Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi 32328895 Issue B Datasheet FEATURES * Pressure range of 6 bar to 550 bar | 50 psi to 8,000 psi * 0.25% full scale accuracy Best Fit Straight Line (BFSL) * Total Error Band (TEB) as low as 2 %FSS * Compensated and operating temperature range of -40C to 125C [-40F to 257F] (see Table 4) * Less than 2 ms response time * Fully temperature compensated, calibrated and amplified * Rated IP65 or better for protection from most harsh environments * RoHS, CE, UL Component Recognition for USA and Canada: File No. E258956 DESCRIPTION The MLH Series Heavy Duty Pressure Transducers combine Application Specific Integrated Circuit (ASIC) technology with a media-isolated, metal diaphragm design. This digitally compensated transducer offers value and performance, making it a suitable pressure sensing solution for demanding applications. Industry standard electrical connectors and pressure ports are offered for enhanced reliability and user flexibility. The MLH Series has six standard output options: * Ratiometric: 0.5 Vdc to 4.5 Vdc from 5 Vdc excitation * Current: 4 mA to 20 mA * Regulated: 1 Vdc to 6 Vdc * Regulated: 0.25 Vdc to 10.25 Vdc * Regulated: 0.5 Vdc to 4.5 Vdc * Regulated: 1 Vdc to 5 Vdc VALUE TO CUSTOMERS * Total Error Band (TEB) as low as 2 %FSS from -40C to 125C: Provides indication of the transducer's true measurement performance over a specified temperature range; small error promotes system uptime and efficiency. (See Figure 1.) * All metal wetted parts allow for potential use in a wide variety of fluid applications. * No internal elastomeric seals eliminate O-ring compatibility issues. * Amplified outputs reduce the need to purchase external amplifiers. * Input reverse voltage protection guards against mis-wiring. * Less than 2 ms response time provides more accurate, high speed measurement. Sensing and Internet of Things POTENTIAL APPLICATIONS * Industrial: Compressors, cylinder tank pressure, HVAC, hydraulics, oil and gas, refrigeration, water distribution * Transportation: Multiple applications including braking and alternative fuels * Medical: Anesthesia delivery machines, blood analyzers, chemistry analyzers, gas chromatography, oxygen concentrators, and ventilators PORTFOLIO The MLH Series joins the PX3 Series, PX2 Series, SPT Series heavy duty pressure transducers and the 13 mm Series and 19 mm Series heavy duty pressure transducers. Figure 1. Total Error Band (TEB) Definition Sources of Error Offset Full Scale Span Pressure Non-Linearity Pressure Hysteresis Pressure Non-Repeatability Thermal Effect on Offset Thermal Effect on Span Thermal Hysteresis Accuracy BFSL Total Error Band Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Table 1. Pressure Range Specifications1 (At 25C [77F] and at rated excitation unless otherwise specified.) bar psi Operating Pressure Proof Pressure Burst Pressure Operating Pressure Proof Pressure Burst Pressure2 6 18 60 50 150 500 10 30 100 100 300 1000 16 48 160 150 450 1500 25 75 250 200 600 2000 40 80 400 250 750 2500 60 120 600 300 900 3000 100 200 1000 500 1500 5000 160 320 1600 1000 2000 10000 250 500 2068 2000 4000 20000 350 700 2068 3000 6000 30000 500 750 2068 5000 7500 30000 550 825 2068 8000 12000 30000 Comparable metric units follow same proof and burst specifications. 2 Bonded washer seal used on G 1/8 (DIN 3852-2) port is limited to 25000 psi burst. 1 Table 2. Electrical Specifications (At 25C [77F] unless otherwise noted.) Output Signal Characteristic Zero output Ratiometric A Current B Regulated C Regulated D Regulated E Regulated G 0.5 Vdc 4 mA 1 Vdc 0.25 Vdc 0.5 Vdc 1 Vdc 5 Vdc (1 Vdc to 6 Vdc) 10 Vdc (0.25 Vdc to 10.25 Vdc) 4 Vdc (1 Vdc to 5 Vdc) 5 Vdc (6 Vdc max.)1 9.5 Vdc to 30 Vdc2 8 Vdc to 30 Vdc2 14 Vdc to 30 Vdc2 4 Vdc (0.5 Vdc to 4.5 Vdc) 7 Vdc to 30 Vdc2 4 mA typ., 8 mA max. N/A 5 mA typ., 17 mA max. 5 mA typ., 17 mA max. 5 mA typ., 17 mA max. 5 mA typ., 17 mA max. Source (nominal) 1 mA N/A 1 mA 1 mA 1 mA 1 mA Sink (nominal 1 mA at zero output N/A A1 mA at zero output 1 mA at zero output 1 mA at zero output 1 mA at zero output 90 dB 90 dB 90 dB 90 dB 90 dB 90 dB 25 Ohm max. N/A 25 Ohm max. 25 Ohm max. 25 Ohm max. 25 Ohm max. Full scale span (FSS) Excitation Supply current 4 Vdc 16 mA (0.5 Vdc to 4.5 Vdc) (4 mA to 20 mA) Supply rejection ratio Output impedance 1 2 8 Vdc to 30 Vdc2 Maintains ratiometricity at 5 0.25 Vdc excitation. Product can tolerate 6 Vdc excitation without damage. See Figures 2 and 3 for more information regarding maximum excitation voltage vs. operating temperature. Table 3. Pressure Reference Types Pressure Reference Sealed gage1 Description Output is proportional to the difference between applied pressure and a built-in fixed reference to 1 atmA, where the minimum operating pressure is set to 14.7 psiA (1 atmA). Transducer measures pressure relative to ambient pressure. Output is proportional to the difference Vented gage (relative) 2 between applied pressure and atmospheric (ambient) pressure, where the minimum operating pressure is set to atmospheric pressure. 2 Sensing and Internet of Things Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Table 4. Environmental and Mechanical Specifications (At 25C [77F] unless otherwise noted.) Characteristic Parameter Material in contact with media: port diaphragm stainless steel 304L Haynes 214 alloy Housing material black plastic - Amodel AS-4133 HS - PPA Weight (typical for Metri-Pack 150 and 1/8 NPT pressure port types) 57.0 g [2.0 oz] Shock 100 g peak [11 ms] Vibration MIL-STD-810C, Figure 514.2-5, Curve AK, Table 514.2-V, Random Vibration Test (overall g rms = 20.7 min.) Compensated and operating temperature range: 0.5 Vdc to 4.5 Vdc ratiometric output all regulated and 4 mA to 20 mA outputs -40C to 125C [-40F to 257F] -40C to 125C [-40F to 257F] (See Figures 2 and 3 for operating area details.) Storage temperature range -40C to 125C [-40F to 257F] Approvals RoHS, CE, UL Component Recognition for USA and Canada: File No. E258956 Table 5. Performance Specifications (At 25C [77F] unless otherwise noted.) Characteristic Parameter Response time <2 ms Accuracy : >100 psi <100 psi 0.25 %FSS 0.50 %FSS 1 Total Error Band2: Vented gage (relative): <300 psig >300 psig Sealed gage: without L, M, P electrical connector types: 100 psis to 299 psis (-40C to 85C [-40F to 185F]) 100 psis to 299 psis (>85C to 125C [>185F to 257F]) >300 psis (-40C to 125C [-40F to 257F]) with L, M, P electrical connector types: 100 psis to 299 psis (-40C to 65C [-40F to 149F]) 100 psis to 299 psis (>65C to 125C [>149F to 257F]) >300 psis (-40C to 65C [-40F to 149F]) >300 psis (>65C to 125C [>149F to 257F]) 3 %FSS 2 %FSS 3 %FSS 10 %FSS 2 %FSS 10 %FSS 15 %FSS 5 %FSS 15 %FSS Includes pressure non-linearity (BFSL), pressure hysteresis and pressure non-repeatability. Thermal errors are not included. (See Figure 1.) 2 Includes offset error, full scale span error, pressure non-linearity (BFSL), pressure hysteresis, pressure non-repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis. (See Figure 1.) 1 Sensing and Internet of Things 3 Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Operating Temperature (C) Figure 2. Regulated Output Operating and Temperature Compensation 125 124 123 122 121 120 119 118 117 116 Operating and temperature compensated area for regulated output 6 8 10 12 14 16 18 20 22 24 26 28 30 Supply Voltage (Vdc) Note: The dot indicates the maximum operating temperature of 125C [257F] with a 24 V supply. Operating Temperature (C) Figure 3. Current Output Operating and Temperature Compensation 125 120 115 110 105 100 95 90 85 80 75 70 65 60 10 Ohm load 250 Ohm load Operating and temperature compensated area for current output 6 8 10 12 14 16 18 20 22 24 26 28 30 Supply Voltage (Vdc) Note: The operating area is extended with a 250 Ohm resistor. Higher loads extend the operating area. The dot indicates the maximum operating temperature when using a 24 V supply and a 250 Ohm resistor. CAUTION PRODUCT DAMAGE DUE TO MECHANICAL ISSUES * Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating materials and thread sealants can result in significantly different torque values from one application to the next.) * When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling. Ensure the sealant is rated for the application. * Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers. * Always hand-start transducers into the hole to prevent cross threading and damage. * Ensure that torque is not applied to the electrical connector. * Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals can compromise ingress protection, leading to short circuits. Failure to comply with these instructions may result in product damage. CAUTION PRODUCT DAMAGE DUE TO PARTICULATES * Ensure that a filter is used upstream of the transducer to keep media flow free of larger particulates and increased humidity. All MLH Series transducers are dead-ended devices; particulate accumulation and condensing moisture may affect transducer output. * It is recommend that the transducer be positioned with the port facing downwards; any particulates in the system are less likely to enter and settle within the pressure transducer if it is in this position. * Ensure that the media does not create a residue when dried. Build-up inside the transducer may affect transducer output; rinsing of a dead-ended transducer is potentially difficult and has limited effectiveness in removing residue. Failure to comply with these instructions may result in product damage. 4 Sensing and Internet of Things Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Figure 4. Nomenclature and Order GuideE For example, MLH150PSB01B defines an MLH Series Heavy Duty Pressure Transducer, 150 psi pressure range, sealed gage pressure reference, Metri-Pack 150 electrical connector type, 1/4-18 NPT pressure port type, 4 mA to 20 mA output. MLH 150 P S B 01 B Output Transfer Function Series Heavy Duty Pressure Transducer1 MLH Pressure Range bar 006 010 016 025 040 060 100 160 250 350 500 550 6 10 16 25 40 60 100 160 250 350 500 550 psi 050 100 150 200 250 300 500 01K 02K 03K 05K 08K Electrical Connector Type 50 100 Metri-Pack 1503 150 200 250 300 B Cable harness, 1 meter cable length3 L bar P psi 01 B C D E G Current: 4 mA to 20 mA Regulated: 1 Vdc to 6 Vdc Regulated: 0.25 Vdc to 10.25 Vdc Regulated: 0.5 Vdc to 4.5 Vdc Regulated: 1 Vdc to 5 Vdc 1/4-18 NPT (ANSI B1.20.1) 54 M10x1 with O-ring seal (ISO 6149-2)5 500 1000 2000 Hirschmann 3000 5000 8000 Pressure Reference G Vented gage (relative) S Ratiometric: 0.5 Vdc to 4.5 Vdc from 5 Vdc excitation Pressure Port Type C Cable harness, 3 meter cable length33 M 06 09 Unit B A M12x1 (Brad Harrison micro) Flying leads D 13 P Sealed gage2 19 DIN 43650-C, 8 mm male Metri-Pack 150 mating connector3 11 G 50 Deutsch DTM04-3P (integral) 51 1/8-27 NPT (ANSI B1.20.1) 55 7/16-20 UNF 1/4 in 45 Flare Female Schrader with depressor 56 1/2-14 NPT (ANSI B1.20.1) 57 R 1/4-19 BSPT (ISO 7-1) 58 R 1/8-28 BSPT (ISO 7-1) 59 3/8-24 UNF with O-ring seal (SAE J1926-2)5 7/16-20 UNF with O-ring seal (SAE J1926-2)5 M12x1.5 with O-ring seal (ISO 6149-2)5 M14x1.5 with O-ring seal (ISO 6149-2)5 M16x1.5 with O-ring seal (ISO 6149-2)5 M18x1.5 with O-ring seal (ISO 6149-2)5 M20x1.5 with O-ring seal (ISO 6149-2)5 60 G1/8-28 BSPP with bonded washer (DIN 3852-2)5, 6 61 G1/4-19 BSPP with bonded washer (DIN 3852-2)5, 6 62 G1/8-28 BSPP with elastomeric seal (ISO 1179-2)5 63 G1/4-19 BSPP with elastomeric seal (ISO 1179-2)5 AMP Superseal 1.54 T 52 1/2-20 UNF with O-ring seal (SAE J1926-2)5 H 53 9/16-18 UNF with O-ring seal (SAE J1926-2)5 Not all catalog listing combinations are available. Custom products are available. Please contact Honeywell. Sealed gage option is only available in pressure ranges at or above 8 bar | 100 psi. Metri-Pack 150 mating connectors with shielded cable and 22 AWG wire are available from Honeywell. Order part no. 3685301 for 1 m [3.2 ft] cable length and part no. 3685302 for 3 m [9.8 ft] cable length. 4 Available with Output Transfer Function A only. 5 Seal accessory is included with the sensor. Seal accessory materials and specifications are: O-ring (nitrile, durometer 90, temperature range -30C to 125C), bonded washer (steel outer ring with nitrile inner ring, temperature range -30C to 125C), elastomeric seal (nitrile, temperature range -30C to 125C). 6 When using the bonded washer accessory supplied by Honeywell, the customer's female port connection design should follow DIN 3852-1: 2000-11 size large. If compliance to DIN 3852-1:2014-05 is required, contact Honeywell for alternate options. 1 2 3 Sensing and Internet of Things 5 Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Figure 5. Electrical Connector Type Mounting Dimensions (For reference only. mm/[in].) General product marking "H" + "P" = total nominal product length Catalog listing 27,0 Hex flat to flat [1.06] Date code "P" "H" B C D G Metri-Pack 150 Hirschmann M12x1 (Brad Harrison micro) DIN 43650-C, 8 mm male Connector: Delphi 12078088 Mating connector: Delphi 12110192 IP rating1: IP65 (all versions) Connector: Hirschmann G series, 4-pole (small cubic connector) Mating connector: Hirschman G4WF or equivalent IP rating1: IP65 (all versions) Connector: DS/EN 61076-2101 (IEC 61076-2-101) Mating connector: 4 POS Type D IP rating1: IP65, IP67 (sealed gage versions), IP65 (vented gage versions) Connector: DIN 43650C, 8 mm Mating connector: DIN 43650C, 8 mm IP rating1: IP65 (all versions) Pin Voltage Output (3-wire) Current Output (2-wire) Pin Voltage Output (3-wire) Current Output (2-wire) Pin Voltage Output (3-wire) Current Output (2-wire) Pin Voltage Output (3-wire) Current Output (2-wire) A +excitation +excitation 1 no connection no connection 1 +excitation +excitation 1 +excitation +excitation B common no connection 2 output no connection 2 common -excitation (return) 2 common -excitation (return) C output -excitation (return) 3 common -excitation (return) 3 output no connection 3 4 +excitation +excitation 4 no connection no connection 4 no no connenction connection output Pin C Pin B Pin A Pin 3 Pin 1 Pin 4 Pin 4 Pin 3 Pin 2 No connection Pin 2 Pin 2 Pin 1 Pin 3 Pin 1 Pin 4 o16,51 17,0 [0.67] [0.46] o16,0 o10,0 [0.63] "H" = 41,7 [1.64] 6 Hole (Vented gage versions only) Sensing and Internet of Things no connection "H" = 32,6 [1.28] [0.39] Hole (Vented gage versions only) "H" = 33,5 [1.32] Hole (Vented gage versions only) "H" = 30,1 [1.19] Hole (Vented gage versions only) Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Figure 5. Electrical Connector Type Mounting Dimensions (continued) L H AMP Superseal 1.5 T P Cable Harness, 1 Meter M Deutsch DTM04-3P (integral) Flying Leads Cable Harness, 3 Meter Connector: Amp 282087 Mating connector: Amp 282087 IP rating1: IP65 (all versions) Connector: 24 AWG with TPE jacket Mating connector: Flying leads IP rating1: IP65, IP67, IP69K (sealed gage versions), IP65 (vented gage versions) Pin Voltage Output (3-wire) Wire Color 1 common red 2 output white 3 +excitation Voltage Output (3-wire) Current Output (2-wire) +excitation +excitation black output common Connector: DTM04-3P Mating connector: DTM063S with wedgelock WM-3S IP rating1: IP65, IP67, IP69K (sealed gage versions), IP65 (vented gage versions) Connector: 6 in flying leads with 20 AWG wire and PE insulation IP rating1: IP65, IP67, IP69K (sealed gage versions), IP65 (vented gage versions) Wire Color red -excitation white (return) no connection (black wire black removed) Voltage Output (3-wire) Current Output (2-wire) Voltage Output (3-wire) Pin Current Output (2-wire) +excitation +excitation 1 +excitation +excitation common -excitation (return) 2 common -excitation (return) output no connection (black wire removed) 3 output no connection White Pin 3 Black (Used for voltage ouptut only) White Red Pin 1 Pin 2 Pin 2 Black (Used for voltage ouptut only) Pin 1 13,8 [0.54] "H" = 41,0 [1.61] 1 2 13,4 [0.53] [0.43] [0.43] "H" = 35,3 [1.39] Pin 3 o10,8 o10,8 Hole (Vented gage versions only) Red Hole (Vented gage versions only) "H" = 35,3 [1.39] "H" = 42,6 [1.68] Hole (Vented gage versions only) Hole (Vented gage versions only) IP rating is determined by the electrical connector type chosen. Three-wire cable is required for ratiometric and regulated voltage outputs; two wire cable is required for current output. Sensing and Internet of Things 7 Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Figure 6. Pressure Port Type Mounting Dimensions (For reference only: mm/[in].)1 General product marking "H" + "P" = total nominal product length Catalog listing 27,0 Hex flat to flat [1.06] "P" "H" 01 15,2 [0.60] 11 20,1 [0.79] 50 3/8-24 UNF (SAE J1926-2) Seal1: O-ring Mating geometry: SAE J1926-1 Installation torque: 10 N m [7.4 ft-lb] 13,5 [0.53] 53 9/16-18 UNF (SAE J1926-2) Seal1: O-ring Mating geometry: SAE J1926-1 Installation torque: 45 N m [33.2 ft-lb] 8 "P" = 15,0 [0.59] 10,2 [0.40] 16,0 [0.63] Sensing and Internet of Things 14,7 [0.58] 51 7/16-20 UNF (SAE J1926-2) Seal1: O-ring Mating geometry: SAE J1926-1 Installation torque: 20 N m [14.8 ft-lb] "P" = 19,8 [0.78] 15,0 [0.59] 54 M10x1.0 (ISO 6149-2) Seal1: O-ring Mating geometry: ISO 6149-2 Installation torque: 20 N m [14.8 ft-lb] "P" = 15,9 [0.63] "P" = 17,5 [0.69] 12,7 [0.50] 19 Seal: Pipe thread Mating geometry: ISO 7-1 Installation Torque: 2 to 3 turns from finger tight "P" = 19,6 [0.77] Seal: 45 cone Mating geometry: SAE J512 Installation torque: 20 Nm [14.8 ft-lb] R1/8-28 (BSPT) R1/4-19 (BSPT) Seal: Pipe thread Mating geometry: ANSI B1.20.1-2013 Installation Torque: 2 to 3 turns from finger tight "P" = 20,8 [0.82] Seal: Pipe thread Mating geometry: ANSI B1.20.1-2013 Installation torque: 2 to 3 turns from finger tight 13 1/2-14 NPT "P" = 18,3 [0.72] 7/16-20 UNF 1/4 in 45 Flare Female Schrader with depressor 1/8-27 NPT Seal: Pipe thread Mating geometry: ANSI B1.20.1-2013 Installation torque: 2 to 3 turns from finger tight "P" = 24,9 [0.98] 09 06 1/4-18 NPT "P" = 20,1 [0.79] Date code 11,1 [0.44] Seal: Pipe thread Mating geometry: ISO 7-1 Installation Torque: 2 to 3 turns from finger tight "P" = 15,0 [0.59] 10,2 [0.40] 52 1/2-20 UNF (SAE J1926-2) Seal1: O-ring Mating geometry: SAE J1926-1 Installation torque: 40 N m [29.5 ft-lb] "P" = 19,8 [0.78] 15,0 [0.59] 55 M12x1.5 (ISO 6149-2) Seal1: O-ring Mating geometry: ISO 6149-2 Installation torque: 45 N m [33.2 ft-lb] "P" = 18,3 [0.72] 13,5 [0.53] Heavy Duty Pressure Transducers MLH Series, 6 bar to 550 bar | 50 psi to 8000 psi Figure 6. Pressure Port Type Mounting Dimensions (continued) 56 M14x1.5 (ISO 6149-2) Seal1: O-ring Mating geometry: ISO 6149-1 Installation torque: 45 N m [33.2 ft-lb] "P" = 18,3 [0.72] 13,5 [0.53] 59 M20x1.5 (ISO 6149-2) Seal1: O-ring Mating geometry: ISO 6149-1 Installation torque: 80 N m [59.0 ft-lb] 57 "P" = 19,8 [0.78] o8,4 [0.33] Seal1: Bonded washer Mating geometry with bonded washer: DIN 3852-1:2000-11, large Installation torque: 50 N m [36.9 ft-lb] "P" = 19,0 [0.75] o11,9 [0.47] 1,0 [0.04] 1 14,1 [0.56] 9,7 [0.38] 2,0 [0.08] 2,0 [0.08] Bonded washer Bonded washer o10,4 o15,9 [0.41] [0.63] o13,7 [0.54] Bonded washer o20,6 [0.81] 63 G1/4-19 (BSPP) ISO 1179-2 Seal1: Elastomeric Mating geometry: ISO 1179-1 Installation torque: 50 N m [36.9 ft-lb] "P" = 18,8 [0.74] 9,5 [0.37] 120 61 Seal1: Bonded washer Mating geometry with bonded washer: DIN3852-1; 2000-11, large Installation torque: 20 N m [14.8 ft-lb] 62 Elastomeric seal 16,5 [0.65] G1/4-19 (BSPP) DIN 3852-2 G1/8-28 (BSPP) ISO 1179-2 0,5 [0.02] "P" = 21,3 [0.84] 15,0 [0.59] 60 Bonded washer "P" =14,3 [0.56] Seal1: O-ring Mating geometry: ISO 6149-1 Installation torque: 70 N m [51.6 ft-lb] G1/8-28 (BSPP) DIN 3852-2 16,5 [0.65] Seal1: Elastomeric Mating geometry: ISO 1179-1 Installation torque: 20 N m [14.8 ft-lb] M18x1.5 (ISO 6149-2) Seal1: O-ring Mating geometry: ISO 6149-1 Installation torque: 55 N m [40.6 ft-lb] "P" = 14,6 [0.57] "P" = 21,3 [0.84] 58 M16x1.5 (ISO 6149-2) 14,0 [0.55] Proper assembly of seal to stud end 0,8 [0.03] Proper assembly of seal to stud end Elastomeric seal o11,6 [0.46] 120 o16,5 [0.65] 1,5 [0.06] Seal accessory included with transducer. Seal accessory material and specifications: O-ring (nitrile, durometer 90, temperature range -30 C to 125 C), bonded washer (steel outer ring with nitrile inner ring, temperature range -30 C to 125 C), elastomeric seal (nitrile, temperature range -30 C to 125 C). Sensing and Internet of Things 9 ADDITIONAL INFORMATION The following associated literature is available on the Honeywell web site at sensing.honeywell.com: WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. * Product line guide * Product range guide * Product installation instructions Failure to comply with these instructions could result in death or serious injury. * Product CAD models WARNING MISUSE OF DOCUMENTATION * * The information presented in this datasheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer's sole responsibility to determine the suitability of the product in the application. For more information Honeywell Sensing and Internet of Things services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor, visit sensing.honeywell.com or call: Asia Pacific +65 6355-2828 Europe +44 (0) 1698 481481 USA/Canada +1-800-537-6945 Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. Honeywell Sensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywell.com 32328895-B-EN | B | 03/18 (c) 2018 Honeywell International Inc. All rights reserved.