MCC S85A omponents 21201 Itasca Street Chatsworth !"# $ % !"# THRU S85M Features * * * * 85 Amp Rectifier 50 to 1000 Volts High Surge Capability Low Leakage Low Forward Voltage Drop High Current Capability Maximum Ratings * * DO-5 Operating Temperature: -65C to +175C Storage Temperature: -65C to +175C B MCC Part Number S85A S85B S85D S85G S85J S85K S85M Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum RMS Voltage Maximum DC Blocking Voltage 35V 70V 40V 280V 420V 560V 700V 50V 100V 200V 400V 600V 800V 1000V N M C J K D P G H F E Electrical Characteristics @ 25C Unless Otherwise Specified Average Forward IF(AV) 85 A TL = 140C Current Peak Forward Surge IFSM 1450A 8.3ms, half sine Current IFM = 85.0A; Maximum 1.20V Instantaneous VF TA = 25C Forward Voltage Maximum DC Reverse Current At IR 25A TA = 25C Rated DC Blocking 150A TA = 55C Voltage Typical Junction CJ 240pF Measured at Capacitance 1.0MHz, VR=4.0V *Pulse Test: Pulse Width 300sec, Duty Cycle 1% A DIMENSIONS DIM A B C D E F G H J K M N P INCH ES MIN 1/4-28 .669 --------.422 .115 ----.220 ----.156 --------.140 www.mccsemi.com MAX Threads .687 .794 1.000 .453 .200 .450 .249 .375 ----.667 .080 .175 MM MIN Standard 17.19 --------10.72 2.93 ----5.58 ----3.96 --------3.56 MAX Polarity 17.44 20.16 25.40 11.50 5.08 11.43 6.32 9.52 ----16.94 2.03 4.45 NOTE MCC S85A thru S85M Figure 1 Typical Forward Characteristics 200 Figure 2 Forward Derating Curve 100 100 60 40 90 20 25C 80 Amps 10 6 60 Amps 4 40 2 20 1 .6 0 .4 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 50 75 100 125 150 175 C .2 .1 0.8 0.6 1.0 1.2 1.4 Average Forward Rectified Current - Amperes versus Ambient Temperature - C 1.6 Volts Instantaneous Forward Current - Amperes versus Instantaneous Forward Voltage - Volts Figure 3 Junction Capacitance 1000 600 400 200 pF TJ=25C 100 60 40 20 10 .1 .2 .4 1 Volts 2 4 10 20 40 100 200 400 Junction Capacitance - pF versus Reverse Voltage - Volts www.mccsemi.com 1000 MCC S85A thru S85M Figure 4 Typical Reverse Characteristics Figure 5 Peak Forward Surge Current 2000 1000 600 400 1500 200 1000 100 600 60 Amps 40 400 200 20 0 TA=125C Amps 10 1 2 4 6 40 60 80 100 Cycles 6 Peak Forward Surge Current - Amperes versus Number Of Cycles At 60Hz - Cycles 4 2 1 .6 .4 TA=25C .2 .1 8 10 20 20 40 60 80 100 120 140 Volts Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts www.mccsemi.com