B320B - B360B 3.0A SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER Features Mechanical Data Guard Ring Die Construction for Transient Protection Ideally Suited for Automated Assembly Low Power Loss, High Efficiency Surge Overload Rating to 125A Peak For Use in Low Voltage, High Frequency Inverters, Free Case: SMB Case Material: Molded Plastic. "Green" Molding Compound. UL Flammability Classification Rating 94V-0 Wheeling, and Polarity Protection Application Moisture Sensitivity: Level 1 per J-STD-020 Terminals: Lead Free Plating (Matte Tin Finish). Solderable per MIL-STD-202, Method 208 Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2) Polarity: Cathode Band Halogen and Antimony Free. "Green" Device (Note 3) Weight: 0.093 grams (approximate) Qualified to AEC-Q101 Standards for High Reliability PPAP Capable (Note 4) Top View Bottom View Ordering Information (Note 5) Part Number* B3xxB-13-F B340BQ-13-F Compliance Standard Automotive Case SMB SMB Packaging 3000/Tape & Reel 3000/Tape & Reel * xx = Device type, e.g. B320B-13-F (SMB package). Notes: 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. 2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated's definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green" products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. 4. Automotive products are AEC-Q101 qualified and are PPAP capable. Automotive, AEC-Q101 and standard products are electrically and thermally the same, except where specified. For more information, please refer to http://www.diodes.com/quality/product_compliance_definitions/. 5. For packaging details, go to our website at http"//www.diodes.com/products/packages.html. Marking Information YWW Bxxx(x) B320B - B360B Document number: DS30924 Rev. 10 - 2 Bxxx(x) = Product type marking code, ex: B320B = Manufacturers' code marking YWW = Date code marking Y = Last digit of year (ex: 3 for 2013) WW = Week code (01 to 53) 1 of 5 www.diodes.com April 2013 (c) Diodes Incorporated B320B - B360B Maximum Ratings (@TA = +25C, unless otherwise specified.) Single phase, half wave, 60Hz, resistive or inductive load. For capacitance load, derate current by 20%. Characteristic Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage Average Rectified Output Current Symbol B320B B330B B340B/ B340BQ B350B B360B Unit VRRM VRWM VR 20 30 40 50 60 V @ TT =+100C Non-Repetitive Peak Forward Surge Current 8.3ms single half sine-wave superimposed on rated load IO 3.0 A IFSM 100 A Thermal Characteristics Symbol Value Unit Typical Thermal Resistance, Junction to Terminal (Note 6) Characteristic RJT 25 C/W Typical Thermal Resistance, Junction to Ambient (Note 6) RJA 95 C/W TJ -55 to +150 C TSTG -55 to +150 C Operating Temperature Range Storage Temperature Range Electrical Characteristics (@TA = +25C, unless otherwise specified.) Characteristic Symbol B320B,B330B,B340B,B340BQ B350B, B360B Forward Voltage Drop VF Leakage Current (Note 7) IR Total Capacitance CT Typ Max Unit -- -- -- -- 0.50 0.70 Test Condition V -- -- -- -- 0.5 20 mA @ Rated VR, TA = +25C @ Rated VR, TA = +100C -- -- 200 pF VR = 4V, f = 1MHz IF = 3.0A, TA = +25C 10 TA = 125 C TA = 75 C TA = 25 C 1.0 TA = -25 C 0.1 0.1 0.2 0.4 0.6 0.3 0.5 0.7 0.8 VF, INSTANTANEOUS FORWARD VOLTAGE (V) Figure 1 Typical Forward Characteristics - B320B thru B340B B320B - B360B Document number: DS30924 Rev. 10 - 2 IF, INSTANTANEOUS FORWARD CURRENT (A) 6. Thermal Resistance: Junction to terminal, unit mounted on glass epoxy substrate with 2x3mm copper pad. 7. Short duration pulse test used to minimize self-heating effect. IF, INSTANTANEOUS FORWARD CURRENT (A) Notes: Min 10 1.0 T A = 125C TA = 25C 0.1 0.01 0.8 1.0 0 0.2 0.4 0.6 VF, INSTANTANEOUS FORWARD VOLTAGE (V) Figure 2 Typical Forward Characteristics - B350B thru B360B 2 of 5 www.diodes.com April 2013 (c) Diodes Incorporated B320B - B360B 10,000 IR, INSTANTANEOUS REVERSE CURRENT (A) IR, INSTANTANEOUS REVERSE CURRENT (A) 10,000 TA = 125 C 1,000 100 TA = 75 C 10 TA = 25 C 1 0.1 TA = -25 C 0.01 10 30 50 20 40 60 VR, INSTANTANEOUS REVERSE VOLTAGE (V) Figure 3 Typical Reverse Characteristics, B320B thru B340B 0 1,000 100 TA = 70 C 10 1 0.1 0 3.0 IF(AV), AVERAGE FORWARD CURRENT (A) f = 1MHz CT, TOTAL CAPACITANCE (pF) TA = 25 C 40 60 30 50 20 70 10 VR, INSTANTANEOUS REVERSE VOLTAGE (V) Figure 4 Typical Reverse Characteristics, B350B thru B360B 1,000 100 10 1 0.1 T A = 125C 1 10 100 VR, DC REVERSE VOLTAGE (V) Figure 5 Total Capacitance vs. Reverse Voltage 2.5 2.0 1.5 1.0 0.5 0 25 50 75 100 125 150 TT, TERMINAL TEMPERATURE ( C) Figure 6 Forward Current Derating Curve IFSM, PEAK FORWARD SURGE CURRENT (A) 100 Single Half-Sine-Wave 80 TT = 100C 60 40 20 0 1 10 100 NUMBER OF CYCLES AT 60 Hz Figure 7 Max Non-Repetitive Peak Forward Surge Current B320B - B360B Document number: DS30924 Rev. 10 - 2 3 of 5 www.diodes.com April 2013 (c) Diodes Incorporated B320B - B360B Package Outline Dimensions B A SMB Dim Min Max A 3.30 3.94 B 4.06 4.57 C 1.96 2.21 D 0.15 0.31 E 5.00 5.59 G 0.05 0.20 H 0.76 1.52 J 2.00 2.50 All Dimensions in mm C D J H G E Suggested Pad Layout Dimensions Value (in mm) Z 6.8 G 1.8 X 2.3 Y 2.5 C 4.3 B320B - B360B Document number: DS30924 Rev. 10 - 2 4 of 5 www.diodes.com April 2013 (c) Diodes Incorporated B320B - B360B IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright (c) 2013, Diodes Incorporated www.diodes.com B320B - B360B Document number: DS30924 Rev. 10 - 2 5 of 5 www.diodes.com April 2013 (c) Diodes Incorporated