Q1F-1150V48
Q1F-2150V123
Q1F-2150V125
Q1H-5060V
Q1I-1060V12
Q1I-2050V53
Q1I-2060V123
Q1I-2060V125
Q1J-1050V-5
Q1J-1060V-12
Q1J-1060V24
Q1J-1060V48
Q1K-5150V
Q1K-5200V
Q1L-5060V
RH1E-1067V
* TEMPERATURE RANGE:OPERATING 0℃~70℃ (18~36VDC); NON-
OPERATING TEMPERATURE: -20℃~80℃
* HOLD UP TIME:2mS MINIMUM AT 10V FULL LOAD (DC18V)
* LEAKAGE CURRENT: 3.5MA MAX. AT NOMINAL VOLTAGE 36VDC
* DIELECTRIC WITHSTAND:INPUT/OUTPUT 1800 VAC FOR 1 SECOND INPUT
TO FRAME GROUND 1800 VAC FOR 1 SECOND
* EFFICIENCY:82%(+/-2%) AT 18VDC/24VDC IN AND LOAD CONDITION;
12V/6.12A; 5V/4.98A; 3.3V/4.27A; -12V/0.39A; 5VSB/0.56A
* OVER POWER PROTECTION: 110~160% MAX
* OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.6~6.5V,
+12V→13.2~15V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* SAFETY : TO MEET UL, CUL, TUV, CCC
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT
LLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL
SSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-
REGULATIONS.
Pa
e 2 of 2ZIPPY -
11/29/2012http://www.zipp