LPS120 Series
1 of 3
Embedded Power for
Business-Critical Continuity
LPS120 Series
120 Watts
Special Features
• Activepowerfactorcorrection
• 3”x5”footprint
• Lessthan1Uhigh
• EN61000-3-2compliant
• Remotesense
• Powerfailandremoteinhibit
• Singlewirecurrentsharing
• Adjustablemainoutput
• Built-inClassBEMIfilter
• Overvoltageprotection
• Overloadprotection
• Thermaloverloadprotection
• 5VStandbyoutput
and12VFanoutput
Total Power: 80-130Watts
Input Voltage: 85-264VAC
# of Outputs: Single
Electrical Specifications
Safety
Input
Inputrange: 85-264VAC;127-300VDC
Frequency: 47-440Hz
Inrushcurrent: 40Amax.,coldstart@25°C
Efficiency: 80% typical at full load
EMI/RFI: FCCClassBconducted;CISPR22ClassBconducted;EN55022ClassBcon-
ducted;VDE0878PT3ClassBconducted
Powerfactor: 0.99typical
Safetyground
leakagecurrent:
0.5mA@50/60Hz,264VACinput
Output
Maximumpower: 80Wforconvection;130Wwith30CFMforcedair
Adjustmentrange: ±5%minimumonthemainoutputs
Fanoutput: 12V@500mA-5%,+7%
Standbyoutputs: 5V@500mA±5%
Hold-uptime: 20ms@125Wload,120VACinput
Overloadprotection: Shortcircuitprotectiononalloutputs.Caseoverloadprotected@
120-135%aboverating
Overvoltageprotection: 20-35%abovenominaloutput
Remotesense: Compensatesfor0.5Vleaddropmax.Willoperatewithoutremotesense
connected.Reverseconnectionprotected.
LogicalControl
Powerfailure: TTLlogicsignalgoeshigh100-500msecaftermainoutput;itgoeslowat
least4msecbeforelossofregulation
Remoteinhibit: Requiresacontactclosuretodisabletheoutputs,except5Vstandby.
Remotesense: Compensatesfor0.5Vleaddropmin.Willoperatewithoutremotesense
connected.Reverseconnectionprotected.
TUV: 60950
UL: 60950
CSA 60950
NEMKO: 60950
AUSTEL: 60950
CB: Certificate and report
CE: Mark(LVD)
Embedded Power for
Business-Critical Continuity
MechanicalDrawing
Rev. 09.15.09_128
LPS120 Series
2 of 3
2.55
(64.8)
5.00
(127.0)
4.55
(115.6)
1.29
(32.8)
0.20" (5)
SK1
610
SK3
15
SK2
LIVE
NEUTRAL
EARTH
P1
1
2
3.00
(76.2)
SK3
0.15" DIA. 4 places
(4.0)
M3.5 (2 places)
V
Adjust
POT
Operatingtemperature: 0°to50°Cambientderateeach
outputas2.5%perdegreefrom
50°to70°C.-20°Cstartup
Storagetemperature: -40°Cto+85°C
Electromagnetic
susceptibility:
DesignedtomeetEN61000-4;
-2,-3,-4,-5,-6,-8,-11Level3
Humidity: Operating;non-condensing
10%to95%RH
Vibration: IEC68-2-6tothelevelsof
IEC721-3-2
MTBFdemonstrated >550,000hoursatfullloadand
25°Cambientconditions
EnvironmentalSpecifications
Connector LPS120
SK1 Pin1 Neutral
Pin3 Line
SK2 TB-1 COMMON
TB-2 Mainoutput
SK3 Pin1 +V1Remotesense
Pin2 -V1Remotesense
Pin3 +Remoteinhibit
Pin4 -Remoteinhibit
Pin5 +Powerfail
Pin6 Common
Pin7 SWP
Pin8 +12V
Pin9 12Vcommon
Pin10 +5Vstandby
Mating Connectors
(SK1)ACInput: Molex09-50-8031(connector)08-52-0113(pins)
(SK2)DCOutput: Molexseries19141-0058/0063Spadelug
(SK3)ControlSignals:
Molex90142-0010(USA)
PINS:90119-2110or
Amp:87977-3
PINS:87309-8
EmersonNetworkPowerConnectorKit#70-841-020,includesalloftheabove.
Rev. 09.15.09_12
LPS120 Series
3 of 3
Embedded Power for
Business-Critical Continuity
OrderingInformation
Model
Number
Output
Voltage
Minimum
Load
Maximum Load
with Convection
Cooling
Maximum Load
with 30CFM
Forced Air
Peak Load Regulation2
Ripple
P/P
(PARD)3
LPS121 3.3V 0A 21A 36A 29A ± 2% 50mV
LPS122 5V 0A 16A 26A 29A ± 2% 50mV
LPS123 12V 0A 6.7A 10.8A 12.8A ± 2% 120mV
LPS124 15V 0A 5.3A 8.7A 10.0A ± 2% 150mV
LPS125 24V 0A 3.4A 5.4A 6.3A ± 2% 240mV
LPS128 48V 0A 1.7A 2.7A 3.2A ± 2% 480mV
1. Peakcurrentlasting<30secondswithamaximum10%dutycycle.
2. At25°Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings.
3. Peak-to-peakwith20MHzbandwidthand10µF(tantalumcapacitor)inparallelwitha0.1µFcapacitoratratedlinevolt-
ageandloadranges.
4. Wheninparallela10%loadisrequiredforeachpowersupply.
Notes:
1. Specificationssubjecttochangewithoutnotice.
2. Alldimensionsininches(mm),toleranceis±.02”.
3. mountingholesMH1,MH2,MH3shouldbegroundedfor
EMIpurpose
4. MountingMH1issafetygroundconnection
5. Specificationsareforconvectionratingatfactorysettings
at115VACinput25°Cunlessotherwisestated.
6.Thispowersupplyrequiresmountingonmetalstandoffs
0.20”(5m)inheight.
7. Warranty:2year
8. Weight:0.71lb./0.32kg
PinAssignments
Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone:+17609304600
Facsimile: +17609300698
Europe (UK)
Waterfront Business Park
MerryHill,Dudley
WestMidlands,DY51LX
UnitedKingdom
Telephone:+44(0)1384842211
Facsimile: +44(0)1384843355
Asia (HK)
14/F,LuPlaza
2WingYipStreet
KwunTong,Kowloon
HongKong
Telephone:+85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.PowerConversion.com
techsupport.embeddedpower
@emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
informationorforanyerrorsoromissions.
EmersonNetworkPowerandtheEmerson
NetworkPowerlogoaretrademarksand
servicemarksofEmersonElectricCo.
©2009EmersonElectricCo.
EmersonNetworkPower.com
EmbeddedComputing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
PrecisionCooling
Racks&IntegratedCabinets
Services
SurgeProtection
Emerson Network Power.
Thegloballeaderinenabling
business-criticalcontinuity.
ACPower
Connectivity
DCPower