Class 67 Ñ Miniature Plug-In
Time Delay Relay
11 pin octal base 12 amp multifunction time delay relay has 5 timing functions with timing ranges from 0.1 seconds to
9,999 hours. The input voltage range is 24-240 VAC or VDC. All functions and timing are selected from the thumb wheels
on the front panel. Red LED. Lamp indicator shows relay status. Repeatability when stabilized 0.1%. Contacts: Silver
cadmium oxide (gold flashed). Mates with socket 70-465-1. Size: 3.15 L ´1.76 W ´1.76 H.
Time Delay and Sensing Relays
Turn To Section 1 For Allied Office Addresses and Local Phone Numbers ALLIED
c
131
Class 211 Octal Ñ Time Delay Relays
CMOS circuitry controls operation and maintains timing accuracy to ±0.1% or 33 mS AC ±10 mS DC at constant voltage
and temperature. Rated 10 amps @ 120 VAC, 28 VDC. Temperature Range: Ð30¡C to +55¡C. Meets NEMA noise
immunity and 5000 volt test. Life: 500,000 operations at rated load.
*UL listed when used with 70-464-1 or 70-465-1 sockets, otherwise UL recognized.
AC Operation Ñ On Delay Function with 8 Pin Plug
Stock Mfr.Õs Timing Input
No. Type Range Voltage
EACH
10-241-9
850-4109 W211ACPSOX-5 0.1-10 sec. 120 VAC 47.24 39.02
850-4007 W211ACPSOX-7 1.0-180 sec. 120 VAC 68.08 56.23
850-4008 W211ACPSOX-8 2.0-300 sec. 120 VAC 47.24 39.02
850-4009 W211ACPSOX-18 0.1-1 sec. 120 VAC 47.24 39.02
850-4060 W211ACPSOX-60 1.0-15 min. 120 VAC 68.32 56.36
850-4010 W211ACPSOX-61 2.0-30 min. 120 VAC 47.36 39.07
850-4011 W211ACPSOX-62 4.0-60 min. 120 VAC 47.36 39.07
850-4012 W211ACPSOX-63 8.0-120 min. 120 VAC 47.36 39.07
DC Operation Ñ On Delay Function with 8 Pin Plug
850-4111 W211CPSOX-3 1.0-180 sec. 24 VDC 47.38 38.39
AC Operation Ñ Off Delay Function with 11 Pin Plug
850-4105 W211ACPSRX-5 0.1-10 sec 120 VAC 79.54 62.02
850-4107 W211ACPSRX-7 1.0-180 sec. 120 VAC 79.54 62.02
850-4108 W211ACPSRX-8 2.0-300 sec. 120 VAC 79.54 62.02
850-4013 W211ACPSRX-60 1.0-15 min. 120 VAC 52.11 40.63
DC Operation Ñ Off Delay Function with 11 Pin Plug
850-4014 W211CPSRX-1 0.1-10 sec. 24 VDC 51.05 38.39
850-4015 W211CPSRX-3 1.0-100 sec. 24 VDC 51.05 38.39
Class 388 Ñ Adjustable Time Delay Relays
Features long body with 0.1% repeatability. DPDT, 12 amp contacts. Field adjustable timing and on delay timing functions.
Mates with socket 70-463-1 and 16-1239 spring clip.
Stock Mfr.Õs Timing Input
No. Type Range Voltage
EACH
25-49 50-9910-241-9
850-5080 W388ACPSOX-42 0.1-10 sec. 120 VAC 65.18 58.85 54.33 50.44
850-5081 W388ACPSOX-44 1.0-180 sec. 120 VAC 65.18 58.85 54.33 50.44
Class 236 Ñ Adjustable Voltage Sensor
Class 236 sensing relays combine a solid state sensor with an SPDT, 13 amp or DPDT, 10 amp relay contact. Field adjustable
for pull-in and dropout. Can be used either as an over or under voltage detecting relay. Sensor is non-latching and has no
time delay. Pull-In: 75% to 115% of nominal. Dropout: 75% to 95% of pull-in. Mates with socket 70-463-1 or 70-464-1.
AC Operation
Stock Mfr.Õs Input
Fig.
No. Type Voltage
EACH
50-9925-4910-241-9
850-6101 W236ACX-1 A 120 VAC 61.50 58.85 54.33 50.44
850-6010 W236ACX-2 A 208, 220, 240 VAC 66.46 62.49 57.67 53.55
850-6102 W236ACX-4 A 480 VAC 72.58 67.06 61.91 57.48
850-6103 W236ACPX-1 B 120 VAC 84.53 76.26 70.40 65.37
850-6104 W236ACPX-4 B 24 VAC 76.62 70.19 64.79 60.17
DC Operation
850-6105 W236CPX-1 B 24 VDC 73.57 67.97 62.74 58.26
Class 222 Ñ Repeat Cycle Timer
Independently adjustable for both on and off timing. Octal style pin terminals and dual timing knobs. Rated 10 amps @
120 VAC/28 VDC. Mates with socket 70-464-1.
Stock Mfr.Õs Timing Input
No. Type Range Voltage
EACH
10-24 25-491-9
850-4128 W222ACPFX-16 3-300 sec. 120 VAC 56.50 52.13 48.41
On delay relays are slow operating. DPDT contacts are rated at 5 amps @ 120 VAC, 28 VDC resistive. Temperature Range:
Ð10¡C to +55¡C. Timing adjustment by screw. Plug-in style uses class 67, 6 pole socket. Mates with sockets 70-307 and 70-308.
Stock Mfr.Õs Timing Input
No. Type Range Voltage
EACH
10-24 25-49 50-991-9
850-1031 W67CPSOX-1 0.1-30 sec. 12 VDC 50.24 45.13 41.66 38.69
850-1032 W67CPSOX-2 0.1-30 sec. 24 VDC 50.24 45.13 41.66 38.69
Class 235 Ñ Current Sensing Relay
Class 235 relays are field adjustable for detecting AC current levels. The sensor is non-latching and has no time delay.
Contacts rated at 10 amps @ 120 VAC, 6 A, 28 VDC. Current Detecting Range: 1.5 A to 15 amps. Temperature Range:
Ð10¡C to +55¡C. Note:
3
/
16
" terminal is socket compatible with 388 style sockets.
1
/
4
" terminal is solder/QC and not socket
compatible,
1
/
4
" style uses taped hole and antirotation tab for panel mount. Mates with socket 70-463-1 and 16-1239
spring clip.
Stock Mfr.Õs Input
Terminals
No. Type Voltage
EACH
10-24 25-491-9
850-6009 W235ACX-2
1
/
4
" 120 VAC 58.41 53.82 49.69
850-6106 W235ACX-3
3
/
16
" 120 VAC 61.23 55.76 51.48
*
4
Magnecraft &
Struthers-Dunn
*
UL Recognized
File No. E43641
TDR-PRO-5000 Programmable Time Delay Relay
Stock Mfr.Õs Timing Input
No. Type Range Voltage
EACH
25-49 50-9910-241-9
850-0390 TDR-PRO-5000 0.1 sec.-9999 hr. 24-240 VAC/VDC 77.35 70.91 65.45 60.78
Pending Pending
UL Recognized
File No. E43641
UL Recognized
File No. E62636
UL Recognized
File No. E43641
UL Recognized
File No. E43641
UL Recognized
File No. E62636
Ñ NEW Ñ