60
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Moisture protection
- Salt spray protection
- Degree of protection: IP 54 / IP 68
Max. 237 m3/h
Type m3/h cfm VDC VDC dB(A) Bel(A) / Watts rpm-1 °C Hours Hours
4182 NGX 160 94 12 6...15 44 5.3 3.7 2 800 -20...+75 85 000 / 37 500 142 500 ¿
4182 NX 180 106 12 6...15 49 5.7 4.9 3 200 -30...+75 85 000 / 37 500 142 500 ¡
4182 NXH 237 140 12 7...14 57 6.5 11.0 4 400 -30...+55 70 000 / 50 000 117 500 ¬
4184 NGX 160 94 24 12...31.5 44 5.3 3.3 2 800 -20...+75 85 000 / 37 500 142 500 ¿
4184 NXM 160 94 24 12...31.5 44 5.3 3.2 2 800 -30...+75 85 000 / 37 500 142 500 ¿
4184 NX 180 106 24 12...31.5 49 5.7 4.9 3 200 -30...+70 85 000 / 42 500 142 500 ¡
4184 NXH 237 140 24 12...28 57 6.5 11.0 4 400 -30...+70 70 000 / 35 000 117 500 ¬
4188 NGX 160 94 48 36...60 44 5.3 3.6 2 800 -20...+75 85 000 / 37 500 142 500 ¿
4188 NXM 160 94 48 36...60 44 5.3 3.5 2 800 -30...+75 85 000 / 37 500 142 500 ¿
Subject to change
Nominal voltage
Air flow
Air flow
Voltage range
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Power consumption
Nominal speed
Temperature range
Service life L10 (40 °C)
ebm-papst standard
Service life L10 (Tmax)
ebm-papst standard
Life expectancy L10IPC
(40 °C) see page 17
Curve
Material: Housing: Die-cast aluminum
Impeller: GRP1) (PA)
Direction of air flow: Intake over struts
Direction of rotation:Clockwise,
looking towards rotor
Connection: On flat connectors, 2.8 x 0.5 mm
Also available with wires as
an option
Highlights: Housing with grounding lug for
screw M4 x 8 (Torx)
Weight: 390 g
1) Fiberglass-reinforced plastic
Finger guards
from p. 242
Cables
P. 255
DC axial fans
119 x 38 mm
Series 4100 N
Nominal data