Features:
Flexible upgrade path to 40 channels
Flat pass band design
0.22nm clear pass band
Low loss (<5.8dB)
High adjacent channel isolation
-5 to 70°C operating temperature
Compact size (135x18x19mm)
Band loss adjustment
0 to 5 Vdc VOA control
Telcordia GR-1221 qualified
RoHS compliant
Options:
Ribbon connectors
Uniform loss or matched mux/demux loss
Tap/detector before and/or after VOA
Without 10-skip-0 filter
Rack mount or LGX enclosure
Applications:
Metro and long-haul mux/demux
OADM nodes
Subsystem building block
Data Sheet
1
Bookham offers a high performance 10 channel optical
add/drop multiplexer solution for 100GHz channels.
This module’s express port allows an upgrade path to 40
channels. Electronic variable optical attenuators (VOAs) with
tap/detectors are included for band-by-band loss adjustment.
The Bookham 10 channel solution offers an ideal combination
of low loss, compact size, wide channel pass bands and an
upgrade path to 40 channels. Specified loss of <5.8dB is
achieved in the uniform loss version of the product. Matched
mux-demux pairs are also available as a design option.
Ribbon connector outputs are available as a design option.
Thin film technology provides a flat-topped pass band design
that allows for less stringent control of the laser wavelength
over the system lifetime.
These flexible upgrade modules use the Bookham 10-skip-0
banded upgrade port. The 10-skip-0 filter passes ten 100GHz
spaced channels to the ITU channel filters. The same filter
reflects all remaining channels onto the express port with very
low loss. Modules can be cascaded to form20, 30, or 40
channel filter solutions.
10 Channel Optical Add/Drop Multiplexer with
Band VOAs
Data Sheet
2
Functional Diagram
Example of typical module configuration
Z + 2
Z + 3
Z + 4
Z + 5
Z + 6
Z + 7
Z + 8
Z + 9
10 drop channels
Z + 7
Z + 6
Z + 5
Z + 4
Z + 3
Z + 2
Z + 1
Z
Z + 8
Z + 9
Z
Z + 1
10-skip-0
Tap/Det 2
Tap/Det 1
VOA 1
10-skip-0
Tap/Det 4
Tap/Det 3
VOA 2
10 add channels
Demux Express
Demux Common
Mux Express
Mux Common
Module Parameters Region Measure from => to Specification Unit
Number of Channels 10
Channel Spacing 100 GHz
Channel Frequency option 20 ITU Z to ITU Z+9 GHz
Passband Region ITU ± 0.11 nm
Insertion Loss [1] Passband Common => Ports 1-10 5.8 Max dB
Common => Express 0.9 Max dB
IL Variation Passbands Common => Ports 1-10 0.5 Max dB
Channel to Channel Variation Passband Common => Ports 1-10 1.0 Max dB
Isolation Adj Ch Common => Ports 1-10 25 Min dB
Non-Adj Ch Common => Ports 1-10 40 Min dB
Add/Drop Common => Express 13 Min dB
Return Loss 45 Min dB
Polarization Dependant Loss 0.25 Max dB
Polarization Mode Dispersion 0.4 Max ps
Power Handling 300 Min mW
Operating Temperature -5 to 70 °C
Storage Temperature -40 to 85 °C
Dimensions 135x81x19 mm
[1] Losses include connectors, taps and VOAs at minimum attentuation.
VOA Parameters Specification Unit
VOA Mode Normally Dark
Attenuation Range 30 min dB
Response Time 10 max ms
Control Voltage 5 max Vdc
Minimum Attenutaion Voltage 4.7 + 0.3 Vdc
Tap/Detector Parameters Specification Unit
Tap Ratio 5/95
Responsivity 45 min uA/m W
Linearity +10 %
Operating Bias Voltage 5 V
10 Channel Add/Drop Multiplexer with Band VOAs; 100GHz Channels
Specifications (valid over operating temperature)
Data Sheet
Important Notice
Performance figures, data and any illustrative material
provided in this data sheet are typical and must be
specifically confirmed in writing by Bookham before
they become applicable to any particular order or
contract. In accordance with the Bookham policy of
continuous improvement specifications may change
without notice. The publication of information in this
data sheet does not imply freedom from patent or other
protective rights of Bookham or others. Further details
are available from any Bookham sales representative.
Contact Information
BH12936 Rev 2.0 March 2007
©Bookham 2005. Bookham is a registered trademark of Bookham Inc.
RoHS Compliance
Bookham is fully committed to environment
protection and sustainable development and
has set in place a comprehensive program
for removing polluting and hazardous
substances from all of its products.
The relevant evidence of RoHS compliance
isheld as part of our controlled
documentation for each of our compliant
products. RoHS compliance parts are
available to order, please refer to the ordering
information section for further details.
North America
Santa Rosa Office
3640 Westwind Boulevard
Santa Rosa
CA 95403
USA
Tel: +1 707 636 1100
Fax: +1 707 636 1199
www.bookham.com
sales@bookham.com
Europe
Paignton Office
Brixham Road
Paignton
Devon
TQ4 7BE
United Kingdom
Tel: +44 (0) 1803 66 2000
Fax: +44 (0) 1803 66 2801
Asia
Shenzhen Office
2Phoenix Road
Futian Free Trade Zone
Shenzhen 518038
China
Tel: +86 755 33305888
Fax: +86 755 33305805
+86 755 33305807
Ordering Information:
MC1C10_ _0292
Channel Plan
Band (THz) Channel Plan
192.0 to 192.9 20
193.0 to 193.9 30
194.0 to 194.9 40
195.0 to 195.9 50
Partnumbers may change depending on optional configurations chosen
including connectors, pigtails, tap ports and final optical function.
3
}