2Electromagnetic Coupling RFID System V600
Electromagnetic Coupling RFID System
V600
Non-contact Data Communications System
Superior environmental resistance.
Heat-resistant type available (150°C max.).
High memory capacity of 8 Kbytes for Built-in-battery Data
Carriers and 254 bytes for Battery-less Data Carriers.
Built-in-battery Data Carriers have a battery life detecting
function.
Data of Battery-less Data Carriers can be overwritten
300,000 times at normal temperatures.
Thin, compact, and low-cost Data Carriers are available.
Transmission distance of 100 mm max.
Ordering Information
Data Carriers
Item Specifications/Design/Memory capacity Model
Built-in-battery DCs Rectangular compact
65 × 40 × 15 mm
8 Kbytes V600-D8KR12
Thin rectangular
86 × 54 × 10.3 mm
V600-D8KR13
Intermediate-range rectangular
86 × 54 × 20 mm
V600-D8KR04
Replaceable-battery DCs Compact
65 × 40 × 5 mm
2 Kbytes V600-D2KR16
Battery-less DCs Ultrathin card-type
86 × 54 × 1.5 mm
254 bytes V600-D23P71
Thin half-size card-type
50 × 34 × 1.5 mm
V600-D23P72
Rectangular
34 × 34 × 3.5 mm
V600-D23P66N
Rectangular package with PFA
95 × 36.5 × 6.5 mm
V600-D23P66SP
Rectangular compact
32 × 24 × 6 mm
V600-D23P61
Round super-compact
8 dia. × 5 mm
V600-D23P53
Round compact
12 dia. × 6 mm
V600-D23P54
Round super-compact
8 dia. × 5 mm
V600-D23P55
Electromagnetic Coupling RFID System V600 3
R/W Heads
ID Controllers
Item Specifications/Design Model
Rectangular type Dimensions: 100 × 100 × 30 mm 0.5-m cable V600-H07 (0.5 m)
2-m cable V600-H07 (2 m)
5-m cable V600-H07 (5 m)
10-m cable V600-H07 (10 m)
Dimensions: 53 × 40 × 23 mm 0.5-m cable V600-H11 (0.5 m)
0.5-m cable V600-H11-R (0.5 m)
2-m cable V600-H11 (2 m)
5-m cable V600-H11 (5 m)
10-m cable V600-H11 (10 m)
Cylinder type Dimensions: 22 dia. × 80 mm 0.5-m cable V600-H51 (0.5 m)
2-m cable V600-H51 (2 m)
5-m cable V600-H51 (5 m)
10-m cable V600-H51 (10 m)
Dimensions: 22 dia. × 85 mm 0.5-m cable V600-H52 (0.5 m)
2-m cable V600-H52 (2 m)
5-m cable V600-H52 (5 m)
10-m cable V600-H52 (10 m)
Separate-amplifier
type
Amplifier
section
73.8 × 22.6 × 36.5 mm, with 2-m cable V600-HA51 (2 m)
73.8 × 22.6 × 36.5 mm, with 5-m cable V600-HA51 (5 m)
73.8 × 22.6 × 36.5 mm, with 10-m cable V600-HA51 (10 m)
Sensor
section
12 dia. × 35 mm deep, with 2-m cable V600-HS51
30.5 × 18 × 10 mm, with a 2-m cable V600-HS61
Item Specifications/Design Model
AC Power Supply 100 to 240 VAC, 50/60 Hz
Two R/W Head connectors
200 × 100 × 100 mm
RS-232C host interface V600-CA1A-V2
RS-422 host interface V600-CA2A-V2
Parallel PNP host interface V600-CA8A-V2
Parallel NPN host interface V600-CA9A-V2
DC Power Supply 24 VDC
R/W Head connectors
115 × 68 × 80 mm
RS-232C host interface V600-CD1D-V3
24-VDC, 5-VDC 2-system input
R/W Head connectors
Board type
V600-CM1D
Handheld Controller A Battery Charger, Ni-Cd Battery Pack, Battery Case, and
Carrying Belt are included.
V600-CB-US-S
AC Power Supply 100 to 240 VAC, 50/60 Hz
Relay contact output type
IDSC-C1DR-A
150 to 240 VAC, 50/60 Hz
Transistor output type
IDSC-C1DT-A
Handheld Reader/Writer RS-232C Host Interface; use V600-A20 power pack. V600-CH1D
4Electromagnetic Coupling RFID System V600
Accessories (Order Separately)
RS-232C Cables
(Order Separately)
Connectors for ID Controllers
(One Set per Unit)
Item Specifications/Design Model
Extension cable for
R/W Heads
Standard cable
Non-water-resistant connectors
3-m cable V600-A45
5-m cable V600-A44
10-m cable V600-A40
20-m cable V600-A41
30-m cable V600-A42
Robotic cable
Non-water-resistant connectors
3-m cable V600-A56
5-m cable V600-A55
10-m cable V600-A50
20-m cable V600-A51
30-m cable V600-A52
Holder For the V600-D2KR16
*Mount with M3 flat countersunk head screws (at least two).
V600-A81
For the V600-D23P71/D23P72
Ultrasonic deposition can be used on the plastic container.
V600-A84
Attachment For the V600-D23P66N V600-A86
Lithium battery For the V600-D2KR16
Commercially available CR2016 battery
(includes replacement battery cover seal, and cover)
V600-A82 (5 in
each set)
Power pack For the RFID CH1D Reader/Writer V600-A20
Monitor Unit Special Unit for the V600-CA@A-@ Controller V600-P01
Cable Compatible ID Controllers Model
2-m cable XW2Z-200P
5-m cable XW2Z-500P
2-m cable XW2Z-200S
5-m cable XW2Z-500S
V600-CA1A-V2
V600-CD1D-V3
V600-CM1D
Connector Compatible ID Controllers Model
Connector
Plug
XM2A-0901
Connector
Hood
XM2S-0911
Connector
Plug
XM2A-2501
Connector
Hood
XM2S-2511
Connector
Plug
MR-50F
(Honda Tsushin
Kogyo)
Connector
Hood
MR-50L
(Honda Tsushin
Kogyo)
V600-CA2A-V2
V600-CD1D-V3
V600-CM1D
V600-CA1A-V2
V600-CA8A-V2
V600-CA9A-V2
Electromagnetic Coupling RFID System V600 5
Specifications
Battery-less Data Carriers
Note: The 150°C heat resistance was confirmed by leaving the Unit at 150°C for 1,000 continuous hours, and by a thermal shock test consisting
of 1,000 -10°C/150°C cycles of 30 min each. No defect was found among the 22 test samples.
Description Ultra-thin
Card-type
Ultra-thin
Half-size
Card-type
Rectangular
Compact
Chemical-
resistant
Rectangular
Compact
Round
Super-
compact
Round
Compact
Round
Super-
compact
Item
Model V600-
D23P71
V600-
D23P72
V600-
D23P66N
V600-
D23P66SP
V600-
D23P61
V600-
D23P53
V600-
D23P54
V600-
D23P55
Memory capacity 254 bytes
Memory type EEPROM (non-volatile memory)
Transmission distance Refer to “Transmission Distance Specifications for Battery-less DCs” on page 12.
Data retention time
(after writing data)
10 years 10 years (40
to 110°C)
1 year (40 to
150°C)
10 years 10 years (40
to 110°C)
1 year (40 to
150°C)
Number of
overwrites
(per address)
(Refer to
separate item
for ambient
temperature)
Up to 0°C 800,000 times
Up to 25°C 400,000 times
Up to 60°C 300,000 times
Up to 85°C 100,000 times
Transmission error detection 16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Ambient
temperature
For data
storage
20 to 110°C−40 to 150°C
(See note.)
40 to 110°C40 to 85°C−40 to 150°C
(See note.)
For reading/
writing
10 to 70°C20 to 85°C20 to 70°C25 to 70°C25 to 85°C
Storage temperature 20 to 110°C−40 to 150°C
(See note.)
40 to 110°C40 to 85°C−40 to 150°C
(See note.)
Ambient humidity Operating: 35% to 95%
Degree of protection IEC 60529: IP67 IEC 60529:
IP68
IEC 60529:
IP67
IEC 60529: IP67 IEC 60529:
IP67
Vibration resistance
(destruction)
10 to 2,000 Hz, 3.0-mm
double amplitude, 300 m/s2
acceleration for 30 min
each in 3 directions (90 min
total)
10 to 2,000
Hz, 1.5-mm
double ampli-
tude, 150 m/
s2 accelera-
tion 10 times
each in 3 di-
rections (15
min)
10 to 2,000 Hz, 3.0-mm double amplitude, 300 m/s2
acceleration for 30 min each in 3 directions (90 min
total)
10 to 2,000
Hz, 1.5-mm
double
amplitude,
150 m/s2
acceleration
10 times
each in 3
directions
(15 min)
Shock resistance
(destruction) 1,000 m/s2 3 times each in 3
directions (18 times total)
500 m/s2 3
times each in
3 directions
(18 times to-
tal)
1,000 m/s2 3 times each in 3 directions (18 times total) 500 m/s2 3
times each in
3 directions
(18 times
total)
Weight Approx. 15 g Approx. 5 g Approx 6.5 g Approx. 19 g Approx. 5.8 g Approx. 0.4
g
Approx.
1.0 g
Approx. 0.6 g
6Electromagnetic Coupling RFID System V600
Built-in-Battery Data Carriers
Note: 1. A low battery detection function is built-in.
2. The battery life is applicable for batteries used at a temperature of 25°C. For details on the relationship between temperature and battery
life, refer to “Temperature and Battery Life,” in this data sheet, found just before the “Precautions” section. The CR2016 is provided as the
replacement battery (see “Accessories” in the Ordering Information of this data sheet). The Data Carrier is dustproof when the provided
battery replacement cover seal is used.
Description Rectangular Compact Rectangular Thin Rectangular Intermediate
Range
Rectangular Compact with
Replaceable Battery
Item
Model V600-D8KR12 V600-D8KR13 V600-D8KR04 V600-D2KR16
Memory capacity 8 Kbytes 2 Kbytes
Memory type SRAM (volatile memory)
Transmission distance Refer to “Transmission Distance Specifications for Built-in DCs” found in the Specifications section of this data
sheet.
Battery life
(See note 1.)
Refer to “Battery Life” found in the Specifications section of this data sheet. 2 years (at 25°C)
(See note 2.)
Number of reads/writes Unlimited Unlimited (Does not affect
battery life)
Transmission error detection 16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Ambient
temperature
For data
storage
40 to 70°C15 to 70°C
For reading/
writing
25 to 70°C0 to 50°C
Storage temperature 40 to 70°C15 to 70°C
Ambient humidity 35% to 95% 35% to 85%
Storage humidity 35% to 95%
Degree of protection IEC 60529: IP67 IEC 60529: IP50 (dustproof)
(See note 3.)
Vibration resistance
(destruction) 10 to 500 Hz, 1.0-mm single amplitude, 150 m/s2 acceleration for 11 min each in X,
Y, and Z directions
10 to 150 Hz, 0.75-mm sin-
gle amplitude, 100-m/s2 ac-
celeration for 30 min each in
X, Y, and Z directions
Shock resistance
(destruction) 1,000 m/s2 3 times each in X, Y, and Z directions (18 times total) 300 m/s2 3 times each in X,
Y, and Z directions (18 times
total)
Weight Approx. 70 g Approx. 160 g Approx. 15 g
Electromagnetic Coupling RFID System V600 7
Read/Write (R/W) Heads (with Built-in Amplifier)
Note: 1. Extension cables are also available. The maximum cable length is 30.5 m for the V600-H07 and 50.5 m for the V600-H11/H51/H52.
2. The connectors are not water-resistant.
Model V600-H07 V600-H11/H11-R V600-H51 V600-H52
Item
Oscillation frequency 530 kHz
Ambient temperature 25 to 70°C10 to 60°C
Storage temperature 40 to 85°C25 to 75°C
Ambient humidity 35% to 95%
Storage humidity 35% to 95%
Insulation resistance 50 M (at 500 VDC) between cable terminals and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.)
Degree of protection IEC 60529: IP67
Vibration resistance
(destruction)
10 to 500 Hz, 1.0-mm single amplitude, 150 m/s2 acceleration with 3 sweeps of 11 min each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions (18 times total)
Cable length (See note 1.) Standard lengths of 0.5 m, 2 m, 5 m, and 10 m.
Wireless transmission error
detection
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Indicators Power: green; transmission: orange
Weight Approx. 1 kg (with 10-m cable) Approx. 650 g (with 10-m cable)
8Electromagnetic Coupling RFID System V600
R/W Heads (with Separate Amplifier)
Note: 1. Extension cables are also available. The maximum cable length is 50 m for the V600-HA51. Extension cables are not available for the
V600-HS51/HS61.
2. The connectors are not water-resistant.
Sensor section Amplifier section
Item
Model V600-HS51 V600-HS61 V600-HA51
Oscillation frequency 530 kHz ---
Ambient temperature 10 to 60°C
Storage temperature 25 to 75°C
Ambient humidity 35% to 95%
Insulation resistance 50 M (at 500 VDC) between cable terminals and case
Dielectric strength 1,000 VAC 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.)
Degree of protection IEC 60529: IP67 IEC 60529: IP66
Vibration resistance
(destruction)
10 to 2,000 Hz, 1.5-mm single amplitude, 300 m/s2 accel-
eration with 2 sweeps of 15 min each in 3 directions
Installed in panel 10 to 2,000 Hz, 1.5-mm single am-
plitude, 300-m/s2 acceleration with 2
sweeps of 11 min each in 3 direc-
tions
DIN Track installa-
tion
10 to 500 Hz, 1.0-mm single ampli-
tude, 150-m/s2 acceleration with 3
sweeps of 11 min each in 3 direc-
tions
Shock resistance
(destruction)
1,000 m/s2 3 times each in 3 directions (18 times total) 500 m/s2 3 times each in 3 directions (18 times total)
Cable length Sensor to
amplifier
2 m (fixed) ---
Amplifier to
controller
--- Standard lengths of 2 m, 5 m, and 10 m (See note 1.)
Wireless transmission error
detection
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)
Indicators --- Power: green; transmission: orange
Weight Approx. 70 g (with 2-m cable) Approx. 650 g (with 10-m cable)
Electromagnetic Coupling RFID System V600 9
ID Controllers
Monitor Unit
V600-P01 (for use with V600-CA@A Controllers)
The Monitor Unit is a monitoring device that can be mounted to an ID
Controller. It can be used to test communications between the R/W
Head and Data Carrier when the RFID System is started up, check
the data in Data Carriers, and read error information or statistical
error information.
The specifications conform to those of the ID Controller, except the
operating temperature range is 0°C to 40°C.
Series V600 Series (Electromagnetic RFID System)
Model
Item
V600-CA1A-V2 V600-CA2A-V2 V600-CA8A-V2 V600-CA9A-V2 V600-CD1D-V3 V600-CM1D
Host interface RS-232C RS-422A
(Maximum of 16
Units can be
connected)
Parallel
PNP output
Parallel
NPN output
RS-232C
Possible number of R/W
Heads
2 1
Power supply voltage 100 to 240 VAC, 50/60 Hz 24 VDC 24 VDC, 5 VDC
Acceptable power supply
voltage
85 to 264 VAC 20.4 to 26.4 VDC 20.4 to 26.4 VDC
4.5 to 5.5 VDC
Power consumption 35 VA max. 7.2 W max. 24 VDC:
7.2 W max.
5 VDC:
1.5 W max.
Insulation resistance 50 M min. (at 500 VDC) between power terminals and case, between I/O terminals and case, or between the power
supply terminals and I/O terminals
Dielectric strength 1,500 VAC, 50/60 Hz for 1 min between the points listed above;
Leakage current: 10 mA max.
1,000 VAC, 50/60 Hz for 1 min
between the points listed above;
Leakage current: 10 mA max.
Noise immunity 1,500-V (p-p) pulses of 100-ns to 1-µs pulse width with a 1-ns rise time
Vibration
resistance
Destruction 10 to 150 Hz, 0.3-mm double amplitude for 32 min each in X, Y, and Z directions
Malfunction 10 to 150 Hz, 0.2-mm double amplitude for 32 min each in X, Y, and Z directions
Shock resistance Destruction: 200 m/s2 3 times each in X, Y, and Z directions (18 times total)
Ambient temperature 10 to 55°C0 to 50°C
Ambient humidity 35% to 85% (with no condensation)
Operating conditions No corrosive gases
Storage temperature 25 to 65°C15 to 70°C
Memory back-up A capacitor backs up the most recent error data and statistical error data for
up to 20 days (at 25°C) after a power interruption.
Memory backup is not available. Error
details, however, can be read from the
personal computer when the power is
turned ON.
Diagnostic functions Checks for CPU errors, memory errors, power interruptions, and transmission errors
Ground Ground to 100 or less.
Degree of protection IEC 60529: IP30 (panel mounted)
Weight Approx. 890 g Approx. 930 g Approx. 960 g Approx 360 g Approx. 180 g
10 Electromagnetic Coupling RFID System V600
Handheld ID Controllers
Note: The continuous operating time is for new, fully charged nickel cadmium batteries or new alkaline batteries used at room temperature. Over-
seas specifications (with UL-listed Battery Charger) also available.
V600-CB-US-S Configuration
Handheld V600-CH1D Wand
Note: 1. This figure is for idling or stand-by. The rush current must be 250 mA max.
2. This does not include the connector section. The main unit is not resistant to chemicals or oils.
Model V600-CB-US-S
Item
Power supply Built-in nickel-cadmium batteries (6 VDC) or 9-V alkaline batteries (9 VDC) (See note.)
Power consumption 700 mA max.
Continuous operating time
(See note.)
3 hrs min. when using the built-in nickel-cadmium batteries;
1.5 hrs min. when using the alkaline batteries
Automatic power-saver The power is turned OFF automatically if a key input or response is not received in 10 min.
Automatic command
cancellation
A command will be cancelled automatically if a response is not received from a Data Carrier within 2 min.
Low battery indicator This display appears when the battery voltage falls below the minimum voltage required for operation.
User memory 32 Kbytes (Data will be retained for at least 24 hrs after batteries are removed.)
Vibration resistance Destruction: 10 to 150 Hz, 0.3-mm double amplitude for 32 min each in X, Y, and Z directions
Shock resistance Destruction: 200 m/s2 3 times each in X, Y, and Z directions (18 times total)
Ambient temperature 0 to 45°C
Ambient humidity 35% to 85% (with no condensation)
Operating conditions No corrosive gases
Storage temperature 25 to 60°C (excluding the battery pack)
Degree of protection IEC 60529: IP30
Weight 680 g max. (including the battery pack)
Item Description Model
Handheld ID Controller Controller V600-CB-US
Battery Charger Accessory V600-A14
Battery Case Accessory (for alkaline batteries) V600-A11
Ni-Cd Battery Pack Accessory (built-in to ID Controller) V600-A12
Carrying Belt Accessory V600-A13
Power supply 5 VDC from AC adapter
Permissible power supply voltage 5 VDC ±5%
Current consumption 200 mA max. (See Note 1.)
Insulation resistance 50 Mmin. (at 500 VDC) between cable terminals and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min (1 mA max.) between cable terminals and case
Noise immunity Power supply line: 1,200 Vp-p
I/O line: 800 Vp-p
Vibration resistance Destruction: 10 to 150 Hz, 0.3-mm single amplitude, with 4 sweeps of 8 min each in 3 directions
Shock resistance Destruction: 294 m/S2 3 (approx. 20G) times each in 3 directions
Ambient temperature Operating: -10 to 55°C with no icing; storage: -25 to 65°C with no icing
Ambient humidity 35% to 85% (with no condensation)
Operating conditions No corrosive gases
Enclosure ratings IEC: IP63, JIS: IPX3 (waterproof) See note 2.
Material Case: ABS resin; nameplate: PET resin
Cable length 2.5 m
Weight Approx. 180 g (including the connector and cable)
Electromagnetic Coupling RFID System V600 11
IDSC Series
Note: Refer to the applicable ID Controller Operation Manual (Cat. No. W250) for details.
Series IDSC Series
Model
Item
IDSC-C1DR-A
IDSC-C1DT-A
Host interface RS-232C
Possible number of R/W Heads 1
Power supply voltage 100 to 240 VAC, 50/60 Hz
Acceptable power supply voltage 85 to 264 VAC
Power consumption 60 VA max.
Insulation resistance 20 min. (at 500 VDC) between all Power Supply Unit AC external terminals and ground terminals
Dielectric strength 2,300 VAC, 50/60 Hz for 1 min between Power Supply Unit AC external terminals and ground terminals
Leakage current: 10 mA max.
Noise immunity 1,500-V (p-p) pulses of 100-ns to 1-µs pulse width with a 1-ns rise time
Vibration resistance 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, 9.8 m/s2 acceleration for 80 min each in X, Y, and Z
directions
Shock resistance 150 m/s2 3 times each in X, Y, and Z directions
Ambient temperature 0 to 55°C
Ambient humidity 10% to 90% (with no condensation)
Operating conditions No corrosive gases
Storage temperature 20 to 75°C (excluding the battery pack)
Memory back-up The battery life is 5 years regardless of whether an RTC is provided.
The period that data is retained after a power interruption depends on the ambient temperature.
Replace the battery within one week of the battery low indicator flashing.
Diagnostic functions Checks for CPU errors, memory errors, power interruptions, and transmission errors
Ground Ground to 100 or less.
Construction Installed in panel
Weight Approx. 1,500 g
12 Electromagnetic Coupling RFID System V600
Transmission Distance Specifications for Battery-less DCs
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
Recommended combinations Installation Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Data Carrier R/W Head
V600-D23P71 V600-H07 Stationary Read/Write
distance
Irrelevant 10 to 70 mm (max.
axial offset ±10 mm)
These Data Carriers are for installa-
tion on non-metallic surfaces only.
Data transmission will be impossi-
ble if the DC is installed directly on
a metal surface. Refer to the V600
R/W Heads and EEPROM Data
Carriers Operation Manual (Cat.
No. Z128) for details.
Moving 30 to 60 mm (max.
axial offset ±10 mm)
V600-H11/-H11-R Stationary Read/Write
distance
Irrelevant 5 to 40 mm (max.
axial offset ±10 mm)
Moving 15 to 40 mm (max. axi-
al offset ±10 mm)
V600-D23P72 V600-H07 Stationary Read/Write
distance
Irrelevant 10 to 50 mm (max.
axial offset ±10 mm)
Moving 30 to 40 mm (max.
axial offset ±10 mm)
V600-H11/-H11-R Stationary Read/Write
distance
Irrelevant 5 to 30 mm (max.
axial offset ±10 mm)
Moving 15 to 30 mm (max.
axial offset ±10 mm)
Data Carrier
(Resin, plastic, wood, etc.)
Non-metallic
R/W Head
Iron
Electromagnetic Coupling RFID System V600 13
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
Recommended combinations Installation Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Data Carrier R/W Head
V600-D23P66N V600-H07 Stationary Read
distance
Transmission
distance priority
5 to 45 mm (max.
axial offset ±10 mm)
Data transmission will be impossi-
ble if the DC is installed directly on
a metal surface. Refer to the V600
R/W Heads and EEPROM Data
Carriers Operation Manual (Cat.
No. Z128) for details.
Transmission
time priority
5 to 35 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 5 to 35 mm (max.
axial offset ±10 mm)
Moving Read
distance
Transmission
distance priority
25 to 40 mm (max.
axial offset ±10 mm)
Transmission
time priority
25 to 30 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 25 to 30 mm (max.
axial offset ±10 mm)
V600-H11/-H11-R Stationary Read
distance
Transmission
distance priority
5 to 30 mm (max.
axial offset ±10 mm)
Transmission
time priority
5 to 25 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 5 to 25 mm (max.
axial offset ±10 mm)
Moving Read
distance
Transmission
distance priority
15 to 25 mm (max.
axial offset ±10 mm)
Transmission
time priority
15 to 20 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 15 to 20 mm (max.
axial offset ±10 mm)
V600-
D23P66SP
V600-H07 Stationary Read
distance
Transmission
distance priority
5 to 40 mm (max.
axial offset ±10 mm)
Transmission
time priority
5 to 30 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 5 to 30 mm (max.
axial offset ±10 mm)
Moving Read
distance
Transmission
distance priority
20 to 40 mm (max.
axial offset ±10 mm)
Transmission
time priority
20 to 30 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 20 to 30 mm (max.
axial offset ±10 mm)
V600-H11/-H11-R Stationary Read
distance
Transmission
distance priority
5 to 25 mm (max.
axial offset ±10 mm)
Transmission
time priority
5 to 20 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 5 to 20 mm (max.
axial offset ±10 mm)
Moving Read
distance
Transmission
distance priority
10 to 25 mm (max.
axial offset ±10 mm)
Transmission
time priority
10 to 20 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 10 to 20 mm (max.
axial offset ±10 mm)
(Resin, plastic, wood, etc.)
Non-metallic
Data CarrierR/W Head
Iron
14 Electromagnetic Coupling RFID System V600
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
Recommended combinations Installation Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Data Carrier R/W Head
V600-D23P61 V600-H11/-H11-R Stationary Read
distance
Transmission
distance priority
2 to 19 mm (max.
axial offset ±10 mm)
These Data Carriers can be in-
stalled on metallic surfaces.
The listed transmission distances
also apply for installation on non-
metallic surfaces. Refer to the V600
R/W Heads and EEPROM Data
Carriers Operation Manual (Cat.
No. Z128) for details.
Transmission
time priority
2 to 16 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 2 to 16 mm (max.
axial offset ±10 mm)
Moving Read
distance
Transmission
distance priority
12 to 19 mm (max.
axial offset ±10 mm)
Transmission
time priority
13 to 16 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 12 to 16 mm (max.
axial offset ±10 mm)
V600-H51 Stationary Read
distance
Transmission
distance priority
1 to 16 mm (max.
axial offset ±10 mm)
Transmission
time priority
1 to 14 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 1 to 14 mm (max.
axial offset ±10 mm)
Moving Read
distance
Transmission
distance priority
7 to 16 mm (max.
axial offset ±10 mm)
Transmission
time priority
7 to 14 mm (max.
axial offset ±10 mm)
Write
distance
Irrelevant 7 to 14 mm (max.
axial offset ±10 mm)
Data Carrier
Iron Iron (SC, SS)
Iron (SC, SS)
Data Carrier
R/W Head
Iron
V600-H5
R/W Head
Electromagnetic Coupling RFID System V600 15
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination.
Recommended combinations Installation Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Data Carrier R/W Head
V600-D23P53 V600-HS51
(See note 4.)
Stationary Read
distance
Transmission
distance priority
0.5 to 4.0
mm (max.
axial offset
±2 mm)
0.5 to 4.5
mm (max.
axial offset
±1 mm)
These Data Carriers are for flush
mounting in metallic bases only.
The listed transmission distances
also apply for installation on non-
metallic surfaces. Refer to the V600
R/W Heads and EEPROM Data
Carriers Operation Manual (Cat.
No. Z128) for details.
Transmission
time priority
0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
Write
distance
Irrelevant 0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
V600-HS61
(See note 4.)
Stationary Read
distance
Transmission
distance priority
0.5 to 4.0
mm (max.
axial offset
±2 mm)
0.5 to 4.5
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
Write
distance
Irrelevant 0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
V600-H52 Stationary Read
distance
Transmission
distance priority
0.5 to 4.0
mm (max.
axial offset
±2 mm)
0.5 to 4.5
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
Write
distance
Irrelevant 0.5 to 3.0
mm (max.
axial offset
±2 mm)
0.5 to 3.5
mm (max.
axial offset
±1 mm)
V600-D23P54 V600-HS51
(See note 4.)
Stationary Read
distance
Transmission
distance priority
0.5 to 6.0
mm (max.
axial offset
±2 mm)
0.5 to 6.5
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 5.5
mm (max.
axial offset
±2 mm)
0.5 to 6.0
mm (max.
axial offset
±1 mm)
Write
distance
Irrelevant 0.5 to 5.0
mm (max.
axial offset
±2 mm)
0.5 to 5.5
mm (max.
axial offset
±1 mm)
V600-HS61
(See note 4.)
Stationary Read
distance
Transmission
distance priority
0.5 to 6.5
mm (max.
axial offset
±2 mm)
0.5 to 7.0
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 5.5
mm (max.
axial offset
±2 mm)
0.5 to 6.0
mm (max.
axial offset
±1 mm)
Write
distance
Irrelevant 0.5 to 5.5
mm (max.
axial offset
±2 mm)
0.5 to 6.0
mm (max.
axial offset
±1 mm)
V600-H52 Stationary Read
distance
Transmission
distance priority
0.5 to 6.5
mm (max.
axial offset
±2 mm)
0.5 to 7.0
mm (max.
axial offset
±1 mm)
Transmission
time priority
0.5 to 5.5
mm (max.
axial offset
±2 mm)
0.5 to 6.0
mm (max.
axial offset
±1 mm)
Write
distance
Irrelevant 0.5 to 5.5
mm (max.
axial offset
±2 mm)
0.5 to 6.0
mm (max.
axial offset
±1 mm)
Iron
(SC, SS)
Data Carrier
V600-HS61
R/W Head
Iron
Iron(SC, SS)
Data Carrier
V600-HS51
R/W Head
Iron
Iron
(
SC, SS
)
Data Carrier
V600-H52
R/W Head
Iron
16 Electromagnetic Coupling RFID System V600
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch
or memory switch only with a Serial-interface Controller or ID Sensor Unit.
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.
4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination.
Recommended combinations Installation Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Data Carrier R/W Head
V600-D23P55 V600-HS51
(See note 4.)
Stationary Read
distance
Transmission
distance priority
0.5 to 6.5 mm (max.
axial offset ±2 mm)
These Data Carriers are for flush
mounting in non-metallic bases
only.
The transmission distance decreas-
es considerably when flush mount-
ed in non-metallic bases. Refer to
the V600 R/W Heads and EEPROM
Data Carriers Operation Manual
(Cat. No. Z128) for details.
Transmission
time priority
0.5 to 6.0 mm (max.
axial offset ±2 mm)
Write
distance
Transmission
distance priority
0.5 to 6.5 mm (max.
axial offset ±2 mm)
Transmission
time priority
0.5 to 6.0 mm (max.
axial offset ±2 mm)
V600-HS61
(See note 4.)
Stationary Read
distance
Transmission
distance priority
0.5 to 7.0 mm (max.
axial offset ±2 mm)
Transmission
time priority
0.5 to 6.0 mm (max.
axial offset ±2 mm)
Write
distance
Transmission
distance priority
0.5 to 7.0 mm (max.
axial offset ±2 mm)
Transmission
time priority
0.5 to 6.0 mm (max.
axial offset ±2 mm)
V600-H52 Stationary Read
distance
Transmission
distance priority
0.5 to 9.0 mm (max.
axial offset ±2 mm)
Transmission
time priority
0.5 to 8.5 mm (max.
axial offset ±2 mm)
Write
distance
Transmission
distance priority
0.5 to 8.5 mm (max.
axial offset ±2 mm)
Transmission
time priority
0.5 to 8.5 mm (max.
axial offset ±2 mm)
Data Carrier
V600-HS61
R/W Head
Iron
V600-HS51
R/W Head
Iron
V600-H52
R/W Head
Iron
(Resin, plastic, wood, etc.)
Non-metallic
Data Carrier
(Resin, plastic, wood, etc.)
Non-metallic
Data Carrier
(Resin, plastic, wood, etc.)
Non-metallic
Electromagnetic Coupling RFID System V600 17
Transmission Distance Specifications for Built-in-Battery DCs
Recommended combinations Installation Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Data Carrier R/W Head
V600-D8KR12 V600-H07 Stationary Flush-
mounted in
metal
Irrelevant 10 to 50 mm (max.
axial offset ±10 mm)
The listed transmission distances
also apply for installation on non-
metallic surfaces. Refer to the V600
R/W Heads and SRAM Data Carri-
ers Operation Manual (Cat. No.
Z127) for details.
Surface-
mounted on
metal
10 to 60 mm (max.
axial offset ±10 mm)
Moving Flush-
mounted in
metal
25 to 50 mm (max.
axial offset ±10 mm)
Surface-
mounted on
metal
25 to 60 mm (max.
axial offset ±10 mm)
V600-H11 Stationary Flush-
mounted in
metal
Irrelevant 5 to 40 mm (max.
axial offset ±10 mm)
Surface-
mounted on
metal
5 to 45 mm (max.
axial offset ±10 mm)
Moving Flush-
mounted in
metal
25 to 40 mm (max.
axial offset ±10 mm)
Surface-
mounted on
metal
25 to 45 mm (max.
axial offset ±10 mm)
V600-D8KR13 V600-H07 Stationary Flush-
mounted in
metal
Irrelevant 10 to 30 mm (max.
axial offset ±10 mm)
Surface-
mounted on
metal
10 to 35 mm (max.
axial offset ±10 mm)
Moving Flush-
mounted in
metal
20 to 30 mm (max.
axial offset ±10 mm)
Surface-
mounted on
metal
20 to 35 mm (max.
axial offset ±10 mm)
V600-H11 Stationary Flush-
mounted in
metal
Irrelevant 10 to 30 mm (max.
axial offset ±10 mm)
Surface-
mounted on
metal
Moving Flush-
mounted in
metal
15 to 30 mm (max.
axial offset ±10 mm)
Surface-
mounted on
metal
Data Carrie
r
Surface-mounted on metal
Data Carrier
Flush-mounted in metal
R/W Head
All metal
All metal
All metal
18 Electromagnetic Coupling RFID System V600
Note: 1. When Data Carriers are flush-mounted in metal, the read/
write distance will depend on the distance (x) between the
side of the DC and the metal surface.
2. Use the following method for flush mounting into a metallic
base.
Combined with V600-H07 Combined with V600-H11
V600-D8KR04
(unsealed)
V600-H07 Stationary Flush-
mounted in
metal
Irrelevant See note1. The listed transmission distances
also apply for installation on non-
metallic surfaces. Refer to the V600
R/W Heads and SRAM Data Carri-
ers Operation Manual (Cat. No.
Z127) for details.
Surface-
mounted on
metal
10 to 100 mm (max.
axial offset ±10 mm)
Moving Flush-
mounted in
metal
See note1.
Surface-
mounted on
metal
50 to 100 mm (max.
axial offset ±10 mm)
V600-H11 Stationary Flush-
mounted in
metal
Irrelevant See note1.
Surface-
mounted on
metal
10 to 65 mm (max.
axial offset ±10 mm)
Moving Flush-
mounted in
metal
See note1.
Surface-
mounted on
metal
30 to 65 mm (max.
axial offset ±10 mm)
V600-D2KR16 V600-H11 Stationary Flush-
mounted in
metal
Irrelevant 2 to 15 mm (max.
axial offset ±10 mm)
(See note 2.)
Surface-
mounted on
metal
2 to 15 mm (max.
axial offset ±10 mm)
Moving Flush-
mounted in
metal
6 to 15 mm (max.
axial offset ±10 mm)
See note 2.)
Surface-
mounted on
metal
10 to 15 mm (max.
axial offset ±10 mm)
Recommended combinations Installation Controller
mode
Transmission
distance
Condition for DC and R/W head
installation
Data Carrier R/W Head
Flush-mounted
mm mm
20 mm max.
All metal
Refer to the V600 R/W
Heads and SRAM Data
Carriers Operation Manual
(Cat. No. Z127) for details.
Flush-mounted
10 mm min. 10 mm min.
All metal
Transmission distance (mm)
100
50
0 20406080
(Axial offset: ±0 mm)
Distance from metal surface ( ) (mm)
R/W Head Data Carrier
(Above 100)
Transmission distance (mm)
80
60
40
20
100
0 20406080
(Axial offset: ±0 m
m
R/W Head Data Carrier
Distance from metal surface ( ) (m
m
(Above 10
Electromagnetic Coupling RFID System V600 19
Characteristic Data (Typical)
Transmission Range
Note: The values shown in the following graphs are in millimeters. Refer to the previous six pages for details on Data Carrier and R/W Head mount-
ing conditions.
Battery-less Compact DCs
V600-D23P71 & V600-H07
V600-D23P72 & V600-H07
V600-D23P66N & V600-H07
V600-D23P66SP & V600-H07
V600-D23P61 & V600-H11
V600-D23P71 & V600-H11
V600-D23P72 & V600-H11
V600-D23P66N & V600-H11
V600-D23P66SP & V600-H11
V600-D23P61 & V600-H51
020406080100120 20 40 60 80 100 120
20
40
60
80
100
Y
X
X
Y
0
20
40
60
80
100
120 20 40 60 80 100 120
20
40
60
80
100
Y
X
X
Y
020406080100 20 40 60 80 100
20
40
60
80
Y
X
X
Y
020406080100 20 40 60 80 100
20
40
60
80
Y
X
X
Y
01020304050 10 20 30 5040
10
20
30
40
Y
X
X
Y
0–20–40–60–80–100 20 40 60 80 100
20
40
60
80
Y
X
X
Y
0–20–40–60–80 20 40 60 80
20
40
60
Y
X
X
Y
020406080 20 40 60 80
20
40
60
Y
X
X
Y
020406080 20 40 60 80
20
40
60
X
Y
X
Y
010203040 10 20 30 40
10
20
30
Y
X
Y
X
Read range (in transmission distance priority mode) Write range (in transmission distance or transmission time priority mode)
Read ran
g
e
(
in transmission time
p
riorit
y
mode
)
20 Electromagnetic Coupling RFID System V600
0510 5
10
5
10
Y
Y
XX
X0510 5
10
5
10
Y
X
Y
X
0510 5
10
5
10
Y
X
Y
X
051015 5
15
10
5
1510
Y
X
Y
X051015 5
15
10
5
1510
YY
X
X051015 5
15
10
5
1510 X
YY
X
051015 5
10
15
5
10 15
Y
X
Y
X
051015 5
15
10
5
10 15
Y
X
Y
X
051015 5
15
10
5
10 15 X
YY
X
V600-D23P53 & V600-HS51
+V600-HA51
V600-D23P53 & V600-HS61
+V600-HA51 V600-D23P53 & V600-H52
V600-D23P54 & V600-HS51
+V600-HA51
V600-D23P54 & V600-HS61
+V600-HA51 V600-D23P54 & V600-H52
V600-D23P55 & V600-HS51
+V600-HA51
V600-D23P55 & V600-HS61
+V600-HA51 V600-D23P55 & V600-H52
Read range (in transmission distance priority mode) Write range (in transmission distance or transmission time priority mode)
Read ran
g
e
(
in transmission time
p
riorit
y
mode
)
Electromagnetic Coupling RFID System V600 21
Built-in-Battery DCs
V600-D8KR12 & V600-H07
V600-D8KR13 & V600-H07
V600-D8KR04 & V600-H07
V600-D8KR12 & V600-H11
V600-D8KR13 & V600-H11
V600-D8KR04 & V600-H11
Replaceable-Battery DCs
V600-D2KR15 & V600-H11
0–20–40–60–80–100 20 40 60 80 100
20
40
60
80
X
Y
X
Y
020406080100 20 40 60 80 100
20
40
60
80
X
Y
X
Y
04080120
160 40 80 120 160
40
80
120
X
Y
X
Y
020406080 20 40 60 80
20
40
60
X
Y
X
Y
020406080 20 40 60 80
20
40
60
X
Y
X
Y
020406080100 20 40 60 80 100
20
40
60
80
X
Y
X
Y
020406080 20 40 60 80
20
40
60
X
Y
X
Y
Read/Write range (in transmission distance or transmission time priority mode)
22 Electromagnetic Coupling RFID System V600
Transmission Time
The transmission time does not depend on the model of R/W Head
or Data Carrier, although transmission times differ between Data
Carriers with and without batteries.
The turn around time (TAT) is the total time required from the issu-
ance of a command from the host device (for example, a host com-
puter) until the reception of a response.
The lower-level communications time does not include the host
communications; it is the time required for communications
between the R/W Head and Data Carrier. The lower-level communi-
cations time is used in the equation for the DC speed.
DC Speed = (Distance travelled in the transmission range)/
(Lower-level communications time)
Transmission Time with Built-in-Battery Data
Carriers (Reference)
Calculation (Reference)
N is the number of processing bytes.
Transmission Time with Battery-less Data
Carriers (Reference)
Calculation (Reference)
N is the number of processing bytes.
Lower-Level Communications Mode Setting (Distance/Time Priority)
The lower-level communications mode setting is made with a DIP Switch or memory switch on the Serial-interface Controller (V600-CA1A-@/
-CA2A-@, V600-CD1D-V3, V600-CMID) or ID Sensor Unit. (Refer to the Controller’s Operation Manual for more details on this setting.)
With Parallel-interface Controllers (V600-CA8A-V2/CA9A-V2) the mode is fixed to transmission distance priority.
TAT (Turn Around Time)
Lower-level communication time
Command
Response
RD001122……………*
RDH1……………*
Lower-level communications time
(ms)
READ t = 1.8 N + 48.4
WRITE t = 4.2 N + 86.5
1,000
800
600
400
200
0
1 50 100 150 200 250 300
Number of bytes
Lower-level communication time (ms)
(Auto) Read
(Auto) Write
R/W Lower-level communications time
(ms)
Distance priority
mode
READ t = 4.3 N + 64.6
WRITE t = 8.7 N + 167.1
Time priority
mode
READ t = 1.8 N + 79.0
WRITE t = 7.1 N + 180.4
2,500
2,000
1,500
1,000
500
0 50 100 150 200 250 300
Number of bytes
Lower-level communication time (ms)
(Auto) Read
(Auto) Write
Transmission distance priority mode
Transmission time priority mode
Electromagnetic Coupling RFID System V600 23
Battery Life
The Data Carrier has a built-in lithium battery.
The following graphs show the relationship between the number of bytes per transmission, the number of transmissions per day, and the battery life.
Temperature and Battery Life
V600-D2KR16
The battery life is two years at 25°C regardless of the relationship between the number of bytes read/written and the number of transmissions.
Examples Showing Relationship Between Battery Life and Temperature
The following table shows the standard values.
Note: If the battery is stored at 70°C and is not installed, the battery
life is calculated as follows:
2 (years) (1 - 0.32) = 1.36 years
If the battery is stored at 25°C after one year’s storage, the bat-
tery life will be approximately 1 year and 4 months. (The battery
life will be shortened if the battery is used at temperatures close
to 0°C or 50°C.)
The values in the above graph are based on the battery being installed (i.e., the insulation sheet is removed). If the battery is not installed, the
values shown in the above table will apply.
Precautions
Correct Use
Data Carrier Batteries
Built-in-Battery Data Carriers
!Caution
Do not disassemble, deform by applying pressure, heat at temper-
atures exceeding 100°C, or burn. Doing so may cause the built-in
lithium batteries to combust or explode.
Replaceable-Battery Data Carriers
!Caution
Never short-circuit the positive and negative terminals of the bat-
teries, charge the batteries, disassemble them, deform them, or
throw them into a fire. Doing so may cause the batteries to ex-
plode, combust, or leak liquid.
1,000
500
300
100
50
30
10
5
3
10 40 80 120 160 200 240 280
1,000
500
300
100
50
30
10
5
3
10 40 80 120 160 200 240 280
1,000
500
300
100
50
30
10
5
3
10 40 80 120 160 200 240 280
Bytes per transmission
Transmissions/day (x100)
5 yrs
8 yrs
Bytes per transmission
5 yrs
8 yrs
Bytes per transmission
5 yrs
8 yrs
V600-D8KR12 (Typical Example) V600-D8KR13 (Typical Example) V600-D8KR04 (Typical Example)
Transmissions/day (x100)
Transmissions/day (x100)
2.5
2
1.5
1
0.5
01020304050
Ambient temperature (˚C)
Battery life (years)
Temperature Battery consumption rate in one year
20°C1%
30°C2%
40°C4%
50°C8%
60°C 16%
70°C 32%
24 Electromagnetic Coupling RFID System V600
Mutual Interference
Mutual Interference Between R/W Heads
When using more than one set of R/W Heads, mutual interference between the Heads can be avoided by mounting the Heads at the specified
distance as shown below.
V600-H07
Facing
RD/WT command: 650 mm min.
Auto command: 900 mm min.
Side-by-side
RD/WT command: 550 mm min.
Auto command: 1,200 mm min.
V600-H11
Facing
RD/WT command: 200 mm min.
Auto command: 200 min.
Side-by-side
RD/WT command: 200 min.
Auto command: 200 mm min.
V600-HS61
Facing: 80 mm min. Side-by-side: 80 mm min.
Note: If the two R/W Heads are not transmitting simultaneously (i.e., independent read/write), mutual interference will not occur. Therefore, the
restriction on the distance between the Heads will not be applicable.
The commands will be received by the R/W Heads and transmission will oscillate between them.
650 mm min.
(
900 mm min.
)
550 mm min.
(1,200 mm min.)
200 mm min.
200 mm min.
120 mm min. 80 mm min.
80 mm min.
V600-HS51V600-HS51
V600-H51
Facing: 120 mm min.
V600-H52
Facing: 80 mm min.
Side-by-side: 80 mm min.
V600-HS51
Facing: 80 mm min.
Side-by-side: 80 mm min.
100 mm min. 80 mm min.
80 mm min.
V600-HS51V600-HS51
Side-by-side: 100 mm min.
80 mm min.
V600
-HS61
V600
-HS61
80 mm min.
Electromagnetic Coupling RFID System V600 25
Mutual Interference Between Proximity Sensors
The V600-series Units use electromagnetic coupling (frequency: 530 kHz). When a V600 Unit is wired close to R/W Heads, Proximity Switches,
and Sensors that have an oscillating frequency between 400 and 600 kHz, the Proximity Sensor may malfunction, so be sure to install the Units
according to the distance restrictions specified in the following diagrams. Make sure to thoroughly test that the mounting positions and the fixed
positions of the Sensors are correct before putting them into actual operation.
V600-H07
Vertical: 400 mm min.
Facing: 300 mm min.
V600-H11
Vertical: 100 mm min.
Facing: 100 mm min.
400 mm min.
400 mm min.
Proximity Sensor
Proximity Sensor
V600-H07
300 mm min.
Proximity Sensor
V600-H0
7
100 mm min.
100 mm min.
Proximity Sensor
Proximity Sensor
V600-H11
100 mm min.
Proximity Sensor
V600-H11
100 mm min.
200 mm min.
150 mm min.
V600-H51/52
Proximity Sensor
Proximity Sensor
Proximity Sensor
100 mm min.
150 mm min.
V600-HS51
Proximity Sensor
Proximity Sensor
Proximity Sensor
100 mm min.
100 mm min.
100 mm min.
V600-HS61
V600-HS61
Proximity Sensor
Proximity Sensor
Proximity Sensor
V600-H51/H52 V600-HS51 V600-HS61
26 Electromagnetic Coupling RFID System V600
Mutual Interference Between Data Carriers
When more than one Data Carrier is used, mutual interference between the DCs can be avoided by making sure that they are mounted apart at
the distances specified below.
(Reading/writing)
V600-D23P53
R/W Head: V600-H52, V500-HS51 + V600-HA51, V600-HS61 +
V600-HA51
V600-D23P55
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +
V600-HA51
V600-D23P66N
R/W Head: V600-H11
R/W Head: V600-H07
V600-D23P54
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +
V600-HA51
V600-D23P61
R/W Head: V600-H11/-H51
V600-D23P66SP
R/W Head: V600-H11
R/W Head: 600-H07
V600-D23P72
V600-D23P66SP
R/W Head: V600-H07
40 mm min.
50 mm min.
140 mm min.
160 mm min.
45 mm min.
90 mm min.
140 mm min.
160 mm min.
150 mm min.
120 mm min.
170 mm min.
140 mm min.
210 mm min.
180 mm min.
R/W Head: V600-H51 R/W Head: V600-H11 R/W Head: V600-H07
290 mm min.
210 mm min.
Electromagnetic Coupling RFID System V600 27
V600-D8KR12
R/W Head: V600-H11 R/W Head: V600-H07
V600-D8KR13
R/W Head: V600-H11 R/W Head: V600-H07
V600-D8KR04
R/W Head: V600-H11 R/W Head: V600-H07
V600-D2KR16
R/W Head: V600-H11
140 mm min.
140 mm min.
160 mm min.
160 mm min.
160 mm min.
160 mm min.
180 mm min.
160 mm min.
180 mm min.
180 mm min.
220 mm min.
150 mm min.
90 mm min.
28 Electromagnetic Coupling RFID System V600
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Data Carriers
Built-in-Battery DCs
V600-D8KR12
V600-D8KR04
V600-D8KR13
Replaceable-Battery DCs
V600-D2KR16
Battery-less DCs
V600-D23P66N V600-D23P66SP
40 30±
0.2
10
65
55±
0.2
5
27 10
Two, 4.5-dia. mounting holes
15 8Case: ABS resin
Filler: Epoxy resin
54
20
44±
0.2
10
86
31
Four, 4.5-dia. mounting holes
55 76±
0.2
Case: ABS resin
Filler: Epoxy resin
86
27 Two, 4.5-dia. mounting holes
10
54 44±0.2
10.3 5
576±0.2
10
Case: ABS resin
Filler: Epoxy resin
65
4-R1.5
40
5
R0.5 Case: ABS resin
5 0
– 0.1 6 0
– 0.2
5 0
– 0.1
24
2.2
6
36
30±0.1
24
R0.2
8 0
– 0.1 dia.
2-R1.0
R0.3
12 0
– 0.2 dia. R0.2
8 0
– 0.1 dia.
Two, 3.5-dia. mounting holes
V600-D23P53 V600-D23P54 V600-D23P55 V600-D23P61
Case: ABS resin
Filler: Epoxy resin
Case: ABS resin
Filler: Epoxy resin
Case: PPS resin
Filler: Epoxy resin
Case: ABS resin
Filler: Epoxy resin
4-R4
32
34
25±
0.2
4-R3
32
34
25±
0.2
Two, 6-dia.
3.5±
0.1
Two, 3.5-dia.
25±
0.2
25±
0.2
2-M3
Case: PPS resin
Mounting Hole Dimensions
2-M5
4-R6
6.5
2.5 max.
34
36.5
34
80±
0.2
95
1.3
80±
0.2
Mounting Hole Dimensions
Coating: PFA resin
Two, 5.5-dia.
mounting holes
Electromagnetic Coupling RFID System V600 29
V600-D23P71 V600-D23P72
R/W Heads
V600-H07
V600-H11
V600-H51 V600-HS51 (Sensor Section)
54
1.5
86
4-R2
Case: Glass epoxy resin
Coating: Polyurethane resin
50
4-R2
34
1.5
Case: Glass epoxy resin
Coating: Polyurethane resin
50
55
100
90±
0.2
Four, 4.5-dia.
mounting holes
100
90±
0.2
50
14
Power indicator
(green)
Transmission
indicators
(orange)
10
10
25 43
Connector
14.7 dia.
Bushing Vinyl-insulated
round cord
(6-mm dia.)
30
20 11
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
23
11
5
Power (green)/transmission
(orange) indicators
5
4-R1
40 28
2-R5 Two, 4.5-dia. mounting holes
10
Bushing
14.7 dia.
43
Vinyl-insulated round cord (6-mm dia.)
Connector
27
53
6
20 18
135
Accessories: Two brackets
for rear panel mounting
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
19.8 dia.
7
62.5
M22X1
2 lock washers 2 lock nuts Power (green)/transmission (orange) indicators
Vinyl-insulated round cord (6-mm dia.)
Connector
(66)
(72)
80
43
14.7 dia.
Case: Brass
Transmission window: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
33
35
49.5
7
M12X1
2 lock washers
2 lock nuts
Vinyl-insulated round cord
(4-mm dia.)
Connector
9.6 dia. 13.7 dia.
Case: Brass
Transmission window: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
30 Electromagnetic Coupling RFID System V600
V600-H52 V600-HS61 (Sensor Section)
V600-HA51 (Amplifier Section)
12 dia.
12
67.5
M22X1
2 lock washers 2 lock nuts Power (green)/transmission (orange) indicators
Vinyl-insulated round cord (6-mm dia.)
Connector
(71)
(77)
85
43
14.7 dia.
Case: Brass
Transmission window: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
30.5
18 4.5
8.5 12±
0.1
49.5
18
10
13.7 dia.
Detection surface
Connector
Vinyl-insulated round cord
(4-mm dia.)
6.5
Two, 3.5x5
mounting holes
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
22.6
36.5
23.5
8
6.1
Vinyl-insulated round cord
6-mm dia (7/0.18-mm dia.),
8-conductor cable
Connector
14.7 dia.
35.6
13.2
Two, 4.5-dia. mounting holes
51.3±0.2
4
13.7 dia.
22
51.7
61.85.9 5
12.8 dia.
(10,000)
43
Power indicator (green)
Connector
Operating indicator (orange)
Case: ABS resin
Filler: Epoxy resin
Cable: PVC (oil-resistant)
Electromagnetic Coupling RFID System V600 31
ID Controllers
IDSC-C1D@-A (Stand-alone)
9.3
35.3
100
200
190±0.3
90±0.3
100 80.6
120.6
22.6
OPEN
5.5
53
81
92
115
80
50
17.5
18
68
76
78
92
102
21.5
9
6
5
57.4
86.3
95
107
16.5
105
45.5
270
80
38
Four, 4.3-dia.
mounting holes
V600-CA@A-@ (Multi-purpose)
V600-CD1D-V3 (Compact)
Two, 4.5-dia.
Four, 3.5-dia.
R/W Head connector
V600-CM1D (Board-Mounted)
V600-P01 Monitor Unit
(For use with V600-CA@A-@)
V600-CB-US Handheld
ID Controller
110
219 107
32 Electromagnetic Coupling RFID System V600
Accessories
V600-CH1D Handheld Reader/Writer
Holder
V600-A81 for V600-D2KR16 Data Carriers
V600-A84 for V600-D23P71/-D23P72 Data Carriers
Attachment
V600-A86 for V600-D23P66N Data Carriers
10.5 dia.
Connector 34.5
190±20
32.2
24.99
44.9
2500
+50
0
106.5
10.523
Sensing surface Connector
Note: Requires EIAJ Class 2 plug (4.0 x 1.7 mm) from power source
Vinyl-insulated flat cable, 2 2 mm dia. (12/0.18 mm dia.),
2-core, standard length: 0.19 m
4
65
2
3
3
4
5
.
5
2
5
Operation indicator
Operation
indicator
A
c
tiv
a
t
e
s
wit
ch
R
ese
t
s
wit
ch
11
9
3.5
2-R2.5
20 42
24±
0.1
68
40±
0.1
(Four, 3.5-dia.)
(Four, 5.5-dia.)
8-R0.5
Case: ABS resin
2.195.62.1
4-R3
24.4
99.8±
0.5
42.5
2.1
63.6
2.1
8.5
5
67.8±
0.5
Use M3 countersunk screws in the two 3.2-dia.
mounting holes or apply ultrasonic welding.
25±
0.2
25±
0.2
25±
0.2
25±
0.2
15
34
37
1534
37 16
4
10
3.5
Two, 4-dia.
4-R5.5
2-M3
Material: PPS resin
Mounting Hole Dimensions
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Electromagnetic Coupling RFID System V600 33
Terms and Conditions
WARRANTY, LIMITATIONS OF
LIABILITY
WARRANTY OMRON’s exclusive warranty is that the products are
free from defects in materials and workmanship for a period of one
year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE
OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES
THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED
USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS
OR IMPLIED.
LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSI-
BLE FOR SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CON-
NECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED ON CONTRACT, WARRANTY, NEGLIGENCE OR STRICT
LIABILITY.
In no event shall responsibility of OMRON for any act exceed the indi-
vidual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WAR-
RANTY, REPAIR OR OTHER CLAIMS REGARDING THE PROD-
UCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED
AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION,
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR
REPAIR.
APPLICATION CONSIDERATIONS
SUITABILITY FOR USE OMRON shall not be responsible for confor-
mity with any standards, codes or regulations which apply to the
combination of the product in the customer's application or use of the
product.
At the customer's request, OMRON will provide applicable third party
certification documents identifying ratings and limitations of use
which apply to the product. This information by itself is not sufficient
for a complete determination of the suitability of the product in combi-
nation with the end product, machine, system, or other application or
use.
The following are some examples of applications for which particular
attention must be given. This is not intended to be an exhaustive list
of all possible uses of this product, nor is it intended to imply that the
uses listed may be suitable for this product:
Outdoor use, uses involving potential chemical contamination or
electrical interference, or conditions or uses not described in this
catalog.
Nuclear energy control systems, combustion systems, railroad sys-
tems, aviation systems, medical equipment, amusement machines,
vehicles, safety equipment, and installations subject to separate
industry or government regulations.
Systems, machines and equipment that could present a risk to life
or property.
Please know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING
THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS OMRON shall not be responsible
for the users programming of a programmable product, or any con-
sequence thereof.
DISCLAIMERS
PERFORMANCE DATA Performance data given in this catalog is
provided as a guide for the user in determining suitability and does
not constitute a warranty. It may represent the result of OMRON’s
test conditions, and the user must correlate it to actual application
requirements. Actual performance is subject to the OMRON War-
ranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS Product specifications and accesso-
ries may be changed at any time based on improvements and other
reasons. It is our practice to change part numbers when published
ratings or features are changed, or when significant construction
changes are made. However, some specifications of the product may
be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your appli-
cation. Please consult with your OMRON representative at any time
to confirm actual specifications of purchased product.
ERRORS AND OMISSIONS The information in this catalog has
been carefully checked and is believed to be accurate; however, no
responsibility is assumed for clerical, typographical or proofreading
errors, or omissions.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.ca
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
Cat. No. GC RFID 4 Printed in USA
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
416-286-6465
OMRON ELECTRONICS LLC
One Commerce Drive
Schaumburg, IL 60173
847-843-7900
For US technical support or other inquiries:
800-556-6766
5/03 Specifications subject to change without notice
Complete terms and conditions for product purchase and use are on Omron’s website at
www.omron.com/oei under the About Us” tab, in the Legal Matters section.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
XW2Z-500P XW2Z-200S XW2Z-500S