CXA-0377 (10W DUAL OUTPUTS WITH DIMMING FUNCTION)
DC- AC INVERTER UNIT
CXA E VER, 2004/05/26 CTGB8V046-AAll specification are subject to change without notice.
Applicable LCD:
LQ150X1LGN2A (SHARP)
FEATURES:
TEMPERATURE & HUMIDITY:
Operating Temperature Range 0°C ~ +70°C
Storage Tempreture Range -30°C ~ +85°C
Humidity 95%RH max
DIMENTIONS:
Note1 : Please keep minimum 2mm clearance (all directions) between high voltage area as marked on
mechanical drawing and any conductors.
2
3
1
TOP VIEW
Unit:mm
Weight:50g typ.
SIDE VIEW
9.5 Max
(1.0)
3-φ3.5±0.15
130±0.5
40±0.5
32±0.3
4±0.5
4±0.5 54±0.3 68±0.3
CXA-0377
ES3 @3X14X
MADE IN JAPAN
Label (Examlpe)
Item Name, Date Code,
Origin country
55mm
a:(High Voltage generation area)
SILICONE
a. This inverter is for two lamps. It has Dimming function(PWM System) and Remote function.
b. This product has shutdown function.
It prevents from keeping generating the high voltage when the lamps open.(Refer Note.6.)
c. With lamp failure detector.
Normal Operation : CN1-6=0V
Some Lamps Open : CN1-6=5V
d. Select the way of dimming (CN1-5)
1. Insert a potentiometer (0-10k)
2. Apply the voltage (0-2.5V)
e. The high-voltage area (terminals and patterns) is coated with silicone so as to avoid the defects caused by dust.
CXA-0377 (10W DUAL OUTPUTS WITH DIMMING FUNCTION)
DC- AC INVERTER UNIT
CXA E VER, 2004/05/26 CTGB8V046-AAll specification are subject to change without notice.
ELECTRICAL CHARACTERISTICS:
Symbol
Iin1
F1
F2
Vst
Parameter
Output Current
Input Current
Frequency
Frequency (Duty)
Alarm Signal
-
60
-
min.
4.0
1.5
3.5
1.8
55
-
1.2
65
240
max.typ.
5.55.0
3.52.5
5.54.5
A
kHz
Hz
V
mArms
mArms
200 / 200
200 / 200
0
0
2.5
5±0.25
5±0.25
5±0.25
Ta(°C)Vbr(V)Vrmt(V)Vin(V)
05±0.25
05±0.2512.0±1.2
2.55±0.25
RL2 Open
Max Brightness
Min Brightness
Unit Note
Conditions
Iout1/2 12.0±1.2
12.0±1.2
12.0±1.2
12.0±1.2
12.0±1.2
No. Part Description Qty. Material
PWB 1 Conposite (CEM-3)
t=1.0mm
Input Connector 1 -
Output Connector 2 -
CN2:SM02B-BHSS-1 (JST)
S7B-PH-SM3(JST)
SM02B-BHSS-1(JST)
Symbol
Vhigh1
Vlow1
Pin
CN2-1
CN2-2
Note
1000Vrms / 4.5mArms
CN01:S7B-PH-SM3 (JST)
Note
10.8~13.2V
0V
Symbol
Vin
GND
Pin
CN1-1
CN1-2
CN1-3
CN1-4
Input Voltage
Ground
1
2
3
0~0.4V : OFF
2.5~Vin : ON
VrmtCN1-7 Remote Control
0~2.5VVbr
CN1-5 Brightness Control
0~10kRbr
0V / 5VVst Alarm Signal
CN1-6
(Note2)
(2V)
CN3:SM02B-BHSS-1 (JST)
Symbol
Vlow1
Vlow2
Pin
CN3-1
CN3-2
Note
1000Vrms / 4.5mArms
(2V)
Note2 : This is an output pin and it is active high(5V) if any Lamp opens / fails.
CONNECTOR CONFIGURATION:
-1-mA012.0±1.2
RL1 / RL2(k)
0~70
0~70
0~70
0~70
0~70
0~70
0~70
0~2.5 Remote OFF
Using connector
-
Correspoding connector
Using connector
PHR-7(JST)
BHSR02VS-1(JST)
200 / 200
200 / 200
200 / 200
200 / 200
/ 200
Iin2
12.0±1.2 5±0.25
200 /
-0.50V05±0.25 Normal12.0±1.2 0~70 200 / 200
4.0 5.55.0 V RL1 Open0 0~70
Specification
Dimming with voltage
Dimming with Resistor
Symbol
Iin1
F1
F2
Vst
Parameter
Output Current
Input Current
Frequency
Frequency (Duty)
Alarm Signal
-
60
-
min.
4.0
1.5
3.5
1.8
55
-
1.2
65
240
max.typ.
5.55.0
3.52.5
5.54.5
A
kHz
Hz
V
mArms
mArms
200 / 200
200 / 200
0
0
10
5±0.25
5±0.25
5±0.25
Ta(°C)Rbr(k)Vrmt(V)Vin(V)
05±0.25
05±0.2512.0±1.2
105±0.25
RL2 Open
Max Brightness
Min Brightness
Unit Note
Conditions
Iout1/2 12.0±1.2
12.0±1.2
12.0±1.2
12.0±1.2
12.0±1.2
-1-mA012.0±1.2
RL1 / RL2(k)
0~70
0~70
0~70
0~70
0~70
0~70
0~70
0~10 Remote OFF
200 / 200
200 / 200
200 / 200
200 / 200
/ 200
Iin2
12.0±1.2 5±0.25
200 /
-0.50V05±0.25 Normal12.0±1.2 0~70 200 / 200
4.0 5.55.0 V RL1 Open0 0~70
Specification
CXA-0377 (10W DUAL OUTPUTS WITH DIMMING FUNCTION)
DC- AC INVERTER UNIT
CXA E VER, 2004/05/26 CTGB8V046-AAll specification are subject to change without notice.
TEST CIRCUIT:
RL1,2 : Load resistance (7W MIN.)
Note 7. Connection diagram of LCD module (Reference)
*Connect the High Frequency Current Meter to the
Low-Voltage (VLOW) side.
SW1
a
b
OPEN
Operation of Unit
Operation
Non Operation
Non Operation
Note 4. SW1(ON/OFF) Operation is as following;
SW2
a
b
Operation of Unit
Voltage dimming
Vbr=0~2.5V
(Vbr=0V : Max Brightness)
Variable resistance dimming
Rbr=0~10k
(Rbr=0 : Max Brightness)
Note 5. SW2(ON/OFF) Operation is as following;
Note 6.Safety Function
Load Condition
Normal Operation
1 Lamp Open
(CN2 or CN3 Open)
2 Lamps Open
(CN2 and CN3 Open)
*1Alarm Signal
(CN1-6)
0.5V max.
4.0~5.5V
4.0~5.5V
*2Shutdown
Operation
Normal
Normal
Shutdown
In test circuit ,If CN2 or CN3 opens,
then the warning signal will be activated (+5V).
If the inverter detects open circuit all lamps
for more than 3 seconds it will shut down.
*1.
*2.
RL1 A
Io1
T1
CN2-2
Vlow1
CN2-1
Vhigh1
CN1-3.4
GND
Vin
10.8`13.2V
Iin
CN1-1.2
Vin
V
A
V
CN1-6
Vst
SW1
Vrmt
0/5V
CN1-7
Vrmt
a
b
FF
RL2 A
Io2
T2
CN3-2
Vlow2
CN3-1
Vhigh2
Vopen V
1000:1
PROBE
Fduty F
IC3
* Please do not open
this terminal (CN1-5).
*Vbr
0~2.5V
a
b
SW2
Rbr
0~10k
(1/4W~)
V
*CN1-5
Vbr
A
A
VHIGH
VLOW
VHIGH
VLOW
LCD module
DC-AC
Inverter