1
Power entry modules with line filter 5145
www.schurter.com/pg06
Connectors
Inlet filter, front side mounting, circuit breaker TA45 2-pole
Standard- or Medical-Filter
C14
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in
standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter 6145
- We recommend for new applications type DF12
Approvals
- VDE License Number: 117118
- UL License Number: E72928
Characteristics
- All single elements are already wired
Unwired versions available on request
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage release or remote trip release
- Qualified for use in equipment according IEC/EN 60950
References
General Product Information
Weblinks
Approvals: www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
CHINA-RoHS: www.schurter.com/china-rohs
Webstore: www.schurterinc.com/estore/search.ihtml
Technical Data
Ratings IEC 1 - 10 A @ Ta 40 °C / 250 VAC; Hz 50
Ratings UL/CSA 1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
Leakage Current standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
Dielectric Strength > 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
Allowable Operation Temp. -10 °C to 55 °C
Climatic Category 10/055/21 acc. to IEC 60068-1
Degree of Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I acc. to IEC 61140
Terminal Quick connect terminals 6.3 x 0.8 mm
Panel Thickness s Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Material: Housing Thermoplastic, black, UL 94V-0
Appliance-Inlet /-Outlet C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
condition) pin-temperature 70 °C, 10 A,
Protection class I
Circuit breaker Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In 3A/240VAC : 300A
Line Switch Rocker switch 2-pole non-illuminated or
illuminated acc. to IEC 61058-1
Technical details
Line Filter Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
MTBF > 100'000 h acc. to MIL-HB-217 F
2
Power entry modules with line filter
5145
www.schurter.com/pg06
Connectors
Dimensions Length 67.5 mm
3.25
+0.1
0
±0.1
43
M3/ø 3.6
2
1
ø 6
Detail A
50.7
67.5* 13.5
6.3x0.8mm
6.3x0.8mm
36
80
91.5
72
80
R 3
29
0
-0.5
0
+0.2
A
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type Inductances
L [mH]
Capa-
citance CX
Capa-
citance CY
R [MW]
1 Standard Version 2 x 11 47 2.2 -
2 Standard Version 2 x 4 47 2.2 -
3 Standard Version 2 x 2.5 47 2.2 -
4 Standard Version 2 x 1.6 47 2.2 -
6 Standard Version 2 x 0.7 47 2.2 -
8 Standard Version 2 x 0.6 47 2.2 -
10 Standard Version 2 x 0.4 47 2.2 -
15 Standard Version 2 x 0.1 47 2.2 -
1 Medical Version (M5) 2 x 11 47 - 1
2 Medical Version (M5) 2 x 4 47 - 1
6 Medical Version (M5) 2 x 0.7 47 - 1
8 Medical Version (M5) 2 x 0.6 47 - 1
10 Medical Version (M5) 2 x 0.4 47 - 1
15 Medical Version (M5) 2 x 0.1 47 - 1
Diagrams
Standard version
1) Line
2) Load
Medical version
1) Line
2) Load
3
Power entry modules with line filter 5145
www.schurter.com/pg06
Connectors
Attenuation Loss - - - - differential mode _____ common mode
Standard version
1 A 2 A 3 A 4 A
6 A 8 A 10 A 15A
Medical version (M5)
1 A 2 A 3 A 4 A
6 A 8 A 10 A 15A
Packaging unit 20 Pcs
Accessory
Description
Assorted Covers
Rear Cover
4
Power entry modules with line filter
5145
www.schurter.com/pg06
Connectors
/ 7 £xä ä
ÕÀÃ
-ÜÌV vÀÌ ,ViÀ
7L>V ÜÌi q
L>V L>V q
ÈL>V q À>}i ÌÀ>ë°
iLÃÃi` É ,iiv
«ÀÌi` É Li`ÀÕVÌ ÜÌi É ÜiÃÃ
«ÀÌi` É Li`ÀÕVÌ L>V É ÃVÜ>Àâ
«ÀÌi` É Li`ÀÕVÌ ÜÌi É ÜiÃÃ
-ÕÀv>Vi ÕÃÌÀ>Ì ÕÀ v «ÀÌ
,ViÀ i}i`
"
"
"
"
"
"
«ÀÌi` L>V
*«ÀÌi` ÜÌi
,«ÀÌi` L>V
-ÕÀv>Vi ÕÃÌÀ>Ì ÕÀ v «ÀÌ
U 7ÌÕÌ ÌiÀ> ÛiÀ>` «ÀÌiVÌ\ V`i ää
U 7Ì ÌiÀ> ÛiÀ>` «ÀÌiVÌ\ À>Ìi` VÕÀÀiÌ ®
,>Ìi` VÕÀÀiÌ\
7ÌÕÌ Àii>Ãi\ V`i ä
1`iÀÛÌ>}i Àii>Ãi ,iÌi ÌÀ« Àii>Ãi
1
L
1
L>
1
V
1 < `i
,>Ìi`
ÛÌ>}i 1
U U U
UUU
UUU
U
U
U
Ó
Î
{
Ó{ä 6 
ÓÎä 6 
£Óä 6 
Pr Óä
"
"
"
*ÃÌ v Ìi ÀViÀ i}i`
i°}
`i
ä]£ ä£
ä]Ó äÓ
ä]Î äÎ
ä]{ ä{
ä]x äx
ä]È äÈ
ä]Ç äÇ
ä]n än
ä] ä
£]ä £ä
£]£ ££
£]Ó £Ó
`i
£]Î £Î
£]{ £{
£]x £x
£]È £È
£]Ç £Ç
£]n £n
£] £
Ó]ä Óä
Ó]£ Ó£
Ó]Ó ÓÓ
Ó]Î ÓÎ
Ó]x Óx
`i
Ó]n Ón
Î]ä äÎä
Î]x äÎx
{]ä ä{ä
{]x ä{x
x]ä äxä
È]ä äÈä
È]x äÈx
Ç]ä äÇä
Ç]x äÇx
n]ä änä
]ä ää
`i
£ä]ä £ää
££]ä ££ä
£Ó]ä £Óä
£Î]ä £Îä
£{]ä £{ä
£x]ä £xä
/>Li £ -iiVÌ vÀ ÌÞ«i /{x
"À`iÀ iÝ>«i
U i ÃÜÌV
U Ó«i] ÀViÀ >VÌÕ>Ìi`
U +ÕV ViVÌ ÌiÀ>
"ÌiÀ ÌÞ«ià  ÀiµÕiÃÌ
7ÌÕÌ Õ>Ì
7Ì Õ>Ì ÓÓäoÓ{ä 6
££äo£Óä 6
Îx
>
>}À>
/iÀ> ÛiÀ>` «ÀÌiVÌ ÜÌÕÌ ÜÌ £«i ÜÌ Ó«i
 / 
äÓ £Ó ÎÓ
ä{ £{ Î{
È
Î{ Î
Èx
P
5
Power entry modules with line filter 5145
www.schurter.com/pg06
Connectors
10’000
60
2’000
1’000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
[ x In]
10854321,32
Type TA45
Rated current I 3... 15 A
1-pole protected
2-pole protected
Ambient temp. +23 °C
Multiple of rated current
Tripping time
n
10’000
60
2000
1000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
Multiple of rated current
[ x In]
10854321,32
Tripping time
Type TA45
Rated current In < 3 A
1-pole protected
2-pole protected
Ambient temp. +23 °C
Technical data (continued)
Circuit breaker
Tripping characteristics
In< 3 A
Tripping characteristics
In*3…)15 A
Effect of ambient temperature 1)
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for a lower or higher ambient tempera-
ture, use a correction factor from the table below.
*Ambient temperature [°C] Correction factor
–10 0,89
5 0,91
0 0,92
+23 1,00
+30 1,03
+40 1,08
+55 1,16
Order code TA45
(2-pole rocker-switch without
accessories)
ABTWF150C0 .001
see table 1
Order code (Order example)
Wiring
0Without
1With
Type of line filter
1Standard
3Medical
Rated current of line filter
11 (A) 56 (A)
22 (A) 68 (A)
33 (A) 710 (A)
44 (A) 815 (A)
Please note that Schurter will establish an internal part number for logistical use in additional to the order code. The format of this internal part
number is, for example 5145.0031.001
1) Example
Rated current at +23 °C 6,0 A
Ambient temperature +40 °C
Correction factor 1,08
Chosen rated current at
+ 40 °C ambient temperature 6 A x 1,08 = 6,5 A
* Temperature must be measured at the rear of the breaker next to
the terminals after equipment operating temperature has been
reached.
Type
5145.
The specifications, descriptions and illustrations indicated in this document are based on
current information. All content is subject to modifications anamendments.