Product leaflet Single phase electricity meters A41 and A42 EQ meters in Bronze version from ABB The compact and versatile EQ meters A41 and A42 are single phase meters with full four quadrants measuring meaning both active/reactive energy measurements and import/export of energy. They can be used in most of the common applications for reliable and trustworthy metering of energy usage. EQ meters A41 and A42 in Bronze version can be used in stand-alone applications or metering network installations with the option of inbuilt M-Bus or Modbus. General features The A series meters are ideal for many applications and installations. The meters support a wide voltage range as well as a wide temperature range. The display is pixel-oriented and can display up to four quantities at the same time. Navigating the meter is easily done via the push-buttons below the display. To configure the meter settings, the set button must be accessed and this button is protected against unauthorized use when the transparent lid on the front of the meter is closed and sealed. The power consumption of the meter is very low, less than 0.8 VA, makes them economical in the long run - an important feature especially for large meter populations. Communication Data from A41 and A42 in Bronze version can be collected via pulse output or serial communication. The meters are equipped with a transistor output for 5-40 VDC external supply. It can be used for pulses proportionally to the measured energy or various alarms. The meters are also available with built-in serial communication interfaces for Modbus RTU (RS-485) or M-Bus as options. Import and export measurements B21 Bronze version measures the energy flowing both in (imported) and out (exported) through the meter and saves the energy in separate registers. Approvals The A41 and A42 meters are type approved according to IEC as well as type approved and verified according to MID. MID is the Measure Instruments Directive 2004/22/EC from European Commission. The type approval is according to stan- dards that covers all relevant technical aspects of the meter. These include climate conditions, electromagnetic compatibility (EMC), electrical requirements, mechanical requirements and accuracy. Instrumentation The A41 and A42 meters in Bronze version support reading of instrument values. A large number of electrical properties can be read. * * * * * * * Active power - Total and per phase Reactive power - Total and per phase Apparent power - Total and per phase Current Voltage Power factor Frequency Ordering details 80 A direct connected, 4 DIN Voltage V Communication Type Order code Weight 1 pc Bronze Active and reactive energy, import/export, pulse output, class B (Cl. 1), reactive Cl.2. 57.7...288 V AC RS-485 A41 212 - 100 2CMA170501R1000 0.23 Order code Weight 1 pc 6 A transformer CTVT connected, 4 DIN Voltage V Communication Type Bronze Active and reactive energy, import/export, pulse output, class B (Cl. 1), reactive Cl.2. 57.7...288 V AC RS-485 A42 212 - 100 2CMA170511R1000 0.20 A series Technical data Resistance to water and dust Mechanical environment Electromagnetic environment Outputs Current Voltage Pulse output frequency Pulse length Terminal wire area Recommended tightening torque EMC compatibility Impulse voltage test Surge voltage test Fast transient burst test Immunity to electromagnetic HF-fields Immunity to conducted disturbance Immunity to disturbance with harmonics Radio frequency emission Electrostatic discharge Standards 1 0.001 VA (0.001 W) at 230 V AC and Ib 1A 0.05 A 6A 0.02 A < 1 mA 0.5 - 10 mm2 1.5 Nm Dimensions Width Height Depth DIN modules 6 L N A42 1 2 3 5 S1 S2 P1 P2 P1 L1 N 1000 imp/kWh 40 ms 5000 imp/kWh 97 1/999 - 999999/1 1/9 - 9999/1 B (Cl. 1), C (Cl. 0.5 S) or reactive Cl. 2 0.5 %, 1% 45 Dimensions - 70 43 58 65 -40C - +70C -40C - +85C 75% yearly average, 95% on 30 days/year Terminal 960 C, cover 650C (IEC 60695-2-1) IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC 60529. Class M2 in accordance with the Measuring Instrument Directive (MID). (2004/22/EC). Class E2 in accordance with the Measuring Instrument Directive (MID), (2004/22/EC). 2 - 100 mA 5 - 240 V AC/DC. For meters with only 1 output, 5 - 40 V DC. Programmable: 1 - 999999 imp/kWh Programmable: 10 - 990 ms 0.5 - 1 mm2 0.25 Nm 6 kV 1.2/50s (IEC 60060-1) 4 kV 1.2/50s (IEC 61000-4-5) 4 kV (IEC 61000-4-4) 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3) 150 kHz - 80 MHz (IEC 61000-4-6) 2 kHz - 150 kHz EN 55022, class B (CISPR22) 15 kV (IEC 61000-4-2) IEC 62052-11, IEC 62053-21 class 1& 2, IEC 62053-22 class 0.5 S, IEC 62053-23 class 2, IEC 62054-21, GB/T 17215.211-2006, GB/T 17215.321-2008 class 1 & 2, GB/T 17215.322-2008, EN 50470-1, EN 50470-3 category A, B and C. Mechanical Material 3 4 Polycarbonate in transparent front glass, bottom case, upper case and terminal cover. Glass reinforced polycarbonate in polycarbonate in terminal cover. 70 mm 97 mm 65 mm 4 ABB AB Meters Low Voltage Products Box 1005 S-61129 Nykoping, Sweden Phone +46 155 29 50 00 www.abb.com/lowvoltage (c) Copyright 2014 ABB. All rights reserved. Specification subject to change without notice. To get more information, install QR code reader on your mobile device, scan the code and see more. Product leaflet 2CMC484001L0201. Rev. A, October 2014. Prod. ABB AB, Low Voltage Products A41 0.5 - 1 mm2 0.25 Nm 50 or 60 Hz 5% B (Cl. 1) and reactive Cl. 2 1% Pixel oriented Wiring diagram 89 230 V AC 57.7 ... 288 VAC (-20% - +15%) 0.8 VA (0.8 W) total 0.007 VA (0.007 W) at 230 V AC and Ib 5A 5A 0.5 A 80 A 0.25 A < 20 mA 1 - 25 mm2 3 Nm A42 93 A41 Voltage/current inputs Nominal voltage Voltage range Power dissipation voltage circuits Power dissipation current circuits Base current Ib Rated current In Reference current Iref Transitional current Itr Maximum current Imax Minimum current Imin Starting current Ist Terminal wire area Recommended tightening torque Communication Terminal wire area Recommended tightening torque Transformer ratios Configurable current ratio (VT) Configurable current ratio (CT) Pulse indicator (LED) Pulse frequency Pulse length General data Frequency Accuracy Class Active energy Display of energy Environmental Operating temperature Storage temperature Humidity Resistance to fire and heat