3www.pericom.com PI6C490098 RevB 1/14/2016
PI6C490098
1:3 25MHz Clock Buer
Power Requirements(Over operating free-air temperature range)
Storage Temperature .......................................................... –65°C to +150°C
Supply Voltage to Ground Potential, VDD ........................–0.5V to +4.6V
Note: Stresses greater than those listed under MAXIMUM
RATINGS may cause permanent damage to the device. is is a
stress rating only and functional operation of the device at these
or any other conditions above those indicated in the operational
sections of this specication is not implied. Exposure to absolute
maximum rating conditions for extended periods may aect
reliability.
Maximum Ratings
(Above which useful life may be impaired. For user guidelines, not tested.)
Symbol Parameter Min. Ty p. Max. Units
VDD Power Supply Voltage 3.135 3.3 3.465 V
VDDO Power Supply Voltage for outputs 1.71 3.465 V
IDD Power supply current, no load 5 mA
TAAmbient Operating Temperature 0+70 °C
-40 +85
tUP Power Supply Ramp Time 4 ms
Symbol Parameter Condition Min. Typ. Max. Units
VIH Input High Voltage CLKIN, OE# VDD/2+1 V
VIL Input Low Voltage CLKIN, OE# VDD/2-1 V
VOH Output High Voltage IOH = -8mA VDDO – 0.4 V
VOL Output Low Voltage IOL = 8mA 0.4 V
ZONominal Output Impedance 20 W
RPD Internal Pull-down Resistor OE# 230 kW
CLKIN 320
CIN Input Capacitance OE# 5pF
CLKIN 7
DC Electrical Characteristics