Electromagnetic Coupling RFID System V600 Non-contact Data Communications System * Superior environmental resistance. * Heat-resistant type available (150C max.). * High memory capacity of 8 Kbytes for Built-in-battery Data Carriers and 254 bytes for Battery-less Data Carriers. * Built-in-battery Data Carriers have a battery life detecting function. * Data of Battery-less Data Carriers can be overwritten 300,000 times at normal temperatures. * Thin, compact, and low-cost Data Carriers are available. * Transmission distance of 100 mm max. Ordering Information Data Carriers Item Built-in-battery DCs Specifications/Design/Memory capacity Rectangular compact 65 x 40 x 15 mm 8 Kbytes Model V600-D8KR12 Thin rectangular 86 x 54 x 10.3 mm V600-D8KR13 Intermediate-range rectangular 86 x 54 x 20 mm V600-D8KR04 Replaceable-battery DCs Compact 65 x 40 x 5 mm 2 Kbytes V600-D2KR16 Battery-less DCs 254 bytes V600-D23P71 2 Ultrathin card-type 86 x 54 x 1.5 mm Thin half-size card-type 50 x 34 x 1.5 mm V600-D23P72 Rectangular 34 x 34 x 3.5 mm V600-D23P66N Rectangular package with PFA 95 x 36.5 x 6.5 mm V600-D23P66SP Rectangular compact 32 x 24 x 6 mm V600-D23P61 Round super-compact 8 dia. x 5 mm V600-D23P53 Round compact 12 dia. x 6 mm V600-D23P54 Round super-compact 8 dia. x 5 mm V600-D23P55 Electromagnetic Coupling RFID System V600 R/W Heads Item Specifications/Design Dimensions: 100 x 100 x 30 mm Rectangular type Dimensions: 53 x 40 x 23 mm Dimensions: 22 dia. x 80 mm Cylinder type Dimensions: 22 dia. x 85 mm Separate-amplifier Amplifier type section Sensor section Model 0.5-m cable V600-H07 (0.5 m) 2-m cable V600-H07 (2 m) 5-m cable V600-H07 (5 m) 10-m cable V600-H07 (10 m) 0.5-m cable V600-H11 (0.5 m) 0.5-m cable V600-H11-R (0.5 m) 2-m cable V600-H11 (2 m) 5-m cable V600-H11 (5 m) 10-m cable V600-H11 (10 m) 0.5-m cable V600-H51 (0.5 m) 2-m cable V600-H51 (2 m) 5-m cable V600-H51 (5 m) 10-m cable V600-H51 (10 m) 0.5-m cable V600-H52 (0.5 m) 2-m cable V600-H52 (2 m) 5-m cable V600-H52 (5 m) 10-m cable V600-H52 (10 m) 73.8 x 22.6 x 36.5 mm, with 2-m cable V600-HA51 (2 m) 73.8 x 22.6 x 36.5 mm, with 5-m cable V600-HA51 (5 m) 73.8 x 22.6 x 36.5 mm, with 10-m cable V600-HA51 (10 m) 12 dia. x 35 mm deep, with 2-m cable V600-HS51 30.5 x 18 x 10 mm, with a 2-m cable V600-HS61 ID Controllers Item AC Power Supply DC Power Supply Specifications/Design 100 to 240 VAC, 50/60 Hz Two R/W Head connectors 200 x 100 x 100 mm 24 VDC R/W Head connectors 115 x 68 x 80 mm Model RS-232C host interface V600-CA1A-V2 RS-422 host interface V600-CA2A-V2 Parallel PNP host interface V600-CA8A-V2 Parallel NPN host interface V600-CA9A-V2 RS-232C host interface V600-CD1D-V3 24-VDC, 5-VDC 2-system input R/W Head connectors Board type V600-CM1D Handheld Controller A Battery Charger, Ni-Cd Battery Pack, Battery Case, and Carrying Belt are included. V600-CB-US-S AC Power Supply 100 to 240 VAC, 50/60 Hz Relay contact output type IDSC-C1DR-A 150 to 240 VAC, 50/60 Hz Transistor output type IDSC-C1DT-A RS-232C Host Interface; use V600-A20 power pack. V600-CH1D Handheld Reader/Writer Electromagnetic Coupling RFID System V600 3 Accessories (Order Separately) Item Specifications/Design Extension cable for R/W Heads Standard cable Non-water-resistant connectors Robotic cable Non-water-resistant connectors Holder Model 3-m cable V600-A45 5-m cable V600-A44 10-m cable V600-A40 20-m cable V600-A41 30-m cable V600-A42 3-m cable V600-A56 5-m cable V600-A55 10-m cable V600-A50 20-m cable V600-A51 30-m cable V600-A52 For the V600-D2KR16 *Mount with M3 flat countersunk head screws (at least two). V600-A81 For the V600-D23P71/D23P72 Ultrasonic deposition can be used on the plastic container. V600-A84 Attachment For the V600-D23P66N V600-A86 Lithium battery For the V600-D2KR16 Commercially available CR2016 battery (includes replacement battery cover seal, and cover) V600-A82 (5 in each set) Power pack For the RFID CH1D Reader/Writer V600-A20 Monitor Unit Special Unit for the V600-CA@A-@ Controller V600-P01 RS-232C Cables (Order Separately) Cable 2-m cable Compatible ID Controllers V600-CA1A-V2 5-m cable Connectors for ID Controllers (One Set per Unit) Model XW2Z-200P XW2Z-500P Connector Connector Plug Connector Hood 2-m cable 5-m cable V600-CD1D-V3 V600-CM1D XW2Z-200S XW2Z-500S Connector Plug Connector Hood Electromagnetic Coupling RFID System V600 Model V600-CA2A-V2 V600-CD1D-V3 V600-CM1D XM2A-0901 V600-CA1A-V2 XM2A-2501 Connector Hood Connector Plug 4 Compatible ID Controllers XM2S-0911 XM2S-2511 V600-CA8A-V2 V600-CA9A-V2 MR-50F (Honda Tsushin Kogyo) MR-50L (Honda Tsushin Kogyo) Specifications Battery-less Data Carriers Description Model Ultra-thin Card-type Ultra-thin Half-size Card-type Rectangular Compact Chemicalresistant Rectangular Compact Round Supercompact Round Compact Round Supercompact V600D23P71 V600D23P72 V600D23P66N V600D23P66SP V600D23P61 V600D23P53 V600D23P54 V600D23P55 Item Memory capacity 254 bytes Memory type EEPROM (non-volatile memory) Transmission distance Refer to "Transmission Distance Specifications for Battery-less DCs" on page 12. Data retention time (after writing data) 10 years Number of overwrites (per address) (Refer to separate item for ambient temperature) Up to 0C 800,000 times Up to 25C 400,000 times Up to 60C 300,000 times Up to 85C 100,000 times 10 years (-40 10 years to 110C) 1 year (-40 to 150C) 10 years (-40 to 110C) 1 year (-40 to 150C) Transmission error detection 16-bit CRC in both directions (CRC: Cyclic Redundancy Check) Ambient temperature -20 to 110C For data storage For reading/ -10 to 70C writing Storage temperature -20 to 110C Ambient humidity Operating: 35% to 95% Degree of protection -40 to 150C -40 to 110C -40 to 85C (See note.) -40 to 150C (See note.) -20 to 85C -25 to 85C -20 to 70C -25 to 70C -40 to 150C -40 to 110C -40 to 85C (See note.) -40 to 150C (See note.) IEC 60529: IP67 IEC 60529: IP68 IEC 60529: IP67 Vibration resistance (destruction) 10 to 2,000 Hz, 3.0-mm double amplitude, 300 m/s2 acceleration for 30 min each in 3 directions (90 min total) 10 to 2,000 10 to 2,000 Hz, 3.0-mm double amplitude, 300 m/s2 Hz, 1.5-mm acceleration for 30 min each in 3 directions (90 min double ampli- total) tude, 150 m/ s2 acceleration 10 times each in 3 directions (15 min) Shock resistance (destruction) 1,000 m/s2 3 times each in 3 directions (18 times total) 1,000 m/s2 3 times each in 3 500 m/s2 3 times each in directions (18 times total) 3 directions (18 times total) 500 m/s2 3 times each in 3 directions (18 times total) Weight Approx. 15 g Approx. 5 g Approx. 0.6 g IEC 60529: IP67 IEC 60529: IP67 Approx 6.5 g Approx. 19 g Approx. 5.8 g Approx. 0.4 Approx. g 1.0 g 10 to 2,000 Hz, 1.5-mm double amplitude, 150 m/s2 acceleration 10 times each in 3 directions (15 min) Note: The 150C heat resistance was confirmed by leaving the Unit at 150C for 1,000 continuous hours, and by a thermal shock test consisting of 1,000 -10C/150C cycles of 30 min each. No defect was found among the 22 test samples. Electromagnetic Coupling RFID System V600 5 Built-in-Battery Data Carriers Description Model Rectangular Compact Rectangular Thin V600-D8KR12 V600-D8KR13 Rectangular Intermediate Rectangular Compact with Range Replaceable Battery V600-D8KR04 V600-D2KR16 Item Memory capacity 8 Kbytes Memory type SRAM (volatile memory) 2 Kbytes Transmission distance Refer to "Transmission Distance Specifications for Built-in DCs" found in the Specifications section of this data sheet. Battery life (See note 1.) Refer to "Battery Life" found in the Specifications section of this data sheet. 2 years (at 25C) (See note 2.) Number of reads/writes Unlimited Unlimited (Does not affect battery life) Transmission error detection 16-bit CRC in both directions (CRC: Cyclic Redundancy Check) Ambient temperature For data storage -40 to 70C -15 to 70C For reading/ -25 to 70C writing 0 to 50C Storage temperature -40 to 70C -15 to 70C Ambient humidity 35% to 95% 35% to 85% Storage humidity 35% to 95% Degree of protection IEC 60529: IP67 Vibration resistance (destruction) 10 to 500 Hz, 1.0-mm single amplitude, 150 m/s2 acceleration for 11 min each in X, 10 to 150 Hz, 0.75-mm sinY, and Z directions gle amplitude, 100-m/s2 acceleration for 30 min each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s2 3 times each in X, Y, and Z directions (18 times total) 300 m/s2 3 times each in X, Y, and Z directions (18 times total) Weight Approx. 70 g Approx. 15 g IEC 60529: IP50 (dustproof) (See note 3.) Approx. 160 g Note: 1. A low battery detection function is built-in. 2. The battery life is applicable for batteries used at a temperature of 25C. For details on the relationship between temperature and battery life, refer to "Temperature and Battery Life," in this data sheet, found just before the "Precautions" section. The CR2016 is provided as the replacement battery (see "Accessories" in the Ordering Information of this data sheet). The Data Carrier is dustproof when the provided battery replacement cover seal is used. 6 Electromagnetic Coupling RFID System V600 Read/Write (R/W) Heads (with Built-in Amplifier) Model V600-H07 V600-H11/H11-R V600-H51 V600-H52 Item Oscillation frequency 530 kHz Ambient temperature -25 to 70C -10 to 60C Storage temperature -40 to 85C -25 to 75C Ambient humidity 35% to 95% Storage humidity 35% to 95% Insulation resistance 50 M (at 500 VDC) between cable terminals and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.) Degree of protection IEC 60529: IP67 Vibration resistance (destruction) 10 to 500 Hz, 1.0-mm single amplitude, 150 m/s2 acceleration with 3 sweeps of 11 min each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions (18 times total) Cable length (See note 1.) Standard lengths of 0.5 m, 2 m, 5 m, and 10 m. Wireless transmission error 16-bit CRC in both directions (CRC: Cyclic Redundancy Check) detection Indicators Power: green; transmission: orange Weight Approx. 1 kg (with 10-m cable) Approx. 650 g (with 10-m cable) Note: 1. Extension cables are also available. The maximum cable length is 30.5 m for the V600-H07 and 50.5 m for the V600-H11/H51/H52. 2. The connectors are not water-resistant. Electromagnetic Coupling RFID System V600 7 R/W Heads (with Separate Amplifier) Sensor section Model V600-HS51 Amplifier section V600-HS61 V600-HA51 Item Oscillation frequency 530 kHz Ambient temperature -10 to 60C --- Storage temperature -25 to 75C Ambient humidity 35% to 95% Insulation resistance 50 M (at 500 VDC) between cable terminals and case Dielectric strength 1,000 VAC 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.) Degree of protection IEC 60529: IP67 Vibration resistance (destruction) 10 to 2,000 Hz, 1.5-mm single amplitude, 300 m/s accel- Installed in panel eration with 2 sweeps of 15 min each in 3 directions IEC 60529: IP66 2 DIN Track installation 10 to 2,000 Hz, 1.5-mm single amplitude, 300-m/s2 acceleration with 2 sweeps of 11 min each in 3 directions 10 to 500 Hz, 1.0-mm single amplitude, 150-m/s2 acceleration with 3 sweeps of 11 min each in 3 directions Shock resistance (destruction) 1,000 m/s2 3 times each in 3 directions (18 times total) 500 m/s2 3 times each in 3 directions (18 times total) Cable length Sensor to amplifier 2 m (fixed) --- --- Standard lengths of 2 m, 5 m, and 10 m (See note 1.) Amplifier to controller Wireless transmission error 16-bit CRC in both directions (CRC: Cyclic Redundancy Check) detection Indicators --- Power: green; transmission: orange Weight Approx. 70 g (with 2-m cable) Approx. 650 g (with 10-m cable) Note: 1. Extension cables are also available. The maximum cable length is 50 m for the V600-HA51. Extension cables are not available for the V600-HS51/HS61. 2. The connectors are not water-resistant. 8 Electromagnetic Coupling RFID System V600 ID Controllers Series V600 Series (Electromagnetic RFID System) Model V600-CA1A-V2 V600-CA2A-V2 V600-CA8A-V2 V600-CA9A-V2 V600-CD1D-V3 V600-CM1D Item Parallel NPN output RS-232C RS-232C Possible number of R/W Heads 2 1 Power supply voltage 100 to 240 VAC, 50/60 Hz 24 VDC Acceptable power supply voltage 85 to 264 VAC 20.4 to 26.4 VDC 20.4 to 26.4 VDC 4.5 to 5.5 VDC Power consumption 35 VA max. 7.2 W max. Insulation resistance 50 M min. (at 500 VDC) between power terminals and case, between I/O terminals and case, or between the power supply terminals and I/O terminals Dielectric strength 1,500 VAC, 50/60 Hz for 1 min between the points listed above; Leakage current: 10 mA max. Noise immunity 1,500-V (p-p) pulses of 100-ns to 1-s pulse width with a 1-ns rise time Vibration resistance 10 to 150 Hz, 0.3-mm double amplitude for 32 min each in X, Y, and Z directions Destruction Malfunction Shock resistance RS-422A (Maximum of 16 Units can be connected) Parallel PNP output Host interface 24 VDC, 5 VDC 24 VDC: 7.2 W max. 5 VDC: 1.5 W max. 1,000 VAC, 50/60 Hz for 1 min between the points listed above; Leakage current: 10 mA max. 10 to 150 Hz, 0.2-mm double amplitude for 32 min each in X, Y, and Z directions Destruction: 200 m/s2 3 times each in X, Y, and Z directions (18 times total) Ambient temperature -10 to 55C Ambient humidity 35% to 85% (with no condensation) Operating conditions No corrosive gases 0 to 50C Storage temperature -25 to 65C Memory back-up A capacitor backs up the most recent error data and statistical error data for Memory backup is not available. Error up to 20 days (at 25C) after a power interruption. details, however, can be read from the personal computer when the power is turned ON. -15 to 70C Diagnostic functions Checks for CPU errors, memory errors, power interruptions, and transmission errors Ground Ground to 100 or less. Degree of protection IEC 60529: IP30 (panel mounted) Weight Approx. 890 g Approx. 930 g Approx. 960 g Approx 360 g Approx. 180 g Monitor Unit V600-P01 (for use with V600-CA@A Controllers) The Monitor Unit is a monitoring device that can be mounted to an ID Controller. It can be used to test communications between the R/W Head and Data Carrier when the RFID System is started up, check the data in Data Carriers, and read error information or statistical error information. The specifications conform to those of the ID Controller, except the operating temperature range is 0C to 40C. Electromagnetic Coupling RFID System V600 9 Handheld ID Controllers Model V600-CB-US-S Item Power supply Built-in nickel-cadmium batteries (6 VDC) or 9-V alkaline batteries (9 VDC) (See note.) Power consumption 700 mA max. Continuous operating time (See note.) 3 hrs min. when using the built-in nickel-cadmium batteries; 1.5 hrs min. when using the alkaline batteries Automatic power-saver The power is turned OFF automatically if a key input or response is not received in 10 min. Automatic command cancellation A command will be cancelled automatically if a response is not received from a Data Carrier within 2 min. Low battery indicator This display appears when the battery voltage falls below the minimum voltage required for operation. User memory 32 Kbytes (Data will be retained for at least 24 hrs after batteries are removed.) Vibration resistance Destruction: 10 to 150 Hz, 0.3-mm double amplitude for 32 min each in X, Y, and Z directions Shock resistance Destruction: 200 m/s2 3 times each in X, Y, and Z directions (18 times total) Ambient temperature 0 to 45C Ambient humidity 35% to 85% (with no condensation) Operating conditions No corrosive gases Storage temperature -25 to 60C (excluding the battery pack) Degree of protection IEC 60529: IP30 Weight 680 g max. (including the battery pack) Note: The continuous operating time is for new, fully charged nickel cadmium batteries or new alkaline batteries used at room temperature. Overseas specifications (with UL-listed Battery Charger) also available. V600-CB-US-S Configuration Item Description Model Handheld ID Controller Controller V600-CB-US Battery Charger Accessory V600-A14 Battery Case Accessory (for alkaline batteries) V600-A11 Ni-Cd Battery Pack Accessory (built-in to ID Controller) V600-A12 Carrying Belt Accessory V600-A13 Handheld V600-CH1D Wand Power supply 5 VDC from AC adapter Permissible power supply voltage 5 VDC 5% Current consumption 200 mA max. (See Note 1.) Insulation resistance 50 M min. (at 500 VDC) between cable terminals and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 min (1 mA max.) between cable terminals and case Noise immunity Power supply line: 1,200 Vp-p I/O line: 800 Vp-p Vibration resistance Destruction: 10 to 150 Hz, 0.3-mm single amplitude, with 4 sweeps of 8 min each in 3 directions Shock resistance Destruction: 294 m/S2 3 (approx. 20G) times each in 3 directions Ambient temperature Operating: -10 to 55C with no icing; storage: -25 to 65C with no icing Ambient humidity 35% to 85% (with no condensation) Operating conditions No corrosive gases Enclosure ratings IEC: IP63, JIS: IPX3 (waterproof) See note 2. Material Case: ABS resin; nameplate: PET resin Cable length 2.5 m Weight Approx. 180 g (including the connector and cable) Note: 1. This figure is for idling or stand-by. The rush current must be 250 mA max. 2. This does not include the connector section. The main unit is not resistant to chemicals or oils. 10 Electromagnetic Coupling RFID System V600 IDSC Series Series IDSC Series Model IDSC-C1DR-A IDSC-C1DT-A Item Host interface RS-232C Possible number of R/W Heads 1 Power supply voltage 100 to 240 VAC, 50/60 Hz Acceptable power supply voltage 85 to 264 VAC Power consumption 60 VA max. Insulation resistance 20 min. (at 500 VDC) between all Power Supply Unit AC external terminals and ground terminals Dielectric strength 2,300 VAC, 50/60 Hz for 1 min between Power Supply Unit AC external terminals and ground terminals Leakage current: 10 mA max. Noise immunity 1,500-V (p-p) pulses of 100-ns to 1-s pulse width with a 1-ns rise time Vibration resistance 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, 9.8 m/s2 acceleration for 80 min each in X, Y, and Z directions Shock resistance 150 m/s2 3 times each in X, Y, and Z directions Ambient temperature 0 to 55C Ambient humidity 10% to 90% (with no condensation) Operating conditions No corrosive gases Storage temperature -20 to 75C (excluding the battery pack) Memory back-up The battery life is 5 years regardless of whether an RTC is provided. The period that data is retained after a power interruption depends on the ambient temperature. Replace the battery within one week of the battery low indicator flashing. Diagnostic functions Checks for CPU errors, memory errors, power interruptions, and transmission errors Ground Ground to 100 or less. Construction Installed in panel Weight Approx. 1,500 g Note: Refer to the applicable ID Controller Operation Manual (Cat. No. W250) for details. Electromagnetic Coupling RFID System V600 11 Transmission Distance Specifications for Battery-less DCs Recommended combinations Data Carrier V600-D23P71 Installation R/W Head V600-H07 Stationary Read/Write distance Controller mode Irrelevant Moving V600-H11/-H11-R Stationary V600-H07 Stationary Read/Write distance Irrelevant Read/Write distance Irrelevant Moving V600-H11/-H11-R Stationary 10 to 70 mm (max. axial offset 10 mm) Condition for DC and R/W head installation These Data Carriers are for installation on non-metallic surfaces only. 30 to 60 mm (max. axial offset 10 mm) Moving V600-D23P72 Transmission distance 5 to 40 mm (max. axial offset 10 mm) R/W Head Data Carrier Iron Non-metallic (Resin, plastic, wood, etc.) 15 to 40 mm (max. axi- Data transmission will be impossial offset 10 mm) ble if the DC is installed directly on a metal surface. Refer to the V600 R/W Heads and EEPROM Data Carriers Operation Manual (Cat. No. Z128) for details. 10 to 50 mm (max. axial offset 10 mm) 30 to 40 mm (max. axial offset 10 mm) Read/Write distance Irrelevant Moving 5 to 30 mm (max. axial offset 10 mm) 15 to 30 mm (max. axial offset 10 mm) Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch or memory switch only with a Serial-interface Controller or ID Sensor Unit. 2. With Parallel-interface Controllers, the mode setting is always transmission distance priority. 3. The specifications take fluctuations in ambient temperature and slight differences between products into account. 12 Electromagnetic Coupling RFID System V600 Recommended combinations Data Carrier Installation R/W Head V600-D23P66N V600-H07 Stationary Moving V600-H11/-H11-R Stationary Moving V600D23P66SP V600-H07 Stationary Moving V600-H11/-H11-R Stationary Moving Read distance Controller mode Transmission distance Transmission 5 to 45 mm (max. distance priority axial offset 10 mm) Transmission time priority 5 to 35 mm (max. axial offset 10 mm) Write distance Irrelevant 5 to 35 mm (max. axial offset 10 mm) Read distance Transmission 25 to 40 mm (max. distance priority axial offset 10 mm) Transmission time priority 25 to 30 mm (max. axial offset 10 mm) Write distance Irrelevant 25 to 30 mm (max. axial offset 10 mm) Read distance Transmission 5 to 30 mm (max. distance priority axial offset 10 mm) Transmission time priority 5 to 25 mm (max. axial offset 10 mm) Write distance Irrelevant 5 to 25 mm (max. axial offset 10 mm) Read distance Transmission 15 to 25 mm (max. distance priority axial offset 10 mm) Transmission time priority 15 to 20 mm (max. axial offset 10 mm) Write distance Irrelevant 15 to 20 mm (max. axial offset 10 mm) Read distance Transmission 5 to 40 mm (max. distance priority axial offset 10 mm) Transmission time priority 5 to 30 mm (max. axial offset 10 mm) Write distance Irrelevant 5 to 30 mm (max. axial offset 10 mm) Read distance Transmission 20 to 40 mm (max. distance priority axial offset 10 mm) Transmission time priority 20 to 30 mm (max. axial offset 10 mm) Write distance Irrelevant 20 to 30 mm (max. axial offset 10 mm) Read distance Transmission 5 to 25 mm (max. distance priority axial offset 10 mm) Transmission time priority 5 to 20 mm (max. axial offset 10 mm) Write distance Irrelevant 5 to 20 mm (max. axial offset 10 mm) Read distance Transmission 10 to 25 mm (max. distance priority axial offset 10 mm) Write distance Condition for DC and R/W head installation Transmission time priority 10 to 20 mm (max. axial offset 10 mm) Irrelevant 10 to 20 mm (max. axial offset 10 mm) R/W Head Data Carrier Iron Non-metallic (Resin, plastic, wood, etc.) Data transmission will be impossible if the DC is installed directly on a metal surface. Refer to the V600 R/W Heads and EEPROM Data Carriers Operation Manual (Cat. No. Z128) for details. Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch or memory switch only with a Serial-interface Controller or ID Sensor Unit. 2. With Parallel-interface Controllers, the mode setting is always transmission distance priority. 3. The specifications take fluctuations in ambient temperature and slight differences between products into account. Electromagnetic Coupling RFID System V600 13 Recommended combinations Data Carrier V600-D23P61 Installation R/W Head V600-H11/-H11-R Stationary Moving V600-H51 Stationary Moving Read distance Controller mode Transmission distance Transmission 2 to 19 mm (max. distance priority axial offset 10 mm) Transmission time priority 2 to 16 mm (max. axial offset 10 mm) Write distance Irrelevant 2 to 16 mm (max. axial offset 10 mm) Read distance Transmission 12 to 19 mm (max. distance priority axial offset 10 mm) Transmission time priority 13 to 16 mm (max. axial offset 10 mm) Write distance Irrelevant 12 to 16 mm (max. axial offset 10 mm) Read distance Transmission 1 to 16 mm (max. distance priority axial offset 10 mm) Transmission time priority 1 to 14 mm (max. axial offset 10 mm) Write distance Irrelevant 1 to 14 mm (max. axial offset 10 mm) Read distance Transmission 7 to 16 mm (max. distance priority axial offset 10 mm) Write distance Transmission time priority 7 to 14 mm (max. axial offset 10 mm) Irrelevant 7 to 14 mm (max. axial offset 10 mm) Condition for DC and R/W head installation These Data Carriers can be installed on metallic surfaces. Data Carrier V600-H5 R/W Head Iron R/W Head Iron (SC, SS) Data Carrier Iron Iron (SC, SS) The listed transmission distances also apply for installation on nonmetallic surfaces. Refer to the V600 R/W Heads and EEPROM Data Carriers Operation Manual (Cat. No. Z128) for details. Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch or memory switch only with a Serial-interface Controller or ID Sensor Unit. 2. With Parallel-interface Controllers, the mode setting is always transmission distance priority. 3. The specifications take fluctuations in ambient temperature and slight differences between products into account. 14 Electromagnetic Coupling RFID System V600 Recommended combinations Data Carrier V600-D23P53 V600-HS51 (See note 4.) V600-HS61 (See note 4.) V600-H52 V600-D23P54 Installation R/W Head V600-HS51 (See note 4.) V600-HS61 (See note 4.) V600-H52 Stationary Stationary Stationary Stationary Stationary Stationary Read distance Controller mode Transmission distance 0.5 to 4.0 Transmission distance priority mm (max. axial offset 2 mm) 0.5 to 4.5 mm (max. axial offset 1 mm) Transmission time priority 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) Write distance Irrelevant 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) Read distance 0.5 to 4.0 Transmission distance priority mm (max. axial offset 2 mm) 0.5 to 4.5 mm (max. axial offset 1 mm) Transmission time priority 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) Write distance Irrelevant 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) Read distance 0.5 to 4.0 Transmission distance priority mm (max. axial offset 2 mm) 0.5 to 4.5 mm (max. axial offset 1 mm) Transmission time priority 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) Write distance Irrelevant 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) Read distance 0.5 to 6.0 Transmission distance priority mm (max. axial offset 2 mm) 0.5 to 6.5 mm (max. axial offset 1 mm) Transmission time priority 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) Write distance Irrelevant 0.5 to 5.0 mm (max. axial offset 2 mm) 0.5 to 5.5 mm (max. axial offset 1 mm) Read distance 0.5 to 6.5 Transmission distance priority mm (max. axial offset 2 mm) 0.5 to 7.0 mm (max. axial offset 1 mm) Transmission time priority 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) Write distance Irrelevant 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) Read distance 0.5 to 6.5 Transmission distance priority mm (max. axial offset 2 mm) 0.5 to 7.0 mm (max. axial offset 1 mm) Transmission time priority 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) Irrelevant 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) Write distance Condition for DC and R/W head installation These Data Carriers are for flush mounting in metallic bases only. Data Carrier V600-HS61 R/W Head Iron Iron (SC, SS) Data Carrier V600-HS51 R/W Head Iron Iron(SC, SS) Data Carrier V600-H52 R/W Head Iron Iron(SC, SS) The listed transmission distances also apply for installation on nonmetallic surfaces. Refer to the V600 R/W Heads and EEPROM Data Carriers Operation Manual (Cat. No. Z128) for details. Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch or memory switch only with a Serial-interface Controller or ID Sensor Unit. 2. With Parallel-interface Controllers, the mode setting is always transmission distance priority. 3. The specifications take fluctuations in ambient temperature and slight differences between products into account. 4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination. Electromagnetic Coupling RFID System V600 15 Recommended combinations Data Carrier V600-D23P55 Installation R/W Head V600-HS51 (See note 4.) Stationary Read distance Controller mode Transmission 0.5 to 6.5 mm (max. distance priority axial offset 2 mm) Transmission time priority Write distance Stationary Read distance Stationary Read distance Data Carrier V600-HS51 R/W Head Iron Non-metallic (Resin, plastic, wood, etc.) 0.5 to 6.0 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 2 mm) V600-HS61 R/W Head Data Carrier Transmission 0.5 to 9.0 mm (max. distance priority axial offset 2 mm) Transmission time priority Write distance 0.5 to 6.0 mm (max. axial offset 2 mm) Transmission 0.5 to 7.0 mm (max. distance priority axial offset 2 mm) Transmission time priority V600-H52 These Data Carriers are for flush mounting in non-metallic bases only. Transmission 0.5 to 7.0 mm (max. distance priority axial offset 2 mm) Transmission time priority Write distance 0.5 to 6.0 mm (max. axial offset 2 mm) Condition for DC and R/W head installation Transmission 0.5 to 6.5 mm (max. distance priority axial offset 2 mm) Transmission time priority V600-HS61 (See note 4.) Transmission distance 0.5 to 8.5 mm (max. axial offset 2 mm) Transmission 0.5 to 8.5 mm (max. distance priority axial offset 2 mm) Transmission time priority Iron Non-metallic (Resin, plastic, wood, etc.) 0.5 to 8.5 mm (max. axial offset 2 mm) Data Carrier V600-H52 R/W Head Iron Non-metallic (Resin, plastic, wood, etc.) The transmission distance decreases considerably when flush mounted in non-metallic bases. Refer to the V600 R/W Heads and EEPROM Data Carriers Operation Manual (Cat. No. Z128) for details. Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch or memory switch only with a Serial-interface Controller or ID Sensor Unit. 2. With Parallel-interface Controllers, the mode setting is always transmission distance priority. 3. The specifications take fluctuations in ambient temperature and slight differences between products into account. 4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination. 16 Electromagnetic Coupling RFID System V600 Transmission Distance Specifications for Built-in-Battery DCs Recommended combinations Data Carrier V600-D8KR12 Installation R/W Head V600-H07 Stationary Moving V600-H11 Stationary Moving Flushmounted in metal Controller mode Irrelevant V600-H07 Stationary Moving V600-H11 Stationary 10 to 50 mm (max. axial offset 10 mm) Surfacemounted on metal 10 to 60 mm (max. axial offset 10 mm) Flushmounted in metal 25 to 50 mm (max. axial offset 10 mm) Surfacemounted on metal 25 to 60 mm (max. axial offset 10 mm) Flushmounted in metal Irrelevant 5 to 40 mm (max. axial offset 10 mm) Condition for DC and R/W head installation R/W Head All metal Data Carrier Surface-mounted on metal All metal Data Carrier Flush-mounted in metal Surfacemounted on metal 5 to 45 mm (max. axial offset 10 mm) Flushmounted in metal 25 to 40 mm (max. The listed transmission distances axial offset 10 mm) also apply for installation on nonmetallic surfaces. Refer to the V600 R/W Heads and SRAM Data Carri25 to 45 mm (max. ers Operation Manual (Cat. No. axial offset 10 mm) Z127) for details. Surfacemounted on metal V600-D8KR13 Transmission distance Flushmounted in metal Irrelevant 10 to 30 mm (max. axial offset 10 mm) Surfacemounted on metal 10 to 35 mm (max. axial offset 10 mm) Flushmounted in metal 20 to 30 mm (max. axial offset 10 mm) Surfacemounted on metal 20 to 35 mm (max. axial offset 10 mm) Flushmounted in metal Irrelevant All metal 10 to 30 mm (max. axial offset 10 mm) Surfacemounted on metal Moving Flushmounted in metal 15 to 30 mm (max. axial offset 10 mm) Surfacemounted on metal Electromagnetic Coupling RFID System V600 17 Recommended combinations Data Carrier V600-D8KR04 (unsealed) Installation R/W Head V600-H07 Stationary Flushmounted in metal Controller mode Irrelevant V600-H11 Stationary Moving V600-D2KR16 V600-H11 Stationary Moving The listed transmission distances also apply for installation on nonmetallic surfaces. Refer to the V600 10 to 100 mm (max. R/W Heads and SRAM Data Carriaxial offset 10 mm) ers Operation Manual (Cat. No. Z127) for details. Flushmounted in metal See note1. Surfacemounted on metal 50 to 100 mm (max. axial offset 10 mm) Flushmounted in metal Irrelevant Refer to the V600 R/W Heads and SRAM Data Carriers Operation Manual (Cat. No. Z127) for details. See note1. Surfacemounted on metal 10 to 65 mm (max. axial offset 10 mm) Flushmounted in metal See note1. Surfacemounted on metal 30 to 65 mm (max. axial offset 10 mm) Flushmounted in metal Irrelevant 2 to 15 mm (max. axial offset 10 mm) (See note 2.) Surfacemounted on metal 2 to 15 mm (max. axial offset 10 mm) Flushmounted in metal 6 to 15 mm (max. axial offset 10 mm) See note 2.) Surfacemounted on metal 10 to 15 mm (max. axial offset 10 mm) Note: 1. When Data Carriers are flush-mounted in metal, the read/ write distance will depend on the distance (x) between the side of the DC and the metal surface. mm Flush-mounted Condition for DC and R/W head installation See note1. Surfacemounted on metal Moving Transmission distance 2. Use the following method for flush mounting into a metallic base. 10 mm min. 10 mm min. Flush-mounted mm All metal 20 mm max. All metal Combined with V600-H07 Combined with V600-H11 (Axial offset: 0 mm (Axial offset: 0 mm) 100 R/W Head 50 Data Carrier Transmission distance (mm) Transmission distance (mm) 100 80 60 40 R/W Head Data Carrier 20 0 18 40 60 80 (Above 100) Distance from metal surface ( ) (mm) 20 Electromagnetic Coupling RFID System V600 0 20 40 60 80 (Above 10 Distance from metal surface ( ) (mm Characteristic Data (Typical) Transmission Range Note: The values shown in the following graphs are in millimeters. Refer to the previous six pages for details on Data Carrier and R/W Head mounting conditions. Battery-less Compact DCs V600-D23P71 & V600-H07 V600-D23P71 & V600-H11 Y Y Y Y 80 100 80 60 X X 60 40 40 20 20 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 120 X V600-D23P72 & V600-H07 -100 -80 -60 -40 -20 0 20 40 60 100 X 80 V600-D23P72 & V600-H11 Y Y Y Y 60 100 80 X X 40 60 40 20 20 -120 -100 -80 -60 -40 -20 0 20 40 60 80 100 120 X V600-D23P66N & V600-H07 -80 -60 -40 -20 0 20 40 60 80 X V600-D23P66N & V600-H11 Y Y Y Y 60 80 X 60 X 40 40 20 20 -100 -80 -60 -40 -20 0 20 40 60 80 100 X V600-D23P66SP & V600-H07 -80 -60 -40 -20 0 20 40 60 80 X V600-D23P66SP & V600-H11 Y Y Y Y 60 80 60 X X 40 40 20 20 -100 -80 -60 -40 -20 0 20 40 60 80 100 X V600-D23P61 & V600-H11 -80 -60 -40 -20 0 20 40 60 80 X V600-D23P61 & V600-H51 Y Y Y Y 30 40 X X 30 20 20 10 10 -50 -40 -30 -20 -10 0 10 20 30 40 50 X Read range (in transmission distance priority mode) -40 -30 -20 -10 0 10 20 30 40 X Write range (in transmission distance or transmission time priority mode) Read range (in transmission time priority mode) Electromagnetic Coupling RFID System V600 19 V600-D23P53 & V600-HS51 +V600-HA51 V600-D23P53 & V600-HS61 +V600-HA51 Y V600-D23P53 & V600-H52 Y Y Y Y X X -5 0 5 -10 10 X V600-D23P54 & V600-HS51 +V600-HA51 5 -5 0 5 Y 5 5 5 10 Y 15 X -15 -5 0 5 10 15 X V600-D23P55 & V600-HS61 +V600-HA51 Y -15 -10 -5 0 X 5 5 5 15 X Y 15 10 10 15 X 10 5 10 Y Y 10 0 5 V600-D23P55 & V600-H52 15 X X Read range (in transmission distance priority mode) 20 -10 Y 15 -5 X 10 5 Y X 10 0 10 X 15 10 -5 5 Y 15 V600-D23P55 & V600-HS51 +V600-HA51 -10 0 Y X -15 -5 V600-D23P54 & V600-H52 Y 15 -10 -10 10 X V600-D23P54 & V600-HS61 +V600-HA51 Y -15 X 5 5 -10 Y 10 10 10 -15 -10 -5 0 5 10 15 X -15 -10 -5 0 Write range (in transmission distance or transmission time priority mode) Read range (in transmission time priority mode) Electromagnetic Coupling RFID System V600 5 10 15 X Built-in-Battery DCs V600-D8KR12 & V600-H07 V600-D8KR12 & V600-H11 Y Y Y Y 60 80 X X 60 40 40 20 20 -100 -80 -60 -40 -20 0 20 40 60 100 X 80 -80 V600-D8KR13 & V600-H07 -60 -40 -20 0 20 40 60 80 X V600-D8KR13 & V600-H11 Y Y Y Y 80 60 X X 60 40 40 20 20 -100 -80 -60 -40 -20 0 20 40 60 80 -80 100 X V600-D8KR04 & V600-H07 -60 -40 -20 0 20 40 60 80 X V600-D8KR04 & V600-H11 Y Y Y Y 80 120 X X 60 80 40 40 -160 -120 -80 20 -40 0 40 80 120 -100 -80 160 X -60 -40 -20 0 20 40 60 80 100 X Replaceable-Battery DCs V600-D2KR15 & V600-H11 Y Y 60 X 40 20 -80 -60 -40 -20 0 20 40 60 80 X Read/Write range (in transmission distance or transmission time priority mode) Electromagnetic Coupling RFID System V600 21 Transmission Time * The transmission time does not depend on the model of R/W Head or Data Carrier, although transmission times differ between Data Carriers with and without batteries. * The turn around time (TAT) is the total time required from the issuance of a command from the host device (for example, a host computer) until the reception of a response. * The lower-level communications time does not include the host communications; it is the time required for communications between the R/W Head and Data Carrier. The lower-level communications time is used in the equation for the DC speed. DC Speed = (Distance travelled in the transmission range)/ (Lower-level communications time) RDH1...............* Command RD001122...............* Lower-level communication time Response TAT (Turn Around Time) Transmission Time with Built-in-Battery Data Carriers (Reference) Transmission Time with Battery-less Data Carriers (Reference) Lower-level communication time (ms) Lower-level communication time (ms) 1,000 800 (Auto) Write 600 400 200 2,500 Transmission distance priority mode Transmission time priority mode 2,000 (Auto) Write 1,500 1,000 (Auto) Read 500 (Auto) Read 0 1 50 100 150 200 250 300 0 50 100 150 Number of bytes Calculation (Reference) t = 1.8 N + 48.4 WRITE t = 4.2 N + 86.5 N is the number of processing bytes. 250 300 Number of bytes Calculation (Reference) Lower-level communications time (ms) READ 200 R/W Lower-level communications time (ms) Distance priority READ mode WRITE t = 4.3 N + 64.6 Time priority mode READ t = 1.8 N + 79.0 WRITE t = 7.1 N + 180.4 t = 8.7 N + 167.1 N is the number of processing bytes. Lower-Level Communications Mode Setting (Distance/Time Priority) The lower-level communications mode setting is made with a DIP Switch or memory switch on the Serial-interface Controller (V600-CA1A-@/ -CA2A-@, V600-CD1D-V3, V600-CMID) or ID Sensor Unit. (Refer to the Controller's Operation Manual for more details on this setting.) With Parallel-interface Controllers (V600-CA8A-V2/CA9A-V2) the mode is fixed to transmission distance priority. 22 Electromagnetic Coupling RFID System V600 Battery Life The Data Carrier has a built-in lithium battery. The following graphs show the relationship between the number of bytes per transmission, the number of transmissions per day, and the battery life. V600-D8KR12 (Typical Example) V600-D8KR13 (Typical Example) V600-D8KR04 (Typical Example) 500 500 300 300 300 100 50 30 10 5 yrs 5 3 100 50 30 5 yrs 10 8 yrs 5 3 8 yrs 1 40 80 120 160 200 240 280 100 50 30 5 yrs 8 yrs 10 5 3 1 0 Transmissions/day (x100) 1,000 500 Transmissions/day (x100) 1,000 Transmissions/day (x100) 1,000 1 0 40 80 120 160 200 240 280 Bytes per transmission Bytes per transmission 0 40 80 120 160 200 240 280 Bytes per transmission Temperature and Battery Life V600-D2KR16 The battery life is two years at 25C regardless of the relationship between the number of bytes read/written and the number of transmissions. Examples Showing Relationship Between Battery Life and Temperature The following table shows the standard values. 2.5 Battery life (years) 2 1.5 1 Battery consumption rate in one year 20C 1% 30C 2% 40C 4% 50C 8% 60C 16% 70C 32% Note: If the battery is stored at 70C and is not installed, the battery life is calculated as follows: 2 (years) (1 - 0.32) = 1.36 years 0.5 0 Temperature 10 20 30 40 50 Ambient temperature (C) If the battery is stored at 25C after one year's storage, the battery life will be approximately 1 year and 4 months. (The battery life will be shortened if the battery is used at temperatures close to 0C or 50C.) The values in the above graph are based on the battery being installed (i.e., the insulation sheet is removed). If the battery is not installed, the values shown in the above table will apply. Precautions Correct Use Data Carrier Batteries Built-in-Battery Data Carriers Replaceable-Battery Data Carriers !Caution Never short-circuit the positive and negative terminals of the batteries, charge the batteries, disassemble them, deform them, or throw them into a fire. Doing so may cause the batteries to explode, combust, or leak liquid. !Caution Do not disassemble, deform by applying pressure, heat at temperatures exceeding 100C, or burn. Doing so may cause the built-in lithium batteries to combust or explode. Electromagnetic Coupling RFID System V600 23 Mutual Interference Mutual Interference Between R/W Heads When using more than one set of R/W Heads, mutual interference between the Heads can be avoided by mounting the Heads at the specified distance as shown below. V600-H07 V600-H11 * Facing RD/WT command: 650 mm min. Auto command: 900 mm min. * Facing RD/WT command: 200 mm min. Auto command: 200 min. 200 mm min. 650 mm min. (900 mm min.) * Side-by-side RD/WT command: 200 min. Auto command: 200 mm min. * Side-by-side RD/WT command: 550 mm min. Auto command: 1,200 mm min. 200 mm min. 550 mm min. (1,200 mm min.) V600-H51 V600-H52 V600-HS51 * Facing: 120 mm min. * Facing: 80 mm min. * Facing: 80 mm min. V600-HS51 V600-HS51 80 mm min. 120 mm min. * Side-by-side: 100 mm min. 100 mm min. 80 mm min. * Side-by-side: 80 mm min. * Side-by-side: 80 mm min. 80 mm min. 80 mm min. V600-HS51 V600-HS51 V600-HS61 * Facing: 80 mm min. V600 -HS61 * Side-by-side: 80 mm min. V600 -HS61 80 mm min. 80 mm min. Note: If the two R/W Heads are not transmitting simultaneously (i.e., independent read/write), mutual interference will not occur. Therefore, the restriction on the distance between the Heads will not be applicable. The commands will be received by the R/W Heads and transmission will oscillate between them. 24 Electromagnetic Coupling RFID System V600 Mutual Interference Between Proximity Sensors The V600-series Units use electromagnetic coupling (frequency: 530 kHz). When a V600 Unit is wired close to R/W Heads, Proximity Switches, and Sensors that have an oscillating frequency between 400 and 600 kHz, the Proximity Sensor may malfunction, so be sure to install the Units according to the distance restrictions specified in the following diagrams. Make sure to thoroughly test that the mounting positions and the fixed positions of the Sensors are correct before putting them into actual operation. V600-H07 V600-H11 * Vertical: 400 mm min. * Vertical: 100 mm min. Proximity Sensor Proximity Sensor 100 mm min. 400 mm min. 100 mm min. 400 mm min. V600-H11 Proximity Sensor V600-H07 Proximity Sensor * Facing: 100 mm min. 100 mm min. * Facing: 300 mm min. V600-H11 Proximity Sensor 300 mm min. V600-H07 Proximity Sensor V600-H51/H52 V600-HS51 V600-HS61 100 mm min. V600-HS61 Proximity Sensor Proximity Sensor Proximity Sensor 100 mm min. 100 mm min. Proximity Sensor V600-H51/52 Proximity Sensor Proximity Sensor V600-HS51 200 mm min. 100 mm min. 150 mm min. 150 mm min. 100 mm min. Proximity Sensor Proximity Sensor V600-HS61 Proximity Sensor Electromagnetic Coupling RFID System V600 25 Mutual Interference Between Data Carriers When more than one Data Carrier is used, mutual interference between the DCs can be avoided by making sure that they are mounted apart at the distances specified below. (Reading/writing) V600-D23P53 V600-D23P54 R/W Head: V600-H52, V500-HS51 + V600-HA51, V600-HS61 + V600-HA51 R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 + V600-HA51 40 mm min. 45 mm min. V600-D23P55 V600-D23P61 R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 + V600-HA51 R/W Head: V600-H11/-H51 50 mm min. 90 mm min. V600-D23P66N V600-D23P66SP R/W Head: V600-H11 R/W Head: V600-H11 140 mm min. 140 mm min. R/W Head: V600-H07 R/W Head: 600-H07 160 mm min. 160 mm min. V600-D23P72 R/W Head: V600-H11 R/W Head: V600-H51 R/W Head: V600-H07 150 mm min. 170 mm min. 210 mm min. 120 mm min. 140 mm min. 180 mm min. V600-D23P66SP R/W Head: V600-H07 290 mm min. 210 mm min. 26 Electromagnetic Coupling RFID System V600 V600-D8KR12 R/W Head: V600-H11 R/W Head: V600-H07 140 mm min. 160 mm min. 140 mm min. 160 mm min. V600-D8KR13 R/W Head: V600-H11 R/W Head: V600-H07 160 mm min. 180 mm min. 160 mm min. 160 mm min. V600-D8KR04 R/W Head: V600-H11 180 mm min. R/W Head: V600-H07 220 mm min. 180 mm min. V600-D2KR16 R/W Head: V600-H11 150 mm min. 90 mm min. Electromagnetic Coupling RFID System V600 27 Dimensions Note: All units are in millimeters unless otherwise indicated. Data Carriers Built-in-Battery DCs V600-D8KR12 V600-D8KR13 65 86 550.2 5 27 10 27 Two, 4.5-dia. mounting holes Two, 4.5-dia. mounting holes 10 10 10 54 440.2 40 300.2 15 Case: ABS resin Filler: Epoxy resin 8 760.2 5 Case: ABS resin Filler: Epoxy resin 10.3 5 V600-D8KR04 Replaceable-Battery DCs 86 31 5 V600-D2KR16 Four, 4.5-dia. mounting holes 5 760.2 4-R1.5 65 54 440.2 40 R0.5 20 Case: ABS resin Case: ABS resin Filler: Epoxy resin 10 5 Battery-less DCs V600-D23P53 V600-D23P54 V600-D23P55 V600-D23P61 36 8 12 - 00.2 dia. R0.2 0 dia. - 0.1 300.1 24 R0.3 R0.2 0 dia. 8- 0.1 24 2-R1.0 5 0 - 0.1 5 6 0 - 0.2 Two, 3.5-dia. mounting holes 0 - 0.1 6 2.2 Case: ABS resin Filler: Epoxy resin Case: ABS resin Filler: Epoxy resin Case: PPS resin Filler: Epoxy resin V600-D23P66N V600-D23P66SP Mounting Hole Dimensions 4-R4 250.2 Case: ABS resin Filler: Epoxy resin 4-R3 4-R6 34 Two, 5.5-dia. mounting holes 2-M3 Mounting Hole Dimensions 2-M5 36.5 34 34 250.2 32 800.2 250.2 Two, 3.5-dia. Two, 6-dia. 32 3.50.1 250.2 34 2.5 max. Case: PPS resin 28 Electromagnetic Coupling RFID System V600 Coating: PFA resin 6.5 1.3 800.2 95 V600-D23P71 V600-D23P72 4-R2 4-R2 50 86 34 54 Case: Glass epoxy resin Coating: Polyurethane resin 1.5 Case: Glass epoxy resin Coating: Polyurethane resin 1.5 R/W Heads V600-H07 Four, 4.5-dia. mounting holes 100 900.2 5 5 50 50 Power indicator (green) 25 43 100 900.2 14.7 dia. Transmission indicators (orange) Vinyl-insulated round cord (6-mm dia.) Bushing Connector 10 14 Case: ABS resin Filler: Epoxy resin Cable: PVC (oil-resistant) 10 30 20 11 V600-H11 4-R1 2-R5 Vinyl-insulated round cord (6-mm dia.) Two, 4.5-dia. mounting holes Bushing Connector Accessories: Two brackets for rear panel mounting 10 40 28 14.7 dia. 43 5 5 27 53 Power (green)/transmission (orange) indicators 6 5 13 20 Case: ABS resin Filler: Epoxy resin Cable: PVC (oil-resistant) 18 23 11 V600-H51 V600-HS51 (Sensor Section) 80 (72) (66) 62.5 7 2 lock washers 2 lock nuts M12X1 Vinyl-insulated round cord (4-mm dia.) Connector 43 9.6 dia. 14.7 dia. 19.8 dia. Connector Vinyl-insulated round cord (6-mm dia.) M22X1 2 lock washers 2 lock nuts Power (green)/transmission (orange) indicators 13.7 dia. 7 49.5 33 35 Case: Brass Transmission window: ABS resin Filler: Epoxy resin Cable: PVC (oil-resistant) Case: Brass Transmission window: ABS resin Filler: Epoxy resin Cable: PVC (oil-resistant) Electromagnetic Coupling RFID System V600 29 V600-H52 V600-HS61 (Sensor Section) 85 (77) (71) 67.5 30.5 18 12 4.5 8.5 120.1 49.5 43 18 Connector 14.7 dia. 12 dia. 13.7 dia. Detection surface Two, 3.5x5 mounting holes Connector Vinyl-insulated round cord (6-mm dia.) M22X1 2 lock washers 2 lock nuts 10 Power (green)/transmission (orange) indicators 6.5 Vinyl-insulated round cord (4-mm dia.) Case: ABS resin Filler: Epoxy resin Cable: PVC (oil-resistant) Case: Brass Transmission window: ABS resin Filler: Epoxy resin Cable: PVC (oil-resistant) V600-HA51 (Amplifier Section) Operating indicator (orange) Power indicator (green) 12.8 dia. 22.6 22 51.7 5.9 61.8 5 (10,000) 43 Connector 13.7 dia. 14.7 dia. 36.5 23.5 8 4 Two, 4.5-dia. mounting holes 30 13.2 51.30.2 35.6 6.1 Vinyl-insulated round cord Connector 6-mm dia (7/0.18-mm dia.), 8-conductor cable Electromagnetic Coupling RFID System V600 Case: ABS resin Filler: Epoxy resin Cable: PVC (oil-resistant) ID Controllers V600-P01 Monitor Unit (For use with V600-CA@A-@) V600-CA@A-@ (Multi-purpose) 35.3 100 900.3 80.6 120.6 22.6 9.3 1900.3 Four, 4.3-dia. mounting holes 200 100 V600-CB-US Handheld ID Controller V600-CD1D-V3 (Compact) 45.5 105 18 OPEN 53 68 17.5 5.5 50 81 92 270 80 Two, 4.5-dia. 115 V600-CM1D (Board-Mounted) 102 92 5 6 16.5 78 76 9 38 21.5 80 57.4 95 86.3 107 Four, 3.5-dia. R/W Head connector IDSC-C1D@-A (Stand-alone) 219 107 110 Electromagnetic Coupling RFID System V600 31 Accessories V600-CH1D Handheld Reader/Writer Operation indicator Activate switch Reset switch 45 23 3 25 5.5 11 65 49 2500 +500 106.5 44.9 24.99 10.523 32.2 10.5 dia. Connector 19020 Sensing surface Connector 34.5 Vinyl-insulated flat cable, 2 2 mm dia. (12/0.18 mm dia.), 2-core, standard length: 0.19 m Note: Requires EIAJ Class 2 plug (4.0 x 1.7 mm) from power source Holder Attachment V600-A81 for V600-D2KR16 Data Carriers 68 400.1 V600-A86 for V600-D23P66N Data Carriers 8-R0.5 Material: PPS resin 20 240.1 42 4-R5.5 250.2 Two, 4-dia. (Four, 3.5-dia.) (Four, 5.5-dia.) Case: ABS resin 9 37 34 15 16 250.2 3.5 2-R2.5 V600-A84 for V600-D23P71/-D23P72 Data Carriers 15 Use M3 countersunk screws in the two 3.2-dia. mounting holes or apply ultrasonic welding. 99.80.5 24.4 42.5 4 3.5 34 10 37 8.5 4-R3 5 Mounting Hole Dimensions 2.1 2-M3 67.80.5 63.6 2.1 2.1 95.6 250.2 250.2 2.1 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. 32 Electromagnetic Coupling RFID System V600 Terms and Conditions WARRANTY, LIMITATIONS OF LIABILITY of all possible uses of this product, nor is it intended to imply that the uses listed may be suitable for this product: WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. APPLICATION CONSIDERATIONS SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the product in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use which apply to the product. This information by itself is not sufficient for a complete determination of the suitability of the product in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. DISCLAIMERS PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors, or omissions. Complete terms and conditions for product purchase and use are on Omron's website at www.omron.com/oei - under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4 OMRON ELECTRONICS LLC OMRON CANADA, INC. OMRON ON-LINE One Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Toronto, Ontario M1B 5V8 847-843-7900 416-286-6465 Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca For US technical support or other inquiries: 800-556-6766 Cat. No. GC RFID 4 5/03 Specifications subject to change without notice Printed in USA Electromagnetic Coupling RFID System V600 33 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: XW2Z-500P XW2Z-200S XW2Z-500S