TECHNICAL DATA
Switching difference 12.6 °F ± 7 °F tolerance (7 K ± 4 K)
Sensor element thermostatic bimetal
Contact type snap-action contact
Service life > 100,000 cycles
Max. switching capacity 15 A resistive / 2 A inductive @ AC 120 V
10 A resistive / 2 A inductive @ AC 250 V
DC 30 W (DC 24-72 V)
Max. inrush current AC 16 A for 10 sec.
Connection 2-pole terminal, clamping torque 0.5 Nm max.:
solid wire - AWG 14 max. (2.5 mm²)
stranded wire1 - AWG 16 max. (1.5 mm²)
Housing plastic, UL 94V-0, light grey
Mounting clip for 35 mm DIN rail, EN 60715
Mounting position vertical
Operating / Storage temperature -49 to +176 °F (-45 to +80 °C)
Operating / Storage humidity max. 95 %RH (non-condensing)
Dimensions 2.4 x 1.3 x 1.7” (60 x 33 x 43 mm)
Weight approx. 1.4 oz. (40 g)
Protection type IP20
¹ When connecting with stranded wires, wire end ferrules must be used.
Important note: The contact system of the regulator is subjected to environmental influences, thus the contact resistance
may change. This can lead to a voltage drop and / or self-heating of the contacts.
Thermostat (NC): Thermostat opens on temperature rise – for regulating heaters or for switching signal devices.
Comes with red temperature dial.
Thermostat (NO): Thermostat closes on temperature rise – for regulating filter fans and heat exchangers or for
switching signal devices. Comes with blue temperature dial.
> Compact design
> Wide adjustment range
> Color coded temperature dials
> DIN rail mountable
Enclosure heater
Filter fan, cooling equipment, signal device
SMALL THERMOSTAT
KTO 011 / KTS 011
Setting range Part No. (NC) Part No. (NO) Approvals
+32 to +140 °F 01140.9-00 01141.9-00 VDE UL File No. E164102 CSA EAC
0 to +60 °C 01146.9-00 01147.9-00 VDE UL File No. E164102 CSA EAC
-10 to +50 °C 01142.0-00 01143.0-00 VDE UL File No. E164102 - EAC
+14 to +122 °F 01142.9-00 01143.9-00 VDE UL File No. E164102 CSA EAC
+10 to +70 °C N/A 01149.9-00 VDE UL File No. E164102 - EAC
-15 to +45 °C 01157.0-00 01156.0-00 VDE UL File No. E164102 - EAC
+20 to +80 °C 01159.0-00 01158.0-00 VDE UL File No. E164102 CSA EAC
NO (blue)NC (red)
HeaterThermostat
KTO 011
Thermostat
KTS 011
e.g. Fan Thermostat
KTS 011
e.g. Signal Device
Wiring
examples
www.stegousa.com08.08.2014 | Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application.