Limited Internal Ericsson Internal PRODUCT TABLE OF CONTENTS SPECIFICATION E Prepared (also subject responsible if other) SEC/S Kevin Chen Approved PKJ 4000 RFPA products SEC/D Linda Julia series You 1 (1) (3) No. Checked 1/1301-BMR630/7 00152-EN/LZT146 Uen 367 Technical Specification Date 2007-9-25 2008-3-18 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Rev Reference EN/LZT 146 367 R2A March 2008 B D (c) Ericsson Power Modules AB Key Features * Industry standard Half-brick 61.00 x 57.90 x 12.70 mm (2.40 x 2.28 x 0.50 in.) * High efficiency, typ. 91.5 % at 30.2Vout half load * 1500 Vdc input to output isolation * Meets isolation requirements equivalent to basic insulation according to IEC/EN/UL 60950 * 3 million hours predicted MTBF General Characteristics * * * * * * * * * Output over-voltage protection Input under-voltage shutdown Over temperature protection Output short-circuit protection Remote sense Remote control Output voltage adjust function Highly automated manufacturing ensures quality ISO 9001/14001 certified supplier Safety Approvals Design for Environment Meets requirements in hightemperature lead-free soldering processes. Contents General Information Safety Specification Absolute Maximum Ratings ............................................................. 2 ............................................................. 3 ............................................................. 4 Product Program 28.2V,11A / 310W Electrical Specification 28.2V/12.4A / 350W Electrical Specification 30.2V/8.3A / 250W Electrical Specification 28.2V/8.3A /230W Electrical Specification Ordering No. PKJ 4316 PI ......................................... 5 PKJ 4316 API ...................................... 8 PKJ 4216N PI .................................... 11 PKJ 4216 PI........................................ 14 EMC Specification Operating Information Thermal Consideration Connections Mechanical Information Soldering Information Delivery Information Product Qualification Specification ........................................................... 17 ........................................................... 18 ........................................................... 19 ........................................................... 20 ........................................................... 21 ........................................................... 22 ........................................................... 22 ........................................................... 23 Ericsson Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 2 (3) No. SEC/S Kevin Chen Approved PKJ 4000 SEC/D Lindaseries RFPA products Checked 1/1301-BMR630/7 Uen Technical Specification Date 2007-9-25 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Rev 2 Reference EN/LZT 146 367 R2A March 2008 B (c) Ericsson Power Modules AB General Information Compatibility with RoHS requirements Ordering Information See Contents for individual product ordering numbers. Option Positive Remote Control Logic Non-threaded standoff Lead length 3.69 mm(0.145 in) Suffix P M LA Ordering No. PKJ 4316 PIP PKJ 4316 PIM PKJ 4316 PILA Note: As an example a positive logic, non-threaded standoff, short pin product would be PKJ 4316 PIPMLA. Reliability The Mean Time Between Failure (MTBF) is calculated at full output power and an operating ambient temperature (TA) of +40C, which is a typical condition in Information and Communication Technology (ICT) equipment. Different methods could be used to calculate the predicted MTBF and failure rate which may give different results. Ericsson Power Modules currently uses Telcordia SR332. Predicted MTBF for the series is: 3 million hours according to Telcordia SR332, issue 1, Black box technique. Telcordia SR332 is a commonly used standard method intended for reliability calculations in ICT equipment. The parts count procedure used in this method was originally modelled on the methods from MIL-HDBK-217F, Reliability Predictions of Electronic Equipment. It assumes that no reliability data is available on the actual units and devices for which the predictions are to be made, i.e. all predictions are based on generic reliability parameters. The products are compatible with the relevant clauses and requirements of the RoHS directive 2002/95/EC and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Exemptions in the RoHS directive utilized in Ericsson Power Modules products include: Lead in high melting temperature type solder (used to solder the die in semiconductor packages) Lead in glass of electronics components and in electronic ceramic parts (e.g. fill material in chip resistors) Lead as an alloying element in copper alloy containing up to 4% lead by weight (used in connection pins made of Brass) Quality Statement The products are designed and manufactured in an industrial environment where quality systems and methods like ISO 9000, 6 (sigma), and SPC are intensively in use to boost the continuous improvements strategy. Infant mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. Conservative design rules, design reviews and product qualifications, plus the high competence of an engaged work force, contribute to the high quality of our products. Warranty Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Limitation of Liability Ericsson Power Modules does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person's health or life). Ericsson Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) SEC/S Kevin Chen Approved PKJ 4000 SEC/D Lindaseries RFPA products 3 (3) No. Checked 1/1301-BMR630/7 Uen Technical Specification Date Rev 2007-9-25 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W 3 Reference EN/LZT 146 367 R2A March 2008 B (c) Ericsson Power Modules AB Safety Specification General information Ericsson Power Modules DC/DC converters and DC/DC regulators are designed in accordance with safety standards IEC/EN/UL60950, Safety of Information Technology Equipment. IEC/EN/UL60950 contains requirements to prevent injury or damage due to the following hazards: * * * * * * Electrical shock Energy hazards Fire Mechanical and heat hazards Radiation hazards Chemical hazards On-board DC-DC converters are defined as component power supplies. As components they cannot fully comply with the provisions of any Safety requirements without "Conditions of Acceptability". It is the responsibility of the installer to ensure that the final product housing these components complies with the requirements of all applicable Safety standards and Directives for the final product. Component power supplies for general use should comply with the requirements in IEC60950, EN60950 and UL60950 "Safety of information technology equipment". There are other more product related standards, e.g. IEEE802.3af "Ethernet LAN/MAN Data terminal equipment power", and ETS300132-2 "Power supply interface at the input to telecommunications equipment; part 2: DC", but all of these standards are based on IEC/EN/UL60950 with regards to safety. Ericsson Power Modules DC/DC converters and DC/DC regulators are UL60950 recognized and certified in accordance with EN60950. The flammability rating for all construction parts of the products meets requirements for V-0 class material according to IEC 60695-11-10. The products should be installed in the end-use equipment, in accordance with the requirements of the ultimate application. Normally the output of the DC/DC converter is considered as SELV (Safety Extra Low Voltage) and the input source must be isolated by minimum Double or Reinforced Insulation from the primary circuit (AC mains) in accordance with IEC/EN/UL60950. Isolated DC/DC converters It is recommended that a slow blow fuse with a rating twice the maximum input current per selected product be used at the input of each DC/DC converter. If an input filter is used in the circuit the fuse should be placed in front of the input filter. In the rare event of a component problem in the input filter or in the DC/DC converter that imposes a short circuit on the input source, this fuse will provide the following functions: * * Isolate the faulty DC/DC converter from the input power source so as not to affect the operation of other parts of the system. Protect the distribution wiring from excessive current and power loss thus preventing hazardous overheating. The galvanic isolation is verified in an electric strength test. The test voltage (Viso) between input and output is 1500 Vdc or 2250 Vdc for 60 seconds (refer to product specification). Leakage current is less than 1 A at nominal input voltage. 24 V DC systems The input voltage to the DC/DC converter is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. 48 and 60 V DC systems If the input voltage to Ericsson Power Modules DC/DC converter is 75 Vdc or less, then the output remains SELV (Safety Extra Low Voltage) under normal and abnormal operating conditions. Single fault testing in the input power supply circuit should be performed with the DC/DC converter connected to demonstrate that the input voltage does not exceed 75 Vdc. If the input power source circuit is a DC power system, the source may be treated as a TNV2 circuit and testing has demonstrated compliance with SELV limits and isolation requirements equivalent to Basic Insulation in accordance with IEC/EN/UL60950. Non-isolated DC/DC regulators The input voltage to the DC/DC regulator is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 1 (5) No. EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked EZYPING 4 2/1301-BMR 630Technical 01/7 Uen Specification Date Rev 2007-10-08 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Reference EN/LZT 146 367 R2A March 2008 C (c) Ericsson Power Modules AB Absolute Maximum Ratings Characteristics min Tref Operating Temperature (see Thermal Consideration section) TS Storage temperature VI Input voltage Viso Isolation voltage (input to output test voltage) Vtr Input voltage transient (tp 100 ms) VRC Remote Control pin voltage (see Operating Information section) Vadj Adjust pin voltage (see Operating Information section) Positive logic option max Unit -40 +120 C -55 +125 C -0.5 +80 V 1500 Vdc -0.5 Negative logic option -0.5 typ 100 V 20 V 20 V 28 V Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified manner. Fundamental Circuit Diagram Primary Secondary +In +Out Control RC -Out -In Isolated Feedback Vadj +Sense -Sense Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 2 (5) No. EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked EZYPING Date Rev Reference EN/LZT 146 367 R2A March 2008 2007-10-08 C DC/DC converters, Input 35-75 V, Output 12.4 A/350 W (c) Ericsson Power Modules AB 28.2 V/11 A Electrical Specification PKJ 4316 PI Tref = -40 to +90C, VI = 35 to 75 V, unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO , unless otherwise specified under Conditions. Characteristics Conditions min typ VI Input voltage range VIoff Turn-off input voltage Decreasing input voltage 30 VIon Turn-on input voltage Increasing input voltage 32 0 35 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sinewave, 1 Vp-p 5 2/1301-BMR 630Technical 01/7 Uen Specification max V 33.5 35 V 34.5 36 V F 10 max IO , Tref = +25C Efficiency Pd Power Dissipation max IO, Tref = +25C Pli Input idling power IO= 0, VI = 53 V PRC Input standby power VI = 53 V (turned off with RC) fs Switching frequency 0 -100% of max IO VOi W dB 91.0 88.8 50 % of max IO , VI = 48 V max IO, VI = 48 V, Tref = +25C 310 40 50 % of max IO Unit 75 89 % 91.0 88.8 89 38.3 39.4 3 W W 150 mW 190 210 230 kHz Output voltage initial setting and Tref = +25C, VI = 53 V, IO = 12.4 A accuracy 27.93 28.2 28.47 V Output adjust range See operation information 25.38 31.02 V Output voltage tolerance band 10-100% of max IO 27.85 28.55 V Idling voltage IO = 0 27.92 28.48 V Line regulation max IO 80 mV Load regulation VI = 53 V, 1-100% of max IO 80 mV Vtr Load transient voltage deviation VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 0.2 A/s, ttr Load transient recovery time VO tr ts Ramp-up time (from 10-90 % of VOi) Start-up time IO Output current Ilim Current limit threshold Tref < max Tref Isc Short circuit current Tref = 25C Output ripple & noise OVP Over Voltage Protection mV 40 s 8 ms 12 ms 10-100% of max IO (from VI connection to 90% of VOi) VOac 1000 See ripple & noise section, max IO, VOi Tref = +25C, VI = 53 V, IO = 0-100% of max IO 0 11 A 11.8 16 A 18 A 250 mVp-p 39.5 V 70 34.7 Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 3 (5) No. EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products 6 2/1301-BMR 630Technical 01/7 Uen Specification Checked Date EZYPING Rev Reference EN/LZT 146 367 R2A March 2008 2007-10-08 C DC/DC converters, Input 35-75 V, Output 12.4 A/350 W (c) Ericsson Power Modules AB 28.2 V/11 A Typical Characteristics PKJ 4316 PI Efficiency Power Dissipation [%] [W] 50 95 36 V 36 V 48 V 40 48 V 90 53 V 53 V 85 30 75 V 80 75 V 20 75 10 70 0 2 4 6 8 10 0 12 [A] 0 2 4 6 8 10 12 [A] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [A] 12 [C/W] 4 3.0 m/s 2.5 m/s 9 3 2.0 m/s 6 1.5 m/s 1.0 m/s 3 2 1 Nat. Conv. 0 0 0 20 40 60 80 0.0 100 [C] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. 0.5 1.0 1.5 2.0 2.5 3.0[m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Output Characteristics Current Limit Characteristics [V] [V] 28.50 30.00 36 V 36 V 28.40 48 V 53 V 28.30 75 V 48 V 24.00 53 V 18.00 28.20 12.00 28.10 6.00 75 V 0.00 28.00 0 2 4 6 8 10 Output voltage vs. load current at Tref = +25C 12 [A] 6 8 10 12 14 16 [A] Output voltage vs. load current at IO > max IO , Tref = +25C Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked EZYPING 2/1301-BMR 630Technical 01/7 Uen Specification Date 2007-10-08 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Rev Start-up EN/LZT 146 367 R2A March 2008 C (c) Ericsson Power Modules AB Top trace: output voltage (10 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: (10 ms/div.). Output Ripple & Noise Output voltage ripple at: Tref = +25C, VI = 53 V, IO = 11 A resistive load. Shut-down enabled by disconnecting VI at: Tref = +25C, VI = 53 V, IO = 11 A resistive load. Top trace: output voltage (10 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: (2 ms/div.). Output Load Transient Response Trace: output voltage (20 mV/div.). Time scale: (2 s/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: (100 + % ) 100 + 2x % R adj = 10Vo - k 2.5x % % ) Output Voltage Adjust Downwards, Decrease: 100 R adj = 10 - 2 k % Example: Increase 4% =>Vout = 29.33 Vdc (100 + 4) - 100 + 2x 4 k = 2663 k 10 28.2 2.5x 4 4 ( ) PKJ 4316 PI Shut-down Start-up enabled by connecting VI at: Tref = +25C, VI = 53 V, IO = 11 A resistive load. Example: Decrease 2% =>Vout = 27.64 Vdc 100 10 - 2 k=480 k 2 7 Reference 28.2 V/11 A Typical Characteristics ( 4 (5) No. Output voltage response to load current step- Top trace: output voltage (500 mV/div.). change (2.75-8.25-2.75 A) at: Bottom trace: load current (10 A/div.). Tref =+25C, VI = 53 V. Time scale: (0.1 ms/div.). Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 2 (5) No. EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked EZYPING Date Rev Reference EN/LZT 146 367 R2A March 2008 2007-10-08 C DC/DC converters, Input 35-75 V, Output 12.4 A/350 W (c) Ericsson Power Modules AB 28.2 V/12.4 A Electrical Specification PKJ 4316 API Tref = -40 to +90C, VI = 35 to 75 V, unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO , unless otherwise specified under Conditions. Characteristics Conditions min typ VI Input voltage range VIoff Turn-off input voltage Decreasing input voltage 31 VIon Turn-on input voltage Increasing input voltage 32.5 35 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sinewave, 1 Vp-p 8 2/1301-BMR 630Technical 03/7 Uen Specification max V 32.2 33 V 34 35 V F 10 0 max IO Efficiency Pd Power Dissipation max IO, Tref = +25C Pli Input idling power IO= 0, VI = 53 V PRC Input standby power VI = 53 V (turned off with RC) fs Switching frequency 0 -100% of max IO VOi W dB 91.0 88 50 % of max IO , VI = 48 V max IO, VI = 48 V 350 40 50 % of max IO Unit 75 89 % 91.0 88 89 41.0 44.1 3 W W 150 mW 190 210 230 kHz Output voltage initial setting and Tref = +25C, VI = 53 V, IO = 12.4 A accuracy 27.93 28.2 28.47 V Output adjust range See operation information 25.38 31.02 V Output voltage tolerance band 10-100% of max IO 27.85 28.55 V Idling voltage IO = 0 27.92 28.48 V Line regulation max IO 80 mV Load regulation VI = 53 V, 0-100% of max IO 80 mV Vtr Load transient voltage deviation VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 0.2 A/s, ttr Load transient recovery time VO tr ts Ramp-up time (from 10-90 % of VOi) Start-up time IO Output current Ilim Current limit threshold Tref < max Tref Isc Short circuit current Tref = 25C, see Note 1 Output ripple & noise OVP Over Voltage Protection Note 1: VO =<0.5 V mV 40 s 10 ms 13 ms 10-100% of max IO (from VI connection to 90% of VOi) VOac 1000 See ripple & noise section, max IO, VOi Tref = +25C, VI = 53 V, IO = 0-100% of max IO 0 12.4 A 13 19.5 A 20.5 A 250 mVp-p 39.5 V 70 34.7 Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 3 (5) No. EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products 9 2/1301-BMR 630Technical 03/7 Uen Specification Checked Date EZYPING Rev Reference EN/LZT 146 367 R2A March 2008 2007-10-08 C DC/DC converters, Input 35-75 V, Output 12.4 A/350 W (c) Ericsson Power Modules AB 28.2 V/12.4 A Typical Characteristics PKJ 4316 API Efficiency Power Dissipation [W] 50 [%] 95 36 V 36 V 90 48 V 53 V 85 48 V 40 53 V 30 75 V 75 V 80 20 75 10 70 0 0 3 6 9 12 15 [A] 0 3 6 9 12 15 [A] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [C/W] [A] 4 15 3.0 m/s 12 2.5 m/s 9 2.0 m/s 1.5 m/s 6 1.0 m/s 3 3 2 1 Nat. Conv. 0 0 0 20 40 60 80 0.0 100 [C] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. 0.5 1.0 1.5 2.0 2.5 3.0 [m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Output Characteristics Current Limit Characteristics [V] [V] 28.30 36 V 48 V 28.25 30.00 36 V 48 V 24.00 53 V 53 V 75 V 28.20 18.00 75 V 12.00 28.15 6.00 28.10 0.00 0 3 6 9 12 Output voltage vs. load current at Tref = +25C 15 [A] 6 8 10 12 14 16 18 [A] Output voltage vs. load current at IO > max IO , Tref = +25C Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked EZYPING 2/1301-BMR 630Technical 03/7 Uen Specification Date 2007-10-08 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Rev Start-up 10 Reference EN/LZT 146 367 R2A March 2008 C (c) Ericsson Power Modules AB 28.2 V/12.4 A Typical Characteristics PKJ 4316 API Shut-down Start-up enabled by connecting VI at: Tref = +25C, VI = 53 V, IO = 12.4 A resistive load. Top trace: output voltage (10 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (5 ms/div.). Output Ripple & Noise Output voltage ripple at: Tref = +25C, VI = 53 V, IO = 12.4 A resistive load. Shut-down enabled by disconnecting VI at: Tref = +25C, VI = 53 V, IO = 12.4 A resistive load. Top trace: output voltage (10 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (5 ms/div.). Output Load Transient Response Trace: output voltage (20 mV/div.). Time scale: (2 s/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: (100 + % ) 100 + 2x % R adj = 10Vo - k 2.5x % % Output Voltage Adjust Downwards, Decrease: 100 R adj = 10 - 2 k % ( 4 (5) No. ) Example: Increase 4% =>Vout = 29.33 Vdc (100 + 4) - 100 + 2x 4 k =2663 k 10 28.2 2.5x 4 4 Example: Decrease 2% =>Vout = 27.64 Vdc 100 -2 k=480 k 10 2 Output voltage response to load current step- Top trace: output voltage (1 V/div.). change (3.1-9.3-3.1 A) at: Bottom trace: load current (5 A/div.). Tref =+25C, VI = 53 V. Time scale: (0.1 ms/div.). Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 2 (5) No. EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked EZYPING 2/1301-BMR 630Technical 04/7 Uen Specification Date Rev EN/LZT 146 367 R2A March 2008 2007-10-08 B DC/DC converters, Input 35-75 V, Output 12.4 A/350 W (c) Ericsson Power Modules AB 30.2 V/8.3 A Electrical Specification PKJ 4216N PI Tref = -40 to +90C, VI = 35 to 75 V, unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO , unless otherwise specified under Conditions. Characteristics Conditions min typ VI Input voltage range VIoff Turn-off input voltage Decreasing input voltage 30 VIon Turn-on input voltage Increasing input voltage 32 0 35 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sinewave, 1 Vp-p max V 33.5 35 V 34.5 36 V F Efficiency Pd Power Dissipation max IO, Tref = +25C Pli Input idling power IO= 0, VI = 53 V PRC Input standby power VI = 53 V (turned off with RC) fs Switching frequency 0 -100% of max IO VOi W dB 91.5 90.5 50 % of max IO , VI = 48 V max IO, VI = 48 V 250 40 50 % of max IO Unit 75 10 max IO 11 Reference 91.0 % 91.5 90.5 91.0 24.7 26.2 3 W W 150 mW 190 210 230 kHz Output voltage initial setting and Tref = +25C, VI = 53 V, IO = 8.3 A accuracy 29.95 30.2 30.45 V Output adjust range See operation information 27.18 33.22 V Output voltage tolerance band 10-100% of max IO 29.90 30.50 V Idling voltage IO = 0 29.90 30.50 V Line regulation max IO 100 mV Load regulation VI = 53 V, 1-100% of max IO 100 mV Vtr Load transient voltage deviation VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/s, ttr Load transient recovery time VO tr ts Ramp-up time (from 10-90 % of VOi) Start-up time IO Output current Ilim Current limit threshold Tref < max Tref Isc Short circuit current Tref = 25C Output ripple & noise OVP Over Voltage Protection mV 40 s 8 ms 12 ms 10-100% of max IO (from VI connection to 90% of VOi) VOac 1000 See ripple & noise section, max IO, VOi Tref = +25C, VI = 53 V, IO = 0-100% of max IO 0 8.3 A 8.7 14.2 A 15.8 A 250 mVp-p 40 V 200 34 Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 3 (5) No. EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products 2/1301-BMR 630Technical 04/7 Uen Specification Checked Date EZYPING Rev 12 Reference EN/LZT 146 367 R2A March 2008 2007-10-08 B DC/DC converters, Input 35-75 V, Output 12.4 A/350 W (c) Ericsson Power Modules AB 30.2 V/8.3 A Typical Characteristics PKJ 4216N PI Efficiency Power Dissipation [W] 30 [%] 95 36 V 90 36 V 25 48 V 48 V 85 53 V 20 75 V 15 53 V 75 V 80 10 75 5 70 0 2 4 6 8 0 10 [A] 0 2 4 6 8 10 [A] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [A] [C/W] 10 3.0 m/s 8 2.5 m/s 6 2.0 m/s 1.5 m/s 4 3 2 4 1.0 m/s 2 1 Nat. Conv. 0 0 0 20 40 60 80 0.0 100 [C] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. 0.5 1.0 1.5 2.0 2.5 3.0[m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Output Characteristics Current Limit Characteristics [V] [V] 30.50 36 V 48 V 30.40 53 V 30.30 75 V 32.00 36 V 48 V 24.00 53 V 75 V 16.00 30.20 8.00 30.10 0.00 30.00 0 2 4 6 8 Output voltage vs. load current at Tref = +25C 10 [A] 4 6 8 10 12 14 16 [A] Output voltage vs. load current at IO > max IO , Tref = +25C Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked EZYPING 2/1301-BMR 630Technical 04/7 Uen Specification Date 2007-10-08 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Rev Start-up EN/LZT 146 367 R2A March 2008 B (c) Ericsson Power Modules AB PKJ 4216N PI Shut-down Start-up enabled by connecting VI at: Tref = +25C, VI = 53 V, IO = 8.3 A resistive load. Top trace: output voltage (10 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: (10 ms/div.). Output Ripple & Noise Output voltage ripple at: Tref = +25C, VI = 53 V, IO = 8.3 A resistive load. Shut-down enabled by disconnecting VI at: Tref = +25C, VI = 53 V, IO = 8.3 A resistive load. Top trace: output voltage (10 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: (2 ms/div.). Output Load Transient Response Trace: output voltage (50 mV/div.). Time scale: (2 s/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: (100 + % ) 100 + 2x % R adj = 10Vo - k 2.5x % % ) Output Voltage Adjust Downwards, Decrease: 100 R adj = 10 - 2 k % Example: Increase 4% =>Vout = 31.41 Vdc (100 + 4) - 100 + 2x 4 k = 2871 k 10 30.2 2.5x 4 4 ( ) 13 Reference 30.2 V/8.3 A Typical Characteristics ( 4 (5) No. Example: Decrease 2% =>Vout = 29.60 Vdc 100 10 - 2 k=480 k 2 Output voltage response to load current step- Top trace: output voltage (500 mV/div.). change (3-6-3 A) at: Bottom trace: load current (5 A/div.). Tref =+25C, VI = 53 V. Time scale: (0.1 ms/div.). Ericsson Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 2 (5) No. EGLANDY Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products 2/1301- BMR 630Technical 05/7 Uen Specification Checked Date EQUENXU 2008-3-18 Rev 14 Reference EN/LZT 146 367 R2A March 2008 A DC/DC converters, Input 35-75 V, Output 12.4 A/350 W (c) Ericsson Power Modules AB 28.2 V/8.3 A Electrical Specification PKJ 4216 PI Tref = -40 to +90C, VI = 35 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 VI max IO, unless otherwise specified under Conditions. Characteristics Conditions min VI Input voltage range VIoff Turn-off input voltage Decreasing input voltage 30 VIon Turn-on input voltage Increasing input voltage 32 Output voltage initial setting 0 CI Internal input capacitance PO Output power Efficiency V F 234 max IO, VI = 48 V 90.8 23.7 Input standby power VI = 53 V (turned off with RC) fs Switching frequency 0-100 % of max IO VOi tRC 36 91.5 PRC tf 34.5 90.8 max IO ts V 50 % of max IO, VI = 48 V IO = 0 A, VI = 53 V tr 35 max IO Power Dissipation ttr V 32.5 91.4 Input idling power Unit 75 50 % of max IO Pli Vtr max 10 Pd VO typ 35 W % 27.5 W 2 W 0.20 W 190 210 230 kHz Output voltage initial setting and Tref = +25C, VI = 53 V, IO = 8.3 A accuracy 27.92 28.20 28.48 V Output adjust range See operating information 22.56 31.02 V Output voltage tolerance band 10-100 % of max IO 27.64 28.76 V Idling voltage IO = 0 A 27.64 28.76 V Line regulation max IO 10 50 mV Load regulation VI = 53 V, 0-100 % of max IO 10 50 mV 1200 1800 mV 40 100 s 3 8 15 ms 6 12 20 ms 0.1 0.2 0.2 0.4 0.4 0.8 ms Load transient voltage deviation Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 0.2 A/s Ramp-up time (from 10-90 % of VOi) Start-up time 10-100 % of max IO (from VI connection to 90 % of VOi) VI shut-down fall time (from VI off to 10 % of VO) max IO IO = 0 A RC start-up time max IO 13 ms RC shut-down fall time max IO 0.4 ms (from RC off to 10 % of VO) IO = 0 A 0.4 s IO Output current Ilim Current limit threshold Tref < max Tref Isc Short circuit current Tref = 25C, see Note 1 VOac Output ripple & noise OVP Over voltage protection Note 1: VO =<0.5V 0 See ripple & noise section, max IO, VOi Tref = +25C, VI = 53 V, 0-100 % of max IO 9.5 35 s 8.3 A 12 16 A 13 17 A 50 250 mVp-p 37 39 V Ericsson Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 3 (5) No. EGLANDY Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products 2/1301- BMR 630Technical 05/7 Uen Specification Checked Date Rev EQUENXU 2008-3-18 15 Reference EN/LZT 146 367 R2A March 2008 A DC/DC converters, Input 35-75 V, Output 12.4 A/350 W (c) Ericsson Power Modules AB 28.2 V/8.3 A Typical Characteristics PKJ 4216 PI Efficiency Power Dissipation [%] [W] 30 95 36 V 90 48 V 85 53 V 75 V 80 36 V 25 48 V 20 53 V 75 V 15 10 75 5 70 0 0 2 4 6 8 [A] 0 2 4 6 8 [A] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [C/W] [A] 10 5 3.0 m /s 8 4 2.5 m /s 6 2.0 m /s 3 4 1.5 m /s 2 2 1.0 m /s 1 Nat. Conv. 0 0 0 20 40 60 80 100 [C] 0.0 Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. 0.5 1.0 1.5 2.0 2.5 3.0 [m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. VI = 53 V. Output Characteristics Current Limit Characteristics [V] 28.35 36 V 48 V 28.30 53 V 28.25 [V] 32.00 36 V 48 V 24.00 53 V 75 V 75 V 16.00 28.20 8.00 28.15 0.00 28.10 0 2 4 6 Output voltage vs. load current at Tref = +25C 8 [A] 4 6 8 10 12 14 16 [A] Output voltage vs. load current at IO > max IO , Tref = +25C Ericsson Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) EGLANDY Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products 2/1301- BMR 630Technical 05/7 Uen Specification Checked Date EQUENXU 2008-3-18 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Rev Start-up EN/LZT 146 367 R2A March 2008 A (c) Ericsson Power Modules AB Top trace: output voltage (10 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: (5 ms/div.). Output Ripple & Noise Output voltage ripple at: Tref = +25C, VI = 53 V, IO = 8.3 A resistive load. Shut-down enabled by disconnecting VI at: Tref = +25C, VI = 53 V, IO = 8.3 A resistive load. Top trace: output voltage (10V/div.). Bottom trace: input voltage (20 V/div.). Time scale: (0.1 ms/div.). Output Load Transient Response Trace: output voltage (20 mV/div.). Time scale: (2 s/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: (100 + % ) 100 + 2x % - R adj = 10Vo k % 2.5x % Output Voltage Adjust Downwards, Decrease: 100 R adj = 10 - 2 k % ) Example: Increase 4% =>Vout = 29.33 Vdc (100 + 4 ) - 100 + 2x 4 k = 2663 k 10 28.2 2.5x 4 4 Example: Decrease 2% =>Vout = 27.64 Vdc 100 10 - 2 k=480 k 2 ( ) PKJ 4216 PI Shut-down Start-up enabled by connecting VI at: Tref = +25C, VI = 53 V, IO = 8.3 A resistive load. 16 Reference 28.2 V/8.3 A Typical Characteristics ( 4 (5) No. Output voltage response to load current step- Top trace: output voltage (1.0 V/div.). change (2.1-6.2-2.1 A) at: Bottom trace: load current (5 A/div.). Tref =+25C, VI = 53 V. Time scale: (0.1 ms/div.). Ericsson Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 1 (5) No. EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked EZYPING 3/1301-BMR 630Technical 03/7 Uen Specification Date 2006-12-19 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Rev 17 Reference EN/LZT 146 367 R2A March 2008 B (c) Ericsson Power Modules AB EMC Specification Conducted EMI measured according to EN55022, CISPR 22 and FCC part 15J (see test set-up). See Design Note 009 for further information. The fundamental switching frequency is 210 kHz for PKJ 4316 API @ VI = 53 V, max IO. Conducted EMI Input terminal value (typ) Test set-up Layout recommendation EMI without filter External filter (class B) Required external input filter in order to meet class B in EN 55022, CISPR 22 and FCC part 15J. Filter components: C1=120pF C2,3,4 = 2 F C5 = 33 F C6,7 = 2.2 nF L1 = 1 H L2,3 = 0.809 H Common mode inductor The radiated EMI performance of the DC/DC converter will depend on the PCB layout and ground layer design. It is also important to consider the stand-off of the DC/DC converter. If a ground layer is used, it should be connected to the output of the DC/DC converter and the equipment ground or chassis. A ground layer will increase the stray capacitance in the PCB and improve the high frequency EMC performance. Output ripple and noise Output ripple and noise measured according to figure below. See Design Note 022 for detailed information. Output ripple and noise test setup EMI with filter Ericsson Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products 2 (5) No. Checked EZYPING 3/1301-BMR 630Technical 03/7 Uen Specification Date 2006-12-19 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Operating information Input Voltage The input voltage range 35 to 75Vdc meets the requirements of the European Telecom Standard ETS 300 132-2 for normal input voltage range in --48 and --60 Vdc systems, -40.5 to 57.0 V and --50.0 to -72 V respectively. At input voltages exceeding 75 V, the power loss will be higher than at normal input voltage and Tref must be limited to absolute max +120C. The absolute maximum continuous input voltage is 80 Vdc. Turn-off Input Voltage The DC/DC converters monitor the input voltage and will turn on and turn off at predetermined levels. The minimum hysteresis between turn on and turn off input voltage is 1V. Remote Control (RC) The products are fitted with a remote control function referenced to the primary negative input connection (- In), with negative and positive logic options available. The RC function allows the converter to be turned on/off by an external device like a semiconductor or mechanical switch. The RC pin has an internal pull up resistor to + In. The maximum required sink current is 1 mA. When the RC pin is left open, the voltage generated on the RC pin is 3.5 -- 6 V. The second option is "positive logic" remote control, which can be ordered by adding the suffix "P" to the end of the part number. The converter will turn on when the input voltage is applied with the RC pin open. Turn off is achieved by connecting the RC pin to the - In. To ensure safe turn off the voltage difference between RC pin and the - In pin shall be less than 1V. The converter will restart automatically when this connection is opened. See Design Note 021 for detailed information. Input and Output Impedance The impedance of both the input source and the load will interact with the impedance of the DC/DC converter. It is important that the input source has low characteristic impedance. The converters are designed for stable operation without external capacitors connected to the input or output. The performance in some applications can be enhanced by addition of external capacitance as described under External Decoupling Capacitors. If the input voltage source contains significant inductance, the addition of a 100 F capacitor across the input of the converter will ensure stable operation. The capacitor is not required when powering the DC/DC converter from an input source with an inductance below 10 H. Rev 18 Reference EN/LZT 146 367 R2A March 2008 B (c) Ericsson Power Modules AB External Decoupling Capacitors When powering loads with significant dynamic current requirements, the voltage regulation at the point of load can be improved by addition of decoupling capacitors at the load. The most effective technique is to locate low ESR ceramic and electrolytic capacitors as close to the load as possible, using several parallel capacitors to lower the effective ESR. The ceramic capacitors will handle high-frequency dynamic load changes while the electrolytic capacitors are used to handle low frequency dynamic load changes. Ceramic capacitors will also reduce any high frequency noise at the load. It is equally important to use low resistance and low inductance PCB layouts and cabling. External decoupling capacitors will become part of the control loop of the DC/DC converter and may affect the stability margins. As a "rule of thumb", 100 F/A of output current can be added without any additional analysis. The ESR of the capacitors is a very important parameter. Power Modules guarantee stable operation with a verified ESR value of >10 m across the output connections. For further information please contact your local Ericsson Power Modules representative. Output Voltage Adjust (Vadj) The DC/DC converter have an Output Voltage adjust pin (Vadj). This pin can be used to adjust the output voltage above or below Output voltage initial setting. When increasing the output voltage, the voltage at the output pins (including any remote sense offset) must be kept below the overvoltage trip point, to prevent the converter from shut down. Also note that at increased output voltages the maximum power rating of the converter remains the same, and the output current capability will decrease correspondingly. To decrease the output voltage the resistor should be connected between Vadj pin and --Sense pin. To increase the voltage the resistor should be connected between Vadj pin and +Sense pin. The resistor value of the Output voltage adjust function is according to information given under the output section. Ericsson Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products 3 (5) No. Checked EZYPING 3/1301-BMR 630Technical 03/7 Uen Specification Date Rev 19 Reference EN/LZT 146 367 R2A March 2008 2006-12-19 B DC/DC converters, Input 35-75 V, Output 12.4 A/350 W (c) Ericsson Power Modules AB Operating information continued Thermal Consideration Parallel Operation General Two converters may be paralleled for redundancy if the total power is equal or less than PO max. It is not recommended to parallel the converters without using external current sharing circuits. The converters are designed to operate in different thermal environments and sufficient cooling must be provided to ensure reliable operation. Cooling is achieved mainly by conduction, from the pins to the host board, and convection, which is dependant on the airflow across the converter. Increased airflow enhances the cooling of the converter. See Design Note 006 for detailed information. Remote Sense The DC/DC converters have remote sense that can be used to compensate for voltage drops between the output and the point of load. The sense traces should be located close to the PCB ground layer to reduce noise susceptibility. The remote sense circuitry will compensate for up to 10% voltage drop between output pins and the point of load. If the remote sense is not needed +Sense should be connected to +Out and -Sense should be connected to -Out. Over Temperature Protection (OTP) The DC/DC converter are protected from thermal overload by an internal over temperature shutdown circuit. When the baseplate temperature (center of baseplate) exceeds 140 C the converter will shut down (latching). The converter can be restarted by cycling the input voltage or using the remote control function. Over Voltage Protection (OVP) The DC/DC converters have latching output overvoltage protection. In the event of an overvoltage condition,the converter will shut down immediately. The converter can be restarted by cycling the input voltage or using the remote control function. Over Current Protection (OCP) The converters include current limiting circuitry for protection at continuous overload. The output voltage will decrease towards zero for output currents in excess of max output current (max IO). The converter will resume normal operation after removal of the overload. The load distribution should be designed for the maximum output short circuit current specified. The Output Current Derating graph found in the Output section for each model provides the available output current vs. ambient air temperature and air velocity at Vin = 53 V. The DC/DC converter is tested on a 254 x 254 mm, 35 m (1 oz), 16-layer test board mounted vertically in a wind tunnel with a cross-section of 305 x 305 mm. Proper cooling of the DC/DC converter can be verified by measuring the temperature at positions P1 and P2. The temperature at these positions should not exceed the max values provided in the table below. Note that the max value is the absolute maximum rating (non destruction) and that the electrical Output data is guaranteed up to Tref +90C. See Design Note 019 for further information. Position Device P1 PCB P2 Baseplate Designation max value 110 C Tref 120 C Ericsson Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) EQUENXU Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products 4 (5) No. Checked EZYPING 3/1301-BMR 630Technical 03/7 Uen Specification Date Rev EN/LZT 146 367 R2A March 2008 2006-12-19 B DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Thermal Consideration continued 20 Reference (c) Ericsson Power Modules AB Connections Definition of reference temperature (Tref) The reference temperature is used to monitor the temperature limits of the product. Temperatures above maximum Tref are not allowed and may cause degradation or permanent damage to the product. Tref is also used to define the temperature range for normal operating conditions. Tref is defined by the design and used to guarantee safety margins, proper operation and high reliability of the module. Ambient Temperature Calculation By using the thermal resistance the maximum allowed ambient temperature can be calculated. 1. The power loss is calculated by using the formula ((1/) - 1) x output power = power losses (Pd). = efficiency of converter. E.g 89.5 % = 0.895 Pin 1 2 RC 2. Find the thermal resistance (Rth) in the Thermal Resistance graph found in the Output section for each model. Calculate the temperature increase (T). T = Rth x Pd 3 Case 3. Max allowed ambient temperature is: Max Tref - T. E.g PKJ 4316 API at 2m/s: 1. (( 1 ) - 1) x 350 W = 52.3 W 0.87 2. 52.3 W x 1.8C/W = 94.1C 3. 120 C --94.1C = max ambient temperature is 25.9C. The actual temperature will be dependent on several factors such as the PCB size, number of layers and direction of airflow. Designation +In Function Positive input Remote control Connected to base plate 4 -In 5 -Out Negative input 6 -Sen Negative sense 7 Vadj Output voltage adjust 8 +Sen Positive sense 9 +Out Positive output Negative output E Ericsson Internal PRODUCT SPEC. MECHANICAL Prepared (also subject responsible if other) 4/1301-BMR 630/7 Uen Technical Specification EPANHON Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked Date 2007-1-4 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Mechanical Information 1 (2) No. Rev Reference EN/LZT 146 367 R2A March 2008 C (c) Ericsson Power Modules AB 21 E Ericsson Internal PRODUCT. SPEC. MECH. Prepared (also subject responsible if other) 5/1301-BMR 630Technical Uen Specification EPANHON Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked Date See 1 2007-1-4 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Soldering Information The product is intended for manual or wave soldering. When wave soldering is used, the temperature on the pins is specified to maximum 270 C for maximum 10 seconds. A maximum preheat rate of 4C/s and a temperature of max of +150C is suggested. When soldering by hand, care should be taken to avoid direct contact between the hot soldering iron tip and the pins for more than a few seconds in order to prevent overheating. A no-clean flux is recommended to avoid entrapment of cleaning fluids in cavities inside the product or between the product and the host board. The cleaning residues may affect long time reliability and isolation voltage. Delivery Package Information The products are delivered in antistatic clamshell trays. Clamshell Specifications Material Conductive/dissipative PET Surface resistance 105 < Ohm/square < 1012 Bake ability The clamshells are not bake able. Clamshell capacity 10 products/clamshell Clamshell thickness Box capacity Clamshell weight 1 (3) No. 25 mm [0.984 inch] 50 products (5 full clamshells/box) 150 g empty, typical 1050 g one full clamshell Rev Reference EN/LZT 146 367 R2A March 2008 C (c) Ericsson Power Modules AB 22 E Ericsson Internal PRODUCT. SPEC. MECH. Prepared (also subject responsible if other) 2 (3) No. 5/1301-BMR 630Technical Uen Specification EPANHON Approved PKJ 4000 SEC/D (Juliaseries You) RFPA products Checked Date See 1 2007-1-4 DC/DC converters, Input 35-75 V, Output 12.4 A/350 W Rev 23 Reference EN/LZT 146 367 R2A March 2008 C (c) Ericsson Power Modules AB Product Qualification Specification Characteristics External visual inspection IPC-A-610 Dry heat IEC 60068-2-2 Bd Temperature Duration +125 C 1000 h Cold (in operation) IEC 60068-2-1 Ad Temperature TA Duration -45C 72 h Damp heat IEC 60068-2-67 Cy Temperature Humidity Duration +85 C 85 % RH 1000 hours Operational life test MIL-STD-202G method 108A Duration 1000 h Change of temperature (Temperature cycling) IEC 60068-2-14 Na Temperature range Number of cycles Dwell/transfer time -40 to +100 C 1000 15 min/0-1 min Vibration, broad band random IEC 60068-2-64 Fh, method 1 Frequency Spectral density Duration 10 to 500 Hz 0.07 g2/Hz 10 min in each 3 perpendicular directions Mechanical shock IEC 60068-2-27 Ea Peak acceleration Duration Pulse shape Directions Number of pulses 100 g 6 ms Half sine 6 18 (3 + 3 in each perpendicular direction) Robustness of terminations IEC 60068-2-21 Test Ua1 Plated through hole mount products All leads Resistance to soldering heat IEC 60068-2-20 Tb Method 1A Solder temperature Duration 270 C 10-13 s Solderability IEC 60068-2-20 test Ta Preconditioning Temperature, SnPb Eutectic Temperature, Pb-free Steam ageing 235 C 260 C Immersion in cleaning solvents IEC 60068-2-45 XA Method 2 Water Glycol ether Isopropanol +55 C +35 C +35 C