D1201UK
Document Number 3203
Issue 3
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Parameter Test Conditions Min. Typ. Max. Unit
VGS = 0 ID= 100mA
VDS = 12.5V VGS = 0
VGS = 20V VDS = 0
ID= 10mA VDS = VGS
VDS = 10V ID= 1A
PO= 10W
VDS = 12.5V IDQ = 0.2A
f = 500MHz
VDS = 0 VGS = –5V f = 1MHz
VDS = 12.5V VGS = 0 f = 1MHz
VDS = 12.5V VGS = 0 f = 1MHz
V
mA
μA
V
S
dB
%
—
pF
pF
pF
ELECTRICAL CHARACTERISTICS (Tcase = 25°C unless otherwise stated)
Drain–Source
BVDSS Breakdown Voltage
Zero Gate Voltage
IDSS Drain Current
IGSS Gate Leakage Current
VGS(th) Gate Threshold Voltage*
gfs Forward Transconductance*
GPS Common Source Power Gain
ηDrain Efficiency
VSWR Load Mismatch Tolerance
Ciss Input Capacitance
Coss Output Capacitance
Crss Reverse Transfer Capacitance
40
1
1
17
0.8
10
50
20:1 60
40
4
HAZARDOUS MATERIAL WARNING
The ceramic portion of the device between leads and metal flange is beryllium oxide. Beryllium oxide dust is highly
toxic and care must be taken during handling and mounting to avoid damage to this area.
THESE DEVICES MUST NEVER BE THROWN AWAY WITH GENERAL INDUSTRIAL OR DOMESTIC WASTE.
RTHj–case Thermal Resistance Junction – Case Max. 3.5°C / W
THERMAL DATA
* Pulse Test: Pulse Duration = 300 μs , Duty Cycle ≤2%