Du line
®
Fieldbus Installationbus
Specifications are subject to change without notice (05.05.03) 1
Dupline®is a registered trademark. A product of the CARLO GAVAZZI Group
Type: Dupline®
H4-Housing
Combined module
Interface type
DC supply
Interface for Omron PLC with the function of a master
Plug and play: Automatic communication with specific
PLC/Controllers
Built-in normal Dupline®Channel Generator
128 I/O’s and DC power supply on 3 wires
RS232/RS422/RS485 port for interfacing to control
system
Split-I/O mode selectable (128 inputs and 128 outputs)
LED-indications for supply, Dupline®carrier and Com-
port Tx
Galvanically isolated Com-port supplied by internal
DC/DC converter
Product Description Ordering Key
G 3496 0004 is designed as a
cost-effective solution for
interfacing Dupline®I/O’s to a
Omron PLC. It performs three
functions: Dupline®channel
generator, power supply syn-
chronization (enables 3-wire
system with supply) and
RS232/RS422/RS485 inter-
face.
Type Selection
Supply PLC Interface Conformance Ordering no.
20-30 VDC Omron CPM, CPM1A, CQM, SRM1 & C200 G 3496 0004 700
G 3496 0004 700
Input/Output Specifications
Dupline®Plug & Play Master Module
Interface for Omron
Power output
Output voltage 20-30 VDC (pulsating)
Output current < 3.0 A @ 50ºC
Short circuit protection 4 A quick acting fuse
Output voltage drop < 1.0 V
Dupline®carrier
Output voltage 8.2 V (pulsating)
Current < 60 mA
Short circuit protection Yes
Scan time
128 channels 132.2 ms
64 channels 69.8 ms
Communication port
Standard RS232/RS422/RS485
Split I/O mode Yes, selectable
Normal Dupline mode Yes, selectable
Connection 9 pole female Sub-D
Dielectric voltage
Com-port Dupline®1 kVAC (rms)
Protocol HostLink
Baud rate 9600 (Omron Default)
19200
Data bits 7
Start bit 1
Stop bit 2
Parity Even
Flow-control None
Type G 3496 0004
Input/Output Specifications (Cont.)
Pin assignment
2-wire RS 485
S/R Data line + (B) Pin 3
S/R Data line - (A) Pin 8
GND Pin 5
4-wire RS 485/RS 422
R Data line + (B) Pin 3
R Data line - (A) Pin 8
S Data line + (B) Pin 2
S Data line - (A) Pin 7
Direction Pin 4
(Connect to GND pin 5
when using 4-wire commu-
nication)
RS 232
TX Pin 1
RX Pin 9
GND Pin 5
Supply Specifications
Power supply
Overvoltage cat. III (IEC 60664)
Operational voltage (Vin) 20-30 VDC
Reverse polarity protection None
Current consumption < 150 mA + Power load
Power dissipation < 5 W
Transient protection voltage 800 V
Dielectric voltage
Supply - Dupline®None
Supply - com-port 1 kVAC (rms)
Power ON delay 2 s
Indication for
Com-port Tx LED, red
Supply ON LED, green
Dupline®carrier LED, yellow
Environment
Pollution degree 3 (IEC 60664)
Operating temperature to +50°C (+32° to +122°F)
Storage temperature
-50° to +85°C (-58° to +185°F)
Du line
®
Fieldbus Installationbus
2Specifications are subject to change without notice (12.01.01)
Dupline®is a registered trademark. A product of the CARLO GAVAZZI Group
Mode of Operation
The Dupline
®
Master Module
(DMM) controls a 3-wire bus
with signal, DC-power and
common GND. The DMM is
connected to a standard DC-
supply, which it synchronizes
with the Dupline
®
carrier signal
before it is output to supply.
The synchronization is neces-
sary in order to enable the
Dupline
®
and DC-supply to
share the GND-wire.
The Dupline
®
Master Module is
a Dupline
®
Channel Generator
with the function of a master.
This means that the 128
Dupline
®
I/O’s will be read/writ-
ten by the DMM and then sent
to the PLC.
The DMM can run in two dif-
ferent modes – Normal mode
and split I/O mode. In Normal
mode, Dupline
®
operates as a
peer-to-peer system, where
the channel generator auto-
matically establishes a con-
nection between Dupline
®
inputs and Dupline
®
outputs
which are coded to the same
Dupline
®
address. If e.g. an
input coded for B5 is activat-
ed, the output(s) coded for B5
will also be activated.
Consequently, a Dupline
®
-out-
put can either be activated
through the output-data
received on DMM or by an
active Dupline
®
input coded
for the same Dupline
®
-
address. In “Split I/O” mode,
the channel generator treats
the Dupline
®
inputs and
Dupline
®
outputs indepen-
dently. If e.g. an input coded
for B5 is activated, the DMM
will make the information avail-
able for the PLC (like in normal
mode), but it will not automati-
cally activate the Dupline
®
out-
put(s) coded to B5. The
Dupline
®
outputs are con-
trolled exclusively through the
output data received from the
PLC. In this mode, up to 128
Dupline
®
inputs and 128
Dupline
®
outputs are available,
since an input and an output
coded to the same Dupline
®
address can operate indepen-
dently.
G 3496 0004
General Specifications
Humidity (non-condensing) 20 to 80%
Mechanical resistance
Shock 15 G (11 ms)
Vibration 2 G (6 to 55 Hz)
Dimensions H4-Housing
Material (see Technical information)
Weight 100 g
Dip-Switch Setting
Sw.3 On: 19200 baud
Off: 9600 baud (Default Omron setting)
Sw.4 On: Split I/O Channel Generator Mode
(See “Mode of Operation”)
Off: Normal Dupline
®
Monostable Channel
Generator Mode
Sw.5 On: 64 Dupline
®
channels
Off: 128 Dupline
®
channels
Memory Mapping
Dupline®Omron Dupline®Omron
Channel Channel
Read Write Read Write
A1 LR0000 LR0800 E1 LR0200 LR1000
A2 LR0001 LR0801 F1 LR0208 LR1008
A3 LR0002 LR0802 G1 LR0300 LR1100
A4 LR0003 LR0803 H1 LR0308 LR1108
A5 LR0004 LR0804 I1 LR0400 LR1200
A6 LR0005 LR0805 J1 LR0408 LR1208
A7 LR0006 LR0806 K1 LR0500 LR1300
A8 LR0007 LR0807 L1 LR0508 LR1308
B1 LR0008 LR0808 M1 LR0600 LR1400
B8 LR0015 LR0815 N1 LR0608 LR1408
C1 LR0100 LR0900 O1 LR0700 LR1500
D1 LR0108 LR0908 P1 LR0708 LR1508
Table of the memory mapping to the PLC
Wiring Diagram
1234
21 22 27 28
Supply in
20-30 V DC
24
23
678
5
26
25
+-
Power out
GND
Dupline Signal
RS 232
RS 485
3W
Du line
®
Fieldbus Installationbus
Specifications are subject to change without notice (12.01.01) 3
Dupline®is a registered trademark. A product of the CARLO GAVAZZI Group
Installation Hints
IMPORTANT
The PLC must be in Monitor-mode. Termination switch on
CIF11 must be in OFF position
TX-LED
Slow flashing No communication
Check the wiring.
Fast flashing Communication OK.
No Dupline®Carrier-LED
Dupline®Short curcuit Short curcuit between the
two Dupline®wires.
Accessories
Through Com. Module
Cable Sub-D 9M/6Wires for Com.
Module with Screw term. RS-422-OM1
Peripheral Port
Cable Sub-D 9M/SCSI RS-422-OM2
Additional Information
Scope of supply
1 x Master Module G3496 0004 700
Pin Assignment
1
9
8
7
6
5
4
3
2
8
6
5
4
3SDB
RDB
SDA
SG
RDA
+ 5 Vin (G 2196 0004 only)
7
2
G 2196 0004
G 3496 0004
RS-422-OM1
CIF11
G 3496 0004
1
9
8
7
6
5
4
3
2
OMRON SCSI
plug 20 pol
Pink 1 - Red
Pink 1 - Black
Orange 1 - Red
Orange 1 - Black
Grey 1 - Red
Grey 1 - Black
White 1 - Red
White 1 - Black
Yellow 1 - Red
Pink 2 - Red
Pink 2 - Black
Grey 2 - Red
Grey 2 - Black
White 2 - Red
White 2 - Black
Yellow 2 - Red
RS-422-OM2