–1– AECTB55E 201701-T
ORDERING INFORMATION
PRODUCT TYPES
Terminal type (solder terminal)
Wire leads type
Long Stroke, Sliding
Contact Construction
Sealed Switches
Turquoise Stroke
Mini Switches
Actuator Right 2 boss type Left 2 boss type
Normally Closed type (NC) Normally Open type (NO) Normally Closed type (NC) Normally Open type (NO)
Pin plunger ASQM16420 ASQM16430 ASQM17420 ASQM17430
Simulated roller lever ASQM16428 ASQM16438 ASQM17428 ASQM17438
Actuator Normally Closed type (NC) Normally Open type (NO)
Pin plunger ASQM11620 ASQM11630
Simulated roller lever ASQM11628 ASQM11638
FEATURES
Miniaturization achieved with
changing from 1 Form C to 1 Form A
or 1 Form B contacts.
(For the terminal type, volume has
been cut 45% compared to our
previous product.)
Lever installation possible while it is
small size.
Operation possible by various
moving parts such as metal cams.
Contact force does not depend on
the operation stroke.
High contact reliability to support
low level switching loads.
Highly effective sealing for
resistance against adverse
environments. (IP67)
Silent operation with sliding
contacts.
TYPICAL APPLICATIONS
Automobiles (detection of door
opening and closing, shift lever
position, etc.)
Household appliances (vacuum
cleaners, air conditioners, washing
machines, electric power tool, etc.)
5.3
8.3
7.85
Terminal type
Wire leads type
5.3
8.3
13.55
(Unit: mm)
RoHS compliant
ASQM1
Mounting
1: Without boss type (wire leads type only)
6: Right 2 boss type (terminal type only)
7: Left 2 boss type (terminal type only)
Note: Not every combination is available. Please refer to the following table, “PRODUCT TYPES”.
Contact form
2: Normally Closed type (NC)
3: Normally Open type (NO)
Actuator
0: Pin plunger
8: Simulated roller lever
Terminal
4: Terminal type (Solder terminal)
6: Wire leads type
Carton: 1,000 pcs.
Carton: 240 pcs.
Turquoise Stroke Mini Switches (ASQM1)
–2– AECTB55E 201701-T
SPECIFICATIONS
Contact rating
1 mA 5 V DC to 50 mA 16 V DC
Operation environment and conditions
Note: When switching at low and high speeds or under vibration, or in high-temperature, high-humidity environments, life and performance may be reduced significantly
depending on the load capacity. Please consult us.
Electrical characteristics
Characteristics
Notes: As long as there are no particular designations, the following conditions apply to the test environment.
• Ambient temperature: 5 to 35°C
• Relative humidity: 25 to 85% RH
• Air pressure: 86 to 106 kPa
Protection grade
Item Specifications
Ambient and storage temperature –40°C to +85°C (no freezing and condensing)
Allowable operating speed 30 to 500 mm/sec.
Max. operating cycle rate 120 cpm
Item Specifications
Dielectric strength (Initial) Between non-continuous terminals: 500 Vrms, Between each terminal and other exposed metal parts: 1,500 Vrms,
Between each terminal and ground: 1,500 Vrms (at detection current of 1 mA)
Insulation resistance (Initial) Min. 100 MΩ (at 500 V DC insulation resistance meter) (Locations measured same as dielectric strength.)
Contact resistance (Initial) Max. 500 mΩ (by voltage drop 50 mA 6 to 8 V DC)
Item Specifications
Electrical
switching life
5 V DC 1 mA (Resistive load) Min. 3 × 105Switching frequency: 20 times/min.
Conduction ratio: 1:1
Plunger operation speed: 100 mm/s
Plunger switching position: Free Position (FP) to Total Travel Position (TTP)
12 V DC 50 mA (Resistive load) Min. 2 × 105
16 V DC 50 mA (Resistive load) Min. 1.5 × 105
Vibration resistance
(malfunction vibration resistance)
Single amplitude: 0.75 mm
Amplitude of vibration: 10 to 55 Hz (4 minutes cycle)
Direction and time: 30 minutes each in X, Y and Z directions
Amplitude of vibration: 5 to 200 Hz (10 minutes cycle)
Acceleration: 43.1 m/s2
Direction and time: 30 minutes each in X, Y and Z directions
Shock resistance
(malfunction shock resistance)
Shock value: 980 m/s2
Direction and time: 5 times each in X, Y and Z directions
Terminal strength Min. 6 N (each direction) *Terminal deformation possible.
Heat resistance 85°C 500 hours
Cold resistance –40°C 500 hours
Humidity resistance 40°C 95% RH 500 hours
Unit weight Approx. 0.5 g (Terminal type), Approx. 3.9 g (Wire leads type)
Protection grade IP67 (except exposed terminal part of terminal type)
1) JIS C0920 (water-resistance experiments for electrical
machines and protection rating against incursion of solid
substances): Immersion protected (Note 1)
2) IEC 60529 (rating for outer shell protection): IP67 (Immersion
protected) (Note 1)
except metal terminal part (See below drawing)
3) JIS D0203 (method for testing moisture resistance and water
resistance in automotive components): Equivalent of D2 (Note 2)
Note 1) A concrete testing method is to check for any adverse effect on the structure
after leaving it submerged for 30 minutes under 1 m of water (with
temperature difference between water and switch no larger than 5°C).
Note 2) A concrete testing method is to check for any adverse effect on the structure
after leaving it submerged for 10 minutes under 10 cm water (with
temperature difference between water and switch no larger than 30°C).
Metal terminal part
Turquoise Stroke Mini Switches (ASQM1)
–3– AECTB55E 201701-T
Operating characteristics
Note: The above indicates the characteristics when operating the actuator from the vertical direction.
DATA
Applicable current range (Reference)
DIMENSIONS (Unit: mm)
Terminal type (Solder terminal), Right 2 boss type, Pin plunger
Characteristics Pin plunger Simulated roller lever
Operating Force (OF) max. 1.2N 1.5N
Total Travel Force (TF) max. (Reference value) (3.0N) (2.8N)
Free Position (FP) max. Terminal type 7.7mm 13.4mm
Wire leads type 14.45mm 20.15mm
Operating Position (OP)
Terminal type Initial: 7.1±0.25mm
After test: 7.1±0.3mm
Initial: 10.75±0.6mm
After test: 10.75±0.7mm
Wire leads type Initial: 13.75±0.35mm
After test: 13.75±0.4mm
Initial: 17.4±0.7mm
After test: 17.4±0.8mm
Release Position (RP)
Terminal type Initial: 7.15±0.3mm
After test: 7.15±0.35mm
Initial: 11.05±0.7mm
After test: 11.05±0.8mm
Wire leads type Initial: 13.8±0.4mm
After test: 13.8±0.45mm
Initial: 17.7±0.8mm
After test: 17.7±0.9mm
Over Travel (OT) min.
Terminal type Initial: 1.75mm
After test: 1.70mm
Initial: 2.25mm
After test: 2.15mm
Wire leads type Initial: 1.65mm
After test: 1.60mm
Initial: 2.15mm
After test: 2.05mm
Total Travel Position (TTP)
(Reference value)
Terminal type (5.1mm) (7.9mm)
Wire leads type (11.75mm) (14.55mm)
Applicable range
50mA
1mA
0
16V5VDC
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
2.6±0.05
5.3±0.15
4.08±0.15
5.0±0.1
8.3
4.0
2.0
1.2
2.0
0.4
1.9 dia.
2.2 dia.
2.6±0.05
3.854.03.2
0.6 1.8 3.6 3.35
FP 7.7 max.
RP 7.15±0.3
OP 7.1±0.25
TTP (5.1)
2.2 dia.
Operating Force (OF) max. 1.2N
Total Travel Force (TF) max.
(Reference value) (3.0N)
Free Position (FP) max. 7.7mm
Operating Position (OP) Initial: 7.1±0.25mm
After test: 7.1±0.3mm
Release Position (RP) Initial: 7.15±0.3mm
After test: 7.15±0.35mm
Over Travel (OT) min. Initial: 1.75mm
After test: 1.70mm
Total Travel Position (TTP)
(Reference value) (5.1mm)
CAD Data
General tolerance: ±0.25
Turquoise Stroke Mini Switches (ASQM1)
–4– AECTB55E 201701-T
Terminal type (Solder terminal), Left 2 boss type, Pin plunger
Terminal type (Solder terminal), Right 2 boss type, Simulated roller lever
Terminal type (Solder terminal), Left 2 boss type, Simulated roller lever
External dimensions
2.6±0.05
5.0±0.1
4.08±0.15
8.3
4.0
2.0
1.2
5.3±0.152.0
0.4
1.9 dia.
2.6±0.05
2.2 dia.
3.854.03.2
FP 7.7 max.
RP 7.15±0.3
OP 7.1±0.25
TTP (5.1)
0.6 1.8 3.6 3.35
2.2 dia.
Operating Force (OF) max. 1.2N
Total Travel Force (TF) max.
(Reference value) (3.0N)
Free Position (FP) max. 7.7mm
Operating Position (OP) Initial: 7.1±0.25mm
After test: 7.1±0.3mm
Release Position (RP) Initial: 7.15±0.3mm
After test: 7.15±0.35mm
Over Travel (OT) min. Initial: 1.75mm
After test: 1.70mm
Total Travel Position (TTP)
(Reference value) (5.1mm)
CAD Data
General tolerance: ±0.25
External dimensions
2.6±0.05
5.3±0.15
4.08±0.15
5.0±0.1
8.3
(8.6)
2.0
1.2
2.0
0.4
3.3
2.2 dia.
2.6±0.05
3.854.03.2
0.6 1.8 3.6 3.35
FP 13.4 max.
RP 11.05±0.7
OP 10.75±0.6
TTP (7.9)
2.2 dia.
R2.0
Operating Force (OF) max. 1.5N
Total Travel Force (TF) max.
(Reference value) (2.8N)
Free Position (FP) max. 13.4mm
Operating Position (OP) Initial: 10.75±0.6mm
After test: 10.75±0.7mm
Release Position (RP) Initial: 11.05±0.7mm
After test: 11.05±0.8mm
Over Travel (OT) min. Initial: 2.25mm
After test: 2.15mm
Total Travel Position (TTP)
(Reference value) (7.9mm)
CAD Data
General tolerance: ±0.25
External dimensions
2.6±0.05
5.3±0.15
4.08±0.15
5.0±0.1
8.3
(8.6)
2.0
1.2
2.0
0.4
3.3
2.2 dia.
2.6±0.05
3.854.03.2
0.6 1.8 3.6 3.35
FP 13.4 max.
RP 11.05±0.7
OP 10.75±0.6
TTP (7.9)
2.2 dia.
R2.0
Operating Force (OF) max. 1.5N
Total Travel Force (TF) max.
(Reference value) (2.8N)
Free Position (FP) max. 13.4mm
Operating Position (OP) Initial: 10.75±0.6mm
After test: 10.75±0.7mm
Release Position (RP) Initial: 11.05±0.7mm
After test: 11.05±0.8mm
Over Travel (OT) min. Initial: 2.25mm
After test: 2.15mm
Total Travel Position (TTP)
(Reference value) (7.9mm)
CAD Data
General tolerance: ±0.25
Turquoise Stroke Mini Switches (ASQM1)
–5– AECTB55E 201701-T
Wire leads type, Pin plunger
Wire leads type, Simulated roller lever
External dimensions
5.5±0.15
5.3±0.15
8.3±0.1
(Boss-Hole)
12.9±0.4
2.1
0.9
COM NO/NC
8.3
8.5
3.2
C0.45
1.9 dia.
R3.05
3.0 dia.
+0
0.1
3.0
6.1
+0.1
0
5±2
300±10
(10.5)
FP 14.45 max.
Sealing compound
climbing up the
wire leads: 5 max.
Burge of the
sealing compound:
2 max.
RP 13.8±0.4
OP 13.75±0.35
TTP (11.75)
Operating Force (OF) max. 1.2N
Total Travel Force (TF) max.
(Reference value) (3.0N)
Free Position (FP) max. 14.45mm
Operating Position (OP) Initial: 13.75±0.35mm
After test: 13.75±0.4mm
Release Position (RP) Initial: 13.8±0.4mm
After test: 13.8±0.45mm
Over Travel (OT) min. Initial: 1.65mm
After test: 1.60mm
Total Travel Position (TTP)
(Reference value) (11.75mm)
CAD Data
General tolerance: ±0.25
External dimensions
300±10
5.5±0.15
5.3±0.15
8.3±0.1
(Boss-Hole)
12.9±0.4
2.1
0.9
COM
NO/NC
8.3
(3.7)
R2.0
8.5
3.3
3.2
C0.45
3.0 dia.
+0
0.1
3.0
6.1
+0.1
0
5±2
(10.5)
FP 20.15 max.
Sealing compound
climbing up the
wire leads: 5 max.
Burge of the
sealing compound:
2 max.
RP 17.7±0.8
OP 17.4±0.7
TTP (14.55)
R3.05
Operating Force (OF) max. 1.5N
Total Travel Force (TF) max.
(Reference value) (2.8N)
Free Position (FP) max. 20.15mm
Operating Position (OP) Initial: 17.4±0.7mm
After test: 17.4±0.8mm
Release Position (RP) Initial: 17.7±0.8mm
After test: 17.7±0.9mm
Over Travel (OT) min. Initial: 2.15mm
After test: 2.05mm
Total Travel Position (TTP)
(Reference value) (14.55mm)
CAD Data
General tolerance: ±0.25
Turquoise Stroke Mini Switches (ASQM1)
–6– AECTB55E 201701-T
CAUTIONS FOR USE
Soldering conditions
The application of excessive heat upon
the switch when soldering can cause
degradation of switch operation.
Therefore, be sure to keep within the
conditions given below.
• Manual soldering: Use soldering irons
(max. 350°C, within 3 seconds) capable
of temperature adjustment. This is to
prevent deterioration due to soldering
heat. Care should be taken not to apply
force to the terminals during soldering.
(More than one second interval is
required to apply heat at each terminal.)
Please consult us if you intend to use a
soldering iron that exceeds 60 W.
Mounting
To secure the wire leads type switch,
please use M3 small screws on a flat
surface and tighten using a maximum
torque of 0.29 N·m.
Be sure to verify the quality under actual
conditions of use because the switch
plastic might be deformed according to
that the kind of the screw (size of screw
head etc.), the diameter of the washer
and the presence of washer. And use of
adhesive lock is recommended to prevent
loosening of the screws. When using an
adhesive, care should be taken not to
invade the adhesive into the switches.
• Be sure to maintain adequate insulating
clearance between each terminal and
ground.
The positioning of the switch should be
such that direct force is not applied to the
plunger or actuator in its free position.
The operating force to the plunger should
only be applied in a perpendicular
direction.
When slanted press operation is applied
to pin plunger type switches by an
operation cam, the endurance life may
greatly vary depending on the use of
grease for sliding, operation angle,
operation speed, operation frequency,
press amount of the pin plunger, cam
material, cam shape, cam surface
condition, etc. Therefore fully verification
by using the actual equipment in advance
should be implemented.
• After mounting please make sure no
pulling load will be applied to the switch
terminals.
Cautions regarding the circuit
• In order to prevent malfunction in set
devices caused by bounce and chattering
during the ON-OFF switch operation,
please verify the validity of the circuit
under actual operating conditions and
temperature range.
When switching inductive loads (relays,
solenoids, buzzers, etc.), it is
recommended that contact protection
element such as diode, varistor, etc., is
introduced to prevent contact failure
caused by electric discharge.
Please verify under actual
conditions.
• Please be sure to conduct quality
verification under actual operating
conditions in order to increase reliability
during actual use.
Selection of switch
• Please make your selection so that
there will be no problems even if the
operating characteristics vary up to ±20%
from the standard values.
Oil-proof and chemical-proof
characteristics
• Do not use alcohol-based solvents.
The rubber cap swells when exposed to
oil and chemicals. The extent of swelling
will vary widely depending on the type
and amount of oil and chemicals.
Check with the actual oil or chemicals
used. In particular, be aware that solvents
such as freon, chlorine, toluene, etc.,
cannot be used.
Operation environment
• Although continuous operation of the
switch is possible within the range of
ambient temperature (humidity), as the
humidity range differs depending on the
ambient temperature, the humidity range
indicated below should be used.
Continuous use near the limit of the
range should be avoided.
This temperature-humidity range does
not guarantee permanent performance.
Others
• Do not handle the switch in a way that
may cause damage to the sealing rubber
cap.
• Please remember that this switch
cannot be used under water. Also,
pleased be warned that switching and
sudden temperature changes with the
presence of water droplets can cause
seepage into the unit.
• Keep away from environments where
silicon based adhesives, oil or grease are
present as faulty contacts may result
from silicon oxide. Do not use in areas
where flammable or explosive gases from
gasoline and thinner, etc., may be
present.
When using the lever type, please be
careful not to apply unreasonable load
from the reverse or lateral directions of
operation.
• Do not exceed the total travel position
(TTP) and press the actuator. This could
cause operation failure.
Also, when switching at high speed or
under shock even within the operation
limit, the working life may decrease.
Therefore, please be sure to verify the
quality under actual conditions of use.
• Please make considerations so that the
switch does not become the stopper for
the moving part.
• Do not use the switch which was
dropped by mistakes when handling. If it
is used, abnormal operation
characteristics and sealing performance
may occur.
• In case of applying coating to movable
parts (actuator, plunger, etc.), the quality
of the product is not guaranteed because
it may cause a product failure.
• In case of cleaning a switch, the quality
of the product is not guaranteed because
it may cause a product failure.
• Do not apply ultrasonic vibrations and
high frequency vibration to a switch
because it may have an impact on the
characteristics of the switch.
• Please do not constantly apply a tensile
load to wire leads when fixing them.
Acceptable range
(Avoid
condensation when
used at temperatures
higher than 0°C)
(Avoid freezing when
used at temperatures
lower than 0°C)
95
50
5
–40 0 +85+40
Temperature, °C
Humidity, %R.H.
–1– AECTB35E 201510-T
CAUTIONS FOR USE (Common for BJ, BS and BV types)
Notes for Turquoise Switches (BJ, BS, BV type)
Fastening of the switch body
1) Fasten the switch body onto a smooth surface using the
correct screw as shown in the chart below and tighten it with the
prescribed torque.
The switch case may deform depending on the type of screw
(screw head diameter, etc.), the size of the washer, and the use
or non-use of a washer. Therefore, please confirm the
appropriate torque of actual conditions. Also, it is recommended
that adhesive be applied to lock the screws to prevent loosening
of the screws. When doing so, please be careful not let any
adhesive get inside the switch.
2) Fixed pin type
To secure the switch unit, thermally crimp or press-fit the
mounting pins. If the pins are to be press-fitted, install a guide on
the opposite surface to the mounting pins to prevent them from
slipping out of position and developing play.
3) Be sure to maintain adequate insulating clearance between
each terminal and ground.
4) The positioning of the switch should be such that direct force
is not applied to the pushbutton or actuator in its free position.
The operating force to the pushbutton should only be applied in
a perpendicular direction.
5) The standard value of overtravel used should be within the
range of 70% to 100% of the rated OT value.
6) When soldering the BV type turquoise switch or the
immersion protected type of the BJ and BS type switches, the
sealing material sometimes forms a lump or bulge at the base of
the terminal or lead. Be sure to allow enough space for this
when attaching the switch.
Soldering operations
1) Manual soldering: Perform soldering in less than 3 seconds
with maximum 350°C iron. Care should be taken not to apply
force to the terminals during soldering. We recommend a
soldering iron with temperature adjustment in order to prevent
poor quality soldering.
Please consult us if you intend to use a soldering iron of 60 W or
higher.
2) Terminal portions should not be moved within 1 minute after
soldering.
Selection of the switch
Allow for up to ±20% variation of the specified characteristics
values to compensate for long term operational wear of the
switch in your design.
Cautions regarding use
1) When switching inductive loads (relays, solenoids, buzzers,
etc.), an arc absorbing circuit is recommended to protect the
contacts.
2) If switching of the contact is synchronized with the phase of
the AC power, reduced electrical life or welded contact may
occur. Therefore, test the switch while it is operating under actual
loads for this condition. If found, you may wish to take corrective
action in your design.
3) In the slow or high speed operating condition, the electrical
life might be greatly reduced depending upon the switching load.
Please consult us before use.
4) Using lever type in do not condition, there is the concern that
the flexible part may be impeded and return movement may not
be possible. In this situation take the following precautions:
• Select a product of higher OF or use a leaf type lever.
• Attach a protective cover to the lever.
5) If the leaf lever type switch is excessively pushed (pushed
further than the operational limit position) or switching is done at
high speed or is accompanied by the impact, the lever will break.
Please be careful. Also, be careful with the short roller lever type
ABV (BV) switch as improper return may result from pressing
too much.
Protection from dust, water and corrosive gas
1) The pin button and the space around the body cap Turquoise
switches are sealed with elastic material, the terminal portion is
integrally molded. This prevents dust entry and protects the
switch against corrosive gases. Wireleaded types are
recommended for applications subject to water or oil splash.
However, avoid soaking these immersion protected types in oil
or water, because those types are not of completely oil tight
construction.
2) Switch operation or rapid temperature change while water
droplets are on the switch may cause the water invasion inside
the switch because of breathing action on condensation.
Especially do not use switch in a bath.
If sources of silicon gas are existing in the vicinity of the switch
(silicon rubber, silicon oil, silicon coating, and silicon filler, etc.),
silicon gas (low molecular siloxane, etc.) will be emitted and it
will get into the product due to the permeability of the plastic.
If the switch is used or stored in such an environment, silicon
compound might generate on the contacts, cause the and faulty
contacting. Therefore, please do not use sources that can emit
silicon gas in the vicinity of the switch.
Do not use in areas where flammable or explosive gases from
gasoline and thinner, etc., may be present.
Screws Tightening torque
ABJ (BJ) switches
M1.2 Not more than 0.098N·m
M2.3 Not more than 0.29N·m
M3.0 Not more than 0.29N·m
ABS (BS) switches M2.3 Not more than 0.29N·m
ABV (BV) switches M3.0 Not more than 0.49N·m
Soldering time
ABJ (BJ) switches Within 3 seconds
ABS (BS) switches Within 3 seconds
ABV (BV) switches Within 5 seconds
Notes for Turquoise Switches (BJ, BS, BV type)
–2– AECTB35E 201510-T
REFERENCE
• Dust protection test
Test conditions: The talcum powder used shall be able to pass
through a square- meshed sieve the nominal wire diameter of 7
μm. The amount of talcum powder to be used is 2 kg per cubic
metre of the test chamber volume. The duration of the test is 8
hours.
No damage observed after the test.
• Waterproof test
Test conditions: Immersion protected IP67 switches ...
Submerge at 1 m below the water surface for 30 minutes.
• Hydrogen sulfide exposure test
Test conditions: Concentration: 3 ppm, Temperature: 40°C
104°F, Humidity: 75% RH
Oil-proof and chemical-proof characteristics
The rubber elastomer swells when exposed to oil and chemicals.
The extent of swelling will vary widely depending on the type and
amount of oil and chemicals.
Check with the actual oil or chemicals used.
In particular, be aware that solvents such as freon, chlorine, and
toluene cannot be used.
Washability [ABJ (BJ) and ABS (BS)]
Do not clean the switch. Doing so can cause problems. Please
contact us if cleaning is necessary.
1Ω
100mΩ
10mΩ
2 4 6 8 10 12 14 16 18 20 22 24
Standard
value 8 hours
Elapsed time (h)
Contact resistance
1000
100
10
2 4 6 8 10 12 14 16 18 20 22 24
Standard value
30 minutes
Elapsed time (h)
Insulation resistance (MΩ)
0 100 200 300 400 500
100Ω
10Ω
1Ω
100mΩ
10mΩ
Elapsed time (h)
Contact resistance
Turquoise switches
Typical products
Dust-protected type
This type of construction prevents dust that is large enough to
have an effect on operation from getting inside the unit. This
construction is stipulated by protective classes against solid
matter in the IEC standards (IEC60529).
The talcum powder used shall be able to pass through a square-
meshed sieve the nominal wire diameter of 7 μm. The amount of
talcum powder to be used is 2 kg per cubic metre of the test
chamber volume. The duration of the test is 8 hours.
No damage observed after the test.
Immersion-protected type
This type of construction prevents any harmful effects even after
the device is left underwater at a depth of 1 m for 30 minutes.
This construction is stipulated by protective classes against
water in the IEC standards (IEC60529).
IEC’s IP Codes
The IEC (International Electrotechnical Commission) has
defined the IP characteristic code that represents the levels of
protection described in IEC standard (IEC60529).
The two numbers that follow the IP code (the characteristics
numbers) indicate the suitability of this protection for all
environmental conditions.
• Level of protection indicated by the 1st Characteristics number
• Level of protection indicated by the 2nd Characteristics number
Note: Details of test conditions are the same as NECA C 0920. Please refer to them.
1st characteristics number
2nd characteristics number
IP
1st
Characteristics number Protection level (IEC60529/Solid matter)
0 No protection
1 Protected against solid matter larger than 50mm
2 Protected against solid matter larger than 12mm
3 Protected against solid matter larger than 2.5mm
4 Protected against solid matter larger than 1.0mm
5
Dust-protected type
Prevents dust that is large enough to have an effect
on operation from getting inside the unit
6Dust-resistant type
Prevents dust from getting inside the unit
JIS C0920
2nd
Characteristics
number
Protection level (IEC60529/Liquid matter)
0 No protection
Droplet-protected
type I 1Protected against water droplets that fall
perpendicular to the unit
Droplet-protected
type II 2Protected against water droplets that fall
from within 15° of perpendicular to the unit
Rain-protected
type 3Protected against water droplets that fall
from within 60° of perpendicular to the unit
Splash-protected
type 4Protected against water that splashes on
the unit from any direction
Spray-protected
type 5Free from adverse effects even if sprayed
directly with water from any direction
Water-resistant
type 6Protected against water sprayed directly
on the unit from any direction
Immersion-
protected type 7
Water does not get inside of the unit when
submerged in water according to the
specified conditions
Underwater type 8 Unit can be used underwater