Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Rotary Switches
Single Deck Rotary Switches
DIMENSIONS in inches [and millimeters]
SERIES 77
0.5" Diameter, 200 mA
0.18" Behind Panel
FEATURES
Small Size - Minimal Space Required
Behind Panel
Available with Continuous Rotation
or a Fixed Stop
High Stop Strength
Shaft and Panel Seal
Process Seal available
Single Deck with 1 or 2 Poles
APPLICATIONS
• Handheld Radios
Handheld Medical Devices
• Night Vision Products
Laser Aiming Devices
Series
77
Series
75
Series
50
Ø
.500
12,7[ ]
Ø
.200
±
.004
5,08
±
0,1[ ]
.625
15,88[ ]
REF
.375
9,53[ ]
.250
±
.005
6,35
±
0,12[ ]
.180
4,57[ ]
.066
±
.010
1,68
±
0,25[ ]
Ø
.125
±
.001
3,18
±
0,02[ ]
.250
±
.005
6,35
±
0,12[ ]
.109
±
.010
2,77
±
0,25[ ]
Ø
.326
8,28[ ]
18°
.340
±
.005
8,64
±
0,12[ ]
18°
10X
36°
.314
±
.008
7,98
±
0,2[ ]
Ø
CIRCLE OF TERMINAL
CENTERS
.200
±
.010
5,08
±
0,25[ ]
.094
±
.005
2,39
±
0,12[ ]
11X Ø
.015 +.003
-.002
0,38 +0,07
-0,05
[ ]
.072
±
.005
1,83
±
0,12[ ]
12X Ø
.015 +.003
-.002
0,38 +0,07
-0,05
[ ]
TERMINAL VIEW
1 POLE
TERMINAL VIEW
2 POLE
HOUSING
FLAT
SHAFT FLAT
POS.1
3/8-32 UNEF-2A
THREAD
COMMON TERMINAL
TERMINAL 1
TERMINAL 1
COMMON 1
COMMON 2
RECOMMENDED PANEL CUT-OUT
POSITI0N 1
.345 +.003
-.000
8,76 +0,07
-0,00
[ ]
Ø
.375 +.005
-.000
9,53 +0,12
-0,00
[ ]
Ø.008 [0,2]
Ø.008 [0,2]
RECOMMENDED PCB LAYOUT (VIEWED FROM SWITCH SIDE OF PCB)
TERMINAL 1
TERMINAL 1
1 POLE LAYOUT
2 POLE LAYOUT
*CUSTOMER TO ESTABLISH PCB DATUMS FOR HOLE PATTERN PLACEMENT
**
12X Ø
.024
±
.004
0,61
±
0,1[ ]
11X Ø
.024
±
.004
0,61
±
0,1[ ]
Ø
.200
5,08[ ]
Ø
.200
5,08[ ] .072
1,83[ ]
36° 36°
Grayhill part number and date code marked
on label. Customer part number marked on
request.
Recommended Mounting Torque: Tighten
mounting hex nut to 12 in-lb (15 in-lb max).
Before applying torque, rotation of the switch
housing must be constrained by the housing
flat via the "Recommended Panel Cut-Out"
or similar method. Constraining by PCB or
anything soldered to the terminals will result
in damage to the switch
Unless otherwise specified, tolerances are ± .015 inch and ± 3 degrees
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Rotary Switches
Single Deck Rotary Switches
Electrical Specifications
Contact Resistance: 50 milliohms max
(15 milliohms initially).
100 milliohms max low level.
Insulation Resistance: 50,000 Mohms initially
(10,000 Mohms after life) at 100 VDC
Voltage Breakdown: 600 Vac initially,
250 Vac after life
Mechanical / Environmental Ratings
Operating Temperature: -40°C to +85°C
Storage Temperature: -65°C to +100°C
Altitude: 70,000 feet
Rotational Torque: 3 in-oz min. to 7 in-oz
max
Stop Strength: 7.5 inch pounds min
Withstanding Shaft Push Force: 100
pounds
Weight: 4.7 grams with hardware
3.9 grams without hardware
Vibration: MIL-DTL-3786, MIL-STD-202,
method 204, condition "B"
Shock: MIL-DTL-3786, Medium impact per
MIL-STD-202, Method 213.
Moisture Resistance: MIL-DTL-3786, MIL-
STD-202, Method 106
Salt Spray: MIL-DTL-3786, MIL-STD-202,
method 101, condition "B"
Explosion Proof: MIL-DTL-3786, MIL-STD
202, method 109
Immersion: With shaft operation – Shaft and
panel seal withstands water pressure of 15
psi minimum per MIL-DTL-3786 (Equivalent to
33ft [10m] immersion for 30 minutes).
Without shaft operation - Shaft and panel
sealed to withstand 74ft [22m] immersion for 2
hours, MIL-DTL-810G Method 512.5.
Sand and Dust: MIL-DTL-3786, MIL-STD-
202 Method 110
Flux Seal (Process Sealed Versions): Level
1 & 2 per MIL-DTL-3786.
Materials and Finishes
Switch Base: Diallyl Phthalate per MIL-M-14
Bushing: Zinc alloy
Detent Rotor: Nylon
Detent Balls: Steel, nickel-plated
Contact Spring: music wire
Detent Spring: Stainless steel
Shaft: Stainless steel
Shaft Seal: Ethylene Propylene
Panel Seal: Silicone
Rotor Contact: Silver cad-oxide, gold-plated
Terminals and Common: Brass, gold plate
.00002" minimum thickness over silver plate
.0003" minimum.
Mounting Hardware: One mounting nut .089"
thick by .433" across flats and one external tooth
lockwasher supplied with each switch. Mounting
nut is brass, nickel plated and lockwasher is
stainless steel.
Additional Characteristics
Contact Type: Non-shorting or Shorting, wiping
contacts
Terminals: Switches are provided with the full
circle of terminals regardless of the number of
active positions.
Shorting Characteristics
Typical values for current interruption during
shorting:
Temperature Duration
Room Temperature to
+85° C
< 0.2 ms
Reduced Temperatures < 20 ms
Values present typical current interrupt for a single
bounce in a pulse train of unspecified length when
rotating between switch positions.
Series 77
S = Shaft & Panel Sealed, leave blank for no shaft & panel seal
P = PC Terminals
T = Process Seal*, Leave blank for no process seal
Angle of throw: 36 = 36°
Number of Decks: 01 Only
Stop arrangement: Needed only with 1 pole switches with maximum positions.
Leave blank for continuous rotation; add F for fixed stop.
Contacts: N = Non-shorting; S = Shorting*
Positions per pole: 02 up to 10 positions (1 pole),
02 up to 05 positions (2 poles)
Poles per deck: 1 or 2
77SPT36-01-1-10N-F
ORDERING INFORMATION
For prices and discounts, contact a local Sales Office, an authorized local Distributor, or Grayhill.
Contact Grayhill if the life limiting criteria is more critical than those listed, if the required cycles
of operation are greater than those listed, if a larger make and break current is required than the
one listed for the desired number of cycles, or if elevated temperatures or reduced pressures are
part of the operating environment.
RATED LOADS
Switches are rated to make and break the following loads:
One cycle is 360-degree rotation and a return through all switch positions to the starting position.
Environment
Condition
Lamp Load Inductive Load
(140mH) Resistive Load
Milliamp Volts Milliamp Volts Milliamps Volts
Atmospheric
Pressure
50 28 VDC 30 28 VDC 50 12 VDC 25,000 10,000
10 28 VDC 25,000
50 28 VDC 10,000
100 28 VDC 7,500
Reduced
Pressure
(70,000 feet)
100 28 VDC 7,500 7,500
Cycles
Shorting
Cycles
Non-shorting
200 28 VDC 5,000
50 115Vms 10,000 10,000
10 0.03VDC 25,000 10,000
10,000
10,000
7,500
5,000
*Process seal (T style) is required for all Shorting contact switches
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Grayhill:
77P36-01-1-08N 77P36-01-1-03N 77SPT36-01B03N 77SP36-01-1-04N 77SPT36-01A10N 77SPT36-01B06N
77SPT36-01C04N 77P36-01-1-07N 77SPT36-01B09N 77P36-01-1-06N 77SP36-01-1-05N 77SP36-01-1-08N
77SP36-01-1-09N 77SP36-01-1-10N 77P36-01-1-02N 77SP36-01-2-05N 77SP36-01B10N 77P36-01-1-05N
77SPT36-01B08N 77SPT36-01B10N 77P36-01-1-09N 77SP36-01-1-07N 77SPT36-01B04N 77SPT36-01B07N
77P36-01-1-04N 77P36-01-1-10N 77SP36-01-1-03N 77SP36-01-1-06N 77SPT36-01B05N 77SPT36-01C05N
77SP36-01-1-02N 77SPT36-01B02N 77SPT36-01-1-06N 77SPT36-01-1-10N-F 77SPT36-01-1-07N 77SP36-01-1-
10N-F 77SPT36-01-2-05N 77SPT36-01-1-05N 77SPT36-01-1-04N 77SPT36-01-1-02N 77SPT36-01-1-03N
77SPT36-01-1-08N 77SPT36-01-1-09N 77P36-01-2-02N 77SP36-01-2-02N 77SP36-01-2-04N 77PT36-01-1-02N
77PT36-01-2-02N 77SPT36-01-2-04N 77PT36-01-1-05S 77PT36-01-1-10S-C 77SPT36-01-1-06S 77PT36-01-1-06S
77SPT36-01-1-10N-C 77SPT36-01-1-10S-C 77SP36-01-2-03N 77PT36-01-1-03S 77SP36-01-1-10N-C 77PT36-01-
1-10N-C 77SPT36-01-1-08S 77SPT36-01-2-02N 77P36-01-1-10N-F 77SPT36-01-1-03S 77SPT36-01-1-04S
77SPT36-01-1-05S 77PT36-01-1-07S 77PT36-01-1-04S 77PT36-01-1-10S-F 77SPT36-01-1-09S 77PT36-01-1-08S
77PT36-01-1-09S 77SPT36-01-1-10S-F 77P36-01-1-10N-C 77SPT36-01-1-02S 77PT36-01-1-10N-F 77SPT36-01-2-
03N 77PT36-01-1-02S 77SPT36-01-1-07S