C4600A1-0080 OCXO
VECTRON
INTERNATIONAL
www.vectron.com
49-07268-801-281 fax
49-07268-801-0 tel
Germany
D-74924 Neckarbischofsheim
Landstrasse
Vectron International GmbH & Co. KG
modified 2008-07-23 Index : 14 printed 2008-08-20 • page 1 of 4
Vectron International • Product Specifications
Nominal frequency (f0) 10 MHz
Frequency stabilities
Parameter Frequency stability Operating temp. range
vs. operating temp. range (df/f@25 °C) -15 to 15 ppb -40 ... 70 °C
-10 to 10 ppb -20 ... 70 °C
Parameter Value Condition
initial tolerance (df/f0) -95 to 95 ppb @Vc = 2.5 V; 25 °C
vs. supply voltage change (df/f) -1 to 1 ppb static; 5 V ±5 %
vs. load change (df/f) -1 to 1 ppb static; Load ± 10 %
vs. aging / daily (df/f) <± 0.5 ppb after 30 days ; @ 25 °C
vs. aging / month (df/f) <± 20 ppb after 30 days ; @ 25 °C
vs. aging / year (df/f) <± 50 ppb after 30 days ; @ 25 °C
vs. aging / 10 years (df/f) <± 0.4 ppm after 30 days ; @ 25 °C
±200ppb within 90 days after shipment with Vc=2.5V @ 15 min. warm up time ref. to exactly 10MHz
Frequency tuning
Parameter Value Condition
Electrical frequency control (EFC) (df/f0) -1 to -0.5 ppm ext. tuning voltage @ 0 V
0.5 to 1 ppm ext. tuning voltage @ 5 V
Linearity < 10 %
Frequency control input impedance > 100 kOhm
Modulation bandwidth > 1000 Hz @ -3 dB
RF output
Parameter Value Condition
Signal HCMOS
Load 50 pF ±10 %
Fan out 10
Rise Time < 10 ns @ 0.5 to 4.5 V
Fall Time < 10 ns @ 4.5 to 0.5 V
Duty cycle 40 / 60 % @ 2.5 V
V Lo
x < 0.3 V
V High x > 4.5 V
Supply voltage
Parameter Value Condition
Supply voltage (Vs) 5 V ± 5 %
Current consumption steady state < 250 mA @ Vsnom & 25 °C
Current consumption during warm up < 600 mA @ Vs
after 48h oper. +Vc=2.5V Retrace after 24h power off and 1hour power on: ±10ppb
Reference Voltage output
Parameter Value Condition
Reference Voltage 4V ± 5%
Additional Parameters
Parameter Value Condition
Phase Noise < -80 dBc/Hz 1 Hz max
< -120 dBc/Hz 10 Hz values
< -140 dBc/Hz 100 Hz
< -145 dBc/Hz 1 kHz
< -150 dBc/Hz 10 kHz
Short term stability <± 50.0 E-12 1 sec
Warm-up time < 15 min @ 25 °C to final frequency
dditional information
warm up time: within ±10ppb refer. to freq. after 1 hour power on
Processing & Packing handling&processing note