I-25
PRESSURE SWITCHES
Visit www.GemsSensors.com for most current information.
ø1.10˝
(ø28)
ø1.25˝
(ø32)
3/32˝ or
1/8˝ ALLEN
WRENCH
ADJUSTMENT
SCREW
RED, NO.
GREEN, NC.
BLACK, COM.
1.10˝
(28)
DIN
43650A
1.95˝
(50)
DIN 43650A – MALE HALF ONLY
2.20˝
(56)
INGRESS PROTECTION OPTION (IP66)
WITH FLYING LEADS FACTORY SET ONLY
1.58˝
(40)
PRESSURE
PORT
FLYING LEAD
SPDT Shown
with cable clamp
PS82 – Economical
Miniature Vacuum Switches
5˝ to 28˝ Hg (169 to 948 mbar)
These miniature vacuum switches, based on our proven PS71 series, are designed for
demanding applications where space and/or price are strong concerns.
Specifications
Switch SPST; SPDT
Repeatability See Table 1
Wetted Parts
Diaphragm Material Nitrile standard (optional EPDM, Viton® and Neoprene)
Fitting Brass (optional 316 Stainless Steel)
Spring 316 Stainless Steel
Electrical Termination DIN 43650A IP65; Male Conduit with Flying Leads IP65;
Flying Leads IP00; IP option IP66
Proof Pressure 0 psia to 350 psig (-1 bar to 24 bar)
Burst Pressure 700 psi (48 bar)
Approvals CE
Weight, Approximate Brass: 0.4 lbs. (0.18 kg)
Dimensions
Options Selected AC DC
No option or -RD 5 amps @ 125/250 Volts 5 amps resistive,
3 amps inductive @ 28 Volts
-G only or -RD with -G 1 amp @ 125 Volts 1 amp resistive,
0.5 amp inductive @ 28 Volts
-10A only or -SP without -G 10.1 amps @ 125/250 Volts
-SP with -G 2 amps @ 125/250 Volts
Electrical Switch Ratings
Options Selected
Diaphragm Material No option,
-10A, -SP or -RD -RD or -RD and -G -SP or -10A
Nitrile 15°F to 185°F
(-9°C to +85°C)
15°F to 250°F
(-9°C to +121°C)
15°F to 212°F
(-9°C to +100°C)
Viton®0°F to 185°F
(-18°C to +85°C)
0°F to 250°F
(-18°C to +121°C)
0°F to 212°F
(-18°C to +100°C)
EPDM -10°F to +185°F
(-23°C to +85°C)
-10°F to +250°F
(-23°C to +121°C)
-10°F to +212°F
(-23°C to +100°C)
Neoprene -10°F to +185°F
(-23°C to +85°C)
-10°F to +250°F
(-23°C to +121°C)
-10°F to +212°F
(-23°C to +100°C)
Note: Switches may function below the cold temperature limit but the set points and deadband will increase.
Consult factory for details.
Recommended Operating Temperature Limits
I-26
PRESSURE SWITCHES
Visit www.GemsSensors.com for most current information.
Notes:
1. Other fittings available.
Consult factory.
2. 18˝ is standard. Specify lead
length in inches (max. 48˝).
e.g. -FL18 or -FLS30.
3. 18˝ is standard. Specify
lead length in inches (max.
48˝). e.g. -EL18 or -EL30.
4. 36˝ is minimum. Specify
cable length in inches.
e.g. -CAB36 or -CAB120.
5. DIN connectors require -C
SPDT circuit.
6. Requires -10A, -G options
(50% increase in deadband
typical).
7. Options -10A, -G or -RD
cannot be combined.
8. Ingress Protection is
available only with -FL, -FLS,
-ELS or -CAB Electrical
Termination choices.
Ingress Protection requires
Fixed Set Point -FS.
9. Set Point must be within
Pressure Range selected in
Step 1.
1 Pressure Range Code
Insert Pressure Range Code from Table 1, below.
2 Pressure Fitting1
Brass
-2MNB = 1/8˝ NPTM
-4MNB = 1/4˝ NPTM
-2MGB = 1/8˝ BSPM (G type)
-4MGB = 1/4˝ BSPM (G type)
-4MSB = 7/16˝-20 SAE Male
-6MSB = 9/16˝-18 SAE Male
316 Stainless Steel
-2MNS = 1/8˝ NPTM
-4MNS = 1/4˝ NPTM
-4MGS = 1/4˝ BSPM (G type)
3 Circuit
-A = SPST/N.O.
-B = SPST/N.C.
-C = SPDT
4 Electrical Termination
-FLXX = Flying Leads2
-FLSXX = Flying Leads w/PVC Shrink Tubing2
-ELXX = 1/2˝ NPT Male Conduit w/Flying Leads3
-CABXX = 18 AWG PVC Cable4
-H = DIN 43650A Male Half Only5
-HR = Right Angle DIN 43650A Male Half Only5
-HC = DIN 43650A 9mm Cable Clamp5
-HCR = Right Angle DIN 43650A 9mm Cable
Clamp5
-HN = DIN 43650A with 1/2˝ Female NPT Conduit5
-HNR = Right Angle DIN 43650A with 1/2˝ Female
NPT Conduit5
-HM = Micro (9.4mm Spacing) DIN Style Male
Half Only5
-SP = Spade Terminals6
5 Options
-10A = 10A @ 125/250 VAC Max. Rating7
-V = Viton® Diaphragm
-N = Neoprene Diaphragm
-E = EPDM Diaphragm
-G = Gold Contacts
(for loads less than 12 mA @ 12 VDC)
-RD = Reduced Differential
(25% reduction typical)
-IP = Ingress Protection8
-OXY = Oxygen Cleaned
-WF = Weather Pack Connector, Female
-WM = Weather Pack Connector, Male
-DE = Deutsch Connector, Male, DT04 Series
6 Fixed Set Point (optional)
A. Specify set point -FS
(in Inches Hg or mBAR, see example)9
B. Set Point Actuation
R on Rising Vacuum
F on Falling Vacuum
Example: -FS300MBARF for 300 mBAR Falling
or -FS10INHGR for 10˝ Hg Rising
vaCUUm SWITCHES
Vacuum Range Code Vacuum Range Repeatability Average Deadband*
10 5-15” Hg (169-508 mbar) ±0.71” Hg (24 mbar) +2% of setting 3.05” Hg (103 mbar) +7% of setting
20 12-28” Hg (406-948mbar) ±1.63” Hg (55 mbar) +2% of setting 6.1” Hg (207 mbar) +8% of setting
* -IP and -EL options are approximate gauge switches. Altitude and temperature changes will result in set point shifts.
Table 1 — Vacuum Range Codes
The deadband values tabulated are for the standard microswitch. With either the -SP of -10A option, the deadband
values are typically 50% greater than those listed. With the -RD option, the values will be typically 25% less than
those listed. In certain applications deadband can be tailored and controlled to customer specifications. Consult
factory for details.
PS82 -10 -4MNB -C -H -XX -XXXX
1 2 3 4 5 6
How To Order
Use the Bold characters from the chart below to construct a product code. Please reference Notes.