For more Information
please call
1-800-Belden1
General Description:
14 AWG stranded (41x30) tinned copper conductor, PVC insulation. Rated 105ºC, 600V. Rated 2500V
peak for electronic circuits, and internal wiring of electronic and electrical equipment.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors AWG Stranding Conductor Material
114 41x30 TC - Tinned Copper
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm) Min. Avg. Wall (mm)
PVC - Polyvinyl Chloride 0.826 0.762
Overall Insulation
Overall Cable
Overall Nominal Diameter: 3.505 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +105°C
Bulk Cable Weight: 28.276 Kg/Km
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
UL Rating: 600 V, 105°C
UL Type: MTW or TW
CSA Rating: 600 V, 105°C
CSA Type: AWM I A/B or TEW
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 07/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: VW-1
CSA Flame Test: FT1
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8916 Hook-up/Lead - UL AWM Style 1015
Electrical Characteristics (Overall)
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
7.874
Max. Operating Voltage - UL:
Voltage
600 VRMS
Max. Recommended Current:
Description Current
Single conductor in free air @ 30C ambient. 39 amps
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
8916 001100 30 MT 1.225 KG BROWN 14 STR PVC BRN
8916 0014000 1,219 MT 36.288 KG BROWN C P 14 STR PVC BRN
8916 001500 152 MT 4.763 KG BROWN 14 STR PVC BRN
8916 002100 30 MT 1.225 KG RED 14 STR PVC RED
8916 0024000 1,219 MT 36.288 KG RED C P 14 STR PVC RED
8916 002500 152 MT 4.763 KG RED 14 STR PVC RED
8916 003100 30 MT 1.225 KG ORANGE 14 STR PVC ORG
8916 003500 152 MT 4.763 KG ORANGE 14 STR PVC ORG
8916 004100 30 MT 1.225 KG YELLOW 14 STR PVC YEL
8916 004500 152 MT 4.763 KG YELLOW 14 STR PVC YEL
8916 005100 30 MT 1.225 KG GREEN, DARK 14 STR PVC D GRN
8916 0054000 1,219 MT 36.288 KG GREEN, DARK C P 14 STR PVC DGRN
8916 005500 152 MT 4.763 KG GREEN, DARK 14 STR PVC D GRN
8916 007500 152 MT 4.763 KG VIOLET P #14 STR PVC VIO
8916 008500 152 MT 4.763 KG GRAY P #14 STR PVC GRY
8916 009100 30 MT 1.225 KG WHITE 14 STR PVC WHT
8916 009500 152 MT 4.763 KG WHITE 14 STR PVC WHT
8916 010100 30 MT 1.225 KG BLACK 14 STR PVC BLK
8916 0104000 1,219 MT 36.288 KG BLACK C #14 STR PVC BLK
8916 010500 152 MT 4.763 KG BLACK 14 STR PVC BLK
8916 013100 30 MT 1.225 KG BLUE, DARK 14 STR PVC D BLU
8916 013500 152 MT 4.763 KG BLUE, DARK 14 STR PVC D BLU
8916 189100 30 MT 1.225 KG GREEN/YELLOW A 14 STR PVC GRN/YEL
8916 189500 152 MT 4.763 KG GREEN/YELLOW A 14 STR PVC GRN/YEL
Notes:
A = STOCKED STRIPE COLORS.
C = CRATE REEL PUT-UP.
P = STRIPE COLORS ON STOCK SOLID COLORS. STRIPING ADDER OF $8.00/M' FOR1 OR 2 STRIPES. 10000' MINIMUM ORDER FOR COLOR
COMBINATION.PUT-UP WILL BE SUBJECT TO TWO PIECES (+ OR -) 10% PER SPOOL
Revision Number: 1 Revision Date: 04-23-2013
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8916 Hook-up/Lead - UL AWM Style 1015
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8916 Hook-up/Lead - UL AWM Style 1015