313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Embedded Power for
Business-Critical Continuity
NFS110 Medical
Series
Single and
quad output
Special Features
•7.0 x 4.25 x 1.8 inch package
•Medical, dental and
laboratory applications
•Overvoltage and short circuit
protection
•110 W with 20 CFM
•UL, VDE and CSA safety
approvals
•EN60601-1 and UL2601
medical approvals
•Available RoHS compliant
•2 year warranty
Total Power: 80 - 110 W
Input Voltage: 90 - 253 Vac
127 - 357 Vdc
# of Outputs: Single, quad
Safety
• VDE0805/EN60601-1/
• IEC60601/IEC1010
• File No. 10401-3336-1049
• Licence No. 2874
• UL60601-1 File No. E182560
• CSA C22.2 No. 125
• File No. LR41062C
ElectricalSpecications
Allspecicationsaretypicalatnominalinput,fullloadat
25 °C unless otherwise stated
Output
Voltage adjustability: +5.1 V o/p on multi’s
5.1 V single output
12 V single output
15 V single output
24 V single output
± 3.0%
± 3.0%
12 - 14 V
15 - 18 V
24 - 30 V
Line regulation: LL to HL, FL
All outputs on all units
± 0.1% max.
Overshoot/undershoot: At turn-on no lead 0%
Temperaturecoefcient: All outputs ±0.02% / °C
Overvoltage protection: Multi o/p 5.1 V only
5.1 V single
12 V single
15 V single
24 V single
6.25 V ± 0.75 V
6.25 V ± 0.75 V
15.75 V ± 1.0 V
22 V ± 1.5 V
33 V ± 2.5 V
Output power limit: Primary power
limited
Pin max. 160 W
Pout min. 110 W
Short circuit protection: Burst mode operation
Input
Input voltage range: 90 - 253 Vac
127 - 357 Vdc
Input frequency range: 47 - 440 Hz
Input surge current: 110 Vac. 50 Hz
230 Vac. 50 Hz
17 A
25 A
Safety ground leakage current: 132 Vac
264 Vac
50 µA
100 µA
Rev. 06.18.10_139
NFS110-M Series
1 of 5
Rev. 06.18.10_139
NFS110-M Series
2 of 5
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
EnvironmentalSpecications
Thermal performance: Operating, see curve 0° C to +70 °C
(See notes 9, 10) Non-operating -40 °C to +85 °C
0 °C to 50 °C amb. convection cooled 80 W
+50 °C to +70 °C,
amb. convection cooled
Derate 2 W/°C
0 °C to +50 °C, 20 CFM forced air 110 W
+50 °C to +70 °C, 20CFM forced air Derate 2.75 W/°C
Peak, 0 °C to +50 °C, max. 60 seconds 110W
Relative humidity: Non-condensing 5% to 95% RH
Altitude: Operating 10,000 feet max.
Non-operating 40,000 feet max.
Vibration (See Note 11): 5-500 Hz 2.4 G rms peak
EMC Characteristics
Conducted emissions: EN55022, FCC part 15 Level A
Radiated emissions: EN55022, FCC part 15 Level A
ESD air: EN61000-4-2, level 3 Perf. criteria 1
ESD contact: EN61000-4-2, level 4 Perf. criteria 1
Surge: EN61000-4-3, level 3 Perf. criteria 1
Fast transients: EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity: EN61000-4-5, level 3 Perf. criteria 2
Conducted immunity: EN61000-4-6, level 3 Perf. criteria 2
GeneralSpecications
Hold-up time: 110 Vac @ 80 W
110 Vac @ 110 W
230 Vac @ 80 W
230 Vac @ 110 W
35 ms
17 ms
140 ms
100 ms
Efciency: Multiple outputs
+5.1 V single
12 V and 15 V singles
24 V single
70% typical
70% typical
72% typical
75% typical
Isolation voltage: Input/output
Input/chassis
4000 Vac
1500 Vac
Approvals and standards:
(see note 12) VDE0750, IEC60601, IEC1010, UL60601,
CSA C22.2 No. 125
Weight: Singles
Multiple outputs
550 g (19.4 oz)
600 g (21.2 oz)
MTBF (@25 ºC) MIL-HDBK-217E 125,000 hours min.
Rev. 06.18.10_139
NFS110-M Series
3 of 5
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Notes
1 Convection cooled, 80 W maximum.
2 Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total
peak power must not exceed 110 W.
3 Forced air, 20 CFM at 1 atmosphere, 110 W maximum.
4 Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth
using a 12 inch twisted pair terminated with a 47 µF capacitor.
5 Totalregulationisdenedatthestaticoutputregulationat25°C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings. Also for NFS110-7902PJ, for 24 V output stated
regulation IA / IB ² 5. This output will maintain ±5.0% regulation if
IA ² 5 A, where IA = +5.1 V output current and IB = +24 V output current.
6 Singleoutputmodelshaveoatingoutputswhichmaybereferencedaseither
positive or negative. Higher voltage supplies, may be adjusted over a wide
output voltage range, as long as the total output power does not exceed 80
Watts (natural convection) or 110 Watts (forced air).
7 Power fail detect not available on single output models.
8 Deratingcurveisapplicationspecicforambienttemperatures>50°C,
for optimum reliability no part of the heatsink should exceed 90 °C and no
semiconductor case temperature should exceed 100 °C.
9 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
10 The user should read the PSU installation instructions in conjunction with the
relevant national safety regulations in order to ensure compliance.
11 Three orthogonal axes, random vibration, 10 minute test for each axis.
12 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
13 The‘J’sufxindicatesthatthesepartsarePb-free(RoHS6/6)compliant.TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please contact your local sales representative for details.
14 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
searchtoolathttp://www.Emerson.com/EmbeddedPowertondasuitable
alternative.
Ordering Information
Output
Voltage
Output Currents
Ripple (4) Total
Regulation (5) Model Numbers (13, 14, F)
Max (1) Peak (2) Fan (3)
+5.1 V 8 A 20 A 10 A 50 mV ± 2.0% NFS110-7901PJ
+12 V 4.5 A 9 A 5 A 120 mV ± 3.0%
–12 V 0.5 A 1.5 A 1 A 120 mV ± 3.0%
–5 V 0.5 A 1.5 A 1 A 50 mV ± 3.0%
+5.1 V (IA)8 A 20 A 10 A 50 mV ± 2.0% NFS110-7902PJ
+24 V (IB) (6) 3.5 A 4.5 A 4.5 A 240 mV +10/–5.0%
+12 V 4.5 A 9 A 5 A 120 mV ± 3.0%
–12 V 0.5 A 1.5 A 1 A 120 mV ± 3.0%
12 V 7 A 9 A 9 A 120 mV ± 2.0% NFS110-7912J (7,8)
15 V 5 A 7.3 A 7.3 A 150 mV ± 2.0% NFS110-7915J (7,8)
24 V 3.5 A 4.5 A 4.5 A 240 mV ± 2.0% NFS110-7924J (7,8)
Transient Response
NFS110-7901PJ +5.1 V (7.5-10 A) 150 mV peak,
1 ms recovery
+12 V (2.5-5 A) 100 mV peak,
0.5 ms recovery
-12 V (0.5-1 A) 100 mV peak,
0.5 ms recovery
-5 V (0.5-1 A) 100 mV peak,
0.5 ms recovery
NFS110-7902PJ +5.1 V (7.5-10 A) 150 mV peak,
1 ms recovery
+12 V (2.5-5 A) 100 mV peak,
0.5 ms recovery
-12 V (0.5-1 A) 100 mV peak,
0.5 ms recovery
24 V (1.5-3 A) 300 mV peak,1
ms recovery
NFS110-7905J +5.1 V (10-20 A) 250 mV peak,
1 ms recovery
NFS110-7912J +12 V (4.5-9 A) 360 mV peak,
1 ms recovery
NFS110-7915J +15 V (3.65-7.3 A) 450 mV peak,
1 ms recovery
NFS110-7924J +24 V (2.25-4.5 A 720 mV peak,
1 ms recovery
Rev. 06.18.10_139
NFS110-M Series
4 of 5
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
AC (J1) mating connector
Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478
or equivalent crimp terminals.
DC (J2) mating connector
Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478
or equivalent crimp terminals.
ALL DIMENSIONS IN INCHES (mm)
Optional
Power Fail
Detect Circuit
(Key = Pin 2)
Pin 1
6-32 UNC
(4PL)
PIN 1
1.00 0.005
(25.4)
Voltage Adjust
J2
J1
F1
L1
T1
C6
PIN 1
0.156
DIA. HOLE
(4PL)
5A, 250 VAC
0.475
0.010
(12.07)
1.55 0.005
(39.37)
3.35 0.015 (85.09)
1.80 (45.72) MAX
0.050 0.020
(1.27)
4.250
0.020
(107.95)
3.750
0.005
(95.25)
0.250
0.010
(6.35)
0.250
0.010
(6.35)
6.50 0.005 (165.1)
7.00 0.020 (177.8)
T1
Power fail detect signal (Note 8)
50ms≤T1≤200ms
T2 will vary with line and load
T3≥3ms
Pout: 110W
PFD output is an open collector which
willsink≤40mAinthelowstate.
HIGH
T1 T2
T3
4.75V
3.5V MIN
0-0.4 MAX
LOW
4.75V
5V OUTPUT
PFD SIGNAL
AC INPUT
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM
80W
20 CFM FORCED AIR COOLING
40W
55W
0W
11W 11W MINIMUM LOAD REQUIRED AT 230VAC
NATURAL
CONVECTION
COOLING
0C 10C 20C 30C 40C 50C 60C 70C
DERATING CURVE (See Notes 9, 10)
Output Power (Watts)
110W
N/C = no connection.
Pin Connections
J1 -7901PJ -7902PJ SINGLES
Pin 1 AC Ground AC Ground AC Ground
Pin 2 AC Neutral AC Neutral AC Neutral
Pin 3 AC Line AC Line AC Line
J2
Pin 1 +5.1 V +5.1 V Vout
Pin 2 +5.1 V +5.1 V Vout
Pin 3 +5.1 V +5.1 V Vout
Pin 4 Return Return Return
Pin 5 Return Return Return
Pin 6 Return Return Return
Pin 7 Return Return Return
Pin 8 +12 V +12 V Vout
Pin 9 +12 V +12 V Vout
Pin 10 PFD PFD N/C
Pin 11 -12 V -12 V N/C
Pin 12 Removed for Key
Pin 13 -5 V +24 V N/C
Mechanical Notes
A Metallic or non-metallic stand-offs (maximum diameter 5.4mm) can be
used in all four mounting holes without effecting safety approval.
B The ground pad of the mounting hole near J1, allows system grounding
through a metal stand-off to the system chassis.
C The heat sink is grounded, and allows system grounding by mechanical
connection to the system chassis.
D The supply must be mechanically supported using the PCB mounting
holes and may be additionally supported by the heatsink mounting
holes.
E It is always advisable to attach the power supply heat sink to another
thermaldissipator(suchasachassisornnedheatsinketc).The
resulting decrease in heat sink mounted component temperatures will
improve power supply lifetime.
F A standard L-bracket and cover is available for mounting which contains
all screws, connectors and necessary mounting hardware. The kit is
available, order part number “NFS110CJ” .
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Embedded Power for
Business-Critical Continuity
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2010 Emerson Electric Co.
EmersonNetworkPower.com
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Connectivity
DC Power
Rev. 06.18.10_139
NFS110-M Series
5 of 5
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Artesyn Embedded Technologies:
NFS110-7604PJ NFS110-7901PJ NFS110-7902PJ NFS110-7912J