www.recom-power.com REV.: 5/2019 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
ROE
Series
ENVIRONMENTAL
Parameter Condition
Operating Temperature Range without derating @free air convection (see graph) -40°C to +85°C
Operating Humidity non-condensing 95% RH max.
Vibration MIL-STD-202G
MTBF (5)
according to MIL-HDBK-217F; G.B. +25°C
+85°C
20140 x 103 hours
8674 x 103 hours
-40 -20 0 20 40 7060-30 -10 10 30 50 80
85
90 110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Derating Graph
Notes:
Note5: MTBF is referring ROE-3.305S
SAFETY AND CERTIFICATIONS
Information Technology Equipment, General Requirements for Safety E358085-A4-UL UL60950-1, 2nd Edition, 2007
CAN/CSA C22.2 No.60950-1-07, 2nd Edition, 2007
Information Technology Equipment, General Requirements for Safety SPCLVD1602031 IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
EAC RU-AT.49.09571 TP TC 004/2011
RoHS 2+ RoHS-2011/65/EU + AM-2015/863
Electromagnetic compatibility of multimedia equipment -
Emission requirements
with external filter
(see filter suggestion below)
EN55032, Class B
EN55032, Class A
PROTECTIONS
Parameter Condition Value
Isolation Voltage (3) I/P to O/P tested for 1 second
Isolation Capacitance 75pF max.
Isolation Resistance 1GΩ min.
Notes:
Note3: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note4: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: T1A slow blow type