DC-EC Series – General purpose DC LV DT
DC-EC Series Rev. 7 www.meas-spec.com 2015-July
1/4
• High level ±10VDC output
• Stroke ranges from ±0.05 to ±10in
• 0.25% linearit y
• Reverse polarity protection
• Double ma g n etic shielding
• Stainless steel housing
• Imperial or metric threaded core
DESCRIPTION
The DC-EC Series DC operated LVDTs combine a computer-designed AC LVDT with custom integral signal
conditioning to achieve premium performance. Operating on a nominal ±15VDC supply, the DC-EC Series
delivers an extremely linear, low noise, yet high frequency response ±10VDC output.
Innovative design and manufacturing techniques further enhance the DC-EC performance and cost efficiency.
The micro-miniature components employed were meticulously selected for maximum stability and thermal
performance. Vacuum encapsulation of all elements affords excellent shock and vibration tolerance, while
double magnetic shielding provides the utmost protection from stray fields.
Like in most of our LVDTs, the DC-EC windings are vacuum impregnated with a specially formulated, high
temper ature, flexib le resin, and the c oil ass embly is po tted insi de its hous ing with a two-com ponent ep oxy. This
provides ex cell ent pr otection against hos ti le en viro nments suc h as high hum idity, vibration and sh ock.
Available in a variety of stroke ranges from ±0.05 to ±10 inches, the DC-EC Series can be configured with a
number of standard options including metric threaded core, guided core and small diameter/low mass core.
Captive core option: The DC-EC features an optional captive core design (available for most models) that
greatl y sim plifies insta llati on. T he cor e rod an d bear in g assem bl y includes a Bronze bearing on the front end for
self-alignment, while a PTFE sleeve allows low-friction travel through the stainless steel boreliner (spool tube).
The core rod and the bearing assembly are both field serviceable.
Also see our other LVDTs with built-in signal conditioning: DC-SE (single-ended DC voltage), HCD (Hermetically
sealed, ±DC vo lta ge) , HC-485 (RS485 digital output), and the HCT (4-20mA, 2-wire loop).
Measurement Specialties, Inc. (NASDAQ MEAS) offers many other types of sensors and signal conditioners.
Data sheets can be downloaded from our web site at: http://www.meas-spec.com/datasheets.aspx
MEAS ac qu ired Sc haevitz Sensors and the SchaevitzTM trademark in 2000.
FEATURES APPLICATIONS
•
•
Shock and vibration tolerant
•
Z-axis position feedback for punch-presses
•
(avail abl e on select models)
•
Microscope X-Y stage position control
•
AISI 400 Series stainless steel housing
•
•
•
Automotive suspension testing
•
Calibration certificate supplied with each unit
•