0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector FH62 Series Dimension diagram : 35 pos. 11.9 6mm (35 p os.) 1.1mm 4.0mm Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. 0.9mm (width) 0.5mm (guide) Fig.1 Single action lock [Before mating] Features 1Space-saving design Space saving design with 0.25mm pitch, 4.0mm width. (Fig.1) 2Automatic single action lock design Easy to use single action lock design by simply inserting FPC after mounting. (Fig.2) (Release the lock by operating or opening the lock lever when removing FPC.) Operation of the lock lever is not required at the time of mating FPC. Can be operated with one hand. Operation of the lock lever is not required at the time of mating FPC. Contributes to assembly time reduction. Operation of the lock lever is not required at the time of mating FPC. Lock lever will not be damaged by operation. Operation of the lock lever is not required at the time of mating FPC. No lever at insertion eliminates failures due to FPC movement during locking. [After mating] Just insert it! Fig.2 High FPC retention force through the lock design [FPC being inserted] 3High FPC retention force [FPC inserted] The notches on both sides of FPC are held by the lock lever, generating a high FPC retention force in spite of the small size. (Fig.3) 4Easy FPC insertion Wide guide for easy FPC insertion easy. (Fig.1) 5Supports 0.3mm-thick FPC The design accommodates a rigid 0.3mm-thick FPC, which helps to prevent deformation of the FPC upon insertion. 6Supports high speed transmission Supports high speed transmission with excellent impedance properties. By making a differential pair with the same type of contacts (even number-even number of contacts, odd number-odd-number of contacts) excellent transmission characteristics are achieved, supporting eDP (ver1.4), MIPI (D-PHY) and USB3.0 standards. (Fig.4) Disengagement prevention! Fig.3 Supports high speed transmission (Differential impedance) 130ps rise time (20-80%) 7Environmental Halogen free *As defined by IEC 61249-2-21. Br : 900ppm max, Cl : 900ppm max, BrCl : 1,500ppm max Fig.4 In cases where the application will demand a high level of reliability, such as automotive, please contact a company representative for further information. 2017.9 1 FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector Product Specifications Rated current 0.25A Rating Rated voltage Adaptive FPC/FFC contact specifications -55c to +85C (Note 1) Storage temperature range -10c to +50C (Note 2) humidity 90% max. Operating humidity range Relative (No condensation) Storage humidity range Relative humidity 90% max. (No condensation) Thickness : = 0.30.03mm Gold plated contact traces Item Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. 30V AC/DC Operating temperature range Specification Conditions 1. Insulation resistance 50o min. 100V DC 2. Withstanding voltage No flashover or insulation breakdown 90V AC rms / 1 minute 3. Contact resistance 100mo max. * Including FPC conductor resistance 1mA (AC) 4. Durability (insertion / withdrawal) Contact resistance : 100mo max. No damage, cracks, or parts dislocation 10 cycles 5. Vibration No electrical discontinuity of 1s or more Contact resistance : 100mo max. No damage, cracks, or parts dislocation Frequency : 10 to 55Hz, single amplitude of 0.75mm, 10 cycles in each of the 3 directions 6. Shock No electrical discontinuity of 1s or more Contact resistance : 100mo max. No damage, cracks, or parts dislocation Acceleration of 981m/s2, duration of 6ms, sine half-wave waveform, 3 cycles in each of the 3 axes 7. Humidity (Steady state) Contact resistance : 100mo max. Insulation resistance : 50Mo min. No damage, cracks, or parts dislocation 96 hours at temperature of 40c and humidity of 90% to 95% 8. Temperature cycle Contact resistance : 100mo max. Insulation resistance : 50Mo min. No damage, cracks, or parts dislocation Temperature: -55C / +15c to +35c / +85c / +15c to +35c Time : 30 / 2 to 3 / 30 / 2 to 3 (Minutes) 5 cycles 9. Resistance to soldering heat No deformation of components affecting performance Reflow : See recommended temperature profile (Page 8) Manual soldering: 350 10C for 5 seconds Note 1 : Includes temperature rise caused by current flow. Note 2 : The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and Humidity Range covers non-conducting condition of installed connectors in storage, shipment or during transportation. Materials / Finish Part Insulator Contacts Material Color / Finish LCP Polyamide Copper alloy Beige Black Gold plated Product Number Structure Refer to the chart below when datermining the product specifications from the product number. Please select from the product numbers listed in this catalog when placing orders. FH 62 - 35S - 0.25 SHW (10) Series nameFH Series o 62 Number of contacts35 Contact pitch0.25mm 2 Termination type SHW SMT Horizontal staggered array mounting type Specifications (10)Standard (5,000pcs/reel) (99)500pcs/reel Remarks UL94V-0 ------ FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector Connector Dimensions A0.15 Cavity No. Connect No.2 (0.22) 0.50.1 0.50.1 Lot No. Polarity mark Number of contacts ) (180 Contact No.1 (0.22) (0.22) (3.69) 0.50.1 HRS mark (Pickup area) (2.61) 3.710.1 0.290.1 B0.15 (0.25) (2.05) 1.10.1 (E) 1.0150.1 7 Figure -1 4 0.1 (2.6) (1.25) (0.8) (0.68) (0.34) 0.310.1 2.510.1 FPCt0.3 Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. C0.15 D0.15 0.450.1 3.1250.15 0.4250.1 Position of the contact point Lock lever tab Position of the contact point Note 1 : The dimension in parentheses are for reference. 2 : Lead co-planarity including reinforced chucking metals shall be 0.1 max. 3 : To be delivered with tape and reel packages. See the packaging specifications for details. 4 : Note that preventive hole for sink mark or slit could be added for improvement. 5 : The quality remains good, even with the dark spots, which could occasionally occur on molded plastic. 6 : This product satisfies halogen free requirements defined as 900ppm maximum chlorine, 900ppm maximum bromine, and 1500ppm maximum total of chlorine and bromine. 7 Figure-1 Shows the state of opened lock cover. FPC can be pulled out by opening the lock lever by 45 degrees or more. Connector Dimensions Part No. FH62-13S-0.25SHW(**) FH62-15S-0.25SHW(**) FH62-17S-0.25SHW(**) FH62-19S-0.25SHW(**) FH62-21S-0.25SHW(**) FH62-23S-0.25SHW(**) FH62-25S-0.25SHW(**) FH62-27S-0.25SHW(**) FH62-31S-0.25SHW(**) FH62-35S-0.25SHW(**) FH62-39S-0.25SHW(**) FH62-41S-0.25SHW(**) FH62-51S-0.25SHW(**) FH62-55S-0.25SHW(**) FH62-61S-0.25SHW(**) HRS No. Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) 580-4300-0 ** Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Units : mm No. of contacts 13 15 17 19 21 23 25 27 31 35 39 41 51 55 61 A 6.46 6.96 7.46 7.96 8.46 8.96 9.46 9.96 10.96 11.96 12.96 13.46 15.96 16.96 18.46 B 2.5 3 3.5 4 4.5 5 5.5 6 7 8 9 9.5 12 13 14.5 C 3 3.5 4 4.5 5 5.5 6 6.5 7.5 8.5 9.5 10 12.5 13.5 15 D 6 6.5 7 7.5 8 8.5 9 9.5 10.5 11.5 12.5 13 15.5 16.5 18 E 4.43 4.93 5.43 5.93 6.43 6.93 7.43 7.93 8.93 9.93 10.93 11.43 13.93 14.93 16.43 Note 1 : Contact positions without HRS No. are currently under planning. Please contact hirose for detailed information about product variation. 3 FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector Recommended PCB Mounting Pattern B 0.80.02 (0.25) (n-1)/2x 0.3 0.02 0.5 0.02 X Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. 0.5 Contact No.1 (n+1)/2x 0.02 0.3 0.02 C 0.02 X X x4 0.4 0.02 F 2.80.02 Connector image 0.6 0.80.02 (0.175) 0.80.02 2.80.02 Contact No.2 0.02 X 0.670.01 Recommended stencil thicknesst=0.1 Land pattern image 0.5 (n+1)/2x 0.02 0.25 0.01 C 0.02 Y Y x4 0.35 0.01 F Y 0.630.01 0.6 (n-1)/2x 0.02 0.25 0.01 0.5 3.40.01 B (0.25) 3.40.01 (0.3) 0.770.01 Recommended Stencil Pattern 0.02 Y Note 8 : 'n' shows the number of contacts. Recommended Dimensions of PCB Mounting Pattern and Stencil Pattern Part No. FH62-13S-0.25SHW(**) FH62-15S-0.25SHW(**) FH62-17S-0.25SHW(**) FH62-19S-0.25SHW(**) FH62-21S-0.25SHW(**) FH62-23S-0.25SHW(**) FH62-25S-0.25SHW(**) FH62-27S-0.25SHW(**) FH62-31S-0.25SHW(**) FH62-35S-0.25SHW(**) FH62-39S-0.25SHW(**) FH62-41S-0.25SHW(**) FH62-51S-0.25SHW(**) FH62-55S-0.25SHW(**) FH62-61S-0.25SHW(**) HRS No. Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) 580-4300-0 ** Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) Under planning (Note 1) No. of contacts 13 15 17 19 21 23 25 27 31 35 39 41 51 55 61 Note 1 : Contact positions without HRS No. are currently under planning. Please contact hirose for detailed information about product variation. 4 B 2.5 3 3.5 4 4.5 5 5.5 6 7 8 9 9.5 12 13 14.5 C 3 3.5 4 4.5 5 5.5 6 6.5 7.5 8.5 9.5 10 12.5 13.5 15 Units : mm F 6.1 6.6 7.1 7.6 8.1 8.6 9.1 9.6 10.6 11.6 12.6 13.1 15.6 16.6 18.1 FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector Diagram of a recommended FPC dimension (when using plated lead part) (FPC contact thickness : t=0.300.03) 0.25 0.0 0.070.02 0.070.02 5 0.280.03 11 (n+1)/2x 0.02 X R0.20.05 0.30.03 (R 0. 0.450.05 1) 0.450.05 R0 .05 R0.20 0.280.03 0.150.02 0.150.02 Contact No.2 (n-1)/2x 0.02 X 10 G0.05 Note 9 Dimension R must be 0.5mm minimum. 10 Indicated tolerance is applicable to the exposed conductor. 11 Both end sides of contact pad on FPC cannot be used for signal transmission. Recommended FPC dimension (when not using plated lead part) 0.70.07 B 0.070.02 0.430.03 11 (n+1)/2x 0.02 Y (R R0.20.05 .1 5 R0 0. .15 05 0 .05 00.07 0.1 0.150.02 0.150.02 0.450.05 0.280.03 0.30.03 Contact No.1 ) 0.450.05 Contact No.2 9 R 3.20.3 Stiffener 0.25 Y 0.230.1 0.270.1 0.50.1 0.820.1 1.50.1 1.650.1 0.180.02 0.820.1 0.650.05 0.40.02 0.070.02 1.350.05 (FPC contact thickness : t=0.300.03) G0.05 C0.02 0.70.07 0.2850.02 0.150.02 0.070.07 R0 2.20.3 (exposed part of the conductor) 5 0.0 .2 R0 Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. X 9 R 3.20.3 Stiffener 2.20.3 .1 5 R0 0 (exposed part of the conductor) . 0 .1 1.350.05 5 5 0. 0.650.05 05 00.07 .2 0.70.07 B 0.270.1 0.50.1 0.820.1 1.50.1 1.650.1 G0.05 C0.02 0.70.07 0.2150.02 0.070.07 R0 Contact No.1 R0 .2 0 (n-1)/2x 0.02 Y .05 10 G0.05 Note 9 Dimension R must be 0.5mm minimum. 10 Indicated tolerance is applicable to the exposed conductor. 11 Both end sides of contact pad on FPC cannot be used for signal transmission. 5 FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. Recommended FPC Dimensions Units : mm Part No. HRS No. No. of contacts B C G FH62-13S-0.25SHW(**) Under planning (Note 1) 13 2.5 3 4.4 FH62-15S-0.25SHW(**) Under planning (Note 1) 15 3 3.5 4.9 FH62-17S-0.25SHW(**) Under planning (Note 1) 17 3.5 4 5.4 FH62-19S-0.25SHW(**) Under planning (Note 1) 19 4 4.5 5.9 FH62-21S-0.25SHW(**) Under planning (Note 1) 21 4.5 5 6.4 FH62-23S-0.25SHW(**) Under planning (Note 1) 23 5 5.5 6.9 FH62-25S-0.25SHW(**) Under planning (Note 1) 25 5.5 6 7.4 FH62-27S-0.25SHW(**) Under planning (Note 1) 27 6 6.5 7.9 FH62-31S-0.25SHW(**) Under planning (Note 1) 31 7 7.5 8.9 FH62-35S-0.25SHW(**) 580-4300-0 ** 35 8 8.5 9.9 FH62-39S-0.25SHW(**) Under planning (Note 1) 39 9 9.5 10.9 FH62-41S-0.25SHW(**) Under planning (Note 1) 41 9.5 10 11.4 FH62-51S-0.25SHW(**) Under planning (Note 1) 51 12 12.5 13.9 FH62-55S-0.25SHW(**) Under planning (Note 1) 55 13 13.5 14.9 FH62-61S-0.25SHW(**) Under planning (Note 1) 61 14.5 15 16.4 Note 1 : Contact positions without HRS No. are currently under planning. Please contact hirose for detailed information about product variation. FPC Construction (Recommended Specifications) MATERIAL NAME Covering film layer Cover adhesive Surface treatment MATERIAL Polyimide1mil 1m to 6m nickel underplated 0.2m gold plated Copper foil Cu1oz Base adhesive Heat-hardened adhesive Base film Polyimide 1mil Reinforcement Heat-hardened adhesive material adhesive Stiffener Polyimide7mil THICKNESS (m) 25 25 4 35 25 25 35 175 3. Caution 1.Material composition of FPC is a reference example. Please adjust the thickness of the FPC mating section to 0.30.03mm in reference to the material composition. 2.For the details of the material composition, please contact each FPC manufacturer. 6 FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector Packaging Specifications 40.1 (2) M0.1 1 0. 0 1.750.1 (1.35) (0.3) .5 CL 0.15 0 Direction of unreeling 0.1 0 1.5 1.7 Reel Dimensions CL Leader, Trailer Dimensions NReel inner width Direction of unreeling Direction of unreeling (O80) 400mm MINLeader (O380) O 13 Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. L0.1 K0.3 K M0.1 80.1 O1 1 0. 0 .5 O1 40.1 (2) +0.3 -0.1 80.1 (1.35) (0.3) Embossed Carrier Tape Dimensions (Tape width 32mm and over) 1.750.1 Embossed Carrier Tape Dimensions (Tape width up to 24mm) Top cover tape Embossed carrier tape 160mm MIN 100mm MIN Trailer, empty components empty components PReel outer width Units : mm Part No. HRS No. No. of contacts K L M N P FH62-13S-0.25SHW(**) Under planning (Note 1) 13 16 - 7.5 17.4 21.4 FH62-15S-0.25SHW(**) Under planning (Note 1) 15 FH62-17S-0.25SHW(**) Under planning (Note 1) 17 FH62-19S-0.25SHW(**) Under planning (Note 1) 19 FH62-21S-0.25SHW(**) Under planning (Note 1) 21 FH62-23S-0.25SHW(**) Under planning (Note 1) 23 FH62-25S-0.25SHW(**) Under planning (Note 1) 25 24 - 11.5 25.4 29.4 FH62-27S-0.25SHW(**) Under planning (Note 1) 27 FH62-31S-0.25SHW(**) Under planning (Note 1) 31 FH62-35S-0.25SHW(**) 580-4300-0 ** 35 FH62-39S-0.25SHW(**) Under planning (Note 1) 39 FH62-41S-0.25SHW(**) Under planning (Note 1) 41 FH62-51S-0.25SHW(**) Under planning (Note 1) 51 FH62-55S-0.25SHW(**) Under planning (Note 1) 55 32 28.4 14.2 33.4 37.4 FH62-61S-0.25SHW(**) Under planning (Note 1) 61 Note 1 : Contact positions without HRS No. are currently under planning. Please contact hirose for detailed information about product variation. 7 FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector Temperature Profile MAX 250 Applicable Conditions Temperature 245 Reflow method 220 Solder 200 : IR/Hot air Reflow environment : Room air : Paste type Sn/3.0Ag/0.5Cu (M705-GRN360-K2-V made by Senju 180 Metal Industry Co.) 150 Test PCB 150 : PCB material and size Glass epoxy 32.85x18.3x0.8mm Land size, per recommended on page 4. 100 Metal mask 20 to 40 sec. Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. 50 25 0 Per recommended on page 4. Peak temperature This temperature profile is based on the above conditions. 1205 sec. 60 to 90 sec. It may vastly depending on solder paste type, manufacturer, Preheating time Soldering time PCB size and mounting materials. Please use only after checking the mounting conditions. Start Timesec. 8 : Thickness and opening size FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector Connector operation and points to note [Operation method] As this connector is a small-sized, thin product, care needs to be taken when handling. Please check the following before use. 1. Initial condition The product is delivered with the lock lever closed, you do not need to operate it except for when removing the FPC. 2. How to insert FPC Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. Insert FPC with the conductor surface facing upwards, horizontal to the board surface. [Caution] During FPC insertion, do not twist the FPC to up and down, right and left or an angle. It may cause deformation of the contacts and contact failure. Lock lever (closed) FPC (horizontal) Lock lever (closed) FPC (horizontal) NG NG NG Lock lever (closed) Lock lever (open) FPC diagonal FPC (diagonal) 3. Check the inserted state of FPC When FPC is completely inserted, visually inspect the status. OK The outer shapes of FPC and the lock lever are parallel and inserted to the end. NG FPC is not inserted deep enough. NG FPC is inserted diagonally. 9 FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector Connector operation and points to note [Operation method] 4.How to remove FPC Push up the lock lever slowly, and release the lock. [Caution] The lock lever can't be opened over 180. After releasing the lock lever, do not touch the contact. Do not raise, pull, or twist the lock lever. Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. OK NG NG NG 180 Do not touch the contact. Rotational axis Excessive load is applied to the lock lever. Load is concentrated on the rotation axis, and leads to breakage. After releasing the lock lever, remove the FPC in the horizontal direction. After remove of the FPC, close the lock lever. [Caution] Do not pull out FPC while the lock lever is not opened to 45 or more. Ensure both ends of the lock lever are closed. OK Lock lever (open) 45 or more 45 FPC can be removed without letting the lock lever interfere with FPC. OK OK Close the both ends of the lock lever. NG FPC diagonal FPC diagonal 10 FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector Connector operation and points to note [Operation methods] 5. FPC routing after connection Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. qDepending on a FPC rounding, a load is applied to connector, and a contact failure may occur. To prevent a failure, take the following notes into a consideration during mechanism design. [Caution] * Make sure that FPC and stiffener do not contact chassis. * Avoid applying forces to FPC in vertical or horizontal directions. In addition, avoid pulling up and down on the FPC. * When fixing FPC after FPC cabling, avoid pulling FPC, and route the wire FPC with slack. In this regard, the stiffener is parallel to the PCB. * Do not mount other components touching to the FPC underneath the FPC stiffener. OK NG NG NG Stiffener Stiffener The state where a load is applied to FPC Mounting parts interfer with FPC The state where a load is applied to FPC [Cautions when Mounting PCB] SWarp of PCB Minimize warp of the PCB as much as possible. Lead co-planarity including reinforced metals is 0.1mm or less. Too much wrap of the PCB may result in a soldering failure. SFlexible board design Please make sure to put a stiffener on the backside of the flexible board. We recommend a glass epoxy material with the thickness of 0.3mm MIN. SLoad to Connector Do not add 1.0N or greater external force when unreel or pick and place the connector etc, or it may get broken. In addition, do not insert the FPC or operate the connector before mounting. SLoad to PCB * Splitting a large PCB into several pieces * Screwing the PCB Avoid the handling described above so that no force is exerted on the PCB during the assembly process. Otherwise, the connector may become defective. Connector FPC (for mounting connector) SInstructions on manual soldering Follow the instructions shown below when soldering the connector manually during work, etc. Do not perform any reflow or hand soldering operation while FPC is inserted in the connector. Do not apply extreme heat, or allow the soldering iron to touch anything other than the connector lead. This could cause the connector to be deformed or melted. Do not supply excessive solder (flux). If excessive solder (flux) is applied to the contact, the solder or flux could adhere on the contact point and cause contact failure. 11 Mar.1.2021Copyright2021HIROSEELECTRICCO.,LTD.AllRightsReserved. FH62 Series0.25mm pitch, 1.1mm high, Top Contact Single Action Lock, High FPC Retention Force FPC connector USA: HIROSE ELECTRIC (U.S.A.), INC. HEADQUARTERS CHICAGO OFFICE 2300 Warrenville Road, Suite 150, Downers Grove, IL 60515 Phone : +1-630-282-6700 http://www.hirose.com/us/ USA: HIROSE ELECTRIC (U.S.A.), INC. SAN JOSE OFFICE 2841 Junction Ave, Suite 200 San Jose, CA. 95134 Phone : +1-408-253-9640 Fax : +1-408-253-9641 http://www.hirose.com/us/ USA: HIROSE ELECTRIC (U.S.A.), INC. DETROIT OFFICE (AUTOMOTIVE) 17197 N. Laurel Park Drive, Suite 253, Livonia, MI 48152 Phone : +1-734-542-9963 Fax : +1-734-542-9964 http://www.hirose.com/us/ USA: HIROSE ELECTRIC (U.S.A.), INC. BOSTON OFFICE 300 Brickstone Square Suite 201, Andover, MA 01810 Phone : +1-978-662-5255 THE NETHERLANDS: HIROSE ELECTRIC EUROPE B.V. Hogehillweg #8 1101 CC Amsterdam Z-O Phone : +31-20-6557460 Fax : +31-20-6557469 http://www.hirose.com/eu/ GERMANY: HIROSE ELECTRIC EUROPE B.V. GERMAN BRANCH Schoenbergstr. 20, 73760 ostfildern Phone : +49-711-456002-1 Fax : +49-711-456002-299 http://www.hirose.com/eu/ GERMANY: HIROSE ELECTRIC EUROPE B.V. NUREMBERG OFFICE Neumeyerstrasse 22-26, 90411 Nurnberg Phone : +49-911 32 68 89 63 Fax : +49-911 32 68 89 69 http://www.hirose.com/eu/ GERMANY: HIROSE ELECTRIC EUROPE B.V. HANOVER OFFICE Bayernstr. 3, Haus C 30855 Langenhagen, Germany Phone : +49-511 97 82 61 30 Fax : +49-511 97 82 61 35 http://www.hirose.com/eu/ FRANCE: HIROSE ELECTRIC EUROPE B.V. PARIS OFFICE 130 Avenue Joseph Kessel, Bat E, 78960 Voisins le Bretonneux, France Phone : +33-1-85764886 Fax : +33-1-85764823 http://www.hirose.com/eu/ UNITED KINGDOM: HIROSE ELECTRIC EUROPE BV (UK BRANCH) 4 Newton Court, Kelvin Drive, Knowlhill, Milton Keynes, MK5 8NH Phone : +44-1908 202050 Fax : +44-1908 202058 http://www.hirose.com/eu/ CHINA: HIROSE ELECTRIC (SHANGHAI) CO., LTD. 18, Enterprise Center Tower 2, 209# Gong He Road, Jing'an District, Shanghai, CHINA 200070 Phone : +86-21-6391-3355 Fax : +86-21-6391-3335 http://www.hirose.com/cn/ CHINA: HIROSE ELECTRIC (SHANGHAI) CO.,LTD. BEIJING BRANCH A1001, Ocean International Center, Building 56# East 4th Ring Middle Road, ChaoYang District, Beijing, 100025 Phone : +86-10-5165-9332 Fax : +86-10-5908-1381 http://www.hirose.com/cn/ CHINA: HIROSE ELECTRIC TECHNOLOGIES (SHENZHEN) CO., LTD. Room 09-13, 19/F, Office Tower Shun Hing Square, Di Wang Commercial Centre, 5002 Shen Nan Dong Road, Shenzhen City, Guangdong Province, 518008 Phone : +86-755-8207-0851 Fax : +86-755-8207-0873 http://www.hirose.com/cn/ HONG KONG: HIROSE ELECTRIC HONGKONG TRADING CO., LTD. Room 1001, West Wing, Tsim Sha Tsui Centre, 66 Mody Road, Tsim Sha Tsui East, Kowloon, Hong Kong Phone : +852-2803-5338 Fax : +852-2591-6560 http://www.hirose.com/hk/ TAIWAN: HIROSE ELECTRIC TAIWAN CO., LTD. 103 8F, No.87, Zhengzhou Rd., Taipei Phone : +886-2-2555-7377 Fax : +886-2-2555-7350 http://www.hirose.com/tw/ KOREA: HIROSE KOREA CO.,LTD. 143, Gongdan 1-daero, Siheung-si, Gyeonggi-do, 15084, Korea Phone : +82-31-496-7000 Fax : +82-31-496-7100 http://www.hirose.co.kr/ SINGAPORE: INDIA: HIROSE ELECTRIC SINGAPORE PTE. LTD. DELHI LIAISON OFFICE HIROSE ELECTRIC SINGAPORE PTE. LTD. 03, Anson Road, #20-01, Springleaf Tower, Office NO.552, Regus-Green Boulevard, Level5, Tower C, Sec62, Plot B-9A, Block B, Noida, 201301, Uttar Pradesh, India Singapore 079909 Phone : +91-12-660-8018 Phone : +65-6324-6113 Fax : +91-120-4804949 Fax : +65-6324-6123 http://www.hirose.com/sg/ http://www.hirose.com/sg/ INDIA: HIROSE ELECTRIC SINGAPORE PTE. LTD. BANGALORE LIAISON OFFICE Unit No-403, 4th Floor, No-84, Barton Centre, Mahatma Gandhi (MG) Road, Bangalore 560 001, Karnataka, India Phone : +91-80-4120 1907 Fax : +91-80-4120 9908 http://www.hirose.com/sg/ MALAYSIA: THAILAND: PENANG REPRESENTATIVE OFFICE BANGKOK OFFICE (REPRESENTATIVE OFFICE) 73-3-1, Ideal@The One, Jalan Mahsuri, Bayan Unit 4703, 47th FL., 1 Empire Tower, South Sathorn Road, Yannawa, Sathorn, Bangkok 10120 Thailand Lepas Penang, 11950, Malaysia Phone : +66-2-686-1255 Phone : +604-648-5536 Fax : +66-2-686-3433 http://www.hirose.com/sg/ http://www.hirose.com/sg/ (R) 12 2-6-3,Nakagawa Chuoh,Tsuzuki-Ku,Yokohama-Shi 224-8540,JAPAN TEL: +81-45-620-3526 Fax: +81-45-591-3726 http://www.hirose.com http://www.hirose-connectors.com The characteristics and the specifications contained herein are for reference purpose. Please refer to the latest customer drawings prior to use. The contents of this catalog are current as of date of 09/2017. Contents are subject to change without notice for the purpose of improvements.