SSB_K001-K007_GB 24.10.2003 11:57 Uhr Seite K.2 Relay coupler Relay coupler - overview Weidmuller relay modules have a universal foot structure so that they can be fitted in rows on the TS 32, TS 35 x 7.5 and TX 35 x 15 mounting rails acc. to EN 50 035 and EN 50 022. In the coil circuit of the relay modules, an LED status indication shows the switching state of the relay. Our highlight: MICROSERIES Coupler modules in terminal format The slot-in width of 6.1 mm allows for space-saving installation of the MICROSERIES relays in a wide range of applications. The MICROSERIES is particularly suitable for the modification and extension of installations and machinery. In such cases, it helps to make optimum use of the limited space available in switchgear cabinets. Marking The tab surfaces enable equipment to be clearly marked using a WS marker. Holding and ejecting mechanism The innovative holding and eject mechanism clips the assembled module securely onto the basic terminal. With the reliable eject function, the coupler can be removed quickly and simply from the base. K Relay and optocoupler module Plug-in relay and optocoupler modules allow for individual adjustment of the module functions. Relay couplers are available with different power outputs with either AgSnO and gold contacts. K.2 Connection technology Pluggable cross-connectors Most of our relay couplers are available with screw or tension clamp connections. The ZQV 4N plug-in cross-connectors are available in various colours and with different numbers of poles. They allow for reliable and distinct cross-connections between the four input and output potentials. SSB_K001-K007_GB 24.10.2003 11:57 Uhr Seite K.3 Contact types Protective circuits for the contacts Switching small and large capacities Several contact types and combinations are available ex stock: The switching of inductive or capacitive loads produces switching sparks which can influence the electrical service life of the relays. For automation technology, the EGR EG7 relay coupler is ideal for switching extremely small capacities (up to 40 w) under ohmic load. The signals are reliably transmitted to the controllers. The switching of large capacities for energy and supply technology is achieved by the RS31 relay coupler, with a guaranteed switching capacity of 3.5 kVA under ohmic load. (EGR EG7, RS 30) 1 NOC (EGR RG7, DKR, RS 30) 1 NCC and 1 NOC The following protective circuits for the contacts reduce contact wear: (WRS) Diode 2 NOCs (WRS) 3 NOCs (WRS) 1 change-over contact (EGR/RST EG7, WRS, DKR, PRS/PRZ MCZ R, RS 30, RS 31) 2 change-over contacts (WRS, RS 32, PRS/PRZ) 4/8/16 change-over contacts (RSM) - + US Load UD 1 2 t Advantage: Can be used for all capacities, low overvoltage, minimum space required, low price Disadvantage: Very large release delay Switching times of the relay modules Typical pick-up delay < 10 ms Typical release delay < 12 ms Single contact Number of operations 1 NCC Diode and Z-diode - Relay coupler Relay coupler - overview + US Switching capacity (kVA) UZD Contact service life under ohmic load 1 2 Direct current (A) Load t Advantage: Low overvoltage (defined by Z-diode), low release delay Disadvantage: Cannot be used for large capacities Direct voltage (V) Contact material DC load-limit curve under ohmic load RC combination - + (~) (~) US R Load Reduction factor F The relay modules are suitable for universal use, with the choice of contact material the crucial criterion. The contact is used for safe transmission of control signals and also for switching power contactors. URC C 1 Advantage: Gold-plated or gold-flashed AgNi contacts are used for most applications. Hard Disadvantage: gold plated contacts with gold plating exceeding 2 m in thickness allow even extremely small capacities (up to 40 W) Varistor to be switched. AgSnO2 or AgCdO con+ - tacts are used for switching higher capac(~) (~) ities (RS 31). Load 2 t Low overvoltage, low release delay High current load on the contacts when switching on; more complicated and expensive at greater capacities Power factor (cos ) Reduction factor under inductive load cos < 1 No. of cycles eff. = No. of cycles at (cos = 1) x red. factor F US VDR UVDR 1 2 t Advantage: Low release delay, low price Disadvantage: Cannot be used for all operating voltages and capacities US 1 2 Voltage progression Closing Opening K.3 K SSB_K001-K007_GB 24.10.2003 11:57 Uhr Seite K.4 Relay coupler Relay coupler - overview Relay coupler with plugged relay Derating curve Notes on application Relay couplers with plugged relay have only limited suitability for use in a highly oscillating environment. Preference should be given to relay couplers with soldered relays. The transition resistance of the relay contacts is a key factor contributing to temperature increase inside the relay modules. This relationship is illustrated by a derating curve, defined as the function of the permissible current plotted against the ambient temperature. The key data of the triggering device must be precisely adhered to when using UC versions in DC circuits. As a result of their pre-circuitry, UC versions take up larger quantities of current. The internal current limit of standard initiators can mean that the triggered relay couplers are not switched through. The permissible current (Curve a) is determined for the following operating conditions: - Continuous operation - Rated input voltage + 10 percent Relay couplers with 24 V AC/DC input are not suitable for triggering by initiators; purely DC versions are recommended for these applications. - Several relay modules working under load, mounted horizontally in rows on mounting rail, without any spacing If the modules are mounted with a spacing > 20 mm, this results in a higher current load (Curve b). Curve b also shows the maximum values for switching or short-time operation in horizontally mounted state. RC combination Long leads are subject to greater electrical and electromechanical influences. This may cause malfunctions and even failure of the relay modules. One possible remedy is to insert an RC combination to filter out the interference. RC combinations are available for all common relay couplers, as pluggable (PLUGSERIES) solutions or WDU 12C and DKU 12C terminals. K K.4 SSB_K001-K007_GB 24.10.2003 11:57 Uhr Seite K.5 Relay coupler - overview Protective separation All equipment guaranteeing "protective separation" is to be designed so that any faults (e.g. mechanical faults) cannot affect the insulation. If a mechanical fault occurs in a relay (bent soldering post, broken winding wire or broken spring), "protective separation" must also be guaranteed in such cases. Relays are specified and tested to IEC 255 and VDE 0435. Neither standard makes reference to EN 50 178 (electronic equipment for use in high current installations), nor do they contain a definition of "protective separation". Furthermore, other measuring conditions are used as the basis for the test voltages stated for the relays. So the test voltages cannot be transferred to EN 50 178 or DIN VDE 0106 part 101. In view of the fact that users are increasingly turning to equipment which guarantees "protective separation", many relay manufacturers now refer to DIN VDE 0106 and test their products accordingly. The stated values then correspond with "protective separation". Input curcuit Rated voltage [V] Rated current [mA] Nominal consumption [W/VA] Operating voltage [V] Pull-in current [mA] Response power [W/VA] Drop-out voltage [V] Release current [mA] Output circuit Max. switching voltage [V] Switch-on current [A] Continuous current [A] Switching power [W/VA] Min. switching power [W] Service life Standards Response time [ms] The following standards are fulfilled: Release time [ms] * EN 50 178: Electronic equipment for use in high current installations * DIN VDE 01206 part 101: Protection from dangerous body currents, basic requirements for "protective separation" in electrical equipment * IEC 255, DIN VDE 0109: Insulation coordination for equipment within low-voltage systems, including clearance and creepage distances for configured printed circuit boards * DIN VDE 0435: Electrical relays, switching relays Reference voltage at which the relay coupler works Typical input voltage => 5 Vdc, 12, 24, 48, 60, 115, 230 ac/dc Quotient of input voltage and input resistance Input resistance => coil resistance + resistance of the triggering device (R; LED; GL, ...) Input voltage x input current dc/ac with tolerance +/-10% or +5/-15% typical range for relay coupler 250 mW > Pv > 1 W 0.4 VA > Pv > 1.2 VA Smallest input current needed for the relay coupler to respond (Tu = 293 K) Smallest input current at which the relay switches from idle to working position (Tu = 293 K) Product of operating voltage and pull-incurrent Voltage at which the relay reliably drops away Input current at which the relay reliably drops away Relay coupler Definition of the technical data Switching frequency [Hz] Voltage strength [kV] Protective separation Light arc Contact wear Spark extinction Reduction factor Max. voltage allowed at the relay contact Current allowed to flow for max. 4 seconds after the relay contact closes Current allowed to flow constantly after the contact closes Product of output voltage and switch-on current, under ohmic, inductive or capacitive load Smallest power to be switched via the contact No. of switching cycles until the contact fails - mechanical => without electric load - electrical => under ohmic or inductive ac/dc load Time from closing the exciter voltage until the contact closes/opens Time from opening the exciter voltage until the contact closes/opens Switching circuits/sec. in pulse duty factor 1:2 (ton = toff) Max. test voltage between input and output circuit which does not cause a discharge Relay coupler acc. to EN 50178 or VDE 0106 part 101 Flow of current on opening contacts, caused by ionisation The switching of inductivity causes extensive material migration Results: => Scratches and tip formation on contact surfaces => Failure caused by contacts interlocking Limitation of transient overvoltage by switching the inductive load: => RC combinations => Z-diodes / suppressor diodes => varistors Factor by which the service life is reduced when switching inductive loads K.5 K SSB_K001-K007_GB 24.10.2003 11:57 Uhr Seite K.6 Relay coupler - overview Relay coupler Enclosure types for relay couplers PLUGSERIES MICROSERIES WAVESERIES The modular component system represents a new generation of pluggable relay couplers. The key element is an innovative relay base designated PXS (screw clamp) or PXZ (tension clamp). Both products reflect the functionality of relays and terminals, and experience gained from their commercial use. PLUGRELAY is the ideal connection system between the relay and the application. Relay and optocoupler versions in the MICROSERIES are used in industrial automation applications for separating and coupling digital input and output signals. The compact design makes them perfectly suited for use in sub-distributors or switch cabinets. With its compact shape, MICROSERIES combines the functions of the classical coupling level with the terminal level. * Slot-in width 6.1 mm Innovative electronic components require an enclosure or housing which reflects their specific functions. It must allow for adjusting and control functions and support technical requirements, such as heat dissipation or electromagnetic compatibility. A compact design saves space in the switch cabinet and reduces assembly costs. Ergonomic design is increasingly important for top quality relay coupler interfaces. * Pluggable cross-connection for four input and output potentials The WAVEBOX fulfils all these criteria, with outstanding features including: * Tried and tested ZQV 4N cross-connection system * * * * * * Modular principle The new PLUGSERIES is extremely easy to handle. Commercially available relays are simply plugged in, retaining clips provide a firm hold, and LED displays with a freewheel diode can be plugged in. * Relays simply plugged in: suitable for miniature circuit of both standard and RT designs K * Independent connection technology: screw connection or tension spring technology, nominal cross-sectional area 0.5 ... 2.5 mm2 * Robust design of the retaining clip * One or two change-over contacts; max. switching current 16 A * Minimum wiring workload thanks to ZQV 2.5N pluggable cross-connectors * Modular system makes for easy handling: - Relay base, LED display, retaining hook and relay - Clips on to TS 35 - Marking with WS tabs on retaining hook * Pluggable LED with freewheel diode. K.6 * Wide range of input voltage from 5 .. 230 V * LED status display, reverse polarity protection diode, recovery diode * Enclosure material WEMID (combustibility V0 acc. to UL 94) * Innovative holding and ejecting mechanism * Marking surface to take standard marking WS 12/6 CE marking Weidmuller's relay couplers carry the CE mark and comply with the requirements laid down by EN 50 081 part 1 and EN 50 082 part 2. They can be used in both in a wide range of applications and industries Suitable ESD measures must be taken during installation. Overvoltage protection must be provided for long leads as protection from lightning. Assembly without tools Pluggable circuit board ZQV 2.5V pluggable cross-connector Hinged transparent cover Marking with WS tabs Clips onto TS 35 Connection systems The user can choose between BLZ screw plug-in connectors and BLZF tension clamp plug-in systems, up to 2.5 mm2 and finely stranded, for the greatest possible flexibility when wiring up the circuits. Printed circuit board If the lateral locking hook is squeezed on the head end, it can be pulled out of the enclosure together with the connection level and the circuit board. The circuit board can only be pulled out without current voltage. Cross-connector The ZQV 2.5 N/2 cross-connectors can be used to connect rows of Wavebox housings in the lower part of the enclosure. The cross-connector can take up to 8 A of current. It can be used for bridging the supply voltage from one electronic module to another. The voltage at the cross-connector must not exceed 50 V. Ventilation slits Diagonal ventilation slits ventilate the lower parts of the enclosures and keep temperatures moderate. SSB_K001-K007_GB 24.10.2003 11:58 Uhr Seite K.7 Relay coupler - overview Relay coupler Enclosure types for relay couplers RS SERIES DK SERIES EG SERIES Clip-in bases with relay RS 30, 31, 32 have a width of 11.2 mm to 25 mm, depending on the type. The open snap-in profile means that relay couplers can be designed for plugging in. The modules on the snap-in base have screw clamp units or flat plug-in connections for connection to the conductor. The following conductors can be connected: All components in the DKR mini-coupler are extremely narrow: use of advanced surface-mounted parts (SMD) allows the width to be kept to just 6 mm. The range includes 4 or 5 screw connections for conductor cross-sectional areas of 0.5 ... 4 mm2. The mini couplers offer a wide range of applications for coupling digital sensor/actuator signals with automation devices and the process field. DKR relay couplers can be used to pick up and standardise signals from the field with different voltages. The EG7 integral enclosure has a special status because it is only suited for the installation of 10 mm narrow relay couplers. EG7 clip-in base can be mounted on either the TS 32 or TS 35. An RS EG7 snap-in base is also available for the RST plug-in relay couplers. MCZ SERIES * Change-over contact RST: 0.5 ... 2.5 mm2. * Solid: 0.5...4 mm2, * Flexible: 0.5...2.5 mm2. Snap-in base with multiple interface RSM multiple interfaces are assembled with a choice of 4, 8 or 16 relays. Versions with a joint plus or minus potential are available to save wiring on the input side. LP connection elements are equipped screw connections and are suitable for connecting the following conductor cross-sectional areas: * Solid: 0.5...4 mm , 2 The MCZ enclosure is only 6 mm wide and one of the narrowest of its kind. Its outstanding technical features include: The closed EG 7 enclosures are equipped with screw connections. Conductors with the following cross-sectional areas can be connected: * Integral enclosure EG 7: 0.5 ... 1.5 mm2 * Tension clamp connection to reduce assembly costs * Integrated input/output cross-connection to reduce wiring workload K * Flexible: 0.5...2.5 mm2. Variations on the RSM coupler have prefabricated male connectors acc. to IEC 603-1/DIN 41 651. MCZR mini-conditioners (relay couplers) have 4 or 5 tension clamp connections. The cross-sectional area of the clamping conductor is 0.5 ... 1.5 mm2. K.7 SSB_K008-K059 25.10.2003 11:14 Uhr Seite K.8 PLUGSERIES 1 change-over contact Relay coupler Construction kit consists of * Relay-socket for mounting-rail * LED-indicator / RC-combination * Retaining bracket * Pluggable relay Cross-connection of the coil connections and change-over contacts of the relay with pluggable cross-connection ZQV 2.5N DC version 14 12 A1 A2 AC version 14 12 A1 A2 Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 250V/10A 10V/100mA 5.8ms/6.9ms AgNi 90/10 30x10^6 switching cycles 0.1Hz LED green/Yes/not available -25 C...+50 C -40 C...+50 C 40C/93% rel. humidity without condensation CE, cURus EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 250V 6 kV >8mm III 2 Yes Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 2.5 / 0.5 / 2.5 92.0 / 15.3 / 95.0 mm2 mm Tension clamp connection 2.5 / 0.5 / 2.5 92.0 / 15.3 / 87.0 Information Applications Coil operating range DC K DC voltage [Vdc] resistive Load Coil voltage (U/Un) Max. DC load breaking capacity . . . . . . Un nominal coil voltage . . . . DC current [A] Ambient temperature [C] Coil operating range AC 250Vac resistive load 12/16A DC-coile Coil voltage (U/Un) Operations Electricial life . . . . . . AC-coile . Un nominal coil voltage . . Switching current [A] Ambient temperature [C] SSB_K008-K059 25.10.2003 11:14 Uhr Seite K.9 PLUGSERIES Relay coupler 1 change-over contact Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 12VDC 1CO 24VDC 1CO 115VDC 1CO 24VAC 1CO 12 Vdc +/- 20 % 24 Vdc +/- 10 % 115 Vdc +/- 10 % 24 Vac +/- 10 % 32mA 33mA 400mW 16mA 400mW 3.5mA 400mW 8.4V/1.2V 16.8 V / 2.4 V 76 V / 11 V PRS 12Vdc LD 1CO PRS 24Vdc LD 1CO PRS 115Vdc LD 1CO 8536471001 8530621001 8536510000 8536530000 PRZ 12Vdc LD 1CO PRZ 24Vdc LD 1CO PRZ 115Vdc LD 1CO PRZ 24Vac LD 1CO 8536571001 8530691001 8536610000 8536651001 RCL 314012 12Vdc-Rel1U RCL 314024 24Vdc-Rel1U RCL 314110 110Vdc-Rel1U RCL 315524 24Vac-Rel1U 4058470000 4058480000 4058500000 4058510000 120VAC 1CO 230VAC 1CO 120 Vac +/- 10 % 6.6mA 230 Vac +/- 10 % 3.2mA 0.75VA 86.3V/17.3V 0.75VA 171 V / 34 V PRS 120Vac LD 1CO PRS 230Vac LD 1CO 0.75VA 17V/3.6V Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. PRS 24Vac LD 1CO Ordering data Spare relay, pluggable Type Order No. Information Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. 8530641001 8530671001 PRZ 120Vac LD 1CO PRZ 230Vac LD 1CO 8530710000 8530731001 RCL 314615 115Vac-Rel1U RCL 314730 230Vac-Rel1U 4058520000 4058540000 Ordering data Spare relay, pluggable Type Order No. Information K SSB_K008-K059 25.10.2003 11:14 Uhr Seite K.10 PLUGSERIES 2 change-over contacts Relay coupler Construction kit consists of * Relay-socket for mounting-rail * LED-indicator / RC-combination * Retaining bracket * Pluggable relay Cross-connection of the coil connections and change-over contacts of the relay with pluggable cross-connection ZQV 2.5N DC version 14 12 A1 A2 24 22 21 11 AC version 14 12 A1 A2 24 22 11 21 Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 250V/10A 10V/100mA 9ms/45ms AgNi 90/10 5x10^6 switching cycles 0.1Hz LED green/No/ -40 C...+50 C -40 C...+50 C 40C/93% rel. humidity without condensation CE, cURus EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 250V 6 kV >8mm III 2 Yes Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 2.5 / 0.5 / 2.5 92.0 / 15.3 / 95.0 mm2 mm Tension clamp connection 2.5 / 0.5 / 2.5 92.0 / 15.3 / 87.0 Information Applications Coil operating range DC 2-pole resistive load K 2 contacts in series Coil voltage (U/Un) Max. DC load breaking capacity . . . . DC voltage [Vdc] 1 contact . . Un nominal coil voltage . . . . DC current [A] Ambient temperature [C] Coil operating range AC 250Vac resistive load Coil voltage (U/Un) Operations Electrical life . . . . . DC-coil AC-coil . . Un nominal coil voltage . . Switching current [A] Ambient temperature [C] SSB_K008-K059 25.10.2003 11:14 Uhr Seite K.11 PLUGSERIES Relay coupler 2 change-over contacts Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 12VDC 2CO 24VDC 2CO 115VDC 2CO 24VAC 2CO 12 Vdc +/- 20 % 24 Vdc +/- 10 % 115 Vdc +/- 10 % 24 Vac +/- 10 % 32mA 33mA 400mW 16mA 400mW 3.5mA 400mW 8.4 V / 1.2 V 16.8 V / 2.4 V 76 V / 11 V PRS 12Vdc LD 2CO PRS 24Vdc LD 2CO PRS 115Vdc LD 2CO 8536501001 8530631001 8536520000 8536560000 PRZ 12Vdc LD 2CO PRZ 24Vdc LD 2CO PRZ 115Vdc LD 2CO PRZ 24Vac LD 2CO 8536591001 8530701001 8536630000 8536681001 RCL 424012 12Vdc-Rel2U RCL 424024 24Vdc-Rel2U RCL 424110 110Vdc-Rel2U RCL 424524 24Vac-Rel2U 4058560000 4058570000 4058590000 4058600000 120VAC 2CO 230VAC 2CO 120 Vac +/- 10 % 6.6mA 230 Vac +/- 10 % 3.2mA 0.75VA 86.3V/17.3V 0.75VA 172.5V/34.5V PRS 120Vac LD 2CO PRS 230Vac LD 2CO 0.75VA 17V/3.6V Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. PRS 24Vac LD 2CO Ordering data Spare relay, pluggable Type Order No. Information Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. 8530661001 8530681001 PRZ 120Vac LD 2CO PRZ 230Vac LD 2CO 8530720000 8530741001 RCL 424615 115Vac-Rel2U RCL 424730 230Vac-Rel2U 4058610000 4058630000 Ordering data Spare relay, pluggable Type Order No. Information K SSB_K008-K059 25.10.2003 11:14 Uhr Seite K.12 PLUGSERIES Relay coupler 2 change-over contacts with gold-plated contacts Construction kit consists of * Relay-socket for mounting-rail * LED-indicator / RC-combination * Retaining bracket * Pluggable relay Cross-connection of the coil connections and change-over contacts of the relay with pluggable cross-connection ZQV 2.5N DC version 14 12 A1 A2 24 22 21 11 AC version 14 12 A1 A2 11 Ordering data K Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 24 22 21 Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 250V/10A 5 V / 10 mA 9ms/45ms AgNi 90/10 5x10^6 switching cycles 0.1Hz LED green/No/ -40 C...+50 C -40 C...+50 C 40C/93% rel. humidity without condensation CE, cURus EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 250V 6 kV >8mm III 2 Yes Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 2.5 / 0.5 / 2.5 92.0 / 15.3 / 95.0 mm2 mm Information 24VDC 2CO AU 120VAC 2CO AU 230VAC 2CO AU 24 Vdc +/- 10 % 120 Vac +/- 10 % 6.6mA 230 Vac +/- 10 % 3.2mA 0.75VA 86.3V/17.3V 0.75VA 172.5V/34.5V PRS 24VDC LD 2COAU PRS 120VAC LD 2CO AU PRS 230VAC LD 2CO AU 8561760000 8595960000 8595990000 PRZ 24Vdc LD 2CO AU PRZ 120VAC LD 2COAU PRZ 230VAC LD 2COAU 8552440000 8575940000 8575950000 RCL 425024 24Vdc-Rel2U RCL 425615 115Vac-Rel2U RCL 425730 230Vac-Rel2U 4058580000 4058620000 4058640000 16mA 400mW 16.8 V / 2.4 V Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information Tension clamp connection 2.5 / 0.5 / 2.5 92.0 / 15.3 / 87.0 SSB_K014-K019_GB 24.10.2003 12:53 Uhr Seite K.14 PLUGSERIES Accessories Schrack RP3SL Relay coupler Relay for high switch-on current Marking field Retaining clip Cross-connection channel A1 / A2 92 92 Tension clamp connection Screw connection 15,3 87 (PXZ35) 87 95 (PXS35) Cross-connection channel 11 / 21 15.3 Technical data Empty base Rated current Rated voltage Voltage resistance coil / contacts Protection Nominal cross-sectional area Stripping length 15.3 16 A 250 V > 4 kV IP 20 2,5 mm2 Screw connection Tension clamp connection Ambient temperature Flammability acc. to UL 94 8 mm 10 mm -40C ... +60C V-0 Order data Empty base for assembly on mounting rail TS 35 Screw connection Tension clamp connection Type PXS35 PXZ35 Qty 10 10 Order no. 8533771001 8536691001 PRC 100 8536700000 22 12 (NC) 22 12 (NC) 21 11 (COM) 21 11 (COM) 24 14 (NO) 24 14 (NO) A2 A1 (COIL) A2 A1 (COIL) Retaining clip K Operating control display LED display with freewheel diode 6 ... 24 Vdc LED red, 6 ... 24 Vdc 48 ... 60 Vdc 115 Vdc 12 ... 24 Vac 115 Vac 230 Vac LED red, 230 Vac RC combination 120...230 VAC/DC Plug-in cross-connectors 2-pole PLED 24 Vdc PLED 24 Vdc rot PLED 48 Vdc PLED 115 Vdc PLED 24 Vac PLED 120 Vac PLED 230 Vac PLED 230 Vac rot PLRC 200 nF/200 20 20 20 20 20 20 20 20 20 8536710000 8611010000 8536720000 8536730000 8536750000 8536760000 8536780000 8611000000 8566530000 ZQV 2.5N/4-2SW ZQV 2.5N/4-2RT ZQV 2.5N/4-2BL 60 60 60 1784270000 1784280000 1784290000 200 96 1060860000 1609880000 DC version 14 A1 12 24 22 * A2 21 11 AC version Black Red Blue A1 14 12 24 22 Marking 10 x 5 mm 15 x 5 mm K.14 WS 10/5 WS 15/5 A2 11 21 wheel * free diode SSB_K014-K019_GB 24.10.2003 12:53 Uhr Seite K.15 PLUGSERIES Relay on plug-in base Schrack RP3SL Relay coupler * For high switch-on current Technical data No. and type of contacts Contact material Switching current Peak switch-on current Switching voltage 1 NOC AgSnO2 25 A 120 A / 20 ms 250 V Switching power Min. switching current / switching power Nominal consumption Voltage strength / contact Operating voltage / release time: Bounce time NCC / NOC Mechanical service life 4 kVA Other data Protection class Ambient temperature Weight Approvals Contact service life DC coil DC coil DC coil Load 12 A, 250 V~, cos=1 TV 8 2500 W, 230 V~, Halogen lamps 1000 W, 250 V~, Neon lamps 3000 W, 250 V~, Neon lamps 1500 VA, Fluorescent tubes 163 F 500 mW 4 kV typ. 8 / 2 ms typ. 2 ms 30 x 106 switching cycles IP 40 -40C ... +70C 18 g SEV, UL, CSA, VDE Switching cycles 3x105 25x103 >104 2.3x105 3.6x104 104 Regulation UL 508 K Order data Pluggable relay 24 Vdc 1 NOC Type RP3SL 24 Vdc 1NO Qty 20 Order no. 8588510000 K.15 SSB_K014-K019_GB 24.10.2003 12:53 Uhr Seite K.16 PLUGINDUSTRY Relay coupler Base for industrial relays PXZ4 PXS4 Tension clamp Screw connection Rated current Rated voltage Voltage strength coil / contacts Creepage and clearance path input / output Protection class 5 A bei 70 C with MY4 relay 250 Vac 2000 Vac 2000 Vac IP 20 5 A bei 70 C with MY4 relay 250 Vac 2000 Vac 2000 Vac IP 20 Nominal cross-sectional area Stripping length Ambient temperature Combustibility acc. to UL 94 Approvals 0.2...1.5 mm2 (doubled) 8 mm max. 70 C V-1 0.2...1.5 mm2 8 mm max. 70 C V-1 m a r% a r% * Screw or tension clamp technology * For connecting cross-sectional areas up to 1.5 mm2 * For double and quadruple change-over contact relays * Insulation in accordance with VDE 0110 * Tension clamp connection - Minimum wiring workload - Double wiring of all terminals - Connections can be cross-connected - Separate arrangement of coil and contact connections Wiring method for tension clamp connection Place the specified screwdriver in the round tool opening next to the square wire opening Wire opening Tool opening 41 31 21 11 Technical data Order data Empty base for mounting rail assembly TS 35 Type PXZ4 Qty 10 Order no. 8598710000 Type PXS4 Qty 10 Order no. 8614350000 Retaining clip Relay, type: MY4 Relay, type: PT5 Type PXZ4-PIRC PT 28802 Qty 50 25 Order no. 8598610000 8572170000 Type PXS4-PIRC Qty 100 Order no. 8633920000 Marking for PXZ4-PIRC only WS PXZ4 100 8598630000 50 50 8611090000 8611100000 1 9009030000 K Accessories Cross-connector 2-pole Blue Red ZQV PXZ4-bl ZQV PXZ4-rt Screwdriver SD K.16 Articles with coloured order number are kept permanently in stock at the central warehouse in Germany. Delivery times see page X.2 SSB_K014-K019_GB 24.10.2003 12:53 Uhr Seite K.17 PLUGINDUSTRY MY4 IN / MY4 IN1 Miniature power relay MY4 Relay coupler * Relay with 4 change-over contacts * With DC or AC voltage coil * Mechanical operating display * Integrated LED for optical operating display * Test button (blue = DC coil, red = AC coil) * Cadmium-free contacts with 3 m gold plating Breaking capacity * For plugging onto Weidmuller base PXZ4 and PXS4 100 Switching current (A) 50 Technical data Coil data Rated voltage Rated power Operating voltage/release voltage General data Flammability class acc. to UL 94 Ambient temperature Mechanical service life Response/release time Duration of bounce Weight Dimensions (width x height x length) AC resistive load 10 AC inductive load (cos =0,4) 5 3 DC resistive load 1 0,5 AC coil 24 / 120 / 230 V~ Typically 1.0 VA 80 / 30 (% rated voltage) DC induktive load (L/R= 7 ms) 0,3 0,1 1 3 5 10 30 50 100 250 500 Switching voltage (V) DC coil / AC coil 4 change-over contacts AgNi with 3m Au plating 4x5A 125 V- / 250 V~ 1250 VA 4x5A 5 Vdc, 10 mA Lifetime (inductive load) 1000 500 DC coil / AC coil Insulation Voltage strength coil-contact Insulation acc. to IEC 664 / VDE 0110 (1/89) Rated voltage / pollution severity / overvoltage category Insulation acc. to VDE 0110b (2/79) Insulation group/reference voltage V-2 -55...+70 C >10x107 / >50x106 20 / 20 ms max. 20 ms 35 g 21.5 x 36 x 28 mm 300 Lifetime (x104 operations) Contact data No. of contacts Contact material Rated current Switching voltage max. Max. switching power AC Switching current Recommended min. load DC coil 12 / 24 / 110 VTypically 0.9 W 80 / 10 (% rated voltage) 30 2000 Vac 30 VDC 100 50 30 VDC 30 250 VAC 10 250 VAC 5 3 240 V / 2 / II 1 0 0,5 A250 / B125 1 1,5 2 Switching current (A) K Lifetime (resistive load) Order data 12 Vdc 24 Vdc 110 Vdc Type MY4 IN1-12 MY4 IN1-24 MY4 IN1-110 Qty 10 10 10 Order no. 8598660000 8598700000 8598640000 AC coil 24 Vac 120 Vac 230 Vac MY4 IN-24 MY4 IN-120 MY4 IN-230 10 10 10 8598690000 8598650000 8598670000 1000 500 Lifetime (x104 operations) DC coil 300 250 VAC 100 50 30 30 VDC 30 VDC 10 250 VAC 5 3 1 0 1 2 3 4 5 Switching current (A) Other relays on request K.17 SSB_K014-K019_GB 24.10.2003 12:53 Uhr Seite K.18 PLUGINDUSTRY Relay coupler Miniature power relay PT 5 PT 5 * Relay with 4 change-over contacts * With DC or AC voltage coil * Mechanical operating display * Locking test button * Cadmium-free contact material * For plugging onto Weidmuller base PXZ4 with retaining clip PT 28802 Max. DC load breaking capacity Technical data DC coil 6...220 VTypically 0.75 W 75 / 10 (% rated voltage) 90...110 % Urated Contact data No. of contacts Contact material Rated current Switching voltage max. Max. switching power AC Switching current Recommended min. load 4 change-over contacts AgNi 90 / 10, AgNi 90 / 10 htv 4x6A 250 Vac 1500 VA 4x6A 24 V, 10 mA / 20 mV, 1 mA htv General data Flammability class acc. to UL 94 Ambient temperature Mechanical service life Response/release time Duration of bounce width x height x length DC coil / AC coil DC coil / AC coil Insulation Voltage strength coil-contact Insulation acc. to IEC 664 / VDE 0110 (1/89) Rated voltage / pollution severity / overvoltage category Insulation acc. to VDE 0110b (2/79) Insulation group/reference voltage AC coil 6...230 V~ Typically 1.0 VA 80 / 10 (% rated voltage) 4 pole 3 pole 2 pole in series contacts contacts contacts pole DC current [A] Electrical life Operations Coil data Rated voltage Rated power Operating voltage/release voltage Working range AC coil, 60 Hz at 70C DC voltage [Vdc] resistive load V-0 -40...+70C > 30 x 106 (DC coil), > 20 x 106 (AC coil) 15 / 10 ms 5 ms 22.5 x 30 x 28 mm resistive load 2500 Veff 240 V / 2 / III DC current [A] B / 250 K Order data 6 12 24 48 60 115 220 Vdc Vdc Vdc Vdc Vdc Vdc Vdc Type PT 570006 PT 570012 PT 570024 PT 570048 PT 570060 PT 570110 PT 570220 6 12 24 48 60 115 230 Vac Vac Vac Vac Vac Vac Vac PT PT PT PT PT PT PT Qty 10 10 10 10 10 10 10 Order no. 8074650000 8054360000 1180700000 8074670000 8074680000 8074700000 8636230000 10 10 10 10 10 10 10 8074710000 8074730000 1181800000 1180900000 8074760000 1180800000 1181100000 Coil voltage (U/Un) Coil operating range DC DC coil AC coil 570506 570512 570524 570548 570560 570615 570730 Other relays on request K.18 nominal voltage Ambient temperature [C] SSB_K008-K059 21.10.2003 16:42 Uhr Seite K.20 MICROSERIES Relay coupler 1 change-over contact Module can be used as an universal interface between control and actuator for switching small and medium loads * The pluggable cross-connection in input and output minimizes the effort to wire * Width 6.1 mm * Relay interchangeable, also with opto-couplers 11 14 A2 (5/12Vdc) 12 A1 11 (24/60 Vdc) 14 A2 12 A1 11 (24/48/120 Vuc) 14 A2 12 A1 Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 250V/6A 12V/100mA 6.2ms/3.9ms AgSnO 20x10^6 switching cycles 0.1Hz LED green/Yes/available -25 C...+50 C -40 C...+60 C 40C/93% rel. humidity without condensation CE, cURus EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 300 V 4 kV =>5.5mm III 2 Yes Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 2.5 / 0.5 / 4 93.0 / 6.1 / 92.0 11 (230 Vac) 14 A2 A1 12 mm2 mm Tension clamp connection 1.5 / 0.5 / 2.5 94.0 / 6.1 / 91.0 Information Applications DC-load breaking capacity capa Switch operations AC resistive load K voltage [A] 200 0 0.1 5 currentt [A] curre Switch ch operations Output current [A] Derating curve Ambient temperature [C] acc. to SSB_K008-K059 21.10.2003 16:42 Uhr Seite K.21 MICROSERIES Relay coupler 1 change-over contact Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 5VDC 1CO 12VDC 1CO 24VDC 1CO 24VUC 1CO 5 Vdc +/- 20 % 12 Vdc +/- 20 % 24 Vdc +/- 20 % 38.5mA 193mW 17mA 210mW 6.6mA 160mW 3.2V/1.6V 6.4V/2.5V 15.4V/6.5V 21.6mA/8mA 8.4mA/2.4mA 4mA/1.2mA 24 Vuc +/- 10 % 11mA 6.4mA 154mW 15.8V/7V 15.8V/7V 3.6mA/1.3mA 3.6mA/1.3mA MRS 5Vdc 1CO MRS 12Vdc 1CO MRS 24Vdc 1CO MRS 24Vuc 1CO 8556080000 8556070000 8533640000 8556050000 MRZ 5Vdc 1CO MRZ 12Vdc 1CO MRZ 24VDC 1U MRZ 24Vuc 1CO 8556150000 8556140000 8533660000 8556120000 APE 30005V 05Vdc-Rel1U APE 30012V 12Vdc-Rel1U APE 30024V 24Vdc-Rel1U APE 30024V 24Vdc-Rel1U 4061580000 4061610000 4060120000 4060120000 48VUC 1CO 60VDC 1CO 120VUC 1CO 230VAC 1CO 48 Vuc +/- 10 % 5mA 4mA 190mW 29V/11V 29V/11V 2.2mA/1.3mA 2.2mA/1.3mA 60 Vdc +/- 20 % 230 Vac +/- 10 % 7.6mA 1.6mA/0.6mA 120 Vuc +10 %/ -15 % 3.5mA 3.5mA 0.42VA 71V/22V 71V/22V 1.8mA/0.5mA 1.8mA/0.5mA MRS 48Vuc 1CO MRS 60Vdc 1CO MRS 120Vuc 1CO MRS 230Vac 1CO 8556040000 8556060000 8556030000 8556020000 MRZ 48Vuc 1CO MRZ 60Vdc 1CO MRZ 120Vuc 1CO MRZ 230Vac 1CO 8556110000 8556130000 8556100000 8556090000 APE 30048V 48Vdc-Rel1U APE 30060V 60Vdc-Rel1U APE 30060V 60Vdc-Rel1U APE 30024V 24Vdc-Rel1U 4061620000 4061630000 4061630000 4060120000 Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 3.3mA 200mW 35V/11V 1.75VA 103V/49V 103V/49V 5mA/2.5mA 5mA/2.5mA Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information K SSB_K008-K059 21.10.2003 16:42 Uhr Seite K.22 MICROSERIES Relay coupler 1 change-over contact with gold-plated contact Module can be used as an universal interface between control and actuator for switching small and medium loads * The pluggable cross-connection in input and output minimizes the effort to wire * Width 6.1 mm * Relay interchangeable, also with opto-couplers 11 A2 14 (24Vdc) A1 12 11 A2 14 (120 Vuc) A1 12 11 A2 14 (230 Vac) 12 A1 Ordering data K Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 2.5 / 0.5 / 4 93.0 / 6.1 / 92.0 Information 24 Vdc +/- 20 % 230 Vac +/- 10 % 7.6mA 4mA/1.2mA 1.75VA 103V/49V 103V/49V 5mA/2.5mA 5mA/2.5mA MRS 24Vdc 1CO 5uAu MRS 230Vac 1CO 5uAu Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. 8596060000 8596050000 MRZ 24Vdc 1CO 5uAu MRZ 230Vac 1CO 5uAu 8596080000 8596070000 APE 30124V 24Vdc-Rel1U APE 30124V 24Vdc-Rel1U 4061590000 4061590000 Ordering data Spare relay, pluggable Type Order No. Information EN 50178 300 V 4 kV =>5.5mm III 2 Yes 230VAC 1CO 5uAU 15.4V/6.5V LED green/Yes/available -25 C...+50 C -40 C...+60 C 40C/93% rel. humidity without condensation CE, cURus Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 24VDC 1CO 5uAU 6.6mA 160mW 250V/6A 12V/10mA 6.6ms/5.8ms AgSnO 5 #03BCm Au 20x10^6 switching cycles 0.1Hz mm2 mm Tension clamp connection 1.5 / 0.5 / 2.5 94.0 / 6.1 / 91.0 SSB_K023-K023_GB 24.10.2003 15:43 Uhr Seite K.23 MICROSERIES General data - MICROSERIES Relay coupler Accessories Pluggable cross-connector No. of poles Technical data Type Yellow ZQV 4N / ZQV 4N / ZQV 4N / ZQV 4N / ZQV 4N / Qty Order no. 2 GE 3 GE 4 GE 10 GE 41 GE 2 3 4 10 41 60 60 60 20 10 1758250000 1762630000 1762620000 1758260000 1758270000 Red ZQV 4N ZQV 4N ZQV 4N ZQV 4N ZQV 4N / / / / / 2 RT 3 RT 4 RT 10 RT 41 RT 2 3 4 10 41 60 60 60 20 10 1793950000 1793980000 1794010000 1794040000 1794070000 Blue ZQV 4N ZQV 4N ZQV 4N ZQV 4N ZQV 4N / / / / / 2 BL 3 BL 4 BL 10 BL 41 BL 2 3 4 10 41 60 60 60 20 10 1793960000 1793990000 1794020000 1794050000 1794080000 Black ZQV 4N ZQV 4N ZQV 4N ZQV 4N ZQV 4N / / / / / 2 SW 3 SW 4 SW 10 SW 41 SW 2 3 4 10 41 60 60 60 20 10 1793970000 1794000000 1794030000 1794060000 1794090000 Other accessories Type Marker WS 12/6 Clamping conductor Solid H07V-U Flexible H07V-K "f" with ferrule acc. to DIN 46 228 / 1 "f" with ferrule with plastic collar Max. clamping range Plug gauge acc. to IEC 60-947-1 mm2 mm2 mm2 mm2 mm2 Size General technical data Rated torque Continuous output current of the 2-pole cross-connector A Continuous output current of the multi-pole cross-connector A Stripping length mm Protection class Enclosure material Flammability class acc. to UL 94 Rated current A Rated voltage V Tension clamp connection 0.5 ... 2.5 0.5 ... 2.5 0.5 ... 1.5 0.5 ... 1.5 0.13 ... 2.5 A2 Screw connection 0.5 ... 4.0 0.5 ... 2.5 0.5 ... 1.5 0.5 ... 1.5 0.13 ... 4.0 A3 10 10 10 IP 20 Wemid V-0 6 250 0,6 10 10 7 IP 20 Wemid V-0 6 250 Dimensional drawings 12 x 6 mm Qty Order no. 200 1061160000 Tension clamp Screw connection 1686360000 10 9008330000 94 mm 92 mm 10 93 mm 6.1 mm Screwdriver SD 0.6 x 3.5 x 100 484 Labels / sheet 6.1 mm Labels, laser mark LM MT 300 15/6 ge 91 mm K K.23 SSB_K008-K059 25.10.2003 11:38 Uhr Seite K.24 WAVESERIES Relay coupler 1 change-over contact 250 V / 4 A 2,4 V...24 Vdc 1 Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 7 12 0V 11 8 2 14 24 Vdc 9 3 WRS 1 12,4-24 Vdc 250 V / 4 A 7 1 12 A2 11 0V 2 8 14 A1 + 3 24 Vdc 9 WRS 24 Vdc A1 + 1 250V/5A 100mA/5Vdc 7ms/6ms Ag alloy 20x10^6 switching cycles 0.1Hz LED green/Yes/available -25 C...+50 C -40 C...+60 C 40C/93% rel. humidity without condensation UL / CSA EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 300 V 6 kV (1.2/50 ) =>5.5mm III 2 Yes Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 1.5 / 0.5 / 2.5 72.0 / 22.5 / 92.4 250 V / 4 A 24 Vuc 7 12 A3 2 11 0V 8 14 A2 48 Vuc 3 9 WRD 24/xxVuc Information Applications K Output current [A] Mounted horizontally 8 7 6 5 4 3 2 1 0 Clearance > = 10mm 0 20 40 60 80 100 Ambient temperature [C] mm2 mm Tension clamp connection SSB_K008-K059 25.10.2003 11:38 Uhr Seite K.25 WAVESERIES Relay coupler 1 change-over contact Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 2.4-24VDC 1CO 24VDC 1CO 24/48VUC 1CO 24/60VUC 1CO 2.4...24 Vdc +/-10 % 24 Vdc +/- 10 % 4.6mA 200 mW 9mA 220mW 1.9 V 16 V/7.5 V 3.88mA 5.7 mA/2.2 mA 24 Vuc // 48 Vuc, +/- 10 % approx. 14mA 14 mA 0.35VA(W) // 0.5VA(W) 16 V/9.5 V // 29 V/15 V 16 V/9.5 V // 29 V/15 V 9 mA/4.5 mA // 8.3mA/4.1mA 9 mA/4.5 mA // 8.3mA/4.1mA 24 Vuc // 60 Vuc, +/- 10 % approx. 11mA approx. 10mA 0.22W / 0.34VA // 0.6W / 0.7VA 16 V/9.5 V // 31 V/20 V 15 V/8,5V // 34 V/15 V 5.6mA/2.3mA // 5.6mA/2.1mA 5.8 mA/3.9 mA // 5.6 mA/3.4 mA WRS1 2.4-24VDC 1U WRS1 24VDC 1U WRS1 24/48VUC 1U WRS1 24/60VUC 1U 8275320000 8275350000 8286280000 8418210000 24/115VUC 1CO 24VUC/230VAC 1CO 24 Vuc // 115 Vuc, +/- 10 % approx. 11mA approx. 10mA 0.22W / 0.34VA // 1.2W / 1.3VA 15 V/12 V // 60 V/34 V 16V/8.5V // 64V/26V 5.8mA/3.9mA // 5.5mA/3mA 5.6mA/2.3mA // 5.7mA/2.2mA 24 Vuc // 230 Vac, +/- 10 % approx. 15mA 14mA (24Vdc) 0.34VA / 0.32W // 3.5VA 13 V/9 V // 115 V/66 V 13 V/9 V (24Vdc) 7.5 mA/4.7 mA // 7.4 mA/4.3 mA 7.5 mA/4.7 mA WRS1 24/115VUC 1U WRS1 24VUC/230VAC 1U 8418220000 8418230000 Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information K SSB_K008-K059 25.10.2003 11:38 Uhr Seite K.26 WAVESERIES Relay coupler 2 NO contacts Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards Derating curve Output current [A [ 8 7 6 5 4 3 2 1 0 clearance > 10mm mounted 0 10 20 30 40 50 60 70 80 Ambient temperature (C) A1 1 23 13 A2 2 0V 24 14 A3 3 7 10 8 11 9 12 250V/5A 100mA/5Vdc 5ms/6ms AgSnO2 50x10^6 switching cycles 0.1Hz LED green/Yes/available -25 C...+50 C -40 C...+60 C 40C/93% rel. humidity without condensation UL / CSA EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 300 V 6 kV (1.2/50 ) =>8mm III 2 Yes Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 1.5 / 0.5 / 2.5 92.4 / 22.5 / 112.4 mm2 mm Information Ordering data K Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 12/24VDC 2A 24/48VUC 2A 115VUC/230VAC 2A 12 Vdc // 24 Vdc, +/- 10 % 10 mA/4.2 mA // 10 mA/4 mA 24 Vuc // 48 Vuc, +/- 10 % approx. 11mA approx. 8.5mA 0.17W / 0.21VA // 0.4W / 0.48VA 13.5 V /9 V // 24 V/16 V 16 V /7.8 V // 28 V/12 V 4.4 mA/2.7 mA // 4.3 mA/2.6 mA 4.3 mA/1.6 mA // 4.4 mA/1.6 mA 115 Vuc // 230 Vac, +/- 10 % approx. 10mA 9mA (115Vdc) 1VA / 0.9W // 2.5VA 58 V /22 V // 110 V/40 V 54 V /20 V (115Vdc) 4.8 mA/1.7 mA V // 5 mA/2 mA 4 mA/2 mA WRS2 12/24VDC 2A WRS2 24/48VUC 2A WRS2 115VUC/230VAC 2A 8418240000 8418250000 8418260000 approx. 20mA 0.24W // 0.5W 7.5 V /3.5 V // 14.5 V/6.1 V Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information Tension clamp connection SSB_K008-K059 25.10.2003 11:38 Uhr Seite K.27 WAVESERIES Relay coupler 1 NC contact / 1 NO contact Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards Derating curve [ Output current [ A g 8 7 6 5 4 3 2 1 clearance >10mm mounted 0 0 A1 A2 A3 20 40 60 Ambient temperature [C] 80 11 13 1 0V 2 100 7 10 8 11 12 14 9 12 3 250V/5A 100mA/5V 7ms/5ms AgSnO2 50x10^6 switching cycles 0.1Hz LED green/Yes/available -25 C...+50 C -40 C...+60 C 40C/93% rel. humidity without condensation UL / CSA EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 300 V 6 kV (1.2/50 ) =>8mm III 2 Yes Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 1.5 / 0.5 / 2.5 92.4 / 22.5 / 112.4 mm2 mm Information Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 12/24VDC 1A 1R 24/48VUC 1A1R 115VUC/230VAC 1A 1R 12 Vdc // 24 Vdc, +/- 10 % 10 mA/4.2 mA // 10 mA/4 mA 24 Vuc // 48 Vuc, +/- 10 % approx. 11mA approx. 8.5mA 0.17W / 0.21VA // 0.4W / 0.48VA 13.5 V /9 V // 24 V/16 V 13.5 V /9 V // 24 V/16 V 4.4 mA/2.7 mA // 4.3 mA/1.6 mA 4.3 mA/1.6 mA // 4.4 mA/1.6 mA 115 Vuc // 230 Vac, +/- 10 % approx. 10mA 9mA (115Vdc) 1VA / 0.9W // 2.5VA 58 V /22 V // 110 V/40 V 54 V /20 V (115Vdc) 4.8 mA/1.7 mA // 5 mA/2 mA 4 mA/1.6 mA WRS2 12/24VDC 1A1R WRS2 24/48VUC 1A1R WRS2 115VUC/230VAC 1A1R 8418270000 8418280000 8418290000 approx. 20mA 0.24W // 0.5W 7.5 V /3.5 V // 14.5 V/6.1 V Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information Tension clamp connection K SSB_K008-K059 25.10.2003 11:38 Uhr Seite K.28 WAVESERIES Relay coupler 2 change-over contacts Derating curve Output current [A [ 0,08 0,07 0,06 0,05 0,04 0,03 0,02 0,01 clearance > 10 mm mounted 0 0 10 20 30 40 50 60 80 70 Ambient temperature [C] 1A1 1A3 1A2 2A1 2A3 2A2 1 9 3 8 2 7 4 12 6 11 10 5 Ordering data K Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 114 112 111 Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 250V/5A 100mA/5Vdc 6ms/10ms Ag alloy 20x10^6 switching cycles 0.1Hz LED green/Yes/available -25 C...+50 C -40 C...+60 C 40C/93% rel. humidity without condensation UL / CSA EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 300 V 6 kV (1.2/50 ) =>5.5mm III 2 Yes Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 1.5 / 0.5 / 2.5 92.4 / 22.5 / 112.4 214 212 211 mm2 mm Information 12/24VDC 2CO 24/48VUC 2CO 24VUC/230VAC 2CO 12 Vdc // 24 Vdc, +/- 10 % 24 Vuc // 48 Vuc, +/- 10 % approx. 15mA 14 mA 0.35VA(W) // 0.7VA(W) 16V/9.5V // 29V/15V 9 mA/4.5 mA // 8.3mA/4.1mA 9 mA/4.5 mA // 8.3mA/4.1mA 24 Vuc // 230 Vac, +/- 10 % approx. 15mA 14mA (24Vdc) 0.35W // 3.45VA 13 V/9 V // 115 V/66 V 13 V/9 V (24Vdc) 7.5 mA/4.7 mA // 7.4 mA/4.3 mA 7.5 mA/4.7 mA WRS2 12/24VDC 2U WRS2 24/48VUC 2U WRS2 24VUC/230VAC 2U 8418300000 8418310000 8418320000 approx. 23mA 0.26W // 0.53W 8.5 V /3 V // 15 V/4.8 V 15.2 mA/5.7 mA // 15.3 mA/5.6 mA Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information Tension clamp connection SSB_K008-K059 25.10.2003 11:38 Uhr Seite K.29 WAVESERIES Relay coupler 3 NO contacts Derating curve Output current [ A [ 7 6 5 4 3 2 1 0 clearance >10mm mounted 0 20 40 60 80 100 Ambient temperature [C] 1A1 2 9 113 K1 1A2 2A1 8 3 5 11 114 213 K2 Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 250V/4A 12V/10mA 5ms/21ms AgSnO2 20x10^6 switching cycles 0.1Hz LED green/No/not available -25 C...+50 C -40 C...+60 C 40C/93% rel. humidity without condensation UL / CSA EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 300 V 6 kV (1.2/50 ) =>5.5mm III 2 Yes Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 1.5 / 0.5 / 2.5 92.4 / 22.5 / 112.4 12 6 2A2 214 3A1 1 10 313 K3 4 7 3A2 Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 314 Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information Tension clamp connection Information 24VUC 3A 230VAC 3A 24 Vuc +/- 10 % 10.4mA 10.5mA 0.3VA // 0.25W 12.8 V / 5 V 12.8 V / 5 V 6.6 mA / 2.1 mA 6.5 mA / 1.4 mA 230 Vac +/- 10 % 10.3mA WRS2 24VUC 3A WRS2 230VAC 3A 8418330000 8418340000 2.4VA 207V/207V/207V 9mA Ordering data Complete module Screw connection mm2 mm K SSB_K030-K031_GB 10.10.2003 9:39 Uhr Seite K.30 RS-SERIES / RS 30 Relay coupler 1 NCC, 1 NOC or 1 change-over contact RS 30 RS 30 Screw connection Isolating plug with screw connection 1 NOC 1 NCC 1 NOC 1 NCC 1 change-over contact 1 change-over contact Technical data Input voltage 5...60 V 10 %; 115 V/230 V + 5 % - 15% 5 VTTL 12 V- 24 V- 24 V0 48 V- 48 V0 60 V- 115 V~ 115 V- 230 V~2) 240 V~ Nominal consumption - (W) Nominal consumption ~ (VA) Release current of relay (at 20C) Release current of relay (at 20C) Pick-up current Output voltage max. Continuous current Derating curve a = arranged on mounting rail in horizontal row without spacing b = arranged on mounting rail in horizontal row with 20 mm spacing 0.45 W1) - - - - 250 V 5A 0.45 W - 3 mA - - 250 V 6A 0.45 W - 3 mA - 12 mA 250 V 6A 0.45 W 0.7 VA 2.5 mA- 3.5 mA~ - 250 V 6A 0.45 W - 2 mA - 10 mA 250 V 6A 0.45 W 0.6 VA 2.5 mA- 4.5 mA~ - 250 V 5A 0.45 W - 1 mA- - - 250 V 5A - 0.8 VA - 1 mA~ 6 mA 250 V 5A 0.82 W - 2 mA- - 4.3 mA 250 V 5A - 0.8 VA - 1 mA~ - 250 V 3A - 1.2 VA 0.5 mA- 1 mA~ - 250 V 3A Constant current Constant current spacing > 20 mm 48 V~ / 230 V~ / 240 V~ Switching mode on/off < 1 min (50 / 50 %) Continuous current Ambient temperature K Switch-on current Switch-on power under ohmic load Min. switching power/switching current Duration of bounce Typical switching times -, Pick-up delay -, Release delay Max. switching frequency Contact material Service life, mechanical -, 24 V-, 1A ohmic load -, 230 V-. 3A, ohmic load Storage temperature Ambient temperature, arranged on mounting rail -, in horizontal row without spacing -, in horizontal row with > 20 mm spacing Insulation coordination acc. to EN 50 178 Overvoltage category Pollution severity Dimensions Mounting width Length (at right angles to mounting rail) Hight (with TS 32 / TS 35 x 7.5) 8A 2000 VA / 100 W 250 mW / 10 mA 3 ms 8 ms 8 ms 8 ms 7 ms 7 ms 7 ms 70 Hz 70 Hz 70 Hz AgNi, gold-flashed >107 switching cycles > 5 x 105 switching cycles >7 x 105 switching cycles -40 C...+60 C 12 ms 11 ms 70 Hz -25 C...+40 C -25 C...+50 C III 2 11.2 mm NOC / NCC, 25 mm change-over contact 70 mm (74 mm BL/SL version) 56 mm / 51.5 mm 1) 2) K.30 8 ms 16 ms 30 Hz Rated consumption of auxiliary voltage 24 V-. 230 V- on request 13 ms 12 ms 20 Hz 12 ms 11 ms 70 Hz 9 ms 8 ms 30 Hz 12 ms 11 ms 70 Hz 10 ms 9 ms 30 Hz 10 ms 9 ms 30 Hz SSB_K030-K031_GB 10.10.2003 9:39 Uhr Seite K.31 RS 30 RS 30 Screw connection Isolating plug with screw connection A - 1 NOC DC B - 1 NOC AC/DC E - 1 change-over contact DC C - 1 NCC DC D - 1 change-over contact DC G - 1 NOC / 1NCC DC F - 1 change-over contact AC/DC Relay coupler RS-SERIES - RS 30 Order data Mail-line wiring diagram A B C D E F G Input voltage Function display NOC NOC NCC change-over contact change-over contact change-over contact NOC NCC 5 V-, TTL without 1167760000 1167660000 12 V- without LED red 1129421001 1129521001 24 V- without LED green LED red 1101661001 1101611001 1101621001 1100961001 1100911001 1100921001 24 Vb without LED green LED red 48 V- LED green LED red 48 Vb without LED green 1129660000 1181511001 1181521001 1100260000 1100210000 1100220000 1101761001 1101711001 1101721001 1100360000 1101811001 1101821001 1100410000 1100420000 1100560000 K 1101911001 without LED green LED red 1102061001 1102011001 115 V- without LED green LED red 1155161001 1155111001 1155121001 without LED green LED red 1102161001 1102111001 1102121001 1100760000 115 V~ without LED green LED red 1102261001 1102211001 1102221001 1100860000 230 V~ 240 V~ without LED green LED red 1128561001 1128511001 1128521001 60 V- G 1100620000 1155261001 1155211001 1155221001 K.31 SSB_K008-K059 22.10.2003 8:35 Uhr Seite K.32 RS-SERIES - RS 31 1 change-over contact Relay coupler * For high switching power * Suitable to switch inductive loads Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 12 14 A1 A2 A2 24 Vdc 11 12 14 A1 A2 11 A2 residual tensions Derating curve K A 16 8 0 0 10 20 30 40 50 60 70 C LED green/Yes/available -25 C...+40 C -40 C...+60 C 40C/93% rel. humidity without condensation CE EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 250V 6 kV 3mm III 2 No Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 2.5 / 0.5 / 4 70.0 / 25.0 / 58.0 Information Applications 250V/16A 1W 9ms/10ms AgCdO 3x10^7 switching cycles 0.1Hz mm2 mm Tension clamp connection SSB_K008-K059 22.10.2003 8:35 Uhr Seite K.33 RS-SERIES - RS 31 Relay coupler 1 change-over contact Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 24VDC 1CO 48VDC 1CO 115V DC 1CO 115VAC 1CO 24 Vdc +/- 10 % 48 Vdc +/- 10 % 115 Vdc + 5 / - 15% 115 Vac +5 %/ -15 % 8mA 40mA 1W 20mA 1W 8mA 1W 21.5V 43V 98V -/11.5mA -/13.5mA -/5.5mA 1VA 98V -/1.5mA Ordering data Complete module Screw connection Type Order No. Tension clamp connection RS 31 24VDC LD LP 1U 1128311001 RS 31 48VDC LD 1U 1150761001 LP RS 31 115VDC LD LP 1U RS 31 115VAC LD LP 1U 1150361001 1150461001 Type Order No. Ordering data Spare relay, pluggable Type Order No. Information Ordering data 230VAC 1CO Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 230 Vac + 5 / - 15% 4.5mA 1VA 195V -/2.2mA Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information RS 31 230VAC LD LP 1U 1128461001 K SSB_K008-K059 22.10.2003 8:35 Uhr Seite K.34 RS-SERIES - RS 32 Relay coupler 2 change-over contacts, DC input A 4 3 2 1 10 30 20 40 50 70 60 C 12 14 22 24 A1 Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 250V/4A 10V/100mA 13ms/10ms AgNi 0.15 gold flashed >30x10^6 switching cycles 0.1Hz LED red/No/available -25 C...+40 C -40 C...+60 C 40C/93% rel. humidity without condensation CE EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 250V 4 kV 3mm III 2 No Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 2.5 / 0.5 / 4 70.0 / 25.0 / 68.0 A2 A2 11 21 mm2 mm Tension clamp connection Information Ordering data K Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 12VDC 2CO 24VDC 2CO 48VDC 2CO 60VDC 2CO 12 Vdc +/- 10 % 24 Vdc +/- 10 % 48 Vdc +/- 10 % 60 Vdc +/- 10 % 50mA 0.6W 25mAdc 0.6W 12mAdc 0.6W 10mAdc 0.6W 11V 21.5V 43V 54V -/9.5mA -/5mA -/2mA -/1.5mA RS 32 12VDC LD LP 2U RS 32 24VDC LD LP 2U RS 32 48VDC LD LP 2U RS 32 60VDC LD LP 2U 9406021001 9406121001 9406321001 9406521001 Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information SSB_K008-K059 22.10.2003 8:35 Uhr Seite K.35 RS-SERIES - RS 32 Relay coupler 2 change over contacts, UC input Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards A 4 3 2 1 10 30 20 40 50 60 70 C 12 14 22 24 250V/4A 10V/100mA 13ms/10ms AgNi 0.15 gold flashed >30x10^6 switching cycles 0.1Hz LED red/No/not available -25 C...+40 C -40 C...+60 C 40C/93% rel. humidity without condensation CE EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 250V 4 kV 3mm III 2 No Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 2.5 / 0.5 / 4 70.0 / 25.0 / 68.0 A1 V A2 A2 11 Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 21 mm2 mm Tension clamp connection Information 24VUC 2CO 48VUC 2CO 115VUC 2CO 230VUC 2CO 24 Vuc +/- 10 % 28mAac 18mAdc 0.6W // 0.9VA 48 Vuc +/- 10 % 18mAac 12mAdc 0.6W // 0.9VA 115 Vuc + 5 / - 15% 5mA 5 mA 0.5W // 0.6VA 230 Vuc + 5 / - 15% 4.3mA 4.3mA 1W //1VA 21.5V -/2.5mA -/4.5mA 43V -/4.5mA -/2mA 98V -/1.5mA -/1mA 195V -/2mA -/1.2mA RS 32 24VUC LD LP 2U RS 32 48VUC LD LP 2U RS 32 115VUC LD LP 2U RS 32 230VUC LD LP 2U 9406221001 9406421001 9406621001 9406721001 Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information K SSB_K008-K059 22.10.2003 8:35 Uhr Seite K.36 RS-SERIES - RS 32 Relay coupler 2 change over contacts, multiple voltage input A 4 3 2 1 10 30 20 40 50 60 12 14 C 70 22 24 A1 Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 250V/4A 10V/100mA 13ms/10ms AgNi 0.15 gold flashed >30x10^6 switching cycles 0.1Hz LED red/No/not available -25 C...+40 C -40 C...+60 C 40C/93% rel. humidity without condensation CE EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 250V 4 kV 3mm III 2 No Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 2.5 / 0.5 / 4 70.0 / 25.0 / 68.0 A2 A2 11 21 Information Ordering data K Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 24-48VUC 2CO 115-230VUC 2CO 24 Vuc // 48 Vuc +/- 10 % 28mA / 22mA 18mA / 20mA 0.6W // 0.9VA 115 Vuc // 230 Vuc + 5 / - 15% 5.6mA/5.3mA 5.4mA/5mA 1W // 1VA 21.5V/43V -/3mA // -/4.5mA -/5mA // -/2mA 98V/195V -/1.5mA // -/2mA -/1mA // -/1.2mA RS 32 24-48VUC LD LP 2U RS 32 115-230VUC LD 2U 1122661001 1122761001 Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information mm2 mm Tension clamp connection SSB_K038-K039_GB 24.10.2003 16:17 Uhr Seite K.38 Relay coupler RS-SERIES - with RSM multiple interface with one change-over contact each RSM 4 R / RSM 4 RS RSM 8 R / RSM 8 RS RSM 16 R / RSM 16 RS * LEDs red, other colours on request 4 relays soldered or plugged 8 relays soldered or plugged 16 relays soldered or plugged * Mounting feet can also be mounted turned at an angle of 180 Technical data Rated data Input voltage Nominal consumption Nominal consumption Pull-in current Pull-in current soldered relay plugged relay soldered relay plugged relay soldered relay plugged relay soldered relay plugged relay Release current of relay (at 20C) Output voltage max. Continuous current Derating curve a = arranged on mounting rail in horizontal row without spacing b = arranged on mounting rail in horizontal row with 20 mm spacing 24 Vdc 0.45 W 0.75 W - - 12 mA 23 mA - - 24 Vac/dc - 0.45 W - 0.7 VA - 12 mA - 16.5 mA 48 Vdc - 0.75 W - - - 14 mA - - 115 Vac/dc - - - 0.6 VA - 5 mA - 6 mA 230 Vac - - - 1.2 VA - - - 4 mA 2 mA 250 V 6A 250 V 6A 250 V 6A 250 V 6A 250 V 3A 8 ms 7 ms 10 ms / 10 ms 15 ms / 20 ms 12 ms 11 ms 8 ms / 10 ms 5 ms / 8 ms 10 ms 10 ms 1.5 mA 1 mA Continuous current K Ambient temperature Typical switch-on times Pick-up delay ( ac / dc) Release delay ( ac / dc) Duration of bounce Switch-on current Switch-on power under ohmic load Min. switching power / switching current Contact material Service life mechanical 24 Vdc, 1A, ohmic load 230 Vac, 3A, ohmic load Storage temperature Ambient temperature Insulation coordination acc. to EN 50 178 Overvoltage category Pollution severity Dimensions Conductor cross-sectional area (screw connection) K.38 3 ms 8A 2000 VA 250 mW/10 mA AgNi 90/10, AgNi0,15, gold-flashed > 30 x 106 switching cycles > 5 x 105 switching cycles > 7 x 105 switching cycles -40C...+60C -25C...+50C III 2 0.5...2.5 mm2 SSB_K038-K039_GB 24.10.2003 16:17 Uhr Seite K.39 DC/AC/AC voltage RSM 16 RSM 8 RSM 4 2 2 2 1 1 1 3 3 3 4 4 4 11 14 12 21 24 22 31 34 32 41 44 42 8 8 N 16 DC voltage, switching minus (negative-switching) joint plus potential, RSM 16 RSM 8 minus connected up N N N RSM 4 81 84 82 161 164 162 1 1 1 2 2 2 3 3 3 4 4 4 11 14 12 21 24 22 31 34 32 41 44 42 DC voltage, positive-switching joint minus potential, plus connected up RSM 16 1 RSM 8 1 RSM 4 1 2 2 2 3 3 3 4 4 4 11 14 12 21 24 22 31 34 32 41 44 42 8 8 Relay coupler RS-SERIES - with RSM multiple interface 16 19/-20/+ 9/-10/+ - + 81 84 82 161 164 162 8 8 16 19/+20/9/+10/+ - 81 84 82 161 164 162 Order data Connection technology Input Flat band connection Output Screw connection Input Screw connection Output Multiple plug with locking acc. to DIN 41651/part 1 and 2 * Plugged relay Screw connection and multiple plug acc. to IEC 603-1/DIN 41651 * Relay soldered Multiple plug acc. to IEC 603-1/DIN 41651 Input voltage 24 Vdc, switching minus 4 relays RSM 4 R/RS (B = 75 mm) 8 relays RSM 8 R/RS (B = 145 mm) 1100061001 16 relays RSM 16 R/RS (B = 285 mm) 1100161001 Relay soldered 24 Vdc, switching plus Relay pluggable Relay soldered 11133610011) 1112361001 11135610011) 1107761001 11137610011) 1107861001 24 Vdc, switching minus Relay pluggable Relay soldered 11134610011) 11136610011) 1112661001 11138610011) 24 Vac/dc Relay pluggable 1173461001 1173561001 1173661001 48 Vdc, switching plus Relay pluggable 1113961001 1114161001 1114361001 115 Vac/dc Relay pluggable 1114561001 1114661001 1114761001 230 Vac Relay pluggable 1114861001 1114961001 1115061001 Screw connection 1) approved by Germanisch Lloyd Spare relays (for plugging) For RSM ... R/RS, 24 V Input voltage 24 Vdc Contact material AgNi 90/10 AgNi 90/10 Remarks RT 314024 with clip RT 314024 without clip Order no. 8630780000 4058480000 For RSM ... R/RS, 48 V 48 Vdc AgNi 90/10 AgNi 90/10 RT 314048 with clip RT 314048 without clip 8630790000 4058740000 For RSM ... R/RS, 115 V and 230 V 115 Vdc AgNi 90/10 AgNi 90/10 RT 314110 with clip RT 314110 without clip 8630770000 4058500000 K.39 K SSB_K008-K059 22.10.2003 8:54 Uhr Seite K.40 MCZ-Series Relay coupler MiniConditioner MCZ R Module can be used as an universal interface between control and actuator for switching small and medium loads * The pluggable cross-connection in input and output minimizes the effort to wire * Width 6 mm, low height 4 3 2 0V 11 14 12 5 + 24 V DC-Input 4 3 2 0V 11 12 1 14 5 24 Vuc / 230 Vac 4 24 V 2 0V 3 11 12 14 5 1 120 V 120 Vac Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards 400V/6A 12V/100mA 4.5ms/10ms AgSnO2 20x10^6 switching cycles 0.1Hz LED green/Yes/available -25 C...+50 C -40 C...+60 C 40C/93% rel. humidity without condensation CE, UL, CSA, GL EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 300 V 6 kV => 5.5mm III 2 Yes Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection mm2 mm Information Applications Limit diagram Derating curve rowed without clearances on the mounting rail rowed with 20 mm spacing on the mounting rail U/Vdc / IL/A /A 300 6 K 5 prohibited area 200 4 3 100 2 25 1 1 2 3 4 5 6 IL/Adc 20 25 30 35 40 45 50 C C Tension clamp connection 1.5 / 0.5 / 2.5 91.0 / 6.0 / 63.2 SSB_K008-K059 22.10.2003 8:54 Uhr Seite K.41 MCZ-Series Relay coupler MiniConditioner MCZ R Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 24VDC 1CO 24VUC 1CO 24VDC 1CO AU 60VDC 1CO 24 Vdc +/- 20 % 24 Vdc +/- 20 % 60 Vdc +/- 20 % 6.3mA 156mW 3mA 180mW 12V...19V/4V...5.5V 24 Vuc +/- 10 % 10.8mA 6.1mA 160mVA / 150mW approx.17V/approx.7V approx.19V/approx.4V 12V...19V/4V...5.5V approx.38V/approx.14V 5.7mA 9mA/5mA 5.7mA 2.7mA MCZ R 24VDC MCZ R 24VUC MCZ R 24VDC MCZ R 60VDC 8365980000 8390590000 8442960000 8470380000 110VDC 1CO 120VAC 1CO 230VAC 1CO 110 Vdc +/- 10 % 120 Vac -15 %/ +10 % 7mA 230 Vac +/- 10 % 9.5mA 0.85VA approx.7V/approx.22V 2.1VA approx.115V/approx.60V 4mA/1.3mA 5mA/2.5mA MCZ R 110VDC MCZ R 120VAC MCZ R 230VAC 8467470000 8420880000 8237710000 6.3mA 156mW Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information Ordering data Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 2.85mA 340mW approx.68V/approx.19V 1.6mA/0.4mA Ordering data Complete module Screw connection Type Order No. Tension clamp connection Type Order No. Ordering data Spare relay, pluggable Type Order No. Information K SSB_K008-K059 22.10.2003 8:54 Uhr Seite K.42 DK-SERIES Relay coupler 1 NO contact, input bottom Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards Input Output 1 3 A1 + 13 2 4 14 A2 - Ordering data K Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil 100V/500mA 1 V / 1 mA typ.0.7...2.5ms/0.2...2ms RH/RU 10^9 switching cycles 200Hz LED green/Yes/available -25 C...+40 C -40 C...+60 C 40C/93% rel. humidity without condensation CE EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 150 V 1.5 kV =>3mm III 2 No Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 4 / 0.5 / 4 77.0 / 6.0 / 62.0 Information mm2 mm Tension clamp connection AP DK4: 0687560000 5 VDC 1A 12VDC 1A 24VUC 1A 24VDC 1A 5 Vdc +/- 5 % 12 Vdc +/- 10 % 24 Vdc +/- 20 % 12.5mA 65mW 12mA 144mW 4.4V 9V 11.8mA 10mA 12 Vuc +/- 10 % 15mA 12mA 144mW 12V 11V 6.3mA 3.8mA DKR 32 5VDC 1A DKR 32 24VUC 1A DKR 32 24VDC 1A 8019600000 8008110000 8016620000 9.3mA 225mW 11V 7.5mA Ordering data For TS 32 Type Order No. For TS 35 Type Order No. Ordering data Type Order No. Information DKR 35 5VDC 1A DKR 35 12VDC 1A DKR 35 24VUC 1A DKR 35 24VDC 1A 8019610000 8171100000 8016610000 8008170000 SSB_K008-K059 22.10.2003 8:54 Uhr Seite K.43 DK-SERIES Relay coupler 1 NO contact, input top Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards Input Output A1 + 13 3 1 100V/500 1 V / 1 mA typ.0.7...2.5ms/0.2...2ms RH/RU 10^9 switching cycles 25Hz LED green/Yes/available -25 C...+40 C -40 C...+60 C 40C/93% rel. humidity without condensation CE EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 150 V 1.5 kV =>3mm III 2 No Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 4 / 0.5 / 4 77.0 / 6.0 / 62.0 24 V= 3 4 A2 - 14 Ordering data Information 9.3mA 225mW 11V 3.75mA Type Order No. Type Order No. Ordering data Type Order No. Information AP DK4: 0687560000 24 Vdc +/- 20 % Ordering data For TS 35 Tension clamp connection 24 VDC 1A Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil For TS 32 mm2 mm DKR 35 24VDC 1A 8215620000 K SSB_K008-K059 22.10.2003 8:54 Uhr Seite K.44 DK-SERIES Relay coupler 1 change-over contact, input bottom Output Max. switching voltage AC/Continuous current Min. switching power Response time / Release time Contact base material Mechanical endurance Max. switching frequency at rated load Rated data Status indicator/Free wheel diode/Reverse volt. prot. Ambient temp., fitted w. distance Storage temperature Climate Approvals Insulation coordinates (EN 50 178) Standards Ein/In Aus/Out 3 1 A1 + 5 14 12 250V/6A 10 V / 100 mA 6ms/15ms ac;8ms dc AgSnO2 2x10^7 switching cycles 20 LED green/Yes/not available -40C...+60C -40 C...+60 C 40C/93% rel. humidity without condensation EN 50178 Rated voltage Impulse withstand voltage Creepage and clearance path input - output Overvoltage category Pollution severity Secure separation acc. to VDE 0106 Part 101 300 V 4 kV =>8mm III 2 No Dimensions Clamping range (rating- / min. / max.) Length x width x height Screw connection 4 / 0.5 / 4 77.0 / 6.0 / 62.0 24V= 4 11 2 6 A2 - Ordering data K Input Rated voltage Rated current AC Rated current DC Power rating Oper.-/drop-out volt. AC-coil Oper.-/drop-out volt. DC-coil Pull-in curr./release curr. AC-coil Pull-in curr./release curr. DC-coil Information mm2 mm End plate 24VUC 1CO 24VDC 1CO 24VUC 1CO 24 Vuc +/- 20 % 9mA 7mA 220mVA/180mW 18V 19V 7mA 5.5mA 24 Vdc +/- 20 % 9mA 24 Vuc +/- 20 % 20mA 16mA 480mW /400mW 18V 18V 12.8mA 11.5mA DKR DK5 24VUC 1U DKR 35 24VDC 1U DKR 35 24VUC 1U 9454910000 8181980000 8181970000 11.5mA 384mW 19V Ordering data For TS 32 Type Order No. For TS 35 Type Order No. Ordering data Type Order No. Information DKR DK5 24VUC 1U 9454910000 Tension clamp connection SSB_K046-K047_GB 10.10.2003 9:44 Uhr Seite K.46 EG SERIES Relay coupler 1 NCC, 1 NOC, 1 change-over contact * Also with hard gold-plated contacts * With combination foot for TS 32, TS 32 and TS 35 (clip-in base for plug-in) change-over contacts * 10 mm wide * Screw connection Technical data Output Max. switching voltage AC / constant current Min. switching power hard gold-plated contacts Response time/release time Contact base material hard gold-plated contacts Mechanical service life Max. switching frequency at rated load Nominal data Status indicator/recovery diode Ambient temperature arranged in horizontal row with spacing Lagertemperatur Insulation coordination (EN 50 178) Standards Main-line wiring diagram A1 A2 Constant current Main-line wiring diagram Rated voltage Rated impuls voltage Creepage and clearance path input-output Overvoltage category Pollution severity Protective separation acc. to VDE 0106 part 101 a = arranged on mounting rail in horizontal row without spacing b = arranged on mounting rail in horizontal row with 20 mm spacing Remarks K K.46 LED green / yes -25 C ... +60 C -40 C ... +60 C EN 50178 300 V 8 kV 8 mm III 2 DIN VDE 0106 Ambient temperature Clamping range (nom./min/max) Length x width x height 250 V / 5 A 100 mW / 10 mA 40 W 8 ms / 6 ms AgNi 0.15 gold-flashed AgNi 0.15 / 5 Au > 15 x 106 switching cycles 0,1 Hz mm2 mm 1 NOC, 1 NCC 1.5 x 0.5 x 1.5 44.0 x 10.0 x 96.0 1 change-over contact 1.5 x 0.5 x 1.5 95.0 x 10.0 x 93.0 SSB_K046-K047_GB 10.10.2003 9:44 Uhr Seite K.47 EG SERIES Relay coupler 1 NOC, 1 NCC, 1 change-over contact Order data 12 Vac/dc 24 Vdc 24 Vac/dc 115Vac/dc Input Rated voltage 12 Vac/dc, +15%, -10 % 24 Vdc +15 % -10 % 24 Vac/dc +15 % -10 % 115 Vac/dc + 15 % -10 % Nominal power 320 mW +20% -10% 280 mW +20% -10% 280 mW +20% -10% 330 mW +15% -10% 120 mA 12 mA 240 mA 160 mA Switch-on current, max. Order data with combination foot 1 NOC Type Order no. 1 NCC Type Order no. EGR EG 7 EGR EG 7 EGR EG7 EGR EG7 8092310000 8216520000 8092340000 8092430000 EGR EG 7 EGR EG 7 EGR EG7 EGR EG7 8092320000 8216530000 8092350000 8092440000 Order data, pluggable (order clip-in base separately) 1 change-over contact Type Order no. 1 clip-in base Type Order no.. Order data RST EG 7 RST EG 7 RST EG 7 RST EG 7 8216550000 8216570000 8216580000 8216610000 RS EG 7 RS EG 7 RS EG 7 RS EG 7 8193830000 8193830000 8193830000 8193830000 24 Vdc 230 Vac 230 Vac Contacts hard gold-plated Input Rated voltage 230 Vac +15 % -10 % 24 Vdc +15% -10% 230 Vac +15% -10% Nominal power 280 mW +15% -10% 280 mW +20% -10% 280 mW +15% -10% 185 mA 12 mA 185 mA Switch-on current, max. Order data with combination foot 1 NOC Type Order no. 1 NCC Type Order no. EGR EG 7 EGR EG 7 EGR EG 7 8092460000 8147120000 8178200000 EGR EG 7 EGR EG 7 8092470000 8147140000 Order data, pluggable (order clip-in base separately) 1 change-over contact Type RST EG 7 RST EG 7 RST EG 7 Order no. 8216620000 8216560000 8216630000 RS EG 7 RS EG 7 RS EG 7 Order no.. 8193830000 8193830000 8193830000 1 clip-in baseType K.47 K