12 1-800-735-6200 Rev 3 1 of 2 VI-J00 MiniMod DC-DC Converters 25 to 100 Watts Converter Selection Chart VI-J Features Output Voltage Input Voltage Up to 50W/Cubic Inch UL, CSA, TUV, VDE, BABT CE Marked Up to 90% Efficiency Size: 2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7) Remote Sense and Current Limit Logic Disable Wide Range Output Adjust ZCS Power Architecture Low Noise FM Control Nominal 0 = 1 = W= 2 = 3 = N = 4 = T = 5 = 6 = 7 = The VI-J00 MiniMod family establishes a new standard in component-level DC-DC converters. This "junior" size complement to the higher power VI-200 family offers up to 100W of isolated and regulated power in a board mounted package. At one-half the size and twice the power density of previous 100W modules, and with a maximum operating temperature rating of 100C, the MiniMod opens new horizons for board-mounted (distributed) power architectures. Utilizing Vicor's "zero-currentswitching" forward converter technology, proven by an installed base of over 8 million units, the MiniMod family combines state of the art power density with the efficiency, low noise and reliability required by next generation power systems. Range 12V 10 - 20V(5) n/a 24V 21 - 32V(2) 18V 24V 18 - 36V(2) n/a 36V 21 - 56V(6) 18V 48V 42 - 60V(3) 36V 48V 36 - 76V(2) n/a 72V 55 - 100V(2) 45V 110V 66 - 160V(2) n/a 150V 100 - 200V(2) 85V 300V 200 - 400V(3) 170V 150/300V 100 - 375V(6) 90V Product Grade/ Operating Temp. Product Highlights E = C = I = M= -10C -25C -40C -55C to to to to +100C +100C +100C +100C Z = 2V Y = 3.3V 0 = 5V X = 5.2V W = 5.5V V = 5.8V T = 6.5V R = 7.5V M = 10V 1 = 12V P = 13.8V 22V 36V n/a 60V 72V n/a 110V n/a 215V 425V n/a Product Grade/ Storage Temp. E C I M = = = = -20C -40C -55C -65C 2 N 3 L J K 4 H F D B = 15V = 18.5V = 24V = 28V = 36V = 40V = 48V = 52V = 72V = 85V = 95V Output Power/Current VOUT 5V Z = 25W Y = 50W X = 75W W = 100W to +105C to +105C to +105C to +105C Max. Output For 5V Outputs > 5V Outputs < 5V Outputs (1) 50W 50W 10A (2) 75W 100W 20A 20A (3) 100W 100W Z Y X W VOUT < 5V = 5A = 10A = 15A = 20A Max. Output For 5V Outputs > 5V Outputs < 5V Outputs (4) 75W 75W 15A (5) 50W 75W 15A 10A (6) 50W 75W *Brownout 75% of rated load; transient voltage for 1 second. Mechanical Drawing .49 (12,4) .30.015 (7,6)(0,38) 2.28 (57,9) 1.30 (33,0) .080 Dia (2) places Solder plate over copper alloy .65 (16,5) Pin # 1 4 9 3 8 VI-J00 2.10 (53,4) 2 Packaging Options SlimModsTM, high power density, flangeless packages and FinModsTM, featuring integral finned heatsinks. Brownout / Transient* 1 .15 (3,8) SlimMod: Option suffix: - S Example: VI - JXX - XX - S FinMod: Option suffix: - F1 and - F2 Examples: VI - JXX - XX -F1, 0.75" height VI - JXX - XX -F2, 1.00" height 7 6 5 1.40 1.00 (35,6) .70 (25,4) .40 (17,8) (10,2) .35 .015 (8,9)(0,38) FULL R Function +In 2 Gate In 3 Gate Out 4 -In 5 +Out 6 +Sense 7 Trim 8 -Sense 9 -Out .040 (1,0) Dia (7) places Solder plate over copper alloy .15 (3,8) 2.40 (61,0) Product ID this surface 1.90 (48,3) .30 (7,6) Min. .22 (5,6) Min. .50 (12,7) 1.75 (44,4) Max. +.030 (0,76) -.000 (0) .01 .12 (3,0) Aluminum Base For the latest Vicor Product Information: www.vicorpower.com http://store.iiic.cc/ 12 1-800-735-6200 Rev 3 2 of 2 Converter Specifications (typical at TBP = 25C, nominal line and 75% load, unless otherwise specified) VI-J00 E-Grade PARAMETER MIN. Input Characteristics Inrush charge Input reflected ripple current - pp Input ripple rejection ( ) Dielectric Withstand Characteristics Input to output Output to baseplate Input to baseplate TYP. MAX. UNITS TEST CONDITIONS 60x10 -6 10% 100x10-6 Coulombs IIN Nominal line Nominal line, full load dB 120 Hz, nominal line dB 2400 Hz, nominal line ( ) ( ) 25+20Log Vin Vout Output Characteristics Setpoint accuracy Load/line regulation Load/line regulation Control Pin Characteristics Gate out impedance Gate in impedance Gate in high threshold Gate in low threshold Gate in low current VI-J00 C-, I-, M-Grade MIN. 60x10 -6 10% No load power dissipation Output temperature drift Long term drift Output ripple - pp: 2V, 3.3V 5V 10-48V Trim range1 Total remote sense compensation Current limit Short circuit current MAX. TYP. 30+20Log Vin Vout 20+20Log Vin Vout 1.35 2 1.35 2 Watts 1.0% 2.0% 0.5% 1.0% 0.5% 0.05% 0.2% 1.0% 0.2% 0.5% VNOM VNOM VNOM 0.02 0.02 0.01 0.02 0.02 %/C %/1K hours 200 5% 3% 100 2% 0.75% 150 3% 1.5% 110% mV VNOM 125% 130% Volts INOM INOM 50% 0.5 105% 105% 110% 135% 140% 50% 0.5 105% 105% 50 10 3 6 50 10 3 6 0.65 0.65 6 3,000 500 1,500 6 3,000 500 1,500 Ohms Ohms Volts Volts mA VRMS VRMS VRMS Thermal Characteristics Efficiency Baseplate to sink 78-88% 0.4 80-90% 0.4 C/Watt Mechanical Specifications Weight 3.0 (85) 3.0 (85) Ounces (Grams) 110V, LL to HL, 10% to Full Load LL to HL, No Load to 10% Over rated temperature 20 MHz bandwidth 20 MHz bandwidth 20 MHz bandwidth 0.25V max. neg. leg Automatic restart Use open collector Baseplate earthed With Vicor P/N 04308 12V and 15V outputs, standard trim range 10%. Consult factory for wider trim range. For product compliance with agency standards please refer to pages 67 - 69. For the latest Vicor Product Information: www.vicorpower.com http://store.iiic.cc/ 73