Preface Contents SICAM I/O Unit 7XV5673 IEC 61850 PIXIT, PICS, TICS V02.16 Manual E50417-C1040-C484-A2 Applications IEC 61850 Conformance Statements 1 2 Preface Purpose of this manual In this manual you will find the specification of the applications of the IEC 61850 interface. Target audience This manual is intended mainly for all persons who configure, parameterize and operate a SICAM I/O Unit device. Scope of validity SICAM I/O Unit V02.16 and higher. This manual is valid for SICAM I/O Unit devices running Edition 1 or Edition 2 mode of IEC 61850. Standards This manual has been created according to the ISO 9001 quality standards. SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 3 Contents 1 2 Applications ................................................................................................................................................ 7 1.1 General ........................................................................................................................................ 8 1.2 Association model........................................................................................................................ 9 1.3 Server model ............................................................................................................................. 10 1.4 Data set model........................................................................................................................... 10 1.5 Substitution model ..................................................................................................................... 10 1.6 Setting group control model ....................................................................................................... 10 1.7 Reporting model ........................................................................................................................ 10 1.8 Logging model ........................................................................................................................... 11 1.9 GOOSE publish model .............................................................................................................. 11 1.10 GOOSE subscribe model........................................................................................................... 12 1.11 Control model ............................................................................................................................ 14 1.12 Time and time synchronization model ....................................................................................... 16 1.13 File transfer model ..................................................................................................................... 17 1.14 Service tracking model .............................................................................................................. 17 1.15 TICS - Technical Issues Implementation Conformance Statement ........................................... 18 1.15.1 TISSUES Edition 1 ............................................................................................................... 18 1.15.2 TISSUES Edition 2 ............................................................................................................... 19 IEC 61850 Conformance Statements ...................................................................................................... 23 2.1 Definition of the Communication Services acc. to Standard (PICS) ........................................... 24 SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 5 1 Applications Contents This chapter specifies the protocol implementation extra information for testing (PIXIT) of the IEC 61850 interface in SICAM I/O Unit. 1.1 General 8 1.2 Association model 9 1.3 Server model 10 1.4 Data set model 10 1.5 Substitution model 10 1.6 Setting group control model 10 1.7 Reporting model 10 1.8 Logging model 11 1.9 GOOSE publish model 11 1.10 GOOSE subscribe model 12 1.11 Control model 14 1.12 Time and time synchronization model 16 1.13 File transfer model 17 1.14 Service tracking model 17 1.15 TICS - Technical Issues Implementation Conformance Statement 18 SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 7 Applications 1.1 General 1.1 General This manual specifies the protocol implementation extra information for testing (PIXIT) of the IEC 61850 interface in SICAM I/O Unit. It is based on the service subset definition given in the protocol implementation conformance (PICS), which is specified within the user manual SICAM I/O Unit IEC 61850. The following applicable ACSI service models are supported and specified: Association model Server model Data set model Reporting model GOOSE publish model GOOSE subscribe model Control model Time and time synchronization model Together with the PICS the PIXIT forms the basis for a conformance test according to IEC 61850-10. 8 SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 Applications 1.2 Association model 1.2 ID As1 Association model Ed 1 Description Maximum number of clients that can set-up Value / Clarification 6 an association simultaneously As2 1,2 TCP_KEEPALIVE value. The recommended range is 1 s to 20 s 10 seconds Adjustable under "Configuration Modbus TCP" As3 1,2 Lost connection detection time 30 seconds As5 1,2 What association parameters are necessary for successful association? Transport selector Y Session selector Y Presentation selector Y AP Title Y (ANY) AE Qualifier Y (ANY) Where Y means: as defined within the ICD file ANY means: any value accepted As6 As7 As8 1,2 1,2 1,2 If association parameters are necessary for association, describe the correct values Transport selector 0001 Session selector 0001 Presentation selector 00000001 What is the maximum and minimum MMS PDU size? Max MMS PDU size 20000 Min MMS PDU size 8192 What is the maximum start up time after a power supply interrupt? 30 seconds SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 9 Applications 1.3 Server model 1.3 Server model ID Ed Sr1 1,2 Which analogue value (MX) quality bits are supported (can be set by server)? N/A (there are no analogue values in the device) Sr2 1,2 Which status value (ST) quality bits are supported (can be set by server)? Validity: Good Invalid Reserved Questionable BadReference Oscillatory Failure OldData Inconsistent Inaccurate Y Y N N Y N Y N N N Source: Process Substituted Test OperatorBlocked Y N Y N 1.4 Description Value / Clarification Data set model No additional information. See Services section in SCL files. 1.5 Substitution model Substitution model is not supported by the device. 1.6 Setting group control model Setting Group control model is not supported by the device. 1.7 10 Reporting model SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 Applications 1.8 Logging model ID Ed Description Value / Clarification Rp1 1 The supported trigger conditions are (compare PICS) Integrity Data change Quality change Data update General Interrogation Y Y Y Y Y Rp2 1 The supported optional fields are Sequence-number Report-time-stamp Reason-for-inclusion Data-set-name Data-reference Buffer-overflow for Buffered report EntryID - for Buffered report Conf-rev Segmentation Rp3 1,2 Can the server send segmented reports? Y Rp4 1,2 Mechanism on second internal data change notification of the same analogue data value within buffer period (Compare IEC 61850-7-2 $14.2.2.9) Send report immediately Rp5 1 Multi client URCB approach N/A (only BRCB used) Y Y Y Y Y Y Y Y Y (Compare IEC 61850-7-2 14.2.1) Rp7 1,2 What is the buffer size for each BRCB or how many reports can be buffered? No fixed size, depends on total number of BRCBs Rp9 1 May the reported data set contain: - structured data objects? - data attributes? Y N/A (datasets are fix) Rp10 1,2 What is the scan cycle for binary events? 2 ms if binary inputs are used to generate binary events. Is this fixed, configurable? Fixed Rp11 1 Does the device support to pre-assign a RCB to a specific client in SCL? N Rp12 2 After restart of the server is the value of ConfRev restored from the original configuration or retained prior to restart? Restored from original configuration (ConfRev is fix) 1.8 Logging model Logging model is not supported by the device. 1.9 GOOSE publish model SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 11 Applications 1.10 GOOSE subscribe model ID Ed Gp1 1,2 Can the test flag in the published GOOSE be turned on / off? Description N Value / Clarification Gp2 1 What is the behavior when the GOOSE publish configuration is incorrect? GOOSE Publisher cannot be configured incorrect. Default values are used. Initially GOOSE Publishers are disabled. Gp3 1,2 Published FCD supported common data classes are SPS Arrays are not supported Gp4 1,2 What is the slow retransmission time? Is it fixed or configurable? MinTime can be configured by SCD file or via Web server. After a state change the repetition time is the following: Repetition time (min) = MinTime * (2^n) n = repetition index First repetition starts with n = 0. Repetition time will be increased until MaxTime is reached. When MaxTime is reached, the repetition time is the following: Repetition time (max) = MaxTime Gp5 2 What is the fast retransmission scheme? Is it fixed or configurable? Configured by SCD file or via Web server Gp7 1,2 What is the initial GOOSE sqNum after restart? sqNum = 0 Gp8 1 May the GOOSE data set contain: - structured data objects (FCD)? - Timestamp data attributes? N/A (datasets are fix) N/A (datasets are fix) additional items: 1,2 1.10 12 Which TAL (time allowed to live) value is sent by the GOOSE Publishers? 1.5 MaxTime GOOSE subscribe model SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 Applications 1.10 GOOSE subscribe model ID Ed Gs1 1,2 What elements of a subscribed GOOSE header are checked to decide the message is valid and the allData values are accepted? If yes, describe the conditions. Note: the VLAN tag may be removed by a ethernet switch and should not be checked Source MAC address Destination MAC address Ethertype = 0x88B8 APPIP gocbRef timeAllowedtoLive datSet goID t stNum sqNum test/sim confRev ndsCom numDatSetEntries Gs2 1 When is a subscribed GOOSE marked as lost? (TAL = time allowed to live value from the last received GOOSE message) When message does not arrive by 1 TAL Gs3 1,2 What is the behavior when one or more subscribed GOOSE message isn't received or syntactically incorrect? (missing GOOSE) Last received data as mark as invalid Gs4 1,2 What is the behavior when a subscribed GOOSE message is out-of-order? When a given state Number n, sequence Number l is received, only the following telegrams will be accepted: n, l+1; n, l+2; n+1, 0; n+1,1, 1,0 All other telegrams are ignored Gs5 2 What is the behavior when a subscribed GOOSE message is duplicated ? The repetition will be ignored Gs6 1 Does the device subscribe to GOOSE messages with/without the VLAN tag? with the VLAN tag without the VLAN tag Gs7 1 May the GOOSE data set contain: - structured data objects? - timestamp data attributes? N N Subscribed FCD supported common data classes are SPC, SPS, ACT Arrays are not supported Gs8 1,2 Description SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 Value / Clarification N Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y 13 Applications 1.11 Control model 1.11 Control model ID Ed Description Ct2 1,2 Is the control model fixed, configurable and/or dynamic? Fixed Value / Clarification Ct5 1 What is the behavior of the DUT when the test attribute is set in the SelectWithValue and/or Operate request? Y if own behavior is in test. The request will be proceed if the Beh of the logical node where the controlled object is located is Test. Otherwise the device will respond with "temporarily-unavailable". Ct8 1 What is the behavior of the DUT when the check conditions are set? Synchrocheck N/A Interlock-check N/A No check is performed. The Check bits will be ignored. Controllable objects are not representing equipement. Is this behavior fixed, configurable, online changeable? Fixed Ct9 1,2 Which additional cause diagnoses are supported? N/A Only direct-with-normal-security is supported, no additional cause. Ct10 1,2 How to force a "test-not-of" respond with SelectWithValue request? SelectWithValue is not supported Ct11 1,2 How to force a "test-not-of" respond with Selected request? Select is not supported Ct12 1,2 How to force a "test-not-of" respond with Operate request? DOns: Test and logical node Beh do not match (test mode is not supported) SBOns: N/A DOes: N/A SBOes: N/A Ct13 1,2 Which origin categories are supported / accepted? Bay-control Station-control Remote-control Automatic-bay Automatic-station Automatic-remote Maintenance Process Ct14 1,2 What happens if the orCat value is not supported or invalid? DOns: oper.Resp-, object-access-unsupported (9) SBOns: N/A DOes: N/A SBOes: N/A Ct15 1,2 Does the IED accept a SelectWithValue / Operate with the same control value as the current status value? DOns: SBOns: DOes: SBOes: Is this behaviour configurable? 14 Y Y Y Y Y Y Y Y Y N/A N/A N/A N SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 Applications 1.11 Control model ID Ed Description Value / Clarification Ct16 1 Does the IED accept a select/operate on the same control object from 2 different clients at the same time? DOns: N SBOns: N/A DOes: N/A SBOes: N/A It will lead to a negative response. Ct17 1 Does the IED accept a select/selectwithvalue from the same client when the control object is already selected (tissue 334)? N/A Ct18 1,2 Is for SBOes the internal validation performed during the SelectWithValue and/or Operate step? N/A Ct20 1,2 Does the IED support local / remote operation? N Ct21 1,2 Does the IED send an InformationReport with LastApplError as part of the Operate response- for control with normal security? SBOns: DOns: N/A N Ct22 2 How to force a "parameter-change-in-execution"? SBOns: SBOes: N/A N/A SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 15 Applications 1.12 Time and time synchronization model 1.12 Time and time synchronization model ID Ed Tm1 1,2 What time quality bits are supported (may be set by the IED)? Description LeapSecondsKnown ClockFailure ClockNotSynchronized Value / Clarification Tm2 1,2 Describe the behaviour when the time server(s) ceases to respond On one time server: Time quality is set to ClockNotSynchronized and ClockFailure. Y Y Y On all time servers: Time quality is set to ClockNotSynchronized and ClockFailure. Configurable from 2 - 120 minutes What is the time server lost detection time? (default 10 minutes) Tm3 1,2 How long does it take to take over the new time from time server? Max. 60 seconds Tm4 1,2 When is the time quality bit "ClockFailure" set? At faulty internal clock or failure of the synchronization source (SNTP, field bus) or RTC failure Tm5 1,2 When is the time quality bit "ClockNotSynchronized" set? When connection to all time servers is lost (see PIXIT-Tm2) Tm7 1 Does the device support time zone and daylight saving? Y Tm8 1,2 Which attributes of the SNTP response packet are validated? Leap indicator not equal to 3 Mode is equal to SERVER OriginateTimestamp is equal to value sent by the SNTP client as Transmit Timestamp RX/TX timestamp fields are checked for reasonableness SNTP version 3 and/or 4 other (describe) Tm9 16 1,2 Do the COMTRADE files have local time or UTC time and is this configurable? Y N N Y N N No COMTRADE files available SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 Applications 1.13 File transfer model 1.13 File transfer model File transfer model is not supported by the device. 1.14 Service tracking model Service tracking model is not supported by the device. SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 17 Applications 1.15 TICS - Technical Issues Implementation Conformance Statement 1.15 TICS - Technical Issues Implementation Conformance Statement 1.15.1 TISSUES Edition 1 The implemented TISSUES are only relevant when the Edition Setting is set to Edition 1. Part 7-2 Tissue Description 30 Control parameter T Y 49 BRCB TimeOfEntry? Y 52 Ambiguity GOOSE SqNum Y 190 BRCB: EntryId and TimeOfEntry Y 191 BRCB: Integrity and buffering reports Y 234 New type CtxInt Y 275 Confusing statement on GI usage Y 278 EntryId not valid for a server Y 297 Sequence number Y 298 Type of SqNum Y 300 Attribute Resv in BRCB Y 322 Write Configuration attribute of BRCBs Y 329 Reporting and BufOvl Y 332 Ambiguity in use of trigger options Y 335 Clearing of Bufovfl Y 348 URCB class and report 349 BRCB TimeOfEntry has two definitions Y 453 Reporting & Logging model revision Y 474 GI for URCB Part 8-1 Tissue 18 Implemented? N/A N/A Description Implemented? 116 GetNameList with empty response? Y 120 Type - Mod.stVal and Mod.ctlVal Y 165 Improper Error Response for GetDataSetValues Y 168 Order of attributes in MMS components Y 177 Ignoring OptFlds bits for URCB Y 183 GetNameList error handling Y 301 SqNum in Buffered Reports Y 344 TimeOfEntry misspelled Y 377 DeleteDataSet response- Y 422 Order of extension data objects and data attributes Y 433 Order of attributes in specialized CDCs for control service mapping Y 438 EntryTime base should be GMT Y SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 Applications 1.15 TICS - Technical Issues Implementation Conformance Statement 1.15.2 TISSUES Edition 2 Below tables give an overview of the mandatory Edition 2 Tissues. Part 6 Tissue Description Implemented? 658 Tracking related features N/A 663 FCDA element cannot be a "functionally constrained logical node" N/A 668 Autotransformer modeling N/A 687 SGCB ResvTms N/A 719 ConfDataSet - maxAttributes definition is confusing N/A 721 Log element name N/A 768 bType VisString65 is missing 779 object references N/A 788 SICS S56 from optional to mandatory N/A 789 ConfLdName as services apllies to both server and client 804 valKind and IED versus System configuration N/A 806 Max length of log name inconsistant between -6 and -7-2 N/A 807 Need a way to indicate if "Owner" present in RCB N/A 822 Extension of IED capabilities N/A 823 ValKind for structured data attributes N/A 824 Short addresses on structured data attributes N/A 825 Floating point value N/A 845 SGCB ResvTms N/A 853 SBO and ProtNs N/A 855 Recursive SubFunction N/A 856 VoltageLevel frequency and phases N/A 857 Function/SubFunction for ConductingEquipment N/A 886 Missing 8-1 P-types N/A 901 tServices as AP or as IED element N/A 936 SupSubscription parameter usage is difficult N/A 1168 doName and daName of ExtRef N/A 1175 IPv6 address lowercase only N/A Part 7-1 Tissue Y Description Y Implemented? 828 Data model namespace revision 1129 Rules for extending nameplate information N/A 1151 simulated GOOSE disappears after 1st appearance when LPHD.Sim = TRUE N/A 1196 Extensions to standardized LN classes made by third parties N/A Part 7-2 Tissue Y Description Implemented? 778 AdCause values 780 What are 'unsupported trigger option at a control block? 783 TimOper Resp- N/A 786 AddCause values N/A SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 N/A Y 19 Applications 1.15 TICS - Technical Issues Implementation Conformance Statement Part 7-2 Tissue Description 820 Mandatory ACSI services 858 typo in enumeration ServiceType N/A 861 dchg of ConfRev attribute N/A 876 GenLogiclNodeClass and SGCB, GoCB, MsvCB, UsvCB N/A 1038 Loss of Info Detection After Resynch N/A 1050 GTS Phycomaddr definition in SCL example N/A 1062 Entrytime not used in CDC N/A 1071 Length of DO name N/A 1091 The sentence "The initial value of EditSG shall be 0", has to be stated in part 7.2 not in 8.1 N/A 1127 Missing owner attribute in BTS and UTS N/A 1163 Old report in URCB N/A 1202 GI not optional Part 7-3 Tissue Y Y Description Implemented? 697 Persistent command / PulseConfig N/A 698 Wrong case is BAC.dB attribute N/A 722 Units for 'h' and 'min' not in UnitKind enumeration. N/A 919 Presence Condition for sVC N/A 925 Presence of i or f attribute - Problem with writing N/A 926 Presence Conditions within RangeConfig N/A Part 7-4 Tissue 20 Implemented? Description Implemented? 671 Mistake in definition of Mod & Beh 674 CDC of ZRRC.LocSta is wrong N/A Y 676 Same data object name used with different CDC N/A 677 MotStr is used with different CDC in PMMS and SOPM LN classes N/A 679 Remove CycTrMod Enum N/A 680 SI unit for MHYD.Cndct N/A 681 Enum PIDAlg N/A 682 ANCR.ParColMod N/A 683 Enum QVVR.IntrDetMth N/A 685 Enum ParTraMod N/A 686 New annex H - enums types in XML 694 Data object CmdBlk N/A 696 LSVS.St (Status of subscription) N/A 712 Interpretation of quality operatorBlocked N/A 713 DO Naming of time constants in FFIL N/A 724 ANCR.Auto N/A 725 Loc in LN A-group N/A 734 LLN0.OpTmh vs. LPHD.OpTmh N/A Y SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 Applications 1.15 TICS - Technical Issues Implementation Conformance Statement Part 7-4 Tissue Description Implemented? 736 PFSign N/A 742 GAPC.Str, GAPC.Op and GAPC.StrVal N/A 743 CCGR.PmpCtl and CCGR.FanCtl N/A 744 LN STMP, EEHealth and EEName N/A 773 Loc, LocKey and LocSta YPSH and YLTC N/A 774 ITCI.LocKey N/A 800 Misspelling in CSYN N/A 802 CCGR and Harmonized control authority N/A 808 Presence condition of ZMOT.DExt and new DOs N/A 831 Setting of ConfRevNum in LGOS N/A 838 Testing in Beh=Blocked N/A 844 MFLK.PhPiMax, MFLK.PhPiLoFil, MFLK.PhPiRoot DEL->WYE N/A 849 Presence conditions re-assessing in case of derived statistical calculation N/A 877 QVUB -seetings should be optional N/A 909 Remove ANCR.ColOpR and ColOpL N/A 912 Clarification of PwrRtg/VARtg N/A 920 Resetable Counter is NOT resetable N/A 932 Rename AVCO.SptVol to AVCO.VolSpt N/A 939 Change CDC for ANCR.FixCol N/A 991 LGOS: GoCBRef (as well as LSVS.SvCBRef) should be mandatory N/A 1007 PTRC as fault indicator - Update of description required N/A 1044 TapChg in AVCO N/A 1077 Rename DOnames within LTIM N/A Note: Tissues 675, 735, 772, 775, 776, 878 are not relevant for conformance testing. Part 8-1 Tissue Description Implemented? 784 Tracking of control (CTS) N/A 817 Fixed-length GOOSE float encoding N/A 834 File dir name length N/A 951 Encoding of Owner attribute N/A 1040 Associate error code N/A 1178 TABLE 84 Specifies incorrect Select Positive Result value N/A Compare the IEC 61850 Tissue Database for more details: www.tissues.iec61850.com SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 21 2 IEC 61850 Conformance Statements Contents This chapter describes conformity with IEC 61850. It does not describe the entire standard but only parts in which there is a choice in the services. 2.1 Definition of the Communication Services acc. to Standard (PICS) SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 24 23 IEC 61850 Conformance Statements 2.1 Definition of the Communication Services acc. to Standard (PICS) 2.1 Definition of the Communication Services acc. to Standard (PICS) The tables in the section below appear in the same sequence as in standard IEC 61850, Part 8-1, Section 24. The tables refer to Part 7 of the standard and the corresponding information must be contained in the PICS. This section describes the conformance statements. The standard groups them together under the term Protocol Implementation Conformance Statement (PICS). Mandatory Services Please note that a number of services are prescribed and must be implemented to comply with the standard. Only the optional services and protocols are listed here because they constitute freedom of implementation. None of the mandatory services is explicitly explained here. Please refer to the standard IEC 61850, Part 8-1. The description below refers to implementation in the SICAM I/O Unit device. The tables give the names stated in the standard. Basic Conformance Statement Client/ Subscriber Server/ Publisher Value/ Comments Client-Server roles B11 Server side (of TWO-PARTY-APPLICATION-ASSOCIATION) Y B12 Client side (of TWO-PARTY-APPLICATION-ASSOCIATION) N SCSMs supported B21 SCSM: IEC 6185-8-1 used N Y B22 SCSM: IEC 6185-9-1 used N N B23 SCSM: IEC 6185-9-2 used N N B24 SCSM: other N/A N/A Generic substation event model (GSE) B31 Publisher side Y B32 Subscriber side Y Transmission of sampled value model (SVC) B41 Publisher side N B42 Subscriber side N Y = supported N or empty = not supported 24 SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 IEC 61850 Conformance Statements 2.1 Definition of the Communication Services acc. to Standard (PICS) ACSI Models Conformance Statement Client/ Subscriber Server/ Publisher Value/Comments If Server side (B11) and/or Client side (B12) supported M1 Logical device N Y M2 Logical node N Y M3 Data N Y M4 Data set N Y M5 Substitution N N M6 Setting group control N N Reporting M7 Buffered report control N Y M7-1 sequence-number N Y M7-2 report-time-stamp N Y M7-3 reason-for-inclusion N Y M7-4 data-set-name N Y M7-5 data-reference N Y M7-6 buffer-overflow N Y M7-7 entryID N Y M7-8 BufTm N Y M7-9 IntgPd N Y GI N Y N N M7-10 M8 Unbuffered report control M8-1 sequence-number N N M8-2 report-time-stamp N N M8-3 reason-for-inclusion N N M8-4 data-set-name N N M8-5 data-reference N N M8-6 BufTm N N M8-7 IntgPd N N GI N N N N N N M8-8 Logging M9 Log control M9-1 N N M10 Log N N M11 Control N Y IntgPd If GSE (B31/32) is supported M12 GOOSE Y Y M13 GSSE N N If SVC (41/42) is supported M14 Multicast SVC N N M15 Unicast SVC N N If Server or Client side (B11/12) supported M16 Time Y N M17 File Transfer N N SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 25 IEC 61850 Conformance Statements 2.1 Definition of the Communication Services acc. to Standard (PICS) Client/ Subscriber Server/ Publisher Value/Comments Y = supported N or empty = not supported ACSI service conformance statement Services AA:TP/MC Client (C) Server (S) Comments Server S1 GetServerDirectory(LOGICAL-DEVICE) TP N Y Application association S2 Associate N Y S3 Abort N Y S4 Release N Y TP N Y Logical device S5 GetLogicalDeviceDirectory Logical node S6 GetLogicalNodeDirectory TP N Y S7 GetAllDataValues TP N Y S8 GetDataValues TP N Y S9 SetDataValues TP N N S10 GetDataDirectory TP N Y S11 GetDataDefinition TP N Y S12 GetDataSetValues TP N Y S13 SetDataSetValues TP N N S14 CreateDataSet TP N N S15 DeleteDataSet TP N N S16 GetDataSetDirectory TP N Y TP N N Data Data set Substitution S17 SetDataValues Setting group control S18 SelectActiveSG TP N N S19 SelectEditSG TP N N S20 SetSGValues TP N N S21 ConfirmEditSGValues TP N N S22 GetSGValues TP N N S23 GetSGCBValues TP N N Reporting Buffered report control block (BRCB) 26 SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 IEC 61850 Conformance Statements 2.1 Definition of the Communication Services acc. to Standard (PICS) Services S24 AA:TP/MC Report TP Client (C) Server (S) N Y S24-1 data-change (dchg) N Y S24-2 quality-change (qchg) N Y S24-3 data-update (dupd) N Y S25 GetBRCBValues TP N Y S26 SetBRCBValues TP N Y TP Comments Unbuffered report control block (URCB) N N S27-1 data-change (dchg) N N S27-2 quality-change (qchg) N N S27-3 data-update (dupd) N N S27 Report S28 GetURCBValues TP N N S29 SetURCBValues TP N N Logging Log control block S30 GetLCBValues TP N N S31 SetLCBValues TP N N S32 QueryLogByTime TP N N S33 QueryLogAfter TP N N S34 GetLogStatusValues TP N N Log Generic substation event model (GSE) GOOSE-CONTROL-BLOCK S35 SendGOOSEMessage MC N Y S36 GetGoReference TP N N S37 GetGOOSEElementNumber TP N N S38 GetGoCBValues TP N Y S39 SetGoCBValues TP N Y GSSE-CONTROL-BLOCK S40 SendGSSEMessage MC N N S41 GetGsReference TP N N S42 GetGSSEDataOffset TP N N S43 GetGsCBValues TP N N S44 SetGsCBValues TP N N Transmission of sampled value model (SVC) Multicast SVC S45 SendMSVMessage MC N N S46 GetMSVCBValues TP N N S47 SetMSVCBValues TP N N Unicast SVC S48 SendUSVMessage TP N N S49 GetUSVCBValues TP N N SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019 27 IEC 61850 Conformance Statements 2.1 Definition of the Communication Services acc. to Standard (PICS) Services AA:TP/MC Client (C) Server (S) SetUSVCBValues TP N N S51 Select TP N N S52 SelectWithValue TP N N S53 Cancel TP N N S54 Operate TP N Y S55 CommandTermination TP N N S56 TimeActivatedOperate TP N N S50 Comments Control File transfer S57 GetFile TP N N S58 SetFile TP N N S59 DeleteFile TP N N S60 GetFileAttributeValues TP N N Time T1 Time resolution of internal clock 10 (1 ms) Time accuracy of internal clock +-5 ms T0 (n = 7) Nearest negative power of 2 in seconds T0 (10 ms), T1 (1 ms), T2 T3 28 Supported TimeStamp resolution 10 (1ms) T2 (100 s), T3 (25 s), T4 (4 s), T5 ( 1s) Nearest negative power of 2 in seconds SICAM I/O Unit, 7XV5673, PIXIT, PICS, TICS, Manual E50417-C1040-C484-A2, Release 01.2019