MVAD065 Series
65W 2" x 4" AC-DC Power Supply Converter
MVAD065.B01 Page 2 of 7
power.murata.com
ENVIRONMENTAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Storage Temperature Range -40 85
°C
Operating Temperature Range See thermal derating curves -10 70
Start up -20
Operating Humidity Non-condensing 10 95 %
Operating Altitude For Class I ITE Equipment deployment -200 5000 m
Other -200 2000
MTBF Telcordia SR-332 M1C3 25°C 1M Hours
Shock
Operating, IEC60068-2-27, half-sine 5G, 6ms,
3 times per face, 6 faces Complies
Non-operating, IEC60068-2-27, half-sine,
30G, 18ms, 3 times per face, 6 faces Complies
Vibration
Operating, IEC60068-2-6, 1.0G, 10-150Hz, 10
minutes per axis, on all 3 axes Complies
Non-operating, IEC60068-2-6, 2.0G,
10-150Hz, 10 minutes per axis, on all 3 axes Complies
Safety
IEC60950-1:2005 (2nd Edition); Am1:2009
UL60950-1 2nd Edition,2011-12-19, CSA C22.2 No. 60950-1-07, 2nd Edition,2011-12
EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011
IEC60601-1:2005 + CORR.1(2006) + CORR.2(2007)
ANSI/AAMI ES60601-1 (2005+C1:09 + A2:10), CSA-C22.2 No. 60601-1(2008), MOPP
CE Marking per LVD
Warranty 2 years
Outside Dimensions 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm)
Weight
MVAD065-05 / MVAD065-18 0.285lbs (130g) typical
Other 0.27lbs (123g) typical
PROTECTION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Overvoltage Protection MVAD065-05 Latching (50% load) 110 190 %V1
Other Latching (60% load) 110 160
Overcurrent Protection Hiccup mode 110 160 %A
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation
Primary to Earth Ground (1xMOPP) 1500 Vac
Primary to Secondary (2xMOPP)44000
Secondary to Earth Ground 500 Vdc
Leakage Current (under normal conditions) 240Vac, 60Hz, 25°C 300
µA264Vac, 60Hz, 25°C 350
Touch Current 264Vac, 60Hz, 25°C 100
EMISSIONS AND IMMUNITY
Characteristic Standard Compliance
Input Current Harmonics IEC/EN 61000-3-2 Class A
Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies
Conducted Emissions EN 55022 Class B, Class A (at Class II equipment)
FCC Part 15 Class B, Class A (at Class II equipment)
ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion A
Radiated Field Immunity IEC/EN 61000-4-3 Level 2, Criterion A
Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 3, Criterion A
Surge Immunity IEC/EN 61000-4-5 Level 4, Criterion A
RF Conducted Immunity IEC/EN 61000-4-6 Level 2, Criterion A
Magnetic Field Immunity IEC/EN 61000-4-8 Level 2, Criterion A
Voltage dips, interruptions IEC/EN 61000-4-11 Level 3, Criterion B
4. At class I equipment.