MPB125 Multiple-Output AC-DC Series Data Sheet
OCT 24, 2005 revised to JUN 05, 2006 Page 1 of 9 www.power-one.com
Multiple Output Model Selection
MODEL
OUTPUT MAXIMUM OUTPUT TOTAL RIPPLE & NOISE 1
REGULATION RANGE
VOLTAGE CURRENT (AMPS), REGULATION % pk-pk
(VOLTS) 130 LFM %
MPB125-2003 2+3.3V 30A ±3% 1% 3.20V to 3.40V
+12V 0.5A ±5% 1% 11.80V to 12.60V
MPB125-2005 3, 4 +5V 25A ±3% 1% 4.85V to 5.15V
+12V 0.5A ±5% 1% 10.80V to 12.60V
MPB125-2012 3, 4, 5 +12V 10.5A ±3% 1% 11.64V to 12.36V
12V 0.5A ±5% 1% 11.40V to 12.60V
MPB125-2015 3, 4, 5 +15V 8.3A ±3% 1% 14.54V to 15.45V
12V 0.5A ±5% 1% 11.40V to 12.60V
MPB125-2024 3, 4, 5 +24V 5.2A ±3% 1% 23.28V to 24.72V
12V 0.5A ±5% 1% 11.40V to 12.60V
MPB125-2048 3, 4, 5 +48V 2.6A ±3% 1% 46.56V to 49.44V
12V 0.5A ±5% 1% 11.40V to 12.60V
MPB125-3000 6+5V 16.5A ±4% 1% 84.85V to 5.25V
+12V 5A/9Apk ±5% 1% 11.40V to 12.60V
-12V 0.5A ±5% 1% -11.40V to -12.60V
MPB125-4250 6
+2.5V 12A 7±3% 2% 2.42V to 2.58V
+5V 15A 7±4% 1% 84.85V to 5.25V
+12V 5A/9Apk ±5% 1% 11.40V to 12.60V
-12V 0.5A ±5% 1% -11.40V to -12.60V
MPB125-4350 6
+3.3V 10A 7±3% 1.5% 3.20V to 3.40V
+5V 15A 7±4% 1% 84.85V to 5.25V
+12V 5A/9Apk ±5% 1% 11.40V to 12.60V
-12V 0.5A ±5% 1% -11.40V to -12.60V
NOTES: 1Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2For MPB125-2003 and -2003D, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1.
V1 current can be as high as 25A with a minimum airflow of 5 CFM.
3Maximum forced-air output power is 125 watts with 5 CFM airflow.
4Maximum convection output power is 70 watts.
5V2 is isolated from V1 and can be used as a negative or positive output.
612V output’s peak load maximum duration is 30 seconds. Average current must not exceed 5A.
7Maximum power of 80 watts from V1 + V2 with 5 CFM forced-air cooling. See Application Note #M3 for details.
8For loads less than 10 watts on V1 + V2 + V3, ripple and noise on the +5V output is Max. 2% peak-to-peak.
RoHS lead free and lead-solder-exempt products are available
High power density in an industry-standard 3" x 5" footprint
Power Factor Correction (PFC) meets EN61000-3-2
Main output remote sense
Power Good signals
CE marked to Low Voltage Directive
Input transient & ESD compliance to
EN61000-4-2/-3/-4/-5
MTBF In excess of 1M hours based upon field data
Optional remote on/off with 5V standby
(See page 4 for ordering information)
Features
The MPB125 Series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC)
to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations.
Dual output units deliver a regulated main output plus a second 12V output for fans or other system functions. Multiple output models
provide tightly regulated DC power in a variety of configurations. The MPB125 is rated for convection as well as forced-air cooling.
Full output power is available with as few as 5 Cubic Feet per Minute (CFM) forced-air cooling with the exception of the MPB125-
2003 and -2003D which need only 10 CFM for full power. Optional remote on/off with st andby power is also provided (see Options).
The MPB125 product line is approved to the latest international regulatory standards, and displays the CE Mark.
Description
MPB125 Multiple-Output AC-DC Series Data Sheet
OCT 24, 2005 revised to JUN 05, 2006 Page 2 of 9 www.power-one.com
Interface Signals and Internal Protection
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection V1 of dual and triple output models; V1 & V2 outputs of 4-output models.
MPB125-2003 and -2003D 3.67 4.80
MPB125-4250 (V1) 3.20 4.00
MPB125-4350 (V1) 3.76 4.80
VDC
5V Output of MPB125-2005 and -2005D, MPB125-3000, or MPB125-4X50 5.74 7.00
MPB125-2012 13.5 16.5
MPB125-2015 17.0 19.0
MPB125-2024 26.9 31.1
MPB125-2048 57.6 62.4
Overload Protection Fully protected against output short circuit or overload. Automatic recovery upon
removal of overload condition. MPB125-2003, -2003D -2005, and -2005D latch OFF if
overload occurs on V1 which requires an AC reset.
Remote Sense (Note 2) Total (+sense and -sense) voltage compensation for cable losses on
Dual Output Models dual output models. 500 mV
Remote Sense (Note 2) On models MPB125-4250 and -4350 remote sense is provided on
Triple & Quad Output Models the 2.5 and 3.3V outputs, respectively.
MPB125-3000 does not have positive remote sense.
Total voltage compensation for cable losses on +Sense. 200 mV
Total voltage compensation for cable losses on -Sense. 100
NOTES: 1) For MPB125-2003, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1. V1 current can be as high as 25A with a
minimum airflow of 5 CFM.
2) -Sense must be connected to output common or load common for proper power supply operation.
Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage- AC Continuous input range. 90 264 VAC
Input Frequency AC Input. 47 63 Hz
Brownout Protection Lowest AC input voltage that regulation is maintained with full rated loads. 90 VAC
Hold-up Time Over full AC input voltage range at full rated load. 17 ms
Input Current 90 VAC at full rated load. 1.8 ARMS
Input Protection Non-user serviceable internally located AC input line fuse, 250 VAC, 3.15A.
Inrush Surge Current Internally limited by thermistor, 110VAC: 23 APK
one cycle, 25° C. 220VAC: 46
Power Factor Circuitry Active PFC meets requirements of EN61000-3-2.
Operating Frequency Switching frequency of main transformer. 45 kHz
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Full Load, 230VAC. Varies with distribution of loads among outputs. 73 80 85 %
(Minimum efficiency reflects that of MPB125-2003D and -2005D models.)
Minimum Loads V1 + V2 + V3 for MPB125-4XXX and -3000. 5 Watts
V1 for MPB125-2XXX for full regulation on V2. All models operate 5
at no load without any damage and meet all specs on V1 above 0 amps.
Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Chart
Output Power (Note 1) At 5 CFM forced-air cooling. See Application Note #M3 for details. 125 Watts
Convection: Consult Factory
Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on. 10 %
Regulation Varies by output. Total regulation includes: line changes from 85-132 VAC See Model Selection Chart
or 170-264 VAC, changes in load starting at 20% load and changing to 100% load.
Transient Response Maximum deviation due to a 25% load change with unit at 75% load.
All models except MPB125-2005 and -2005D. 3 %
Model MPB125-2005 and -2005D. 5
Turn-on Delay Time required for initial output voltage stabilization. 0.2 1.5 Sec
Turn-on Rise Time Time required for output voltage to rise from 10% to 90% except for MPB125-2005 0.2 20 ms
and -2005D.
MPB125-2005 and MPB125-2005D. 1 100 ms
MPB125 Multiple-Output AC-DC Series Data Sheet
OCT 24, 2005 revised to JUN 05, 2006 Page 3 of 9 www.power-one.com
Safety, Regulatory, and EMI Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals UL60950-1.
CSA 22.2 No. 60950-1.
EN60950 (TÜV).
IEC60950-1.
Dielectric Withstand Voltage AC to chassis. 1500 VAC
Input to output. 3000 VDC
Electromagnetic Interference EN55022 Conducted. B Class
ESD Susceptibility Per EN61000-4-2, Level 4 8 kV
Flicker Per EN61000-3-3.
Radiated Susceptibility Per EN61000-4-3. 3 V/m
EFT/Burst Per EN61000-4-4. 1 kV
Input Transient Protection Per EN61000-4-5, Level 3, 2 kV (Line-to-Gnd) minimum, 1 kV (Line-to-Line) minimum.
RF Immunity Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sinewave) 3 V/m
Magnetic Fields Per EN61000-4-8. 1 A/m
Voltage Dips Per EN61000-4-11.
Insulation Resistance Input to output. 10 M
Leakage Current Per EN60950 (264 VAC) 1.0 mA
Interface Signals and Internal Protection (Cont.)
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Power Good Signal AC/DC indicator - This signal indicates the status of the AC input or DC outputs.
When there is sufficient AC voltage and the outputs are operating normally, an
open collector signal is provided.
Turn-On delay time from application of AC: 50 500
Warning time before outputs go out of regulation: 5 ms
Warning time before outputs deviate ±10% from the nominal value: 15
Sync Current 20 mA
Pull-up Voltage 30 V
Power Supply OK Signal Provided on dual-output models. Open collector signal intended to drive an LED.
Closed collector occurs when the Power Good Signal is in its open collector state.
Sync Current 20 mA
Pull-up Voltage 30 V
Thermal Shutdown Protected against overtemperature conditions.
Unit recovers when overtemperature condition is removed.
Current Share Provided on dual-output models. Up to 4 units can be connected in parallel.
There are some limits for parallel operation. See MPB125 Applications Note.
N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation.
An external diode is required on MPB125-2003 and MPB125-2005 models for
redundancy on both V1 and V2, or when ordering, you can specify MPB125-2003D or
-2005D which have an internal isolation diode.
Isolation Diode Internal isolation diode is provided on V1 for all dual-output models except the
MPB125-2003 and MPB125-2005. Specify MPB125-2003D or MPB125-2005D,
respectively, if an internal isolation diode is required for these models.
MPB125 Multiple-Output AC-DC Series Data Sheet
OCT 24, 2005 revised to JUN 05, 2006 Page 4 of 9 www.power-one.com
Environmental Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating 10K ASL Feet
Non-Operating 50K
Operating Temperature Derate linearly from 50 to 70°C to 50% power at 70°C. At 100% load: 0 50 °C
MPB125 models will operate at -20°C, but will not meet all specifications.
Storage Temperature -40 85 °C
Forced-Air Cooling 1Forced-air cooling of 5 CFM is required for full output power except for
MPB125-2003 and -2003D. Air velocity is measured with power supply mounted on
0.375" (9.5mm) standoffs. Airflow direction is from the input section to
the output section. See Application Note #M3 for details.
Temperature Coefficient Included in total regulation of outputs.
Relative Humidity Non-Condensing. 5 95 %RH
Shock Operating: 11 ±3ms, 3 axes, Half Sine. 15 Gpk
Non-operating: 11 ±3ms, 3 axes, Half Sine. 40
Vibration Operating: Random vibration, 5-500 Hz, 10 minutes each axis. 2.4 GRMS
Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis. 6.0 GRMS
Options
DESCRIPTION NOTES
Remote On/Off Remote On/Off is a TTL-comatible signal. A logic “high” or open circuit turns the unit on. Reverse inhibit logic can be achieved
Standby Output by changing the position of the J6 connector. A logic “low” inhibits all outputs except the 5V standby. At remote off, the Power
(Option R) Good signal will warn the host equipment 2 milliseconds before the main output goes out of regulation. The rating of the
standby output is +5V @ 0.2 Amps. Total regulation is ±5 %. Maximum noise and ripple is 50 mV peak-to-peak @ a 20 MHz
bandwidth.
NOTE: The addition of Option “R” increases the supply width from 3.0 to 3.8 inches. Consult factory for availability.
NOTES: 1 For MPB125-2003 and -2003D, a minimum airflow of 10 CFM is required to provide the maximum current of 30A on V1. V1 current can be as high as
25A with a minimum airflow of 5 CFM.
Ordering Information:
OPTIONS SUFFIXES TO ADD TO PART NUMBER
RoHS lead solder exempt 1No RoHS suffix character required.
RoHS compliant for all 6 substances Add “G” as the last character of the part number.
1 The solder exemption refers to all the restricted materials except lead in solder.
MPB125 Multiple-Output AC-DC Series Data Sheet
OCT 24, 2005 revised to JUN 05, 2006 Page 5 of 9 www.power-one.com
MPB125
-2012
-2015
-2024
-2048
J1 Housing 09-50-8031
Pins 08-52-0113
J2 Housing 09-50-8061
Pins 08-52-0113
J3 Housing 22-01-3067
Pins 08-50-0114
J4 Housing 22-01-3027
Pins 08-50-0114
J 1 - A C INPUT CONNECTOR
J 2 - V 1 DC OUTPUT
CONNECTOR
FASTENER
CLEARANCE
AREA (4 PL)
PIN #1
SAFETY GROUND
CONNECTION POINT
PRINTED CIRCUIT BOARD
SCREWS SHOWN
FOR REFERENCE
ONLY
TOP VIEW
SIDE VIEW
WEIGHT: 0.63 lb. (0.3 kg)
Pin 1 NEUTRAL
Pin 2 NO PIN
Pin 3 LINE
Pin 1 +12V
Pin 2 +12V RTN
J4 -
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
+12V
+12V
+12V
RTN
RTN
RTN
+24V
+24V
+24V
RTN
RTN
RTN
+48V
+48V
+48V
RTN
RTN
RTN
J2 - MPB125
-2012 -2024
+15V
+15V
+15V
RTN
RTN
RTN
-2015 -2048
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
RTN
- SENSE
+ SENSE
CURRENT SHARE
POWER GOOD
POWER SUPPLY OK
J3 -
J3- SIGNAL
CONNECTOR
PIN #1
PIN #1
PIN #1
J4- V2 DC OUTPUT
CONNECTOR
5.00"
(127.0)
4.55"
(115.57)
2.78"
(70.6)
3.00"
(76.2)
2.56"
(65.02)
Ø 0.16" (4 PL)
(4.06)
1.25"
(31.75)
1.00"
(25.4)
0.06"
(1.5)
0.19"
(4.8)
END VIEW
Mechanical Drawing (-2012, -2015, -2024, & -2048 Models)
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB125 Multiple-Output AC-DC Series Data Sheet
OCT 24, 2005 revised to JUN 05, 2006 Page 6 of 9 www.power-one.com
MPB125
-2005
J1 Housing 09-50-8031
Pins 08-52-0113
J2 Housing 09-50-8103
Pins 08-52-0113
J3 Housing 22-01-3057
Pins 08-50-0114
J4 Housing 22-01-3027
Pins 08-50-0114
J1 - AC INPUT CONNECTOR
J2 - V1 DC OUTPUT
CONNECTOR
FASTENER
CLEARANCE
AREA (4 PL)
PIN #1
SAFETY GROUND
CONNECTION POINT
PRINTED CIRCUIT BOARD
SCREWS SHOWN
FOR REFERENCE
ONLY
TOP VIEW
SIDE VIEW
WEIGHT: 0.63 lb. (0.3 kg)
Pin 1 NEUTRAL
Pin 2 NO PIN
Pin 3 LINE
Pin 1 +12V
Pin 2 +12V RTN
J4 -
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
J2 -
Pin 7
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
SHARE
- SENSE
+ SENSE
POWER SUPPLY OK
POWER GOOD
J3 -
J3- SIGNAL
CONNECTOR
PIN #1
PIN #1
PIN #1
J4- V2 DC OUTPUT
CONNECTOR
5.00"
(127.0)
4.55"
(115.57)
2.78"
(70.6)
3.00"
(76.2)
2.56"
(65.02)
Ø 0.16" (4 PL)
(4.06)
1.25"
(31.75)
1.00"
(25.4)
0.06"
(1.5)
0.19"
(4.8)
Pin 8
Pin 9
Pin 10
+5V
+5V
+5V
+5V
+5V
RTN
MPB125
-2005
RTN
RTN
RTN
RTN
+3.3V
+3.3V
+
3.3
V
+
3.3
V
+
3.3
V
RTN
MPB125
-2003
RTN
RTN
RTN
RTN
END VIEW
Mechanical Drawing (-2003, -2003D, -2005, and -2005D Models)
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB125 Multiple-Output AC-DC Series Data Sheet
OCT 24, 2005 revised to JUN 05, 2006 Page 7 of 9 www.power-one.com
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
5.00"
(127.0)
4.55"
(115.57)
2.78"
(70.6)
J1- INPUT
CONNECTOR J2 - DC OUTPUT
CONNECTOR
J3
FASTENER
CLEARANCE
AREA (4 PL)
PIN #1
PIN #1
PIN #1
SAFETY GROUND
CONNECTION POINT
PRINTED CIRCUIT BOARD
SCREWS SHOWN
FOR REFERENCE
ONLY
2.56"
(65.02)
1.25"
(31.75)
0.19"
(4.8)
0.06"
(1.5)
1.00"
(25.4)
3.00"
(76.2)
Ø 0.16" (4 PL)
(4.06)
TOP VIEW
SIDE VIEW
J1 - AC INPUT CONNECTOR
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
Pin 11
Pin 12
Pin 13
Pin 14
-12V
+12V
N/C
N/C
N/C
RTN
RTN
RTN
RTN
RTN
+5V
+5V
+5V
+5V
-12V
+12V
+2.5V
+2.5V
+2.5V
RTN
RTN
RTN
RTN
RTN
+5V
+5V
+5V
+5V
-12V
+12V
+3.3V
+3.3V
+3.3V
RTN
RTN
RTN
RTN
RTN
+5V
+5V
+5V
+5V
Pin 1 -SENSE
Pin 2 +SENSE
Pin 3 POWER GOOD
J2 -
J3 -
Pin 1 NEUTRAL
Pin 2 NO PIN
Pin 3 LINE
MPB125
-3000
MPB125
-4250
MPB125
-4350
WEIGHT: 0.63 lb. (0.3 kg)
END VIEW
Mechanical Drawing (-3000, -4250, & -4350 Models)
MPB125
-3000
-4250
-4350
J1 Housing 09-50-8033
Pins 08-52-0113
J2 Housing 09-50-8143
Pins 08-52-0113
J3 Housing 22-01-3037
Pins 08-50-0114
MPB125 Multiple-Output AC-DC Series Data Sheet
OCT 24, 2005 revised to JUN 05, 2006 Page 8 of 9 www.power-one.com
Mechanical Drawing (-2012R, -2015R, -2024R, & -2048R Models)
MPB125 Series “R” Option
J1 - AC INPUT CONNECTOR
J2 - V1 DC OUTPUT
CONNECTOR
FASTENER
CLEARANCE
AREA (4 PL)
PIN #1
SAFETY GROUND
CONNECTION POINT
PRINTED CIRCUIT BOARD
SCREWS SHOWN
FOR REFERENCE
ONLY
TOP VIEW
SIDE VIEW
WEIGHT: 0.63 lb. (0.3 kg)
Pin 1 NEUTRAL
Pin 2 NO PIN
Pin 3 LINE
Pin 1 +12V
Pin 2 +12V RTN
J4 -
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
+12V
+12V
+12V
RTN
RTN
RTN
+24V
+24V
+24V
RTN
RTN
RTN
+48V
+48V
+48V
RTN
RTN
RTN
J2 - MPB125
-2012 -2024
+15V
+15V
+15V
RTN
RTN
RTN
-2015 -2048
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
RTN
- SENSE
+ SENSE
CURRENT SHARE
POWER GOOD
POWER SUPPLY OK
J3 -
J3- SIGNAL
CONNECTOR
PIN #1
PIN #1
PIN #1
J4- V2 DC OUTPUT
CONNECTOR
5.00"
(127.0)
4.55"
(115.57)
2.78"
(70.6)
0.80"
(20.3)
1.025"
(26.04)
3.80"
(97)
2.56"
(65.02)
Ø 0.16" (6 PL)
(4.06)
1.25"
(31.75)
1.00"
(25.4)
0.06"
(1.5)
0.19"
(4.8)
J5
PIN #1
Pin 1
Pin 2
Pin 3
RTN
REMOTE
ON/OFF
+5V
STANDBY
J5 -
END VIEW
RECOMMENDED
MOUNTING
OPTIONAL
MOUNTING
J6
POSITION FOR
STANDARD
INHIBIT LOGIC
POSITION FOR
REVERSE
INHIBIT LOGIC
MPB125
-2012
-2015
-2024
-2048
J1 Housing 09-50-8033
Pins 08-52-0113
J2 Housing 09-50-8063
Pins 08-52-0113
J3 Housing 22-01-3067
Pins 08-50-0114
J4 Housing 22-01-3027
Pins 08-50-0114
J5 Housing 22-01-3037
Pins 08-50-0114
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
MPB125 Multiple-Output AC-DC Series Data Sheet
OCT 24, 2005 revised to JUN 05, 2006 Page 9 of 9 www.power-one.com
MPB125
-3000R
-4250R
-4350R
J1 Housing 09-50-8033
Pins 08-52-0113
J2 Housing 09-50-8143
Pins 08-52-0113
J3 Housing 22-01-3037
Pins 08-50-0114
J5 Housing 22-01-3037
Pins 08-50-0114
Mechanical Drawing (-3000R, -4250R, & -4350R Models)
MPB125 Series “R” Option
5.00"
(127.0)
4.55"
(115.57)
2.78"
(70.6)
3.80"
(97)
J1- INPUT
CONNECTOR
J5
J2 - DC OUTPUT
CONNECTOR
J3
FASTENER
CLEARANCE
AREA (6 PL)
PIN #1
PIN #1
PIN #1
SAFETY GROUND
CONNECTION POINT SCREWS SHOWN
FOR REFERENCE
ONLY
2.56"
(65.02)
1.025"
(26.04)
0.80"
(20.3)
0.06"
(1.5)
Ø 0.16" (6 PL)
(4.06)
TOP VIEW
PRINTED CIRCUIT BOARD
1.25"
(31.75)
0.19"
(4.8)
1.00"
(25.4)
SIDE VIEW
J1 - AC INPUT CONNECTOR
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10
Pin 11
Pin 12
Pin 13
Pin 14
-12V
+12V
N/C
N/C
N/C
RTN
RTN
RTN
RTN
RTN
+5V
+5V
+5V
+5V
-12V
+12V
+2.5V
+2.5V
+2.5V
RTN
RTN
RTN
RTN
RTN
+5V
+5V
+5V
+5V
-12V
+12V
+3.3V
+3.3V
+3.3V
RTN
RTN
RTN
RTN
RTN
+5V
+5V
+5V
+5V
J2 -
Pin 1 -SENSE
Pin 2 +SENSE
Pin 3 POWER GOOD
J3 -
Pin 1
Pin 2
Pin 3
RTN
REMOTE
ON/OFF
+5V
STANDBY
J5 -
Pin 1 NEUTRAL
Pin 2 NO PIN
Pin 3 LINE
MPB125
-3000
MPB125
-4250
MPB125
-4350
WEIGHT: 0.63 lb. (0.3 kg)
END VIEW
RECOMMENDED
MOUNTING
OPTIONAL
MOUNTING
J6
POSITION FOR
STANDARD
INHIBIT LOGIC
POSITION FOR
REVERSE
INHIBIT LOGIC
PIN #1
Mating Connectors
NOTE: Part numbers are MOLEX; equivalents are acceptable.
NUCLEAR AND MEDICALAPPLICA TIONS - Power-One product s are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.