SPECIFICATION
MODEL
RATED CURRENT
RATED POWER
OUTPUT
CURRENT ADJ. RANGE
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.2
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS Note.3
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER TEMPERATURE
OVER VOLTAGE
Can be adjusted by internal potentiometer (A type only)
16ms at full load 230VAC / 115VAC
1000ms, 80ms / 115VAC at full load 500ms, 80ms / 230VAC at full load
90 ~ 305VAC 127VDC ~ 431VDC
47 ~ 63Hz
1.6A / 115VAC 0.8 A / 230VAC 0.7A / 277VAC
<0.75mA / 277VAC
-40 ~ +70 (Refer to "Derating Curve")℃
10 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
RIPPLE CURRENT
ENVIRONMENT
SAFETY &
EMC
PROTECTION
475 ~ 495V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
SHORT CIRCUIT
94%
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
HLG-120H-C350 HLG-120H-C500 HLG-120H-C700 HLG-120H-C1050 HLG-120H-C1400
±5%
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Derating may be needed under low input voltages. Please check the static characteristics for more details.
3. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1.
4. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
5. Refer to warranty statement.
6. Please refer to "DRIVING METHODS OF LED MODULE".
7. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547 light, industry level (surge L,N-FG: 4KV), criteria A
UL8750, CSA C22.2 No. 250.12-13, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP65 or IP67 approved
175 ~ 350mA 250 ~ 500mA
±1%
350 ~ 700mA
±1%
525 ~ 1050mA
±1%
700 ~ 1400mA
±1%
350mA
150.5W
215 ~ 430V 150V ~ 300V 107V ~ 215V 74V ~ 148V 54V ~ 108V
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
335 ~ 355V
94%
240 ~ 260V
94%
165 ~ 175V
94%
120 ~ 130V
93.5%
500mA 700mA 1050mA 1400mA
150W 150.5W 155.4W 151.2W
■ Features :
A : IP65 rated. Constant current level can be adjusted through internal potentiometer.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistance.
D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
Constant current design
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 94%
Protections: Short circuit / Over voltage / Over temperature
Cooling by free air convection
Output current adjustable through output cable or internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or 10V PWM signal or resistance)
Suitable for dry / damp / wet locations
5 years warranty (Note.5)
FMM
110
IP65 IP67
HLG-120H-C350 A
150W Single Output LED Power Supply HLG-120H-C series
File Name:HLG-120H-C-SPEC 2015-05-11
EMC IMMUNITY
EMC EMISSION
CURRENT ACCURACY ±5.0%
Compliance to EN55015, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3≧
CONSTANT CURRENT REGION
Note.6
RIPPLE & NOISE
2Vp-p 1.5Vp-p 1Vp-p 1Vp-p 1Vp-p
191.1K hrs min. MIL-HDBK-217F (25 )℃
220*68*38.8mm (L*W*H)
1.04Kg; 12pcs/13.5Kg/0.8CUFT
LINE REGULATION ±1%
COLD START 50A(t =600 s measured at 50% I ) at 230VAC
width peak
μ
Shut down o/p voltage, recovers automatically after temperature goes down
Constant current limiting, recovers automatically after fault condition is removed
TOTAL HARMONIC DISTORTION
THD< 20% when output loading 50% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC