 2.0 Features
The IPMI 2.0 features are as follows:
1. Baseboard management controller (BMC)
2. IPMI Watchdog timer
3. Messaging support, including command bridging and user/session support
4. Chassis device functionality, including power/reset control and BIOS boot flags support
5. Event receiver device: The BMC receives and processes events from other platform subsystems.
6. Field Replaceable Unit (FRU) inventory device functionality: The BMC supports access to system
FRU devices using IPMI FRU commands.
7. System Event Log (SEL) device functionality: The BMC supports and provides access to a SEL.
8. Sensor Data Record (SDR) repository device functionality: The BMC supports storage and access of
system SDRs.
9. Sensor device and sensor scanning/monitoring: The BMC provides IPMI management of sensors. It
polls sensors to monitor and report system health.
10. IPMI interfaces
11. Host interfaces include system management software (SMS) with receive message queue support,
and server management mode (SMM)
12. IPMB interface
13. LAN interface that supports the IPMI-over-LAN protocol Remote Management Control Protocol
(RMCP, RMCP+)
14. Serial-over-LAN (SOL)
15. ACPI state synchronization: The BMC tracks ACPI state changes that are provided by the BIOS.
16. BMC self test: The BMC performs initialization and run-time self-tests and makes results available to
external entities.
See also the Intelligent Platform Management Interface Specification Second Generation, Version 2.0.
4.1.1.2 Non IPMI features
The BMC supports the following non-IPMI features. This list does not preclude support for future
enhancements or additions.
In-circuit BMC firmware update
Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality.
Chassis intrusion detection (dependent on platform support)
Basic fan control using Control version 2 SDRs
Fan redundancy monitoring and support
Power supply redundancy monitoring and support
Hot-swap fan support
Acoustic management: Support for multiple fan profiles
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 47
Signal testing support: The BMC provides test commands for setting and getting platform signal
states.
The BMC generates diagnostic beep codes for fault conditions.
System GUID storage and retrieval
Front panel management: The BMC controls the system status LED and chassis ID LED. It
supports secure lockout of certain front panel functionality and monitors button presses. The
chassis ID LED is turned on using a front panel button or a command.
Power state retention
Power fault analysis
Intel® Light-Guided Diagnostics
Power unit management: Support for power unit sensor. The BMC handles power-good
dropout conditions.
DIMM temperature monitoring: New sensors and improved acoustic management using closed-
loop fan control algorithm taking into account DIMM temperature readings.
Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported on
embedded NICs).
Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported on
embedded NICs).
Platform environment control interface (PECI) thermal management support
E-mail alerting
Embedded web server
Integrated KVM.
Integrated Remote Media Redirection
Lightweight Directory Access Protocol (LDAP) support
Intel® Intelligent Power Node Manager support
4.1.1.3 New Manageability Features
Intel® S1400/S1600/S2400/S2600 Server Platforms offer a number of changes and additions to the
manageability features that are supported on the previous generation of servers. The following is a list of
the more significant changes that are common to this generation Integrated BMC based Intel® Server
boards:
Sensor and SEL logging additions/enhancements (for example, additional thermal monitoring
capability)
SEL Severity Tracking and the Extended SEL
Embedded platform debug feature which allows capture of detailed data for later analysis.
Provisioning and inventory enhancements:
o Inventory data/system information export (partial SMBIOS table)
Enhancements to fan speed control.
DCMI 1.1 compliance (product-specific).
Support for embedded web server UI in Basic Manageability feature set.
Enhancements to embedded web server
o Human-readable SEL
o Additional system configurability
o Additional system monitoring capability
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
48 Intel order number G34153-003 Revision 1.2
o Enhanced on-line help
Enhancements to KVM redirection
o Support for higher resolution
Support for EU Lot6 compliance
Management support for PMBus* rev1.2 compliant power supplies
BMC Data Repository (Managed Data Region Feature)
Local Control Display Panel
System Airflow Monitoring
Exit Air Temperature Monitoring
Ethernet Controller Thermal Monitoring
Global Aggregate Temperature Margin Sensor
Memory Thermal Management
Power Supply Fan Sensors
Energy Star Server Support
Smart Ride Through (SmaRT)/ Closed Loop System Throttling (CLST)
Power Supply Cold Redundancy
Power Supply FW Update
Power Supply Compatibility Check
BMC FW reliability enhancements:
o Redundant BMC boot blocks to avoid possibility of a corrupted boot block resulting
in a scenario that prevents a user from updating the BMC.
o BMC System Management Health Monitoring
4.1.2 Basic and Advanced Features
The bellowing table lists basic and advanced feature support. Individual features may vary by platform.
See the appropriate Platform Specific EPS addendum for more information.
Table 11. Basic and Advanced Features
Feature
Basic
Advanced
IPMI 2.0 Feature Support
X
X
In-circuit BMC Firmware Update
X
X
FRB 2
X
X
Chassis Intrusion Detection
X
X
Fan Redundancy Monitoring
X
X
Hot-Swap Fan Support
X
X
Acoustic Management
X
X
Diagnostic Beep Code Support
X
X
Power State Retention
X
X
ARP/DHCP Support
X
X
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 49
Feature
Basic
Advanced
PECI Thermal Management Support
X
X
E-mail Alerting
X
X
Embedded Web Server
X
X
SSH Support
X
X
Integrated KVM
X
Integrated Remote Media Redirection
X
Lightweight Directory Access Protocol (LDAP)
X
X
Intel® Intelligent Power Node Manager Support
X
X
SMASH CLP
X
X
4.1.3 Integrated BMC Hardware: Emulex* Pilot III
4.1.3.1 Emulex* Pilot III Baseboard Management Controller Functionality
The Integrated BMC is provided by an embedded ARM9 controller and associated peripheral functionality
that is required for IPMI-based server management. Firmware usage of these hardware features is
platform dependent.
The following is a summary of the Integrated BMC management hardware features that comprise the
BMC:
400MHz 32-bit ARM9 processor with memory management unit (MMU)
Two independent10/100/1000 Ethernet Controllers with Reduced Media Independent Interface
(RMII)/ Reduced Gigabit Media Independent Interface (RGMII) support
DDR2/3 16-bit interface with up to 800 MHz operation
16 10-bit ADCs
Sixteen fan tachometers
Eight Pulse Width Modulators (PWM)
Chassis intrusion logic
JTAG Master
Eight I2C interfaces with master-slave and SMBus* timeout support. All interfaces are SMBus* 2.0
compliant.
Parallel general-purpose I/O Ports (16 direct, 32 shared)
Serial general-purpose I/O Ports (80 in and 80 out)
Three UARTs
Platform Environmental Control Interface (PECI)
Six general-purpose timers
Interrupt controller
Multiple Serial Peripheral Interface (SPI) flash interfaces
NAND/Memory interface
Sixteen mailbox registers for communication between the BMC and host
LPC ROM interface
BMC watchdog timer capability
SD/MMC card controller with DMA support
LED support with programmable blink rate controls on GPIOs
Port 80h snooping capability
Secondary Service Processor (SSP), which provides the HW capability of offloading time critical
processing tasks from the main ARM core.
Emulex* Pilot III contains an integrated SIO, KVMS subsystem and graphics controller with the following
features:
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
50 Intel order number G34153-003 Revision 1.2
4.1.3.1.1 Super I/O (SIO)
The BMC integrates a super I/O module with the following features:
Keyboard Style/BT interface for BMC support
Two Fully Functional Serial Ports, compatible with the 16C550
Serial IRQ Support
Up to 16 Shared GPIO available for host processor
Programmable Wake-up Event Support
Plug and Play Register Set
Power Supply Control
4.1.3.1.2 Graphics Controller
The graphics controller provides the following features:
Integrated Graphics Core with 2D Hardware accelerator
High speed Integrated 24-bit RAMDAC
DDR-2/3 memory interface with 16Mbytes of memory allocated and reported for graphics memory.
4.1.3.1.3 Remote Keyboard, Video, Mouse, and Storage (KVMS )
The Integrated BMC contains a remote KVMS subsystem with the following features:
USB 2.0 interface for Keyboard, Mouse and Remote storage such as CD/DVD ROM and floppy
USB 1.1/USB 2.0 interface for PS2 to USB bridging, remote Keyboard and Mouse
Hardware Based Video Compression and Redirection Logic
Supports both text and Graphics redirection
Hardware assisted Video redirection using the Frame Processing Engine
Direct interface to the Integrated Graphics Controller registers and Frame buffer
Hardware-based encryption engine
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 51
Figure 24. Integrated BMC Hardware
4.2 Server Management Functional Specifications
4.2.1 BMC Internal Timestamp Clock
The BMC maintains an internal timestamp clock that is used by various BMC subsystems, for example,
time stamping SEL entries. As part of BMC initialization after AC power is applied or the BMC is reset, the
BMC initializes this internal clock to the value retrieved from the SSB component’s RTC from a SMBus*
slave read operation. This is the system RTC and is on the battery power well so it maintains the current
time even when there is no AC supplied to the system.
4.2.1.1 System Clock Synchronization
The BIOS must send the Set SEL Time command with the current system time to the BMC during
system Power-on Self Test (POST). Synchronization during very early POST is preferred, so that any
SEL entries recorded during system boot can be accurately time stamped. Additionally, during sleep state
transitions other than S0 the BIOS will synchronize the time.
If the time is modified through an OS interface, then the BMC’s time is not synchronized until the next
system reboot.
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
52 Intel order number G34153-003 Revision 1.2
4.2.2 System Event Log (SEL)
The BMC implements the system event log as specified in the Intelligent Platform Management Interface
Specification, Version 2.0. The SEL is accessible regardless of the system power state through the
BMC's in-band and out-of-band interfaces.
The BMC allocates 95231 bytes (approximately 93 KB) of non-volatile storage space to store system
events. The SEL timestamps may not be in order. Up to 3,639 SEL records can be stored at a time. Any
command that results in an overflow of the SEL beyond the allocated space is rejected with an “Out of
Space” IPMI completion code (C4h).
4.2.3 Sensor Data Record (SDR) Repository
The BMC implements the sensor data record (SDR) repository as specified in the Intelligent Platform
Management Interface Specification, Version 2.0. The SDR is accessible through the BMC’s in-band and
out-of-band interfaces regardless of the system power state The BMC allocates 65,519 bytes of non-
volatile storage space for the SDR.
4.2.4 Field Replaceable Unit (FRU) Inventory Device
The BMC implements the interface for logical FRU inventory devices as specified in the Intelligent
Platform Management Interface Specification, Version 2.0. This functionality provides commands used for
accessing and managing the FRU inventory information. These commands can be delivered through all
interfaces.
The BMC provides FRU device command access to its own FRU device and to the FRU devices
throughout the server. The FRU device ID mapping is defined in the Platform Specific Information. The
BMC controls the mapping of the FRU device ID to the physical device.
4.2.5 BMC Beep Codes
The BMC may generate beep codes upon detection of failure conditions. Beep codes are
sounded each time the problem is discovered (for example, on each power-up attempt), but are
not sounded continuously. Common supported codes are listed in below Table
Additional platform-specific beep codes can be found in the appropriate Platform Specific
Information. Each digit in the code is represented by a sequence of beeps whose count is equal
to the digit.
Table 12. BMC Beep Codes
Code
Reason for Beep
Associated Sensors
1-5-2-1
No CPUs installed or first CPU socket is
empty.
CPU Missing Sensor
1-5-2-4
MSID Mismatch.
MSID Mismatch Sensor.
1-5-4-2
Power fault: DC power is unexpectedly
lost (power good dropout).
Power unit power unit failure
offset.
1-5-4-4
Power control fault (power good assertion
timeout).
Power unit soft power control
failure offset.
1-5-1-2
VR Watchdog Timer sensor assertion
VR Watchdog Timer
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 53
Code
Reason for Beep
Associated Sensors
1-5-1-4
The system does not power on or
unexpectedly powers off and a power
supply unit (PSU) is present that is an
incompatible model with one or more
other PSUs in the system
PS Status
4.2.6 Diagnostic Interrupt (NMI) Button
The BMC generates an NMI pulse under certain conditions. The BMC-generated NMI pulse duration is at
least 30 ms. Once an NMI has been generated by the BMC, the BMC does not generate another NMI
until the system has been reset or powered down.
The following actions cause the BMC to generate an NMI pulse:
1. Receiving a Chassis Control command to pulse the diagnostic interrupt. This command does not
cause an event to be logged in the SEL.
2. Watchdog timer pre-timeout expiration with NMI/diagnostic interrupt pre-timeout action enabled.
The following table shows the behavior regarding NMI signal generation and event logging by the
BMC.
Table 13. NMI Signal Generation and Event Logging
Causal Event
NMI
Signal Generation
Front Panel Diag Interrupt Sensor Event Logging
Support
Chassis Control command (pulse diagnostic
interrupt)
X
Front panel diagnostic interrupt button pressed
X
X
Watchdog Timer pre-timeout expiration with
NMI/diagnostic interrupt action
X
X
4.2.7 BMC Watchdog
The BMC FW is increasingly called upon to perform system functions that are time-critical in that failure to
provide these functions in a timely manner can result in system or component damage. Intel®
S1400/S1600/S2400/S2600 Server Platforms introduce a BMC watchdog feature to provide a safe-guard
against this scenario by providing an automatic recovery mechanism. It also can provide automatic
recovery of functionality that has failed due to a fatal FW defect triggered by a rare sequence of events or
a BMC hang due to some type of HW glitch (for example, power).
This feature is comprised of a set of capabilities whose purpose is to detect misbehaving subsections of
BMC firmware, the BMC CPU itself, or HW subsystems of the BMC component, and to take appropriate
action to restore proper operation. The action taken is dependent on the nature of the detected failure and
may result in a restart of the BMC CPU, one or more BMC HW subsystems, or a restart of malfunctioning
FW subsystems.
The BMC watchdog feature will only allow up to three resets of the BMC CPU (such as HW
reset) or entire FW stack (such as a SW reset) before giving up and remaining in the uBOOT
code. This count is cleared upon cycling of power to the BMC or upon continuous operation of
the BMC without a watchdog-generated reset occurring for a period of > 30 minutes. The BMC
FW logs a SEL event indicating that a watchdog-generated BMC reset (either soft or hard reset)
has occurred. This event may be logged after the actual reset has occurred. Refer sensor
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
54 Intel order number G34153-003 Revision 1.2
section for details for the related sensor definition. The BMC will also indicate a degraded
system status on the Front Panel Status LED after an BMC HW reset or FW stack reset. This
state (which follows the state of the associated sensor) will be cleared upon system reset or (AC
or DC) power cycle.
Note: A reset of the BMC may result in the following system degradations that will require a
system reset or power cycle to correct:
1. Timeout value for the rotation period can be set using this parameter; potentially incorrect
ACPI Power State reported by the BMC.
2. Reversion of temporary test modes for the BMC (for example, as set through Set SM Signal
command) back to normal operational modes.
3. FP status LED and DIMM fault LEDs may not reflect BIOS detected errors.
4.3 Sensor Monitoring
4.3.1 Overview
The BMC monitors system hardware and reports system health. The information gathered from physical
sensors is translated into IPMI sensors as part of the “IPMI Sensor Model”. The BMC also reports various
system state changes by maintaining virtual sensors that are not specifically tied to physical hardware.
This section describes the BMC sensors as well as describing how specific sensor types are modeled.
Unless otherwise specified, the term “sensor” refers to the IPMI sensor-model definition of a sensor.
4.3.2 Core Sensor List for EPSD Platforms Based on Intel®
Xeon®
Processor E5
4600/2600/2400/1600/1400 Product Families
Specific server boards may only implement a sub-set of sensors and/or may include additional sensors.
The system-specific details of supported sensors and events are described in the Appendix of this
document. The actual sensor name associated with a sensor number may vary between server boards or
systems.
Sensor Type Codes
Sensor table given below lists the sensor identification numbers and information regarding the sensor
type, name, supported thresholds, assertion and de-assertion information, and a brief description of the
sensor purpose. Refer to the Intelligent Platform Management Interface Specification, Version 2.0 for
sensor and event/reading-type table information.
Sensor Type
The sensor type references the values in the Sensor Type Codes table in the Intelligent Platform
Management Interface Specification Second Generation v2.0. It provides a context to interpret
the sensor.
Event/Reading Type
The event/reading type references values from the Event/Reading Type Code Ranges and the
Generic Event/Reading Type Code tables in the Intelligent Platform Management Interface
Specification Second Generation v2.0. Digital sensors are specific type of discrete sensors that
only have two states.
Event Thresholds/Triggers
The following event thresholds are supported for threshold type sensors:
- [u,l][nr,c,nc] upper non-recoverable, upper critical, upper non-critical, lower
non-recoverable, lower critical, lower non-critical uc, lc upper critical, lower critical
Event triggers are supported event-generating offsets for discrete type sensors. The offsets can
be found in the Generic Event/Reading Type Code or Sensor Type Code tables in the Intelligent
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 55
Platform Management Interface Specification Second Generation, Version 2.0, depending on
whether the sensor event/reading type is generic or a sensor-specific response.
Assertion/Deassertion
Assertion and de-assertion indicators reveal the type of events this sensor generates:
- As: Assertion
- De: De-assertion
Readable Value/Offsets
- Readable value indicates the type of value returned for threshold and other non-
discrete type sensors.
- Readable offsets indicate the offsets for discrete sensors that are readable by means
of the Get Sensor Reading command. Unless otherwise indicated, event triggers are
readable. Readable offsets consist of the reading type offsets that do not generate
events.
Event Data
Event data is the data that is included in an event message generated by the associated sensor.
For threshold-based sensors, these abbreviations are used:
- R: Reading value
- T: Threshold value
Rearm Sensors
The rearm is a request for the event status for a sensor to be rechecked and updated upon a
transition between good and bad states. Rearming the sensors can be done manually or
automatically. This column indicates the type supported by the sensor. The following
abbreviations are used in the comment column to describe a sensor:
- A: Auto-rearm
- M: Manual rearm
- I: Rearm by init agent
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the count of
hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the front panel status LED.
Standby
Some sensors operate on standby power. These sensors may be accessed and/or generate
events when the main (system) power is off, but AC power is present.
4.3.3 BMC System Management Health Monitoring
The BMC tracks the health of each of its IPMI sensors and report failures by providing a “BMC FW
Health” sensor of the IPMI 2.0 sensor type Management Subsystem Health with support for the Sensor
Failure offset. Only assertions should be logged into the SEL for the Sensor Failure offset. The sensor
number of the failed sensor is provided in event data byte 2, as per the IPMI 2.0 Specification. The BMC
Firmware Health sensor asserts for any sensor when 10 consecutive sensor errors are read. These are
not standard sensor events (that is, threshold crossings or discrete assertions). These are BMC Hardware
Access Layer (HAL) errors like I2C NAKs or internal errors while attempting to read a register. If a
successful sensor read is completed, the counter resets to zero.
IPMI Sensor Characteristics
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
56 Intel order number G34153-003 Revision 1.2
1. Event reading type code: 6Fh (Sensor specific)
2. Sensor type code: 28h (Management Subsystem Health)
3. Rearm type: Auto
If this sensor is implemented, then the following sensor-specific offsets are supported.
Table 14. Supported BMC FW Health Sensor Offsets
Offset
Description
Event Logging
04h
Sensor failure
Assertion and deassertion
4.3.4 Processor Sensors
The BMC provides IPMI sensors for processors and associated components, such as voltage regulators
and fans. The sensors are implemented on a per-processor basis.
Table 15. Processor Sensors
Sensor Name
Per-Processor
Socket
Description
Processor Status
Yes
Processor presence and fault state
Digital Thermal Sensor
Yes
Relative temperature reading by means of PECI
Processor VRD Over-Temperature
Indication
Yes
Discrete sensor that indicates a processor VRD has
crossed an upper operating temperature threshold
Processor Voltage
Yes
Threshold sensor that indicates a processor power-good
state
Processor Thermal Control (Prochot)
Yes
Percentage of time a processor is throttling due to
thermal conditions
4.3.4.1 Processor Status Sensors
The BMC provides an IPMI sensor of type processor for monitoring status information for each processor
slot. If an event state (sensor offset) has been asserted, it remains asserted until one of the following
happens:
1. A Rearm Sensor Events command is executed for the processor status sensor.
2. AC or DC power cycle, system reset, or system boot occurs.
The BMC provides system status indication to the front panel LEDs for processor fault conditions shown
in Table 16.
CPU Presence status is not saved across AC power cycles and therefore will not generate a de-assertion
after cycling AC power.
Table 16. Processor Status Sensor Implementation
Offset
Processor Status
Detected By
0
Internal error (IERR)
Not Supported
1
Thermal trip
BMC
2
FRB1/BIST failure
Not Supported
3
FRB2/Hang in POST failure
BIOS1
4
FRB3/Processor startup/initialization failure (CPU fails to start)
Not Supported
5
Configuration error (for DMI)
BIOS1
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 57
Offset
Processor Status
Detected By
6
SM BIOS uncorrectable CPU-complex error
Not Supported
7
Processor presence detected
BMC
8
Processor disabled
Not Supported
9
Terminator presence detected
Not Supported
Note: Fault is not reflected in the processor status sensor.
4.3.4.1.1 Processor Presence
Upon BMC initialization, which occurs when AC power is applied or the BMC is reset, the processor
presence offset is initialized to the deasserted state and then the BMC checks to see if the processor is
present and sets the presence offset accordingly.
This state is updated at each DC power-on and at system resets. The net effect of this is that there
should be one event logged at BMC startup for processor presence for each installed processor,
assuming the SDR is configured to generate the event. No additional events for processor presence are
expected unless the sensor is manually re-armed using an IPMI command or a processor is removed or
inserted. Note that removal and insertion should only occur when AC power is removed from the system
so it is not expected that a SEL entry will be seen for this specific occurrence.
4.3.4.2 Processor Population Fault (CPU Missing) Sensor
The BMC supports a Processor Population Fault sensor for monitoring for the condition in which
processor slots are not populated as required by the platform HW to allow power-on of the
system.
At BMC startup, the BMC will check for the fault condition and set the sensor state accordingly.
The BMC also checks for this fault condition at each attempt to DC power-on the system. At
each DC power-on attempt, a beep code is generated if this fault is detected. Please refer Table
9 (BMC Beep Codes) for beep code details.
The following steps are used to correct the fault condition and clear the sensor state:
1. AC power down the server.
2. Install the missing processor into the correct slot.
3. AC power on the server.
Refer to the applicable platform BMC EPS as to the details of what population rules must be
followed.
4.3.4.3 ERR2 Timeout Monitoring
The BMC supports an ERR2 Timeout Sensor (1 per CPU) that asserts if a CPU’s ERR2 signal has been
asserted for longer than a fixed time period (> 90 seconds). ERR[2] is a processor signal that indicates
when the IIO (Integrated IO module in the processor) has a fatal error which could not be communicated
to the core to trigger SMI. ERR[2] events are fatal error conditions, where the BIOS and OS will attempt to
gracefully handle error, but may not be always do so reliably. A continuously asserted ERR2 signal is an
indication that the BIOS cannot service the condition that caused the error. This is usually because that
condition prevents the BIOS from running.
When an ERR2 timeout occurs, the BMC asserts/deasserts the ERR2 Timeout Sensor, and logs a SEL
event for that sensor. The default behavior for BMC core firmware is to initiate a system reset upon
detection of an ERR2 timeout. The BIOS setup utility provides an option to disable or enable system reset
by the BMC for detection of this condition.
IPMI Sensor Characteristics
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
58 Intel order number G34153-003 Revision 1.2
1. Event reading type code: 03h (Generic digital discrete)
2. Sensor type code: 07h (Processor)
3. Rearm type: Auto
Table 17. Supported ERR2 Timeout Sensor Offsets
Offset
Description
Event Logging
01h
State asserted
Assertion and deassertion
4.3.4.4 CATERR Sensor and Market Segment ID (MSID) Mismatch
The BMC supports a CATERR sensor for monitoring the system CATERR signal.
The CATERR signal is defined as having 3 states; high (no event), pulsed low (possibly fatal may be able
to recover), and low (fatal). All processors in a system have their CATERR pins tied together. The pin is
used as a communication path to signal a catastrophic system event to all CPUs. The BMC has direct
access to this aggregate CATERR signal.
The BMC only monitors for the “CATERR held low” condition. A pulsed low condition is ignored by the
BMC.
If a CATERR-low condition is detected, the BMC logs an error message to the SEL against the
CATERR sensor and then queries each CPU to determine if it was due to an MSID mismatch
condition. An MSID mismatch occurs if a processor is installed into a system board that has
incompatible power capabilities. The MSID mismatch condition is indicated in a processor
machine check MSR. If PECI is non-functional (it isn’t guaranteed in this situation), then MSID
mismatch can’t be detected in that case.
If the CATERR is due to an MSID mismatch, then the BMC will log an additional SEL log
against the MSID Mismatch sensor, light the CPU fault LED, emit a beep code, and let the
system hang. Please refer Table 9 (BMC Beep Codes) for beep code details. If no MSID
mismatch is detected, then the default action after logging the SEL entry is to reset the system.
The BIOS setup utility provides an option to disable or enable system reset by the BMC for
detection of this condition.
4.3.4.5 CATERR Sensor
The BMC supports a CATERR sensor for monitoring the system CATERR signal.
The sensor is rearmed on power-on (AC or DC power on transitions). It is not rearmed on system resets
in order to avoid multiple SEL events that could occur due to a potential reset loop if the CATERR keeps
recurring, which would be the case if the CATERR was due to an MSID mismatch condition.
On EPSD boards, the CATERR signal from each CPU are tied together and routed to the BMC as one
signal. When the BMC detects that this aggregate CATERR signal has asserted, it can then go through
PECI to query each CPU to determine which one was the source of the error and write an OEM code
identifying the CPU slot into an event data byte in the SEL entry. If PECI is non-functional (it isn’t
guaranteed in this situation), then the OEM code should indicate that the source is unknown.
Event data byte 2 and byte 3 for CATERR sensor SEL events
ED2 - CATERR type.
0: Unknown
1: CATERR
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 59
2: CPU Core Error (not supported on EPSD Platforms Based on Intel® Xeon® Processor E5
4600/2600/2400/1600 Product Families)
3: MSID Mismatch
ED3 - CPU bitmap that causes the system CATERR.
[0]: CPU0
[1]: CPU1
[2]: CPU2
[3]: CPU3
IPMI Sensor Characteristics
1. Event reading type code: 03h (Digital discrete)
2. Sensor type code: 07h (Processor)
3. Rearm type: Manual
The following sensor-specific offsets are supported:
Table 18. Supported CATERR Sensor Offsets
Offset
Description
Event Logging
01h
State asserted
Assertion and deassertion
4.3.4.6 MSID Mismatch Sensor
The BMC supports a MSID Mismatch sensor for monitoring for the fault condition that will occur if there is
a power rating incompatibility between a baseboard and an a processor
The sensor is rearmed on power-on (AC or DC power on transitions).
IPMI Sensor Characteristics
1. Event reading type code: 03h (Digital discrete)
2. Sensor type code: 07h (Processor)
3. Rearm type: Manual
The following sensor-specific offsets are supported:
Table 19. Support MSID Mismatch Sensor Offsets
Offset
Description
Event Logging
01h
State asserted
Assertion and deassertion
4.4 Thermal and Acoustic Management
The Intel® Server Board S2600IP and Intel® Workstation Board W2600CR offers multiple thermal and
acoustic management features to maintain comprehensive thermal protection as well as intelligent fan
speed control. The features can be adjusted in BIOS interface with path BIOS > Advanced > System
Acoustic and Performance Configuration.
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
60 Intel order number G34153-003 Revision 1.2
4.4.1 Set Throttling Mode
Select the most appropriate memory thermal throttling mechanism for memory sub-system from
[Auto], [DCLTT], [SCLTT] and [SOLTT].
[Auto] BIOS automatically detect and identify the appropriate thermal throttling mechanism
based on DIMM type, airflow input, DIMM sensor availability.
[DCLTT] Dynamic Closed Loop Thermal Throttling: for the SOD DIMM with system airflow
input
[SCLTT] Static Close Loop Thermal Throttling: for the SOD DIMM without system airflow
input
[SOLTT] Static Open Loop Thermal Throttling: for the DIMMs without sensor on dimm (SOD)
The default setting is [Auto].
4.4.2 Altitude
Select the proper altitude that the system is distributed from [300m or less], [301m-900m], [901m-1500m],
[Above 1500m] options. Lower altitude selection can lead to potential thermal risk. And higher altitude
selection provides better cooling but with undesired acoustic and fan power consumption. If the altitude is
known, higher altitude is recommended in order to provide sufficient cooling. The default setting is [301m
900m].
4.4.3 Set Fan Profile
[Performance] and [Acoustic] fan profiles are available to select. The Acoustic mode offers best acoustic
experience and appropriate cooling capability covering mainstream and majority of the add-in cards.
Performance mode is designed to provide sufficient cooling capability covering all kinds of add-in cards
on the market. The default setting is [Performance]
4.4.4 Fan PWM Offset
This feature is reserved for manual adjustment to the minimum fan speed curves. The valid
range is from [0 to 100] which stands for 0% to 100% PWM adding to the minimum fan speed.
This feature is valid when Quiet Fan Idle Mode is at Enabled state. The default setting is [0].
4.4.5 Quiet Fan Idle Mode
This feature can be [Enabled] or [Disabled]. If enabled, the fan will either stopped or shift to a
lower speed when the aggregate sensor temperatures are satisfied indicating the system is at
ideal thermal/light loading conditions. When the aggregate sensor temperatures not satisfied,
the fan will shift back to normal control curves. If disabled, the fan will never stopped or shift into
lower fan speed whatever the aggregate sensor temperatures are satisfied or not. The default
setting is [Disabled]
Note:
1. The above features may or may not be in effective depends on the actual thermal
characters of a specific system.
2. Refer to System TPS for the board in Intel chassis thermal and acoustic management
3. Refer to Fan Control Whitepaper for the board in third party chassis fan speed control
customization.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 61
4.4.6 Thermal Sensor Input for Fan Speed Control
The BMC uses various IPMI sensors as inputs to FSC. Some of the sensors are actual
physical sensor and some are virtual sensors derived from calculation.
The following IPMI thermal sensors are used as input to the fan speed control:
Front Panel Temperature Sensor1
Baseboard Temperature Sensor2
CPU Margin Sensors3,5,6
DIMM Thermal Margin Sensors3,5
Exit Air Temperature Sensor1, 4, 8
PCH Temperature Sensor4,6
On-board Ethernet Controller Temperature Sensors4, 6
Add-In Intel SAS/IO Module Temperature Sensors4, 6
PSU Thermal Sensor4, 9
CPU VR Temperature Sensors4, 7
DIMM VR Temperature Sensors4, 7
iBMC Temperature Sensor4, 7
Global Aggregate Thermal Margin Sensors3, 8
Note:
1. For fan speed control in Intel chassis
2. For fan speed control in 3rd party chassis
3. Temperature margin from throttling threshold
4. Absolute temperature
5. PECI value
6. On-die sensor
7. On-board sensor
8. Virtual sensor
9. Available only when PSU has PMBus*
A simplified model is shown as below which gives a high level concept of the fan speed
control structure.
Figure 25. High-level Fan Speed Control Process
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
62 Intel order number G34153-003 Revision 1.2
4.4.7 Power Supply Status\Health Sensors
The BMC supports one Power Supply Status sensor for each system power supply module. In
order to track problems in which the PSU firmware is not operating to full capacity, an additional
case (degraded condition if the PSU firmware is not operating to full capacity) is added to the
existing Power Supply Status sensor offset definitions. This is handled by assertion of the
“configuration error” offset of the PSU status sensor. These sensors are only supported for
systems that use PMBus*-compliant power supplies.
IPMI Sensor Characteristics
1. Event reading type code: 6Fh (Sensor Specific)
2. Event sensor type code: 08h (Power Supply)
3. Rearm type: Auto
The following sensor-specific offsets are supported.
Table 20. Supported Power Supply Status Sensor Offsets
Offset
Description
Event Logging
00h
Presence detected Asserted if power supply module is present. Events
are only logged for power supply presence upon changes in the presence
state after AC power is applied (no events logged for initial state).
Assertion and
Deassertion
01h
Power supply failure detected Asserted if power supply module has failed.
The following codes for failure modes are put into the SEL Event Data 2
byte:
01h - Output voltage fault
02h - Output power fault
03h - Output over-current fault
04h - Over-temperature fault
05h Fan fault
The SEL Event Data 3 byte will have the contents of the associated
PMBus* Status register to allow for showing multiple conditions for the
event. For example, Data 3 will have the contents of the
VOLTAGE_STATUS register at the time an Output Voltage fault was
detected. Refer to the PMBus Specification for details on specific resister
contents
Assertion and
Deassertion
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 63
Offset
Description
Event Logging
02h
Predictive failure Asserted if some condition, such as failing fan, has been
detected that is likely to lead to a power supply module failure.
The following codes for warning modes are put into the SEL Event Data 2
byte:
01h - Output voltage warning
02h - Output power warning
03h - Output over-current warning
04h - Over-temperature warning
05h - Fan warning
06h - Under-voltage warning
07h - Input over-current warning
08h - Input over-power warning
The SEL Event Data 3 byte will have the contents of the associated
PMBus* Status register to allow for showing multiple conditions for the
event. For example, Data 3 will have the contents of the
VOLTAGE_STATUS register at the time an Output Voltage Warning was
detected. Refer to the PMBus Specification for details on specific resister
contents.
Assertion and
Deassertion
03h
Power supply AC lost Asserted if there is no AC power input to power
supply module.
Assertion and
Deassertion
06h
Configuration error The following codes for configuration errors are put
into the SEL Event Data 2 byte:
01h - The BMC cannot access the PMBus* device on the PSU but its
FRU device is responding.
02h - The PMBUS_REVISION command returns a version number that
is not supported (only version 1.1 and 1.2 are supported for platforms
covered under this FW EAS).
03h - The PMBus* device does not successfully respond to the
PMBUS_REVISION command.
04h The PSU is incompatible with one or more PSUs that are
present in the system.
05h The PSU FW is operating in a degraded mode (likely due to a
failed firmware update).
Assertion and
Deassertion
4.4.8 System Event Sensor
The BMC supports a System Event sensor and logs SEL event for following events.
Table 21. Support System Event Sensor Offsets
Offset
Description
Event Logging
02h
OEM code (Undetermined system HW failure)
Assertion and
Deassertion
04h
PEF action
Assertion only
For offset 2, OEM code will be logged in event data byte 2 to indicate the type of failure. Only one value
will be supported at this time, but others may be added in the future. The code for this particular fault will
be 0x00 (PECI access failure) and all other values reserved. Upon detection of the CPU PECI fault
condition, the offset shall assert. It shall deassert upon system power cycle or system reset. Assertion of
offset 02h shall contribute a “fatal” condition to the system status as reflected in the Front Panel system
status LED.
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
64 Intel order number G34153-003 Revision 1.2
4.4.8.1 Update Related SEL Logging
BMC FW will support a single FW Update Status sensor. This sensor is used to generate SEL events
related to update of embedded firmware on the platform. This includes updates to the BMC, BIOS, and
ME FW.
IPMI Sensor Characteristics
1. Event reading type code: 70h (OEM defined)
2. Sensor type code: 2Bh (Version Change)
3. Rearm type: Auto
This sensor is an event-only sensor that is not readable. Event generation is only enabled for
assertion events. Since this is an event-only sensor it should be defined by a type-3 SDR as
defined in the IPMI 2.0 Specification.
Table 22. Supported Firmware Update Status Sensor Offsets
Offset
Description
Event
Logging
Contribution to system
health
00h
Update started
Assertion
OK
01h
Update completed successfully
Assertion
OK
02h
Update failure
Assertion
OK
Event Data Bytes
Byte 2: [Bits 7:4] Target of update
0000b = BMC
0001b = BIOS
0010b = ME
0011b = EWS (Embedded Web server)
All other values reserved
[Bits 3:1] Target instance (zero-based)
[Bits 0:0] Reserved
Byte 3: Reserved
Note: All reserved bits must be set to zero.
4.5 Platform Management Interface
This chapter describes the supported BMC communication interfaces:
1. Host SMS interface by means of low pin count (LPC)/keyboard controller style (KCS)
interface
2. Host SMM interface by means of low pin count (LPC)/keyboard controller style (KCS)
interface
3. Intelligent Platform Management Bus (IPMB) I2C interface
4. LAN interface using the IPMI-over-LAN protocols
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 65
4.5.1 Channel Management
Every messaging interface is assigned an IPMI channel ID by IPMI 2.0. Commands are provided to
configure each channel for privilege levels and access modes. Table 23 shows the standard channel
assignments:
Table 23. Standard Channel Assignments
Channel ID
Interface
Supports
Sessions
0
Primary IPMB
No
1
LAN 1
Yes
2
LAN 2
Yes
3
LAN3 1
(Provided by the Intel® Dedicated Server Management NIC)
Yes
4
Reserved
Yes
5
USB
No
6
Secondary IPMB
No
7
SMM
No
8 0Dh
Reserved
0Eh
Self 2
0Fh
SMS/Receive Message Queue
No
Notes:
1. Optional hardware supported by the server system.
2. Refers to the actual channel used to send the request.
4.5.2 User Model
The BMC supports the IPMI 2.0 user model. 15 user IDs are supported. These 15 users can be assigned
to any channel. The following restrictions are placed on user-related operations:
1. User names for User IDs 1 and 2 cannot be changed. These are always “” (Null/blank) and “root”
respectively.
2. User 2 (“root”) always has the administrator privilege level.
3. All user passwords (including passwords for 1 and 2) may be modified.
4. User IDs 3-15 may be used freely, with the condition that user names are unique. Therefore, no
other users can be named “” (Null), “root,” or any other existing user name.
4.5.3 LAN Interface
The BMC implements both the IPMI 1.5 and IPMI 2.0 messaging models. These provide out-of-band local
area network (LAN) communication between the BMC and the network.
Run-time determination of LAN channel capabilities can be determined by both standard IPMI defined
mechanisms.
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
66 Intel order number G34153-003 Revision 1.2
4.5.3.1 IPMI 1.5 Messaging
The communication protocol packet format consists of IPMI requests and responses encapsulated in an
IPMI session wrapper for authentication, and wrapped in an RMCP packet, which is wrapped in an
IP/UDP packet. Although authentication is provided, no encryption is provided, so administrating some
settings, such as user passwords, through this interface is not advised. Session establishment commands
are IPMI commands that do not require authentication or an associated session.
The BMC supports the following authentication types over the LAN interface.
1. None (no authentication)
2. Straight password/key
3. MD5
4.5.3.2 IPMI 2.0 Messaging
IPMI 2.0 messaging is built over RMCP+ and has a different session establishment protocol. The session
commands are defined by RMCP+ and implemented at the RMCP+ level, not IPMI commands.
Authentication is implemented at the RMCP+ level. RMCP+ provides link payload encryption, so it is
possible to communicate private/sensitive data (confidentiality).
The BMC supports the cipher suites identified in Table 24.
Table 24. Supported RMCP+ Cipher Suites
ID
Authentication Algorithm
Integrity Algorithm(s)
Confidentiality Algorithm(s)
01
RAKP-none
None
None
1
RAKP-HMAC-SHA1
None
None
2
RAKP-HMAC-SHA1
HMAC-SHA1-96
None
3
RAKP-HMAC-SHA1
HMAC-SHA1-96
AES-CBC-128
6
RAKP-HMAC-MD5
None
None
7
RAKP-HMAC-MD5
HMAC-MD5-128
None
8
RAKP-HMAC-MD5
HMAC-MD5-128
AES-CBC-128
11
RAKP-HMAC-MD5
MD5-128
None
12
RAKP-HMAC-MD5
MD5-128
AES-CBC-128
Note: Cipher suite 0 defaults to callback privilege for security purposes. This may be changed by any
administrator.
For user authentication, the BMC can be configured with ‘null’ user names, whereby password/key lookup
is done based on ‘privilege level only’, or with non-null user names, where the key lookup for the session
is determined by user name.
IPMI 2.0 messaging introduces payload types and payload IDs to allow data types other than IPMI
commands to be transferred. IPMI 2.0 serial-over-LAN is implemented as a payload type.
Table 25. Supported RMCP+ Payload Types
Payload Type
Feature
IANA
00h
IPMI message
N/A
01h
Serial-over-LAN
N/A
02h
OEM explicit
Intel (343)
10h 15h
Session setup
N/A
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 67
4.5.3.3 RMCP/ASF Messaging
The BMC supports RMCP ping discovery in which the BMC responds with a pong message to an
RMCP/ASF ping request. This is implemented per the Intelligent Platform Management Interface
Specification Second Generation v2.0.
4.5.3.4 BMC LAN Channels
The BMC supports three RMII/RGMII ports that can be used for communicating with Ethernet devices.
Two ports are used for communication with the on-board NICs and one is used for communication with an
Ethernet PHY located on an optional add-in card (or equivalent on-board circuitry).
4.5.3.4.1 Baseboard NICs
The specific Ethernet controller (NIC) used on a server is platform-specific but all baseboard device
options provide support for an NC-SI manageability interface. This provides a sideband high-speed
connection for manageability traffic to the BMC while still allowing for a simultaneous host access to the
OS if desired.
The Network Controller Sideband Interface (NC-SI) is a DMTF industry standard protocol for the side
band management LAN interface. This protocol provides a fast multi-drop interface for management
traffic.
The baseboard NIC(s) are connected to a single BMC RMII/RGMII port that is configured for RMII
operation. The NC-SI protocol is used for this connection and provides a 100 Mb/s full-duplex multi-drop
interface which allows multiple NICs to be connected to the BMC. The physical layer is based upon RMII,
however RMII is a point-to-point bus whereas NC-SI allows 1 master and up to 4 slaves. The logical layer
(configuration commands) is incompatible with RMII.
Multi-port baseboard NICs on some products will provide support for a dedicated management channel
than can be configured to be hidden from the host and only used by the BMC. This mode of operation is
configured by a BIOS setup option.
4.5.3.4.2 Dedicated Management Channel
An additional LAN channel dedicated to BMC usage and not available to host SW is supported
by an optional add-in card. There is only a PHY device present on the add-in card. The BMC
has a built-in MAC module that uses the RGMII interface to link with the card’s PHY. Therefore,
for this dedicated management interface, the PHY and MAC are located in different devices.
The PHY on the card connects to the BMC’s other RMII/RGMII interface (that is, the one that is
not connected to the baseboard NICs). This BMC port is configured for RGMII usage.
In addition to the use of an add-in card for a dedicated management channel, on systems that
support multiple Ethernet ports on the baseboard, the system BIOS provides a setup option to
allow one of these baseboard ports to be dedicated to the BMC for manageability purposes.
When this is enabled, that port is hidden from the OS.
4.5.3.4.3 Concurrent Server Management Use of Multiple Ethernet Controllers
Provided the HW supports a management link between the BMC and a NIC port, the BMC FW
supports concurrent OOB LAN management sessions for the following combination:
Two on-board NIC ports
One on-board NIC and the optional dedicated add-in management NIC.
Two on-board NICs and optional dedicated add-in management NIC.
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
68 Intel order number G34153-003 Revision 1.2
All NIC ports must be on different subnets for the above concurrent usage models.
MAC addresses are assigned for management NICs from a pool of up to 3 MAC addresses allocated
specifically for manageability. The total number of MAC addresses in the pool is dependent on the
product HW constraints (for example,a board with 2 NIC ports available for manageability would have a
MAC allocation pool of 2 addresses).For these channels, support can be enabled for IPMI-over-LAN and
DHCP.
For security reasons, embedded LAN channels have the following default settings:
IP Address: Static
All users disabled
IPMI-enabled network interfaces may not be placed on the same subnet. This includes the Intel®
Dedicated Server Management NIC and either of the BMC’s embedded network interfaces.
Host-BMC communication over the same physical LAN connection also known as “loopback” – is not
supported. This includes “ping” operations.
On baseboards with more than two onboard NIC ports, only the first two ports can be used as BMC LAN
channels. The remaining ports have no BMC connectivity.
Maximum bandwidth supported by BMC LAN channels are as follows:
BMC LAN1 (Baseboard NIC port) ----- 100M (10M in DC off state)
BMC LAN 2 (Baseboard NIC port) ----- 100M (10M in DC off state)
BMC LAN 3 (Dedicated NIC) ----- 1000M
4.5.3.5 Dedicated Management NIC MAC Address
For EPSD Platforms Based on Intel® Xeon® Processor E5 4600/2600/2400/1600/1400 Product Families
each server board has either five or seven MAC addresses assigned to it at the Intel factory. The printed
MAC address is assigned to NIC1 on the server board.
If the platform has two NIC built into the main board then there will be five MAC addresses assigned as
follows:
NIC 1 MAC address (for OS usage)
NIC 2 MAC address = NIC 1 MAC address + 1 (for OS usage)
BMC LAN channel 1 MAC address = NIC1 MAC address + 2
BMC LAN channel 2 MAC address = NIC1 MAC address + 3
BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 4
If the platform has four NIC built into the main board then there will be seven MAC addresses assigned as
follows:
NIC 1 MAC address (for OS usage)
NIC 2 MAC address = NIC 1 MAC address + 1 (for OS usage)
NIC 3 MAC address = NIC 1 MAC address + 2 (for OS usage)
NIC 4 MAC address = NIC 1 MAC address + 3 (for OS usage)
BMC LAN channel 1 MAC address = NIC1 MAC address + 4
BMC LAN channel 2 MAC address = NIC1 MAC address + 5
BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 6.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 69
4.5.3.6 IPV6 Support
In addition to IPv4, Intel® S1400/S1600/S2400/S2600 Server Platforms support IPv6 for manageability
channels. Configuration of IPv6 is provided by extensions to the IPMI Set and Get LAN Configuration
Parameters commands as well as through a Web Console IPv6 configuration web page.
The BMC supports IPv4 and IPv6 simultaneously so they are both configured separately and completely
independently. For example, IPv4 can be DHCP configured while IPv6 is statically configured or vice
versa.
4.5.3.6.1 LAN Failover
The BMC FW provides a LAN failover capability such that the failure of the system HW
associated with one LAN link will result in traffic being rerouted to an alternate link. This
functionality is configurable by IPMI methods as well as by the BMC’s Embedded UI, allowing
for user to specify the physical LAN links constitute the redundant network paths or physical
LAN links constitute different network paths. BMC will support only a all or nothing” approach –
that is, all interfaces bonded together, or none are bonded together.
The LAN Failover feature applies only to BMC LAN traffic. It bonds all available Ethernet
devices but only one is active at a time. When enabled, If the active connection’s leash is lost,
one of the secondary connections is automatically configured so that it has the same IP address
(the next active LAN link will be chosen randomly from the pool of backup LAN links with link
status as “UP”). Traffic immediately resumes on the new active connection.
The LAN Failover enable/disable command may be sent at any time. After it has been enabled,
standard IPMI commands for setting channel configuration that specify a LAN channel other
than the first will return an error code.
Standard IPMI commands for getting channel configuration will return the cached settings for the inactive
channels.
4.5.3.7 BMC IP Address Configuration
Enabling the BMC’s network interfaces requires using the Set LAN Configuration Parameter command to
configure LAN configuration parameter 4, IP Address Source.
4.5.3.8 DHCP BMC Hostname
The BMC allows setting a DHCP Hostname. DHCP Hostname can be set regardless of the IP Address
source configured on the BMC. But this parameter is only used if the IP Address source is set to DHCP.
4.5.3.9 Address Resolution Protocol (ARP)
The BMC can receive and respond to ARP requests on BMC NICs. Gratuitous ARPs are supported, and
disabled by default.
4.5.3.10 Virtual Local Area Network (VLAN)
The BMC supports VLAN as defined by IPMI 2.0 specifications. VLAN is supported internally by the BMC,
not through switches. VLAN provides a way of grouping a set of systems together so that they form a
logical network. This feature can be used to set up a management VLAN where only devices which are
members of the VLAN will receive packets related to management and members of the VLAN will be
isolated from any other network traffic. Please note that VLAN does not change the behavior of the host
network setting, it only affects the BMC LAN communication.
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
70 Intel order number G34153-003 Revision 1.2
LAN configuration options are now supported (by means of the Set LAN Config Parameters command,
parameters 20 and 21) that allow support for 802.1Q VLAN (Layer 2). This allows VLAN headers/packets
to be used for IPMI LAN sessions. VLAN ID’s are entered and enabled by means of parameter 20 of the
Set LAN Config Parameters IPMI command. When a VLAN ID is configured and enabled, the BMC only
accepts packets with that VLAN tag/ID. Conversely, all BMC generated LAN packets on the channel
include the given VLAN tag/ID. Valid VLAN ID’s are 1 through 4094, VLAN ID’s of 0 and 4095 are
reserved, per the 802.1Q VLAN specification. Only one VLAN can be enabled at any point in time on a
LAN channel. If an existing VLAN is enabled, it must first be disabled prior to configuring a new VLAN on
the same LAN channel.
Parameter 21 (VLAN Priority) of the Set LAN Config Parameters IPMI command is now implemented and
a range from 0-7 will be allowed for VLAN Priorities. Please note that bits 3 and 4 of Parameter 21 are
considered Reserved bits.
Parameter 25 (VLAN Destination Address) of the Set LAN Config Parameters IPMI command is not
supported and returns a completion code of 0x80 (parameter not supported) for any read/write of
parameter 25.
If the BMC IP address source is DHCP, then the following behavior is seen:
If the BMC is first configured for DHCP (prior to enabling VLAN), when VLAN is enabled,
the BMC performs a discovery on the new VLAN in order to obtain a new BMC IP address.
If the BMC is configured for DHCP (before disabling VLAN), when VLAN is disabled, the
BMC performs a discovery on the LAN in order to obtain a new BMC IP address.
If the BMC IP address source is Static, then the following behavior is seen:
If the BMC is first configured for static (prior to enabling VLAN), when VLAN is enabled,
the BMC has the same IP address that was configured before. It is left to the management
application to configure a different IP address if that is not suitable for VLAN.
If the BMC is configure for static (prior to disabling VLAN), when VLAN is disabled, the
BMC has the same IP address that was configured before. It is left to the management
application to configure a different IP address if that is not suitable for LAN.
4.5.3.11 Secure Shell (SSH)
Secure Shell (SSH) connections are supported for one SMASH-CLP session to the BMC.
4.5.3.12 Serial-over-LAN (SOL 2.0)
The BMC supports IPMI 2.0 SOL.
IPMI 2.0 introduced a standard serial-over-LAN feature. This is implemented as a standard payload type
(01h) over RMCP+.
Three commands are implemented for SOL 2.0 configuration.
1. “Get SOL 2.0 Configuration Parameters” and “Set SOL 2.0 Configuration Parameters”: These
commands are used to get and set the values of the SOL configuration parameters. The parameters
are implemented on a per-channel basis.
2. “Activating SOL”: This command is not accepted by the BMC. It is sent by the BMC when SOL is
activated to notify a remote client of the switch to SOL.
3. Activating a SOL session requires an existing IPMI-over-LAN session. If encryption is used, it should
be negotiated when the IPMI-over LAN session is established. Intel® Server Board S2600IP SOL
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 71
sessions are supported on serial port A (COM1). Intel® Workstation Board S2600IP SOL sessions are
supported on serial port B (COM2).
4.5.3.13 Platform Event Filter (PEF)
The BMC includes the ability to generate a selectable action, such as a system power-off or reset, when a
match occurs to one of a configurable set of events. This capability is called Platform Event Filtering, or
PEF. One of the available PEF actions is to trigger the BMC to send a LAN alert to one or more
destinations.
The BMC supports 20 PEF filters. The first twelve entries in the PEF filter table are pre-configured (but
may be changed by the user). The remaining entries are left blank, and may be configured by the user.
Table 26. Factory Configured PEF Table Entries
Event Filter
Number
Offset Mask
Events
1
Non-critical, critical and non-
recoverable
Temperature sensor out of range
2
Non-critical, critical and non-
recoverable
Voltage sensor out of range
3
Non-critical, critical and non-
recoverable
Fan failure
4
General chassis intrusion
Chassis intrusion (security violation)
5
Failure and predictive failure
Power supply failure
6
Uncorrectable ECC
BIOS
7
POST error
BIOS: POST code error
8
FRB2
Watchdog Timer expiration for FRB2
9
Policy Correction Time
Node Manager
10
Power down, power cycle, and reset
Watchdog timer
11
OEM system boot event
System restart (reboot)
12
Drive Failure, Predicted Failure
Hot Swap Controller
Additionally, the BMC supports the following PEF actions:
Power off
Power cycle
Reset
OEM action
Alerts
The “Diagnostic interrupt” action is not supported.
4.5.3.14 LAN Alerting
The BMC supports sending embedded LAN alerts, called SNMP PET (Platform Event traps), and SMTP
email alerts.
The BMC supports a minimum of four LAN alert destinations.
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
72 Intel order number G34153-003 Revision 1.2
4.5.3.14.1 SNMP Platform Event Traps (PETs)
This feature enables a target system to send SNMP traps to a designated IP address by means of LAN.
These alerts are formatted per the Intelligent Platform Management Interface Specification Second
Generation v2.0. A MIB file associated with the traps is provided with the BMC firmware to facilitate
interpretation of the traps by external software.
The format of the MIB file is covered under RFC 2578.
4.5.3.15 Alert Policy Table
Associated with each PEF entry is an alert policy that determines which IPMI channel the alert is to be
sent. There is a maximum of 20 alert policy entries. There are no pre-configured entries in the alert policy
table because the destination types and alerts may vary by user. Each entry in the alert policy table
contains four bytes for a maximum table size of 80 bytes.
4.5.3.15.1 E-mail Alerting
The Embedded Email Alerting feature allows the user to receive e-mails alerts indicating issues with the
server. This allows e-mail alerting in an OS-absent (for example, Pre-OS and OS-Hung) situation. This
feature provides support for sending e-mail by means of SMTP, the Simple Mail Transport Protocol as
defined in Internet RC 821. The e-mail alert provides a text string that describes a simple description of
the event. SMTP alerting is configured using the embedded web server.
4.5.3.16 SM-CLP (SM-CLP Lite)
SMASH refers to Systems Management Architecture for Server Hardware. SMASH is defined
by a suite of specifications, managed by the DMTF, that standardize the manageability
interfaces for server hardware. CLP refers to Command Line Protocol. SM-CLP is defined by
the Server Management Command Line Protocol Specification (SM-CLP) ver1.0, which is part
of the SMASH suite of specifications. The specifications and further information on SMASH can
be found at the DMTF website (http://www.dmtf.org/).
The BMC provides an embedded “lite” version of SM-CLP that is syntax-compatible but not
considered fully compliant with the DMTF standards.
4.5.3.17 Embedded Web Server
BMC Base manageability provides an embedded web server and an OEM-customizable web
GUI which exposes the manageability features of the BMC base feature set. It is supported
over all on-board NICs that have ma nagement connectivity to the BMC as well as an optional
dedicated add-in management NIC. At least two concurrent web sessions from up to two
different users is supported. The embedded web user interface shall support the following
client web browsers:
Microsoft Internet Explorer 7.0*
Microsoft Internet Explorer 8.0*
Microsoft Internet Explorer 9.0*
Mozilla Firefox 3.0*
Mozilla Firefox 3.5*
Mozilla Firefox 3.6*
The embedded web user interface supports strong security (authentication, encryption, and
firewall support) since it enables remote server configuration and control. Embedded web server
uses ports #80 and #443. The user interface presented by the embedded web user interface
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 73
shall authenticate the user before allowing a web session to be initiated. Encryption using 128-
bit SSL is supported. User authentication is based on user id and password.
The GUI presented by the embedded web server authenticates the user before allowing a web
session to be initiated. It presents all functions to all users but grays-out those functions that the
user does not have privilege to execute. (For example, if a user does not have privilege to
power control, then the item shall be displayed in grey-out font in that user’s UI display). The
web GUI also provides a launch point for some of the advanced features, such as KVM and
media redirection. These features are grayed out in the GUI unless the system has been
updated to support these advanced features.
Additional features supported by the web GUI includes:
Presents all the Basic features to the users.
Power on/off/reset the server and view current power state.
Displays BIOS, BMC, ME and SDR version information.
Display overall system health.
Configuration of various IPMI over LAN parameters for both IPV4 and IPV6
Configuration of alerting (SNMP and SMTP).
Display system asset information for the product, board, and chassis.
Display of BMC-owned sensors (name, status, current reading, enabled thresholds),
including color-code status of sensors.
Provides ability to filter sensors based on sensor type (Voltage, Temperature, Fan and
Power supply related)
Automatic refresh of sensor data with a configurable refresh rate.
On-line help.
Display/clear SEL (display is in easily understandable human readable format).
Supports major industry-standard browsers (Microsoft Internet Explorer* and Mozilla
Firefox*).
The GUI session automatically times-out after a user-configurable inactivity period. By
default, this inactivity period is 30 minutes.
Embedded Platform Debug feature - Allow the user to initiate a “diagnostic dump” to a
file that can be sent to Intel for debug purposes.
Virtual Front Panel. The Virtual Front Panel provides the same functionality as the local
front panel. The displayed LEDs match the current state of the local panel LEDs. The
displayed buttons (for example,power button) can be used in the same manner as the
local buttons.
Display of ME sensor data. Only sensors that have associated SDRs loaded will be
displayed.
Ability to save the SEL to a file.
Ability to force HTTPS connectivity for greater security. This is provided through a
configuration option in the UI.
Display of processor and memory information as is available over IPMI over LAN.
Ability to get and set Node Manager (NM) power policies.
Display of power consumed by the server.
Ability to view and configure VLAN settings.
Warn user the reconfiguration of IP address will cause disconnect.
Capability to block logins for a period of time after several consecutive failed login
attempts. The lock-out period and the number of failed logins that initiates the lock-out
period are configurable by the user.
Server Power Control - Ability to force into Setup on a reset.
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
74 Intel order number G34153-003 Revision 1.2
4.5.3.18 Virtual Front Panel
Virtual Front Panel is the module present as “Virtual Front Panel” on the left side in the
embedded web server when "remote Control" tab is clicked.
Main Purpose of the Virtual Front Panel is to provide the front panel functionality virtually.
Virutal Front Panel (VFP) will mimic the status LED and Power LED status and Chassis ID
alone. It is automatically in sync with BMC every 40 seconds.
For any abnormal status LED state, Virtual Front Panel will get the reason behind the
abnormal or status LED changes and displayed in VFP side.
As Virtual Front Panel uses the chassis control command for power actions. It won’t log
the Front button press event since Logging the front panel press event for Virtual Front
Panel press will mislead the administrator.
For Reset from Virtual Front Panel, the reset will be done by a “Chassis control” command.
For Reset from Virtual Front Panel, the restart cause will be because of “Chassis control
command.
During Power action, Power button/Reset button should not accept the next action until
current Power action is complete and the acknowledgment from BMC is received.
EWS will provide a valid message during Power action until it completes the current Power
action.
The VFP does not have any effect on whether the front panel is locked by “Set Front Panel
Enables” command.
The chassis ID LED provides a visual indication of a system being serviced. The state of
the chassis ID LED is affected by the following actions:
Toggled by turning the chassis ID button on or off.
There is no precedence or lock-out mechanism for the control sources. When a new
request arrives, previous requests are terminated. For example, if the chassis ID button is
pressed, then the chassis ID LED changes to solid on. If the button is pressed again, then
the chassis ID LED turns off.
Note that the chassis ID will turn on because of the original chassis ID button press and
will reflect in the Virtual Front Panel after VFP sync with BMC. Virtual Front Panel won’t
reflect the chassis LED software blinking by the software command as there is no
mechanism to get the chassis ID Led status.
Only Infinite chassis ID ON/OFF by the software command will reflect in EWS during
automatic /manual EWS sync up with BMC.
Virtual Front Panel help should available for virtual panel module.
At present, NMI button in VFP is disabled in Intel® S1400/S1600/S2400/S2600 Server
Platforms. It can be used in future.
4.5.3.19 Embedded Platform Debug
The Embedded Platform Debug feature supports capturing low-level diagnostic data (applicable MSRs,
PCI config-space registers, and so on). This feature allows a user to export this data into a file that is
retrievable from the embedded web GUI, as well as through host and remote IPMI methods, for the
purpose of sending to an Intel engineer for an enhanced debugging capability. The files are compressed,
encrypted, and password protected. The file is not meant to be viewable by the end user but rather to
provide additional debugging capability to an Intel support engineer.
4.5.3.20 Data Center Management Interface (DCMI)
The DCMI Specification is an emerging standard that is targeted to provide a simplified management
interface for Internet Portal Data Center (IPDC) customers. It is expected to become a requirement for
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 75
server platforms which are targeted for IPDCs. DCMI is an IPMI-based standard that builds upon a set of
required IPMI standard commands by adding a set of DCMI-specific IPMI OEM commands. Intel®
S1400/S1600/S2400/S2600 Server Platforms will be implementing the mandatory DCMI features in the
BMC firmware (DCMI 1.1 Errata 1 compliance). Please refer to DCMI 1.1 errata 1 spec for details. Only
mandatory commands will be supported. No support for optional DCMI commands. Optional power
management and SEL roll over feature is not supported. DCMI Asset tag will be independent of
baseboard FRU asset Tag. Please refer table DCMI Group Extension Commands for more details on
DCMI commands.
4.5.3.21 Lightweight Directory Authentication Protocol (LDAP)
The Lightweight Directory Access Protocol (LDAP) is an application protocol supported by the BMC for
the purpose of authentication and authorization. The BMC user connects with an LDAP server for login
authentication. This is only supported for non-IPMI logins including the embedded web UI and SM-CLP.
IPMI users/passwords and sessions are not supported over LDAP.
LDAP can be configured (IP address of LDAP server, port, and so on) from the BMC’s Embedded Web UI.
LDAP authentication and authorization is supported over the any NIC configured for system management.
The BMC uses a standard Open LDAP implementation for Linux.
Only open LDAP is supported by BMC. Windows and Novel LDAP are not supported.
4.6 BMC Firmware Update
4.6.1 The BMC firmware release Number
The BMC firmware releases are numbered as follows:
AB.CD.XXX
Where:
CD is a two digit number starting with 00 for the first release. This is the number returned in minor ID in
Get Device ID response.
B is major release number (1 for the first major release typically at first production shipment).
A is point release indicator (A=0 means this is a regular official release, A=1 means this is a point release
for limited distribution). A hex representation of “AB” is returned in major ID in Get Device ID response.
XXX is the build number for internal tracking. This number is returned in OEM bytes of Get Device ID
response.
4.6.2 Boot Recovery Mode
The BMC’s boot block supports firmware transfer updates. The Operational Firmware Transfer mode
preserves several files in the PIA Linux file system. Boot Recovery mode cannot preserve the files
because it does not understand Linux file systems, and treats it as a large binary data section. This
means a Boot Recovery update completely replaces the PIA with the factory default version: an empty
SEL, a default SDR, and default IPMI configuration and user settings.
Boot Recovery mode can successfully complete an update in some situations where the Operational
Firmware Transfer mode will fail. If there is an incompatibility or bug in the operational code causing it to
crash or hang, only a Boot Recovery Mode Update works. Another example is if the flash layout of the
sections changes across an update. Because the operational Firmware Transfer mode tries to preserve
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
76 Intel order number G34153-003 Revision 1.2
the contents of the PIA section, in this case, it will corrupt the flash where the old PIA section was.
Because the Boot Recovery mode is blindly writing binary data to flash, in this case, it will succeed.
There are two ways to enter Boot Recovery mode:
The Force Firmware Update jumper is asserted when A/C power is applied.
The operational code is corrupt and the boot loader cannot boot.
In the Boot Recovery mode, the BMC only responds to the small set of commands listed above. Only the
KCS SMS interface is supported; USB-based Fast Firmware Update is not supported.
4.6.3 Force Firmware Update Jumper
The Force Firmware Update jumper can be used to put the BMC in Boot Recovery mode for a low-level
update. It causes the BMC to abort its normal boot process and stay in the boot loader without executing
any Linux code.
The jumper is normally in the de-asserted position. The system must be completely powered off (A/C
power removed) before the jumper is moved. After power is re-applied and the firmware update is
complete, the system must be powered off again and the jumper must be returned to the de-asserted
position before normal operation can begin.
There is no bootblock-write protection jumper.
4.6.4 Fast Firmware Update over USB
The BMC supports a Fast Firmware Update mode in addition to the standard KCS SMS interface. This is
a special protocol that goes over the USB connection between the host and the BMC.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 77
4.7 Advanced Management Feature Support
This section explains the advanced management features supported by the BMC firmware.
4.7.1 Enabling Advanced Management Features
The Advanced management features are to be delivered as part of the BMC FW image. The
BMC’s baseboard SPI flash contains code/data for both the Basic and Advanced features. An
optional add-in card Intel® RMM4 lite is used as the activation mechanism. When the BMC FW
initializes, it attempts to access the Intel® RMM4 lite. If the attempt to access Intel® RMM4 lite is
successful, then the BMC activates the Advanced features.
Advanced manageability features are supported over all NIC ports enabled for server
manageability. This includes baseboard NICs as well as the LAN channel provided by the
optional Dedicated NIC add-in card.
RMM4 is comprised of two boards RMM4 lite and the optional Dedicated Server Management NIC
(DMN). If the optional Dedicated Server Management NIC is not used then the traffic can only go through
the onboard Integrated BMC-shared NIC and share network bandwidth with the host system.
Table 27. Enabling Advanced Management Features
Manageability Hardware
Benefits
Intel® Integrated BMC
Comprehensive IPMI based base manageability
features
Intel® Remote Management Module 4 Lite
Package contains one module
1- Key for advance Manageability features.
No dedicated NIC for management
Enables KVM and media redirection from the onboard
NIC
Intel® Remote Management Module 4
Package includes 2 modules
1 - key for advance features
2 - Dedicated NIC (1Gbe) for management
Dedicated NIC for management traffic. Higher
bandwidth connectivity for KVM and media
Redirection with 1Gbe NIC.
4.7.2 Keyboard, Video, Mouse (KVM) Redirection
The BMC firmware supports keyboard, video, and mouse redirection (KVM) over LAN. This feature is
available remotely from the embedded web server as a Java applet. This feature is only enabled when
the Intel® RMM4 lite is present. The client system must have a Java Runtime Environment (JRE) version
6.0 or later to run the KVM or media redirection applets.
The BMC supports an embedded KVM application (Remote Console) that can be launched from
the embedded web server from a remote console. USB1.1 or USB 2.0 based mouse and
keyboard redirection are supported. It is also possible to use the KVM-redirection (KVM-r)
session concurrently with media-redirection (media-r). This feature allows a user to interactively
use the keyboard, video, and mouse (KVM) functions of the remote server as if the user were
physically at the managed server.
KVM redirection console support the following keyboard layouts: English, Dutch, French,
German, Italian, Russian, and Spanish.
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
78 Intel order number G34153-003 Revision 1.2
KVM redirection includes a “soft keyboard” function. The “soft keyboard” is used to simulate an
entire keyboard that is connected to the remote system. The “soft keyboard” functionality
supports the following layouts: English, Dutch, French, German, Italian, Russian, and Spanish.
The KVM-redirection feature automatically senses video resolution for best possible screen
capture and provides high-performance mouse tracking and synchronization. It allows remote
viewing and configuration in pre-boot POST and BIOS setup, once BIOS has initialized video.
Other attributes of this feature include:
Encryption of the redirected screen, keyboard, and mouse
Compression of the redirected screen.
Ability to select a mouse configuration based on the OS type.
supports user definable keyboard macros.
KVM redirection feature supports the following resolutions and refresh rates:
640x480 at 60Hz, 72Hz, 75Hz, 85Hz, 100Hz
800x600 at 60Hz, 72Hz, 75Hz, 85Hz
1024x768 at 60Hx, 72Hz, 75Hz, 85Hz
1280x960 at 60Hz
1280x1024 at 60Hz
1600x1200 at 60Hz
1920x1080 (1080p),
1920x1200 (WUXGA)
1650x1080 (WSXGA+)
4.7.2.1 Force-enter BIOS Setup
KVM redirection can present an option to force-enter BIOS Setup. This enables the system to enter F2
setup while booting which is often missed by the time the remote console redirects the video.
4.7.3 Media Redirection
The embedded web server provides a Java applet to enable remote media redirection. This may be used
in conjunction with the remote KVM feature, or as a standalone applet.
The media redirection feature is intended to allow system administrators or users to mount a
remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server.
Once mounted, the remote device appears just like a local device to the server, allowing system
administrators or users to install software (including operating systems), copy files, update BIOS,
and so on, or boot the server from this device.
The following capabilities are supported:
The operation of remotely mounted devices is independent of the local devices on the
server. Both remote and local devices are useable in parallel.
Either IDE (CD-ROM, floppy) or USB devices can be mounted as a remote device to the
server.
It is possible to boot all supported operating systems from the remotely mounted device
and to boot from disk IMAGE (*.IMG ) and CD-ROM or DVD-ROM ISO files. See the
Tested/supported Operating System List for more information.
Media redirection supports redirection for both a virtual CD device and a virtual
Floppy/USB device concurrently. The CD device may be either a local CD drive or else an
ISO image file; the Floppy/USB device may be either a local Floppy drive, a local USB
device, or else a disk image file.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 79
The media redirection feature supports multiple encryption algorithms, including RC4 and
AES. The actual algorithm that is used is negotiated with the client based on the client’s
capabilities.
A remote media session is maintained even when the server is powered-off (in standby
mode). No restart of the remote media session is required during a server reset or power
on/off. An BMC reset (for example,due to an BMC reset after BMC FW update) will require
the session to be re-established
The mounted device is visible to (and useable by) managed system’s OS and BIOS in both
pre-boot and post-boot states.
The mounted device shows up in the BIOS boot order and it is possible to change the
BIOS boot order to boot from this remote device.
It is possible to install an operating system on a bare metal server (no OS present) using
the remotely mounted device. This may also require the use of KVM-r to configure the OS
during install.
USB storage devices will appear as floppy disks over media redirection. This allows for the installation of
device drivers during OS installation.
If either a virtual IDE or virtual floppy device is remotely attached during system boot, both the virtual IDE
and virtual floppy are presented as bootable devices. It is not possible to present only a single-mounted
device type to the system BIOS.
Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
80 Intel order number G34153-003 Revision 1.2
4.8 Intel®
Intelligent Power Node Manager (NM)
4.8.1 Overview
Power management deals with requirements to manage processor power consumption and
manage power at the platform level to meet critical business needs. Node Manager (NM) is a
platform resident technology that enforces power capping and thermal-triggered power capping
policies for the platform. These policies are applied by exploiting subsystem knobs (such as
processor P and T states) that can be used to control power consumption. NM enables data
center power management by exposing an external interface to management software through
which platform policies can be specified. It also implements specific data center power
management usage models such as power limiting, and thermal monitoring.
The NM feature is implemented by a complementary architecture utilizing the ME, BMC, BIOS, and an
ACPI-compliant OS. The ME provides the NM policy engine and power control/limiting functions (referred
to as Node Manager or NM) while the BMC provides the external LAN link by which external management
software can interact with the feature. The BIOS provides system power information utilized by the NM
algorithms and also exports ACPI Source Language (ASL) code used by OS-Directed Power
Management (OSPM) for negotiating processor P and T state changes for power limiting. PMBus*-
compliant power supplies provide the capability to monitoring input power consumption, which is
necessary to support NM.
4.8.1.1 Hardware Requirements
NM is supported only on platforms that have the NM FW functionality loaded and enabled on the
Management Engine (ME) in the SSB and that have a BMC present to support the external LAN interface
to the ME. NM power limiting features requires a means for the ME to monitor input power consumption
for the platform. This capability is generally provided by means of PMBus*-compliant power supplies
although an alternative model using a simpler SMBus* power monitoring device is possible (there is
potential loss in accuracy and responsiveness using non-PMBus* devices). The NM SmaRT/CLST
feature does specifically require PMBus*-compliant power supplies as well as additional hardware on the
baseboard.
4.8.1.2 Features
NM provides feature support for policy management, monitoring and querying, alerts and notifications,
and an external interface protocol. The policy management features implement specific IT goals that can
be specified as policy directives for NM. Monitoring and querying features enable tracking of power
consumption. Alerts and notifications provide the foundation for automation of power management in the
data center management stack. The external interface specifies the protocols that must be supported in
this version of NM.
4.8.1.3 ME Firmware Update
On server platforms, the ME FW uses a single operational image with a limited-functionality
recovery image. In order to upgrade an operational image, a boot to recovery image must be
performed. Unlike last generation platforms, the ME FW does not support an IPMI update
mechanism except for the case that the system is configured with a dual-ME (redundant) image.
In order to conserve flash space, which the ME FW shares with BIOS, EPSD systems only
support a single ME image. For this case, ME update is only supported by means of BIOS
performing a direct update of the flash component. The recovery image only provides the basic
functionality that is required to perform the update; therefore other ME FW features are not
functional therefore when the update is in progress.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Platform Management Overview
Revision 1.2 Intel order number G34153-003 81
4.8.1.4 SmaRT/CLST
The power supply optimization provided by SmaRT/CLST relies on a platform HW capability as well as
ME FW support. When a PMBus*-compliant power supply detects insufficient input voltage, an
overcurrent condition, or an over-temperature condition, it will assert the SMBAlert# signal on the power
supply SMBus* (that is, the PMBus*). Through the use of external gates, this results in a momentary
assertion of the PROCHOT# and MEMHOT# signals to the processors, thereby throttling the processors
and memory. The ME FW also sees the SMBAlert# assertion, queries the power supplies to determine
the condition causing the assertion, and applies an algorithm to either release or prolong the throttling,
based on the situation.
System power control modes include:
1. SmaRT: Low AC input voltage event; results in a onetime momentary throttle for each
event to the maximum throttle state
2. Electrical Protection CLST: High output energy event; results in a throttling hiccup mode
with fixed maximum throttle time and a fix throttle release ramp time.
3. Thermal Protection CLST: High power supply thermal event; results in a throttling hiccup
mode with fixed maximum throttle time and a fix throttle release ramp time.
When the SMBAlert# signal is asserted, the fans will be gated by HW for a short period (~100ms) to
reduce overall power consumption. It is expected that the interruption to the fans will be of short enough
duration to avoid false lower threshold crossings for the fan tach sensors; however, this may need to be
comprehended by the fan monitoring FW if it does have this side-effect.
ME FW will log an event into the SEL to indicate when the system has been throttled by the
SmaRT/CLST power management feature. This is dependent on ME FW support for this sensor. Please
refer ME FW EPS for SEL log details.
4.8.1.4.1 Dependencies on PMBus*-compliant Power Supply Support
The SmaRT/CLST system feature depends on functionality present in the ME NM SKU. This feature
requires power supplies that are compliant with the PMBus Specification, Revision 1.2.
4.9 EU Lot 6 Mode
The European Union has set forth a stringent standby power consumption target for systems that are
used as primary computing devices in office environments. Owing to the fact in office environments,
pedestal servers are being used more and more as workstations and that Value servers could make their
way into Home servers, this solution is being requested for some pedestal servers. HW support for EU
Lot6 will only be available for specific EPSD pedestal products.
In order to meet the standby power requirements for EU Lot6 it is necessary to remove power to the BMC,
along with other components, when in the S5 state. As this operational mode impacts system feature
support, the user has the option of enabling and disabling this mode from the BIOS setup screen utility.
BIOS is responsible for enabling/disabling the system hardware for EU Lot6 operation. It notifies the BMC
of the current state with the OEM command Set EULot6 Mode. The BMC saves the state in persistent
store and uses it to control special EU Lot6 internal processing during boot, sensor monitoring, and so on
as needed.
Wake-on-LAN (WOL) is not supported in EU Lot6 mode.
4.9.1.1 Impact to System Features
The following system features are lost or impacted when EU Lot6 mode is enabled:
Increased boot time (~15-20s) when system is DC power cycled.
System Security Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
82 Intel order number G34153-003 Revision 1.2
o This is due to the fact that both the BMC and BIOS are booting at the same time
when the system is powered on (to S0 state). BIOS will need to allow extra time
for the BMC to initialize to the point where it can communicate with BIOS.
Note: Even when EU Lot6 is not enabled and the system is AC cycled, this
increased boot time is applicable if a user immediately attempts to power the system
up (for example, pressing the power button), as in this case both the BMC and BIOS
are booting at the same time.
No LAN manageability when on standby, and therefore no remote OOB power on by
BMC.
No support for SOL or KVM for monitoring the entire boot process.
o Since BMC is initializing at the same time as BIOS, it will not be possible to have
an SOL or KVM session established from the beginning of the system boot.
FP status LED will behave differently (it will be off when on standby) rather than showing
fault conditions present at the time the system was powered down.
No beep code due to uninstalled CPU.
No monitoring of any sensors when on standby.
No detection/logging of any ThermTrip faults.
o These result as the system is shut down by HW so BMC will not be available to
detect that they occurred.
Sensor monitoring after DC power-on will be delayed by the time it takes BMC to
initialize its sensor subsystem (~15 to 20s), possibly losing SEL events or failing to
provide correct FP LED status LED indication.
Note: This delay occurs on each AC cycle even when EU Lot6 mode is disabled.
Chassis intrusion not detected when in standby
5. System Security
5.1 BIOS Password Protection
The BIOS uses passwords to prevent unauthorized tampering with the server setup. Passwords
can restrict entry to the BIOS Setup, restrict use of the Boot Popup menu, and suppress
automatic USB device reordering.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS System Security
Revision 1.2 Intel order number G34153-003 83
There is also an option to require a Power On password entry in order to boot the system. If the
Power On Password function is enabled in Setup, the BIOS will halt early in POST to request a
password before continuing POST.
Both Administrator and User passwords are supported by the BIOS. An Administrator password
must be installed in order to set the User password. The maximum length of a password is
14 characters. A password can have alphanumeric (a-z, A-Z, 0-9) characters and it is case
sensitive. Certain special characters are also allowed, from the following set:
! @ # $ % ^ & * ( ) - _ + = ?
The Administrator and User passwords must be different from each other. An error message will
be displayed if there is an attempt to enter the same password for one as for the other.
The use of “Strong Passwords” is encouraged, but not required. In order to meet the criteria for
a “Strong Password”, the password entered must be at least 8 characters in length, and must
include at least one each of alphabetic, numeric, and special characters. If a “weak” password is
entered, a popup warning message will be displayed, although the weak password will be
accepted.
Once set, a password can be cleared by changing it to a null string. This requires the
Administrator password, and must be done through BIOS Setup or other explicit means of
changing the passwords. Clearing the Administrator password will also clear the User password.
Alternatively, the passwords can be cleared by using the Password Clear jumper if necessary.
Resetting the BIOS configuration settings to default values (by any method) has no effect on the
Administrator and User passwords.
Entering the User password allows the user to modify only the System Time and System Date in
the Setup Main screen. Other setup fields can be modified only if the Administrator password
has been entered. If any password is set, a password is required to enter the BIOS setup.
The Administrator has control over all fields in the BIOS setup, including the ability to clear the
User password and the Administrator password.
It is strongly recommended that at least an Administrator Password be set, since not having set
a password gives everyone who boots the system the equivalent of Administrative access.
Unless an Administrator password is installed, any User can go into Setup and change BIOS
settings at will.
In addition to restricting access to most Setup fields to viewing only when a User password is
entered, defining a User password imposes restrictions on booting the system. In order to
simply boot in the defined boot order, no password is required. However, the F6 Boot popup
prompts for a password, and can only be used with the Administrator password. Also, when a
User password is defined, it suppresses the USB Reordering that occurs, if enabled, when a
new USB boot device is attached to the system. A User is restricted from booting in anything
other than the Boot Order defined in the Setup by an Administrator.
As a security measure, if a User or Administrator enters an incorrect password three times in a
row during the boot sequence, the system is placed into a halt state. A system reset is required
to exit out of the halt state. This feature makes it more difficult to guess or break a password.
In addition, on the next successful reboot, the Error Manager displays a Major Error code 0048,
which also logs a SEL event to alert the authorized user or administrator that a password
System Security Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
84 Intel order number G34153-003 Revision 1.2
access failure has occurred.
5.2 Trusted Platform Module (TPM) Support
The Trusted Platform Module (TPM) option is a hardware-based security device that addresses
the growing concern on boot process integrity and offers better data protection. TPM protects
the system start-up process by ensuring it is tamper-free before releasing system control to the
operating system. A TPM device provides secured storage to store data, such as security keys
and passwords. In addition, a TPM device has encryption and hash functions. The server board
implements TPM as per TPM PC Client Specifications revision 1.2 by the Trusted Computing
Group (TCG).
A TPM device is optionally installed onto a high density 14-pin connector labeled “TPM” on the
server board, and is secured from external software attacks and physical theft. A pre-boot
environment, such as the BIOS and operating system loader, uses the TPM to collect and store
unique measurements from multiple factors within the boot process to create a system
fingerprint. This unique fingerprint remains the same unless the pre-boot environment is
tampered with. Therefore, it is used to compare to future measurements to verify the integrity of
the boot process.
After the system BIOS completes the measurement of its boot process, it hands off control to
the operating system loader and in turn to the operating system. If the operating system is
TPMenabled, it compares the BIOS TPM measurements to those of previous boots to make
sure the
system was not tampered with before continuing the operating system boot process. Once the
operating system is in operation, it optionally uses TPM to provide additional system and data
security (for example, Microsoft Vista* supports Bitlocker drive encryption).
5.2.1 TPM security BIOS
The BIOS TPM support conforms to the TPM PC Client Implementation Specification for
Conventional BIOS and to the TPM Interface Specification, and the Microsoft Windows
BitLocker* Requirements. The role of the BIOS for TPM security includes the following:
Measures and stores the boot process in the TPM microcontroller to allow a TPM
enabled operating system to verify system boot integrity.
Produces EFI and legacy interfaces to a TPM-enabled operating system for using TPM.
Produces ACPI TPM device and methods to allow a TPM-enabled operating system to
send TPM administrative command requests to the BIOS.
Verifies operator physical presence. Confirms and executes operating system TPM
administrative command requests.
Provides BIOS Setup options to change TPM security states and to clear TPM
ownership.
For additional details, refer to the TCG PC Client Specific Implementation Specification, the
TCG PC Client Specific Physical Presence Interface Specification, and the Microsoft BitLocker*
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS System Security
Revision 1.2 Intel order number G34153-003 85
Requirement documents.
5.2.2 Physical Presence
Administrative operations to the TPM require TPM ownership or physical presence indication by
the operator to confirm the execution of administrative operations. The BIOS implements the
operator presence indication by verifying the setup Administrator password.
A TPM administrative sequence invoked from the operating system proceeds as follows:
1. User makes a TPM administrative request through the operating system’s security software.
2. The operating system requests the BIOS to execute the TPM administrative command through TPM
ACPI methods and then resets the system.
3. The BIOS verifies the physical presence and confirms the command with the operator.
4. The BIOS executes TPM administrative command(s), inhibits BIOS Setup entry and boots
directly to the operating system which requested the TPM command(s).
5.2.3 TPM Security Setup Options
The BIOS TPM Setup allows the operator to view the current TPM state and to carry out
rudimentary TPM administrative operations. Performing TPM administrative options through the
BIOS setup requires TPM physical presence verification.
Using BIOS TPM Setup, the operator can turn ON or OFF TPM functionality and clear the TPM
ownership contents. After the requested TPM BIOS Setup operation is carried out, the option
reverts to No Operation.
The BIOS TPM Setup also displays the current state of the TPM, whether TPM is enabled or
disabled and activated or deactivated. Note that while using TPM, a TPM-enabled operating
system or application may change the TPM state independent of the BIOS setup. When an
operating system modifies the TPM state, the BIOS Setup displays the updated TPM state.
The BIOS Setup TPM Clear option allows the operator to clear the TPM ownership key and
allows the operator to take control of the system with TPM. You use this option to clear security
settings for a newly initialized system or to clear a system for which the TPM ownership security
key was lost.
5.2.3.1 Security Screen
To enter the BIOS Setup, press the F2 function key during boot time when the OEM or Intel logo
displays. The following message displays on the diagnostics screen and under the Quiet Boot
logo screen:
Press <F2> to enter setup
When the Setup is entered, the Main screen displays. The BIOS Setup utility provides the
Security screen to enable and set the user and administrative passwords and to lock out the
front panel buttons so they cannot be used. The Intel® Server Board S5520URT provides TPM
settings through the security screen.
To access this screen from the Main screen, select the Security option.
System Security Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
86 Intel order number G34153-003 Revision 1.2
Main Advanced
Main
Advanced
Security
Server Management
Boot Options
Boot Manager
Administrator Password Status
<Installed/Not Installed>
User Password Status
<Installed/Not Installed>
Set Administrator Password
[1234aBcD]
Set User Password
[1234aBcD]
Front Panel Lockout
Enabled/Disabled
TPM State
<Enabled & Activated/Enabled & Deactivated/Disabled &
Activated/Disabled & Deactivated>
TPM Administrative Control
No Operation/Turn On/Turn Off/Clear Ownership
Figure 26. Setup Utility TPM Configuration Screen
Table 28. TSetup Utility Security Configuration Screen Fields
Setup Item
Options
Help Text
Comments
TPM State*
Enabled and
Activated
Enabled and
Deactivated
Disabled and
Activated
Disabled and
Deactivated
Information only.
Shows the current TPM device
state.
A disabled TPM device will not
execute commands that use TPM
functions and TPM security
operations will not be available.
An enabled and deactivated TPM
is in the same state as a disabled
TPM except setting of TPM
ownership is allowed if not
present already.
An enabled and activated TPM
executes all commands that use
TPM functions and TPM security
operations will be available.
TPM
Administrative
Control**
No Operation
Turn On
Turn Off
Clear Ownership
[No Operation] - No changes to
current state.
[Turn On] - Enables and activates
TPM.
[Turn Off] - Disables and deactivates
TPM.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS System Security
Revision 1.2 Intel order number G34153-003 87
Setup Item
Options
Help Text
Comments
[Clear Ownership] - Removes the
TPM ownership authentication and
returns the TPM to a factory default
state.
Note: The BIOS setting returns to
[No Operation] on every boot cycle
by default.
5.3 Intel®
Trusted Execution Technology
The Intel® Xeon® Processor E5-4600/2600/2400/1600 Product Families support Intel® Trusted
Execution Technology (Intel® TXT), which is a robust security environment. Designed to help
protect against software-based attacks, Intel® Trusted Execution Technology integrates new
security features and capabilities into the processor, chipset and other platform components.
When used in conjunction with Intel® Virtualization Technology, Intel® Trusted Execution
Technology provides hardware-rooted trust for your virtual applications.
This hardware-rooted security provides a general-purpose, safer computing environment
capable of running a wide variety of operating systems and applications to increase the
confidentiality and integrity of sensitive information without compromising the usability of the
platform.
Intel® Trusted Execution Technology requires a computer system with Intel® Virtualization
Technology enabled (both VT-x and VT-d), an Intel® Trusted Execution Technology-enabled
processor, chipset and BIOS, Authenticated Code Modules, and an Intel® Trusted Execution
Technology compatible measured launched environment (MLE). The MLE could consist of a
virtual machine monitor, an OS or an application. In addition, Intel® Trusted Execution
Technology requires the system to include a TPM v1.2, as defined by the Trusted Computing
Group TPM PC Client specifications, Revision 1.2.
When available, Intel Trusted Execution Technology can be enabled or disabled in the
processor by a BIOS Setup option.
For general information about Intel® TXT, visit the Intel® Trusted Execution Technology website,
http://www.intel.com/technology/security/.
Connector/Header Locations and Pin-outs Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
88 Intel order number G34153-003 Revision 1.2
6. Connector/Header Locations and Pin-outs
6.1 Power Connectors
6.1.1 Main Power Connector
Main server board power is supplied by one 12-pin power connector. The connector is labeled as “MAIN
PWR” on the left bottom of the server board. The following tables provide the pin-out for “MAIN PWR”
connector.
Table 29. Main Power Connector Pin-out
Pin
Signal name
Pin
Signal name
1
P3V3
13
P3V3
2
P3V3
14
N12V
3
GND
15
GND
4
P5V
16
FM_PS_EN_PSU_N
5
GND
17
GND
6
P5V
18
GND
7
GND
19
GND
8
PWRGD_PS_PWROK_PSU_R1
20
NC_PS_RES_TP
9
P5V_STBY_PSU
21
P5V
10
P12V
22
P5V
11
P12V
23
P5V
12
P3V3
24
GND
6.1.2 CPU Power Connectors
On the server board are two white 8-pin CPU power connectors labeled “CPU_1 PWR” and “CPU_2
PWR”. The following table provides the pin-out for both connectors.
Table 30. CPU_1 Power Connector Pin-out
Pin
Signal name
Pin
Signal name
1
GND
5
P12V1
2
GND
6
P12V1
3
GND
7
P12V3A
4
GND
8
P12V3A
Table 31. CPU_2 Power Connector Pin-out
Pin
Signal name
Pin
Signal name
1
GND
5
P12V2
2
GND
6
P12V2
3
GND
7
P12V3B
4
GND
8
P12V3B
6.1.3 Add-in Card Power Connectors
The serve board includes white 2x2-pin power connectors that provide supplemental power to
high power PCIe x16 add-in cards (Video or GPGPU) that have power requirements that
exceed the maximum power supplied by the riser slot. A cable from this connector may be
routed to a matching connector on a riser card designed to support it or directly to the add-in
cards that need them. Available power to each of these connectors is limited by the amount of
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Connector/Header Locations and Pin-outs
Revision 1.2 Intel order number G34153-003 89
power provided by the power supply and the total power draw for the rest of the system. A
power budget for the complete system should be performed to determine how much
supplemental power is available to support any high power add-in cards.
Each connector is labeled as “OPT_12V_PWR” on the server board. The following table
provides the pin-out for both connectors.
Table 32. Add-in Slot Power Pin-input ("OPT_12V_PWR")
Pin
Signal Name
Pin
Signal Name
1
GND
3
+12V
2
GND
4
+12V
6.2 Front Panel Header and Connectors
The server board includes several connectors that provide various possible front panel options. This
section provides a functional description and pin-out for each connector.
6.2.1 Front Panel Header
Included on the left edge of the server board is a 30-pin header consists of a 24-pin SSI
compatible front panel header and a 4-pin header to support optional NIC3/4 LEDs. The 24-pin
SSI front panel header provides various front panel features including:
Power/Sleep Button
System ID Button
NMI Button
NIC Activity LEDs
Hard Drive Activity LEDs
System Status LED
System ID LED
The following table provides the pin-out for this 30-pin header.
Table 33. Front Panel Header Pin-out
Pin
Signal name
Pin
Signal name
1
P3V3_AUX
2
P3V3_AUX
3
Key
4
P5V_STBY
5
FP_PWR_LED_BUF_N
6
FP_ID_LED_BUF_N
7
P3V3
8
FP_LED_STATUS_GREEN_BUF_N
9
LED_HDD_ACTIVITY_N
10
FP_LED_STATUS_AMBER_BUF_N
11
FP_PWR_BTN_N
12
LED_NIC_LINK0_ACT_BUF_N
13
GND
14
LED_NIC_LINK0_LNKUP_BUF_N
15
FP_RST_BTN_N
16
SMB_SENSOR_3V3STBY_DATA
17
GND
18
SMB_SENSOR_3V3STBY_CLK
19
FP_ID_BTN_N
20
FP_CHASSIS_INTRUSION
21
PU_FM_SIO_TEMP_SENSOR
22
LED_NIC_LINK1_ACT_BUF_N
23
FP_NMI_BTN_N
24
LED_NIC_LINK1_LNKUP_BUF_N
25
<Empty Pin>
26
<Empty Pin>
27
LED_NIC_LINK2_ACT_FP_N
28
LED_NIC_LINK3_ACT_FP_N
29
LED_NIC_LINK2_LNKUP_FP_N
30
LED_NIC_LINK3_LNKUP_FP_N
Connector/Header Locations and Pin-outs Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
90 Intel order number G34153-003 Revision 1.2
6.2.2 Front Panel USB Connector
The server board includes a 10-pin connector, that when cabled, can provide up to two USB
ports to a front panel. The following table provides the connector pin-out.
Table 34. Front Panel USB Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
P5V_USB_FP
2
P5V_USB_FP
3
USB2_P13_F_DN
4
USB2_P11_F_DN
5
USB2_P13_F_DP
6
USB2_P11_F_DP
7
GND
8
GND
9
KEY
10
NA
6.2.3 Local Control Panel Connector
The server board includes a 7-pin connector that is used when the system is configured with the
Intel Local Control Panel with LCD support. The following table provides the pin-out for this
connector.
Table 35. Local Front Panel Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
SMB_SENSOR_3V3STBY_DATA
2
GND
3
SMB_SENSOR_3V3STBY_CLK
4
P3V3_AUX
5
FM_LCP_ENTER_N
6
FM_LCP_LEFT_N
7
FM_LCP_RIGHT_N
6.3 On Board Storage Connectors
The server board provides connectors for support of several storage device options. This
section provides a functional overview and pin-out of each connector.
6.3.1 SATA Connectors: 6Gbps
The board includes two white single port SATA only connectors capable of transfer rates of up
to 6Gb/s. The following table provides the pin-out for both connectors.
Table 36. SATA 6Gbps Connector Pin-out
Pin
Signal Name
1
GND
2
SATA_TX_P
3
SATA_TX_N
4
GND
5
SATA_RX_N
6
SATA_RX_P
7
GND
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Connector/Header Locations and Pin-outs
Revision 1.2 Intel order number G34153-003 91
6.3.2 Multiport Mini-SAS/SATA Connectors
The board includes two 40-pin high density multiport mini-SAS/SATA connectors. On the board,
these connectors are labeled as “SCU0 port(0-3)” supporting the chipset embedded SCU0
controller, and “SCU1 Port(4-7)”, supporting the embedded SCU1 controller. Both connectors
can support up to four SATA or SAS ports each. By default, only the connector labeled “SCU0
Port(0-3)” is enabled and has support for up to four SATA ports capable. The connector labeled
“SCU1 Port(4-7)” is only enabled when an optional 8-port SAS or SATA Intel® RAID C600
Upgrade Key is installed. The following tables provide the pin-out for each connector.
Table 37. Multiport SAS/SATA Connector Pin-out ("SCU_0 (0-3)")
Pin
Signal name
Pin
Signal name
A1
GROUND
B1
GROUND
A2
SAS0_RX_C_DP
B2
SAS0_TX_C_DP
A3
SAS0_RX_C_DN
B3
SAS0_TX_C_DN
A4
GROUND
B4
GROUND
A5
SAS1_RX_C_DP
B5
SAS1_TX_C_DP
A6
SAS1_RX_C_DN
B6
SAS1_TX_C_DN
A7
GROUND
B7
GROUND
A8
TP_SAS1_BACKPLANE_TYPE
B8
SGPIO_SAS1_CLOCK
A9
GROUND
B9
SGPIO_SAS1_LOAD
A10
SGPIO_SAS1_DATAOUT
B10
GROUND
A11
SGPIO_SAS1_DATAIN
B11
PD_SAS1_CONTROLLER_TYPE
A12
GROUND
B12
GROUND
A13
SAS2_RX_C_DP
B13
SAS2_TX_C_DP
A14
SAS2_RX_C_DN
B14
SAS2_TX_C_DN
A15
GROUND
B15
GROUND
A16
SAS3_RX_C_DP
B16
SAS3_TX_C_DP
A17
SAS3_RX_C_DN
B17
SAS3_TX_C_DN
A18
GROUND
B18
GROUND
MTH1
GROUND
MTH5
GROUND
MTH2
GROUND
MTH6
GROUND
MTH3
GROUND
MTH7
GROUND
MTH4
GROUND
MTH8
GROUND
Table 38. Multiport SAS/SATA Connector Pin-out ("SCU_1 (4-7)")
Pin
Signal name
Pin
Signal name
A1
GROUND
B1
GROUND
A2
SAS4_RX_C_DP
B2
SAS4_TX_C_DP
A3
SAS4_RX_C_DN
B3
SAS4_TX_C_DN
A4
GROUND
B4
GROUND
A5
SAS5_RX_C_DP
B5
SAS5_TX_C_DP
A6
SAS5_RX_C_DN
B6
SAS5_TX_C_DN
A7
GROUND
B7
GROUND
A8
TP_SAS2_BACKPLANE_TYPE
B8
SGPIO_SAS2_CLOCK
A9
GROUND
B9
SGPIO_SAS2_LOAD
A10
SGPIO_SAS2_DATAOUT
B10
GROUND
A11
SGPIO_SAS2_DATAIN
B11
PD_SAS2_CONTROLLER_TYPE
A12
GROUND
B12
GROUND
A13
SAS6_RX_C_DP
B13
SAS6_TX_C_DP
Connector/Header Locations and Pin-outs Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
92 Intel order number G34153-003 Revision 1.2
Pin
Signal name
Pin
Signal name
A14
SAS6_RX_C_DN
B14
SAS6_TX_C_DN
A15
GROUND
B15
GROUND
A16
SAS7_RX_C_DP
B16
SAS7_TX_C_DP
A17
SAS7_RX_C_DN
B17
SAS7_TX_C_DN
A18
GROUND
B18
GROUND
MTH1
GROUND
MTH5
GROUND
MTH2
GROUND
MTH6
GROUND
MTH3
GROUND
MTH7
GROUND
MTH4
GROUND
MTH8
GROUND
6.3.3 Intel®
RAID C600 Upgrade Key Connector
The server board provides one connector to support Intel® RAID C600 Upgrade Key. The Intel® RAID
C600 Upgrade Key is a small PCB board that enables different versions of RAID 5 software stack and/or
upgrade from SATA to SAS storage functionality. The pin configuration of connector is identical and
defined in the following table.
Table 39. Intel® RAID C600 Upgrade Key Connector Pin-out
Pin
Signal Name
1
GND
2
FM_PBG_DYN_SKU_KEY
3
GND
4
FM_SSB_SAS_SATA_RAID_KEY
6.3.4 HSBP_I2C Header
Table 40. HSBP_I2C Header Pin-out
Pin
Signal Name
1
SMB_HSBP_3V3STBY_DATA
2
GND
3
SMB_HSBP_3V3STBY_CLK
6.3.5 HDD LED Header
The server board includes a 2-pin hard drive activity LED header used with some SAS/SATA controller
add-in cards. The header has the following pin-out.
Table 41. HDD LED Header Pin-out
Pin
Signal Name
Pin
Signal Name
1
LED_HDD_ACT_N
2
NA
6.3.6 Internal Type- A USB Connector
The server board includes two internal Type-A USB connector. The following table provides the
pin-out for this connector.
Table 42. Type-A USB Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
P5V
2
USB2_P2_F_DN
3
USB2_P2_F_DP
4
GND
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Connector/Header Locations and Pin-outs
Revision 1.2 Intel order number G34153-003 93
6.3.7 Internal eUSB SSD Header
The server board includes one 10-pin internal eUSB header with an intended usage of supporting USB
SSD devices. The following table provides the pin-out for this connector.
Table 43. eUSB SSD Header Pin-out
Pin
Signal Name
Pin
Signal Name
1
5V
2
NC
3
USB2_P0_DN
4
NC
5
USB2_P0_DP
6
NC
7
GND
8
NC
9
Key
10
LED_HDD_ACT_ZEPHER_N
6.4 Management and Security Connectors
6.4.1 RMM4_Lite Connector
A 7-pin Intel® RMM4 Lite connector is included on the server board to support the optional Intel® Remote
Management Module 4. There is no support for third-party management cards on this server board.
Table 44. RMM4_Lite Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
P3V3_AUX
2
DI
3
KEY
4
CLK
5
DO
6
GND
7
CS_N
8
GND
6.4.2 RMM4_NIC Connector
Table 45. RMM4_NIC Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
3V3_AUX
2
MDIO
3
3V3_AUX
4
MDC
5
GND
6
TXD_0
7
GND
8
TXD_1
9
GND
10
TXD_2
11
GND
12
TXD_3
13
GND
14
TX_CTL
15
GND
16
RX_CTL
17
GND
18
RXD_0
19
GND
20
RXD_1
21
GND
22
RXD_2
23
GND
24
RXD_3
25
GND
26
TX_CLK
27
GND
28
RX_CLK
29
GND
30
PRESENT#
Connector/Header Locations and Pin-outs Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
94 Intel order number G34153-003 Revision 1.2
6.4.3 TPM Connector
Table 46. TPM Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
Key
2
LPC_LAD<1>
3
LPC_LAD<0>
4
GND
5
IRQ_SERIAL
6
LPC_FRAME_N
7
P3V3
8
GND
9
RST_IBMC_NIC_N_R2
10
CLK_33M_TPM
11
LPC_LAD<3>
12
GND
13
GND
14
LPC_LAD<2>
6.4.4 PMBus* Connector
Table 47. PMBus* Connector Pin-out
Pin
Signal name
1
SMB_PMBUS_CLK_R
2
SMB_PMBUS_DATA_R
3
IRQ_SML1_PMBUS_ALERT_RC_N
4
GND
5
P3V3
6.4.5 Chassis Intrusion Header
The server board includes a 2-pin chassis intrusion header which can be used when the chassis
is configured with a chassis intrusion switch. The header has the following pin-out.
Table 48. Chassis Intrusion Header Pin-out
Header State
Description
Pins 1 and 2 closed
FM_INTRUDER_HDR_N is pulled HIGH. Chassis cover is closed.
Pins 1 and 2 open
FM_INTRUDER_HDR_N is pulled LOW. Chassis cover is removed.
6.4.6 IPMB Connector
Table 49. IPMB Connector Pin-out
Pin
Signal Name
1
SMB_IPMB_5VSTBY_DATA
2
GND
3
SMB_IPMB_5VSTBY_CLK
4
P5V_STBY
6.5 FAN Connectors
The server board provides support for nine fans. Seven of them are system cooling fans, two of
them are CPU fans.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Connector/Header Locations and Pin-outs
Revision 1.2 Intel order number G34153-003 95
6.5.1 System FAN Connectors
The six system cooling fan connectors near the front edge of the board are 6-Pin connectors;
the one system cooling fan near edge of the board is a 4-Pin connectors. Following table
provides the pin-out for all system fan connectors.
Table 50. 6-pin System FAN Connector Pin-out
Pin
Signal Name
1
GND
2
12V
3
TACH
4
PWM
5
PRSNT
6
FAULT
Table 51. 4-pin System FAN Connector Pin-out
Pin
Signal Name
1
GND
2
12V
3
TACH
4
PWM
6.5.2 CPU FAN Connector
The two CPU fan connectors are 4-pin fan connectors. Following table provides the pin-out for
CPU fan connectors.
Table 52. CPU FAN Connector Pin-out
Pin
Signal Name
1
GND
2
12V
3
TACH
4
PWM
6.6 Serial Port and Video Connectors
The server board includes two serial port connectors.
6.6.1 Serial Port A Connector (DB9, for Intel® Server Board S2600IP only)
Serial-A is an external RJ45 type connector and has the following pin-out configuration.
Table 53. Serial Port A Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
SPA_DCD
2
SPA_SIN
3
SPA_SOUT_N
4
SPA_DTR
5
GND
6
SPA_DSR
7
SPA_RTS
8
SPA_CTS
9
SPA_RI
Connector/Header Locations and Pin-outs Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
96 Intel order number G34153-003 Revision 1.2
6.6.2 Serial Port B Connector
Serial-B is an internal 10-pin DH-10 connector and has the following pin-out.
Table 54. Serial Port B Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
SPA_DCD
2
SPA_DSR
3
SPA_SIN
4
SPA_RTS
5
SPA_SOUT_N
6
SPA_CTS
7
SPA_DTR
8
SPA_RI
9
GND
6.6.3 Video Connector (For Intel® Server Board S2600IP only)
The following table details the pin-out definition of the external VGA connector.
Table 55. Video Connector Pin-out details
Figure 27. Video Connector Pin-out
Pin
Signal Name
1
CRT_RED
2
CRT_GREEN
3
CRT_BLUE
4
N/C
5
GND
6
GND
7
GND
8
GND
9
P5V
10
GND
11
NC
12
CRT_DDCDATA
13
CRT_HSYNC
14
CRT_VSYNC
15
CRT_DDCCLK
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Connector/Header Locations and Pin-outs
Revision 1.2 Intel order number G34153-003 97
6.6.4 Internal Video header (For Intel® Workstation Board W2600CR only)
Pin
Signal Name
1
CRT_RED
2
GND
3
CRT_Green
4
GND
5
CRT_Blue
6
GND
7
CRT_VSYNC
8
GND
9
CRT_HSYN
10
Key
11
CRT_DDCDATA
12
VIDEO_IN_USE signal
13
CRT_DDCCLK
14
5V
Note: Intel® Corporation server boards support peripheral components and can contain a
number of high-density VLSI and power delivery components that need adequate airflow to cool.
Intel’s own chassis are designed and tested to meet the intended thermal requirements of these
components when the fully integrated system is used together. It is the responsibility of the
system integrator that chooses not to use Intel® developed server building blocks to consult
vendor datasheets and operating parameters to determine the amount of airflow required for
their specific application and environmental conditions. Intel Corporation cannot be held
responsible if components fail or the server board does not operate correctly when used outside
any of its published operating or non-operating limits.
Jumper Blocks Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
98 Intel order number G34153-003 Revision 1.2
7. Jumper Blocks
The server boards have several 3-pin jumper blocks that you can use to configure, protect, or recover
specific features of the server boards.
The following symbol identifies Pin 1 on each jumper block on the silkscreen:
Figure 28. Jumper Blocks (J1C3, J1F1, J1F2, J2F3, J2F2)
Table 56. Server Board Jumpers (J1C3, J1F1, J1F2, J2F3, J2F2)
Jumper Name
Pins
System Results
J1F2: BIOS Recovery
1-2
Pins 1-2 should be connected for normal system operation. (Default)
2-3
The main system BIOS does not boot with pins 2-3 connected. The system only
boots from EFI-bootable recovery media with a recovery BIOS image present.
J1F1: Bios Default
(CMOS Clear)
1-2
These pins should have a jumper in place for normal system operation.
(Default)
2-3
If pins 2-3 are connected when AC power unplugged, the CMOS settings clear
in 5 seconds. Pins 2-3 should not be connected for normal system operation.
J2F2: ME Force
1-2
ME Firmware Force Update Mode Disabled (Default)
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Jumper Blocks
Revision 1.2 Intel order number G34153-003 99
Jumper Name
Pins
System Results
Update
2-3
ME Firmware Force Update Mode Enabled
J1C1: BMC Force
Update
1-2
BMC Firmware Force Update Mode Disabled (Default)
2-3
BMC Firmware Force Update Mode Enabled
J2F3: Password Clear
1-2
These pins should have a jumper in place for normal system operation.
(Default)
2-3
To clear administrator and user passwords, power on the system with pins 2-3
connected. The administrator and user passwords clear in 5-10 seconds after
power on. Pins 2-3 should not be connected for normal system operation.
7.1 BIOS Default and Password Reset Usage Procedure
The BIOS Default (CMOS Clear) and Password Reset recovery features are designed to
achieve the desired operation with minimum system down time. The usage procedure for these
two features has changed from previous generation Intel® boards. The following procedure
outlines the new usage model.
7.1.1 Set BIOS to default (Clearing the CMOS)
1. Power down the server and unplug the AC power cord.
2. Open the server chassis. For instructions, see your server chassis documentation.
3. Move the jumper from the default operating position (covering pins 1 and 2) to the reset/clear
position (covering pins 2 and 3).
4. Wait five seconds.
5. Move the jumper back to the default position, covering pins 1 and 2.
6. Close the server chassis and reconnect the AC power cord.
7. Power up the server.
The CMOS is now cleared and you can reset it by going into the BIOS setup.
Note: Removing AC power before performing the CMOS clear operation causes the system to
automatically power up and immediately power down, after the procedure is followed and AC
power is re-applied. If this happens, remove the AC power cord again, wait 30 seconds, and
reinstall the AC power cord. Power up the system and proceed to the <F2> BIOS Setup utility to
reset the preferred settings.
7.1.2 Clearing the Password
1. Power down the server. Do not unplug the power cord.
2. Open the chassis. For instructions, see your server chassis documentation.
3. Move the jumper from the default operating position (covering pins 1 and 2) to the password clear
position (covering pins 2 and 3).
4. Close the server chassis.
5. Power up the server and then press <F2> to enter the BIOS menu to check if the password is
cleared.
6. Power down the server.
Jumper Blocks Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
100 Intel order number G34153-003 Revision 1.2
7. Open the chassis and move the jumper back to its default position (covering pins 1 and 2).
8. Close the server chassis.
9. Power up the server.
The password is now cleared and you can reset it by going into the BIOS setup.
7.2 Force BMC Update Procedure
When performing a standard BMC firmware update procedure, the update utility places the
BMC into an update mode, allowing the firmware to load safely onto the flash device. In the
unlikely event the BMC firmware update process fails due to the BMC not being in the proper
update state, the server boards provide a Force BMC Update jumper that forces the BMC into
the proper update state. In the event the standard BMC firmware update process fails, complete
the following procedure:
1. Power down and remove the AC power cord.
2. Open the server chassis. See your server chassis documentation for instructions.
3. Move the jumper from the default operating position (covering pins 1 and 2) to the enabled
position (covering pins 2 and 3).
4. Close the server chassis.
5. Reconnect the AC power cord and power up the server.
6. Perform the BMC firmware update procedure as documented in the BMC firmware update
package. After successful completion of the firmware update process, the firmware update utility
may generate an error stating the BMC is still in update mode.
7. Power down and remove the AC power cord.
8. Open the server chassis.
9. Move the jumper from the enabled position (covering pins 2 and 3) to the disabled position
(covering pins 1 and 2).
10. Close the server chassis.
11. Reconnect the AC power cord and power up the server.
Note: When the Force BMC Update jumper is set to the enabled position, normal BMC
functionality is disabled. You should never run the server with the Force BMC Update jumper
set in this position. You should only use this jumper setting when the standard firmware update
process fails. When the server is running normally, this jumper must remain in the
default/disabled position.
7.3 BIOS Recovery Jumper
The following procedure boots the recovery BIOS and flashes the normal BIOS:
1. Turn off the system power.
2. Move the BIOS recovery jumper to the recovery state.
3. Insert a bootable BIOS recovery media containing the new BIOS image files.
4. Turn on the system power.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Jumper Blocks
Revision 1.2 Intel order number G34153-003 101
The BIOS POST screen will appear displaying the progress, and the system will boot to the EFI shell.
The EFI shell then executes the Startup.nsh batch file to start the flash update process. The user
should then switch off the power and return the recovery jumper to its normal position. The user
should not interrupt the BIOS POST on the first boot after recovery.
When the flash update completes:
1. Remove the recovery media.
2. Turn off the system power.
3. Restore the jumper to its original position.
4. Turn on the system power.
5. Re-flash any custom blocks, such as user binary or language blocks.
The system should now boot using the updated system BIOS.
7.4 ME Force Update Jumper
When performing the standard ME force update procedure, the update utility places the ME into an
update mode, allowing the ME to load safely onto the flash device. In the unlikely event ME firmware
update process fails due to ME not being in the proper update state, the server board provides an
Integrated BMC Force Update jumper, which forces the ME into the proper update state. The
following procedure should be completed in the event the standard ME firmware update process fails.
1. Power down and remove the AC power cord.
2. Open the server chassis. For instructions, see your server chassis documentation.
3. Move jumper from the default operating position (covering pins 1 and 2) to the enabled position
(covering pins 2 and 3).
4. Close the server chassis.
5. Reconnect the AC cord and power up the server.
6. Perform the ME firmware update procedure as documented in the README.TXT file that is
included in the given ME firmware update package (same package as BIOS).
7. Power down and remove the AC power cord.
8. Open the server chassis.
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering
pins 1 and 2).
10. Close the server chassis.
11. Reconnect the AC cord and power up the server.
Intel® Light Guided Diagnostics Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
102 Intel order number G34153-003 Revision 1.2
8. Intel®
Light Guided Diagnostics
Both server boards have several onboard diagnostic LEDs to assist in troubleshooting board-level issues.
This section provides a description of the location and function of each LED on the server boards.
8.1 5-volt Stand-by LED
Several server management features of these server boards require a 5-V stand-by voltage supplied from
the power supply. The features and components that require this voltage must be present when the
system is “power-down. The LED is illuminated when AC power is applied to the platform and 5-V stand-
by voltage is supplied to the server board by the power supply.
8.2 Fan Fault LED
Fan fault LEDs are present for the two CPU fans and the one rear system fan. The fan fault LEDs
illuminate when the corresponding fan has fault.
8.3 CPU Fault LED
CPU fault LED should correspond to the socket with the failed or disabled CPU. The CPU LEDs
illuminate when CPU failure or Disable.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Intel® Light Guided Diagnostics
Revision 1.2 Intel order number G34153-003 103
Figure 29. Stand by LED, Fan Fault LED and CPU Fault LED Location
Intel® Light Guided Diagnostics Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
104 Intel order number G34153-003 Revision 1.2
8.4 DIMM Fault LEDs
The server board provide memory fault LED for each DIMM socket. These LEDs are located as shown in
the following figure. The DIMM fault LED illuminates when the corresponding DIMM slot has memory
installed and a memory error occurs.
Figure 30. DIMM Fault LED’s Location
8.5 System ID LED, System Status LED and POST Code Diagnostic LEDs
The server boards provide LEDs for system ID, system status and POST code. These LEDs are located
in the rear I/O area of the server board as shown in the following figure.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Intel® Light Guided Diagnostics
Revision 1.2 Intel order number G34153-003 105
Figure 31. Location of System Status, System ID and POST Code Diagnostic LEDs
LED Name
Description
A
System Status LED
B
System ID LED
LSB 1 2 3 4 5 6 MSB
Post Code Diagnostic LEDs
8.5.1 System ID LED
You can illuminate the blue System ID LED using either of the following two mechanisms:
By pressing the System ID Button on the system front control panel, the ID LED displays a solid
blue color until the button is pressed again.
By issuing the appropriate hex IPMI “Chassis Identify” value, the ID LED will either blink blue for
15 seconds and turn off or will blink indefinitely until the appropriate hex IPMI Chassis Identify
value is issue to turn it off.
Intel® Light Guided Diagnostics Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
106 Intel order number G34153-003 Revision 1.2
8.5.2 System Status LED
The bi-color (green/amber) System Status LED operates as follows:
Table 57. System Status LED
Color
State
Criticality
Description
Green
Solid on
Ok
Indicates that the System Status is ‘Healthy’. The system is not exhibiting any
errors. AC power is present and BMC has booted and manageability
functionality is up and running.
Green
~1 Hz blink
Degraded
System degraded:
1. Redundancy loss such as power-supply or fan. Applies only if the
associated platform sub-system has redundancy capabilities.
2. Fan warning or failure when the number of fully operational fans is more
than minimum number needed to cool the system.
3. Non-critical threshold crossed Temperature (including HSBP temp),
voltage, input power to power supply, output current for main power rail
from power supply and Processor Thermal Control (Therm Ctrl) sensors.
4. Power supply predictive failure occurred while redundant power supply
configuration was present.
5. Unable to use all of the installed memory (more than 1 DIMM installed).
6. Correctable Errors over a threshold and migrating to a spare DIMM
(memory sparing). This indicates that the user no longer has spared
DIMMs indicating a redundancy lost condition. Corresponding DIMM LED
lit.
7. In mirrored configuration, when memory mirroring takes place and system
loses memory redundancy.
8. Battery failure.
9. BMC executing in uBoot. (Indicated by Chassis ID blinking at Blinking at
3Hz). System in degraded state (no manageability). BMC uBoot is running
but has not transferred control to BMC Linux. Server will be in this state 6-
8 seconds after BMC reset while it pulls the Linux image into flash
10. BMC booting Linux. (Indicated by Chassis ID solid ON). System in
degraded state (no manageability). Control has been passed from BMC
uBoot to BMC Linux itself. It will be in this state for ~10-~20 seconds.
11. BMC Watchdog has reset the BMC.
12. Power Unit sensor offset for configuration error is asserted.
13. HDD HSC is off-line or degraded.
Amber
~1 Hz blink
Non-critical
Non-fatal alarm system is likely to fail:
1. Critical threshold crossed Voltage, temperature (including HSBP temp),
input power to power supply, output current for main power rail from
power supply and PROCHOT (Therm Ctrl) sensors.
2. VRD Hot asserted.
3. Minimum number of fans to cool the system not present or failed
4. Hard drive fault
5. Power Unit Redundancy sensor Insufficient resources offset (indicates
not enough power supplies present).
6. In non-sparing and non-mirroring mode if the threshold of correctable
errors is crossed within the window
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Intel® Light Guided Diagnostics
Revision 1.2 Intel order number G34153-003 107
Color
State
Criticality
Description
Amber
Solid on
Critical, non-
recoverable
Fatal alarm system has failed or shutdown:
1. CPU CATERR signal asserted.
2. MSID mismatch detected (CATERR also asserts for this case).
3. CPU 1 is missing.
4. CPU ThermalTrip.
5. No power good power fault.
6. DIMM failure when there is only 1 DIMM present and hence no
good memory present.
7. Runtime memory uncorrectable error in non-redundant mode 1.
8. DIMM Thermal Trip or equivalent.
9. SSB Thermal Trip or equivalent.
10. CPU ERR2 signal asserted.
11. BMC/Video memory test failed. (Chassis ID shows blue/solid-on for
this condition).
12. Both uBoot BMC FW images are bad. (Chassis ID shows blue/solid on for
this condition).
13. 13. 240VA fault
Off
N/A
Not ready
AC power off
8.5.3 POST Code Diagnostic LEDs
During the system boot process, the BIOS executes a number of platform configuration processes, each
of which is assigned a specific hex POST code number. As each configuration routine is started, the
BIOS displays the given POST code to the POST code diagnostic LED’s on the back edge of the server
boards. To assist in troubleshooting a system hang during the POST process, you can use the diagnostic
LEDs to identify the last POST process executed.
Table 58. POST Code Diagnostic LEDs
A. Diagnostic LED #7 (MSB LED)
E. Diagnostic LED #3
B. Diagnostic LED #6
F. Diagnostic LED #2
C. Diagnostic LED #5
G. Diagnostic LED #1
D. Diagnostic LED #4
H. Diagnostic LED #0 (LSB LED)
Design and Environmental Specifications Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
108 Intel order number G34153-003 Revision 1.2
9. Design and Environmental Specifications
9.1 Products Design Specifications
The following table defines the Intel® Server Board S2600IP and Intel® Workstation Board W2600CR
operating and non-operating environmental limits. Operation of the Intel® Server Board S2600IP and
Intel® Workstation Board W2600CR at conditions beyond those shown in the following table may cause
permanent damage to the system. Exposure to absolute maximum rating conditions for extended periods
may affect system reliability.
Table 59. Server Board Design Specifications
Operating Temperature
C to 55º C 1 (32º F to 131º F)
Non-Operating Temperature
-40º C to 70º C (-40º F to 158º F)
DC Voltage
± 5% of all nominal voltages
Shock (Unpackaged)
Trapezoidal, 35g , 170 inches/sec
Shock (Packaged)
< 20 pounds
20 to < 40 pounds
40 to < 80 pounds
80 to < 100 pounds
100 to < 120 pounds
120 pounds
36 inches
30 inches
24 inches
18 inches
12 inches
9 inches
Vibration (Unpackaged)
5 Hz to 500 Hz 3.13 g RMS random
Note: 1. Intel Corporation server boards contain a number of high-density VLSI and power delivery components
that need adequate airflow to cool. Intel ensures through its own chassis development and testing that
when Intel® server building blocks are used together, the fully integrated system will meet the intended
thermal requirements of these components. It is the responsibility of the system integrator who
chooses not to use Intel® developed server building blocks to consult vendor datasheets and operating
parameters to determine the amount of airflow required for their specific application and environmental
conditions. Intel Corporation cannot be held responsible if components fail or the server board does not
operate correctly when used outside any of its published operating or non-operating limits.
Disclaimer Note: Intel® ensures the unpackaged server board and system meet the shock requirement
mentioned above through its own chassis development and system configuration. It is the responsibility of
the system integrator to determine the proper shock level of the board and system if the system integrator
chooses different system configuration or different chassis. Intel Corporation cannot be held responsible,
if components fail or the server board does not operate correctly when used outside any of its published
operating or non-operating limits.
9.2 MTBF
The following is the calculated Mean Time Between Failures (MTBF) 30 C (ambient air). These values
are derived using a historical failure rate and multiplied by factors for application, electrical and/or thermal
stress and for device maturity. You should view MTBF estimates as “reference numbers” only.
Calculation Model: Telcordia* Issue 2, method I case 3
Operating Temperature: Server in 30°C ambient air
Operating Environment: Ground Benign, Controlled
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Design and Environmental Specifications
Revision 1.2 Intel order number G34153-003 109
Duty Cycle: 100%
Quality Level: II
Table 60. Intel® Server Board S2600IP MTBF Estimate
Assembly Name
Failure Rate
MTBF
Mother Board
4,981.828605
200,730
Integrated Circuits
888.017556
1,126,104
Transistor_Bipolar
142.288706
7,027,965
Transistor_MOSFET
394.540757
2,534,592
Diodes
24.364143
41,043,923
Diodes_LED
30.002406
33,330,661
Resistors
1,134.467959
881,470
Capacitors
379.972284
2,631,771
Cap, Al Elect
741.486991
1,348,641
Inductors
148.990773
6,711,825
Connections
1,213.354514
824,161
Misc
94.901757
10,537,213
Table 61. Intel® Workstation Board W2600CR MTBF Estimate
Assembly Name
Failure Rate
MTBF
Mother Board
5,247.668190
190,561
Integrated Circuits
951.031471
1,051,490
Transistor_Bipolar
147.372000
6,785,549
Transistor_MOSFET
404.110588
2,474,570
Diodes
36.808324
27,167,768
Diodes_LED
30.002406
33,330,661
Resistors
1,204.023273
830,549
Capacitors
413.065171
2,420,925
Cap, Al Elect
770.924084
1,297,145
Inductors
175.282101
5,705,089
Connections
1,216.849949
821,794
Design and Environmental Specifications Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
110 Intel order number G34153-003 Revision 1.2
Assembly Name
Failure Rate
MTBF
Misc
127.585507
7,837,881
Intel® Server Board S5520HC / S5500HCV TPS Design and Environmental Specifications
Revision 1.2 Intel order number G34153-003
111
9.3 Server Board Power Requirements
This section provides power supply design guidelines for a system using the Intel® Server Board S2600IP and Workstation Board W2600CR
including voltage and current specifications, and power supply on/off sequencing characteristics. The following diagram shows the power
distribution implemented on these server boards.
Figure 32. Power Distribution Block Diagram
Appendix A: Integration and Usage Tips Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
112 Intel order number G34153-003 Revision 1.2
112
9.3.1 Processor Power Support
The server boards support the Thermal Design Power (TDP) guideline for Intel® Xeon®
processors. The Flexible Motherboard Guidelines (FMB) is followed to determine the suggested
thermal and current design values for anticipating future processor needs. The following table
provides maximum values for DTS, TDP power and TCASE for the compatible Intel® E5-2600
processor family series.
Table 62. Intel® Xeon® Processor Dual Processor TDP profile
Max TDP Power
Max Tcase (°C )
Max DTS (°C )
130W
85°C
104.4 for 6 core
100 for 8 core
150W
67°C
84.8
9.4 Power Supply Output Requirements
This section is for reference purposes only. The intent is to provide guidance to system designers to
determine a power supply to use with these server boards. This section specifies the power supply
requirements Intel used to develop a power supply for its server system.
9.4.1 Output Power/Currents
The following tables define the minimum power and current ratings. The power supply must
meet both static and dynamic voltage regulation requirements for all conditions.
Table 63. Minimum Load Ratings
Parameter
Min
Max.
Peak
Unit
3.3V
0.5
18.0
A
5V
0.3
15.0
A
12V1
0.7
24.0
28.0
A
12V2
0.7
24.0
28.0
A
12V3
1.5
18.0
A
12V
0.0
0.5
A
5Vstby
0.0
3.0
3.5
A
Notes: 1. Combined continuous power for all output shall not exceed 550W.
2. Peak combined power for all outputs shall not exceed 630W for 20 seconds.
3. Max combined power of 12V1, 12V2, and 12V3 shall not exceed 530W.
4. Max combined power on 3.3V and 5V shall not exceed 120W.
9.4.2 Cross Loading
The power supply shall maintain voltage regulation limit when operated over the following cross
loading conditions.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix A: Integration and Usage Tips
Revision 1.2 Intel order number G34153-003
113
Table 64. Loading Conditions
3.3V
5V
12V1
12V2
12V3
-12V
5Vstby
Total
Power
12V
Power
3.3V/5V
Power
Load1
18
12.1
12
12
11.7
0
0.3
550
428
120
Load2
13.5
15
12
12
11.2
0.5
0.3
549
422
120
Load3
2.5
2
20
20
4.2
0
0.3
550
530
18
Load4
2.5
2
13.1
13.1
18
0
0.3
550
530
18
Load5
0.5
0.3
15
15
6.5
0.5
3
462
438
3
Load6
16
4
1
1
3.5
0
0.3
140
66
73
Load7
16
13
1
1
9
0.5
3
271
132
118
9.4.3 Standby Output
The 5VSB output shall be present when an AC input greater than the power supply turn on
voltage is applied.
9.4.4 Voltage Regulation
The power supply output voltages must stay within the following voltage limits when operating at
steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise.
These shall be measured at the output connectors.
Table 65.Voltage Regulation Limits
Parameter
Tolerance
Min
Nom
Max
Units
+3.3V
- 3%/+5%
+3.20
+3.30
+3.46
Vrms
+5V
- 4%/+5%
+4.80
+5.00
+5.25
Vrms
+12V1
- 4%/+5%
+11.52
+12.00
+12.60
Vrms
+12V2
- 4%/+5%
+11.52
+12.00
+12.60
Vrms
+12V3
- 4%/+5%
+11.52
+12.00
+12.60
Vrms
- 12V
- 10%/+10%
- 13.20
-12.00
-10.80
Vrms
+5VSB
- 4%/+5%
+4.80
+5.00
+5.25
Vrms
9.4.5 Dynamic Loading
The output voltages shall remain within limits specified for the step loading and capacitive
loading specified in the table below. The load transient repetition rate shall be tested between
50Hz and 5kHz at duty cycles ranging from 10%-90%. The load transient repetition rate is only
a test specification. The step load may occur anywhere within the MIN load to the MAX load
conditions.
Table 66. Transient Load Requirements
Output
Step Load Size
(See note 2)
Load Slew Rate
Test capacitive Load
+3.3V
6.0A
0.5 A/sec
970 F
+5V
4.0A
0.5 A/sec
400 F
12V1+12V2+12V3
23A
0.5 A/sec
2200 F 1,2
+5VSB
0.5A
0.5 A/sec
20 F
Appendix A: Integration and Usage Tips Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
114 Intel order number G34153-003 Revision 1.2
114
Notes: 1. Step loads on each 12V output may happen simultaneously.
2. The +12V should be tested with 2200F evenly split between the four +12V rails
3. This will be tested over the range of load conditions in section 9.4.2
9.4.6 Capacitive Loading
The power supply shall be stable and meet all requirements with the following capacitive loading
ranges.
Table 67. Capacitive Loading Conditions
Output
Min
Max
Units
+3.3V
250
5000
F
+5V
400
5000
F
+12V
500
8000
F
-12V
1
350
F
+5VSB
20
350
F
9.4.7 Grounding
The output ground of the pins of the power supply provides the output power return path. The
output connector ground pins shall be connected to the safety ground (power supply enclosure).
This grounding should be well designed to ensure passing the max allowed Common Mode
Noise levels.
The power supply shall be provided with a reliable protective earth ground. All secondary
circuits shall be connected to protective earth ground. Resistance of the ground returns to
chassis shall not exceed 1.0 m. This path may be used to carry DC current.
9.4.8 Closed loop stability
The power supply shall be unconditionally stable under all line/load/transient load conditions
including capacitive load ranges specified in Section 4.6. A minimum of 45 degrees phase
margin and -10dB-gain margin is required. The power supply manufacturer shall provide proof
of the unit’s closed-loop stability with local sensing through the submission of Bode plots.
Closed-loop stability must be ensured at the maximum and minimum loads as applicable.
9.4.9 Residual Voltage Immunity in Standby mode
The power supply should be immune to any residual voltage placed on its outputs (Typically a
leakage voltage through the system from standby output) up to 500mV. There shall be no
additional heat generated, nor stressing of any internal components with this voltage applied to
any individual or all outputs simultaneously. It also should not trip the protection circuits during
turn on.
The residual voltage at the power supply outputs for no load condition shall not exceed 100mV
when AC voltage is applied and the PSON# signal is de-asserted.
9.4.10 Common Mode Noise
The Common Mode noise on any output shall not exceed 350mV pk-pk over the frequency
band of 10Hz to 20MHz. The measurement shall be made across a 100Ω resistor between each
of DC outputs, including ground at the DC power connector and chassis ground (power
subsystem enclosure). The test set-up shall use a FET probe such as Tektronix model P6046 or
equivalent.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix A: Integration and Usage Tips
Revision 1.2 Intel order number G34153-003
115
9.4.11 Soft Starting
The Power Supply shall contain control circuit which provides monotonic soft start for its outputs
without overstress of the AC line or any power supply components at any specified AC line or
load conditions.
9.4.12 Zero Load Stability Requirements
When the power subsystem operates in a no load condition, it does not need to meet the output
regulation specification, but it must operate without any tripping of over-voltage or other fault
circuitry. When the power subsystem is subsequently loaded, it must begin to regulate and
source current without fault.
9.4.13 Ripple/Noise
The maximum allowed ripple/noise output of the power supply is defined in the table below. This
is measured over a bandwidth of 10Hz to 20MHz at the power supply output connectors. A
10F tantalum capacitor in parallel with a 0.1F ceramic capacitor is placed at the point of
measurement.
Table 68. Ripples and Noise
+3.3V
+5V
+12V1,2,3
-12V
+5VSB
50mVp-p
50mVp-p
120mVp-p
200mVp-p
50mVp-p
The test set-up is shown below.
AC HOT
POWER SUPPLY
AC NEUTRAL V
OUT
RETURN
V
AC GROUND
LOAD
SCOPE
LOAD MUST BE
ISOLATED FROM
THE GROUND OF
THE POWER
SUPPLY
10uF .1uF
GENERAL NOTES:
1. LOAD THE OUTPUT WITH ITS MINIMUM
LOAD CURRENT.
2. CONNECT THE PROBES AS SHOWN.
3. REPEAT THE MEASUREMENTS WITH THE
MAXIMUM LOAD ON THE OUTPUT.
SCOPE NOTE:
USE A TEKTRONIX 7834 OSCILLOSCOPE WITH 7A13 AND
DIFFERENTIAL PROBE P6055 OR EQUIVALENT.
Figure 33. Differential Noise test setup
Note:
When performing this test, the probe clips and capacitors should be located close to the load.
9.4.14 Timing Requirements
These are the timing requirements for the power supply operation. The output voltages must
rise from 10% to within regulation limits (Tvout_rise) within 2 to 50ms, except for 5VSB - it is
allowed to rise from 1 to 25ms. The +3.3V, +5V and +12V1,+12V2 ,+12V3 output voltages
should start to rise approximately at the same time. All outputs must rise monotonically.
Each output voltage shall reach regulation within 50ms (Tvout_on) of each other during turn on of
Appendix A: Integration and Usage Tips Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
116 Intel order number G34153-003 Revision 1.2
116
the power supply. Each output voltage shall fall out of regulation within 400ms (Tvout_off) of each
other during turn off. Table 69 shows the timing requirements for the power supply being turned
on and off by the AC input, with PSON held low and the PSON signal, with the AC input applied.
All timing requirements must be met for the cross loading condition in section TBD.
Table 69. Output Voltage Timing
Item
Description
Min
Max
Units
Tvout_rise
Output voltage rise time from each main output.
2
50
ms
Output rise time for the 5Vstby output.
1
25
ms
Tvout_on
All main outputs must be within regulation of
each other within this time.
50
ms
T vout_off
All main outputs must leave regulation within
this time.
400
ms
Figure 34. Output Voltage Timing
Table 70. Turn On/Off Timing
Item
Description
MIN
MAX
UNITS
Tsb_on_delay
Delay from AC being applied to 5VSB being within
regulation.
1500
ms
T ac_on_delay
Delay from AC being applied to all output voltages
being within regulation.
2500
ms
Tvout_holdup
Time all output voltages stay within regulation
after loss of AC. Tested at 75% of maximum load.
13
ms
Tpwok_holdup
Delay from loss of AC to de-assertion of PWOK.
Tested at 75% of maximum load.
12
ms
Vout
10%
Vout
Tvout_rise
Tvout_on
Tvout_off
V1
V2
V3
V4
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix A: Integration and Usage Tips
Revision 1.2 Intel order number G34153-003
117
Item
Description
MIN
MAX
UNITS
Tpson_on_delay
Delay from PSON# active to output voltages within
regulation limits.
5
400
ms
T pson_pwok
Delay from PSON# deactivate to PWOK being de-
asserted.
50
ms
Tpwok_on
Delay from output voltages within regulation limits
to PWOK asserted at turn on.
100
500
ms
T pwok_off
Delay from PWOK de-asserted to output voltages
(3.3V, 5V, 12V, -12V) dropping out of regulation
limits.
1
ms
Tpwok_low
Duration of PWOK being in the de-asserted state
during an off/on cycle using AC or the PSON
signal.
100
ms
Tsb_vout
Delay from 5VSB being in regulation to O/Ps
being in regulation at AC turn on.
10
1000
ms
T5VSB_holdup
Time the 5VSB output voltage stays within
regulation after loss of AC.
70
ms
Figure 35. Turn On/Off Timing (Power Supply Signals)
AC Input
Vout
PWOK
5VSB
PSON
T
sb_on_delay
T
AC_on_delay
T
pwok_on
T
vout_holdup
T
pwok_holdup
T
pson_on_delay
T
sb_on_delay
T
pwok_on
T
pwok_off
T
pwok_off
T
pson_pwok
T
pwok_low
T
sb_vout
AC turn on/off cycle
PSON turn on/off cycle
T5VSB_holdup
Appendix A: Integration and Usage Tips Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
118 Intel order number G34153-003 Revision 1.2
118
Appendix A: Integration and Usage Tips
When adding or removing components or peripherals from the server board, AC power must be
removed. With AC power plugged into the server board, 5-V standby is still present even though
the server board is powered off.
This server board supports The Intel® Xeon® Processor E5-2600 product family and E5-2600 v2
product family with a Thermal Design Power (TDP) of up to and including 135 Watts (TDP of up
to 150W only for Workstation board). Previous generations of Intel® Xeon® processors are not
supported.
Processors must be installed in order. CPU 1 must be populated for operating the server board.
On the back edge of the server board are eight diagnostic LEDs that display a sequence of
amber POST codes during the boot process. If the server board hangs during POST, LEDs
display the last POST event run before the hang.
This server board only supports registered DDR3 DIMMs (RDIMMs) and unbuffered DDR3
DIMMs (UDIMMs). Mixing of RDIMMs and UDIMMs is not supported.
For the best performance, the number of DDR3 DIMMs installed should be balanced across both
processor sockets and memory channels. For example, a two-DIMM configuration performs
better than a one-DIMM configuration. In a two-DIMM configuration, DIMMs should be installed in
DIMM sockets A1 and D1.
The Intel® Remote Management Module 4 (Intel® RMM4) connector is not compatible with any
previous versions of the Intel® Remote Management Module (Product Order Code AXXRMM,
AXXRMM2, and AXXRMM3).
Clear the CMOS with AC power cord plugged. Removing the AC power before performing the
CMOS clear operation causes the system to automatically power up and immediately power
down after the CMOS clear procedure is followed and AC power is re-applied. If this happens,
remove the AC power cord, wait 30 seconds, and then reconnect the AC power cord. Power up
the system and proceed to the <F2> BIOS Setup utility to reset the desired settings.
Normal Integrated BMC functionality is disabled with the BMC Force Update jumper set to the
“enabled” position (pins 2-3). The server should never be run with the BMC Force Update jumper
set in this position and should only be used when the standard firmware update process fails.
This jumper should remain in the default (disabled) position (pins 1- 2) when the server is running
normally.
When performing a normal BIOS update procedure, the BIOS recovery jumper must be set to its
default position (pins 1-2).
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
119
Appendix B: BMC Sensor Tables
This appendix lists the sensor identification numbers and information about the sensor type, name,
supported thresholds, assertion and de-assertion information, and a brief description of the sensor
purpose. See the Intelligent Platform Management Interface Specification, Version 2.0 for sensor and
event/reading-type table information.
Sensor Type Codes
Sensor table given below lists the sensor identification numbers and information regarding the sensor
type, name, supported thresholds, assertion and de-assertion information, and a brief description of the
sensor purpose. Refer to the Intelligent Platform Management Interface Specification, Version 2.0 for
sensor and event/reading-type table information.
Sensor Type
The sensor type references the values in the Sensor Type Codes table in the Intelligent Platform
Management Interface Specification Second Generation v2.0. It provides a context to interpret
the sensor.
Event/Reading Type
The event/reading type references values from the Event/Reading Type Code Ranges and the
Generic Event/Reading Type Code tables in the Intelligent Platform Management Interface
Specification Second Generation v2.0. Digital sensors are specific type of discrete sensors that
only have two states.
Event Thresholds/Triggers
The following event thresholds are supported for threshold type sensors:
- [u,l][nr,c,nc] upper non-recoverable, upper critical, upper non-critical, lower
non-recoverable, lower critical, lower non-critical uc, lc upper critical, lower critical
Event triggers are supported event-generating offsets for discrete type sensors. The offsets can
be found in the Generic Event/Reading Type Code or Sensor Type Code tables in the Intelligent
Platform Management Interface Specification Second Generation v2.0, depending on whether the
sensor event/reading type is generic or a sensor-specific response.
Assertion/Deassertion
Assertion and de-assertion indicators reveal the type of events this sensor generates:
- As: Assertion
- De: De-assertion
Readable Value/Offsets
- Readable value indicates the type of value returned for threshold and other non-
discrete type sensors.
- Readable offsets indicate the offsets for discrete sensors that are readable by means
of the Get Sensor Reading command. Unless otherwise indicated, event triggers are
readable. Readable offsets consist of the reading type offsets that do not generate
events.
Event Data
Event data is the data that is included in an event message generated by the associated sensor.
For threshold-based sensors, these abbreviations are used:
- R: Reading value
- T: Threshold value
Rearm Sensors
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
120
The rearm is a request for the event status for a sensor to be rechecked and updated upon a
transition between good and bad states. Rearming the sensors can be done manually or
automatically. This column indicates the type supported by the sensor. The following
abbreviations are used in the comment column to describe a sensor:
- A: Auto-rearm
- M: Manual rearm
- I: Rearm by init agent
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the count of
hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the front panel status LED.
Standby
Some sensors operate on standby power. These sensors may be accessed and/or generate
events when the main (system) power is off, but AC power is present.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
121
Note: All sensors listed below may not be present on all platforms. Please check platform EPS section for platform applicability and
platform chassis section for chassis specific sensors. Redundancy sensors will be only present on systems with appropriate
hardware to support redundancy (for instance, fan or power supply).
Table 71. Integrated BMC Core Sensors
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Power Unit Status
(Pwr Unit Status)
01h
All
Power Unit
09h
Sensor
Specific
6Fh
00 - Power down
OK
As and
De
Trig
Offset
A
X
02 - 240 VA power
down
Fatal
04 - A/C lost
OK
05 - Soft power
control failure
Fatal
06 - Power unit failure
Power Unit
Redundancy1 (Pwr
Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully Redundant
OK
As and
De
Trig
Offset
M
X
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
Degraded
04 Non-redundant:
sufficient resources.
Transition from
insufficient state.
Degraded
05 - Non-redundant:
insufficient resources
Fatal
06 Redundant:
degraded from fully
redundant state.
Degraded
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
122
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
07 Redundant:
Transition from non-
redundant state.
Degraded
IPMI Watchdog
(IPMI Watchdog)
03h
All
Watchdog 2
23h
Sensor
Specific
6Fh
00 - Timer expired,
status only
OK
As
Trig
Offset
A
X
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer interrupt
Physical Security
(Physical Scrty)
04h
Chassis
Intrusion
is chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
00 - Chassis intrusion
Degraded
OK
As and
De
Trig
Offset
A
X
04 - LAN leash lost
FP Interrupt
(FP NMI Diag Int)
05h
Chassis -
specific
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 - Front panel
NMI/diagnostic
interrupt
OK
As
Trig
Offset
A
SMI Timeout
(SMI Timeout)
06h
All
SMI Timeout
F3h
Digital
Discrete
03h
01 State asserted
Fatal
As and
De
Trig
Offset
A
System Event Log
(System Event
Log)
07h
All
Event Logging
Disabled
10h
Sensor
Specific
6Fh
02 - Log area
reset/cleared
OK
As
Trig
Offset
A
X
System Event
(System Event)
08h
All
System Event
12h
Sensor
Specific
6Fh
02 - Undetermined
system H/W failure
04 PEF action
Fatal
OK
As and
De
As
-
Trig
Offset
A
X
Button Sensor
(Button)
09h
All
Button/Switch
14h
Sensor
Specific
6Fh
00 Power Button
02 Reset Button
OK
AS
_
Trig
Offset
A
X
BMC Watchdog
0Ah
All
Mgmt System
Health
28h
Digital
Discrete
03h
01 State Asserted
Degraded
As
Trig
Offset
A
-
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
123
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Voltage Regulator
Watchdog
(VR Watchdog)
0Bh
All
Voltage
02h
Digital
Discrete
03h
01 State Asserted
Fatal
As and
De
Trig
Offset
M
X
Fan Redundancy1
(Fan Redundancy)
0Ch
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully redundant
OK
As and
De
Trig
Offset
A
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
05 - Non-redundant:
insufficient resources.
Non-Fatal
06 Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant
degraded from non-
redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh
All
Temperature
01h
Digital
Discrete
03h
01 State Asserted
Fatal
As and
De
Trig
Offset
M
X
IO Module
Presence
(IO Mod Presence)
0Eh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present
OK
As and
De
Trig
Offset
M
-
SAS Module
Presence
(SAS Mod
Presence)
0Fh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present
OK
As and
De
Trig
Offset
M
X
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
124
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
BMC Firmware
Health
(BMC FW Health)
10h
All
Mgmt Health
28h
Sensor
Specific
6Fh
04 Sensor Failure
Degraded
As
-
Trig
Offset
A
X
System Airflow
(System Airflow)
11h
All
Other Units
0Bh
Threshold
01h
Analog
FW Update Status
12h
All
Version
Change 2Bh
OEM defined
x70h
00hUpdate started
01hUpdate
completed
successfully.
02hUpdate failure
OK
As
_
Trig
Offset
A
_
IO Module2
Presence
(IO Mod2
Presence)
13h
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present
OK
As and
De
Trig
Offset
M
-
Baseboard
Temperature 5
(Platform Specific)
14h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Baseboard
Temperature 6
(Platform Specific)
15h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
IO Module2
Temperature
(I/O Mod2 Temp)
16h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
PCI Riser 3
Temperature
(PCI Riser 5 Temp)
17h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
125
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
PCI Riser 4
Temperature
(PCI Riser 4 Temp)
18h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Baseboard +1.05V
Processor3 Vccp
(BB +1.05Vccp P3)
19h
Platform-
specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.05V
Processor4 Vccp
(BB +1.05Vccp P4)
1Ah
Platform-
specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard
Temperature 1
(Platform Specific)
20h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Front Panel
Temperature
(Front Panel Temp)
21h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
SSB Temperature
(SSB Temp)
22h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Baseboard
Temperature 2
(Platform Specific)
23h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Baseboard
Temperature 3
(Platform Specific)
24h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
126
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Baseboard
Temperature 4
(Platform Specific)
25h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
IO Module
Temperature
(I/O Mod Temp)
26h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
PCI Riser 1
Temperature
(PCI Riser 1 Temp)
27h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
IO Riser
Temperature
(IO Riser Temp)
28h
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Hot-swap
Backplane 1
Temperature
(HSBP 1 Temp)
29h
Chassis-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Hot-swap
Backplane 2
Temperature
(HSBP 2 Temp)
2Ah
Chassis-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Hot-swap
Backplane 3
Temperature
(HSBP 3 Temp)
2Bh
Chassis-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
PCI Riser 2
Temperature
(PCI Riser 2 Temp)
2Ch
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
127
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
SAS Module
Temperature
(SAS Mod Temp)
2Dh
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Exit Air
Temperature
(Exit Air Temp)
2Eh
Chassis
and
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Network Interface
Controller
Temperature
(LAN NIC Temp)
2Fh
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Fan Tachometer
Sensors
(Chassis specific
sensor names)
30h
3Fh
Chassis
and
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal2
As and
De
Analog
R, T
M
-
Fan Present
Sensors
(Fan x Present)
40h
4Fh
Chassis
and
Platform
Specific
Fan
04h
Generic
08h
01 - Device inserted
OK
As and
De
-
Triggered
Offset
Auto
-
Power Supply 1
Status
(PS1 Status)
50h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig
Offset
A
X
01 - Failure
Degraded
02 Predictive Failure
Degraded
03 - A/C lost
Degraded
06 Configuration
error
OK
Power Supply 2
Status
(PS2 Status)
51h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig
Offset
A
X
01 - Failure
Degraded
02 Predictive Failure
Degraded
03 - A/C lost
Degraded
06 Configuration
error
OK
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
128
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Power Supply 1
AC Power Input
(PS1 Power In)
54h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Power Supply 2
AC Power Input
(PS2 Power In)
55h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Power Supply 1
+12V % of
Maximum Current
Output
(PS1 Curr Out %)
58h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Power Supply 2
+12V % of
Maximum Current
Output
(PS2 Curr Out %)
59h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Power Supply 1
Temperature
(PS1 Temperature)
5Ch
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Power Supply 2
Temperature
(PS2 Temperature)
5Dh
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Hard Disk Drive 16
- 24 Status
(HDD 16 - 24
Status)
60h
68h
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
6Fh
00 - Drive Presence
OK
As and
De
Trig
Offset
A
X
01- Drive Fault
Degraded
07 - Rebuild/Remap in
progress
Degraded
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
129
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
69h
-
6Bh
Chassis-
specific
Microcontroller
16h
Discrete 0Ah
04- transition to Off
Line
Degraded
Trig
Offset
X
Processor 1 Status
(P1 Status)
70h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M
X
07 - Presence
OK
Processor 2 Status
(P2 Status)
71h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M
X
07 - Presence
OK
Processor 3 Status
(P3 Status)
72h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M
X
07 - Presence
OK
Processor 4 Status
(P4 Status)
73h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M
X
07 - Presence
OK
Processor 1
Thermal Margin
(P1 Therm Margin)
74h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 2
Thermal Margin
(P2 Therm Margin)
75h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 3
Thermal Margin
(P3 Therm Margin)
76h
Platform-
specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 4
Thermal Margin
(P4 Therm Margin)
77h
Platform-
specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 1
Thermal
Control %
(P1 Therm Ctrl %)
78h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
130
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 2
Thermal
Control %
(P2 Therm Ctrl %)
79h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A
Processor 3
Thermal
Control %
(P3 Therm Ctrl %)
7Ah
Platform-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A
Processor 4
Thermal
Control %
(P4 Therm Ctrl %)
7Bh
Platform-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A
Processor 1 ERR2
Timeout
(P1 ERR2)
7Ch
All
Processor
07h
Digital
Discrete
03h
01 State Asserted
fatal
As and
De
Trig
Offset
A
Processor 2 ERR2
Timeout
(P2 ERR2)
7Dh
All
Processor
07h
Digital
Discrete
03h
01 State Asserted
fatal
As and
De
Trig
Offset
A
Processor 3 ERR2
Timeout
(P3 ERR2)
7Eh
Platform-
specific
Processor
07h
Digital
Discrete
03h
01 State Asserted
fatal
As and
De
Trig
Offset
A
Processor 4 ERR2
Timeout
(P4 ERR2)
7Fh
Platform-
specific
Processor
07h
Digital
Discrete
03h
01 State Asserted
fatal
As and
De
Trig
Offset
A
Catastrophic Error
(CATERR)
80h
All
Processor
07h
Digital
Discrete
03h
01 State Asserted
fatal
As and
De
Trig
Offset
M
Processor1 MSID
Mismatch
(P1 MSID
Mismatch)
81h
All
Processor
07h
Digital
Discrete
03h
01 State Asserted
fatal
As and
De
Trig
Offset
M
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
131
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor
Population Fault
(CPU Missing)
82h
All
Processor
07h
Digital
Discrete
03h
01 State Asserted
Fatal
As and
De
Trig
Offset
M
Processor 1 DTS
Thermal Margin
(P1 DTS Therm
Mgn)
83h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 2 DTS
Thermal Margin
(P2 DTS Therm
Mgn)
84h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 3 DTS
Thermal Margin
(P3 DTS Therm
Mgn)
85h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 4 DTS
Thermal Margin
(P4 DTS Therm
Mgn)
86h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor2 MSID
Mismatch
(P2 MSID
Mismatch)
87h
All
Processor
07h
Digital
Discrete
03h
01 State Asserted
fatal
As and
De
Trig
Offset
M
Processor 1 VRD
Temperature
(P1 VRD Hot)
90h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
M
Processor 2 VRD
Temperature
(P2 VRD Hot)
91h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
M
Processor 3 VRD
Temperature
(P3 VRD Hot)
92h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Fatal
As and
De
Trig
Offset
M
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
132
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 4 VRD
Temperature
(P4 VRD Hot)
93h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Fatal
As and
De
Trig
Offset
M
Processor 1
Memory VRD Hot
0-1
(P1 Mem01 VRD
Hot)
94h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
A
Processor 1
Memory VRD Hot
2-3
(P1 Mem23 VRD
Hot)
95h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
A
Processor 2
Memory VRD Hot
0-1
(P2 Mem01 VRD
Hot)
96h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
A
Processor 2
Memory VRD Hot
2-3
(P2 Mem23 VRD
Hot)
97h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
A
Processor 3
Memory VRD Hot
0-1
(P3 Mem01 VRD
Hot)
98h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
A
Processor 3
Memory VRD Hot
2-3
(P4 Mem23 VRD
Hot)
99h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
A
Processor 4
Memory VRD Hot
0-1
(P4 Mem01 VRD
Hot)
9Ah
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
A
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
133
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 4
Memory VRD Hot
2-3
(P4 Mem23 VRD
Hot)
9Bh
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As and
De
Trig
Offset
A
Power Supply 1
Fan Tachometer 1
(PS1 Fan Tach 1)
A0h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State Asserted
Non-fatal
As and
De
-
Trig
Offset
M
-
Power Supply 1
Fan Tachometer 2
(PS1 Fan Tach 2)
A1h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State Asserted
Non-fatal
As and
De
-
Trig
Offset
M
-
Power Supply 2
Fan Tachometer 1
(PS2 Fan Tach 1)
A4h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State Asserted
Non-fatal
As and
De
-
Trig
Offset
M
-
Power Supply 2
Fan Tachometer 2
(PS2 Fan Tach 2)
A5h
Chassis-
specific
Fan
04h
Generic
digital
discrete
01 State Asserted
Non-fatal
As and
De
-
Trig
Offset
M
-
Processor 1 DIMM
Aggregate Thermal
Margin 1
(P1 DIMM Thrm
Mrgn1)
B0h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Processor 1 DIMM
Aggregate Thermal
Margin 2
(P1 DIMM Thrm
Mrgn2)
B1h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Processor 2 DIMM
Aggregate Thermal
Margin 1
(P2 DIMM Thrm
Mrgn1)
B2h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Processor 2 DIMM
Aggregate Thermal
Margin 2
(P2 DIMM Thrm
Mrgn2)
B3h
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
134
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 3 DIMM
Aggregate Thermal
Margin 1
(P3 DIMM Thrm
Mrgn1)
B4h
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Processor 3 DIMM
Aggregate Thermal
Margin 2
(P3 DIMM Thrm
Mrgn2)
B5h
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Processor 4 DIMM
Aggregate Thermal
Margin 1
(P4 DIMM Thrm
Mrgn1)
B6h
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Processor 4 DIMM
Aggregate Thermal
Margin 2
(P4 DIMM Thrm
Mrgn2)
B7h
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Fan Tachometer
Sensors
(Chassis specific
sensor names)
BAh
BFh
Chassis
and
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal2
As and
De
Analog
R, T
M
-
Processor 1 DIMM
Thermal Trip
(P1 Mem Thrm
Trip)
C0h
All
Memory
0Ch
Digital
Discrete
03h
0A- Critical
overtemperature
Fatal
As and
De
Trig
Offset
M
-
Processor 2 DIMM
Thermal Trip
(P2 Mem Thrm
Trip)
C1h
All
Memory
0Ch
Digital
Discrete
03h
0A- Critical
overtemperature
Fatal
As and
De
Trig
Offset
M
-
Processor 3 DIMM
Thermal Trip
(P3 Mem Thrm
Trip)
C2h
All
Memory
0Ch
Digital
Discrete
03h
0A- Critical
overtemperature
Fatal
As and
De
Trig
Offset
M
X
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
135
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Processor 4 DIMM
Thermal Trip
(P4 Mem Thrm
Trip)
C3h
All
Memory
0Ch
Digital
Discrete
03h
0A- Critical
overtemperature
Fatal
As and
De
Trig
Offset
M
X
Global Aggregate
Temperature
Margin 1
(Agg Therm Mrgn
1)
C8h
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature
Margin 2
(Agg Therm Mrgn
2)
C9h
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature
Margin 3
(Agg Therm Mrgn
3)
CAh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature
Margin 4
(Agg Therm Mrgn
4)
CBh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature
Margin 5
(Agg Therm Mrgn
5)
CCh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature
Margin 6
(Agg Therm Mrgn
6)
CDh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Global Aggregate
Temperature
Margin 7
(Agg Therm Mrgn
7)
CEh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
136
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Global Aggregate
Temperature
Margin 8
(Agg Therm Mrgn
8)
CFh
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Baseboard +12V
(BB +12.0V)
D0h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +5V
(BB +5.0V)
D1h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +3.3V
(BB +3.3V)
D2h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +5V
Stand-by
(BB +5.0V STBY)
D3h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Baseboard +3.3V
Auxiliary
(BB +3.3V AUX)
D4h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Baseboard +1.05V
Processor1 Vccp
(BB +1.05Vccp P1)
D6h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.05V
Processor2 Vccp
(BB +1.05Vccp P2)
D7h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
137
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Baseboard +1.5V
P1 Memory AB
VDDQ
(BB +1.5 P1MEM
AB)
D8h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.5V
P1 Memory CD
VDDQ
(BB +1.5 P1MEM
CD)
D9h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.5V
P2 Memory AB
VDDQ
(BB +1.5 P2MEM
AB)
DAh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.5V
P2 Memory CD
VDDQ
(BB +1.5 P2MEM
CD)
DBh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.8V
Aux
(BB +1.8V AUX)
DCh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.1V
Stand-by
(BB +1.1V STBY)
DDh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard CMOS
Battery
(BB +3.3V Vbat)
DEh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Appendix B: BMC Sensor Tables Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
138
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Baseboard +1.35V
P1 Low Voltage
Memory AB VDDQ
(BB +1.35 P1LV
AB)
E4h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.35V
P1 Low Voltage
Memory CD VDDQ
(BB +1.35 P1LV
CD)
E5h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.35V
P2 Low Voltage
Memory AB VDDQ
(BB +1.35 P2LV
AB)
E6h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +1.35V
P2 Low Voltage
Memory CD VDDQ
(BB +1.35 P2LV
CD)
E7h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +3.3V
Riser 1 Power
Good
(BB +3.3 RSR1
PGD)
EAh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Baseboard +3.3V
Riser 2 Power
Good
(BB +3.3 RSR2
PGD)
EBh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
Hard Disk Drive 1 -
15 Status
F0h
-
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
00 - Drive Presence
OK
As and
De
Trig
Offset
A
X
01- Drive Fault
Degraded
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.2 Intel order number G34153-003
139
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
(HDD 1 - 15
Status)
FEh
6Fh
07 - Rebuild/Remap in
progress
Degraded
Notes: 1. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply).
2. This is only applicable when the system doesn't support redundant fans. When fan redundancy is supported, then the contribution to system state is
driven by the fan redundancy sensor.
Appendix C: Platform Specific BMC Appendix Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
140
Appendix C: Platform Specific BMC Appendix
Intel® Server Board S2600IP
Introduction
This is an addendum document to BMC core EPS. This document describes platform and chassis specific
information.
Product ID
Bytes 11:12 (product ID) of Get Device ID command response: 55h 00h
IPMI Channel ID Assignments
The following table provides information on the BMC channel assignments:
Table 72. Intel® Server Board S2600IP - BMC Channel Assignments
Channel ID
Interface
Supports
Sessions
0
Primary IPMB
Yes
1
LAN 1
Yes
2
LAN 2 (platform specific)
Yes
3
LAN3 1
(Provided by the Intel® Dedicated Server Management NIC)
Yes
4
Reserved
Yes
5
USB
No
6
Secondary IPMB
No
7
SMM
No
8 0Dh
Reserved
0Eh
Self 2
0Fh
SMS/Receive Message Queue
No
Notes: 1. Optional HW supported by the server system.
2. Refers to the actual channel used to send the request.
ACPI S3 Sleep State Support
Not supported.
Processor Support for Intel®
Server Board S2600IP
Intel® Xeon® processor E5-2600 and E5-2600 v2 product family up to 135 Watt
Supported Chassis
Intel® Server Chassis P4208 (UPL with redundant fan 4U)
Intel® Server Chassis P4216 (UPL with redundant fan 4U)
Intel® Server Chassis P4224 (UPL with redundant fan 4U)
Intel® Server Chassis P4308 (UPL with redundant fan 4U)
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix C: Platform Specific BMC Appendix
Revision 1.2 Intel order number G34153-003
141
Intel® Server Chassis P4XXX (UPL with redundant fan 4U)
Intel® Server Chassis R2208 (BHP with redundant fan 2U)
Intel® Server Chassis R2216 (BHP with redundant fan 2U)
Intel® Server Chassis R2224 (BHP with redundant fan 2U)
Intel® Server Chassis R2308 (BHP with redundant fan 2U)
Intel® Server Chassis R2312 (BHP with redundant fan 2U)
Chassis-specific sensors
Table 73. Intel® Server Board S2600IP - Chassis-specific Sensors
Intel®
Server Chassis
Fan Tachometer
Sensors
Fan Presence Sensors
Physical Security
(Chassis intrusion)
sensor
FP Interrupt
(FP NMI Diag Int)
P4208/P4216/P4224/
P4308/P4XXX (UPL
with redundant fan
4U)
System Fan 1(30h)
Fan 1 Present (40h)
Physical Scrty (04h)
FP NMI Diag Int (05h)
System Fan 2(31h)
Fan 2 Present (41h)
NA
NA
System Fan 3 (32h)
Fan 3 Present (42h)
NA
NA
System Fan 4 (33h)
Fan 4 Present (43h)
NA
NA
System Fan 5 (34h)
Fan 5 Present (44h)
NA
NA
R2208/R2216/R2224/P
2308/P2312 (BHP with
redundant fan 2U)
System Fan 1 (30h)
Fan 1 Present (40h)
Physical Scrty (04h)
FP NMI Diag Int (05h)
System Fan 2 (31h)
Fan 2 Present (41h)
NA
NA
System Fan 3 (32h)
Fan 3 Present (42h)
NA
NA
System Fan 4 (33h)
Fan 4 Present (43h)
NA
NA
System Fan 5 (34h)
Fan 5 Present (44h)
NA
NA
System Fan 6 (35h)
Fan 6 Present (45h)
NA
NA
Hot-plug fan support
Supported on:
Intel® Server Chassis P4208 (UPL with redundant fan 4U)
Intel® Server Chassis P4216 (UPL with redundant fan 4U)
Intel® Server Chassis P4224 (UPL with redundant fan 4U)
Intel® Server Chassis P4308 (UPL with redundant fan 4U)
Intel® Server Chassis P4XXX (UPL with redundant fan 4U)
Intel® Server Chassis R2208 (BHP with redundant fan 2U)
Intel® Server Chassis R2216 (BHP with redundant fan 2U)
Intel® Server Chassis R2224 (BHP with redundant fan 2U)
Intel® Server Chassis R2308 (BHP with redundant fan 2U)
Intel® Server Chassis R2312 (BHP with redundant fan 2U)
Fan redundancy support
Supported on:
Intel® Server Chassis P4208 (UPL with redundant fan 4U)
Intel® Server Chassis P4216 (UPL with redundant fan 4U)
Intel® Server Chassis P4224 (UPL with redundant fan 4U)
Appendix C: Platform Specific BMC Appendix Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
142
Intel® Server Chassis P4308 (UPL with redundant fan 4U)
Intel® Server Chassis P4XXX (UPL with redundant fan 4U)
Intel® Server Chassis R2208 (BHP with redundant fan 2U)
Intel® Server Chassis R2216 (BHP with redundant fan 2U)
Intel® Server Chassis R2224 (BHP with redundant fan 2U)
Intel® Server Chassis R2308 (BHP with redundant fan 2U)
Intel® Server Chassis R2312 (BHP with redundant fan 2U)
Fan domain definition
Table 74. Intel® Server Board S2600IP - Fan Domain Definition
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
P4208/P4216/P4224/P4
308/P4XXX (UPL with
redundant fan 4U)
0
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
System Fan 1(30h)
1
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
System Fan 2(31h)
2
BB P2 VR Temp(24h)
BB MEM VR Temp(25h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
HSBP 3 Temp(2Bh)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
HDD 20 Status(64h)
HDD 21 Status(65h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
System Fan 3(32h)
3
BB P2 VR Temp(24h)
HSBP 3 Temp(2Bh)
Exit Air Temp(2Eh)
P1 Therm Margin(74h)
System Fan 4(33h)
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix C: Platform Specific BMC Appendix
Revision 1.2 Intel order number G34153-003
143
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
P2 Therm Margin(75h)
DIMM Thrm Mrgn 1(B0h)
DIMM Thrm Mrgn 4(B3h)
4
BB P2 VR Temp(24h)
HSBP 3 Temp(2Bh)
Exit Air Temp(2Eh)
PS1 Temperature(5Ch)
PS2 Temperature(5Dh)
HDD 20 Status(64h)
HDD 21 Status(65h)
DIMM Thrm Mrgn 1(B0h)
DIMM Thrm Mrgn 4(B3h)
System Fan 5(34h)
R2208/R2216/R2224/P2
308/P2312 (BHP with
redundant fan 2U)
0
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
System Fan 1(30h)
1
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
System Fan 2(31h)
2
SSB Temp(22h)
BB P2 VR Temp(24h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
P1 Therm Margin(74h)
P2 Therm Margin(75h)
P2 DTS Therm Mgn(84h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
System Fan 3(32h)
3
BB P2 VR Temp(24h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
HSBP 3 Temp(2Bh)
Exit Air Temp(2Eh)
P1 Therm Margin(74h)
P2 Therm Margin(75h)
System Fan 4(33h)
Appendix C: Platform Specific BMC Appendix Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
144
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
DIMM Thrm Mrgn 1(B0h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
DIMM Thrm Mrgn 4(B3h)
4
SSB Temp(22h)
BB P2 VR Temp(24h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
P1 Therm Margin(74h)
P2 Therm Margin(75h)
P2 DTS Therm Mgn(84h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
System Fan 5(34h)
5
BB P2 VR Temp(24h)
HSBP 1 Temp(29h)
HSBP 2 Temp(2Ah)
HSBP 3 Temp(2Bh)
Exit Air Temp(2Eh)
P1 Therm Margin(74h)
P2 Therm Margin(75h)
DIMM Thrm Mrgn 1(B0h)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
DIMM Thrm Mrgn 4(B3h)
System Fan 6(35h)
HSC Availability
Intel® Server Chassis P4208 (UPL)
o 8-bay 2.5” HDD – FXX8X25HSBP
Intel® Server Chassis P4216 (UPL)
o 8-bay 2.5” HDD – FXX8X25HSBP
Intel® Server Chassis P4224 (UPL)
o 8-bay 2.5” HDD – FXX8X25HSBP
Intel® Server Chassis P4308 (UPL)
o 8-bay 3.5” HDD – FUP8X35HSBP
Intel® Server Chassis R2208 (BHP)
o 8-bay 2.5” HDD – FXX8X25HSBP
Intel® Server Chassis R2216 (BHP)
o 8-bay 2.5” HDD – FXX8X25HSBP
Intel® Server Chassis R2224 (BHP)
o 8-bay 2.5” HDD – FXX8X25HSBP
Intel® Server Chassis R2308 (BHP)
o 8-bay 3.5” HDD F2U8X35HSBP
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix C: Platform Specific BMC Appendix
Revision 1.2 Intel order number G34153-003
145
Intel® Server Chassis R2312 (BHP)
o 12-bay 3.5” HDD F2U12X35HSBP
Power unit support
Intel® Server Chassis P4208/P4216/P4224/P4308 (UPL)
Table 75. Intel® Server Chassis P4208/P4216/P4224/P4308 (UPL) Power support
PS Module
Number
PMBus*
Product Name (in
product area of
the FRU)
PSU
Redundant
Cold
Redundant
Fans in
each PS
750W HS
Power Supply
Supported
DPS-750XB A
Supported
Supported
1 PS fan
1200W HS
Power Supply
Supported
DPS-1200TB A
Supported
Supported
2 PS fan
Intel® Server Chassis R2208/R2216/R2224/R2308/R2312 (BHP)
Table 76. Intel® Server Chassis R2208/R2216/R2224/R2308/R2312 (BHP) Power support
PS Module
Number
PMBus*
Product Name(in
product area of
the FRU)
PSU
Redundant
Cold
Redundant
Fans in
each PS
750W HS
Power Supply
Supported
FS750HS1-00
Supported
Supported
1 PS fan
Redundant Fans only for Intel®
Server Chassis
Intel® Server Chassis P4208 (UPL with redundant fan 4U)
Intel® Server Chassis P4216 (UPL with redundant fan 4U)
Intel® Server Chassis P4224 (UPL with redundant fan 4U)
Intel® Server Chassis P4308 (UPL with redundant fan 4U)
Intel® Server Chassis P4XXX (UPL with redundant fan 4U)
Intel® Server Chassis R2208 (BHP with redundant fan 2U)
Intel® Server Chassis R2216 (BHP with redundant fan 2U)
Intel® Server Chassis R2224 (BHP with redundant fan 2U)
Intel® Server Chassis R2308 (BHP with redundant fan 2U)
Intel® Server Chassis R2312 (BHP with redundant fan 2U)
Fan Fault LED support
Fan fault LEDs are available on the baseboard and on the hot-swap redundant fans
available on the following chassis:
Intel® Server Chassis P4208 (UPL with redundant fan 4U)
Intel® Server Chassis P4216 (UPL with redundant fan 4U)
Intel® Server Chassis P4224 (UPL with redundant fan 4U)
Intel® Server Chassis P4308 (UPL with redundant fan 4U)
Appendix C: Platform Specific BMC Appendix Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
146
Intel® Server Chassis P4XXX (UPL with redundant fan 4U)
Intel® Server Chassis R2208 (BHP with redundant fan 2U)
Intel® Server Chassis R2216 (BHP with redundant fan 2U)
Intel® Server Chassis R2224 (BHP with redundant fan 2U)
Intel® Server Chassis R2308 (BHP with redundant fan 2U)
Intel® Server Chassis R2312 (BHP with redundant fan 2U)
Memory Throttling support
Baseboard supports this feature.
Intel® Workstation Board W2600CR
Introduction
This is an addendum document to BMC core EPS. This document describes platform and chassis specific
information.
Product ID
Bytes 11:12 (product ID) of Get Device ID command response: 56h 00h
IPMI Channel ID Assignments
The following table provides information on the BMC channel assignments:
Table 77. Intel® Workstation Board W2600CR - BMC Channel Assignments
Channel ID
Interface
Supports
Sessions
0
Primary IPMB
Yes
1
LAN 1
Yes
2
LAN 2 (platform specific)
Yes
3
LAN3 1
(Provided by the Intel® Dedicated Server Management NIC)
Yes
4
Reserved
Yes
5
USB
No
6
Secondary IPMB
No
7
SMM
No
8 0Dh
Reserved
0Eh
Self 2
0Fh
SMS/Receive Message Queue
No
Notes: 1. Optional HW supported by the server system.
2. Refers to the actual channel used to send the request.
ACPI S3 Sleep State Support
Supported
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix C: Platform Specific BMC Appendix
Revision 1.2 Intel order number G34153-003
147
Processor Support for Intel®
Server Board W2600CR
Intel® Xeon® processor E5-2600 product family up to 150 Watt
Intel® Xeon® processor E5-2600 v2 product family up to 150 Watt
Supported Chassis
Intel® Server Chassis P4304 (UPL with fixed fan 4U)
Chassis-specific sensors
Table 78. Intel® Workstation Board W2600CR - Chassis-specific sensors
Intel®
Server Chassis
Fan Tachometer Sensors
Fan
Presene
Sensors
Physical Security
(Chassis intrusion)
sensor
FP Interrupt
(FP NMI Diag Int)
P4304 (UPL with
fixed fan 4U)
System Fan 1(30h)
NA
Physical Scrty(04h)
FP NMI Diag Int(05h)
System Fan 2(31h)
NA
NA
NA
Processor 1 Fan (36h)
NA
NA
NA
Processor 2 Fan (37h)detected
NA
NA
NA
Hot-plug fan support
Not supported.
Fan redundancy support
Not supported.
Board specific feature
Board has not supported serial port A, and SOL will only use serial port B.
Fan domain definition
Table 79. Intel® Workstation Board W2600CR - Fan domain definition
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
P4304 (UPL
with fixed
fan 4U)
0
SSB Temp(22h)
BB BMC Temp(23h)
BB MEM VR Temp(25h)
I/O Mod Temp(26h)
SAS Mod Temp(2Dh)
Exit Air Temp(2Eh)
LAN NIC Temp(2Fh)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
System Fan 1(30h)
1
BB P2 VR Temp(24h)
BB MEM VR Temp(25h)
Exit Air Temp(2Eh)
HDD 20 Status(64h)
HDD 21 Status(65h)
DIMM Thrm Mrgn 1(B0h)
System Fan 2(31h)
Appendix C: Platform Specific BMC Appendix Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
148
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
DIMM Thrm Mrgn 2(B1h)
DIMM Thrm Mrgn 3(B2h)
DIMM Thrm Mrgn 4(B3h)
6
Exit Air Temp(2Eh)
P1 Therm Margin(74h)
Processor 1 Fan(36h)
7
BB P2 VR Temp(24h)
Exit Air Temp(2Eh)
P2 Therm Margin(75h)
Processor 2 Fan(37h)
HSC Availability
Not supported.
Power unit support
Intel® Server Chassis P4304 (UPL)
Table 80. Intel® Server Chassis P4304 (UPL) Power support
PS Module
Number
PMBus*
Product Name (in
product area of the
FRU)
PSU Redundant
Cold
Redundant
Fans in each
PS
750W HS
Power Supply
Supported
DPS-750XB A
Supported
Supported
1 PS fan
1200W HS
Power Supply
Supported
DPS-1200TB A
Supported
Supported
2PS fan
Redundant Fans only for Intel®
Server Chassis
Not supported.
Fan Fault LED support
Not supported.
Memory Throttling support
Baseboard supports this feature.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSAppendix D: POST Code Diagnostic LED Decoder
Revision 1.2 Intel order number G34153-003
149
Appendix D: POST Code Diagnostic LED Decoder
During the system boot process, the BIOS executes a number of platform configuration
processes, each of which is assigned a specific hex POST code number. As each configuration
routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the
back edge of the server board. To assist in troubleshooting a system hang during the POST
process, the Diagnostic LEDs can be used to identify the last POST process that was executed.
Each POST code is represented by a sequence of eight amber diagnostic LEDs. The POST
codes are divided into two nibbles, an upper nibble and a lower nibble. The upper nibble bits are
represented by diagnostic LEDs #4, #5, #6, and #7. The lower nibble bits are represented by
diagnostics LEDs #0, #1, #2, and #3. If the bit is set in the upper and lower nibbles, then the
corresponding LED is lit. If the bit is clear, then the corresponding LED is off.
The diagnostic LED #7 is labeled as “MSB”, and the diagnostic LED #0 is labeled as “LSB”.
Figure 36. POST Code Diagnostic LED Decoder
Appendix D: POST Code Diagnostic LED Decoder Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
150
Note: Diagnostic LEDs are best read and decoded when viewing the LEDs from the back of the system
Table 81. POST Progress Code LED Example
LEDs
Upper Nibble AMBER LEDs
Lower Nibble GREEN LEDs
MSB
LSB
LED #7
LED #6
LED #5
LED #4
LED #3
LED #2
LED #1
LED #0
8h
4h
2h
1h
8h
4h
2h
1h
Status
ON
OFF
ON
OFF
ON
ON
OFF
OFF
Results
1
0
1
0
1
1
0
0
Ah
Ch
Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are concatenated as
ACh
The following table provides a list of all POST progress codes.
Table 82. POST Progress Codes
Checkpoint
Diagnostic LED Decoder
Description
1 = LED On, 0 = LED Off
Upper Nibble
Lower Nibble
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
LED #
#7
#6
#5
#4
#3
#2
#1
#0
SEC Phase
01h
0
0
0
0
0
0
0
1
First POST code after CPU reset
02h
0
0
0
0
0
0
1
0
Microcode load begin
03h
0
0
0
0
0
0
1
1
CRAM initialization begin
04h
0
0
0
0
0
1
0
0
Pei Cache When Disabled
05h
0
0
0
0
0
1
0
1
SEC Core At Power On Begin.
06h
0
0
0
0
0
1
1
0
Early CPU initialization during Sec Phase.
07h
0
0
0
0
0
1
1
1
Early SB initialization during Sec Phase.
08h
0
0
0
0
1
0
0
0
Early NB initialization during Sec Phase.
09h
0
0
0
0
1
0
0
1
End Of Sec Phase.
0Eh
0
0
0
0
1
1
1
0
Microcode Not Found.
0Fh
0
0
0
0
1
1
1
1
Microcode Not Loaded.
PEI Phase
10h
0
0
0
1
0
0
0
0
PEI Core
11h
0
0
0
1
0
0
0
1
CPU PEIM
15h
0
0
0
1
0
1
0
1
NB PEIM
19h
0
0
0
1
1
0
0
1
SB PEIM
MRC Process Codes MRC Progress Code Sequence is executed - See Table 83.
PEI Phase continued…
31h
0
0
1
1
0
0
0
1
Memory Installed
32h
0
0
1
1
0
0
1
0
CPU PEIM (Cpu Init)
33h
0
0
1
1
0
0
1
1
CPU PEIM (Cache Init)
34h
0
0
1
1
0
1
0
0
CPU PEIM (BSP Select)
35h
0
0
1
1
0
1
0
1
CPU PEIM (AP Init)
36h
0
0
1
1
0
1
1
0
CPU PEIM (CPU SMM Init)
4Fh
0
1
0
0
1
1
1
1
Dxe IPL started
DXE Phase
60h
0
1
1
0
0
0
0
0
DXE Core started
61h
0
1
1
0
0
0
0
1
DXE NVRAM Init
62h
0
1
1
0
0
0
1
0
SB RUN Init
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSAppendix D: POST Code Diagnostic LED Decoder
Revision 1.2 Intel order number G34153-003
151
Checkpoint
Diagnostic LED Decoder
Description
1 = LED On, 0 = LED Off
Upper Nibble
Lower Nibble
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
LED #
#7
#6
#5
#4
#3
#2
#1
#0
63h
0
1
1
0
0
0
1
1
Dxe CPU Init
68h
0
1
1
0
1
0
0
0
DXE PCI Host Bridge Init
69h
0
1
1
0
1
0
0
1
DXE NB Init
6Ah
0
1
1
0
1
0
1
0
DXE NB SMM Init
70h
0
1
1
1
0
0
0
0
DXE SB Init
71h
0
1
1
1
0
0
0
1
DXE SB SMM Init
72h
0
1
1
1
0
0
1
0
DXE SB devices Init
78h
0
1
1
1
1
0
0
0
DXE ACPI Init
79h
0
1
1
1
1
0
0
1
DXE CSM Init
90h
1
0
0
1
0
0
0
0
DXE BDS Started
91h
1
0
0
1
0
0
0
1
DXE BDS connect drivers
92h
1
0
0
1
0
0
1
0
DXE PCI Bus begin
93h
1
0
0
1
0
0
1
1
DXE PCI Bus HPC Init
94h
1
0
0
1
0
1
0
0
DXE PCI Bus enumeration
95h
1
0
0
1
0
1
0
1
DXE PCI Bus resource requested
96h
1
0
0
1
0
1
1
0
DXE PCI Bus assign resource
97h
1
0
0
1
0
1
1
1
DXE CON_OUT connect
98h
1
0
0
1
1
0
0
0
DXE CON_IN connect
99h
1
0
0
1
1
0
0
1
DXE SIO Init
9Ah
1
0
0
1
1
0
1
0
DXE USB start
9Bh
1
0
0
1
1
0
1
1
DXE USB reset
9Ch
1
0
0
1
1
1
0
0
DXE USB detect
9Dh
1
0
0
1
1
1
0
1
DXE USB enable
A1h
1
0
1
0
0
0
0
1
DXE IDE begin
A2h
1
0
1
0
0
0
1
0
DXE IDE reset
A3h
1
0
1
0
0
0
1
1
DXE IDE detect
A4h
1
0
1
0
0
1
0
0
DXE IDE enable
A5h
1
0
1
0
0
1
0
1
DXE SCSI begin
A6h
1
0
1
0
0
1
1
0
DXE SCSI reset
A7h
1
0
1
0
0
1
1
1
DXE SCSI detect
A8h
1
0
1
0
1
0
0
0
DXE SCSI enable
A9h
1
0
1
0
1
0
0
1
DXE verifying SETUP password
ABh
1
0
1
0
1
0
1
1
DXE SETUP start
ACh
1
0
1
0
1
1
0
0
DXE SETUP input wait
ADh
1
0
1
0
1
1
0
1
DXE Ready to Boot
AEh
1
0
1
0
1
1
1
0
DXE Legacy Boot
AFh
1
0
1
0
1
1
1
1
DXE Exit Boot Services
B0h
1
0
1
1
0
0
0
0
RT Set Virtual Address Map Begin
B1h
1
0
1
1
0
0
0
1
RT Set Virtual Address Map End
Appendix D: POST Code Diagnostic LED Decoder Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
152
Checkpoint
Diagnostic LED Decoder
Description
1 = LED On, 0 = LED Off
Upper Nibble
Lower Nibble
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
LED #
#7
#6
#5
#4
#3
#2
#1
#0
B2h
1
0
1
1
0
0
1
0
DXE Legacy Option ROM init
B3h
1
0
1
1
0
0
1
1
DXE Reset system
B4h
1
0
1
1
0
1
0
0
DXE USB Hot plug
B5h
1
0
1
1
0
1
0
1
DXE PCI BUS Hot plug
B6h
1
0
1
1
0
1
1
0
DXE NVRAM cleanup
B7h
1
0
1
1
0
1
1
1
DXE Configuration Reset
00h
0
0
0
0
0
0
0
0
INT19
S3 Resume
E0h
1
1
0
1
0
0
0
0
S3 Resume PEIM (S3 started)
E1h
1
1
0
1
0
0
0
1
S3 Resume PEIM (S3 boot script)
E2h
1
1
0
1
0
0
1
0
S3 Resume PEIM (S3 Video Repost)
E3h
1
1
0
1
0
0
1
1
S3 Resume PEIM (S3 OS wake)
BIOS Recovery
F0h
1
1
1
1
0
0
0
0
PEIM which detected forced Recovery condition
F1h
1
1
1
1
0
0
0
1
PEIM which detected User Recovery condition
F2h
1
1
1
1
0
0
1
0
Recovery PEIM (Recovery started)
F3h
1
1
1
1
0
0
1
1
Recovery PEIM (Capsule found)
F4h
1
1
1
1
0
1
0
0
Recovery PEIM (Capsule loaded)
POST Memory Initialization MRC Diagnostic Codes
There are two types of POST Diagnostic Codes displayed by the MRC during memory
initialization; Progress Codes and Fatal Error Codes.
The MRC Progress Codes are displays to the Diagnostic LEDs that show the execution point in
the MRC operational path at each step.
Table 83. MRC Progress Codes
Checkpoint
Diagnostic LED Decoder
Description
1 = LED On, 0 = LED Off
Upper Nibble
Lower Nibble
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
LED
#7
#6
#5
#4
#3
#2
#1
#0
MRC Progress Codes
B0h
1
0
1
1
0
0
0
0
Detect DIMM population
B1h
1
0
1
1
0
0
0
1
Set DDR3 frequency
B2h
1
0
1
1
0
0
1
0
Gather remaining SPD data
B3h
1
0
1
1
0
0
1
1
Program registers on the memory controller level
B4h
1
0
1
1
0
1
0
0
Evaluate RAS modes and save rank information
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPSAppendix D: POST Code Diagnostic LED Decoder
Revision 1.2 Intel order number G34153-003
153
Checkpoint
Diagnostic LED Decoder
Description
1 = LED On, 0 = LED Off
Upper Nibble
Lower Nibble
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
LED
#7
#6
#5
#4
#3
#2
#1
#0
B5h
1
0
1
1
0
1
0
1
Program registers on the channel level
B6h
1
0
1
1
0
1
1
0
Perform the JEDEC defined initialization sequence
B7h
1
0
1
1
0
1
1
1
Train DDR3 ranks
B8h
1
0
1
1
1
0
0
0
Initialize CLTT/OLTT
B9h
1
0
1
1
1
0
0
1
Hardware memory test and init
BAh
1
0
1
1
1
0
1
0
Execute software memory init
BBh
1
0
1
1
1
0
1
1
Program memory map and interleaving
BCh
1
0
1
1
1
1
0
0
Program RAS configuration
BFh
1
0
1
1
1
1
1
1
MRC is done
Memory Initialization at the beginning of POST includes multiple functions, including: discovery,
channel training, validation that the DIMM population is acceptable and functional, initialization
of the IMC and other hardware settings, and initialization of applicable RAS configurations.
When a major memory initialization error occurs and prevents the system from booting with data
integrity, a beep code is generated, the MRC will display a fatal error code on the diagnostic
LEDs, and a system halt command is executed. Fatal MRC error halts do NOT change the state
of the System Status LED, and they do NOT get logged as SEL events. The following table lists
all MRC fatal errors that are displayed to the Diagnostic LEDs.
Table 84. MRC Fatal Error Codes
Checkpoint
Diagnostic LED Decoder
Description
1 = LED On, 0 = LED Off
Upper Nibble
Lower Nibble
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
LED
#7
#6
#5
#4
#3
#2
#1
#0
MRC Fatal Error Codes
E8h
1
1
1
0
1
0
0
0
No usable memory error
01h = No memory was detected by SPD read, or invalid config
that causes no operable memory.
02h = Memory DIMMs on all channels of all sockets are disabled
due to hardware memtest error.
3h = No memory installed. All channels are disabled.
E9h
1
1
1
0
1
0
0
1
Memory is locked by Intel Trusted Execution Technology and is
inaccessible
EAh
1
1
1
0
1
0
1
0
DDR3 channel training error
01h = Error on read DQ/DQS (Data/Data Strobe) init
02h = Error on Receive Enable
3h = Error on Write Leveling
04h = Error on write DQ/DQS (Data/Data Strobe
EBh
1
1
1
0
1
0
1
1
Memory test failure
01h = Software memtest failure.
Appendix D: POST Code Diagnostic LED Decoder Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
154
Checkpoint
Diagnostic LED Decoder
Description
1 = LED On, 0 = LED Off
Upper Nibble
Lower Nibble
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
LED
#7
#6
#5
#4
#3
#2
#1
#0
02h = Hardware memtest failed.
03h = Hardware Memtest failure in Lockstep Channel mode
requiring a channel to be disabled. This is a fatal error which
requires a reset and calling MRC with a different RAS mode to
retry.
EDh
1
1
1
0
1
1
0
1
DIMM configuration population error
01h = Different DIMM types (UDIMM, RDIMM, LRDIMM) are
detected installed in the system.
02h = Violation of DIMM population rules.
03h = The 3rd DIMM slot cannot be populated when QR DIMMs
are installed.
04h = UDIMMs are not supported in the 3rd DIMM slot.
05h = Unsupported DIMM Voltage.
EFh
1
1
1
0
1
1
1
1
Indicates a CLTT table structure error
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix E: POST Error Messages and Handling
Revision 1.2 Intel order number G34153-003
155
Appendix E: POST Error Messages and Handling
Most error conditions encountered during POST are reported using POST Error Codes. These
codes represent specific failures, warnings, or are informational. POST Error Codes may be
displayed in the Error Manager display screen, and are always logged to the System Event Log
(SEL). Logged events are available to System Management applications, including Remote and
Out of Band (OOB) management.
There are exception cases in early initialization where system resources are not adequately
initialized for handling POST Error Code reporting. These cases are primarily Fatal Error
conditions resulting from initialization of processors and memory, and they are handed by a
Diagnostic LED display with a system halt.
The following table lists the supported POST Error Codes. Each error code is assigned an error
type which determines the action the BIOS will take when the error is encountered. Error types
include Minor, Major, and Fatal. The BIOS action for each is defined as follows:
Minor: The error message is displayed on the screen or on the Error Manager screen,
and an error is logged to the SEL. The system continues booting in a degraded state.
The user may want to replace the erroneous unit. The POST Error Pause option setting
in the BIOS setup does not have any effect on this error.
Major: The error message is displayed on the Error Manager screen, and an error is
logged to the SEL. The POST Error Pause option setting in the BIOS setup determines
whether the system pauses to the Error Manager for this type of error so the user can
take immediate corrective action or the system continues booting.
Note that for 0048 “Password check failed”, the system halts, and then after the next
reset/reboot will displays the error code on the Error Manager screen.
Fatal: The system halts during post at a blank screen with the text “Unrecoverable
fatal error found. System will not boot until the error is resolved” and “Press <F2>
to enter setup” The POST Error Pause option setting in the BIOS setup does not have
any effect with this class of error.
When the operator presses the F2 key on the keyboard, the error message is displayed
on the Error Manager screen, and an error is logged to the SEL with the error code. The
system cannot boot unless the error is resolved. The user needs to replace the faulty
part and restart the system.
Note: The POST error codes in the following table are common to all current generation Intel
server platforms. Features present on a given server board/system will determine which of the
listed error codes are supported.
Table 85. POST Error Codes and Messages
Error Code
Error Message
Response
0012
System RTC date/time not set
Major
0048
Password check failed
Major
0140
PCI component encountered a PERR error
Major
Appendix E: POST Error Messages and Handling Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
156
Error Code
Error Message
Response
0141
PCI resource conflict
Major
0146
PCI out of resources error
Major
0191
Processor core/thread count mismatch detected
Fatal
0192
Processor cache size mismatch detected
Fatal
0194
Processor family mismatch detected
Fatal
0195
Processor Intel(R) QPI link frequencies unable to synchronize
Fatal
0196
Processor model mismatch detected
Fatal
0197
Processor frequencies unable to synchronize
Fatal
5220
BIOS Settings reset to default settings
Major
5221
Passwords cleared by jumper
Major
5224
Password clear jumper is Set
Major
8130
Processor 01 disabled
Major
8131
Processor 02 disabled
Major
8132
Processor 03 disabled
Major
8133
Processor 04 disabled
Major
8160
Processor 01 unable to apply microcode update
Major
8161
Processor 02 unable to apply microcode update
Major
8162
Processor 03 unable to apply microcode update
Major
8163
Processor 04 unable to apply microcode update
Major
8170
Processor 01 failed Self Test (BIST)
Major
8171
Processor 02 failed Self Test (BIST)
Major
8172
Processor 03 failed Self Test (BIST)
Major
8173
Processor 04 failed Self Test (BIST)
Major
8180
Processor 01 microcode update not found
Minor
8181
Processor 02 microcode update not found
Minor
8182
Processor 03 microcode update not found
Minor
8183
Processor 04 microcode update not found
Minor
8190
Watchdog timer failed on last boot
Major
8198
OS boot watchdog timer failure
Major
8300
Baseboard management controller failed self-test
Major
8305
Hot Swap Controller failure
Major
83A0
Management Engine (ME) failed Selftest
Major
83A1
Management Engine (ME) Failed to respond.
Major
84F2
Baseboard management controller failed to respond
Major
84F3
Baseboard management controller in update mode
Major
84F4
Sensor data record empty
Major
84FF
System event log full
Minor
8500
Memory component could not be configured in the selected RAS mode
Major
8501
DIMM Population Error
Major
8520
DIMM_A1 failed test/initialization
Major
8521
DIMM_A2 failed test/initialization
Major
8522
DIMM_A3 failed test/initialization
Major
8523
DIMM_B1 failed test/initialization
Major
8524
DIMM_B2 failed test/initialization
Major
8525
DIMM_B3 failed test/initialization
Major
8526
DIMM_C1 failed test/initialization
Major
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix E: POST Error Messages and Handling
Revision 1.2 Intel order number G34153-003
157
Error Code
Error Message
Response
8527
DIMM_C2 failed test/initialization
Major
8528
DIMM_C3 failed test/initialization
Major
8529
DIMM_D1 failed test/initialization
Major
852A
DIMM_D2 failed test/initialization
Major
852B
DIMM_D3 failed test/initialization
Major
852C
DIMM_E1 failed test/initialization
Major
852D
DIMM_E2 failed test/initialization
Major
852E
DIMM_E3 failed test/initialization
Major
852F
DIMM_F1 failed test/initialization
Major
8530
DIMM_F2 failed test/initialization
Major
8531
DIMM_F3 failed test/initialization
Major
8532
DIMM_G1 failed test/initialization
Major
8533
DIMM_G2 failed test/initialization
Major
8534
DIMM_G3 failed test/initialization
Major
8535
DIMM_H1 failed test/initialization
Major
8536
DIMM_H2 failed test/initialization
Major
8537
DIMM_H3 failed test/initialization
Major
8538
DIMM_I1 failed test/initialization
Major
8539
DIMM_I2 failed test/initialization
Major
853A
DIMM_I3 failed test/initialization
Major
853B
DIMM_J1 failed test/initialization
Major
853C
DIMM_J2 failed test/initialization
Major
853D
DIMM_J3 failed test/initialization
Major
853E
DIMM_K1 failed test/initialization
Major
853F (Go to 85C0)
DIMM_K2 failed test/initialization
Major
8540
DIMM_A1 disabled
Major
8541
DIMM_A2 disabled
Major
8542
DIMM_A3 disabled
Major
8543
DIMM_B1 disabled
Major
8544
DIMM_B2 disabled
Major
8545
DIMM_B3 disabled
Major
8546
DIMM_C1 disabled
Major
8547
DIMM_C2 disabled
Major
8548
DIMM_C3 disabled
Major
8549
DIMM_D1 disabled
Major
854A
DIMM_D2 disabled
Major
854B
DIMM_D3 disabled
Major
854C
DIMM_E1 disabled
Major
854D
DIMM_E2 disabled
Major
854E
DIMM_E3 disabled
Major
854F
DIMM_F1 disabled
Major
8550
DIMM_F2 disabled
Major
8551
DIMM_F3 disabled
Major
8552
DIMM_G1 disabled
Major
8553
DIMM_G2 disabled
Major
Appendix E: POST Error Messages and Handling Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
158
Error Code
Error Message
Response
8554
DIMM_G3 disabled
Major
8555
DIMM_H1 disabled
Major
8556
DIMM_H2 disabled
Major
8557
DIMM_H3 disabled
Major
8558
DIMM_I1 disabled
Major
8559
DIMM_I2 disabled
Major
855A
DIMM_I3 disabled
Major
855B
DIMM_J1 disabled
Major
855C
DIMM_J2 disabled
Major
855D
DIMM_J3 disabled
Major
855E
DIMM_K1 disabled
Major
855F
(Go to 85D0)
DIMM_K2 disabled
Major
8560
DIMM_A1 encountered a Serial Presence Detection (SPD) failure
Major
8561
DIMM_A2 encountered a Serial Presence Detection (SPD) failure
Major
8562
DIMM_A3 encountered a Serial Presence Detection (SPD) failure
Major
8563
DIMM_B1 encountered a Serial Presence Detection (SPD) failure
Major
8564
DIMM_B2 encountered a Serial Presence Detection (SPD) failure
Major
8565
DIMM_B3 encountered a Serial Presence Detection (SPD) failure
Major
8566
DIMM_C1 encountered a Serial Presence Detection (SPD) failure
Major
8567
DIMM_C2 encountered a Serial Presence Detection (SPD) failure
Major
8568
DIMM_C3 encountered a Serial Presence Detection (SPD) failure
Major
8569
DIMM_D1 encountered a Serial Presence Detection (SPD) failure
Major
856A
DIMM_D2 encountered a Serial Presence Detection (SPD) failure
Major
856B
DIMM_D3 encountered a Serial Presence Detection (SPD) failure
Major
856C
DIMM_E1 encountered a Serial Presence Detection (SPD) failure
Major
856D
DIMM_E2 encountered a Serial Presence Detection (SPD) failure
Major
856E
DIMM_E3 encountered a Serial Presence Detection (SPD) failure
Major
856F
DIMM_F1 encountered a Serial Presence Detection (SPD) failure
Major
8570
DIMM_F2 encountered a Serial Presence Detection (SPD) failure
Major
8571
DIMM_F3 encountered a Serial Presence Detection (SPD) failure
Major
8572
DIMM_G1 encountered a Serial Presence Detection (SPD) failure
Major
8573
DIMM_G2 encountered a Serial Presence Detection (SPD) failure
Major
8574
DIMM_G3 encountered a Serial Presence Detection (SPD) failure
Major
8575
DIMM_H1 encountered a Serial Presence Detection (SPD) failure
Major
8576
DIMM_H2 encountered a Serial Presence Detection (SPD) failure
Major
8577
DIMM_H3 encountered a Serial Presence Detection (SPD) failure
Major
8578
DIMM_I1 encountered a Serial Presence Detection (SPD) failure
Major
8579
DIMM_I2 encountered a Serial Presence Detection (SPD) failure
Major
857A
DIMM_I3 encountered a Serial Presence Detection (SPD) failure
Major
857B
DIMM_J1 encountered a Serial Presence Detection (SPD) failure
Major
857C
DIMM_J2 encountered a Serial Presence Detection (SPD) failure
Major
857D
DIMM_J3 encountered a Serial Presence Detection (SPD) failure
Major
857E
DIMM_K1 encountered a Serial Presence Detection (SPD) failure
Major
857F
(Go to 85E0)
DIMM_K2 encountered a Serial Presence Detection (SPD) failure
Major
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix E: POST Error Messages and Handling
Revision 1.2 Intel order number G34153-003
159
Error Code
Error Message
Response
85C0
DIMM_K3 failed test/initialization
Major
85C1
DIMM_L1 failed test/initialization
Major
85C2
DIMM_L2 failed test/initialization
Major
85C3
DIMM_L3 failed test/initialization
Major
85C4
DIMM_M1 failed test/initialization
Major
85C5
DIMM_M2 failed test/initialization
Major
85C6
DIMM_M3 failed test/initialization
Major
85C7
DIMM_N1 failed test/initialization
Major
85C8
DIMM_N2 failed test/initialization
Major
85C9
DIMM_N3 failed test/initialization
Major
85CA
DIMM_O1 failed test/initialization
Major
85CB
DIMM_O2 failed test/initialization
Major
85CC
DIMM_O3 failed test/initialization
Major
85CD
DIMM_P1 failed test/initialization
Major
85CE
DIMM_P2 failed test/initialization
Major
85CF
DIMM_P3 failed test/initialization
Major
85D0
DIMM_K3 disabled
Major
85D1
DIMM_L1 disabled
Major
85D2
DIMM_L2 disabled
Major
85D3
DIMM_L3 disabled
Major
85D4
DIMM_M1 disabled
Major
85D5
DIMM_M2 disabled
Major
85D6
DIMM_M3 disabled
Major
85D7
DIMM_N1 disabled
Major
85D8
DIMM_N2 disabled
Major
85D9
DIMM_N3 disabled
Major
85DA
DIMM_O1 disabled
Major
85DB
DIMM_O2 disabled
Major
85DC
DIMM_O3 disabled
Major
85DD
DIMM_P1 disabled
Major
85DE
DIMM_P2 disabled
Major
85DF
DIMM_P3 disabled
Major
85E0
DIMM_K3 encountered a Serial Presence Detection (SPD) failure
Major
85E1
DIMM_L1 encountered a Serial Presence Detection (SPD) failure
Major
85E2
DIMM_L2 encountered a Serial Presence Detection (SPD) failure
Major
85E3
DIMM_L3 encountered a Serial Presence Detection (SPD) failure
Major
85E4
DIMM_M1 encountered a Serial Presence Detection (SPD) failure
Major
85E5
DIMM_M2 encountered a Serial Presence Detection (SPD) failure
Major
85E6
DIMM_M3 encountered a Serial Presence Detection (SPD) failure
Major
85E7
DIMM_N1 encountered a Serial Presence Detection (SPD) failure
Major
85E8
DIMM_N2 encountered a Serial Presence Detection (SPD) failure
Major
85E9
DIMM_N3 encountered a Serial Presence Detection (SPD) failure
Major
85EA
DIMM_O1 encountered a Serial Presence Detection (SPD) failure
Major
85EB
DIMM_O2 encountered a Serial Presence Detection (SPD) failure
Major
85EC
DIMM_O3 encountered a Serial Presence Detection (SPD) failure
Major
Appendix E: POST Error Messages and Handling Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
160
Error Code
Error Message
Response
85ED
DIMM_P1 encountered a Serial Presence Detection (SPD) failure
Major
85EE
DIMM_P2 encountered a Serial Presence Detection (SPD) failure
Major
85EF
DIMM_P3 encountered a Serial Presence Detection (SPD) failure
Major
8604
POST Reclaim of non-critical NVRAM variables
Minor
8605
BIOS Settings are corrupted
Major
8606
NVRAM variable space was corrupted and has been reinitialized
Major
92A3
Serial port component was not detected
Major
92A9
Serial port component encountered a resource conflict error
Major
A000
TPM device not detected.
Minor
A001
TPM device missing or not responding.
Minor
A002
TPM device failure.
Minor
A003
TPM device failed self test.
Minor
A100
BIOS ACM Error
Major
A421
PCI component encountered a SERR error
Fatal
A5A0
PCI Express* component encountered a PERR error
Minor
A5A1
PCI Express* component encountered an SERR error
Fatal
A6A0
DXE Boot Services driver: Not enough memory available to shadow a
Legacy Option ROM.
Minor
POST Error Beep Codes
The following table lists the POST error beep codes. Prior to system video initialization, the
BIOS uses these beep codes to inform users on error conditions. The beep code is followed by
a user-visible code on the POST Progress LEDs
Table 86. POST Error Beep Codes
Beeps
Error Message
POST Progress Code
Description
1
USB device action
NA
Short beep sounded whenever a USB device is discovered
in POST, or inserted or removed during runtime
1 long
Intel® TXT security
violation
0xAE, 0xAF
System halted because Intel® Trusted Execution
Technology detected a potential violation of system
security.
3
Memory error
See Tables 28 and 29
System halted because a fatal error related to the memory
was detected.
2
BIOS Recovery
started
NA
Recovery boot has been initiated
4
BIOS Recovery
failure
NA
BIOS recovery has failed. This typically happens so quickly
after recovery us initiated that it sounds like a 2-4 beep
code.
The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes
are sounded each time the problem is discovered, such as on each power-up attempt, but are
not sounded continuously. Codes that are common across all Intel server boards and systems
that use same generation chipset are listed in the following table. Each digit in the code is
represented by a sequence of beeps whose count is equal to the digit.
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix E: POST Error Messages and Handling
Revision 1.2 Intel order number G34153-003
161
Table 87. Integrated BMC Beep Codes
Code
Reason for Beep
Associated Sensors
1-5-2-1
No CPUs installed or first CPU socket is
empty.
CPU1 socket is empty, or sockets are populated
incorrectly
CPU1 must be populated before CPU2.
1-5-2-4
MSID Mismatch
MSID mismatch occurs if a processor is installed into a
system board that has incompatible power capabilities.
1-5-4-2
Power fault
DC power unexpectedly lost (power good dropout)
Power unit sensors report power unit failure offset
1-5-4-4
Power control fault (power good assertion
timeout).
Power good assertion timeout Power unit sensors
report soft power control failure offset
1-5-1-2
VR Watchdog Timer sensor assertion
VR controller DC power on sequence was not
completed in time.
1-5-1-4
Power Supply Status
The system does not power on or unexpectedly powers
off and a Power Supply Unit (PSU) is present that is an
incompatible model with one or more other PSUs in the
system.
Glossary Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
162
Glossary
This appendix contains important terms used in the preceding chapters. For ease of use, numeric entries
are listed first (for example, 82460GX) with alpha entries following (for example, AGP 4x). Acronyms are
then entered in their respective place, with non-acronyms following.
Term
Definition
ACPI
Advanced Configuration and Power Interface
AP
Application Processor
APIC
Advanced Programmable Interrupt Control
ASIC
Application Specific Integrated Circuit
BIOS
Basic Input/Output System
BIST
Built-In Self Test
BMC
Baseboard Management Controller
Bridge
Circuitry connecting one computer bus to another, allowing an agent on one to access the other
BSP
Bootstrap Processor
byte
8-bit quantity.
CBC
Chassis Bridge Controller (A microcontroller connected to one or more other CBCs, together they
bridge the IPMB buses of multiple chassis.
CEK
Common Enabling Kit
CHAP
Challenge Handshake Authentication Protocol
CMOS
In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes
of memory, which normally resides on the server board.
DPC
Direct Platform Control
EEPROM
Electrically Erasable Programmable Read-Only Memory
EHCI
Enhanced Host Controller Interface
EMP
Emergency Management Port
EPS
External Product Specification
FMB
Flexible Mother Board
FMC
Flex Management Connector
FMM
Flex Management Module
FRB
Fault Resilient Booting
FRU
Field Replaceable Unit
FSB
Front Side Bus
GB
1024MB
GPIO
General Purpose I/O
GTL
Gunning Transceiver Logic
HSC
Hot-Swap Controller
Hz
Hertz (1 cycle/second)
I2C
Inter-Integrated Circuit Bus
IA
Intel® Architecture
IBF
Input Buffer
ICH
I/O Controller Hub
ICMB
Intelligent Chassis Management Bus
IERR
Internal Error
IFB
I/O and Firmware Bridge
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Glossary
Revision 1.2 Intel order number G34153-003
163
Term
Definition
INTR
Interrupt
IP
Internet Protocol
IPMB
Intelligent Platform Management Bus
IPMI
Intelligent Platform Management Interface
IR
Infrared
ITP
In-Target Probe
KB
1024 bytes
KCS
Keyboard Controller Style
LAN
Local Area Network
LCD
Liquid Crystal Display
LED
Light Emitting Diode
LPC
Low Pin Count
LUN
Logical Unit Number
MAC
Media Access Control
MB
1024KB
mBMC
National Semiconductor© PC87431x mini BMC
MCH
Memory Controller Hub
MD2
Message Digest 2 Hashing Algorithm
MD5
Message Digest 5 Hashing Algorithm Higher Security
ms
milliseconds
MTTR
Memory Tpe Range Register
Mux
Multiplexor
NIC
Network Interface Controller
NMI
Nonmaskable Interrupt
OBF
Output Buffer
OEM
Original Equipment Manufacturer
Ohm
Unit of electrical resistance
PEF
Platform Event Filtering
PEP
Platform Event Paging
PIA
Platform Information Area (This feature configures the firmware for the platform hardware)
PLD
Programmable Logic Device
PMI
Platform Management Interrupt
POST
Power-On Self Test
PSMI
Power Supply Management Interface
PWM
Pulse-Width Modulation
RAM
Random Access Memory
RASUM
Reliability, Availability, Serviceability, Usability, and Manageability
RISC
Reduced Instruction Set Computing
ROM
Read Only Memory
RTC
Real-Time Clock (Component of ICH peripheral chip on the server board)
SDR
Sensor Data Record
SECC
Single Edge Connector Cartridge
SEEPROM
Serial Electrically Erasable Programmable Read-Only Memory
SEL
System Event Log
SIO
Server Input/Output
Glossary Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
Intel order number G34153-003 Revision 1.2
164
Term
Definition
SMI
Server Management Interrupt (SMI is the highest priority nonmaskable interrupt)
SMM
Server Management Mode
SMS
Server Management Software
SNMP
Simple Network Management Protocol
TBD
To Be Determined
TIM
Thermal Interface Material
UART
Universal Asynchronous Receiver/Transmitter
UDP
User Datagram Protocol
UHCI
Universal Host Controller Interface
UTC
Universal time coordinare
VID
Voltage Identification
VRD
Voltage Regulator Down
Word
16-bit quantity
ZIF
Zero Insertion Force
Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Reference Documents
Revision 1.2 Intel order number G34153-003
165
Reference Documents
See the following document for additional information:
BIOS for EPSD Platforms Based on Intel® Xeon Processor E5-4600/2600/2400/1600
Product Families External Product Specification
EPSD Platforms Based On Intel Xeon® Processor E5 4600/2600/2400/1600 Product
Families BMC Core Firmware External Product Specification
Intel® Server System P4000IP/CR Technical Product Specification
Intel® Server System R2000IP Technical Product Specification
Intel® Remote Management Module 4 Technical Product Specification
Intelligent Platform Management Interface Specification
SmaRT and CLST Architecture on “Romley” Systems and Power Supplies Specification