Datasheet
Wing Union/Hammer Union
Pressure Sensors
Models 435/437
0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to 10000 psi;
0 psi to 15000 psi; 0 psi to 20000 psi; 0 bar to 350 bar;
0 bar to 400 bar; 0 bar to 700 bar; 0 bar to 1000 bar; 0 bar to 1350 bar
2sensing.honeywell.com
Wing Union/Hammer Union Pressure Sensors
Models 435/437
Honeywell’s Models 435/437 Wing Union/Hammer Union Pressure Sensors are rugged devices designed for use with
Weco® 1502 fittings for both offshore and land-based oil and gas applications.
Available in two accuracy levels (±0.1 %FSS BFSL or ±0.2 %FSS BFSL), Models 435/437 are typically used in demanding
applications such as well stimulation and circulation systems. The higher accuracy option (available on Model 435 only)
at ±0.1 % full scale provides more confidence in the actual measured pressure value, particularly for smaller changes in
pressure, allowing drilling operation adjustments as needed.
Models 435/437 are constructed as an all-welded, stainless steel assembly with the sensor diaphragm and wing union
fitting machined as one part. This helps provide hermetic integrity, which reduces the chance of media leakage vs. multi-
piece parts, and increases reliability. The isolated pressure sensing diaphragm minimizes zero-shift during hammer up
and eliminates long-term signal drift in the field. The Weco® 1502 (50,8 mm [2 in]) Wing Union-compatible fittings are
machined of Inconel® X-750, which provides additional durability with highly abrasive and corrosive media, while the
Honeywell proprietary stainless steel electrical connection provides enhanced secondary pressure containment.
Each sensor undergoes special assembly processes to survive high shock and vibration for more reliable performance in
the field.
ACCURATE • DURABLE • CONFIGURABLE
Potential Applications
• Acidizing
Choke manifold
Fracturing and cementing
Mud pumps / mud logging
New well development and extraction
Oil and gas drilling
Service and cement trucks
• Standpipe
• Stimulation
Well head measurement
Features
High accuracy ±0.1 %FSS BFSL (Model 435); standard
accuracy ±0.2 %FSS BFSL (Models 435/437) (see Table 1)
All-welded one-piece, hermetically sealed, stainless-steel
construction
Standard aperture (Model 435) and wide aperture (Model 437)
pressure ports available to support media blends with high
viscosities
• Inconel® X-750 wetted parts provide additional durability with
abrasive or corrosive media
Multiple electrical connectors supported
High accuracy shunt calibration option allows users the ability
to validate the offset signal in the eld, ensuring the sensor
is actively plugged into the system; one-wire and two-wire
options available (see Table 3 for additional information)
Protective cage option provides extra electrical connection
protection and increases durability
RFI/EMI protected
Intrinsically safe: CFMUS/ATEX/IEC Ex certication
CE approved
Model 435
with protective cage
Model 435 Model 437
with protective cage
Model 437
3
sensing.honeywell.com
Wing Union/Hammer Union Pressure Sensors
Table 1. Performance Specifications
Characteristic Measure
Pressure ranges 0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to 10000 psi; 0 psi to 15000 psi; 0 psi to 20000 psi2;
0 bar to 350 bar; 0 bar to 400 bar; 0 bar to 700 bar; 0 bar to 1000 bar; 0 bar to 1350 bar2
Accuracy1High accuracy: ±0.1 %FSS (Model 435)
Standard accuracy: ±0.2 %FSS (Model 435/Model 437)
Calibration Standard 5-point calibration: 0 %, 50 %, and 100 % of full scale
Special 10 point and 20 point calibration options available
Output 4 mA to 20 mA, two-wire
Resolution Innite
1Accuracies stated are with respect to best t straight line (BFSL) for all errors including linearity, hysteresis, and non-repeatability through zero.
2 Working pressure and approval limited to 15000 psi [1000 bar]. Amplier enhancement options 3H and 3HJ will allow overpressure reading to 20000 psi
[1350 bar].
Table 2. Environmental Specifications
Characteristic Measure
Temperature, operating -40 °C to 125 °C [-40 °F to 257 °F]
Temperature, compensating -40 °C to 85 °C [-40 °F to 185 °F]
Temperature effect, zero <±0.018 %FSS/°C [0.01 %FSS/°F]
Temperature effect, span <±0.018 % reading/°C [0.01 % reading/°F]
Temperature effect, sealing IP68 / NEMA 6P
Table 3. Mechanical Specifications
Characteristic Measure
Media Corrosive and abrasive service, Inconel® X-750
Overload, safe 150 % rated full scale pressure or limit of Weco® 1502 tting
Overload, burst 250 % rated full scale pressure or limit of Weco® 1502 tting
Pressure port Weco® 1502 wing union, 51 mm [2 in] pipe, male sub end
Wetted parts material Inconel® X-750
Weight (approx.) 4.85 lb [2.2 kg]
Housing material 316L stainless steel (with laser engraved labels)
Protective cage (optional) 316L stainless steel
4sensing.honeywell.com
Model 435/437
Table 4. Electrical Specifications
Characteristic Measure
Supply voltage 9 Vdc to 28 Vdc
Output signal 4 mA to 20 mA
Output at null pressure 4 mA ±0.2 %FSS
Full Scale Span (FSS) 16 mA ±0.5 %FSS
Insulation resistance >100 MOhm at 20 Vdc
Max. loop resistance 950 ohm @ 28 V decreasing linearly to 0 ohm @ 9 V
Circuit protection Reverse polarity protection of supply leads
RFI/EMI protection Noise immunity up to 2.7 GHz
Frequency response 2500 Hz
Zero and span adjustment Digital adjustment at non-hazardous locations using factory supplied communication kit.
Consult factory for more information.
Electrical termination
MS series compatible 4-pin (32A-14S-2P-10-M2);
Bendix PT, 6-pin (PTIH-10-6P);
Jupiter M-series 4-pin;
Jupiter M-series 7-pin;
Rota B-Series 4-pin
Shunt calibration wiring options None / One-wire / Two-wire
Shunt calibration signal range 100 %FSS
Shunt calibration accuracy <±0.2 %FSS
NOTE: High Accuracy Shunt Calibration - Shunt calibration option provides a pre-determined change in electrical output as per shunt calibra-
tion signal range without the need for a calibrated pressure source. Example: If sensor output = 4 mA, FSS = 16 mA and shunt calibration signal
range = 100 %FSS (i.e. 16 mA), then sensor output while shunt calibration is engaged = 4 mA + 16 mA = 20 mA.
Shunt Calibration Activation/Engaging Mechanisms - Models 435/437 Wing Union Pressure Sensors support either one of the following two
types of shunt calibration activation/engaging mechanisms:
1-wire shunt calibration: Shunt calibration is engaged while the electrical terminal “Shunt Cal” provided on the sensor is shorted with the “Re-
turn” terminal. Sensor output returns to previous value as soon as the short is removed.
2-wire shunt calibration: Shunt calibration is engaged while a potential in the range of 9 Vdc to 28 Vdc is applied between two electrical termi-
nals “+ Shunt Cal” and “- Shunt Cal” provided on the sensor. Sensor output returns to previous value as soon as the potential is removed.
Refer to installation instruction manual 008-0691-00 for wiring diagrams.
Table 5. Intrinsically Safe Approvals
(See Honeywell’s Web site (http://measurementsensors.honeywell.com) for up-to-date information regarding intrinsically safe approvals,
ref. #008-0691-00.)
Agency Approvals
cFMus
Class 1, Div 1, Groups A, B, C, D
Class 1, Zone 0, AEx / Ex ia IIC T4/T5 Ga (T4 at Ta≤85˚C, T5 at Ta≤40˚C);
Install per 008-0691-00
ATEX II 1 G Ex ia IIC T4/T5 Ga (T4 at Ta≤85˚C, T5 at Ta≤40˚C)
IEC Ex Ex ia IIC T4/T5 Ga (T4 at Ta≤85˚C, T5 at Ta≤40˚C)
5
sensing.honeywell.com
Wing Union/Hammer Union Pressure Sensors
Figure 1. Model 435
Figure 2. Model 437
Electrical Connector:
(comes with cap protection)
Bendix PT 6-Pin (PTIH-10-6P)
or MS Series Compatible 4-Pin
(32A-14S-2P-10-M2)
Electrical Connector:
(comes with cap protection)
Jupiter M Series 7-Pin
(REC-M-10TPN-07-20)
or Jupiter M Series 4-Pin
(REC-M-10TPN-04-16)
or ROTA B Series 4-Pin
Electrical Connector:
(comes with cap protection)
Bendix PT 6-Pin (PTIH-10-6P)
or MS Series Compatible 4-Pin
(32A-14S-2P-10-M2)
Protective cage and
cap not shown
for clarity
See detail See detail
See detail
Protective
cage
Part label and
product certicate
labels
Part label and
product certicate
labels
Part label and
product certicate
labels
Protective
cap
Protective
cap
Protective
cap
Black exible
carrying handle
(WECO Wing Union
nut ts over handle)
Black exible
carrying handle
(WECO Wing Union
nut ts over handle)
91,44 mm
[3.6 in]
Ø 93,98 mm
[Ø 3.7 in]
Ø 93,98 mm
[Ø 3.7 in]
111,76 mm
[4.4 in]
Ø 93,98 mm
[Ø 3.7 in]
203,2 mm
[8 in]
68,58 mm
[2.7 in]
Detail scale 2:1
Ø 19,05 mm
[Ø 0.75 in]
Ø 11,18 mm
[Ø 0.44 in]
22,35 mm
[0.88 in]
78,74 mm
[3.1 in]
Protective
cap
See detail
Part label and
product certicate
labels
Black exible
carrying handle
(WECO Wing Union
nut ts over handle)
Protective
cap
Protective
cap
Black exible
carrying handle
(WECO Wing Union
nut ts over handle)
Part label and
product certicate
labels
See detail
Part label and
product certicate
labels
See detail
Protective
cage
Electrical Connector:
(comes with cap protection)
Bendix PT 6-Pin (PTIH-10-6P)
or MS Series Compatible 4-Pin
(32A-14S-2P-10-M2)
Electrical Connector:
(comes with cap protection)
Jupiter M Series 7-Pin
(REC-M-10TPN-07-20)
or Jupiter M Series 4-Pin
(REC-M-10TPN-04-16)
or ROTA B Series 4-Pin
Electrical Connector:
(comes with cap protection)
Bendix PT 6-Pin (PTIH-10-6P)
or MS Series Compatible 4-Pin
(32A-14S-2P-10-M2)
Protective cage and
cap not shown
for clarity
88,9 mm
[3.5 in]
Ø 93,98 mm
[Ø 3.7 in]
22,35 mm
[0.88 in]
9,65 mm
[0.38 in]
Detail scale 2:1
Ø 93,98 mm
[Ø 3.7 in]
Ø 93,98 mm
[Ø 3.7 in]
111,76 mm
[4.4 in]
203,2 mm
[8 in]
68,58 mm
[2.7 in]
78,74 mm
[3.1 in]
DIMENSIONS (for reference only)
6sensing.honeywell.com
Model 435/437
NOMENCLATURE
BP435
Pressure
Type
EJ
Pressure Range
(Gauge)
6
Accuracy
5±0.1 % FSS2
1AC
Temperature
Compensation
1AC -40 °C to 85 °C
[-40 °F to 185 °F]
2AK
Internal
Amplifiers
Amplifier
Enhancements3
BP435
6Z
Electrical
Termination
Calibration
Options
6A
6BF
6Z
Jupiter M Series
4-pin
6BG Jupiter M Series,
7-pin
10E
Material
Type
Inconel®
X-750 wetted
diaphragm
10E
9A Special cal.,
10 point
9B Special cal.,
20 point
5-point
calibration
6BH Rota B-Series,
4-pin
7AD
Wiring
Options4
None
3J
3D One-wire
shunt calibration
3HJ
3H 4 mA to 16 mA for
0 to 15000 psi (EL) or
0 to 1012 bar (NU)
with over-range up to
20 mA, no shunt
calibration
4 mA to 16 mA for
0 to 15000 psi (EL) or
0 to 1012 bar (NU)
with over-range up to
20 mA, two-wire
shunt calibration
7AD 4-Pin Standard
A: N/C or Shunt Cal.; B: + Output
C: + Supply; D: Case Ground
7AF
7AE
7AG
4-Pin Jupiter
1: N/C or Shunt Cal.
2: Case Ground; 3: + Output
4: + Supply
6-Pin Standard
A: + Supply; B: + Output
C: N/C; D: Case Ground
E: N/C; F: N/C or Shunt Cal.
7-Pin Jupiter
1: N/C; 2: Case Ground; 3: N/C
4: + Supply; 5: + Output
6: N/C; 7: N/C or Shunt Cal.
7AH
6-Pin w/2-wire shunt
A: + Supply; B: + Output; C: N/C
D: Case Ground; E: + Shunt Cal.
F: - Shunt Cal.
DR 5000 psi
DV
DS 6000 psi
10000 psi
EJ 15000 psi
NN
NG 350 bar
400 bar
NH 700 bar
MN 1000 bar
EL 20000 psi1
NU 1350 bar1
Notes:
1 Working pressure and approval limited to 15000 psi. Amplifier will allow overpressure readings to 20000 psi.
2 ±0.1 % FSS accuracy available on Model 435 only.
3 3D and 3J are available with all pressure ranges except EL and NU. 3H and 3HJ are available only with pressure ranges EL and NU.
4 Wiring option availability varies with electrical termination.
Option 7AD available only with Option 6Z
Option 7AE available only with Option 6BF
Option 7AF and 7AH available only with Option 6A
Option 7AG and 7AP available only with Option 6BG
Option 7AN available only with Option 6BH
Other wiring options available upon request.
5 Protective cage available only with electrical terminations 6A and 6Z.
6±0.2 % FSS
2AK 4 mA to 20 mA,
two wire,
intrinsically safe
Two-wire
shunt calibration
Bendix PT, 6 -pin,
PTIH-10-6P
MS Series
compatible 4-pin,
32A-14S-2P-10-M2
7AN
4-Pin Rota
B: N/C or Shunt Cal.
C: Case Ground; E: + Output
F: + Supply
7AP
7-Pin Jupiter w/2-wire shunt
1: N/C; 2: Case Ground; 3: N/C
4: + Supply; 5: + Output
6: + Shunt Cal.; G: - Shunt Cal
Protective
Cage
45E Protective
cage5
None
BP437
3D
Table 6. Order Guide (Sample Listings)
Order Code Description
BP435EJ,6,1AC,2AK,3D,6Z, 7AD,10E
Model 435, 15000 psi, ±0.2 %FSS accuracy, -40 °C to 85 °C [-40 °F to 185 °F] temperature
compensation, 4 mA to 20 mA two-wire intrinsically safe, one-wire shunt calibration, MS compatible,
4-pin connector, Inconel® X-750 wetted diaphragm
BP435DS,5,1AC,2AK, 3J, 6A, 7AH,10E
Model 435, 6000 psi, ±0.1 %FSS accuracy, -40 °C to 85 °C [-40 °F to 185 °F] temperature
compensation, 4 mA to 20 mA two-wire intrinsically safe, two-wire shunt calibration, Bendix PT 6-pin
connector, Inconel® X-750 wetted diaphragm
BP435NU,6,1AC,2AK,3H,6Z, 7AD,10E, 45E
Model 435, 1350 bar, ±0.2 %FSS accuracy, -40 °C to 85 °C [-40 °F to 185 °F] temperature
compensation, intrinsically safe, 4 mA to 16 mA at 1012 bar with over-range up to 20 mA at 1350
bar, no shunt calibration, MS compatible 4-pin connector, Inconel® X-750 wetted diaphragm, with
protective cage
BP437DR,6,1AC,2AK,6BF, 7AE,10E
Model 437, 5000 psi, ±0.2 %FSS accuracy, -40 °C to 85 °C [-40 °F to 185 °F] temperature
compensation, 4 mA to 20 mA two-wire intrinsically safe, no shunt calibration, Jupiter M series 4-pin
connector, Inconel® X-750 wetted diaphragm
32301963-1-EN IL50 GLO
November 2014
Copyright © 2014 Honeywell International Inc. All rights reserved.
® Inconel is a registered trademark of Inco Alloys International, Inc.
® Weco is registered trademark of Fmc Corporation
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For application
assistance, current specifications,
pricing or name of the nearest
Authorized Distributor, contact
your local sales office.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
http://measurementsensors.
honeywell.com, or e-mail inqui-
ries to info.tm@honeywell.com
ADDITIONAL INFORMATION
The following associated literature is available on the Sensing and
Control web site at measurementsensors.honeywell.com:
Product installation instructions
Product range guide
Product application-specific information
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.