FTRX-1611-3 40km XFP Product Specification – March 2006 F i n i s a r
© Finisar Corporation 23-March-06 Rev B2 Page 4
III. Electrical Characteristics (TOP = -5 to 70 °C, VCC5 = 4.75 to 5.25 Volts)
Parameter Symbol Min Typ Max Unit Ref.
Main Supply Voltage Vcc5 4.75 5.25 V
Supply Volt ag e #2 Vcc3 3.13 3.45 V
Supply Volt ag e #3 Vcc2 1.71 1.89 V
Supply Current – Vcc5 supply Icc5 350 mA
Supply Current – Vcc3 supply Icc3 400 mA
Supply Current – Vcc2 supply Icc2 750 mA
Module total power P 3.5 W 1
Transmitter
Input differential impedance Rin 100 Ω 2
Differential data input swing Vin,pp 120 820 mV
Transmit Disable Voltage VD 2.0 Vcc V 3
Transmit Enable Voltage VEN GND GND+ 0.8 V
Transmit Disable Assert Time 10 us
Receiver
Differential data output swing Vout,pp 340 650 850 mV 4
Data output rise time tr 38 ps 5
Data output fall time tf 38 ps 5
LOS Fault VLOS fault Vcc – 0.5 VccHOST V 6
LOS Normal VLOS norm GND GND+0.5 V 6
Power Supply Rejection PSR See Note 6 below 7
Reference Clock
Clock differential input impedance Rclkin 100 Ω
Reference Clock frequency f0 Baud/64 MHz
Differential clock input swing Vclkin,pp 640 1600 mV
Clock output rise/fall time trf 200 1250 ps 5
Reference clock frequency tolerance Df -100 +100 PPM
Notes:
1. Maximum total power value is specified across the full temperature and voltage range.
2. After internal AC coupling.
3. Or open circuit.
4. Into 100 ohms differential termination.
5. 20 – 80 %
6. Loss Of Signal is open collector to be pulled up with a 4.7k – 10kohm resistor to 3.15 – 3.6V. Logic 0
indicates normal operation; logic 1 indicates no signal detected.
7. Per Section 2.7.1. in the XFP MSA Specification1.