Photoelectric Sensor with Separate Digital Amplifier (Laser-type) E3C-LDA CSM_E3C-LDA_DS_E_4_1 Variable Laser Beam for Spot, Line, or Area Detection * Long-distance detection (diffuse reflective: 1 m, retro-reflective: 7 m). * Beam shape selectable from spot, line, and area types to match various applications. * Adjustable spot diameter. * Adjustable optical axis. * The E3DC-LDA0, which supports the EtherCAT Sensor Communications Unit and the CompoNet Sensor Communications Unit, is also included in product lineup. Refer to Safety Precautions on page 9. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Features Diffuse Reflective Model All three beam types provide ample long-distance detection of 1,000 mm. Three beam types means a wider variety of applications. Spot, Line, and Area Types At 1,000 mm: Minimum spot diameter of 950 m Suitable for various applications without any additional costs. Variable Focal Point Mechanism Mount Beam Units to a Spot Type Sensor to convert to Line or Area Type. Optical axis alignment range: Approximately 2 Spot Type E3C-LD11 Sensing distance of 1 m. Spot diameter can be adjusted to enable ultra-high-precision positioning. Optical Axis Adjustment Mechanism The sensor detection point can be easily changed. 8 mm - 0.2 mm - 3.5 mm (VR minimum) (VR median) (VR maximum) 7 mm - 28.5 mm - 33 mm At distance of 150 mm (VR minimum) (VR median) (VR maximum) Line Type E3C-LD21 5 to 15 mm (VR minimum) (VR maximum) 5 to 33 mm At distance of 150 mm (VR minimum)(VR maximum) Area Type E3C-LD31 Coaxial Retroreflective Model Easy Sensor Installation and Sensing Characteristics Equivalent to Through-beam Sensors. Sensing distance of 7 m. Variable Focal Point Mechanism Optical axis alignment range: Approximately 1 to1.5 Optical Axis Adjustment Mechanism At 1 m: Minimum spot diameter of 0.8 mm E39-R13 Spot, Line, and Area Types Spot Type Coaxial Optical System E3C-LR11 The coaxial optical system and laser beam allow high-precision detection. The built-in MSR Function inhibits the effect of reflected light from the workpiece. 1 E3C-LDA Ordering Information Sensor Heads (Dimensions page 12, 13) Sensing method Appearance Diffuse-reflective Beam shape Model Remarks Spot (variable) E3C-LD11 2M Mounting a Beam Unit (sold separately) allows the use of line and area beams. Line (variable) E3C-LD21 2M This model number is for the set consisting of the E39-P11 mounted to the E3C-LD11. Area (variable) Spot (variable) Coaxial Retro-reflective E3C-LD31 2M E3C-LR11* 2M Spot (2.0-mm fixed dia.) This model number is for the set consisting of the E39-P21 mounted to the E3C-LD11. Mounting a Beam Unit (order separately) enables the use of line and area beams. E3C-LR12* 2M --- * Select a Reflector (order separately) according to the application. Amplifier Units Pre-wired Amplifier Units (Dimensions page 14) Item Appearance Model Functions Externalinput models Twin-output Advanced models models ATC function Analog output NPN output PNP output Remote setting Counter Differential operation E3C-LDA21 2M E3C-LDA51 2M Area output Self-diagnosis Differential operation E3C-LDA11 2M E3C-LDA41 2M ATC (Active Threshold Control) E3C-LDA11AT 2M E3C-LDA41AT 2M Analog output E3C-LDA11AN 2M E3C-LDA41AN 2M Amplifier Units with Wire-saving Connectors (A Wire-saving Connector (sold separately) is required.) (Dimensions page 15, 16) Item Appearance Model Functions Externalinput models Advanced Twin-output models models ATC function NPN output PNP output Remote setting Counter Differential operation E3C-LDA7 * E3C-LDA9 * Area output Self-diagnosis Differential operation E3C-LDA6 * E3C-LDA8 * E3C-LDA6AT E3C-LDA8AT ATC (Active Threshold Control) * These models allow you to use an E3X-DRT21-S VER.3 Sensor Communications Unit. When using the E3X-DRT21-S VER.3, use an E3X-CN02 Connector without a Cable for the Wire-saving Connector. Amplifier Unit with Connector for Sensor Communications Unit (for EtherCAT and CompoNet) (Dimensions page 16) Item Appearance Functions Model Applicable Sensor Commuincations Unit E3X-ECT Advanced Twin-output models models Area output Self-diagnosis Differential operation E3C-LDA0 E3X-CRT Accessories (Order Separately) Wire-saving connectors (Required for models for Wire-saving Connectors.) *Protective stickers: provided. (Dimensions E3X-DA-S/MDA) Item Appearance Cable length No. of conductors Model 4 E3X-CN21 2 E3X-CN22 Master Connector 2m Slave Connector Ordering Precaution for Amplifier Units with Wire-saving Connectors Amplifier Units and Connectors are sold separately. Refer to the following tables when placing an order. Amplifier Unit NPN output PNP output E3C-LDA6 E3C-LDA8 Advanced E3C-LDA7 E3C-LDA9 models E3C-LDA6AT E3C-LDA8AT When Using 5 Amplifier Units Applicable Connector (order separately) Master Connector Slave Connector Model 5 Amplifier Units + + E3X-CN21 1 Master Connector E3X-CN22 4 Slave Connectors 2 E3C-LDA Mobile Console (Dimensions E3X-DA-S/MDA) Appearance Model Remarks Mobile Console with Head, E3X-MC11-SV2 Cable, and AC adapter (model number of set) provided as accessories E3X-MC11-C1-SV2 Mobile Console E3X-MC11-H1 Head E39-Z12-1 Cable (1.5 m) Note: Use the E3X-MC11-S Mobile Console for the E3X-LDA Series Amplifier Units. The E3X-MC11-SV2 is an upgraded version of the E3X-MC11-S that is fully interchangeable with the older model. Refer to E3X-DA-S/MDA for details. Beam Unit (for E3C-LD11/LR11) A Beam Unit is not provided with the Sensor and must be ordered separately as required. Applicable Sensor Head Appearance Beam shape Model Reflectors (Required when using retro-reflective models) A Reflector is not provided with the Sensor head. Be sure to order a Reflector separately. (Dimensions E39-L/E39-S/E39-R) Type Appearance Model Standard Effective area: 23 x 23 mm * E39-R12 Standard Effective area: 7 x 7 mm * E39-R13 Transparent object detection Effective area: 23 x 23 mm * E39-R14 Mounting Bracket Sheet (cuttable) Effective area: 195 x 22 mm E39-RS4 A Mounting Bracket is not provided with the Amplifier Unit and must be ordered separately as required. (Dimensions E39-L/E39-S/E39-R) Sheet (cuttable) Effective area: 108 x 46 mm E39-RS5 Line E39-P11 Area E39-P21 E3C-LD11 Line E39-P31 Area E39-P41 E3C-LR11 Appearance Model Quantity E39-L143 1 Note: For details, refer to Reflectors E39-L/E39-S/E39-R * Use a standard model (E39-R12/R13) if the distance from the Sensor is 400 mm or more. Use the short-distance model (E39-R14) if the distance is less than 400 mm. End Plate A End Plate is not provided with the Amplifier Unit and must be ordered separately as required. (Dimensions PFP-@) Appearance Model PFP-M Quantity 1 3 E3C-LDA Ratings and Specifications For dimensions, refer to pages 12 to 16. Sensor Heads Type Item Model Diffuse-reflective E3C-LD11 Coaxial Retro-reflective (with M.S.R. function) E3C-LD21 E3C-LD31 E3C-LR11 E3C-LR11+ E39-P31 E3C-LR11+ E39-P41 E3C-LR12 Light source (wavelength) 1 mW max. Red semiconductor laser diode (650 nm), 3 mW max. Red semiconductor laser diode (650 nm), 2.5 mW max. (JIS Class 1, (JIS Class 2, IEC/EN Class 2, and FDA Class 2) (JIS Class 2, IEC/EN Class 2, and FDA Class 2) IEC/EN Class 1, and FDA Class 2) Sensing distance High-resolution mode: 30 to 1,000 mm Standard mode: 30 to 700 mm Super-high-speed mode: 30 to 250 mm *1 7m 5m 2 m *2 1,700 mm 1,300 mm 700 mm *2 900 mm 700 mm 400 mm *2 7m 5m 2 m *2 Focus *3 0.8 mm max. 33 mm (at distances up (at 150 mm) to 300 mm) 0.8 mm max. (at distances up to 1,000 mm) 28 mm (at 150 mm) 28 x 16 mm (at 150 mm) 2.0-mm dia. (at distance up to 1,000 mm) Functions Variable focal point mechanism (focus adjustment) *4, optical axis adjustment mechanism (axis adjustment) Indicators LDON indicator: Green; Operation indicator: Orange 33 x 15 mm (at 150 mm) Ambient illumination Incandescent lamp: 3,000 lx (Receiver side) Ambient temperature Operating: -10 to 55C, Storage: -25 to 70C (with no icing or condensation) Ambient humidity Operating/storage: 35% to 85% (with no condensation) Insulation resistance 20 M min. at 500 VDC Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute Shock resistance Destruction: 300 m/s2 6 directions 3 times each (up/down, right/left, forward/backward) Vibration resistance Destruction: 10 to 150 Hz with double amplitude of 0.7 mm, in X, Y, and Z directions for 80 min each Degree of protection IP40 (IEC) Connection method Connector (standard cable length: 2 m) Materials Case and cover: ABS Front surface filter: Methacrylic resin Case and cover: ABS Front surface filter: Glass Weight (packed state) Approx. 85 g Approx. 100 g Accessories Instruction manual, Laser warning labels (English) IP40 (IEC 60529) *1. Sensing distance values are for white paper. *2. These sensing distance values apply when a E39-R12 Reflector is used. The MSR function is built-in. The reflected light from the object being measured may affect the sensing accuracy, so adjust the threshold value before use. *3. The beam radius is the value for the middle measurement distance and indicates a typical value for the middle sensing distance. The radius is defined by light intensity of 1/e2 (13.5%) of the central light intensity. Light will extend beyond the main beam and may be affected by conditions surrounding the object being measured. *4. The E3C-LR12 has a fixed beam size (the focal point cannot be changed). 4 E3C-LDA Amplifier Units Type External-input models Twin-output models Standard models Standard models Pre-wired Wire-saving connector Pre-wired Wire-saving connector Model NPN output E3C-LDA21 E3C-LDA7 E3C-LDA11 E3C-LDA6 PNP output E3C-LDA51 E3C-LDA9 E3C-LDA41 E3C-LDA8 Item Model for Sensor Communications Unit E3C-LDA0 *1 E3C-LDA11AT E3C-LDA6AT E3C-LDA11AN E3C-LDA41AT E3C-LDA8AT E3C-LDA41AN 1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC) Control output Standard models Pre-wired Power consumption Response time Standard models Wire-saving connector 12 to 24 VDC 10%, ripple (p-p) 10% max. Functions Analog-output models Pre-wired Supply voltage ON/OFF output ATC-output models Load power supply voltage: 26.4 VDC max.; NPN/PNP (depends on model) open collector Load current: 50 mA max.; residual voltage: 1 V max. Analog output Control output Voltage output: 1 to 5 VDC (connected load 10 k min.) Temperature characteristics 0.3% F.S./C Response time/ Repeat accuracy Super-highspeed mode: 100 s/4.0% F.S. High-speed mode: 250 s/ 4.0% F.S. Standard mode: 1 ms/2.0% F.S. High-resolution mode: 4 ms/ 2.0% F.S. --- Super-highspeed 80 s for operation and reset mode *2 100 s for operation and reset --- 100 s for operation and reset High-speed mode 250 s for operation and reset Standard mode 1 ms for operation and reset High-resolution mode 4 ms for operation and reset Differential detection Switchable between single edge and double edge detection mode. Single edge: Can be set to 250 s, 500 s, 1 ms, 10 ms, or 100 ms. Double edge: Can be set to 500 s, 1 ms, 2 ms, 20 ms, or 200 ms. Timer function Select from OFF-delay, ON-delay, or one-shot timer. 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1-s increments) Zero-reset Negative values can be displayed. Initial reset Settings can be returned to defaults as required. Mutual interference prevention Possible for up to 10 Units. *2 Counter Switchable between up counter and down counter. Set count: 0 to 9,999,999 I/O settings External input setting (Select from teaching, power tuning, zero reset, light OFF, or counter reset.) Digital display --- --Output setting (Select from channel 2 output, area output, or self-diagnosis.) Output setting (Select from channel 2 output, area output, self-diagnosis, or ATC error output.) Analog output setting (Offset voltage can be adjusted.) Select from digital incident level + threshold or six other patterns. Display orientation Switching between normal/reversed display is possible. Ambient temperature range *3 Operating: Groups of 1 to 2 Amplifiers: -25C to 55C, Groups of 3 to 10 Amplifiers: -25C to 50C, Groups of 11 to 16 Amplifiers: -25C to 45C Storage: -30C to 70C (with no icing) Ambient humidity range Operating and storage: 35% to 85% (with no condensation) Insulation resistance 20 M at 500 VDC Dielectric strength 1,000 VAC at 50/60 Hz for 1 min. Vibration resistance *4 Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance *5 Destruction: 500 m/s2, 3 times each in X, Y, and Z directions Degree of protection IP50 (IEC 60529) Connection method Pre-wired or wire-saving connector *6 Weight (packed state) Pre-wired Models: Approx. 100 g Wire-saving Connector Models: Approx. 55 g Sensor Communications Unit Connector Models: Approx. 55 g Materials Case Polybutylene terephthalate (PBT) Cover Polycarbonate *1. This model allows you to use an E3X-ECT EtherCAT Sensor Communications Unit or E3X-CRT CompoNet Sensor Communications Unit. *2. Communications are disabled if super-high-speed mode is selected, and the mutual interference prevention function and the communications function for the Mobile Console will not function. *3. The following temperature ranges apply when an E3X-ECT EtherCAT or E3X-CRT CompoNet Sensor Communications Unit is used with the E3C-LDA0: Groups of 1 or 2 Amplifier Units: 0 to 55C, Groups of 3 to 10 Amplifier Units: 0 to 50C, Groups of 11 to 16 Amplifier Units: 0 to 45C, Groups of 17 to 30 Amplifier Units (with the E3X-ECT): 0 to 40C. *4. The vibration resistance of the E3C-LDA0 is as follows: Destruction: 10 to 150 Hz with a 0.7-mm double amplitude for 80 min each in X, Y, and Z directions. *5. The shock resistance of the E3C-LDA0 is as follows: Destruction: 150 m/s2, 3 times each in X, Y, and Z directions. *6. A connector for a Sensor Communications Unit is used to connect the E3C-LDA0. 5 E3C-LDA Engineering Data (Reference Value) 1000 900 800 700 600 E3C-LR12 6 Beam diameter (mm) Beam diameter (mm) Beam diameter (m) Minimum Beam Diameter vs. Sensing Distance E3C-LD11 E3C-LR11 Y direction 5 X direction 4 3 500 5 4 3 Y direction 400 2 2 X direction 300 200 1 1 100 0 0 100 200 300 400 500 600 700 800 900 1000 1 2 3 4 5 Distance (mm) 220 160 (1) (2) (3) (4) (5) (6) 140 Y direction 200 180 X direction Y direction X direction Y direction X direction Y direction FOCUS control turned all the way to right FOCUS control turned to center FOCUS control turned all the way to left 0 1 2 3 4 5 6 7 Distance (m) E3C-LD31 (1) (3) 120 X direction 7 Distance (m) Beam shape X/Y (mm) Beam shape X/Y (mm) Beam Shape vs. Sensing Distance E3C-LD21 6 200 (1) (2) 180 (3) (4) 160 140 120 X direction Y direction X direction Y direction FOCUS control turned all the way to right FOCUS control turned all the way to left Y direction (1) X direction 100 100 80 80 60 60 (6) (2) 40 40 (5) 20 0 (2) 20 (4) 100 200 300 400 500 600 700 800 900 1000 Distance (mm) 0 (4) (3) 100 200 300 400 500 600 700 800 900 1000 Distance (mm) Note: The dashed lines indicate nonvisible regions of the beam shape. Differential travel (mm) Differential Travel vs. Sensing Distance E3C-LD 50 45 40 Super-high-speed mode Standard mode High-resolution mode Detected object: white paper 35 30 Differential travel Distance 25 ON OFF 20 15 10 5 0 200 400 600 800 1000 Distance (mm) 6 E3C-LDA I/O Circuit Diagrams NPN Output Model Operation mode Timing charts Mode selector switch Output circuit ch1/ Incident light ch2 No incident light Light-ON E3C-LDA11 E3C-LDA6 E3C-LDA11AT E3C-LDA6AT Operation Indicator (orange) Output transistor ON OFF ON OFF Operate Load (e.g., relay) Reset (Between brown and black leads) L-ON (LIGHT ON) Display Operation indicator (orange) ch1 Dark-ON Light-ON Incident light No incident light Operation ON Indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black leads) E3C-LDA21 E3C-LDA7 ON OFF ON OFF Operate Load (e.g., relay) Reset (Between brown and black leads) Load 12 to 24 VDC Control output 2 Blue L-ON (LIGHT ON) Dark-ON D-ON (DARK ON) Light-ON Incident light No incident light Operation ON Indicator OFF (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black leads) L-ON (LIGHT ON) Display Power tuning indicator (orange) Operation indicator (orange) Brown Black Photoelectric Sensor Main Circuit Load 12 to 24 VDC Control output Orange External input Blue E3C-LDA11AN Dark-ON Load Control output 1 Orange D-ON (DARK ON) Incident light No incident light Operation ON Indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between brown and black leads) Incident light No incident light Operation ON Indicator OFF (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black leads) Brown Black Photoelectric Sensor Main Circuit ch1/ Incident light ch2 No incident light Operation Indicator (orange) Output transistor Operation indicator (orange) ch2 Display Power tuning indicator (orange) Operation indicator (orange) Brown Load Black Photoelectric Sensor Main Circuit Control output 12 to 24 VDC Orange Analog output Load 10 k min. Blue D-ON (DARK ON) 7 E3C-LDA PNP Output Model Operation mode Timing charts Mode selector switch Light-ON ch1/ Incident light ch2 No incident light Operation ON Indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black leads) L-ON (LIGHT ON) E3C-LDA41 E3C-LDA8 E3C-LDA41AT E3C-LDA8AT Dark-ON Light-ON E3C-LDA51 E3C-LDA9 ch1/ Incident light ch2 No incident light Operation ON Indicator OFF (orange) ON OFF Operate Load (e.g., relay) Reset (Between blue and black leads) Output transistor Incident light No incident light Operation ON Indicator OFF (orange) ON Output transistor OFF Load Operate (e.g., relay) Reset (Between blue and black leads) Operation indicator (orange) ch2 Brown D-ON (DARK ON) L-ON (LIGHT ON) Control output 1 Black 12 to 24 VDC Control output 2 Load Blue Display Power tuning indicator (orange) Dark-ON Light-ON Incident light No incident light Operation ON Indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black leads) L-ON (LIGHT ON) Dark-ON Operation indicator (orange) ch1 Orange Load D-ON (DARK ON) Incident light No incident light Operation ON Indicator OFF (orange) ON Output transistor OFF Display Photoelectric Sensor Main Circuit Incident light No incident light Operation ON Indicator OFF (orange) ON Output transistor OFF Operate Load (e.g., relay) Reset (Between blue and black leads) E3C-LDA41AN Output circuit Operation indicator (orange) Brown External input Photoelectric Sensor Main Circuit Orange Black Blue Display Power tuning indicator (orange) Operation indicator (orange) Photoelectric Sensor Main Circuit Control output 12 to 24 VDC Load Brown Orange Black Blue Analog output Control output Load 12 to 24 VDC Load 10 k min. D-ON (DARK ON) Operate Load (e.g., relay) Reset (Between blue and black leads) 8 E3C-LDA Nomenclature Amplifier Units Twin Output Models (E3C-LDA11/LDA41/LDA6/LDA8/LDA0) External Input Models (E3C-LDA21/LDA51/LDA7/LDA9) Main Display (red) Sub-Display (green) Operation Keys Main Display (red) Sub-Display (green) Operation Keys Incident level, function, etc. Threshold, function settings, etc. Function setting operations Incident level, function, etc. Threshold, function settings, etc. Function setting operations UP UP DOWN DOWN MODE MODE Channel Selector Operation indicator indicator for channel 1 (orange) Operation for channel 2 (orange) ON when output is ON. OFF when output is OFF. ON when output is ON. OFF when output is OFF. Use to switch between the display and setting channels. Mode Selector Use to select SET or RUN mode. Operation Mode Selector Operation Indicator (orange) Power Tuning Indicator ON when output is ON. ON: Power tuning is set. OFF when output is OFF. Use to switch between Light ON and Dark ON modes. Mode Selector Use to select SET or RUN mode Safety Precautions Refer to the Photoelectric Sensors Technical Guide. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purpose. Never look into the laser beam. Doing so continuously will result in visual impairment. Precautions for Safe Use The following rules are required to ensure safety. Be sure to observe these rules. 1. Installation environment *Do not use in an environment where combustible or explosive gas is present. *To ensure safe operation and maintenance of the product, install it away from high-voltage devices and power devices. 2. Power supply and wiring *Do not exceed the rated voltage (12 to 24 VDC 10%). *Do not remove a connector while it is supplying power. This may damage the product. 3. Other points *Do not attempt to disassemble, repair, or modify the product. *When disposing of the product, treat it as industrial waste. 9 E3C-LDA Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Official laser safety measures have been established regarding laser devices both inside and outside of Japan. For details, refer to Laser Beam Safety Standards. Mounting Mounting and removing the sensor head 1. Open the protective cover. 2. With the locking lever on the sensor head connector facing up, insert the connector into the connector opening. Amplifier Units 1 Designing Operation after Turning Power ON The Amplifier Unit is ready to operate within 200 ms after the power supply is turned ON. If the Sensor and load are connected to power supplies separately, be sure to turn ON the power supply to the Sensor first. Cleaning Do not use thinner, benzene, acetone, or kerosene. If the filter on the front of the sensor becomes soiled with dust, oil droplets, or other materials, (a) Use a blower brush (used to clean camera lenses) to blow large dust particles from the surface. Do not blow the dust away with your mouth. (b) Use a soft cloth (for cleaning lenses) with a little alcohol to remove the remaining dust. Note: Do not use a scrubbing action when cleaning as a scratch on the filter could result in the Sensor malfunctioning. About the object Measurement may not be possible or may not be precise with some types of object materials and shapes (such as transparent objects, objects with extremely low reflectance, objects smaller than the beam diameter, objects with a large curvature, highly tilted objects, etc). 2 To remove the connector, press down on the locking lever and pull the connector out. Lock lever Connecting and Disconnecting Connectors (Mounting Connectors) 1. Insert the Master or Slave Connector into the Amplifier Unit until it clicks into place. Insert 2. Attach the protector seals (provided as accessories) to the sides of master and slave connectors that are not connected. Protective seal Power supply terminal for linking Note: Attach the seals to the sides with grooves. (Removing Connectors) 1. Slide the slave Amplifier Unit(s) for which the Connector is to be removed away from the rest of the group. 2. After the Amplifier Unit(s) has been separated, press down on the lever on the Connector and remove it. (Do not attempt to remove Connectors without separating them from other Amplifier Units first.) Press down Lever Remove 10 E3C-LDA Mounting and Removing Amplifier Units Beam shape adjustment function (Mounting Amplifier Units) 1. Mount the Amplifier Units one at a time onto the DIN track. The shape of the beam at each sensing distance can be adjusted by turning the beam shape control. 1 (E3C-LD11/-LR11) Turn the control to the left to adjust the focal position to short distance detection. Turn the control to the right to adjust the focal position to long distance detection. 2 DIN track Sensor head connector catches DIN track 2. Slide the Amplifier Units together, line up the clips, and press the Amplifier Units together until they click into place. 1 1 2 (E3C-LD21) Turn the control to the left to decrease the beam width. Turn the control to the right to increase the beam width. (E3C-LD31) Turn the control to the left to decrease the beam area. Turn the control to the right to increase the beam area. Do not turn the beam shape control to more than 60 mNm. Otherwise, this may damage the unit. Do not turn the beam shape control to more than 60 mN*m. This may damage the unit. (Separating Amplifier Units) Slide Amplifier Units away from each other, and remove from the DIN track one at a time. (Do not attempt to remove Amplifier Units from the DIN track without separating them first.) Note: 1. The specifications for ambient temperature will vary according to the number of Amplifier Units used together. For details, refer to Ratings and Specifications on page 5. 2. Always turn OFF the power supply before mounting or separating Amplifier Units. Mounting the End Plate (PFP-M) An End Plate should be used if there is a possibility of the Amplifier Unit moving, e.g., due to vibration. If a Mobile Console is going to be mounted, connect the End Plate in the direction shown in the following diagram. Optical axis alignment function The angle of beam projection can be adjusted by turning the optical axis alignment control. Turning the control about 45 to the right will move the optical axis to the left by the number of degrees shown below. Turning the control about 45 to the left will move the optical axis to the right by the number of degrees shown below. If the act of adjusting the optical axis changes the beam shape, adjust the beam shape again. Turning the control 180 will return the optical axis to its original position. Adjustment angle E3C-LR11 : Approx. 1.5 E3C-LR12 : Approx. 1.0 E3C-LD@@ : Approx. 2.0 EEPROM Writing Error End Plate If the data is not written to the EEPROM correctly due to a power failure or static-electric noise, initialize the settings with the keys on the Amplifier Unit. ERR/EEP will flash on the display when a writing error has occurred. Mounting the Mobile Console Head Optical Communications Leave a gap of at least 20 mm between the nearest Amplifier Unit and the Mobile Console head. Several Amplifier Units can be slid together and used in groups. Do not, however, slide the Amplifier Units or attempt to remove any of the Amplifier Units during operation. 20 mm Other Precautions Protective Cover Always keep the protective cover in place when using the Amplifier Unit. Mobile Console Adjustments Use the E3X-MC11-C1-SV2 Mobile Console for the E3C-LDA-series Amplifier Units. Mutual Interference Protection Function There may be some instability in the digital display values due to light from other sensors. If this occurs, decrease the sensitivity (i.e., decrease the power or increase the threshold) to perform stable detection. 11 E3C-LDA (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensor Heads E3C-LD11 12.7 18.5 6.6 2 LD ON indicator Operation indicator 13.2 12.8 2.7 dia. 2 AXIS control (Optical axis alignment control) 33 4.75 27.7 3.7 20 Two, 3.2-dia. mounting holes 5.1 6.6 FOCUS control (Beam shape control) R4.8 Emitter 3 dia. 3 25 18.8 6 Two, R 2.6 18 5 12.1 8.4 6 18 3 1.7 3.1 3.6 9.7 27 Receiver Connector 6 18 14.9 1.8-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.15 mm2), Standard length: 2 m E3C-LD21 E3C-LD31 With Beam Unit Attached 15.7 21.5 6.6 LD ON indicator 2 Operation indicator 13.2 12.8 5.3 2.7 dia.2 8 36 30.7 3.6 23 2 6 AXIS control (Optical axis alignment control) 5.1 Two, 3.2-dia. mounting holes 6.6 FOCUS control (Beam shape control) R4.8 Emitter 3 dia. 3.9 27 18.8 9 Two, R 2.6 19.5 7 2.1 4.1 Receiver 6 13.1 10.9 1 30 Connector 6 14.9 18 1.8-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.15 mm2), Standard length: 2 m 12 E3C-LDA E3C-LR11/-LR12 2 24.5 LD ON indicator 18.7 6.6 Operation indicator 13.2 12.8 2 2.7 dia. AXIS control (Optical axis alignment control) 39 33.8 2.2 8.8 3.1 7 5.1 26 6 4.4 (optical axis) Two, 3.2-dia. mounting holes R4.8 Emitter/ Receiver 3 dia. 9 25 20 20.9 6.6 FOCUS control (Beam shape control) *The E3C-LR12 does not have FOCUS control. 18.8 Two, R 2.6 12.1 6 3.1 2 33 6 14.9 Connector 18 1.8-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.15 mm2), Standard length: 2 m 13 E3C-LDA Amplifier Units Pre-wired Amplifier Units E3C-LDA11 E3C-LDA21 E3C-LDA41 E3C-LDA51 E3C-LDA11AT E3C-LDA41AT E3C-LDA11AN E3C-LDA41AN Main display Round ( ): Power tuning indicator Oblong ( ): 2nd operation indicator Operation indicator 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulation diameter: 1.1 mm), Standard length: 2 m Sub-display Connector 36.7 With Mounting Bracket Attached 3.9 x 3 =11.7 38.8 35.8 21.1 18.15 3.9 x 3 =11.7 2.5 * The Mounting Bracket can also be used on side A. (A)* 76 50.3 10 Connector 32 9.9 13.8 12.5 3.4 4.1 24.7 34.1 34.8 16 Two, 3.2-dia. mounting holes 3.4 Two, M3 Hole for optical communications Mounting Bracket (E39-L143) (Order separately) SUS304 stainless steel 4.4 16 Mounting Holes 34.1 16 14 E3C-LDA Amplifier Units with Wire-saving Connectors E3C-LDA6 E3C-LDA7 E3C-LDA8 E3C-LDA9 E3C-LDA6AT E3C-LDA8AT Main display Round ( ): Power tuning indicator Oblong ( ): 2nd operation indicator Sub-display Operation indicator Connector 36.7 With Mounting Bracket Attached 38.8 35.8 21.1 18.15 3.9 x 3 =11.7 3.9 x 3 =11.7 * The Mounting Bracket can also be used on side A. (A)* 82.7 79.2 2.5 76 10 50.3 Connector E3X-CN21 E3X-CN22 Connector 4 dia. 32 9.9 13.8 12.95 3.4 4.1 34.1 16 34.8 24.7 3.4 4.4 Hole for optical communications Mounting Bracket (E39-L143) (Order separately) SUS304 stainless steel Two, M3 16 34.1 16 Mounting Holes 15 E3C-LDA Amplifier Units with Wire-saving Connectors E3C-LDA6 E3C-LDA7 E3C-LDA8 E3C-LDA9 E3C-LDA6AT E3C-LDA8AT * Cable diameters are as follows: E3X-CN12 2.6 dia. E3X-CN22 4.0 dia. 82.7 79.2 Connector E3X-CN11 E3X-CN21 76 4 dia. 32 12.95 4 10 82.7 79.2 3 Connector E3X-CN12 E3X-CN22 76 A dia. * 32 17.45 12.95 11.55 4 3 4.8 Amplifier Unit with Connector for Sensor Communications Unit E3C-LDA0 38.8 10 11.7 35.8 21.1 18.15 11.7 95 2.5 13.8 10 76 19 50.3 32 32 9.9 13.8 3.4 4.1 34.1 24.7 16 34.8 4.4 28.1 Two, 3.2 dia. holes 3.4 16 Accessories (Order Separately) Reflectors Refer to E39-S/E39-R for details. Mounting Bracket Refer to E39-L for details. End Plate Refer to DIN rail for details. Wire-saving connector Refer to E3X-DA-S/MDA for details. Mobile Console Refer to E3X-DA-S/MDA for details. 16 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2014.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2014 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: E3C-LDA11AN E3C-LDA11AT E3C-LDA41AN E3C-LDA41AT E3C-LDA6AT E3C-LDA8AT E3C-LR11 4M E3XCN21 5M E3X-CN22 5M E3X-DA11RM-S E3X-DA11SE-S E3X-DA11TW-S E3X-DA41AN-S E3X-DA41RM-S E3XDA6AT-S E3X-DA6SE-S E3X-DA6TW-S E3X-DA8AT-S E3X-DA8RM-S E3X-DA8SE-S E3X-DAB41-S E3X-DAB6S E3X-DAB8-S E3X-DAG11-S E3X-DAG41-S E3X-DAG6-S E3X-DAG8-S E3X-DAH11-S E3X-DAH41-S E3XMC11-C1-S E3X-MDA6 E3X-DA11-S E3C-LDA51 2M E3C-LD21-2M E3C-LR11-2M E3C-LDA41-2M E3C-LR12-2M E3C-LD31-2M E3C-LDA21-2M E3X-DA41TW-S E3X-DAB11-S E3C-LDA11-2M