https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Surge protective device, three channel with remote indicator contact for 240/480V split phase AC, 3-wire plus ground. Your advantages With floating remote indication contact Optical, mechanical status indication for the individual arresters Mechanical coding of all slots Multi-channel type 2 arresters Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626445045 Weight per Piece (excluding packing) 380.000 g Custom tariff number 85363030 Country of origin Germany Technical data Dimensions Height 98.7 mm Width 53.4 mm Depth 65.5 mm Horizontal pitch 3 Div. Ambient conditions 02/06/2021Page1/11 https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Technical data Ambient conditions Degree of protection IP20 (only when all terminal points are used) Ambient temperature (operation) -40 C ... 80 C Ambient temperature (storage/transport) -40 C ... 80 C Altitude 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 25g (Half-sine / 11 ms / 3x X, Y, Z) Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) General IEC test classification II T2 EN type T2 IEC power supply system TN-S TT Mode of protection L-N N-PE Mounting type DIN rail: 35 mm Color jet black RAL 9005 Housing material PA 6.6 PBT Degree of pollution 2 Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 3 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 240/480VAC (TN-S/TT) Nominal frequency fN 50 Hz (60Hz) Maximum continuous operating voltage UC (L-N) 385 VAC Maximum continuous operating voltage UC (L-PE) 385 VAC Maximum continuous voltage UC (N-PE) 305 VAC Nominal discharge current In (8/20) s 20 kA Maximum discharge current Imax (8/20) s 40 kA Follow current interrupt rating Ifi (N-PE) 100 A (305 V AC) Short-circuit current rating ISCCR 25 kA Voltage protection level Up (L-N) 2 kV Voltage protection level Up (L-PE) 2.2 kV 02/06/2021Page2/11 https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Technical data Protective circuit Voltage protection level Up (N-PE) 1.5 kV Residual voltage Ures (L-N) 2 kV (at In) 1.7 kV (at 10 kA) 1.5 kV (at 5 kA) 1.3 kV (at 3kA) Residual voltage Ures (L-PE) 2.2 kV (at In) 1.7 kV (at 10 kA) 1.5 kV (at 5 kA) 1.4 kV (at 3kA) Residual voltage Ures (N-PE) 0.4 kV (at In) 0.25 kV (at 10 kA) 0.15 kV (at 5 kA) 0.1 kV (at 3kA) TOV behavior at UT (L-N) 415 VAC (5s / withstand mode) 440 VAC (120min / withstand mode) TOV behavior at UT (N-PE) 1200 VAC (200ms / withstand mode) Response time tA (L-N) 25 ns Response time tA (L-PE) 100 ns Response time tA (N-PE) 100 ns Max. backup fuse with branch wiring 125 A (gG) Indicator/remote signaling Switching function Changeover contact Operating voltage 5 VAC ... 250 VAC 30 VDC Operating current 5 mA AC ... 750 mA AC 1 ADC Connection method Plug-in/screw connection via COMBICON Screw thread M2 Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section flexible 0.14 mm ... 1.5 mm Conductor cross section solid 0.14 mm ... 1.5 mm Conductor cross section AWG 28 ... 16 Connection data Connection method Screw connection Screw thread M5 02/06/2021Page3/11 https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Technical data Connection data Tightening torque 3 Nm (1.5mm ... 16mm) 4.5 Nm (25mm...35mm) Stripping length 16 mm Conductor cross section flexible 1.5 mm ... 25 mm Conductor cross section solid 1.5 mm ... 35 mm Conductor cross section AWG 15 ... 2 Connection method Fork-type cable lug Conductor cross section flexible 1.5 mm ... 16 mm UL specifications SPD Type 1 Maximum continuous operating voltage MCOV (L-L) 750 VAC Maximum continuous operating voltage MCOV (L-N) 385 VAC Maximum continuous operating voltage MCOV (L-G) 385 VAC Maximum continuous operating voltage MCOV (N-G) 305 VAC Nom. voltage 240/480VAC (Split phase) Mode of protection L-L L-N L-G N-G Power distribution system Split phase Nominal frequency 50/60 Hz Voltage protection rating VPR (L-L) 2500 V Voltage protection rating VPR (L-N) 1500 V Voltage protection rating VPR (L-G) 2000 V Voltage protection rating VPR (N-G) 1200 V Nominal discharge current In 20 kA Maximum Surge Current per Phase 40 kA Short-circuit current rating (SCCR) 200 kA UL indicator/remote signaling Operating voltage 125 VAC Operating current 1 A AC Tightening torque 2 lbf-in. ... 4 lbf-in. Conductor cross section AWG 30 ... 14 UL connection data Conductor cross section AWG 10 ... 2 Tightening torque 30 lbf-in. 02/06/2021Page4/11 https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Technical data Standards and Regulations Standards/regulations IEC61643-11 2011 EN61643-11 2012 Environmental Product Compliance REACh SVHC Lead 7439-92-1 Drawings Dimensional drawing Circuit diagram 12 98,7 65,7 53,4 44 89,8 14 11 FM L1 L2 N Classifications eCl@ss eCl@ss 10.0.1 27130805 eCl@ss 11.0 27130805 eCl@ss 6.0 27130800 eCl@ss 7.0 27130805 eCl@ss 8.0 27130805 eCl@ss 9.0 27130805 ETIM ETIM 5.0 EC000941 ETIM 6.0 EC000941 ETIM 7.0 EC000941 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed 02/06/2021Page5/11 https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Approvals Ex Approvals Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 cULus Listed Accessories Accessories Bridge Wiring bridge-MPB F600X16/ 1GS-2818355 Wiring bridge flexible, diameter: 16 mm, with a fork-type cable lug on one side, length: 600 mm Wiring bridge-MPB F600X16/ 1GS-2818355 Wiring bridge flexible, diameter: 16 mm, with a fork-type cable lug on one side, length: 600 mm 02/06/2021Page6/11 https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Accessories Wiring bridge-MPB F200X16/ 1GS-2818339 Wiring bridge flexible, diameter 16 mm, with a fork-type cable lug on one side, length: 200 mm Wiring bridge-MPB 18/1-10/1.0.0-2830443 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 10 pitches with contact sequence 1-0-0 Wiring bridge-MPB 18/4-12-2809296 Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 12-pos. Wiring bridge-MPB 18/4- 8-2809283 Wiring bridge for modules with connecting pitch 17.5 mm, 4-phase, 8-pos. Wiring bridge-MPB 18/3- 6-2809241 Wiring bridge for modules with connecting pitch 17.5 mm, 3-phase, 6-pos. 02/06/2021Page7/11 https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Accessories Wiring bridge-MPB 18/1-57-2809238 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 57-pos. Wiring bridge-MPB 18/1-12-2748593 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 12-pos. Wiring bridge-MPB 18/1- 9-2748580 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 9-pos. Wiring bridge-MPB 18/1- 8-2748577 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 8-pos. Wiring bridge-MPB 18/1- 6-2748564 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 6-pos. 02/06/2021Page8/11 https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Accessories Wiring bridge-MPB 18/1- 4-2809225 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 4-pos. Wiring bridge-MPB 18/1- 3-2809212 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 3-pos. Wiring bridge-MPB 18/1- 2-2809209 Wiring bridge for modules with connecting pitch 17.5 mm, 1-phase, 2-pos. Device marking Zack marker strip-ZBN 18:UNBEDRUCKT-2809128 Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Feed-through terminal block Feed-through terminal block-DK-BIC-35-2749880 Feed-through terminal block for VAL and FLT applications 02/06/2021Page9/11 https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Accessories Labeled device marker Marker for terminal blocks-ZBN 18,LGS:ERDE-2749589 Marker for terminal blocks, Strip, white, labeled, horizontal: Grounding symbol, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Marker for terminal blocks-ZBN 18,LGS:L1-N,ERDE-2749576 Marker for terminal blocks, Strip, white, labeled, horizontal: L1, L2, L3, N, GND, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5 Marker pen Marker pen-B-STIFT-1051993 Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm Spare parts Type 1 surge protection plug-VAL-US-240/40-P-2910336 UL Recognized type 1 SPD and IEC type 2 surge protection plug with a varistor and thermal disconnect for use with VALUS base elements, mechanical and visual fault warning 02/06/2021Page10/11 https://www.phoenixcontact.com/us/products/2910365 Type 1 surge protection device-VAL-US-240/40/2+1-FM-2910365 Accessories Type 1 surge protection plug-GDT-US-NG/40-P-2910342 UL Recognized type 1 SPD and IEC type 2 surge protection plug with a gas discharge tube and thermal disconnect for use with VAL-US base elements, mechanical and visual fault warning Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 02/06/2021Page11/11