1
Cylindrical Proximity Sensor
E2B
Perfect fit
for standard environments
Embody two seemingly contradictory characteristics: value-for-
money and high reliability
All 372 Models
F our different sizes: M8, M12, M18 and M30
Single and double sensing distances, Shielded and unshielded
A choice of short and long bodies, two connecting methods and four
output types
Operating temperature: –25°C to 70°C
Water resistance: IP67
With an all-round 360° visible indicator
Features
Wide Variation
“Double Distance” Close at Hand
Perfect Fit to Your Application Needs
With no less than 372 models in the family.
You can choose the one that exactly meets your needs.
E2B series can save cost & your time via single source.
Reliable Performance
360-degree indication
Easy visibility for 360° even in
dark locations so you can mount
the sensor in any direction.
* The 360-degree indication is only for
Pre-wired Models of M12, M18 , and
M30.
* The other models (Pre-wired Models
of M8 and all the Connecto r Models)
have 4 LEDs at 90-degree int ervals,
which realize clear visibility from a
360-degree angle.
Oil-mist env ir onment resistan t!
IP67
We have performed not only a specified
test for rating the degree of protection
(IP67) for catalogs, but also tests with oil mist which appears onsite.
Simulation tests has been performed with attachment of high
concentration of oil mist.
*1. There are so many kinds of E2E, not all IP69K rated. In detailed part#,
please contact your OMRON representative.
0 5 10 15 20 25 30
4mm
8mm
16mm
30mm
Sensing distance
S
ensing distances of unshielded model
s
Wide range of size
Short/
Long Bodies
Long body for easy
adjustment after mounting
Output configuration:
PNP/NPN Operation mode:
NO/NC
Shielded/
Unshielded
Shielded models for
better noise immunity
Connectors for easy maintenance
×1
×1
×
2
×1
×1
×2
×1
×1
×
2
2
×1
×
2
8
8
8
8
2
8
8
8
0
0
With the double distance, you can get
almost the same sensing distance with a
sensor that is one size smaller.
Pre-wired/
Connectors
Lineup of models from
M8 to M30 Models available with standard distance(×1) and double distance (×2)
“Double distance” saves space and
reduces costs
M18 M12
×1 ×2
nsh
ield
ed
U
cto
rs
n
e
Conn
M
8
M
8
M
M1
1
M
M1
1
M
M1
1
M
M1
1
M
M1
1
M
M3
3
0
M
M3
3
0
Single
distance
(×1)
Double
distance
(×2)
Degree of
Protection E2B E2E
(M8/M12/M18/
M30 size)
Small Dia E2E
(3 dia./4 dia./
6.5 dia/M4/M5)
Water
resistance IP67 IP67
IP69K *1 IP67
Oil
resistance
In oil-mist of solu-
ble cutting oil dilut-
ed, 250 hours, the
temperature of at-
mosphere is 23°C
Soaked in oil (solu-
ble type and insol u-
ble) 500 hours,
temperature of oil
50°C
Soaked in insoluble
oil 250 hours, tem-
perature of oil 50°C
A
l
l
a
r
o
u
n
d
V
i
s
i
b
l
e
A
l
l
a
r
o
u
n
d
V
i
s
i
b
l
e
10 cm
under 10 cm
under
E2B
2
Ordering Information
Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
2. Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).
Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
2. There are restrictions that apply to Shielded sensors.
Please refer to “Effects of Surrounding Metal” on page 20.
Size Sensing
distance
Connecting
method
(See no t e 1 .)
Body
length Output
configuration Operation mode NO Operation mode NC
M8
(Stainless steel)
(See note 2.)
Single
Shielded
Pre-wired Short PNP E2B-S08KS01-WP-B1 2M E2B-S08KS01-WP-B2 2M
NPN E2B-S08KS01-WP-C1 2M E2B-S08KS01-WP-C2 2M
Long PNP E2B-S08LS01-WP-B1 2M E2B-S08LS01-WP-B2 2M
NPN E2B-S08LS01-WP-C1 2M E2B-S08LS01-WP-C2 2M
M8 Connec-
tor (3-pin)
Short PNP E2B-S08KS01-MC-B1 E2B-S08KS01-MC-B2
NPN E2B-S08KS01-MC-C1 E2B-S08KS01-MC-C2
Long PNP E2B-S08LS01-MC-B1 E2B-S08LS01-MC-B2
NPN E2B-S08LS01-MC-C1 E2B-S08LS01-MC-C2
Unshielded
Pre-wired Short PNP E2B-S08KN02-WP-B1 2M E2B-S08KN02-WP-B2 2M
NPN E2B-S08KN02-WP-C1 2M E2B-S08KN02-WP-C2 2M
Long PNP E2B-S08LN02-WP-B1 2M E2B-S08LN02-WP-B2 2M
NPN E2B-S08LN02-WP-C1 2M E2B-S08LN02-WP-C2 2M
M8 Connec-
tor (3-pin)
Short PNP E2B-S08KN02-MC-B1 E2B-S08KN02-MC-B2
NPN E2B-S08KN02-MC-C1 E2B-S08KN02-MC-C2
Long PNP E2B-S08LN02-MC-B1 E2B-S08LN02-MC-B2
NPN E2B-S08LN02-MC-C1 E2B-S08LN02-MC-C2
Double
Shielded
Pre-wired Short PNP E2B-S08KS02-WP-B1 2M E2B-S08KS02-WP-B2 2M
NPN E2B-S08KS02-WP-C1 2M E2B-S08KS02-WP-C2 2M
Long PNP E2B-S08LS02-WP-B1 2M E2B-S08LS02-WP-B2 2M
NPN E2B-S08LS02-WP-C1 2M E2B-S08LS02-WP-C2 2M
M8 Connec-
tor (3-pin)
Short PNP E2B-S08KS02-MC-B1 E2B-S08KS02-MC-B2
NPN E2B-S08KS02-MC-C1 E2B-S08KS02-MC-C2
Long PNP E2B-S08LS02-MC-B1 E2B-S08LS02-MC-B2
NPN E2B-S08LS02-MC-C1 E2B-S08LS02-MC-C2
Unshielded
Pre-wired Short PNP E2B-S08KN04-WP-B1 2M E2B-S08KN04-WP-B2 2M
NPN E2B-S08KN04-WP-C1 2M E2B-S08KN04-WP-C2 2M
Long PNP E2B-S08LN04-WP-B1 2M E2B-S08LN04-WP-B2 2M
NPN E2B-S08LN04-WP-C1 2M E2B-S08LN04-WP-C2 2M
M8 Connec-
tor (3-pin)
Short PNP E2B-S08KN04-MC-B1 E2B-S08KN04-MC-B2
NPN E2B-S08KN04-MC-C1 E2B-S08KN04-MC-C2
Long PNP E2B-S08LN04-MC-B1 E2B-S08LN04-MC-B2
NPN E2B-S08LN04-MC-C1 E2B-S08LN04-MC-C2
Size Sensing
distance
Connecting
method
(See no t e 1 .)
Body
length Output
configuration Operation mode NO Operation mode NC
M12 (Brass)
Single
Shielded
Pre-wired Short PNP E2B-M12KS02-WP-B1 2M E2B-M12KS02-WP-B2 2M
NPN E2B-M12KS02-WP-C1 2M E2B-M12KS02-WP-C2 2M
Long PNP E2B-M12LS02-WP-B1 2M E2B-M12LS02-WP-B2 2M
NPN E2B-M12LS02-WP-C1 2M E2B-M12LS02-WP-C2 2M
M12
Connector
Short PNP E2B-M12KS02-M1-B1 E2B-M12KS02-M1-B2
NPN E2B-M12KS02-M1-C1 E2B-M12KS02-M1-C2
Long PNP E2B-M12LS02-M1-B1 E2B-M12LS02-M1-B2
NPN E2B-M12LS02-M1-C1 E2B-M12LS02-M1-C2
Unshielded
Pre-wired Short PNP E2B-M12KN05-WP-B1 2M E2B-M12KN05-WP-B2 2M
NPN E2B-M12KN05-WP-C1 2M E2B-M12KN05-WP-C2 2M
Long PNP E2B-M12LN05-WP-B1 2M E2B-M12LN05-WP-B2 2M
NPN E2B-M12LN05-WP-C1 2M E2B-M12LN05-WP-C2 2M
M12
Connector
Short PNP E2B-M12KN05-M1-B1 E2B-M12KN05-M1-B2
NPN E2B-M12KN05-M1-C1 E2B-M12KN05-M1-C2
Long PNP E2B-M12LN05-M1-B1 E2B-M12LN05-M1-B2
NPN E2B-M12LN05-M1-C1 E2B-M12LN05-M1-C2
Double
Shielded
(See note 2.)
Pre-wired Short PNP E2B-M12KS04-WP-B1 2M E2B-M12KS04-WP-B2 2M
NPN E2B-M12KS04-WP-C1 2M E2B-M12KS04-WP-C2 2M
Long PNP E2B-M12LS04-WP-B1 2M E2B-M12LS04-WP-B2 2M
NPN E2B-M12LS04-WP-C1 2M E2B-M12LS04-WP-C2 2M
M12
Connector
Short PNP E2B-M12KS04-M1-B1 E2B-M12KS04-M1-B2
NPN E2B-M12KS04-M1-C1 E2B-M12KS04-M1-C2
Long PNP E2B-M12LS04-M1-B1 E2B-M12LS04-M1-B2
NPN E2B-M12LS04-M1-C1 E2B-M12LS04-M1-C2
Unshielded
Pre-wired Short PNP E2B-M12KN08-WP-B1 2M E2B-M12KN08-WP-B2 2M
NPN E2B-M12KN08-WP-C1 2M E2B-M12KN08-WP-C2 2M
Long PNP E2B-M12LN08-WP-B1 2M E2B-M12LN08-WP-B2 2M
NPN E2B-M12LN08-WP-C1 2M E2B-M12LN08-WP-C2 2M
M12
Connector
Short PNP E2B-M12KN08-M1-B1 E2B-M12KN08-M1-B2
NPN E2B-M12KN08-M1-C1 E2B-M12KN08-M1-C2
Long PNP E2B-M12LN08-M1-B1 E2B-M12LN08-M1-B2
NPN E2B-M12LN08-M1-C1 E2B-M12LN08-M1-C2
1.5 mm
2 mm
2 mm
4 mm
2 mm
5 mm
4 mm
8 mm
3
E2B
Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
2. There are restrictions that app ly to Shielded sensors.
Please refer to “Effects of Surrounding Metal” on page 20.
Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m.
2. There are restrictions that app ly to Shielded sensors.
Please refer to “Effects of Surrounding Metal” on page 20.
Size Sensing
distance
Connecting
method
(See note 1.)
Body
length Output
configuration Operation mode NO Operation mode NC
M18 (Brass)
Single
Shielded
Pre-wired Short PNP E2B-M18KS05-WP-B1 2M E2B-M18KS05-WP-B2 2M
NPN E2B-M18KS05-WP-C1 2M E2B-M18KS05-WP-C2 2M
Long PNP E2B-M18LS05-WP-B1 2M E2B-M18LS05-WP-B2 2M
NPN E2B-M18LS05-WP-C1 2M E2B-M18LS05-WP-C2 2M
M12
Connector
Short PNP E2B-M18KS05-M1-B1 E2B-M18KS05-M1-B2
NPN E2B-M18KS05-M1-C1 E2B-M18KS05-M1-C2
Long PNP E2B-M18LS05-M1-B1 E2B-M18LS05-M1-B2
NPN E2B-M18LS05-M1-C1 E2B-M18LS05-M1-C2
Unshielded
Pre-wired Short PNP E2B-M18KN10-WP-B1 2M E2B-M18KN10-WP-B2 2M
NPN E2B-M18KN10-WP-C1 2M E2B-M18KN10-WP-C2 2M
Long PNP E2B-M18L N 1 0- WP-B1 2M E2B-M18LN10-WP-B2 2M
NPN E2B-M1 8 L N10-WP-C 1 2 M E2B-M1 8LN10-WP -C2 2M
M12
Connector
Short PNP E2B-M18KN10-M1-B1 E2B-M18KN10-M1-B2
NPN E2B-M18KN10-M1-C1 E2B-M18KN10-M1-C2
Long PNP E2B-M18LN10-M1-B1 E2B-M18LN10-M1-B2
NPN E2B-M18LN10-M1-C1 E2B-M18LN10-M1-C2
Double
Shielded
(See note 2.)
Pre-wired Short PNP E2B-M18KS08-WP-B1 2M E2B-M18KS08-WP-B2 2M
NPN E2B-M18KS08-WP-C1 2M E2B-M18KS08-WP-C2 2M
Long PNP E2B-M18LS08-WP-B1 2M E2B-M18LS08-WP-B2 2M
NPN E2B-M18LS08-WP-C1 2M E2B-M18LS08-WP-C2 2M
M12
Connector
Short PNP E2B-M18KS08-M1-B1 E2B-M18KS08-M1-B2
NPN E2B-M18KS08-M1-C1 E2B-M18KS08-M1-C2
Long PNP E2B-M18LS08-M1-B1 E2B-M18LS08-M1-B2
NPN E2B-M18LS08-M1-C1 E2B-M18LS08-M1-C2
Unshielded
Pre-wired Short PNP E2B-M18KN16-WP-B1 2M E2B-M18KN16-WP-B2 2M
NPN E2B-M18KN16-WP-C1 2M E2B-M18KN16-WP-C2 2M
Long PNP E2B-M18L N 1 6- WP-B1 2M E2B-M18LN16-WP-B2 2M
NPN E2B-M1 8 L N16-WP-C 1 2 M E2B-M1 8LN16-WP -C2 2M
M12
Connector
Short PNP E2B-M18KN16-M1-B1 E2B-M18KN16-M1-B2
NPN E2B-M18KN16-M1-C1 E2B-M18KN16-M1-C2
Long PNP E2B-M18LN16-M1-B1 E2B-M18LN16-M1-B2
NPN E2B-M18LN16-M1-C1 E2B-M18LN16-M1-C2
Size Sensing
distance
Connecting
method
(See note 1.)
Body
length Output
configuration Operation mode NO Operation mode NC
M30 (Brass)
Single
Shielded
Pre-wired Short PNP E2B-M30KS10-WP-B1 2M E2B-M30KS10-WP-B2 2M
NPN E2B-M30KS10-WP-C1 2M E2B-M30KS10-WP-C2 2M
Long PNP E2B-M30LS10-WP-B1 2M E2B-M30LS10-WP-B2 2M
NPN E2B-M30LS10-WP-C1 2M E2B-M30LS10-WP-C2 2M
M12
Connector
Short PNP E2B-M30KS10-M1-B1 E2B-M30KS10-M1-B2
NPN E2B-M30KS10-M1-C1 E2B-M30KS10-M1-C2
Long PNP E2B-M30LS10-M1-B1 E2B-M30LS10-M1-B2
NPN E2B-M30LS10-M1-C1 E2B-M30LS10-M1-C2
Unshielded
Pre-wired Short PNP E2B-M30KN20-WP-B1 2M E2B-M30KN20-WP-B2 2M
NPN E2B-M30KN20-WP-C1 2M E2B-M30KN20-WP-C2 2M
Long PNP E2B-M30L N 2 0- WP-B1 2M E2B-M30LN20-WP-B2 2M
NPN E2B-M3 0 L N20-WP-C 1 2 M E2B-M3 0LN20-WP -C2 2M
M12
Connector
Short PNP E2B-M30KN20-M1-B1 E2B-M30KN20-M1-B2
NPN E2B-M30KN20-M1-C1 E2B-M30KN20-M1-C2
Long PNP E2B-M30LN20-M1-B1 E2B-M30LN20-M1-B2
NPN E2B-M30LN20-M1-C1 E2B-M30LN20-M1-C2
Double
Shielded
(See note 2.)
Pre-wired Short PNP E2B-M30KS15-WP-B1 2M E2B-M30KS15-WP-B2 2M
NPN E2B-M30KS15-WP-C1 2M E2B-M30KS15-WP-C2 2M
Long PNP E2B-M30LS15-WP-B1 2M E2B-M30LS15-WP-B2 2M
NPN E2B-M30LS15-WP-C1 2M E2B-M30LS15-WP-C2 2M
M12
Connector
Short PNP E2B-M30KS15-M1-B1 E2B-M30KS15-M1-B2
NPN E2B-M30KS15-M1-C1 E2B-M30KS15-M1-C2
Long PNP E2B-M30LS15-M1-B1 E2B-M30LS15-M1-B2
NPN E2B-M30LS15-M1-C1 E2B-M30LS15-M1-C2
Unshielded Pre-wired Long PNP E2B-M3 0 L N30-WP-B 1 2 M E2B-M3 0LN30-WP -B2 2M
NPN E2B-M3 0 L N30-WP-C 1 2 M E2B-M3 0LN30-WP -C2 2M
M12
Connector Long PNP E2B-M30LN30-M1-B1 E2B-M30LN30-M1-B2
NPN E2B-M30LN30-M1-C1 E2B-M30LN30-M1-C2
5 mm
10 mm
8 mm
16 mm
10 mm
20 mm
15 mm
30 mm
E2B
4
Accessories (Order Separately)
Sensor I/O Connectors
Size Cable Shape Cores Cable length (m) Model
M8 (3-pin)
PVC Straight
3
2XS3F-B8PVC3S2M
5XS3F-B8PVC3S5M
Right-angle 2XS3F-B8PVC3A2M
5XS3F-B8PVC3A5M
PVC Robot Straight 2XS3F-M321-302-R
5XS3F-M321-305-R
Right-angle 2XS3F-M322-302-R
5XS3F-M322-305-R
M12 (4-pin)
PVC Straight
4
2XS2F-B12PVC4S2M
5XS2F-B12PVC4S5M
Right-angle 2XS2F-B12PVC4A2M
5XS2F-B12PVC4A5M
PVC Robot Straight 2XS2F-D421-D80-F
5XS2F-D421-G80-F
Right-angle 2XS2F-D422-D80-F
5XS2F-D422-G80-F
5
E2B
Model Number Legend
Example:E2B-M12LS04-M1-B1 M12, Brass, Long body, Shielded, Sn = 4 mm, M12 connector, PNP, NO
E2B-S08KN02-WP-C2 5M M8, stainless steel, Short body, Unshielded, Sn = 2 mm, Pre-wired PVC cable, NPN, NC,
Cable length = 5 m
1. Basic name
E2B
2. Housing shape and material
M: Cylindrical, metric threaded, brass
S: Cylindrical, metric threaded, stainless steel
3. Housing size
08: 8 mm
12: 12 mm
18: 18 mm
30: 30 mm
4. Barrel length
K: Short body
L: Long body
5. Shield
S: Shielded
N: Unshielded
6. Sensing distance
Numeral: Sensing distance:
01 = 1.5 mm, 02 = 2 mm, 04 = 4 mm, 05 = 5 mm,
08 = 8 mm, 10 = 10 mm, 15 = 15 mm, 16 = 16 mm,
20 = 20 mm, 30 = 30 mm
7. Kind of connection
WP: Pre-wired, PVC, dia 4 mm
M1: M12 connector
MC: M8 connector (3 pin)
8. Power source and output
B: PNP
C: NPN
9. Operation mode
1: NO (Normally open)
2: NC (Normally closed)
10.Cable length
Blank: Connector type
Numeral: Cable length (2M and 5M are available.)
132 4 5 6 7 8 9 10
E2B-@@@@@-@-@@ @
E2B
6
Ratings and Specifications
Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensin g object, a distance of twice the standard sensing object
between sensing objects, and a setting distance of half the sensing distance.
2. When using any model of M8 size a t an ambient temperature between -25°C and 60°C, use a load current of 200 mA max., at an ambie nt temperature between
60°C and 70°C, use a load current of 100 mA max.
Item
Size M8
Sensing
distance Single Double
Type Shielded Unshielded Shielded Unshielded
Model E2B-S08@S01 E2B-S08@N02 E2B-S08@S02 E2B-S08@N04
Sensing distance 1.5 mm ± 10% 2 mm ± 10% 2 mm ± 10% 4 mm ± 10%
Setting distance 0 to 1.2 mm 0 to 1.6 mm 0 to 1.6 mm 0 to 3.2 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard sensing object
(mild steel ST37) 8 × 8 × 1 mm 8 × 8 × 1 mm 8 × 8 × 1 mm 12 × 12 × 1 mm
Response frequency (See note 1.) 2,000 Hz 1,000 Hz 1,500 Hz 1,000 Hz
Power supply voltage 10 to 30 VDC. (including 10% ripple (p-p))
Current consumption 10 mA max.
Output type -B models: PNP open collector
-C models: NPN open collector
Control output Load current
(See note 2.) 200 mA max. (30 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode
(with sensing object approaching) -B1/-C1 models: NO
-B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Short-circuit protection
Ambient air temperature Operation and storage : -25 to 70°C (with no icing or condensation)
Temperature influence
(See note 2.) ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C
±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C
Ambient humidity Operation and Storage: 35 to 95%
Voltage influence ±1% max. of sensing distance in 24 V ±15%
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 500 m/s2, 10 times each in X, Y and Z directions
Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Connecting method Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
Connector models (M8-3pin)
Weight
(packaged) Pre-wired model Short body: Approx. 65 g, Long body: Approx. 65 g
Connector model Short body: Approx. 20 g, Long body: Approx. 20 g
Material
Case Stainless steel (1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS).)
Sensing surface PBT
Cable Standard cable is 4 mm dia. PVC.
Clamping nut Brass-nickel plated
7
E2B
Note: 1. The response frequency is an average value. Measurement conditio ns are as follows: standard sensing object, a distance of twice the standard sensing object
between sensing objects, and a setting distance of half the sensing distance.
Item
Size M12
Sensing
distance Single Double
Type Shielded Unshielded Shielded Unshielded
Model E2B-M12@S02 E2B-M12@N05 E2B-M12@S04 E2B-M12@N08
Sensing distance 2 mm ± 10% 5 mm ± 10% 4 mm ± 10% 8 mm ± 10%
Setting distance 0 to 1.6 mm 0 to 4 mm 0 to 3.2 mm 0 to 6.4 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard sensing object
(mild steel ST37) 12 × 12 × 1 mm 15 × 15 × 1 mm 12 × 12 × 1 mm 24 × 24 × 1 mm
Response frequency (See note 1.) 1,500 Hz 800 Hz 1,000 Hz 800 Hz
Power supply voltage 10 to 30 VDC. (including 10% ripple (p-p))
Current consumption 10 mA max.
Output type -B models: PNP open collector
-C models: NPN open collector
Control output Lo ad current 200 mA max. (30 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode
(with sensing object approaching) -B1/-C1 models: NO
-B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Short-circuit protection
Ambient air temperature Operation and storage : -25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C
±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C
Ambient humidity Operation and Storage: 35 to 95%
Voltage influence ±1% max. of sensing distance in 24 V ±15%
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Connecting method Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
Connector models (M12-4pin)
Weight
(packaged) Pre-wired model Short body: Approx. 75 g, Long body: Approx. 80 g
Connector model Short body: Approx. 35 g, Long body: Approx. 40 g
Material
Case Brass-nickel plated
Sensing surface PBT
Cable Standard cable is 4 mm dia. PVC.
Clamping nut Brass-nickel plated
E2B
8
Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard sensin g object, a distance of twice the standard sensing object
between sensing objects, and a setting distance of half the sensing distance.
Item
Size M18
Sensing
distance Single Double
Type Shielded Unshielded Shielded Unshielded
Model E2B-M18@S05 E2B-M18@N10 E2B-M18@S08E2B-M18@N16
Sensing distance 5 mm ± 10% 10 mm ± 10% 8 mm ± 10% 16 mm ± 10%
Setting distance 0 to 4 mm 0 to 8 mm 0 to 6.4 mm 0 to 12.8 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard sensing object
(mild steel ST37) 18 × 18 × 1 mm 30 × 30 × 1 mm 24 × 24 × 1 mm 48 × 48 × 1 mm
Response frequency (See note 1.) 600 Hz 400 Hz 500 Hz 400 Hz
Power supply voltage 10 to 30 VDC. (including 10% ripple (p-p))
Current consumption 10 mA max.
Output type -B models: PNP open collector
-C models: NPN open collector
Control output Load current 200 mA max. (30 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode
(with sensing object approaching) -B1/-C1 models: NO
-B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Short-circuit protection
Ambient air temperature Operation and storage : -25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C
±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C
Ambient humidity Operation and Storage: 35 to 95%
Voltage influence ±1% max. of sensing distance in 24 V ±15%
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Connecting method Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
Connector models (M12-4pin)
Weight
(packaged) Pre-wired model Short body: Approx. 95 g, Long body: Approx. 110 g
Connector model Short body: Approx. 60 g, Long body: Approx. 80 g
Material
Case Brass-nickel plated
Sensing surface PBT
Cable Standard cable is 4 mm dia. PVC.
Clamping nut Brass-nickel plated
9
E2B
Note: 1. The response frequency is an average value. Measurement conditio ns are as follows: standard sensing object, a distance of twice the standard sensing object
between sensing objects, and a setting distance of half the sensing distance.
Item
Size M30
Sensing
distance Single Double
Type Shielded Unshielded Shielded Unshielded
Model E2B-M30@S10 E2B-M30@N20 E2B-M30@S15 E2B-M30@N30
Sensing distance 10 mm ± 10% 20 mm ± 10% 15 mm ± 10% 30 mm ± 10%
Setting distance 0 to 8 mm 0 to 16 mm 0 to 11.25 mm 0 to 22.5 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard sensing object
(mild steel ST37) 30 × 30 × 1 mm 60 × 60 × 1 mm 45 × 45 × 1 mm 90 × 90 × 1 mm
Response frequency (See note 1.) 400 Hz 100 Hz 250 Hz 100 Hz
Power supply voltage 10 to 30 VDC. (including 10% ripple (p-p))
Current consumption 10 mA max.
Output type -B models: PNP open collector
-C models: NPN open collector
Control output Lo ad current 200 mA max. (30 VDC max.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator Operation indicator (Yellow LED)
Operation mode
(with sensing object approaching) -B1/-C1 models: NO
-B2/-C2 models: NC
Protection circuit Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Short-circuit protection
Ambient air temperature Operation and storage : -25 to 70°C (with no icing or condensation)
Temperature influence ±10% max. of sensing distance at 23°C within temperature range of -10 to 55°C
±15% max. of sensing distance at 23°C within temperature range of -25 to 70°C
Ambient humidity Operation and Storage: 35 to 95%
Voltage influence ±1% max. of sensing distance in 24 V ±15%
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance 1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings (1) IP67 (IEC60529) (2) EMC (EN60947-5-2)
Connecting method Pre-wired models (standard is 4 mm dia. PVC cable with length = 2 m, 5 m).
Connector models (M12-4pin)
Weight
(packaged) Pre-wired model Short body: Approx. 160 g, Long body: Approx. 210 g
Connector model Short body: Approx. 140 g, Long body: Approx. 160 g
Material
Case Brass-nickel plated
Sensing surface PBT
Cable Standard cable is 4 mm dia. PVC.
Clamping nut Brass-nickel plated
E2B
10
Engineering Data (Reference Value)
Operating Range Influence of Sensing Object Size and Materia ls
Operating Range Influence of Sensing Object Size and Materia ls
M8Shielded Models Unshielded Models
M12 Shielded Models Unshielded Models
Sensing distance X (mm)
E2B-S08
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
Distance Y (mm)
XY
-8 -6 -4 -2 0 2 4 6 8
E2B-S08@S01
E2B-S08@N02
E2B-S08@N04
E2B-S08@S02
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-S08@S01
Sensing distance X (mm)
Side length of sensing object d (mm)
0 5 10 15 20 25
2.5
2
1.5
1
0.5
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-S08@N02
Sensing distance X (mm)
Side length of sensing object d (mm)
0 5 10 15 20 25 30
2.5
2
1.5
1
0.5
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-S08@S02
Sensing distance X (mm)
Side length of sensing object d (mm)
0 5 10 15 20 25
3
2.5
2
1.5
1
0.5
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-S08@N04
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70
6
5
4
3
2
1
E2B-M12@S04
E2B-M12@S02
E2B-M12@N05
Sensing distance X (mm)
E2B-M12
9
8
7
6
5
4
3
2
1
0
Distance Y (mm)
XY
-16 -12 -8 -4 0 4 8 12 16
E2B-M12@N08
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M12@S02
Sensing distance X (mm)
Side length of sensing object d (mm)
0 5 10 15 20 25
2.5
2
1.5
1
0.5
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M12@N05
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90
6
5
4
3
2
1
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M12@S04
Sensing distance X (mm)
Side length of sensing object d (mm)
0 5 10 15 20 25 30 35
5
4
3
2
1
Brass
Copper
Iron
Aluminium
t = 1
mm
X
@d
E2B-M12@N08
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90
9
8
7
6
5
4
3
2
1
Stainless steel (SUS304)
11
E2B
Operating Range Influence of Sensing Object Size and Materials
Operating Range Influence of Sensing Object Size and Materials
M18Shielded Models Unshielded Models
M30 Shielded Models Unshielded Models
Distance Y (mm)
Sensing distance X (mm)
E2B-M18
18
16
14
12
10
8
6
4
2
0
XY
-30 -20 -10 0 10 20 30
E2B-M18@S05
E2B-M18@S08
E2B-M18@N16
E2B-M18@N10
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M18@S05
Sensing distance X (mm)
Side length of sensing object d (mm)
6
5
4
3
2
1
0 10 20 30 40 50 60 70 80 90
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M18@N10
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90
12
10
8
6
4
2
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M18@S08
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90
9
8
7
6
5
4
3
2
1
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M18@N16
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90
18
16
14
12
10
8
6
4
2
Sensing distance X (mm)
E2B-M30
35
30
25
20
15
10
5
0
Distance Y (mm)
XY
-60 -40 -20 0 20 40 60
E2B-M30@S15
E2B-M30@S10
E2B-M30@N30
E2B-M30@N20
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M30@S10
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70
12
10
8
6
4
2
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M30@N20
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90 100
25
20
15
10
5
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M30@S15
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90 100
20
16
12
8
4
Brass
Copper
Iron
Stainless steel (SUS304)
Aluminium
t = 1
mm
X
@d
E2B-M30LN30
Sensing distance X (mm)
Side length of sensing object d (mm)
0 10 20 30 40 50 60 70 80 90 100
35
30
25
20
15
10
5
E2B
12
I/O Circuit Diagrams
PNP Output
Operation mode Model Timing chart Output circuit
NO
E2B-S08@-@-B@
NC
NO
E2B-M12@-@-B@
E2B-M18@-@-B@
E2B-M30@-@-B@
NC
Sensing
object
(%)100 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
3
14
M8 connector
(3 pin)
Pin Arrangement
Load
Brown
Black
Blue
10 to 30
VDC
main
circuits
1
3
4
(%)100 0
Sensing
object
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
Sensing
object
(%)100 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
3
1
24
M12 Connector
(4 pin)
Pin Arrangement
Brown
Black or
Blue
10 to 30
VDC
: NO
: NC
main
circuits
1
2
4
3
4
2
Load
(%)100 0
Sensing
object
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
13
E2B
NPN Output
Operation mode Model Timing chart Output circuit
NO
E2B-S08@-@-C@
NC
NO
E2B-M12@-@-C@
E2B-M18@-@-C@
E2B-M30@-@-C@
NC
Sensing
object
(%)100 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
3
14
M8 connector
(3 pin)
Pin Arrangement
Brown
Black
Blue
10 to 30
VDC
main
circuits
1
3
4
Load
(%)100 0
Sensing
object
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
Sensing
object
(%)100 0
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
3
1
24
M12 Connector
(4 pin)
Pin Arrangement
Brown
Black
Blue
10 to 30
VDC
main
circuits
1
3
4or 2
Load
: NO
: NC
4
2
(%)100 0
Sensing
object
Rated
sensing
distance
Sensing zoneNon-sensing zone
Proximity
Sensor
ON
OFF
ON
OFF
Yellow indicator
Control output
E2B
14
Dimensions
Note: All units are in millimeters unless otherwise indicated.
M8 Size
Pre-wired Models (Shielded)
Short Body Pre-wired Models (Unshielded)
Long Body
Connector Models (Shielded)
Short Body Connector Models (Unshielded)
Long Body
M8×1
Two,clamping nuts
Operating indicator
(yellow LED,4×90°)
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
13 27
4
42
E2B-S08KS01-WP-@@/E2B-S08KS02-WP-@@
M8×1
Operating indicator
(yellow LED,4×90°)
Two,clamping nuts
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
627
4
42
6.6 dia.
13
E2B-S08KN02-WP-@@/E2B-S08KN04-WP-@@
M8×1Two,clamping nuts
Operating indicator
(yellow LED,4×90°)
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
13 49
4
64
E2B-S08LS01-WP-@@/E2B-S08LS02-WP-@@
M8×1
Two,clamping nuts
Operating indicator
(yellow LED,4×90°)
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
13
6.6 dia.
49
4
64
6
E2B-S08LN02-WP-@@/E2B-S08LN04-WP-@@
M8×1 Two,clamping nuts
Operating indicator
(yellow LED,4×90°)
M8×1
27
4
44
13
E2B-S08KS01-MC-@@/E2B-S08KS02-MC-@@
13
M8×1
Two,clamping nuts
M8×1
Operating indicator
(yellow LED,4×90°)
6
44
27
4
6.6 dia.
E2B-S08KN02-MC-@@/E2B-S08KN04-MC-@@
M8×1
Operating indicator
(yellow LED,4×90°)
Two,clamping nuts M8×1
13 49
4
66
E2B-S08LS01-MC-@@/E2B-S08LS02-MC-@@
M8×1
Operating indicator
(yellow LED,4×90°)
Two,clamping nuts M8×1
13 49
4
66
6
6.6 dia.
E2B-S08LN02-MC-@@/E2B-S08LN04-MC-@@
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor
Dimension F (mm) Dimension G (mm)
M8
GF 8.5 dia.+0.5
0 13
15
E2B
M12 Size
Pre-wired Models (Shielded)
Short Body Pre-wired Models (Unshielded)
Long Body
Connector Models (Shielded)
Short Body Connector Models (Unshielded)
Long Body
17 Operating indicator
(yellow)
30 7.9
47
4
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M12×1
Two,clamping nuts
E2B-M12KS02-WP-@@/E2B-M12KS04-WP-@@
17 7
30 7.9
47
4
10.5 dia.
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M12×1
Two,clamping nuts
Operating indicator
(yellow)
E2B-M12KN05-WP-@@/E2B-M12KN08-WP-@@
17 Operating indicator
(yellow)
53 7.9
70
4
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M12×1
Two,clamping nuts
E2B-M12LS02-WP-@@/E2B-M12LS04-WP-@@
17 Operating indicator
(yellow)
7
53 7.9
70
4
10.5 dia.
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
M12×1
Two,clamping nuts
E2B-M12LN05-WP-@@/E2B-M12LN08-WP-@@
M12×1
M12×1 Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
31 51
4
17
E2B-M12KS02-M1-@@/E2B-M12KS04-M1-@@
M12×1
M12×1 Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
7
31 51
4
17
10.5 dia.
E2B-M12KN05-M1-@@/E2B-M12KN08-M1-@@
17
M12×1
M12×1 Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
54 74
4
E2B-M12LS02-M1-@@/E2B-M12LS04-M1-@@
17
M12×1 M12×1
Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
7
54 74
4
10.5 dia.
E2B-M12LN05-M1-@@/E2B-M12LN08-M1-@@
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor
Dimension F (mm) Dimension G (mm)
M12
GF 12.5 dia.+0.5
0 17
E2B
16
M18 Size
Pre-wired Models (Shielded)
Short Body Pre-wired Models (Unshielded)
Long Body
Connector Models (Shielded)
Short Body Connector Models (Unshielded)
Long Body
24
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Operating indicator
(yellow)
36 5.6
56
4
M18×1
Two,clamping nuts
E2B-M18KS05-WP-@@/E2B-M18KS08-WP-@@
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
24 Operating indicator
(yellow)
10
36 5.6
56
4
16.4 dia.
M18×1
Two,clamping nuts
E2B-M18KN10-WP-@@/E2B-M18KN16-WP-@@
24
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Operating indicator
(yellow)
585.6
78
4
M18×1
Two,clamping nuts
E2B-M18LS05-WP-@@/E2B-M18LS08-WP-@@
24
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
Operating indicator
(yellow)
10
585.6
78
4
16.4 dia.
M18×1
Two,clamping nuts
E2B-M18LN10-WP-@@/E2B-M18LN16-WP-@@
24
M12×1
M18×1 Two,clamping nuts
10
39 59
4Operating indicator
(yellow LED 4×90°)
E2B-M18KS05-M1-@@/E2B-M18KS08-M1-@@
M12×1
M18×1 Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
10
39 59
4
24
16.4 dia.
E2B-M18KN10-M1-@@/E2B-M18KN16-M1-@@
24
M12×1
M18×1 Two,clamping nuts
61 81
4Operating indicator
(yellow LED 4×90°)
E2B-M18LS05-M1-@@/E2B-M18LS08-M1-@@
24
M12×1
M18×1 Two,clamping nuts
10
61 81
4Operating indicator
(yellow LED 4×90°)
16.4 dia.
E2B-M18LN10-M1-@@/E2B-M18LN16-M1-@@
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor
Dimension F (mm) Dimension G (mm)
M18
GF 18.5 dia.+0.5
0 24
17
E2B
M30 Size
Pre-wired Models (Shielded)
Short Body Pre-wired Models (Unshielded)
Long Body
Connector Models (Shielded)
Short Body Connector Models (Unshielded)
Long Body
36
M30×1.5
Two,clamping nuts
Operating indicator
(yellow)
41 60
5
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
6.1
E2B-M30KS10-WP-@@/E2B-M30KS15-WP-@@
M30×1.5
Two,clamping nuts
Operating indicator
(yellow)
15
41 60
5
36
4-dia. vinyl-insulated round cable
with 3 conductors (conductor cross section :
0.141 mm² ; insulator diameter : 0.85 mm) ;
standard length : 2 m
6.1
27.8 dia.
E2B-M30KN20-WP-@@
36
M30×1.5
Two,clamping nuts
4-dia. vinyl-insulated round cable with 3 conductors
(conductor cross section : 0.141 mm² ;
insulator diameter : 0.85 mm) ; standard length : 2 m
63 82
5
6.1
Operating indicator
(yellow)
E2B-M30LS10-WP-@@/E2B-M30LS15-WP-@@
36
M30×1.5
Two,clamping nuts
Operating indicator
(yellow)
15
63 82
5
4-dia. vinyl-insulated round cable
with 3 conductors (conductor cross section :
0.141 mm² ; insulator diameter : 0.85 mm) ;
standard length : 2 m
6.1
27.8 dia.
E2B-M30LN20-WP-@@/E2B-M30LN30-WP-@@
M12×1
M30×1.5 Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
44 64
5
36
E2B-M30KS10-M1-@@/E2B-M30KS15-M1-@@
M12×1
M30×1.5 Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
15
44 64
5
36
27.8 dia.
E2B-M30KN20-M1-@@
M12×1
M30×1.5 Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
36 66 86
5
E2B-M30LS10-M1-@@/E2B-M30LS15-M1-@@
M12×1
M30×1.5 Two,clamping nuts
Operating indicator
(yellow LED 4×90°)
36 15
66 86
5
27.8 dia.
E2B-M30LN20-M1-@@/E2B-M30LN30-M1-@@
Mounting Hole Cutout Dimensions
External diameter
of Proximity Sensor
Dimension F (mm) Dimension G (mm)
M30
GF 30.5 dia.+0.5
0 36
E2B
18
Accessories (Order Separately)
Sensor I/O Connectors
M8 Connector (3 pin)
PVC Type (Unit: mm)
PVC Robot Type
Pin arrangement
1-Brown
3-Blue
4-Black
13
4
9 dia.
50
30 5
31.9 L (Cable length)
21.5
5 dia.
M8×1
Straight
XS3F-B8PVC3S2M (L = 2 m)
XS3F-B8PVC3S5M (L = 5 m)
1
3
4
9 dia.
21
50
30 5
23.1 L (Cable length)
M8×1
5 dia.
Right-angle
XS3F-B8PVC3A2M (L = 2 m)
XS3F-B8PVC3A5M (L = 5 m)
4 dia.
4
31
M8×1
9 dia.
31.421.5
L (Cable length) 30 50 5
Straight
XS3F-M321-302-R (L = 2 m)
XS3F-M321-305-R (L = 5 m)
Right-angle
XS3F-M322-302-R (L = 2 m)
XS3F-M322-305-R (L = 5 m)
4
3
1
L (Cable length) 50
20.5
9 dia.
23.1
M8×1
30 5
4 dia.
31
4
19
E2B
Sensor I/O Connectors
M12 Connector (4 pin)
PVC Type
PVC Robot Type
Pin arrangement
1-Brown
2-White
3-Blue
4-Black
Straight
XS2F-B12PVC4S2M (L = 2 m)
XS2F-B12PVC4S5M (L = 5 m)
14.9 dia.
50
30 5
40.7 L (Cable length)
1
3
2
4
5 dia.
M12×1
Right-angle
XS2F-B12PVC4A2M (L = 2 m)
XS2F-B12PVC4A5M (L = 5 m)
14.9 dia.
28.3
50
30
32.1 L (Cable length)
1
3
2 4
5
5 dia.
M12×1
Straight
XS2F-D421-D80-F (L = 2 m)
XS2F-D421-G80-F (L = 5 m)
6 dia.
40.7
14.9 dia.
L (Cable length) 50
30 5
M12×1
1
3
2
4
Right-angle
XS2F-D422-D80-F (L = 2 m)
XS2F-D422-G80-F (L = 5 m)
50
30 5
1
3
24
25.3
28.3
L (Cable length)
6 dia.
M12×1
2
143
E2B
20
Precautions
This product is not designed or rated for ensuring
safety of persons. Do not use it for such purpose.
Never use this product with an AC power supply.
Otherwise, explosion may result.
Safety Precautions
Load Short-circuit
Do not short-circuit the load, or the E2B may be damaged.
The E2B’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.
Wiring
Be sure to wire the E2B and load correctly, otherwise it may be
damaged.
Connection with No Load
Be sure to insert loads when wiring. Make sure to connect a proper
load to the E2B in operation, otherwise it may damage internal
elements.
Do not expose the product to flammable or explosive
gases.
Do not disassemble, repair, or modify the product.
Correct Use
Designing
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power is
supplied. If power supplies are connected to the Proximity Sensor and
load respectively, be sure to supply power to the Proximity Sensor
before supplying power to the load.
Effects of Surrounding Metal
When mounting the proximity sensor within a metal panel, ensure that
the clearances given in the Table1 are maintained. Failure to maintain
these distance may cause deterioration in the performance of the
sensor.
Table 1
Single Sensing Distance Type
<Shielded>
(Unit: mm)
<Unshielded>
(Unit: mm)
Double Sensing Distance Type
<Shielded>
(Unit: mm)
<Unshielded>
(Unit: mm)
WARNING
Size
Item M8M12 M18M30
l0000
d8121830
D0000
m4.5 8 20 40
n12 18 27 45
l
mn
mDd dia.
l
Size
Item M8M12 M18M30
l6152230
d24 40 55 90
D6152230
m8204070
n24 36 54 90
l
mn
mDd dia.
l
Size
Item M8M12 M18M30
l02.43.6 6
d8182745
D02.43.6 6
m4.5122445
n12 18 27 45
l
mn
mDd dia.
l
Size
Item M8M12 M18M30
l12 15 25 45
d24 40 70 140
D12 15 25 45
m8204890
n24 40 70 140
l
mn
mDd dia.
l
21
E2B
Power OFF
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore,it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power supply
has an insulated transformer. Do not use a DC power supply with an
auto-transformer.
Mutual Interference
When installing two or more proximity sensors face to face or side by
side, ensure that the minimum distances given in the Table2 are
maintained.
Table 2 Unit: (mm)
Wiring
High-tension Lines
Wiring through Metal Conduit:
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal conduit to
prevent against Proximity Sensor damage or malfunctioning.
Cable Extension
Standard cable length is less than 200 m.
The tractive force is 50 N.
Mounting
Do not tighten the sensor mounting nuts with excessive force.
Maintenance and Inspection
Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
1. Check for mounting position, dislocation, looseness, or distor tion
of the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts, and
line breakage.
3. Check for attachment or accumulation of metal powder or dust.
4. Check for abnormal temperature conditions and other environ-
mental conditions.
5. Check for proper lighting of indicators (for models with a set indi-
cator.)
Never disassemble or repair the Sensor.
Environment
Water Resistivity
The Proximity Sensors are tested intensively on water resistance, but
in order to ensure maximum performance and life expectancy avoid
immersion in water and provide protection from rain or snow.
Operating Environment
Ensure storage and operation of the Proximity Sensor within the given
specifications.
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor, in which case connect the load to the
Proximity Sensor through a relay.
<SUITABILITY FOR USE>
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the
customer’s application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used.
<CHANGE IN SPECIFICATIONS>
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON
representative at any time to confirm actual specifications of purchased product.
Size M8M12 M18M30
Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Model
E2B-( )
S08
@
S01 S08
@
S02 S08
@
N02 S08
@
N04 M12
@
S02 M12
@
S04 M12
@
N05 M12
@
N08 M18
@
S05 M18
@
S08 M18
@
N10 M18
@
N16 M30
@
S10 M30
@
S15 M30
@
N20 M30
@
N30
A20 20 80 80 30 30 120 120 50 60 200 200 100 110 300 350
B15 15 60 60 20 20 100 100 35 35 110 120 70 90 200 300
(Shielded) (Unshielded)
Table 3
Size Torque
M8 7 N·m
M12 12 N·m
M18 30 N·m
M30 50 N·m
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive w arranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR
PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY ME ET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OT HER WARRANTIES, EXPRESS OR IMPLIED .
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY
CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS
CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE,
OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND
SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PR OTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs f or OM R ON's safety rated
products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the
product.
At the customer’s request, OMR ON will provide applicab le third party certification documents identifying ratings and limitations of use that apply to the products. This inf ormation by
itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exha ustive list of all possible uses of the products, nor is
it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations
subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE H AS
BEEN DESIGNED TO ADDRESS THE RISKS , AND THAT THE OMRON PR ODUCT IS PR OPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in deter mining suitability and does not constitute a warranty. It may represent the result of OMRON’s
test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are change d, or when significant construction changes are made. However, some specifications of
the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request.
Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading
errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof .
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner ,
for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. D116-E1-01 Printed in Japan
0413
© OMRON Corporation 2013 All Rights Reserved.
OMRON Corporation Industrial Automation Company
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandr a Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
CSM_1_1_0413