R Solid-State Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimize Inventory Standard multiple operating modes and multiple time ranges 4PDT or DPDT control output LED power-ON and time-UP indicators Sockets, hold-down clips and mounting accessories may be ordered separately Ordering Information Supply voltage Time-limit contact Short-time range model (0.1 s to 10 min) Long-time range model (0.1 min to 10 h) 24,, 100 to 120,, 200 to 230 VAC;; 12 24, 12, 2 48, 8 100 to 110, 110 125 12 VDC DPDT H3YN-2 H3YN-21 4PDT H3YN-4 H3YN-41 24 VDC 4PDT (Twin contact) H3YN-4-Z H3YN-41-Z Note: Specify both the model number and supply voltage when ordering. Example: H3YN-2 24 VAC Supply voltage MODEL NUMBER LEGEND: 1. Output H3YN 2: DPDT 1 2 3 4: 4PDT 2. Time Range None: Short-time range (0.1 s to 10 min) 1: Long-time range (0.1 min to 10 hrs) 3. Contact Type None: Single contact Z: Twin contact ACCESSORIES (ORDER SEPARATELY) Connecting Socket Applicable Timer Track-mounting/frontg/ connecting i socket k Back-connecting socket Solder terminal Wire-wrap terminal PCB terminal H3YN-2/-21 PYF08A-E, PYF08A-N PY08 PY08QN(2) PY08-02 H3YN-4/-41 H3YN-4-Z/-41-Z PYF14A-E, PYF14A-N PY14 PY14QN(2) PY14-02 Hold-Down Clips Applicable socket Part number PYF08A-E, PYF08A-N, PYF14A-E, PYF14A-N Y92H-3 PY08, PY08QN(2), PY08-02, PY14, PY14QN(2), PY14-02 Y92H-4 Panel Adapter Applicable timer Part number H3YN-2/21. H3YN-4/41, H3YN-4-Z/41-Z Y92F-78 1 H3YN H3YN Specifications RATINGS Item H3YN-2/-4/-4-Z H3YN-21/-41/-41-Z Time ranges 0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max. selectable) 0.1 min to 10 h (1 min, 10 min, 1 h, or 10 h max. selectable) Supply voltage 24, 100 to 120, 200 to 230 VAC; 12, 24, 48, 100 to 110, 125 VDC (see note 1) Operating mode ON-delay, interval,repeat cycle with ON-start or OFF-start (selectable with DIP switch) Operating voltage 85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage) (see note 2) Power consumption 24 VAC: 100 to 120 VAC: 200 to 230 VAC: 12 VDC: 24 VDC: 48 VDC: 100 to 110 VDC: 125 VDC: Control outputs Note: DPDT: 4PDT: Relay ON: 1.1 VA (at 24 VAC, 60 Hz) Relay OFF: 0.2 VA (at 24 VAC, 60 Hz) Relay ON: 14 VA (at 120 VAC, 60 Hz) Relay OFF: 0.6 VA (at 120 VAC, 60 Hz) Relay ON: 1.5 VA (at 230 VAC, 60 Hz) Relay OFF: 0.9 VA (at 230 VAC, 60, Hz) Relay ON: 0.9 W (at 12 VDC) Relay OFF: 0.07 W (at 12 VDC) Relay ON: 0.9 W (at 24 VDC) Relay OFF: 0.7 W (at 24 VDC) Relay ON: 1.0 W (at 48 VDC) Relay OFF: 0.2 W ( at 48 VDC) Relay ON: 1.3 W (at 110 VDC) Relay OFF: 0.3 W (at 110 VDC) Relay ON: 1.3 W (at 125 VDC) Relay OFF: 0.3 W (at 125 VDC) 5 A at 250 VAC, resistive load (cos = 1) 3 A at 250 VAC, resistive load (cos = 1) 1. Single-phase, full-wave-rectified power supplies can be used. 2. When using the H3YN in any place where the ambient temperature is more than 50C, supply 90% to 110% of the rated supply voltages (supply 95% to 110% with 12 VDC type). CHARACTERISTICS Item H3YN-2/-21 Repeat accuracy 1% FS max. (1 s range: 1%10 ms max.) Setting error 10%50 ms FS max. Resetting time Min. power-opening time: 0.1 s max. (including halfway reset) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts) 2,000 VAC, 50/60 Hz for 1 min (between operating circuit and control output) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) 2,000 VAC, 50/60 Hz for 1 min (between contacts of different poles) Vibration Shock Ambient temperature p H3YN-4/-41 2,000 VAC, 50/60 Hz for 1 min (between contacts of different poles) Mechanical durability 10 to 55 Hz, 0.75-mm single amplitude Malfunction durability 10 to 55 Hz, 0.5-mm single amplitude Mechanical durability 1,000 m/s2 (approx. 100G) Malfunction durability 100 m/s2 (approx. 10G) Operating --10C to 50C (14F to 122F) with no icing Storage --25C to 65C (--13F to 149F) with no icing Ambient humidity Operating 35% to 85% RH Service life Mechanical 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical DPDT: 500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) 4PDT: 200,000 operations min. (H3YN-4-Z/-41-Z: 100,000 operations min.) (3 A at 250 VAC, resistive load at 1,800 operations/h) Weight Approx. 50 g Approvals UL/CSA/CE (EMC) (LV) 2 H3YN H3YN Engineering Data ELECTRICAL SERVICE LIFE Electrical Life Expectancy (Reference Value) 250 VAC, cos = 1 24 VDC, cos = 1 5,000 1,000 500 200 Switching operations (x 10 3 ) Switching operations (x 10 3 ) H3YN-2/-21 5,000 250 VAC, cos = 0.4 24 VDC, L/R = 7 ms 1,000 500 200 Load current (A) Load current (A) Reference: A maximum current of 0.6 A can be switched at 125 VDC (cos = 1). Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 1 mA at 5 VDC (P reference value). 250 VAC, cos = 1 24 VDC, cos = 1 5,000 1,000 500 200 Switching operations (x 10 3 ) Switching operations (x 10 3 ) H3YN-4/-41 5,000 250 VAC, cos = 0.4 24 VDC, L/R = 7 ms 1,000 500 200 Load current (A) Load current (A) Reference: A maximum current of 0.5 A can be switched at 125 VDC (cos = 1). Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 1 mA at 1 VDC (P reference value). Switching operations (x 10 3 ) H3YN-4-Z/-41-Z 5,000 1,000 500 220 VAC, resistive load 100 24 VDC, resistive 60 load Load current (A) Reference: A maximum current of 0.5 A can be switched at 125 VDC (cos = 1). Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 0.1 mA at 1 VDC (P reference value). 3 H3YN H3YN Nomenclature Output Indicator (Orange) (Lit: Output ON) Run/Power Indicator (Green) (Lit: Power ON) Main Dial Set the desired time according to time range selectable by DIP switch. Timing Charts Operating mode Timing chart H3YN-2/-21 H3YN-4/-41 Power (13-14) Power (13-14) Time limit contact NC (9-1, 12-4) Run/Power indicator (PW) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Output indicator (UP) Output indicator (UP) Power (13-14) Power (13-14) Time limit contact NC (9-1, 12-4) Run/Power indicator (PW) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Output indicator (UP) Output indicator (UP) ON-delay Power Output Time limit contact NO (9-5, 12-8) Interval Power Output Time limit contact NO (9-5, 12-8) Repeat cycle OFF-start Power (13-14) Power Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Time limit contact NC (9-1, 12-4) Output Time limit contact NO (9-5, 12-8) Run/Power indicator (PW) Output indicator (UP) Output indicator (UP) Repeat cycle ON-start Power (13-14) Power (13-14) Power Time limit contact NC (9-1, 12-4) Output Time limit contact NO (9-5, 12-8) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Note: Run/Power indicator (PW) Run/Power indicator (PW) Output indicator (UP) Output indicator (UP) t: Set time Rt: Reset time 4 H3YN H3YN PULSE OPERATION A pulse output for a certain period can be obtained with a random external input signal. Use the H3YN in interval mode as shown in the following timing charts. H3YN-2/-21 Power (9-14) External short circuit (5-13) 50 ms min. External input (9-13) Time limit contact NO (12-8) Timer circuit Time limit contact NC (12-4) Run/Power indicator (PW) Output indicator (UP) External input Note: t: Set time Rt: Reset time H3YN-4/-41 H3YN-4-Z/-41-Z Power (9-14) External short circuit (5-13) 50 ms min. External input (9-13) Time limit contact NO (10-6, 11-7, 12-8) Timer circuit Time limit contact NC (10-2, 11-3, 12-4) Run/Power indicator (PW) Output indicator (UP) External input Note: t: Set time Rt: Reset time ! Caution Be careful when connecting wires. Mode Terminals Pulse operation Power supply between 9 and 14 Short-circuit between 5 and 13 Input signal between between 9 and 13 5 H3YN H3YN Operation DIP SWITCH SETTINGS The 1-s range and ON-delay mode for H3YN-2/-4/-4-Z, the 1-min range and ON-delay mode for H3YN-21/-41/-41-Z are factory-set before shipping. Time Ranges Model Time range Time setting range H3YN-2, H3YN-4 H3YN-4-Z 1s 0.1 to 1 s Yes 10 s 1 to 10 s No 1 min 0.1 to 1 min No 10 min 1 to 10 min No 1 min 0.1 to 1 min Yes 10 min 1 to 10 min No 1h 0.1 to 1 h No 10 h 1 to 10 h No H3YN-21, H3YN-41 H3YN-41-Z Note: Setting Factory-set The top two DIP switch pins are used to select the time ranges. Operating Modes Operating mode Setting Factory-set ON-delay Yes Interval No Repeat cycle OFF-start No Repeat cycle ON-start No Note: The bottom two DIP switch pins are used to select the operating mode. Connections Part number Power supply terminal numbers Output terminal numbers AC (common), DC- AC (hot), DC+ Type COM NC NO H3YN-21-21 13 14 Timed contacts (DPDT) 9 1 5 H3YN-4/-41 H3YN 4-Z/41-Z 13 14 Timed contacts (4PDT) 9 10 11 12 1 2 3 4 5 6 7 8 6 H3YN H3YN Dimensions Unit: mm (inch) TIMERS H3YN-4/-41 H3YN-4-Z/-41-Z H3YN-2/-21 Fourteen, 3 x 1.2 elliptic holes Eight, 3 x 1.2 elliptic holes 28 max. (1.10) 28 max. (1.10) 52.6 (2.07) 63 (2.48) 6.4 (0.25) 52.6 (2.07) 63.0 (2.48) 21.5 max (0.85) (0.25) 21.5 max (0.85) Overall Mounting Depth PYF08E/PYF08A-N (PYF14A/PYF14-N see note) H3YN series 90.5 (3.56) 86.6 (3.41) PY08 (PY14 see note) 59.3 (7.33) H3YN series 20 (0.79) PYF08A-E (PYF14A-E) PY08 (PY14) PY08QN (PY14QN see note) 59.3 (7.33) 41.5 (1.63) 7 H3YN series PY08QN (PY14QN) Note: Models in parentheses are sockets connecting to the H3YN-4/-4-Z. H3YN H3YN SOCKETS Track-Mounting/Front-Connecting Sockets PYF08A-E Two, 4.2 x 5 mounting holes 6 Terminal Arrangement (Top View) 3.4 Eight, M3 x 8 sems Mounting Holes Mounting Height Two, 4.5 dia. M4 or M3 H3YN Series 72 max. (2.83) 35.4 (0.39) 23 max. (0.91) 590.3 4 (0.15) 6 (0.24) 16.5 (0.65) 90.5 (3.56) 86.6 (3.41) PYFjA 150.2 (.59) 30 max. (1.18) PYF-14A-E Two, 4.2 x 5 mounting holes 6 Terminal Arrangement (Top View) 3.4 Fourteen, M3 x 8 sems 35.4 (1.39) 72 max. (2.83) Mounting Holes Two, 4.5 dia. M4 or M3 590.3 (2.32) 4 (0.16) 6 (0.24) 29 max. (1.16) 220.2 (0.87) 16.5 30 max. (1.18) PYF-08A-N Terminal Arrangement 22 max. (0.87) 4 1 42 12 8 5 44 14 42 4 44 8 Mounting Holes (for Surface Mounting) 12 1 14 5 3.2 dia. 66.5 max (2.62) 19.8 PYF-08A-N 41 11 12 9 A2 A2 A1 14 14 13 12 41 14 3.6 dia. 9 11 14 13 A2 A2 A1 30 max. (1.18) PYF-14A-N 4 3 2 1 42 32 22 12 8 7 6 5 44 34 24 14 Terminal Arrangement 42 32 22 12 4 3 2 1 44 34 24 14 8 7 6 5 Mounting Holes (for Surface Mounting) Two, 3.5 dia. 66.5 max (2.62) PYF-14A-N 31 21 12 11 10 A2 A2 A1 14 14 13 41 29.5 max. (1.16) 11 9 30 max. (1.18) 12 11 10 9 41 31 21 11 14 14 A2 A2 8 13 A1 20.8 H3YN H3YN Back-Connecting Sockets PY08, PY14 Terminal Arrangement (Bottom View) Eight, 3 x 1.2 dia. holes only for PY08 (Fourteen, 3 x 1.2 dia. holes) 24 max. (0.94) 0.3 7.7 (0.30) 27 (0.11) Mounting Height 21.4 +0.2 0 25.5 29.5 max max. (1.16) 2.6 (0.10) 25.8 +0.2 0 PY08 20 max. (0.79) PY14 59.3 (2.33) H3YN Series 20 (0.79) PYj, PYj-02, PYjQN(2) PY08QN, PY14QN PY08QN(2), PY14QN(2) 2.7 (0.10) Panel Cutout Terminal Arrangement (Bottom View) 24 max. (0.94) 22 max. 25 max. * (0.98) (See note) 59.3 (2.33) H3YN series 29.5 max. (1.16) 1x1 ** 41.5 max. (1.63) see note Note: With PYjQN(2)(-3), dimension * should read 20 max. (0.79) and dimension ** 36.5 max. (1.44) PY08-02, PY14-02 4.3 2.7 (0.17) (0.10) 16.5 max. (0.65) PY14QN PY14QN(2) 41.5 (1.63) PYj QN, PYjQN(2) Terminal Arrangement (Bottom View) 22 max. (0.87) 0.3 PY08QN PY08QN(2) 25.5 29.5 max max. (1.16) 2 PY08j-02 PY14j-02 Hold-Down Clips The hold-down clip makes it possible to mount the H3YN securely and prevent the H3YN from falling out due to vibration or shock. 9 H3YN H3YN Y92H-3 Y92H-4 Y92H-3 for PYFjA Socket Y92H-4 for PYj Socket 5 max. 9R 30.5 24.5 2.5 53 (2.09) 20 1.2 4.5 4.5 (84) 33.7 PANEL MOUNT ADAPTER Y92F-78 +0.2 25.1 (0.99) 27.1 (1.07) 25.2 --0 (0.99) +0.2 --0 48.5 (1.91) 33.5 (1.32) MOUNTING TRACK AND ACCESSORIES PFP-100N, PFP-50N 4.5 (0.18) 16 (0.63) 4.5 (0.18) 10 25 25 L 10 25 350.3 270.15 350.3 25 +0.2 --0 PFP-100N2 7.30.15 (0.29) 15 31.6 (1.24) 31.5 (1.24) 15 * 25 25 10 1 (0.04) 25 L 27 24 1 (0.04) 25 15 10 L: Length 1m 50 cm 1m PFP-100N PFP-50N PFP-100N2 End Plate PFP-M Spacer PFP-S 10 (0.39) 6.2 (0.24) 1 50 (1.97) 11.5 (0.45) 1.8 10 M4 x 8 (0.39) pan head screw 1.8 (0.07) 35.3 35.5 (1.39) 16 (0.63) 5 (0.20) 12 34.8 (1.37) 44.3 (1.74) 1.3 (0.05) 4.8 (0.19) 16.5 (0.65) 10 29.2 (1.15) 1.5 (0.06) H3YN H3YN Precautions CORRECT USE Do not set to the minimum setting in the repeat-cycle modes, or the contact may become damaged. When using the H3YN in any place where the ambient temperature is more than 50C, supply 90% to 110% of the rated voltages (at 12 VDC: 95% to 110%). Be careful not to apply any voltage to the terminal screws on the back of the timer. Mount the product so that the screws will not come in contact with the panel or metal parts. Do not leave the H3YN in time-up condition for a long period of time (for example, more than one month in any place where the ambient temperature is high), otherwise the internal parts may become damaged. Therefore, the use of the H3YN with a relay as shown in the following circuit diagram is recommended. Do not use the H3YN in places where there is excessive dust, corrosive gas, or direct sunlight. Do not mount more than one H3YN closely together, otherwise the internal parts may become damaged. Make sure that there is a space of 5 mm or more between any adjacent H3YN Models. The internal parts may become damaged if a supply voltage other than the rated ones is imposed on the H3YN. PRECAUTIONS FOR VDE CONFORMANCE H3YN MY Relay The H3YN as a built-in timer conforms to VDE 0435/P2021 provided that the following conditions are satisfied. The H3YN must be disconnected from the socket when setting the DIP switch, otherwise the user may touch a terminal imposed with a high voltage and get an electric shock. Handling Do not connect the H3YN as shown in the following circuit diagram on the right hand side, otherwise the H3YN's internal contacts different from each other in polarity may become short-circuited. Before dismounting the H3YN from the socket, make sure that no voltage is imposed on any terminal of the H3YN. Correct Do not touch the DIP switch while power is supplied to the H3YN. Wiring The power supply for the H3YN must be protected with equipment such as a breaker approved by VDE. Incorrect Only a load with basic isolation can be connected to the output contact. The H3YN is a model with basic isolation. Therefore, the H3YN and the load will ensure reinforced isolation, thus meeting VDE standards. Insulation requirement: Overvoltage category II, pollution degree 2 (with a clearance of 1.5 mm and a creepage distance of 2.5 mm at 240 VAC) Use the following safety circuit when building a self-holding circuit with the H3YN and an auxiliary relay, such as an MY Relay, in combination. There must be no difference in polarity between any output terminals next to each other of the H3YN-4 or H3YN-41, H3YN-4Z, H3YN-41-Z. : H3YN MY Relay In the case of the above circuit, the H3YN will be in pulse operation. NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMRON ELECTRONICS LLC OMRON ON--LINE OMRON CANADA, INC. 1-800-55-OMRON Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci 416-286-6465 One East Commerce Drive Schaumburg, IL 60173 Cat. No. GC TMCN1 3/02 Specifications subject to change without notice. 11 885 Milner Avenue Scarborough, Ontario M1B 5V8 Printed in U.S.A. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: Y92H-3