MtronPTI reserves the right to make changes to the product(s) and service(s) described herein without notice. No liability is assumed as a result of their use or application.
PARAMETER Symbol Min. Typ. Max. Units Condition/Notes
Frequency Range F 50 1400 MHz See Note 1
Operating Temperature T
A
(See ordering information)
Storage Temperature T
S
-55 +125 °C
Frequency Stability ∆F/F (See ordering information) See Note 2
Aging
1st Year -3 +3 ppm
Thereafter (per year) -1 +1 ppm
Supply Voltage Vcc 1.71 1.8 1.89 V LVDS/CML
2.375 2.5 2.625 V
3.135 3.3 3.465 V
Input Current Icc 125 mA LVPECL/LVDS/CML
Load See Note 3
50 Ohms to (Vcc -2) Vdc LVPECL Waveform
100 Ohm differential load LVDS/CML Waveform
Symmetry (Duty Cycle) 45 55 % LVPECL – Vdd-1.3 V
LVDS – 1.25 V
Output Skew 20 ps LVPECL
15 ps CML
20 ps LVDS
Differential Voltage Vod 250 350 450 mV LVDS
Vod 0.7 .095 1.20 Vpp CML
Common Mode
Output Voltage Vcm 1.2 V LVDS
Logic “1” Level Voh Vcc -1.02 V LVPECL
Logic “0” Level Vol Vcc -1.63 V LVPECL
Rise/Fall Time Tr/Tf 0.23 0.50 ns @ 20/80% LVPECL, LVDS, CML
Enable Function 80% Vcc min or N/C: Output active Output Option B or G
0.5V max: Output disables to high-Z
0.5V max or N/C: Output active Output Option S or M
80% Vcc min: Output disables to high-Z
Start up Time 10 ms
Phase Jitter
@ 622.08 MHz φJ 0.25 ps RMS Integrated 12 kHz – 20 MHz
Phase Noise @ 622.08 MHz
10 Hz -60 dBc/Hz
100 Hz -97 dBc/Hz
1 KHz -107 dBc/Hz
10 KHz -116 dBc/Hz
100 KHz -121 dBc/Hz
1 MHz -134 dBc/Hz
10 MHz -146 dBc/Hz
Electrical Specifications
100 MHz -148 dBc/Hz
Mechanical Shock Per MIL-STD-202, Method 213, Condition C (100 g’s, 6 mS duration, ½ sinewave)
Vibration Per MIL-STD-202, Method 201 & 204 (10 g’s from 10-2000 Hz)
Hermeticity Per MIL-STD-202, Method 112, (1x10
-8
atm. cc/s of Helium)
Thermal Cycle Per MIL-STD-883, Method 1010, Condition B (-55°C to +125°C, 15 min. dwell, 10 cycles)
Solderability Per EIAJ-STD-002
Environmental
Max Soldering Conditions See solder profile, Figure 1
Note 1: Contact factory for standard frequency availability over 945 MHz
Note 2: Stability is inclusive of initial tolerance, deviation over temperature, shock, vibration, supply voltage, and aging for one
year at 50°C mean ambient temperature.
Note 3: See Load Circuit Diagram in this Datasheet. Consult factory with nonstandard output load requirements.