2c GdsA-2C DIN 41612 -VG 95 324 - complementary to type C Number of contacts 48, 32, Male connectors Identification Male connector with angled solder pins Male connector with straight solder pins Male connector with angled press-in terminations Dimensions Board drillings 36 16 Number of contacts 48 Contact arrangement 1226 eooe |. 1234 ae ne s ae Part Nos. and versions see "har: press catalogue Part No. 3 09 23 148 7921 09 23 132 7921 09 23 116 7931 09 23 1487951 09 23 148 7922 09 23 132 7922 09 23 116 7932 09 23 148 7952 Angled solder pins ge LF i : J if) 7 eo 87 LL abs 16 15 21 ae S| woteeee oy i 5} eee ee ] 3h PeSSHESEHOEFO ROHS lea ay te 2 $5 P15 (250-883 208 48,2601 4 Male connectors with 2 first mating contacts {(0.8 mm) pos. a1 and a16]" Male connectors with contacts in other positions/other rows on request Performance levels according to DIN 41612, explanations page 10 2 09 23 1486921 09 23 132 6921 09 23 1166931 09 23 148 6951 09 23 148 6922 09 23 1326922 0923 1166932 09 23 148 6952 Straight solder pins ome wa 1 09 23 148 2921" 09 23 132 2921* 09 23 116 2931* 09 23 148 2951" 09 23 148 2922 09 23 132 2922 09 23 116 2932 09 23 148 2952" Dimensions in mm Not normally kept in stock10 Gds A DIN 41612 - VG 95 324 Si Performance level 3 as per DIN 41 612, part Soldering the male connectors into P.C. Boards 50 mating cycles. The male connectors of the Gds A series should be protected when Then visualinspection nogastest. ; soldering using dip, fiow or film soldering baths, against contamination No functional impairment. as a result of soldering operations or deformation of the connector Part-number-explanation roo! oo fd 7 bodies as a result of overheating. @ For prototypes and short runs cover the connectors with an industrial Performance level 2 as per DIN 41 612, part 5 adhesive tape, e.g. Tesaband 4657 grey. Tape the underside of the ; connector mouiding and adjacent parts of the P.C. Board and tape up 400 mating cycles. ; the open end of the connector. This will prevent heat and gases from 200 mating cycles 4 days gas test using 10 ppm SO2. the soldering apparatus damaging the connector. About 140 + 5mm Measurement of contact resistance. of tape should be sufficient 200 mating cycles then visual inspection. No abrasion of the : contact finish through to the base material. @ For large run production a jig is recommended. This has a protective No functional impairment. cover with a fast action mechanical locking device that shields the connector from the gas and heat generated by the soldering ap- Part-number-explanation [09 | ( Cj} 6 paratus. For additional protection a foil can be used covering parts not to be soldered. Performance level 1 as per DIN 41612, part 5 500 mating cycles. 250 mating cycles 21 days gas test using 10 ppm SOz. Measurement of contact resistance. 250 mating cycles then visual inspection. No abrasion of the contact finish through to the base material. No functional impairment. a ae) Part-number-explanation CIE) 2) Je VG Version as per VG 95 324, part 1 Adhesive tape 500 mating cycles then 1 day gas test using 10.000 ppm SO, and 1 day gas test using 10.000 ppm H2S. @ Then visual inspection. No abrasion of the contact finish through to the base material. No functional impairment. Part-number-explanation Co LE ] cn Other plating finishes available on request. Ce oO Mating conditions To ensure reliable connections and prevent unnecessary damage, please refer to the application data diagrams. Intermediate foil These recommendations are set out in DIN 41 612 P. 1. The connectors shall not be coupled and decoupled under electrical load. 24 +2 g =124-14,2GdsA DIN 41612: VG 95324 (i) Identification Part No. Drawing Dimensions inmm Coding system Code pin To avoid accidental incorrect mating of adjacent connectors with loss of Gds A-B, A-2 B, a coding system is required. Coding is effected-by means of contact GdsA-C, A-2C, a code pin to be inserted into the selected chamber of the female Gds A-CH, A-M, connector (contact cavity must be filled!). The opposite male Gds A-Q, A-2 Q, contact must be removed by means of a specially designed tool. Gds A-R, A-2R 09 02 000 9901 == Plastic Removal-tool for maie contacts 09 99 000 0133 Ga Code pin Gds A-D, A-E, Gds A-F/FC Gds A-FM, Gds A-2F/FC, Gds A-MH 09 04 000 9908 SFE F Past Removal-tool for male contacts 09 99 000 0038 At the position desired a hole has to be drilled at one of the marked points between the contacts-rows of the male connector (see also drawing). Coding system The code pin can then be inserted into the opposing bore of the female without loss of connector by means of an insertion-tool. contact This coding system is at present only applicable for Gds A-D, Gds A-E, . Gds A-F/FC and interface connectors | Gds A-F/FC. with code pin Code pin a Metal 09 06 000 9950 Meta Insertion tool emacs 0999 000 0103 Mounting example t- Code pin a Code pin #1 216 ry 3 ~ v ~t YO AA j L_ SSS $00 GdsA-D, GdsA-E 1938 Gds A-F/FC shroud coding Insert the code key into one of the keyways in the female connector. Code key Break out the corresponding area of the male shroud. Connectors utilising this coding method can only be used at a minimum Gds A-F/FC 09 06 001 9919 rack spacing of 20.32 mm. Gds A-H, MH 09 06 001 9918 Gds A-H Gds A-MH 88